• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 7
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 23
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Évaluation de la reconstruction des ligaments croisés post luxation aiguë du genou avec l’utilisation des ligaments synthétiques

De Oliveira Junior, Eros 06 1900 (has links)
La luxation du genou, bien que très rare, demeure une blessure dévastatrice car elle entraîne de multiples complications en raison de la nature complexe du traumatisme associé à cette lésion. La luxation peut résulter d'un traumatisme à haute ou basse énergie. Les blessures sévères aux ligaments et aux structures associées donnent à la luxation du genou un potentiel élevé d'atteinte fonctionnelle. Le traitement conservateur, qui était considéré comme acceptable auparavant, est maintenant réservé à un très faible pourcentage de patients. La reconstruction chirurgicale est maintenant préconisée dans la plupart des cas, mais de nombreuses options existent et le traitement chirurgical optimal à préconiser reste controversé. Certains chirurgiens recommandent la reconstruction complète de tous les ligaments endommagés le plus tôt possible, tandis que d'autres, craignant l’établissement d’arthrofibrose, limitent l'intervention chirurgicale immédiate à la reconstruction du ligament croisé postérieur et de l'angle postéro-externe. En raison des multiples structures endommagées lors d’une luxation du genou, les chirurgiens utilisent couramment la combinaison des autogreffes et des allogreffes pour compléter la reconstruction ligamentaire. Les complications associées au prélèvement de la greffe, l'allongement de la greffe, l’affaiblissement précoce du greffon ainsi que les risques de transmission de maladies ont poussé les chirurgiens à rechercher différentes options d’intervention. L'utilisation de matériaux synthétiques pour le remplacement du ligament lésé a été proposée dans les années ´80. Après une première vague d'enthousiasme, les résultats décevants à long terme et les taux élevés d'échec ont diminué sa popularité. Depuis lors, une nouvelle génération de ligaments artificiels a vu le jour et parmi eux, le Ligament Advanced Reinforced System (LARS) a montré des résultats prometteurs. Il a été utilisé récemment dans les reconstructions isolées du ligament croisé antérieur et du ligament croisé postérieur pour lesquelles il a montré de bons résultats à court et moyen termes. Le but de cette étude rétrospective était d'évaluer la fonction et la stabilité du genou après la luxation aiguë suivant la reconstruction des ligaments croisés avec le ligament artificiel de type LARS. Cette étude a évalué 71 patients présentant une luxation du genou et qui ont subi une chirurgie de reconstruction du ligament croisé antérieur et du ligament croisé postérieur à l'aide du ligament LARS. Suite à la chirurgie le même protocole intensif de réadaptation a été suivi pour tous les patients, où la mise en charge progressive était permise après une période d’environ 6 semaines pendant laquelle la force musculaire et la stabilité dynamique se rétablissaient. Les outils d’évaluation utilisés étaient le score Lysholm, le formulaire de «l’International Knee Documentation Committee», le «Short Form-36», les tests cliniques de stabilité du genou, l'amplitude de mouvement articulaire à l’aide d’un goniomètre et la radiographie en stress Telos à 30° et 90° de flexion du genou. Le même protocole d’évaluation a été appliqué au genou controlatéral pour des fins de comparaison. Les résultats subjectifs et objectifs de cette étude sont satisfaisants et suggèrent que la réparation et la reconstruction combinées avec ligaments LARS est une alternative valable pour le traitement des luxations aiguës du genou. Ces résultats démontrent que ces interventions produisent des effets durables en termes d’amélioration de la fonction et révèlent la durabilité à long terme des ligaments artificiels LARS. Les patients sont à la fois plus autonomes et plus satisfaits avec le temps, même si la luxation du genou est considérée comme une catastrophe au moment où elle se produit. Des études prospectives randomisées sont maintenant nécessaires afin de comparer la sélection de la greffe et le délai de reconstruction chirurgicale. / Knee dislocation, although very rare, remains a devastating injury with many complications because of the complex nature of this trauma. This uncommon injury can result from either a high or low energy trauma. The severe damage to the knee’s ligaments and associated structures render this injury at high potential for functional impairment. Non operative treatment which was once deemed acceptable, is now reserved for very low demand patients. Surgical reconstruction is now the standard of care for most patients, however many options exist but the optimal surgical treatment remains controversial. Some surgeons advocate early complete reconstruction of all damaged ligaments, whereas others who fear arthrofibrosis, limit the immediate surgery to reconstruction of the posterior cruciate ligament and the posterolateral corner. Because of the multiple structures damaged by knee dislocations, surgeons have been successfully using combinations of autografts and allografts for complete knee ligament reconstruction. Complications associated with graft harvesting, graft elongation and early weakness as well as risks for disease transmission has pushed surgeons to look for different options. The use of synthetic material for ligament replacement was proposed in the 1980’s. After an initial wave of enthusiasm, poor long term results and high rates of failure diminished its popularity. Since then, a new generation of artificial ligaments has emerged, the Ligament Advanced Reinforced System (LARS) has shown promising results. It recently has been used in isolated anterior cruciate ligament and posterior cruciate ligament reconstruction and has shown good short to medium term results. The purpose of this retrospective study was to evaluate the knee function and stability after acute knee dislocation reconstructed with LARS artificial ligaments. This study assessed the results of 71 patients with knee dislocations who underwent acute combined repair and reconstruction of anterior cruciate ligament and posterior cruciate ligament using LARS artificial ligaments. After the surgery all patients followed the same intensive rehabilitation protocol. Progressive weight bearing was permitted over 6 weeks as muscle strength and dynamic stability were regained. The outcome measures used were the Lysholm score, the International Knee Documentation Committee form, the Short Form-36, clinical knee stability testing, a goniometer to mesure the range of motion and Telos stress radiography at 30° and 90° of knee flexion. The non-operated knee of the patient was used as a baseline for the operated knee. The subjective and objective findings from this study are satisfactory and suggest that acute combined repair and reconstruction with LARS ligaments is a valid alternative for treating acute knee dislocations. These findings demonstrate sustained results in terms of function and revealed durability of LARS artificial ligaments at long-term. Patients seem to get more autonomous and satisfied with time even though acute knee dislocation is seen as a catastrophe when it happens. Randomised, prospective trials are now needed to compare graft selection and timing of the surgical reconstruction.
22

Évaluation de la reconstruction des ligaments croisés post luxation aiguë du genou avec l’utilisation des ligaments synthétiques

De Oliveira Junior, Eros 06 1900 (has links)
No description available.
23

Subluxation de la tête radiale suite au malalignement du cubitus proximal : une étude biomécanique

Sandman, Emilie 03 1900 (has links)
Le cubitus proximal détient une courbe sagittale unique pour chaque individu, nommée « Proximal Ulna Dorsal Angulation (PUDA) ». Une reconstruction non-anatomique du cubitus proximal, suite à une fracture complexe peut engendrer une malunion, de l’arthrose et de l’instabilité. L’objectif de cette étude était d’évaluer la magnitude de malalignement au niveau de l’angulation proximale dorsale du cubitus qui causerait un malalignement radio-capitellaire, avec et sans un ligament annulaire intact. Afin d’atteindre cet objectif, une étude biomécanique fut conduite sur six spécimens frais congelés avec un simulateur de mouvement du coude. Des fractures simulées au niveau du PUDA, furent stabilisées avec une fixation interne dans cinq configurations différentes. Des images fluoroscopiques furent prises dans différentes positions du coude et de l’avant-bras, avec le ligament annulaire intact, puis relâché. Le déplacement de la tête radiale fut quantifié avec le ratio radio-capitellaire. Une interaction significative fut découverte entre les positions du coude, les angles de malalignement et l’intégrité du ligament annulaire. La subluxation de la tête radiale fut accentuée lors de la déchirure du ligament annulaire. Une augmentation de la subluxation antérieure de la tête radiale fut observée lorsque le malalignement était fixé en extension et lors de mouvements de flexion progressive du coude. D’autre part, un malalignement en flexion et une extension graduelle du coude occasionnait une subluxation postérieure. En conclusion, les résultats ont démontré l’importance d’une reconstruction anatomique du cubitus proximal, car un malalignement de 5 degrés engendre une subluxation de la tête radiale, surtout lors d’une déchirure du ligament annulaire. / It has been shown that the proximal ulna has a sagittal bow, named the Proximal Ulna Dorsal Angulation (PUDA), unique for each individual. Non-anatomic reconstruction of the proximal ulna following a complex injury may lead to malunion, arthrosis and instability, hence the importance of understanding its initial anatomy. The purpose of this study was to evaluate the magnitude of angular malalignement at the proximal ulna dorsal angulation that would lead to radiocapitellar malalignement, with and without an intact annular ligament. In order to achieve our goal, a biomechanical study was conducted on six fresh frozen specimens, with an elbow movement simulator. Simulated fractures at the PUDA were stabilized with internal fixation at five different angles. Then, fluoroscopic images were taken in different elbow and forearm positions, first with the annular ligament intact and then released. Radial head displacement was quantified with the Radio-Capitellar-Ratio (RCR). Overall, a significant interaction was found between elbow positions, angles of malalignement and annular ligament integrity. Radial head subluxation was emphasized when the annular ligament was ruptured. Moreover, anterior subluxation of the radial head increased as malalignement was fixed into extension and with progressive elbow flexion. Furthermore, posterior subluxation increased with malalignement into flexion and with elbow extension. In conclusion, our results demonstrate the importance of obtaining an anatomic reconstruction, specific for each individual’s unique proximal ulna dorsal angulation, following a proximal ulna fracture. Indeed, malalignment of 5 degrees can lead to abnormal tracking of the radial head, especially when associated with annular ligament tear.

Page generated in 0.0922 seconds