Spelling suggestions: "subject:"inverter."" "subject:"converter.""
371 |
Měnič s tranzistory GaN pro elektrický kompresor / Inverter for electric supercharger with GaN transistorsGalia, Jan January 2021 (has links)
This master’s thesis deals with the design and realization of a functional sample power inverter for an electric compressor, which is used in hybrid cars. The electric compressor powered by the inverter is E-compressor by Garrett Advancing Motion. An inverter will be using modern High Electron Mobility Transistors which are based on gallium nitride (GaN). The purpose of this thesis is to find if GaN transistors can be used in E-boosting application.
|
372 |
Svářečka pro obloukové svařovaní se spínaným zdrojem / The inverter for arc-weldingVaculík, Josef January 2011 (has links)
This diplom thesis theoretically deals about principle of pulse welding current source. Work explains operation principle of the single acting transmit converter used in realized construction and mention the others examples of converters types. Goal of the work is design individual parts of source : input filter, pulse transformer, output inductor and power semiconductors components. Thesis also contains description of the regulation circuitry of the converter, auxiliary power supply and pre-driver for power transistors. If everything will be all right prototype of the source will be assembled and measured. Results will be compared with theoretical assumptions.
|
373 |
Design svařovacího aparátu / Design of welding machineTomášková, Veronika January 2011 (has links)
This diploma thesis deals with the development of multifunction welding machine for manual metal arc welding MMA and metal inert/active gas welding MIG/MAG. The goal of this work was to design compactly shaped welding inverter considering ergonomics and technological aspects. The thesis is divided into two parts. First part contains historical progress of arc welding, basic principles of chosen methods and view on contemporary market with welding machines. The second part deals with the development of the design, analysis and options of the final proposal.
|
374 |
Řídicí modul BLDC motoru / BLDC Motor Control ModuleMorávek, Lukáš January 2016 (has links)
Diploma thesis describes design and realization of hardware and software for controlling and regulation of the high-speed drive with BLDC motor, which will serve as a spindle for CNC milling machine. The thesis described in detail the schematic design and the design of printed circuit board of the power part, control part and power supply part of the three-phase transistor inverter controlled by DSP processor. It is also described in detail program of DSP processor for controlling and regulation of the BLDC motors, which the function is verified by the final measurements. The result of Diploma thesis is functional high-speed drive with BLDC motor.
|
375 |
Návrh měniče pro BLDC motor / Design of a convertor for a BLDC motorStejskal, Martin January 2017 (has links)
This master thesis deals with the design and realization of a drive for a 500 W BLDC motor powered with a battery power supply. It also deals with the possibilities of realization of drives and other possibilities to control these motors. Describes the implementation of the inverter using Atmel's AVR microcontroller. The thesis also deals with the design of an auxiliary switching inverter. Communication with UART and CAN interface is also implemented.
|
376 |
Conversor multifuncional conectado à rede elétrica para compensação de oscilações de potência instantânea /Olímpio Filho, José de Arimatéia January 2019 (has links)
Orientador: Helmo Kelis Morales Paredes / Resumo: Esta dissertação de mestrado propõe o desenvolvimento e a implementação de uma estratégia de compensação para conversores eletrônicos de potência (CEP) multifuncionais conectados à rede elétrica. A geração dos sinais de referência de corrente para o conversor multifuncional é obtida através das grandezas conservativas da CPT, do inglês Conservative Power Theory. O CEP proposto neste trabalho desempenha o papel de um conversor interface de rede no modo conectado, tendo como finalidade a mitigação de oscilações de potência instantânea bem como injeção de potência ativa na rede elétrica, caracterizando assim o seu aspecto multifuncional. São realizados estudos teóricos e simulações computacionais com o intuito de validar a estratégia proposta. Para tanto, foram identificadas as parcelas indesejadas de corrente que permitam a compensação das componentes oscilatórias da potência instantânea e da energia reativa instantânea da CPT. O CEP é controlado em modo corrente, através da estratégia de modulação PWM com duas malhas de controle. A estratégia de compensação e o sistema de controle serão avaliados e testados via simulação para diferentes configurações de cargas, incluindo uma carga não-linear desbalanceada operando em condições onde as distorções e desequilíbrios de tensão sejam consideráveis. Por fim, resultados experimentais obtidos com um protótipo em escala laboratorial são utilizados para validar a estratégia de compensação proposta / Abstract: This master’s thesis proposes the development and implementation of a compensation strategy for the three-phase multifunctional grid-tied inverter. The reference signal generation method for grid-tied is based on the Conservative Power Theory (CPT). In this work, the multifunctional inverter plays the role of the Utility Interface (UI) which perform several functions: in grid-connected operation, it injects active power into the grid and compensates the instantaneous power oscillation and the instantaneous reactive energy oscillation. The goal is to execute theoretical studies and computational simulations to validate the proposed strategy. For this purpose, firstly are identifies the unwanted currents which allow the compensation of the oscillatory terms of instantaneous power and reactive energy. The inverter is controlled in current mode through PWM modulation strategy with two control loops. In addition, the proposed compensation strategy and control system is evaluated and tested for different load configurations, such as linear and nonlinear loads (balanced and unbalanced) operating under different voltage conditions (distorted and unbalanced). Finally, experimental results are presented to validate the effectiveness and performance of the proposed compensation strategy. / Mestre
|
377 |
Five-level inverter employing WRPWM switching schemeChaing, Chia-Tsung 10 July 2008 (has links)
Multilevel Random Pulse Width Modulation (RPWM) schemes have drawn increasing attention in the past few years. Multilevel topologies provide high voltage and high power capabilities and random PWM schemes offer reduction in discrete harmonics spectral. This dissertation provides a generalized theory and analysis methods of the standard five-level Weighted RPWM (WRPWM). Equations have been derived to analyze the spectral performance and average switching frequency of the WRPWM output waveform using statistical approach. A modified WRPWM scheme has been proposed. The modified WRPWM scheme is then analyzed with the equations derived from the same approach. The analyzed theoretical spectrum of the standard five-level WRPWM is then compared with the three-level WRPWM scheme and the conventional carrier based PWM scheme. A scaled laboratory prototype diode clamping five-level inverter has been built for verification of the standard and the proposed modified WRPWM schemes. It can be seen that the experimental measurements and the theoretical analyzed results are all in good agreement. Results show the two five-level WRPWM schemes offers significant improvements on the spectrum content than the conventional carrier based PWM scheme. It was found that the five-level WRPWM schemes have successfully suppress the magnitude of third harmonic below 5% of the magnitude of fundamental component and even less for the higher order harmonic components. Research contributions made by the dissertation are: - The proposed modified multilevel WRPWM scheme which utilizing the switching decision redundancy of multilevel inverter to manipulate the harmonic content of the output signal. - The derived mathematical equations of the standard and modified five-level WRPWM scheme for analytical purposes. / Dissertation (MEng (Electrical Engineering))--University of Pretoria, 2005. / Electrical, Electronic and Computer Engineering / unrestricted
|
378 |
Generation Control in Small IsolatedPower SystemsHaji Miragha, Amirhossein January 2005 (has links)
This thesis is concerned with the generation control in small isolated power systems consisting of inverter interfaced generation systems. First the components of an individual distributed generation system (DGS) as well as the corresponding control schemes for active and reactive power flow are discussed and implemented. Then the contribution of multiple DGS to meet the requirement of the loads in both gridconnected and island operations are discussed. Having evaluated the performance of each developed model such as voltage source inverter, PQ and PV controlled as well as reference DGS, the impact of voltage degradation on power load control in isolated systems is analyzed. Finally a new method for generation control in a small power system based on power sharing between multiple DGS with voltage degradation consideration as the last alternative for sustaining the system is proposed and implemented.-11D
|
379 |
Techno-economic study for a 50 MW PV plant in NigeriaKelly, Jacob January 2021 (has links)
As part of Nigeria’s drive to increase electricity production capacity and shift to renewable sources, a new 50 MW photovoltaic (PV) plant is proposed for a town in north-west Nigeria. Rather than using conventional monofacial modules and fixed mounting, it is of interest to consider a selection of new technologies which are attracting growing attention in the global utility PV market. These can increase energy output, and could be used to advantage in this 50 MW plant. However, the technologies, namely bifacial modules and solar tracking, are more expensive than their conventional counterparts, while their relative performance depends on the latitude and climate of the plant location. Thus their economic benefit cannot be taken for granted. The aim of this study is to propose multiple designs for the 50 MW plant using different combinations of module and mounting technologies, finding their economic order of merit by estimating their respective levelised costs of electricity (LCOEs).Using the simulation software PVsyst, the electricity production of different plant layouts and component configurations was estimated. Key parameters such as tilt angle and pitch distance were varied in order to optimise each configuration of technologies. Having sourced economic data from the industry and literature, lifetime plant costs were calculated, which in combination with lifetime electricity production, were used to estimate the LCOE.As expected, results indicated that the optimum configuration was bifacial modules mounted on horizontal single-axis tracking (SAT), followed by monofacial modules on horizontal SAT. Fixed installations had greater LCOEs by a reasonable margin, while the LCOE difference between monofacial and bifacial modules on fixed mounting was within the error of the calculation, meaning this choice relies on more accurate input data. A sensitivity analysis allowed uncertainty in the results to be gauged, and highlighted the factors which most influence LCOE, so that efforts to increase profitability can be focussed in the right places. Finally, suggestions are offered to help optimise bifacial and tracking installations by comparison with conventional plants.The conclusions drawn herein will be specifically relevant to the Swedish developer and EPC contractor Svenska Solenergigruppen which, in due course, will submit a plant design proposal to the project developer of the 50 MW plant. However, it is hoped that this work will act as a guide for any EPC contractor or developer working on a utility PV plant in sub-Saharan Africa, allowing efficient design of an optimal system.
|
380 |
A Heterogeneous Multirate Simulation Approach for Wide-bandgap-based Electric Drive SystemsOlatunji T Fulani (9581096) 27 July 2021 (has links)
<p>Recent developments in semiconductor device technology have seen the advent of wide-bandgap (WBG) based devices that enable operation at high switching frequencies. These devices, such as silicon carbide (SiC) metal-oxide-semiconductor field-effect transistors (MOSFETs), are becoming a favored choice in inverters for electric drive systems because of their lower switching losses and higher allowable operating temperature. However, the fast switching of such devices implies increased voltage edge rates (high <i>dv/dt</i>) that give rise to various undesirable effects including large common-mode currents, electromagnetic interference, transient overvoltages, insulation failure due to the overvoltages, and bearing failures due to</p>
<p>microarcs. With increased use of these devices in transportation and industrial applications, it is imperative that accurate models and efficient simulation tools, which can predict these high-frequency effects and accompanying system losses, be established. This research initially focuses on establishing an accurate wideband model of a surface-mount permanent-magnet</p>
<p>ac machine supplied by a WBG-based inverter. A new multirate simulation framework for predicting the transient behavior and estimating the power losses is then set forth. In this approach,</p>
<p>the wideband model is separated into high- and low-frequency models implemented using two different computer programs that are best suited for the respective time scales. Repetitive execution of the high-frequency model yields look-up tables for the switching losses in the semiconductors, electric machine, and interconnecting cable. These look-up tables are then incorporated into the low-frequency model that establishes the conduction</p>
<p>losses. This method is applied to a WBG-based electric drive comprised of a SiC inverter and permanent-magnet ac machine. Comparisons of measured and simulated transients are provided.</p>
|
Page generated in 0.2812 seconds