• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 423
  • 72
  • 28
  • 10
  • 8
  • 8
  • 8
  • 8
  • 3
  • 1
  • 1
  • Tagged with
  • 533
  • 147
  • 123
  • 113
  • 111
  • 110
  • 104
  • 101
  • 88
  • 82
  • 81
  • 79
  • 56
  • 54
  • 52
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

Síntese de mulita por microondas utilizando composições contendo resíduo de caulim. / Microwave synthesis of mullite by using compositions containing waste kaolin.

BRASILEIRO, Maria Isabel. 18 September 2018 (has links)
Submitted by Maria Medeiros (maria.dilva1@ufcg.edu.br) on 2018-09-18T12:29:40Z No. of bitstreams: 1 MARIA IZABEL BRASILEIRO - TESE (PPGEP) 2010.pdf: 8318595 bytes, checksum: 08a3d5659f268dee285764bb3f8e8659 (MD5) / Made available in DSpace on 2018-09-18T12:29:40Z (GMT). No. of bitstreams: 1 MARIA IZABEL BRASILEIRO - TESE (PPGEP) 2010.pdf: 8318595 bytes, checksum: 08a3d5659f268dee285764bb3f8e8659 (MD5) Previous issue date: 2010-04-09 / Capes / A mulita 3Al2O3∙2SiO2 é uma das fases cristalinas mais extensivamente estudadas do sistema binário Al2O3 - SiO2, sendo promissora em cerâmica devido suas ótimas propriedades químicas, mecânicas e elétricas. O caulim é a fonte principal para sintetizar mulita e o resíduo de caulim, obtido a partir de uma segunda etapa do beneficiamento de caulins primários, pode apresentar teores de SiO2 e Al2O3 que permitem a sua incorporação em massas cerâmicas para a produção da mulita. Como a temperatura de reação da mulita é elevada aumentando assim seus custos, o uso da energia de microondas no processamento e obtenção de materiais, tem despertado interesse especial por parte de diversas áreas do conhecimento como a engenharia de materiais. Este interesse estar diretamente ligado ao seu simples uso, além de reduzir o número de etapas em muitas sínteses, melhorar propriedades físicas em cerâmicas tecnológicas e ter como aliado a economia de energia/tempo alcançada no processamento de muitos materiais. Neste trabalho foi feito um estudo sobre a fabricação de corpos cerâmicos de mulita a partir da mistura de resíduo de caulim e alumina, por sinterização convencional e em microondas, para efeito de comparação. Os corpos de prova foram produzidos por prensagem uniaxial na pressão de 35 MPa e sinterizados em potências de 80% (1,44 kW) e 90% (1,62 kW) com tempos de 10, 15, 20 e 25 min em forno de microondas de freqüência de 2,45GHz e no forno convencional em temperaturas de 1400 a 1600°C, com taxa de aquecimento de 5°C/min e patamar de queima de 2h. Por fim os corpos de prova foram submetidos à determinação das propriedades físico-mecânicas, caracterização de fases cristalinas por DRX e análise microestrutural por MEV. Os resultados obtidos mostraram que a mulita obtida a partir do forno de microondas apresenta estrutura das agulhas mais alongadas quando comparadas ao do forno convencional. O aumento do tempo de sinterização e da potência utilizada, no caso do forno de microondas, e que o aumento da temperatura, no forno convencional, são fatores essenciais a serem considerados para se alcançar um alto teor de mulitização. / Mullite (3Al2O3∙2SiO2) is one of the crystalline phases most extensively studied from the binary system Al2O3 - SiO2, and promising ceramic due to their excellent chemical, mechanical and electrical properties. Kaolin is the main source to synthesize mullite and kaolin waste, obtained from a second stage of processing of primary kaolin, can has contents of SiO2 and Al2O3 which allows its incorporation in ceramic bodies for the production of mullite. As the temperature of the reaction of mullite is high thus increasing their costs, the use of microwave energy for processing and obtaining materials, has attracted special interest by a number of areas as engineering materials. This interest is directly linked to its simple use, and reduce the number of steps in many synthesis, improved physical properties in ceramic technology and have the combined savings energy / time achieved in the processing of many materials. The fabrication of mullite ceramic bodies from the mixture of residual kaolin and alumina, in conventional oven and microwave, for comparison. The samples were produced by uniaxial pressure of 35 MPa and sintered in powers of 80% (1,44kW) and 90% (1,62kW) with times of 10, 15, 20 and 25 min in the microwave at frequency 2,45GHz, and conventional oven at temperatures from 1400 to 1600°C with heating rate of 5°C/min and 2h. Finally the specimens were submitted to determination of physic-mechanical characterization of crystalline phases by XRD and microstructural analysis by SEM. The results showed that the mullite obtained from the microwave oven has more elongated structure of the needles when compared to the conventional oven. The sintering time and power used in the case of microwave ovens, and that the increase of temperature in a conventional oven, are key factors to consider in achieving a high level of mullitization.
262

Influência do processamento de próteses totais maxilares com diferentes espessuras da base : análise gráfica da movimentação dos dentes artificiais /

Mazaro, José Vitor Quinelli. January 2005 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Milton Carlos Gonçalves Salvador / Banca: Humberto Gennari Filho / Banca: Eduardo Piza Pellizzer / Resumo: A relação existente entre os métodos de processamento das resinas acrílicas e a espessura de resina das bases de dentaduras, bem como a associação com o tamanho e forma do arco maxilar, tem sido um assunto bastante discutido no que diz respeito à possíveis alterações no posicionamento dos dentes e selamento posterior de próteses totais maxilares. Sendo assim, o propósito desse trabalho foi avaliar a movimentação dentária que ocorre durante o processamento de próteses totais maxilares com três diferentes espessuras de base, frente a dois métodos de inclusão e submetidas à polimerização por microondas. Quarenta e duas (42) amostras foram aleatoriamente divididas em 6 grupos de 7 amostras cada, respeitando, evidentemente, a espessura da base (1,25 mm - 2,50 mm - 3,75 mm) e o tipo de revestimento em mufla (silicone e gesso pedra). Pontos foram demarcados sobre os dentes artificiais para permitir a mensuração das R ee ssum o amostras através do software AutoCad. A diferença das médias dos segmentos entre o modelo encerado e demuflado de cada grupo foi submetida à analise de variância (ANOVA) e teste de Tukey. De acordo com os resultados obtidos pode-se concluir que: todas as técnicas de processamento juntamente com as diferentes espessuras de base de prótese total avaliadas apresentaram alteração na posição dos dentes artificiais após o processamento. A técnica de inclusão com barreira de silicone foi a que apresentou as maiores alterações dimensionais, independentemente da espessura. Na análise dos segmentos, houve uma maior alteração dos segmentos A/B/C (Triângulo maior) com relação aos segmentos D/E/F (Triângulo menor). Independente do tipo de inclusão, não houve diferença estatística entre as espessuras das bases (p<0,059), entretanto, analisando o comportamento de alteração, as prótese totais com bases mais finas apresentaram maior... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The existent relationship between the methods of processing of the acrylic resins and the thickness of dentures bases resin, as well as the association with the size and form of the maxillary arch, it has been a subject quite discussed with regard to possible alterations in the teeth positioning and maxillary complete denture postdamming. So that, the aim of the study was to evaluate the dental movement that it happens during the processing of maxillary complete dentures with three base thickness different, front of two inclusion methods and submitted to the microwaves polymerization. Forty two (42) samples were randomly divided in 6 groups of 7 samples each, respecting, evidently, the base thickness (1,25 mm - 2,50 mm - 3,75 mm) and the type in flask investment (silicone and plaster stone). Points were demarcated on the artificial teeth to allow the measurement of the samples through the AutoCad software. The averages difference of the segments between the Ab ss tt rr a cc tt waxed model and deflasked of each group was submitted to it analysis of variance (ANOVA – á=0,05) and Tukey test. In agreement with the obtained results it can be conclusion that: all the processing techniques together with the different thickness of complete denture base evaluated, presented alteration in the artificial teeth positionig after the processing. The silicone flasking technique was that presented the largest dimensional alterations, independently of the thickness. In the segments analysis, there was a larger alteration of the segments A/B/C (larger Triangle) regarding the segments D/E/F (smaller Triangle). Independent of the flasking type, there was not difference statistics among the thickness of the bases (p <0,059), however, analyzing the alteration behavior, thinner bases presented larger movement in the position of the artificial teeth than thicken base that complete denture them. The completed... (Complete abstract, click electronic address below). / Mestre
263

Efeito da calcinação da magnésia precipitada sobre o processamento de cimentos de fosfato de magnésio. / Calcination effect of precipated magnesia on the processing of magnesia phosphate cements.

Paula, Gustavo Rocha de 20 December 2004 (has links)
Made available in DSpace on 2016-06-02T19:10:13Z (GMT). No. of bitstreams: 1 TeseGRP.pdf: 18239191 bytes, checksum: de0d3db98bc2bc440699f5c776c8abca (MD5) Previous issue date: 2004-12-20 / Universidade Federal de Sao Carlos / It is great the interest for materials synthesized at room temperature because they represent an alternative for the current problems of energy. The class of magnesia phosphate cements belongs to this group, being mouldable ceramics that combine low density and good mechanical strength in a short period of time. The main disadvantage of these materials resides in their cost, even high if compared to Portland cement. The calcination stage of the magnesium oxide (MgO), necessary due to the high reactivity of that oxide with phosphates, is especially costly, besides the need of the addition of retardants to increase the setting time of these cements. The present work aimed to study forms of increasing the setting time of these cements and to evaluate alternatives to decrease the calcination temperature of MgO powders. Techniques such as X ray diffraction, infrared spectroscopy, scanning electronic microscopy, Hg porosimetry, He picnometry, and analyses of particle size distribution, specific surface area, apparent density and compression strength were used for the characterization of the calcined MgO powders and the cements. In a scientific-technological point of view, the main contribution of this work was the use of both liquid phase former additives and the microwave radiation for the calcination of MgO. In these conditions powders with appropriate particle size distributions and low specific surface areas were produced, which led to cements with longer reaction time and high mechanical strength. The microwave assisted calcination of MgO powders at 900 oC, with microwave absorbing raw materials, resulted in cements with superior properties when compared to those ones produced with powders calcined in conventional furnaces at 1100 oC. Another advantage was a heating rate five times faster and the temperature dwell four times shorter than those ones used in conventional firing. Such facts demonstrate the promising use of additives and the microwave firing to decrease the temperature of calcination of MgO and optimize the properties of magnesia phosphate cements. / É grande o interesse por materiais sintetizados a temperatura ambiente, pois representam uma alternativa para os atuais problemas de energia. Deste grupo faz parte a classe dos cimentos de fosfato de magnésio, cerâmicas moldáveis que combinam baixa densidade e boa resistência mecânica em curtos intervalos de tempo. A principal desvantagem destes materiais reside em seu custo, ainda elevado se comparado ao cimento Portland. A etapa de calcinação do óxido de magnésio (MgO), necessária devido a elevada reatividade desse óxido com fosfatos é sobretudo onerosa, sem falar da necessidade da adição de retardantes afim de aumentar o tempo de pega destes cimentos. O presente trabalho teve como objetivos estudar formas de se aumentar o tempo de pega destes cimentos, e avaliar alternativas para se diminuir a temperatura de calcinação do MgO. Para tanto foram utilizadas as técnicas de difratometria de raios X, espectroscopia de infravermelho, microscopia eletrônica de varredura, porosimetria de Hg, picnometria de He, e medidas de distribuição de tamanhos de partículas, área superficial específica, densidade aparente e resistência mecânica a compressão para caracterização dos pós de MgO e dos cimentos. Sob o ponto de vista cientifico-tecnológico, a principal contribuição deste trabalho foi o emprego tanto de aditivos formadores de fase líquida quanto do forno de microondas para a calcinação do MgO. Nessas condições foram obtidos pós com adequada distribuição de tamanhos de partículas e baixa área superficial, que levaram a cimentos com maior tempo de reação e alta resistência mecânica. A calcinação do MgO em microondas à 900 oC, na presença de matérias primas absorvedoras desta radiação, resultou em cimentos com propriedades superiores aos obtidos com pós calcinados em forno convencional em temperaturas da ordem de 1100 oC. Outra vantagem foi a utilização de uma taxa de aquecimento cinco vezes maior e um tempo de patamar quatro vezes menor comparada à queima convencional. Tal fato vem a demonstrar o uso promissor da aditivação e da queima em forno de microondas para a diminuição da temperatura de calcinação do MgO e otimização das propriedades dos cimentos de fosfato de magnésio.
264

Adaptação de forno micro-ondas doméstico para preparação de poliedros oligoméricos silsesquioxanos - POSS

Penso, Igor Luiz 08 June 2015 (has links)
Materiais híbridos, como poliedros oligoméricos silsesquioxanos (POSS), têm recebido especial atenção nos últimos anos pois são materiais que possuem uma combinação sinérgica de propriedades de materiais orgânicos e inorgânicos. Sua preparação necessita de elevados tempos de síntese e o uso de aquecimento dielétrico se apresenta promissor. Entretanto, reatores comerciais são caros e uma alternativa passa a ser a adaptação de fornos de uso domésticos. Neste contexto, este trabalho busca adaptar um forno de micro-ondas doméstico para a síntese de POSS, comparando materiais obtidos via aquecimento por microondas e convencional (banho em óleo). O POSS foi sintetizado através da condensação hidrolítica do viniltrietoxisilano (VTES) e da mistura VTES e tetraetil ortosilicato (TEOS). As amostras sintetizadas foram caracterizadas por FTIR, RMN de 1H, TGA, GPC, MEV, MET e DRX. O uso de micro-ondas possibilitou a obtenção de POSS com maior rendimento para os sistemas VTES e VTES/TEOS, apresentando taxas de reação respectivas de 47 e 59 vezes maior que a síntese convencional. Todas as amostras apresentaram bandas FTIR intensas em ~1090 e ~568 cm-1, ambas relacionadas a formação de gaiolas de silsesquixanos. Não foram observadas vibrações -O-CH2CH3 mostrando que a reação de hidrólise foi totalmente completa. A presença de deformações OH nas amostras VTES/TEOS indica a formação de estruturas não totalmente condensadas, confirmada pelos espectros de RMN de H1 onde é observada a presença de silanóis não condensados. Análises GPC para o POSS VTES apresentaram a maior fração (96,5%) de estruturas T8 via convencional, e (93,93%) via micro-ondas. A adição de TEOS reduziu a fração de estruturas T8 obtidas, (78,0%) via dielétrico e (33,0%) convencional. A análise TGA de todas as amostras mostraram uma única etapa de degradação, onde diferenças observadas no sistema VTES/TEOS são associadas ao tamanho da estrutura do POSS conforme a análise de GPC. Imagens de MEV mostraram a presença de estruturas cúbicas e esféricas em todas as amostras, e a adição de TEOS indicou uma tendência a redução de tamanho. Imagens por MET para o POSS VTES mostrou morfologia similar as observadas por MEV, e para VTES/TEOS, a presença de aglomerados esféricos regulares nanométricos. O DRX para o POSS VTES micro-ondas, convencional e VTES/TEOS micro-ondas, indicou a presença de uma rede cristalina de estrutura romboédrica, típica de POSS T8. O POSS VTES/TEOS via convencional apresentou um padrão de DRX de uma amostra amorfa. As nanopartículas híbridas de POSS VTES, via aquecimento convencional e dielétrico em refluxo, mostrou possuírem características químicas muito semelhantes, confirmadas pelas técnicas de análise realizadas. Entretanto, a mesma comparação entre o POSS obtido via mistura VTES/TEOS, a mesma semelhança não é observada. Isto se deve ao precursor VTES ser trifuncional e ao TEOS ser tetrafuncional, ou seja, possuem momentos dipolares diferentes, induzindo estruturas irregulares orientadas aleatoriamente e de diferentes tamanhos, principalmente no aquecimento convencional, onde a reação apresentada é mais lenta. / Submitted by Ana Guimarães Pereira (agpereir@ucs.br) on 2015-09-14T18:28:06Z No. of bitstreams: 1 Dissertacao Igor Luiz Penso.pdf: 3673859 bytes, checksum: f0f80b6c32267df60b2b04fa4df6d307 (MD5) / Made available in DSpace on 2015-09-14T18:28:06Z (GMT). No. of bitstreams: 1 Dissertacao Igor Luiz Penso.pdf: 3673859 bytes, checksum: f0f80b6c32267df60b2b04fa4df6d307 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior. / Hybrid materials, such as polyhedral oligomeric silsesquioxanes (POSS), nowadays have received special attention because they are materials that have a synergistic combination of organic and inorganic materials properties. Their preparation requires high time of synthesis and the use of dielectric heating appears promising. However, commercial reactors are expensive and the adaptation of domestic microwave ovens becomes an alternative. In this context, this work aims to adapt a domestic microwave oven for the synthesis of POSS, comparing materials obtained by microwave and conventional (oil bath) heating. The POSS was synthesized by the hydrolytic condensation of vinyltriethoxysilane (VTES) and tetraethyl orthosilicate (TEOS) in different proportions. The synthesized samples were characterized by FTIR, 1H-NMR, TGA, GPC, SEM, TEM and XRD. The use of microwaves enable the manufacture of POSS with increased yield for VTES and VTES/TEOS systems, respectively with rates of 47 to 59 times higher than conventional synthesis. All samples showed intense FTIR bands at ~ 1090 and ~ 568 cm-1, both related to formation of silsesquioxane cages. It was not observed -O-CH2CH3 vibrations showing the hydrolysis reaction has been fully completed. The presence of OH deformations in the VTES/TEOS samples indicate the formation of non-fully condensed structures, confirmed by 1H NMR spectra, where it is observed the presence of non-condensing silanol. GPC analysis for the POSS VTES exhibited a major fraction (96.5%) of T8 structures via conventional, and (93.9%) via microwave synthesis. The addition of TEOS decreased the fraction of T8 structures, (78.0%) via dielectric and (33.0%) for conventional synthesis. TGA analysis of all samples showed a single stage of degradation, differences between VTES/TEOS samples are associated with the size of the POSS structure according to GPC analysis. SEM images showed the presence of spherical and cubic structures in all samples, and the addition of TEOS indicated a tendency to increase the size of these structures. TEM images for POSS VTES showed similar morphology to those observed by SEM. The presence of nanometric regular spherical agglomerates was observed in VTES/TEOS samples. The XRD for POSS VTES microwave, conventional and VTES/TEOS microwave synthesis, indicated the presence of rhombohedral lattice structure, typical POSS T8. The POSS VTES/TEOS conventional route showed a XRD pattern of an amorphous sample. The hybrid nanoparticles of POSS VTES, prepared via conventional and dielectric heating using reflux system, showed a very similar chemical properties as confirmed by the analytical techniques performed. However, the same comparison between the POSS obtained via mixing of VTES/TEOS, the same behavior is not observed. This is due to the VTES precursors be trifunctional and TEOS tetrafunctional, i.e. have different dipole moments, inducing randomly oriented irregular structures and different sizes, especially in the conventional heating where reaction is slower.
265

Esterelização de esmalte bovino por meio de irradiação por microondas: efeito sobre a microdureza superficial e resistência à desmineralização

Viana, Patricia Gabriela Sabino [UNESP] 27 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-27Bitstream added on 2014-06-13T19:17:33Z : No. of bitstreams: 1 viana_pgs_me_arafo.pdf: 840842 bytes, checksum: 18e582ab40c3b9552459a495ba07430b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Amostras de esmalte provenientes de dentes extraídos, de origem humana ou bovina, são amplamente utilizadas em estudos realizados in vitro e in situ. Esses dentes são considerados uma fonte em potencial de microorganismos patogênicos e devem ser esterilizados, antes da sua utilização nas pesquisas, para prevenir a ocorrência de infecções cruzadas. No entanto, o processo de esterilização do esmalte não deve alterar a sua integridade estrutural. O presente estudo teve como objetivo avaliar a efetividade da irradiação por microondas na esterilização do esmalte bovino, assim como o efeito deste método sobre a microdureza superficial e resistência à desmineralização do esmalte bovino. Dezoito incisivos bovinos foram utilizados para a obtenção de quarenta amostras de esmalte, divididas em dois grupos (n=20): controle (não-irradiados) e irradiados por microondas (3 minutos a 650 W). As amostras do grupo irradiado foram imersas, individualmente, em 200 mL de água destilada e submetidas à irradiação por microondas por 3 minutos a 650 W. Em seguida, ambos os grupos tiveram suas amostras imersas individualmente em tubos estéreis contendo 10 mL caldo BHI (Brain Heart Infusion), os quais foram incubados por 7 dias a 37°C, sob condições de aerobiose e anaerobiose. Após a incubação, o desenvolvimento de microorganismos foi verificado pela presença de turvação do meio de cultura. Em seguida, foram realizadas diluições seriadas (10-2 a 10-5), plaqueamento em meio ágar sangue e incubação em condições de aerobiose e anaerobiose, durante 48 h e 7 dias, respectivamente. Os valores de unidades formadoras de colônias foram calculados. Para a avaliação das propriedades do esmalte, outras 18 amostras de esmalte (4 x 4 mm) foram preparadas, individualmente embutidas em resina acrílica, seqüencialmente polidas e, então, seccionadas em duas metades, sendo uma das metades... / Enamel samples from bovine or human teeth are routinely used for in vitro and in situ caries research. These enamel samples need to be sterilized before they can be used in intra-oral appliances and the sterilization method must not affect the structural integrity of the tooth. The aim of this study was to evaluate the effectiveness of microwave irradiation on bovine enamel sterilization, as well as it's effect on the surface microhardness and resistance to demineralization of bovine enamel. Eighteen bovine incisors were used to produce forty enamel samples, divided in two groups (n = 20): control (nonirradiated) and microwave irradiated (3 minutes at 650 W). Microwaving samples were individually immersed in 200 mL of distilled water and submitted to irradiation at 650 W for 3 minutes. Following the microwaving, specimens from both groups were added individually to 10 mL of Brain Heart Infusion broth in sterile test tubes, which were incubated at 37°C for 7 days under aerobic and anaerobic conditions. After 7 days incubation, those test tubes in which turbidity was observed were considered to contain growing microorganisms. Dilutions of 10-2 to 10-5 were performed on blood agar plates, which were incubated aerobically and anaerobically for growth for up to 48 h and 7 days, respectively. After incubation, the numbers of colonyforming units were calculated. For the properties of enamel analysis, other 18 bovine enamel samples (4 x 4 mm) were prepared, embedded in acrylic resin, serially polished and sliced into two halves: one of the fragments was reserved as control while the other was microwaved in 200 mL of distilled water for 3 minutes at 650 W. Hardness measurements were conducted using a Microhardness tester with a Knoop diamond. Five indentations were performed under a load of 25 gf for 05 seconds. For the resistance to demineralization analysis, the groups were submitted... (Complete abstract click electronic access below)
266

Efeito de desinfecções sucessivas com energia de microondas na resistência de união entre dentes artificiais e resinas para bases de próteses

Chuqui, Roberta [UNESP] 28 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-28Bitstream added on 2014-06-13T18:38:57Z : No. of bitstreams: 1 chuqui_r_me_arafo.pdf: 5214724 bytes, checksum: 7fcde9af460bda49c5c01007a97620cc (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo avaliou o efeito de desinfecções sucessivas por meio da utilização de microondas sobre a resistência de união entre dentes artificiais (incisivos centrais superiores: Biotone - DB, modelo 264 e Vivodent - DV, modelo A15) e resinas para bases (QC20 - QC, Acron MC - AC e Lucitone 550 - L). Os dentes artificiais foram posicionados em anéis de PVC (20 mm de diâmetro e 20 mm de altura) preenchidos com cera. Cada anel foi incluído em silicone por condensação para facilitar posteriormente a remoção das amostras polimerizadas. Esses moldes de silicone foram então incluídos em mufla dental com gesso. A cera foi eliminada com água em ebulição, sendo o molde preenchido com resina acrílica, manipulada e polimerizada de acordo com as instruções do fabricante. Quarenta corpos-de-prova foram obtidos para as três resinas de base com as duas marcas de dentes avaliados. Todas as amostras foram divididas aleatoriamente em quatro grupos. G1 (controle) - amostras imersas em água destilada a 37ºC por 48 horas; G2 - imersas por 48 horas e submetidas a dois ciclos de desinfecção por 6 minutos a 650 W; G3 - imersas por 48 horas em água destilada e submetidas a sete ciclos de desinfecção (um por dia) por 6 minutos a 650 W, estando as amostras imersas em água a 37ºC entre as desinfecções; G4 - imersas em água destilada por 8 dias (controle). O teste de cisalhamento foi realizado em máquina de ensaios MTS - 810 com a força aplicada na superfície palatina dos dentes em ângulo de 45º e velocidade de 0,5 mm/min. As superfícies de fratura foram observadas em lupa esteroscópica com um aumento de 10 vezes para determinar a natureza da falha (adesiva, coesiva ou mista). Adicionalmente, foi realizada microscopia eletrônica de varredura. Os dados (MPa) foram analisados utilizando ANOVA, teste de Tukey e teste t de Student (P=0,05)... / This study evaluated the effect of microwave disinfection on the bond strength of denture teeth (maxillary central incisors: Biotone - DB, model 264 and Vivodent - DV, model A15) to acrylic resins (QC20 - QC, Acron MC - AC and Lucitone 550 - L). Denture teeth were positioned within polyvinylchloride tubes (20 mm diameter and 20 mm length) filled with melted wax. The tubes were invested in silicone rubber to facilitate removal of the processed specimens from the flask. These silicone moulds were then invested in the usual denture flasks in dental stone. The wax was boiled out, the mould was packed with denture resin and polymerized according to the manufacturer's instructions. Forty specimens were formed from each of the three denture base resin with the two brands of denture teeth. All specimens were randomly divided into four groups to provide a sample size of 10. G1 (control group) - immersed in distilled water at 37ºC for 48 hours; G2 - immersed in distilled water at 37ºC for 48 hours and microwaved twice at 650W for 6 minutes; G3 - immersed in distilled water at 37ºC for 48 hours and microwaved (650 W for 6 minutes) daily for 7 days, being stored in water at 37ºC between exposures; G4 (control group) - immersed in distilled water at 37ºC for 8 days. Shear load was applied with a load testing machine at 45 degrees from the long axis of each denture tooth on the palatal surface at a crosshead speed of 0.5mm/min until fracture. Fracture surfaces were evaluated with an optical stereomicroscope under x 10 magnifications to determine the nature of the failure (adhesive, cohesive or combination). In addition, a representative sample of each experimental group was evaluated with a scanning Electron Microscopy (SEM). The data (MPa) were analyzed statistically using 3-way ANOVA, Tukey's test and Student's t test (P=0.05)...(Complete abstract, click electronic address below)
267

Efeito da irradiação por microondas sobre as propriedades viscoelásticas de resinas para base de prótese e reembasamento

Lombardo, Carlos Eduardo Leão [UNESP] 25 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-25Bitstream added on 2014-06-13T19:38:22Z : No. of bitstreams: 1 lombardo_cel_me_arafo.pdf: 3996119 bytes, checksum: c7eb8e08977bab50ee60b2bacfeaab4e (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo avaliou o efeito da irradiação por microondas e da armazenagem em água sobre as propriedades viscoelásticas de duas resinas para base de prótese (Lucitone 550- L e Vipi Wave- VW) e duas resinas para reembasamento imediato (Kooliner- K e Tokuyama Rebase Fast II- TR II). Oito corpos-de-prova (40 x 10 x 3,3 mm) de cada material foram avaliados por meio de análise térmica dinâmico-mecânica (DMTA) após: acabamento (controle 1), armazenagem em água por 7 dias (controle 2), um (MW1) e 7 ciclos de irradiação por microondas (MW7). Para cada corpo-de-prova, ciclos de DMTA foram realizados dentro de intervalos de temperatura diferentes. Os valores do módulo de armazenamento (E’) e de amortecimento mecânico (tan δ) a 37ºC foram obtidos no primeiro e último ciclos de DMTA. A partir do último ciclo, os valores de E’ na temperatura de transição vítrea (Tg) e o máximo de tan δ também foram obtidos. Os dados foram submetidos à análise de variância a dois critérios e ao teste de Student-Newman-Keuls (α=0,05). Além disso, mensurações de temperatura no interior de corpos-de-prova de cada material, durante a irradiação por microondas (650 W/ 3 min), foram realizadas por meio da utilização de sensor de fibra óptica. Seis corpos-de-prova de cada material foram avaliados. Durante a irradiação por microondas, todos os corpos-de-prova atingiram a temperatura de ebulição da água em aproximadamente 130 s. A partir do primeiro ciclo de DMTA, MW 1 e controle 2 aumentaram significantemente os valores de E’ e reduziram os valores de tan δ de K a 37ºC (P<0,05). No último ciclo de DMTA, o tan δ de K e TR II foi significantemente reduzido após MW1 (P<0,05). MW7 reduziu os valores de tan δ de K (P<0,05). Os valores de E’ de L e VW foram semelhantes entre si e superiores aqueles produzidos por K e TR II (P<0,05). Na Tg, K produziu o menor E’ e seu máximo... / This study evaluated the effect of microwave irradiation and water storage on the viscoelastic properties of two denture base resins (Lucitone 550-L and Vipi Wave-VW) and two reline resins (Kooliner-K and Tokuyama Rebase Fast II-TR II). Eight specimens (40x10x3.3mm) of each material were evaluated by dynamic mechanical thermal analysis (DMTA) after: processing, water storage for 7 days (WS), one (MW1) and 7 cycles of microwave irradiation (MW7). For each specimen, DMTA runs were carried out within different temperature intervals. Values of storage modulus (E’) and loss tangent (tan δ) at 37ºC were obtained from the first and last runs. From the last run, values of E’ at the glass transition temperature (Tg) and maximum tan δ were also recorded. Data were analyzed by 2-way ANOVA followed by Student-Newman-Keuls test (α=0.05). In addition, measurements of the inside temperature of each specimen during microwave irradiation (650W/3min) were conducted using a fiber optic temperature sensor. Six specimens of each material were evaluated. During microwave irradiation, all specimens reached the boiling temperature of water at approximately 130 s. From the first DMTA run, MW1 and WS significantly increased the E’ and decreased the tan δ of K at 37°C (P<0.05). From the last run, the tan δ of K and TR II was significantly decreased after MW1 (P<0.05). MW7 decreased the tan δ of K (P<0.05). The E’ of L and VW was similar and higher than K and TR II (P<0.05). At Tg, K produced the lowest E’ and its maximum tan δ was increased after MW1 (P<0.05). The Tg mean values were arranged as: L>VW>TR II>K (P<0.05). Microwave irradiation and WS did not detrimentally affect the viscoelastic properties of the denture base and reline resins evaluated.
268

Análise morfológica e de resistência à flexão da interface ponta ativa/haste metálica em fresas carbide após o uso de esterilização /

Marcelo, Caroline Canhizares. January 2007 (has links)
Orientador: Regina Helena Barbosa Tavares da Silva / Banca: Lígia Antunes Pereira Pinelli / Banca: Paulo Martins Ferreira / Resumo: Na prática odontológica os rigores de controle de infecção exigem do cirurgião-dentista procedimentos de esterilização e desinfecção sobre seus instrumentos para prevenir a infecção cruzada, porém, esses procedimentos podem levar à oxidação e, portanto, determinar o aparecimento de corrosão nos instrumentos rotatórios cortantes. Considerando as questões que têm sido levantadas sobre o efeito dos vários métodos de esterilização sobre a eficiência de corte e resistência dos instrumentos dentais, este trabalho teve como objetivo avaliar possíveis alterações morfológicas e também alterações na resistência de união ocorridas entre a ponta ativa/ haste metálica em fresas carbide causadas pelo uso e procedimentos de esterilização. Para tanto foram utilizadas 130 fresas carbide que foram divididas em grupos de acordo com o tratamento aplicado: controle, autoclave, estufa, microondas e glutaraldeído. Depois de completado o teste experimental proposto, todos os grupos foram submetidos ao teste de resistência à flexão. Foi realizada também análise morfológica (qualitativa) das fresas por fotomicrografias capturadas por meio de uma lupa estereoscópica LEICA com o software. Os dados foram devidamente anotados e submetidos à análise estatística com testes de Kruskal-Wallis e Dunn. Os resultados, tanto da avaliação morfológica quanto da resistência à flexão, mostraram que somente o grupo do glutaraldeído se comportou de maneira diferente do grupo controle, havendo diferença estatística significante entre esses dois grupos. E, os demais grupos foram estatisticamente semelhante ao grupo controle. Pode-se concluir que nenhum método físico de esterilização estudado (autoclave, estufa e microondas) influenciou negativamente as características morfológicas e a resistência de união da interface ponta ativa/haste metálica... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Such as in all professions related to health, in dentistry there are necessary procedures which limit or obstruct disease propagation through clinical practice. Among such procedures is the sterilization of rotary instruments to prevent the risk of cross-infection. Each day in clinical practice, physical and chemical methods of sterilization can corrode appearance. The presence of corrosion on rotary cutting instruments makes them unusable. Concerning questions that have been raised on effect of some sterilization methods on the cutting efficiency and dental instruments resistance, this paper aimed to evaluate the influence of cutting time, sterilization methods and the amount of sterilization cycles in morphologic alterations and fracture resistance between the cutting head/ steel shank of carbide burs. An in vitro study was carried out in which one hundred-thirty tungsten-carbide burs were divided into five groups in accordance with sterilization method: control; autoclave; dry heat; microwave and glutaraldehyde. Glass plates were cut for 2.5 minutes by each bur attached to a high-speed handpiece with an intermittent load of 0.68N. After cutting time, burs were cleaned, dried, and submitted to a sterilization method corresponding to each group. Each cutting time or sterilization cycles, the visual accompaniment of the burs and photographed under a stereomicroscope. All groups were submitted to the flexure strength test at the end of a stipulated time in the mechanical rehearsals machine, MTS. Results obtained were submitted to the Kruskal-Wallis test and Dunn, which showed that only the group of glutaraldeído had difference significant statistics of the control group and the another groups (autoclave, dry heat and microwave) had been statistical similar to the control group, in both the morphologic evaluation and the fracture resistance. It may be... (Complete abstract, click electronic access below) / Mestre
269

Efeito do tratamento térmico em microondas e do tempo de armazenamento em água sobre a citotoxicidade de resinas acrílicas para base e reembasamento de próteses /

Jorge, Janaina Habib. January 2006 (has links)
Resumo: A proposta do presente estudo foi avaliar, por meio do teste quantitativo de incorporação de 3H-timidina, o efeito do tratamento térmico em microondas sobre a citotoxicidade de três resinas termopolimerizáveis indicadas para confecção de bases de próteses, em função do tempo de armazenamento em água, e de três resinas autopolimerizáveis indicadas para reembasamento. A hipótese de que o tratamento térmico em microondas poderia diminuir a citotoxicidade de resinas acrílicas foi avaliada. Os materiais testados foram Lucitone 550 (a mufla foi imersa em água à temperatura de 730C permanecendo por 90 minutos, em seguida, à temperatura foi elevada para 1000C e a mufla mantida por mais 30 minutos), QC 20 (a mufla foi imersa em água em ebulição, o aquecimento foi mantido e a mufla permaneceu no recipiente por um período de 20 minutos contados a partir do momento em que a água atingiu novamente à temperatura de ebulição e Acron MC (a mufla foi levada ao forno de microondas durante 3 minutos à potência de 500 W) e os reembasadores Tokuyama Rebase II, Kooliner e New Truliner. Foram confeccionados, em condições assépticas, corpos-de-prova de cada resina em forma de discos medindo 10 mm de diâmetro e 1 mm de espessura. As amostras das resinas termopolimerizáveis foram armazenadas em água destilada por 0, 24 ou 48 horas a 37ºC. Para avaliar o efeito do tratamento térmico em microondas, os corpos-de-prova de todas as resinas foram divididos em dois grupos: 1) sem tratamento térmico e 2) com tratamento térmico em microondas, com as amostras imersas em água, irradiadas durante 3 minutos à 500 W. Os extratos das resinas foram preparados colocando-se três corpos-de-prova de cada grupo experimental, após terem recebido o tratamento térmico, em tubos de ensaio com 9 ml de meio de cultura Eagle e incubados a 37ºC por 24 horas. Um tubo de ensaio, contendo apenas 9 ml de meio... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of the current study was to evaluate the effect of microwave post-polymerization heat-treatments and water storage time on the cytotoxicity of denture base and reline acrylic resins. The hypothesis that post-polymerization treatment could decrease the cytotoxicity of acrylic base resins was tested in this study. The materials tested were Lucitone 550 (water-bath at a temperature of 73ºC for 90 minutes, followed by 30 minutes of heating at 100ºC), QC 20 (boil water, insert flask, return to boil, boil for 20 minutes) and Acron MC (microwave-polymerized, irradiated for 3 minutes at 500 W) and the hard chair-side reline resin Tokuyama Rebase II, Kooliner and New Truliner. Sample disks of the denture base resins were fabricated under aseptic conditions in mold 10 mm in diameter by 1 mm thick. The samples of the denture base acrylic resins were stored in distilled water for 0, 24 and 48 hours at 37ºC. To assess the biologic effect of the heat-treatment on the denture resins, samples fabricated were further divided into two groups: 1) samples without heat-treatment; and 2) sample were treated in microwave, immersed in water, irradiated for 3 minutes at 500 W. Eluates of the materials were prepared by placing three disks into a sterile glass vial with 9 ml of Eagle's medium supplemented with antibiotics and fetal bovine serum. These were incubated for 24 hours at 37ºC. Medium without disks was also incubated and diluted as above to serve as the control. L929 mouse fibroblasts (1 x 104 cell/ml) were cultivated in Eagle's medium supplemented with antibiotics and fetal bovine serum in 96 well culture plates and incubated for 24 hours at 37ºC in an air atmosphere containing 5% CO2. After 24 hours of incubation, the culture medium was replaced by 50 ml of eluate and 50 ml of fresh medium were added to each well of the 96-well culture plate and incubated for more... (Complete abstract, click electronic address below) / Orientador: Eunice Teresinha Giampaolo / Coorientadora: Iracilde Zeppone Carlos / Banca: Ana Cláudia Pavarina / Banca: Carlos Eduardo Vergani / Banca: Ricardo Faria Ribeiro / Banca: Wellington Cardoso Bonachela / Doutor
270

Análise da variação da posição dos dentes artificiais durante as fases específicas do processamento de próteses totais superiores mensurada por computação gráfica /

Shibayama, Ricardo. January 2006 (has links)
Orientador: Humberto Gennari Filho / Banca: Alcides Gonini Júnior / Banca: Marcos Frossard / Banca: Marcelo Coelho Goiato / Banca: Eduardo Piza Pellizzer / Resumo: Foi investigada a alteração da posição dos dentes artificiais durante o processamento de próteses totais desde a fase de enceramento até o polimento, utilizando as resinas de marcas comerciais QC 20 (Dentsply) e Onda Cryl (Clássico - específico para microondas), com inclusão em gesso tipo II e com muralha de silicone, polimerizadas tanto pelo método de banho em água quente, quanto pela polimerização por energia de microondas. Foram utilizadas 40 amostras, obtidas de um modelo padrão e divididas em 4 grupos de 10, que receberam os seguintes tipos de processamento. a) grupo 1: incluídos em muflas metálicas com muralha de gesso pedra e polimerização por banho de água quente. b) grupo 2: incluídos em muflas de fibra de vidro com muralha de gesso pedra e polimerização por microondas. c) grupo 3: incluídos em muflas metálicas com muralha de silicone e polimerização por banho em água quente. d) grupo 4: incluídos em muflas de fibra de vidro com muralha de silicone e polimerização por energia de microondas. Para detecção dos deslocamentos dentais utilizou-se um guia de resina acrílica com 5 pontos pré-determinados nas cúspides dos dentes que proporcionaram pontos de referência nas réplicas permitindo mensurar tais deslocamentos através da digitalização das superfícies oclusais dos dentes e analisados por um programa de computador "AutoCad". Baseados nos resultados obtidos, de acordo com os materiais e metodologia empregados, concluimos que: 1. Em todas as técnicas de processamento de prótese total estudadas houve alteração da posição dos dentes após o processamento. 2. A técnica de inclusão com muralha de silicone e polimerização por microondas (grupo 4) apresentou os menores valores de alterações na posição dos dentes durante toda a fase de processamento... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Artificial teeth position changes were investigated during the upper complete denture processing, resins QC 20 (Dentsply) and Onda Cryl (Clássico - specific for microwave energy) were used and flasked in type II gypsum stone mould or silicone mould, polymerized in hot water bath as well in microwave polymerization. Forty specimens were used, which were obtained from one standard cast, and divided into four groups of ten that were processed as the following: a) group I (control): flasked in metallic muffles with gypsum stone barrier and conventional polymerization. b) group II: flasked in glass fiber muffles with gypsum stone barrier and polymerization by microwave energy. c) group III: flasked in metallic muffles with silicone barrier and conventional polymerization. d) group IV: flasked in glass fiber muffles with silicone barrier and microwave polymerization. An acrylic resin guide was used to detect teeth displacements, this guide was marked with 5 predetermined points in teeth cuspids that has proportionate reference points in the replicas. These points were used to measure, by AutoCad software, teeth displacements by digitized occlusal surface of the teeth. Based upon the results, according to the employed material and method, the following can be concluded: 1. It was observed teeth position changes after denture processing in all experimental groups. 2. The technique of flasking with silicone mould and microwave polymerization (group 4) presented minor degree of teeth position changes during all the processing. 3. The segments that constitute the smaller triangle represented by the points of teeth 15, 21 and 25 showed more homogeneity and linearity than the bigger triangle represented by the cuspids of 17, 21 and 27. 4. These dimensional changes of shrinkage and expansion in both triangles followed a uniform sequence for all the segments, that is, as one segment changes, the others follow it, thus, they don’t occur randomly. / Doutor

Page generated in 0.021 seconds