• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 825
  • 272
  • 15
  • 11
  • 11
  • 11
  • 11
  • 10
  • 9
  • 9
  • 8
  • 8
  • 3
  • 3
  • 2
  • Tagged with
  • 1140
  • 393
  • 322
  • 265
  • 202
  • 193
  • 167
  • 147
  • 144
  • 141
  • 121
  • 115
  • 114
  • 100
  • 96
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
901

“A NOSSA SAÚDE ESTÁ AQUI”:Os discursos médicos-higienistas e a medicalização dos corpos na revista Era Nova (Parahyba, 1921- 1925).

ALMEIDA, Alanny Paulo Ricardo de. 26 April 2018 (has links)
Submitted by Jesiel Ferreira Gomes (jesielgomes@ufcg.edu.br) on 2018-04-26T20:54:41Z No. of bitstreams: 1 ALANNY PAULO RICARDO DE ALMEIDA – DISSERTAÇÃO (PPGH) 2015.pdf: 4186124 bytes, checksum: 52ee226989f5e4e978f922a873359947 (MD5) / Made available in DSpace on 2018-04-26T20:54:41Z (GMT). No. of bitstreams: 1 ALANNY PAULO RICARDO DE ALMEIDA – DISSERTAÇÃO (PPGH) 2015.pdf: 4186124 bytes, checksum: 52ee226989f5e4e978f922a873359947 (MD5) Previous issue date: 2015-09-25 / Capes / Esta dissertação objetiva problematizar a difusão dos discursos médico-higienistas, a medicalização e as representações dos corpos na Parahyba. O cenário escolhido para tal análise foi a revista ilustrada Era Nova que circulou na Parahyba entre os anos de 1921 e 1925, recorte temporal desta pesquisa. Tal periódico estava inserido em um circuito nacional de produção impressa que anunciava e ilustrava os arquétipos da modernidade em suas páginas. A modernidade pretendida neste período tinha no campo científico e principalmente em áreas como a medicina, a eugenia, o higienismo, e o sanitarimos aliados e promotores de uma cruzada contra o atraso, a “degenerância das raças”, a sujidade e as doenças, que segundo tal pensamento assolavam o país. Destarte, nossa narrativa é norteada pela História Cultural e pela historiografia da Saúde e da Doença, assim evidenciamos os estudos das representações do corpo e das corporeidades, em diálogo com o campo das sensibilidades, na medida em que buscamos questionar as diversas formas de perceber e descrever o corpo doente e o corpo saudável bem como as estratégias de educação dos sentidos e incentivos a novas práticas cotidianas balizadas pelo discurso científico, que intentava civilizar, normatizar e medicalizar o corpo, tornando-o saudável, em dia com os preceitos médico-sanitários. / This dissertation aims to problematize the dissemination of medical hygienists speeches, medicalization and the representations of bodies in Parahyba. The setting chosen for this analysis was the illustrated magazine was circulated in New Parahyba between the years 1921 and 1925 time frame of this research. Such journal was entered in a national circuit of printed production announced and illustrated the archetypes of modernity in its pages. The intended modernity in this period had in the scientific field and especially in areas such as medicine, eugenics, hygienist, and the allies sanitarimos and promoters of a crusade against the delay, "degenerância of the races", dirt and disease, which second the thought plagued the country. Thus, our narrative is guided by cultural history and the history of health and disease, as evidenced studies of representations of the body and corporeality, in dialogue with the field of sensitivities, as we seek to question the different ways of perceiving and describe the patient's body and the body healthy and the education strategies of the senses and incentives to new daily practices buoyed by scientific discourse, that I thought to civilize, standardize and medicalize the body, making it healthy, current with the medical and health requirements .
902

O sistema de referência e contra-referência no atendimento ao adolescente infrator : percepção dos profissionais de saúde da Fundação CASA /

Torralbo, Fernanda Augusta Penacci. - January 2008 (has links)
Orientador: Carmem Maria Casquel Monti Juliani / Banca: Silvia Cristina Mangini Bocchi / Banca: Moneda Oliveira Ribeiro / Resumo: Enquanto Supervisora Técnica da área da saúde da Fundação CASA, o interesse pela temática surgiu em decorrência da preocupação com o direito à saúde, garantido por lei. O objetivo da pesquisa foi compreender a percepção da equipe de saúde da Fundação CASA (médicos, enfermeiros e auxiliares de enfermagem) sobre o funcionamento do sistema de referência e contra referência da rede pública de saúde, quando se faz necessário o encaminhamento do adolescente. A metodologia, de caráter qualitativo, utilizou a fenomenologia. As entrevistas áudio-gravadas foram realizadas entre maio e agosto de 2007, após assinatura do termo de consentimento livre e esclarecido. Após as etapas de transcrição, redução e compreensão fenomenológica foram evidenciadas os temas e as categorias e. As categorias são: o acesso ao atendimento à saúde pelo SUS, a condição de ser adolescente em conflito com a lei, o direito à saúde e a organização dos serviços de saúde. Os achados mostram a importância do desenvolvimento de pactuações com os municípios, exigindo maiores responsabilidades dos serviços na formulação de políticas de saúde vinculadas ao adolescente, assim como deve ocorrer para qualquer cidadão. Isto implica, na necessidade de propostas de gestão e melhoria da organização conforme diretrizes e princípios do Sistema Único de Saúde. / Abstract: As a health care Technical Supervisor for CASA Foundation, the interest in this topic arose from the concern about the right to health care, which is warranted by law. This study aimed at understanding the perception of the health care team working for CASA Foundation (physicians, nurses and nursing auxiliaries) as regards the functioning of the referral and contra referral system of the public health care network when adolescents' referral is required. The qualitative methodology was used based on phenomenology. The audio-taped interviews were conducted from May to August, 2007 after a free and informed consent document was signed by the participants. Following the transcription, reduction and phenomenological comprehension phases, the topics and categories were shown. The categories are: access to health care through the Unified Health Care System (SUS), the condition of being an adolescent in conflict with the law, the right to health care and the organization of health care services. The findings show the importance of developing agreements among municipalities, requiring greater liability from services in the formulation of health care policies for adolescents, similarly to what should occur for any other citizen. This implies the need for management proposals and organization improvement according to guidelines and principles of the Unified Health Care System. / Mestre
903

Aparelho de baropodometria para uso na reabilitação de alterações de marcha

Scremim, Reginato Domingos 27 April 2012 (has links)
As alterações neuro-motoras podem diminuir os movimentos, as atividades de vida diária e o convívio social. Dentro dessas alterações encontram-se as dispraxias ou apraxias dos movimentos que podem desequilibrar o movimento voluntário, principalmente dos músculos do tornozelo e desenvolver uma rigidez do movimento conhecida como "pé equino" diminuindo o apoio do calcanhar e consequentemente o controle do equilíbrio do corpo dificultando a deambulação. Como fonte de ajuda às pessoas acometidas por esse problema, desenvolveu-se um equipamento denominado Baropodômetro que utiliza o conceito de biofeedback, fornecendo informações audiovisuais, com o propósito de estimular e ou corrigir a falta de apoio do calcanhar no solo auxiliando na percepção do equilíbrio e correção da marcha. O equipamento faz a leitura da pressão aplicada pela parte da frontal e traseira dos pés sobre o solo por meio de sensores colocados em palmilhas e acomodados em calçados (e.g., sandálias). Essa ação é traduzida visualmente através de números mostrados em displays e por colunas de leds que acendem em sequência na medida em que a pressão sobre os sensores aumentam, bem como por um sinal de áudio com frequência variável e volume ajustável produzido por um alto-falante interno. O equipamento pode armazenar os dados coletados em um cartão de memória que pode ser lido em um microcomputador, permitindo montagens de tabelas e gráficos para análise posterior viabilizando o planejamento da ação de reabilitação. Com o auxilio de um método de reabilitação, o aparelho foi validado clinicamente com a participação de um grupo de dez pacientes voluntários que obtiveram um excelente resultado (i.e., todos os pacientes após 10 sessões conseguiram apoiar o pé comprometido) mostrando que é possível a reabilitação com a utilização do aparelho desenvolvido. / The neuro-motor changes can reduce the movements, activities of daily living and social life. Within these changes are the dyspraxia or apraxia of movements that can unbalance the voluntary movement, especially of the ankle muscles and develop a stiffness of movement known as "equinus foot". The equinus foot decreases the heel support and consequently the balance control of the body making it difficult to walking properly. As a source of help to people affected by this problem, we developed a device called Baropodometer that uses the concept of biofeedback, providing audiovisual information in order to stimulate and or correct the absence of heel strike on the ground assisting in the realization and correction of balance and gait. The device reads the pressure applied by the front and rear part of the foot on the ground by means of sensors placed in insoles and accommodated in shoes (e.g., sandals). This action is translated visually through numbers shown in displays and columns of LEDs that are illuminated according to the increase of the pressure on the sensors, as well as an audio signal with variable frequency and adjustable volume produced by an internal buzzer. The device can store the collected data in a memory card that can be read on a microcomputer, allowing creation of tables and graphs for further analysis enabling the planning of rehabilitation action. With the help of a method of rehabilitation, the device was clinically validated with the participation of ten volunteers who achieved an excellent result (i.e, all patients after 10 sessions were able to properly support the equinus foot) showing that the rehabilitation is possible with the use of the developed device.
904

Riscos na reutilização de produtos médicos esterilizados em óxido de etileno

Sundin, Mônica Saladini 15 July 2014 (has links)
O presente estudo analisou 275 resultados de resíduos de óxido de etileno (OE) e subprodutos tais como etilenoglicol (ETG) e etilenocloridrina (ETCH), em produtos médicos esterilizados com óxido de etileno. A metodologia utilizada difere de outros estudos por não ser uma simulação, mas sim casos reais de produtos esterilizados nos quais se mediu a quantidade de resíduos. As quantidades de resíduos obtidas foram comparadas com os limites máximos estabelecidos por normas. Observou-se uma grande adequação dos resultados aos limites estabelecidos por norma. No entanto problemas foram encontrados, principalmente, na grande quantidade de valores aberrantes, problema este que indica possíveis problemas na fase de aeração dos produtos. Para a fundamentação do presente estudo foram feitos estudos complementares, aqui apresentados com os nomes de: Análise de Incertezas em Curvas de Calibração de um Cromatógrafo na Medição de Resíduos de Óxido de Etileno; Resíduos de Óxido de Etileno em Esponja Cirúrgica Gelfoam® e Resíduos de Óxido de Etileno em Soro Fisiológico 0,9%. / The present study analyzed 275 results for residues of ethylene oxide (ETO) and by-products such as ethylene glycol (ETG) and ethylene chloridrine (ETCH), in medical devices sterilized using ethylene oxide. The methodology differs from other studies for not being a simulation, but rather real cases of sterilized devices in which the amount of residue was measured. The quantities of residues obtained were compared with the top levels established by regulations. There was a great adjustment of the results to the limits established by the regulation. However problems were found mainly in the large amount of outliers values, a problem that indicates possible issues during the airing stage of the devices. In order to support this study, related studies have been made and are presented here with the names: Analysis of Uncertainty in Chromatograph Calibration Curves in Ethylene Oxide Residues Measuring; Ethylene Oxide Residuals in Gelfoam® and Ethylene Oxide Residuals in Saline Bottles.
905

Desenvolvimento e aplicação de um protocolo osteopático de tratamento para bebês com refluxo

Gemelli, Mauro 13 November 2014 (has links)
Estudos revelam uma prevalência do refluxo gastroesofágico (RGE) em bebês no Brasil entorno de 11,5% a 18,2%, semelhante aos dados internacionais, trazendo sintomas que podem se perpetuar até a infância e adolescência. Os protocolos de tratamento atuais são em resumo medicamentosos. Poucos estudos referem evidências sobre terapias complementares no tratamento do refluxo. A osteopatia poderia ser utilizada neste contexto para tratar as causas do refluxo, porém, estudos que determinem Protocolos Osteopáticos de Tratamento (POT) são limitados e não são específicos para este diagnóstico. Assim, o objetivo deste estudo foi avaliar a aplicação de um POT desenvolvido para bebês de zero a um ano através de um método quantitativo. Foi realizado um estudo descritivo longitudinal com 59 bebês com idade entre zero e um ano de idade diagnosticados com refluxo e em tratamento medicamentoso. Inicialmente todos foram avaliados com o questionário I-GERQ-R. Trinta e três crianças foram selecionadas para o grupo A, que foi submetido ao POT em paralelo ao tratamento farmacológico, ou durante dois meses ou até atingir um score mínimo no questionário, o que ocorresse primeiro. O grupo B foi acompanhado pelo mesmo período, sendo reavaliado após dois meses. Foram analisados os dados coletados do questionário e os sintomas associados de cólica e tosse. No grupo A, a média inicial do score I-GERQ-R foi de 14,57 ±3,65 e a final 1,39 ±2,09 pontos (p=0,001). No grupo B estes valores foram respectivamente 17,23 ±4,78 e 8,46 ±7,41, caracterizando uma permanência do grupo B no diagnóstico de refluxo (escore>7) apesar da melhora com significância estatística (p=0,043). No grupo A 13 indivíduos chegaram ao escore final zero (“0”), enquanto que no grupo B nenhum indivíduo atingiu este escore. A redução da prevalência no uso de medicação ao final do estudo no grupo A foi de 75,76% enquanto que no grupo B esta redução foi de 11,54%. A melhora no grupo A ocorreu em um tempo médio de 28,76 ± 11,43 dias, independente da idade, onde o número médio de sessões foi 3,91 ±0,80. O sintoma de vômito apresentou melhora significativa no grupo A (p=0,001) mas não no grupo B (p=0,063). O sintoma de azia apresentou uma melhora significativa em ambos os grupos A e B (p=0,001 e p=0,002 respectivamente), bem como o soluço (p=0,001 e p=0,001 respectivamente). O sintoma de choro apresentou melhora significativa para o grupo A (p=0,001), porém não para o grupo B (P=0,123). Da mesma forma, os episódios de engasgos apresentaram redução estatisticamente significativa no grupo A (p=0,001) e não no grupo B (p=0,105). A tosse no grupo A foi reduzida em 94,45% (p=0,001) e a cólica em 75% (p=0,001). No grupo B a tosse permaneceu com a mesma incidência (14 casos) (p=1,000) e o sintoma de cólica aumentou 88,89% (de nove para 17 casos) (p=0,008). Conclui-se, portanto, que o POT proposto se mostrou eficaz na redução dos sintomas do refluxo em bebês e sintomas de tosse e cólica associados, em um tempo aproximado de 29 dias a níveis próximos à zero, tempo inferior ao descrito na literatura. Entende-se que o protocolo tenha atingido os mecanismos de causa do RGE, e, portanto a associação do POT com o tratamento medicação pode ser sugerido na abordagem do RGE em bebês de zero a um ano de idade. / The prevalence of gastroesophageal reflux disease (GERD) in infants in Brazil is about 11.5% to 18,2%, similar to international data, bringing symptoms that can be perpetuated into childhood and adolescence. Current treatment protocols are medicated summary, and few studies have reported evidence for complementary therapies in the treatment of reflux. Osteopathy could be used in this context to treat the causes of reflux, however, studies evaluating Osteopathic Protocols Treatments (OPT) are limited and are not specific for this diagnosis. The objective of this study was to develop and evaluate the application of a OPT developed for infants less than one year through a quantitative method. A longitudinal descriptive study of 59 babies aged under one year of age diagnosed with reflux and in a drug treatment was performed. Initially all were evaluated with I-GERQ-R questionnaire. Thirty- three children were selected for group A, which was submitted to OPT parallel to pharmacological treatment for two months or until it reaches a minimum score on the questionnaire, whichever came first. Group B was accompanied by the same period of two months and after that being re-evaluated. Data collected from the questionnaire and the associated symptoms of colic and cough were analyzed. In group A, the initial average score I-GERQ-R was 14.57 ±3.65 and 1.39 ±2.09 points at the end (p = 0.001). In group B these values were 17.23 ±4.78 and 8.46 ±7.41 points, featuring a stay of group B in the diagnosis of reflux (score>7) despite improvement with statistical significance (p = 0.043). In group A, 13 subjects reached the final score zero ("0"), while in group B no individual reached this score. Reduced use of medication in group A was 75.76% while in group B this reduction was only 11.54%. The improvement in group A occurred at a mean time of 28.76 ±11.43 days, regardless of age, where the average number of sessions was 3.91 ±0.80. The symptom of vomiting improved significantly in group A (p = 0.001) but not in group B (p = 0.063). The symptom of heartburn showed a significant improvement in both groups A and B (p = 0.001 and p = 0.002 respectively), as well as hiccup (p = 0.001 and p = 0.001 respectively). The symptom of crying showed significant improvement in group A (p = 0.001), but not for group B (P = 0.123). Likewise, choking episodes exhibited statistically significant reduction in group A (p = 0.001) and not in group B (p = 0.105). Coughing in the group A was reduced by 94.75% (p=0,001) and 75% in colic (p=0,001). In group B the cough remained with the same incidence (14 cases) (p=1,000) and colic increased significantly from nine to 17 cases (p=0,008). Therefore, it is concluded that the proposed OPT was effective in reducing symptoms of reflux in infants and symptoms of cough and colic associated in an approximate 29 days to levels close to zero, time lower than that described in the literature. It is understood that the protocol has reached the causal mechanisms of GER, and therefore the association of OPT with a medication treatment may be suggested in the approach of GER in infants less than one year old.
906

Estimulador elétrico neuromuscular bifásico com saída em ponte H isolada eletricamente

Gaiotto, Marcelo do Carmo Camargo 30 November 2012 (has links)
A eletrônica empregada no desenvolvimento de estimuladores elétricos funcionais contempla enorme diversificação de técnicas e tecnologias, cujas soluções para o estágio de saída variam desde circuitos transistorizados (bipolares ou MOSFETs), transformadores de pulso até amplificadores operacionais de alta tensão. Desenvolver um estimulador elétrico neuromuscular bifásico com saída em ponte H isolada eletricamente. O sistema de estimulação elétrica neuromuscular bifásico contém saída em ponte H utilizando somente transistores MOSFET canal N, permitindo a geração de pulsos bifásicos e monofásicos com controle de amplitude independente para cada pulso, por meio de uma plataforma eletrônica flexível, que possibilita sua utilização com diversos tipos de elementos de controle, desde microcontroladores e FPGA até dispositivos de instrumentação virtual do tipo LabView. Foram realizados testes de bancada que permitiram avaliar o desempenho do instrumento todo e de seus módulos separadamente. A faixa de alimentação utilizada nos testes foi de 12 a 24V, sendo relacionada diretamente a técnica de geração da alta tensão empregada que permitiu produzir de 280 V a 300 V, utilizados na ponte H, que por sua vez, apresentou o desempenho esperado fornecendo pulsos bifásicos com valores de pico a pico de até 600 V, que pudendo ter sua amplitude dos pulsos controlada individualmente com uma resolução de 73,26 mV (4096 passos), permitindo, assim, a geração de diferentes padrões estimulatórios criados a partir da interface gráfica. O estimulador projetado propiciou o desenvolvimento de uma nova técnica de saída em ponte H utilizando transistores MOSFET canal N na construção de estimuladores elétricos neuromusculares com saída bifásica e com controle de amplitude independente para cada pulso. Tal funcionalidade poderá contribuir para novos estudos e trabalhos em reabilitação empregando estimulação elétrica neuromuscular, considerando que, por meio da interface gráfica criada, formas de ondas estimulatórias específicas podem ser geradas. / The electronics used in the development of functional electrical stimulators include huge diversification of techniques and technologies, whose solutions for the output stage range from transistor circuits (bipolar or MOSFET), to pulse transformers and high-voltage operational amplifiers. To develop a biphasic neuromuscular electrical stimulator with electrically isolated H-bridge output. The electrical neuromuscular stimulation system contains biphasic H-bridge output using only N-channel MOSFET transistors, allowing the generation of mono and biphasic pulses whose pulse amplitudes are independently controlled by a flexible electronics platform, which enables its use with different types of control elements, from microcontroller and FPGA devices to Labview virtual instrument. Bench tests were performed that allowed to assess the performance of the instrument and all its modules separately. The power range used in the tests was 12 to 24V, the technique is directly related to generate the high voltage used which allowed to produce 280 V to 300 V, used in the H bridge, which in turn performed as expected providing pulses biphasic with peak to peak values of 600 V, which pudendal have its amplitude pulses individually controlled with a resolution of 73.26 mV (step 4096), thus allowing the generation of stimulatory different patterns created from the graphical interface. The project developed led the design of a new technique for H-bridge output using transistors N-channel MOSFET in the construction of biphasic neuromuscular electrical stimulator with independent amplitude control for each pulse. Such functionality can contribute to new studies and rehabilitation using neuromuscular electrical stimulation, whereas through the graphical user interface created stimulatory specific waveforms can be generated.
907

Proposta de modelo de gestão de confiança para internet das coisas médicas / A Model Proposal for Trustworthiness Management for Internet of Medical Things

Brittes, Marisangela Pacheco 07 December 2016 (has links)
Nos últimos anos, o paradigma da Internet das Coisas (IoT) foi introduzido, ganhando relevância como uma tecnologia emergente, composta por redes amplamente conectadas e heterogêneas. No contexto médico essas redes suportam diferentes tipos de processos, sendo compostas por diversos tipos de dispositivos denominados objetos, os quais são capazes de interagir uns com os outros, colaborando para atingir um objetivo comum (diagnóstico, tratamento, monitoramento e reabilitação de pacientes). Este cenário caracteriza-se como Internet de Coisas Médicas (IoMT) e um dos maiores desafios a serem superados é o desenvolvimento de mecanismos de gestão de confiança para assegurar trocas de dados com um certo nível de credibilidade. Este trabalho propõe um modelo para gestão de confiança em redes IoMT a partir de conceitos de redes sociais e critérios de relevância biomédica. O modelo proposto baseia-se em um índice de recomendação calculado por um protocolo determinístico de gestão de confiança. Para avaliar sua eficácia, foram criadas simulações com diferentes cenários de redes IoMT. O modelo demonstrou ser útil para detectar objetos com comportamento suspeito na rede, evitando o estabelecimento de relações com estes objetos e minimizando os danos causados à IoMT durante as trocas de dados. / In recent years, the Internet of Things (IoT) paradigm has been introduced, getting attention as an emerging technology, built upon pervasive connectivity of objects in heterogeneous networks. Medical environments are composed by many devices named objects that are able to interact with each other and collaborate in order to achieve a common objective (diagnosis, treatment, monitoring and patient rehabilitation). This scenario is characterized as Internet of Medical Things (IoMT) and one of its greatest challenges is to develop trustworthiness mechanisms to assure data exchanges in a certain level of credibility. This work proposes a model to manage trustworthiness for IoMT networks based on social network concepts and biomedical relevance criteria. The proposed model is based on a trust recommendation index, computed by a deterministic trustworthiness management protocol. To evaluate the model effectiveness, simulations were created with different IoMT scenarios. The model demonstrated to be useful to detect objects with suspicious behavior in the network, avoiding their relationships establishment and minimizing the IoMT damage during the data exchanges.
908

Avaliação de Kerma na superfície de entrada da pele em pacientes pediátricos do Hospital de Clínicas de Curitiba

Porto, Lorena Elaine 09 April 2010 (has links)
CAPES / No presente trabalho foram feitas medidas de dose recebida pelos pacientes pediátricos em exames de radiográficos de tórax em uma amostra de 386 exposições nas projeções AP/PA e Perfil. Os pacientes foram divididos em nas faixas etárias de 0-1 ano, 1-5 anos, 5-10 anos e 10-15 anos. Os exames foram realizados no Hospital de Clínicas da UFPR. Foi medida inicialmente a dose de entrada na pele com dosímetros termoluminescentes TLD-100 em uma amostra de 68 exposições, distribuídos pelas faixas etárias adotadas. A dose foi também determinada utilizando-se cálculos dosimétricos, que faz a determinação de dose para cada paciente a partir do rendimento do aparelho de raios X. O programa utiliza como dados de entrada a massa do paciente, a idade, a distância foco-pele, os dados da técnica radiográfica empregada (kV e mAs) e o valor de uma medida do rendimento feita com câmara de ionização para fins de calibração. Os primeiros dados avaliados mostraram doses maiores para os pacientes mais jovens. Uma mudança na técnica radiográfica dos exames contribuiu para a redução das doses. Foi avaliado todo o procedimento radiográfico e ficou caracterizada a necessidade de uma adequação da técnica radiográfica e uma constante otimização de todo o procedimento. Os dados foram colhidos novamente em 2007 e depois em 2009. Num primeiro momento os níveis de dose se mantiveram. Em 2009 os valores voltaram a subir devido ao aumento da carga (mAs). Os dados obtidos foram então comparados com os limites de dose permissíveis determinados pelos órgãos competentes. / In the present work absorbed doses by pediatric patients in chest radiographs were measured in 386 x-ray examinations in AP/PA and LAT projections. The patients were divided in age groups of 0-1 years, 1-5 years, 5-10 years and 10-15 years. The examinations were made at the pediatric room of Clinical Hospital of the Federal University of Paraná. Initially the entrance skin dose was measured with thermoluminescent dosimeters TLD-100 in 68 expositions, distributed in the age groups. The dose was also determined with the software dosimetric calculations that calculates the dose for each patient, from the X-ray equipment yield. The program uses the following data as input: patient mass, age, skin-focus, radiographic technique (kV, mAs), and the yield measurement made with an ionization chamber for calibration. The first evaluated data showed higher doses for the younger patients. A change in the radiographic technique of the examinations contributed to the reduction of the doses. The whole radiographic procedure was evaluated and, thus, showed that the radiographic technique had to be adjusted and the procedure as a whole had to be constantly optimized. Dates were measurement in 2007 again and after 2009. At a first moment the dose levels if had kept. In 2009 the values had come back to go up due to the increase of the load (mAs). The doses were then compared with the regulatory dose limits.
909

Estimulador galvânico vestibular para fMRI

Manczak, Tiago 30 July 2012 (has links)
Este trabalho apresenta o desenvolvimento de um estimulador galvânico vestibular para ser usado em experimentos de imageamento por ressonância magnética funcional (fMRI). Em experiências de fMRI é necessário a produção de estímulos somatossensoriais no paciente. Os estímulos devem ser sincronizados com a sequência de pulsos da fMRI. O estimulador foi dividido em circuitos analógicos (colocados dentro da sala do magneto) e circuitos digitais (sala de comando do sistema de MRI). A comunicação entre os circuitos é feita através de fibra óptica. Experimentos de fMRI realizados com voluntários demonstraram que o estimulador proposto é capaz de manter a sincronização com sistema de fMRI e pode ser usado para localizar as áreas do cérebro que são ativados pelo sistema vestibular. / This work presents the development of a galvanic vestibular stimulator to be used in functional magnetic resonance imaging experiments (fMRI). In fMRI experiments it is required the production of somatosensory stimuli in the patient must be sincronized with the fMRI pulse sequence. The stimulator circuits were divided in analog circuits (placed within the magnet room) and digital circuits (placed in the MRI command room). The communication between the circuits is made through optical fiber. fMRI experiments performed with volunteers demonstrated that the proposed stimulator is able to keep the sincronization with the MRI system and can be used to locate the brain areas that are activated by the vestibular system.
910

Estimulador elétrico neuromuscular bifásico com saída em ponte H isolada eletricamente

Gaiotto, Marcelo do Carmo Camargo 30 November 2012 (has links)
A eletrônica empregada no desenvolvimento de estimuladores elétricos funcionais contempla enorme diversificação de técnicas e tecnologias, cujas soluções para o estágio de saída variam desde circuitos transistorizados (bipolares ou MOSFETs), transformadores de pulso até amplificadores operacionais de alta tensão. Desenvolver um estimulador elétrico neuromuscular bifásico com saída em ponte H isolada eletricamente. O sistema de estimulação elétrica neuromuscular bifásico contém saída em ponte H utilizando somente transistores MOSFET canal N, permitindo a geração de pulsos bifásicos e monofásicos com controle de amplitude independente para cada pulso, por meio de uma plataforma eletrônica flexível, que possibilita sua utilização com diversos tipos de elementos de controle, desde microcontroladores e FPGA até dispositivos de instrumentação virtual do tipo LabView. Foram realizados testes de bancada que permitiram avaliar o desempenho do instrumento todo e de seus módulos separadamente. A faixa de alimentação utilizada nos testes foi de 12 a 24V, sendo relacionada diretamente a técnica de geração da alta tensão empregada que permitiu produzir de 280 V a 300 V, utilizados na ponte H, que por sua vez, apresentou o desempenho esperado fornecendo pulsos bifásicos com valores de pico a pico de até 600 V, que pudendo ter sua amplitude dos pulsos controlada individualmente com uma resolução de 73,26 mV (4096 passos), permitindo, assim, a geração de diferentes padrões estimulatórios criados a partir da interface gráfica. O estimulador projetado propiciou o desenvolvimento de uma nova técnica de saída em ponte H utilizando transistores MOSFET canal N na construção de estimuladores elétricos neuromusculares com saída bifásica e com controle de amplitude independente para cada pulso. Tal funcionalidade poderá contribuir para novos estudos e trabalhos em reabilitação empregando estimulação elétrica neuromuscular, considerando que, por meio da interface gráfica criada, formas de ondas estimulatórias específicas podem ser geradas. / The electronics used in the development of functional electrical stimulators include huge diversification of techniques and technologies, whose solutions for the output stage range from transistor circuits (bipolar or MOSFET), to pulse transformers and high-voltage operational amplifiers. To develop a biphasic neuromuscular electrical stimulator with electrically isolated H-bridge output. The electrical neuromuscular stimulation system contains biphasic H-bridge output using only N-channel MOSFET transistors, allowing the generation of mono and biphasic pulses whose pulse amplitudes are independently controlled by a flexible electronics platform, which enables its use with different types of control elements, from microcontroller and FPGA devices to Labview virtual instrument. Bench tests were performed that allowed to assess the performance of the instrument and all its modules separately. The power range used in the tests was 12 to 24V, the technique is directly related to generate the high voltage used which allowed to produce 280 V to 300 V, used in the H bridge, which in turn performed as expected providing pulses biphasic with peak to peak values of 600 V, which pudendal have its amplitude pulses individually controlled with a resolution of 73.26 mV (step 4096), thus allowing the generation of stimulatory different patterns created from the graphical interface. The project developed led the design of a new technique for H-bridge output using transistors N-channel MOSFET in the construction of biphasic neuromuscular electrical stimulator with independent amplitude control for each pulse. Such functionality can contribute to new studies and rehabilitation using neuromuscular electrical stimulation, whereas through the graphical user interface created stimulatory specific waveforms can be generated.

Page generated in 0.2163 seconds