Safety and efficacy of intracameral mydriatics in cataract surgeryLundberg, Björn January 2008 (has links)
Background: In order to perform cataract surgery, adequate dilatation of the pupil is essential. This is traditionally achieved by preoperative topical mydriatic eye-drops, commonly cyclopentolate and phenylephrine. This routine has several disadvantages. First, the slow penetration through the cornea delays the onset of mydriasis. Second, the limited bioavailability of topically administered substances with significant systemic absorption may increase the risk for systemic side effects. Third, even if good mydriasis is achieved initially with topical mydriatics (TM), the effect tends to wear off during surgery. In relation to cataract surgery a transient postoperative corneal oedema is sometimes noted, indicating effects on the corneal endothelial pump function. These effects have been ascribed to ultrasonic or mechanical trauma from the phacoemulsification procedure. Corneal endothelial cell loss (ECL) is a commonly studied variable, not least because it is associated with the long-term risk for corneal decompensation. But, there has been a debate whether postoperative corneal swelling after phacoemulsification cataract surgery correlates to ECL. Aims: To evaluate an alternative mydriatic regimen for phacoemulsification cataract surgery: intracameral injection of mydriatics mixed with lidocaine (ICM). Additionally, to determine the correlation between early transient postoperative corneal oedema and permanent ECL after phacoemulsification cataract surgery. Methods: Pupil dilatation with ICM (150 µl of lidocaine 1%, phenylephrine 1.5%, and cyclopentolate 0.1%) was compared to TM (phenylephrine 10% and cyclopentolate 1%) prior to cataract surgery. Additionally, two ICM-groups were randomized to receive either 0.6 µg/ml epinephrine added to the irrigating balanced salt solution or no epinephrine in the irrigation solution. Furthermore, two randomized ICM-groups, with or without cyclopentolate, were analyzed. The patients planned for cataract surgery were examined with ultrasonic pachymetry, specular microscope endothelial photography and Orbscan II slit-scan tomography pre- and postoperatively. Results: With ICM, mydriasis reached 95 ± 3% of its final value within 20 seconds. In the ICM-group, the pupils were smaller than in the TM-group (mean 6.7 ± 1.0 mm versus 7.7 ± 1.0 mm, P<.001), but did not contract intraoperatively as the TM pupils did. Conversely, with ICM the pupil sizes generally increased during the cataract procedures. This increase was significantly greater without epinephrine in the irrigating solution (13 ± 19% versus 4 ± 14%; p = 0.02). No significant differences in pupil sizes were observed between the patients who were given ICM with or without cyclopentolate. The central corneal swelling at the first postoperative day was strongly correlated to the central ECL at 3 months, R2 = 0.785, P < 0.001. Conclusions: ICM is a rapid and safe alternative to TM in phacoemulsification cataract surgery. An irrigating solution without epinephrine can safely be used with ICM. Cyclopentolate, administrated intracamerally, has no immediate additive mydriatic effect to intracameral lidocaine combined with phenylephrine. The degree of permanent corneal endothelial damage in cataract surgery is reflected in the degree of early postoperative corneal swelling.
|
2 |
Goldmann and error correcting tonometry prisms compared to intracameral pressureMcCafferty, Sean, Levine, Jason, Schwiegerling, Jim, Enikov, Eniko T. 04 January 2018 (has links)
Background: Compare Goldmann applanation tonometer (GAT) prism and correcting applanation tonometry surface (CATS) prism to intracameral intraocular pressure (IOP), in vivo and in vitro. Methods: Pressure transducer intracameral IOP was measured on fifty-eight (58) eyes undergoing cataract surgery and the IOP was modulated manometrically to 10, 20, and 40 mmHg. Simultaneously, IOP was measured using a Perkins tonometer with a standard GAT prism and a CATS prism at each of the intracameral pressures. Statistical comparison was made between true intracameral pressures and the two prism measurements. Differences between the two prism measurements were correlated to central corneal thickness (CCT) and corneal resistance factor (CRF). Human cadaver eyes were used to assess measurement repeatability. Results: The CATS tonometer prism measured closer to true intracameral IOP than the GAT prism by 1.7+/-2.7 mmHg across all pressures and corneal properties. The difference in CATS and GAT measurements was greater in thin CCT corneas (2.7+/-1.9 mmHg) and low resistance (CRF) corneas (2.8+/-2.1 mmHg). The difference in prisms was negligible at high CCT and CRF values. No difference was seen in measurement repeatability between the two prisms. Conclusion: A CATS prism in Goldmann tonometer armatures significantly improve the accuracy of IOP measurement compared to true intracameral pressure across a physiologic range of IOP values. The CATS prism is significantly more accurate compared to the GAT prism in thin and less rigid corneas. The in vivo intracameral study validates mathematical models and clinical findings in IOP measurement between the GAT and CATS prisms.
|
3 |
Goldmann applanation tonometry error relative to true intracameral intraocular pressure in vitro and in vivoMcCafferty, Sean, Levine, Jason, Schwiegerling, Jim, Enikov, Eniko T. 25 November 2017 (has links)
Background: Goldmann applanation tonometry (GAT) error relative to intracameral intraocular pressure (IOP) has not been examined comparatively in both human cadaver eyes and in live human eyes. Futhermore, correlations to biomechanical corneal properties and positional changes have not been examined directly to intracameral IOP and GAT IOP. Methods: Intracameral IOP was measured via pressure transducer on fifty-eight (58) eyes undergoing cataract surgery and the IOP was modulated manometrically on each patient alternately to 10, 20, and 40 mmHg. IOP was measured using a Perkins tonometer in the supine position on 58 eyes and upright on a subset of 8 eyes. Twenty one (21) fresh human cadaver globes were Intracamerally IOP adjusted and measured via pressure transducer. Intracameral IOP ranged between 5 and 60 mmHg. IOP was measured in the upright position with a Goldmann Applanation Tonometer (GAT) and supine position with a Perkins tonometer. Central corneal thickness (CCT) was also measured. Results: The Goldmann-type tonometer error measured on live human eyes was 5.2 +/- 1.6 mmHg lower than intracameral IOP in the upright position and 7.9 +/- 2.3 mmHg lower in the supine position (p <.05). CCT also indicated a sloped correlation to error (correlation coeff. = 0.18). Cadaver eye IOP measurements were 3.1+/-2. 5 mmHg lower than intracameral IOP in the upright position and 5.4+/- 3.1 mmHg in the supine position (p <.05). Conclusion: Goldmann IOP measures significantly lower than true intracameral IOP by approximately 3 mmHg in vitro and 5 mmHg in vivo. The Goldmann IOP error is increased an additional 2.8 mmHg lower in the supine position. CCT appears to significantly affect the error by up to 4 mmHg over the sample size.
|