• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 6
  • Tagged with
  • 17
  • 17
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Design and development of sensor for air leak detection /

Chan, Ka-fai. January 1998 (has links)
Thesis (M. Phil.)--University of Hong Kong, 1999. / Includes bibliographical references (leaves 124-127).
2

Design and development of sensor for air leak detection

Chan, Ka-fai. January 1998 (has links)
published_or_final_version / Mechanical Engineering / Master / Master of Philosophy
3

Advanced modelling for on-line monitoring of structural integrity /

Isterling, William Martin. Unknown Date (has links)
Thesis (M.Eng.)--University of South Australia, 1998.
4

The analysis of pipeline leak tests using DEGADIS model

Chamorro, Alexander. January 1999 (has links)
Thesis (M.S.)--West Virginia University, 1999. / Title from document title page. Document formatted into pages; contains ix, 123 p. : ill. (some col.), maps. Includes abstract. Includes bibliographical references (p. 64-65).
5

The remote detection of uranium leaks using fluorescence characteristics

Wakefield, Clare Helen January 1999 (has links)
No description available.
6

Analysis of required supporting systems for the Supercritical CO2 power conversion system

Freas, Rosemarv M. 09 1900 (has links)
Recently, attention has been drawn to the viability of using S-CO(2) as a working fluid in modern reactor designs. Near the critical point, CO2 has a rapid rise in density allowing a significant reduction in the compressor work of a closed Brayton Cycle. Therefore, 45% efficiency can be achieved at much more moderate temperatures than is optimal for the helium Brayton cycles. An additional benefit of the S-CO2 system is its universal applicability as an indirect secondary Power Conversion System (PCS) coupled to most GEN-IV concept reactors, as well as fusion reactors. The United States DOE's GNEP is now focusing on the liquid Na cooled primary as an alternative to conventional Rankine steam cycles. This primary would also benefit from being coupled to an S-CO2 PCS. Despite current progress on designing the S-CO2 PCS, little work has focused on the principal supporting systems required. Many of the required auxiliary systems are similar to those used in other nuclear or fossil-fired units; others have specialized requirements when CO2 is used as the working fluid, and are therefore given attention in this thesis. Auxiliary systems analyzed within this thesis are restricted to those specific to using CO2 as the working fluid. Particular systems discussed include Coolant Make-up and Storage, Coolant Purification, and Coolant Leak Detection. / Contract number: N62271-97-G-0026. / US Navy (USN) author
7

Detection of air leaks using pattern recognition techniques and neurofuzzy networks

林智勤, Lam, Chi-kan. January 2000 (has links)
published_or_final_version / Mechanical Engineering / Master / Master of Philosophy
8

Detection of air leaks using pattern recognition techniques and neurofuzzy networks /

Lam, Chi-kan. January 2000 (has links)
Thesis (M. Phil.)--University of Hong Kong, 2000. / Includes bibliographical references (leaves 187-190).
9

Detecção on-line de vazamentos em vasos de pressão utilizando sistemas sonicos / On-line leak detection in pressure vessels using sonic systems

Pavan, Andre Mauricio 16 February 2005 (has links)
Orientadores: Sandra Lucia Cruz, João Alexandre Ferreira da Rocha Pereira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-07T19:03:10Z (GMT). No. of bitstreams: 1 Pavan_AndreMauricio_M.pdf: 4399374 bytes, checksum: d76e0e55472d41a43569b1e700a1a749 (MD5) Previous issue date: 2005 / Resumo: Vasos de pressão são equipamentos muito importantes numa indústria, sendo responsáveis por armazenar gases, líquidos e outros fluidos a altas pressões. Um pequeno vazamento nesses vasos pode ser muito perigoso, gerando poluição, explosão e perda financeira para a indústria. Por isso, é imprescindível uma rápida e eficaz detecção da ocorrência de qualquer vazamento. Este trabalho descreve o desenvolvimento e teste de uma técnica de detecção de vazamentos de gás em vasos de pressão, baseada na análise da pressão no interior do vaso e doruído sonoro gerado pelo vazamento. Na montagem experimental utilizou-se um vaso de pressão com capacidade 34,5 litros, operando com ar. A pressão no interior do vaso variou de 1 a 7 kgf/cm2. Vazamentos de diversas magnitudes foram simulados através de um orifício, instalado lateralmente no vaso, cujo diâmetro variou de 0,1 a 4,0 mm. Vazamentos foram detectados quando o vaso de pressão operava em batelada e também quando havia alimentação contínua de ar para o vaso. Para a detecção de vazamentos foi utilizado um microfone e um programa, em linguagem C, que faz a aquisição on-line, através de uma placa ADA, dos sinais provenientes de um transdutor de pressão conectado ao vaso e do microfone instalado no interior do vaso. O circuito elétrico que compatibiliza o sinal proveniente do microfone com aquele compreendido pela placa ADA foi desenvolvido no laboratório e apresenta duas etapas. Na primeira o sinal alternado é amplificado e na segunda o sinal passa por filtros passa banda de 1kHz, 5kHz e 9kHz gerando três sinais contínuos em diferentes faixas de freqüência. Os resultados obtidos mostraram que é possível detectar vazamentos através da detecção e análise dos ruídos sonoros gerados por vazamentos em vasos de pressão, mesmo quando a variação na pressão interna do vaso não é significativa. A resposta em freqüência do sinal do vazamento variou com a magnitude do vazamento e com as diferentes condições de pressão no interior do vaso. O sistema desenvolvido mostrou que pode ser uma ferramenta confiável para a supervisão de vasos de pressão / Abstract: Pressure vessels are very important equipment in the industry, being responsible for storing gases, liquids and other fluids at high pressures. A small leakage on them can be very dangerous, generating pollution, explosion and also financials losses to the industry. For those reasons, it is essential to have a fast and efficient leakage detection system. This work describes a leak detection technique of gas based on the analysis of the pressure in the vessel and the noise generated by the leak. An experimental apparatus was set up using a 34.5 liters pressure vessel, fitted with a system to simulate sudden leakage through small orifices. Compressed air was used in the leakage experiments and the pressure in the vessel varied between 1 and 7 kgf/cm2. Leaks of various magnitudes were simulated through orifices with sizes varying between 0.1 and 4 mm in diameter. Leaks were detected when the vessel operated with a batch of air and also when the vessel was continuously fed with air. The leak detection system used a microphone and a software, written in C language, for data acquisition through an ADA converter of the signals generated by a pressure transducer installed in the vessel and by the microphone which was placed inside the vessel. An electric circuit was developed to process the noise captured by microphone and had two different stages:- on the first, the signal was only amplified and, on the second stage, the signal was filtered through three band pass filters, centered in 1kHz, 5kHz and 9kHz each one, generating three continuous signals in different frequencies. The experimental results show that it is possible to detect leaks based on the detection and analysis of sound noises generated by leak occurrence in pressure vessels even when yht pressure in the vessel does not change significantly. The analysis of the signal amplitude for different frequencies shows that the leakage noise signal changes with the leakage size and pressure in the vessel. The developed system shows to be a very reliable tool for safety supervision of pressure vessels / Mestrado / Sistema de Processos Quimicos e Informatica / Mestre em Engenharia Química
10

Detecção de vazamentos em tubulações atraves de metodo acustico e da analise de transientes de pressão / Leak detection in pipelines through acoustic method and pressure transient analysis

Sousa, Elisangela Orlandi de 27 February 2007 (has links)
Orientador: Sandra Lucia da Cruz / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-08T04:57:11Z (GMT). No. of bitstreams: 1 Sousa_ElisangelaOrlandide_M.pdf: 2598884 bytes, checksum: 7421959dcef02a5096290563b5f4500e (MD5) Previous issue date: 2007 / Resumo: Redes de tubulação são sistemas complexos de dutos utilizados no transporte de fluidos a longas distâncias. Um pequeno vazamento em uma tubulação pode provocar grandes perdas de produtos e sérios danos ao meio ambiente até serem detectados. Com o propósito de prevenir vazamentos em tubulações, várias técnicas são relatadas na literatura. Este trabalho descreve o desenvolvimento e teste de uma técnica de detecção de vazamento de gás em tubulação baseada no método acústico e na análise de transientes de pressão gerados a partir do vazamento. Transientes de pressão e o ruído sonoro gerado pelo vazamento foram detectados e analisados em uma tubulação operando sem e com escoamento contínuo de gás (ar) em várias condições de operação. O trabalho experimental utilizou um vazo de pressão de 34,5 litros e uma tubulação com 60 m de comprimento e ½¿ de diâmetro. A pressão de operação variou de 2 a 7 kgf/cm2. Vazamentos de várias magnitudes foram simulados através de um orifício localizado na tubulação cujo diâmetro variou entre 0,4 mm a 5 mm. O microfone e o transdutor de pressão foram instalados no vaso de pressão ou na tubulação para detectar a ocorrência de vazamento, ambos conectados a um computador PC através de um conversor ADA. O sinal gerado pelo microfone foi amplificado e passou por um banco de filtros passa faixa sendo transformado em três sinais com amplitudes independentes, cada uma com uma faixa de freqüência específica de 1kHz, 5kHz e 9kHz. O programa de aquisição de dados foi escrito em linguagem C para ler e processar os dados. Os resultados experimentais mostraram que é possível detectar vazamentos em tubulações através do método acústico. A análise dos sinais de amplitude para freqüências diferentes mostrou que o ruído sonoro gerado pelo vazamento depende da magnitude do vazamento e da pressão na tubulação. Em todos os experimentos a ocorrência de vazamento foi prontamente detectada pelo microfone enquanto as mudanças nos perfis de transientes de pressão não eram sempre significativas para detectar o vazamento / Abstract: Pipeline networks are complex systems of ducts used in the fluid transportation through long distances. Even small leaks in a pipeline can lead to great losses of product and serious damages to the environment before it could be detected. With the purpose of preventing leakage in pipelines, various techniques have been reported in the literature. This work describes the development and test of a gas leak detection technique in pipelines based on an acoustic method and on the analysis of pressure transients generated by the leak. Pressure transients and the noise generated by leakage have been detected and analysed in a pipeline operating with and without continuous flow of gas (air) under various operation conditions. The experimental setup made use of a 34,5 liters pressure vessel and a 60 m long, ½¿ in diameter pipeline. The operational pressure varied from 2 to 7 kgf/cm². Leakages of various magnitudes were simulated through an orifice located in pipeline whose diameter varied from 0,4 mm to 5,0 mm. A microphone and a pressure transducer were installed either in the pressure vessel or in the pipeline to detect leak occurrence, both being connected to a PC computer through an ADA converter. The signal generated by the microphone was amplified and also passed through a bank of band pass filters being transformed into three signals with independent amplitude, each one with a band of specific frequency of 1 kHz, 5 kHz and 9 kHz. The data acquisition software was written in C language to read and process all data. The experimental results showed that it is possible to detect leaks in pipelines based on acoustic method. The analysis of the signal amplitude for different frequencies showed that the noise signal generated by leakage depend on both leak magnitude and pressure in the pipeline. In all experiments leak occurrence was readily detected by the microphone while the changes in pressure transient profiles were not always significant to detect the leak / Mestrado / Sistemas de Processos Quimicos e Informatica / Mestre em Engenharia Química