• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 57
  • 2
  • Tagged with
  • 59
  • 46
  • 42
  • 37
  • 35
  • 33
  • 25
  • 21
  • 19
  • 19
  • 18
  • 17
  • 15
  • 14
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Desenvolvimento de procedimentos analíticos limpos e com alta sensibilidade para a determinação de espécies de interesse ambiental / Development of clean analytical procedures with high sensitivity for determination of species of environmental interest

Wanessa Roberto Melchert 28 May 2009 (has links)
Procedimentos analíticos limpos e com alta sensibilidade foram desenvolvidos para a determinação de espécies de interesse ambiental (carbaril, sulfato e cloro livre). Os procedimentos foram baseados no acoplamento de sistemas de análises em fluxo com microbombas solenoides à espectrofotometria com longo caminho óptico ou em procedimentos de extração em ponto nuvem, visando a concentração das espécies de interesse sem o emprego de solventes tóxicos. A determinação de carbaril em águas naturais foi baseada em uma dupla extração em ponto nuvem: uma etapa de clean-up para a remoção de substâncias orgânicas interferentes e outra de pré-concentração do indofenol formado na reação com a forma oxidada do p-aminofenol. Resposta linear foi observada entre 10 e 500 µg L-1, com absortividade molar aparente estimada em 4,6x105 L mol-1 cm-1. O limite de detecção foi estimado em 7 µg L-1 e coeficiente de variação em 3,4% (n = 8). Recuperações entre 91 e 99% foram estimadas para adições de carbaril em amostras de águas naturais. Uma cela simples e de baixo custo com 30 cm de caminho óptico foi construída para medidas espectrofotométricas. A cela apresenta características desejáveis como baixa atenuação do feixe de radiação e volume interno (75 µL) comparável a de uma cela convencional. O desempenho da cela foi avaliado na determinação de fosfato utilizando o método azul de molibdênio com resposta linear obtida entre 0,05 e 0,8 mg L-1 de fosfato (r = 0,999). O aumento na sensibilidade (30,4 vezes) em comparação com o obtido com uma cela de fluxo convencional de 1 cm está de acordo com o estimado pela lei de Lambert-Beer. A formação do indofenol foi também explorada para a determinação de carbaril no procedimento em fluxo com celas de 30 e 100 cm. Respostas lineares; limite de detecção e coeficiente de variação foram estimados entre 50 - 750 e 5 - 200 µg L-1; 4,0 e 1,7 µg L-1 e 2,3 e 0,7%, respectivamente, para as celas de 30 e 100 cm. O procedimento proposto foi seletivo para a determinação de carbaril, sem interferências de outros pesticidas carbamatos. O resíduo gerado foi tratado com persulfato de potássio e irradiação ultravioleta, com redução de 94% do carbono orgânico total, não sendo o resíduo degradado considerado tóxico, frente às bactérias Vibrio-fischeri. A determinação de sulfato foi baseada em medidas turbidimétricas com cela de fluxo de 1 cm, com resposta linear observada entre 20 - 200 mg L-1. Deriva de linha base não foi observada em função do fluxo pulsado gerado pelas microbombas solenoides. O limite de detecção e o coeficiente de variação (n = 20) foram estimados em 3 mg L-1 e 2,4%, respectivamente, com frequência de amostragem de 33 determinações por hora. Para aumentar a sensibilidade, uma cela de fluxo de 100 cm foi empregada e deriva de linha base foi evitada utilizando uma etapa de limpeza periódica com EDTA em meio alcalino. Resposta linear foi observada entre 7 - 16 mg L-1 com limite de detecção de 150 µg L-1 e coeficiente de variação de 3,0% (n = 20). A frequência de amostragem foi estimada em 25 determinações por hora. Resultados obtidos para amostras de águas naturais e de chuva foram concordantes a nível de confiança de 95% com o procedimento turbidimétrico em batelada. A determinação de cloro livre em águas naturais e de torneira foi baseada na reação com N,N-dietil-p-fenilenodiamina, com resposta linear entre 5 e 100 µg L-1 de hipoclorito e limite de detecção e coeficiente de variação estimados em 0,23 µg L-1 e 3,4%, respectivamente. A frequência de amostragem foi estimada em 58 determinações por hora. / Clean analytical procedures with high sensitivity for the determination of species of environmental interest (carbaryl, sulphate and chlorine) were developed. Flow systems with solenoid micropumps were coupled to long optical pathlength spectrophotometry or cloud point extraction procedures, aiming the concentration of species for determination without employing toxic solvents. Carbaryl determination in natural waters was based on a double cloud point extraction: a clean-up step for removal of interfering organic species and pre-concentration of the indophenol blue, formed in the reaction with the oxidized of p-aminophenol. Linear response was observed between 10 and 50 µg L-1, with apparent molar absortivity estimated as 4.6x105 L mol-1 cm-1. Detection limit was estimated as 7 mg L-1 and the coefficient of variation as 3.4% (n = 8). Recoveries between 91 and 99% were obtained for carbaryl spiked to natural waters. A simple and low cost flow cell with 30 cm optical path was constructed for spectrophotometric measurements. The cell shows desirable characteristics such as reduced attenuation of the radiation beam and internal volume (75 µL) comparable to conventional flow cells. The performance was evaluated by phosphate determination by the molibdenium blue method, with linear response between 0.05 and 0.8 mg L-1 of phosphate (r = 0.999). The increase in sensitivity (30.4 fold) in comparison to the obtained with a conventional 1 cm optical path flow cell agreed to theoretical value estimated by the Lambert-Beer law. The determination of carbaryl was also carried out in a flow system coupled to 30 and 100 cm optical path flow cells, also exploiting the formation of indophenol compound. Linear responses, detection limits and coefficients of variation were 50 - 750 and 5 - 200 µg L-1;4.0 and 1.7 µg L-1 and 2.3 and 0.7%, respectively, for 30 and 100 cm cells. The proposed procedure was selective for the determination of carbaryl, without interferences of other carbamate pesticides. The waste of the analytical procedure was treated with potassium persulphate and ultraviolet irradiation, with decrease of 94% of total organic carbon. The residue after treatment was not toxic for Vibrio-fischeri bacteria. Sulphate determination was based on turbidimetric measurements with 1-cm flow cell, with linear response between 20 and 200 mg L-1. Baseline drift was avoided in view of the pulsed flow related to the solenoid micropumps. The detection limit and the coefficient of variation were estimated as 3 mg L-11 and 2.4%, respectively, for a sampling rate of 33 determinations per hour. Aiming the increase in sensitivity, a 100 cm optical path flow cell was employed and baseline drift was avoided with a washing, step employing EDTA in alkaline medium. Linear response was observed between 7 - 16 mg L-1, with a detection limit of 150 µg L-1, coefficient of variation of 3.0% (n = 20) and sampling rate of 25 determinations per hour. Results obtained natural and rain for water samples agreed at 95% confidence level with the batch turbidimetric procedure. The determination of free chlorine in natural and tap waters was based on the reaction with N,N-diethyl-p-phenylenediamine, with linear response between 5 and 100 µg L-1, and detection limit and coefficient of variation estimated as 0.23 µg L-1 and 3.4%, respectively. Sampling rate was estimated as 58 determinations per hour.
52

Desenvolvimento de instrumentação e procedimentos analíticos automáticos empregando fotometria em fase sólida para determinação de zinco em produtos farmacêuticos e água / Combining multicommuted flow injection analysis and solid phase photometry for the determination of zinc in pharmaceutical preparation and water

Tuanne dos Reis Dias 25 August 2010 (has links)
Neste trabalho, é proposto o desenvolvimento de instrumentação e procedimentos analíticos automáticos empregando fotometria em fase sólida para determinação de zinco em produtos farmacêuticos e água. Para implementação do procedimento analítico, todo o sistema foi acoplado a um computador através de uma interface eletrônica. Um software escrito em linguagem QuickBASIC 4.5 permite que o computador efetue o controle da adição das soluções da amostra e do eluente e faça aquisição de dados. O sistema de detecção é constituído de uma cela de fluxo contendo, um LED e um fotodiodo. A geometria da cela de fluxo possibilitava variar o comprimento do caminho óptico. O procedimento para determinação do zinco foi baseado na retenção do analito na fase sólida (TAN-C18), previamente inserida na cela de fluxo, seguido de uma etapa de eluição. Com os parâmetros analíticos otimizados obteve-se resposta linear na faixa de 0,05 a 0,85 mg L-1 (R=0,995), limite detecção de 9,3 \'mü\'g L-1, coeficiente de variação de 1,4% (n=10) e frequência de amostragem de 36 det h-1. O módulo de análise foi aplicado em amostras de produtos farmacêuticos e a exatidão dos resultados foi averiguada comparando com os resultados obtidos por espectrometria de emissão óptica com plasma acoplado indutivamente ICP-OES. Aplicando-se tratamento estatístico apropriado, observou-se que não havia diferença significativa ao nível de confiança de 95 %. Estes resultados comprovam a viabilidade do emprego de fotômetro de LED em fotometria em fase sólida / In this work, it is propose the instrumentation and automatic analytic procedures development using solid phase spectrophotometry for determination of zinc in pharmaceutical preparations and water. For analytic procedure implementation, the whole system was coupled to a computer through an electronic interface. A written software in language QuickBASIC 4.5 allows the computer makes the sample solutions addition control and of eluent and do data acquisition. The detection system is constituted of a flow cell contend, a LED and a photodiode. The flow cell geometry enabled vary the length of the optical path. The procedure for zinc determination was going based in analyte retention in the solid phase (TAN-C18), previously inserted in the flow cell, followed by an elution stage. With the optimized analytic parameters it btained lineal answer in the band of 0,05 to 0,85 mg L-1 (R=0,995), limit detection of 9,3 \'mü\'g L-1, variation coefficient of 1,4% (n=10) and sampling throughput of 36 det h-1. The analysis module was going applied in pharmaceutical preparations samples and the exactness of the results was going ascertained comparing with the results obtained for inductively coupled plasma optic emission spectrometry of with ICP- its. Applying appropriated statistical treatment, it observed that there wasn\'t significant difference to the reliable level of 95 %. These results prove photometer job viability of LED in photometry in solid phase
53

Desenvolvimento de um equipamento portátil e de sistema de análises em fluxo empregando multicomutação. Determinação fotométrica de ferro em águas de rios / Development of a portable equipment and a flow analysis system employing multicommutation. Photometric determination of iron in river waters

Jeová Correia Miranda 20 July 2011 (has links)
O ferro é o elemento mais abundante na Terra e tem importante papel em ciclos biogeoquímicos Neste trabalho foi desenvolvido um procedimento analítico automático para a determinação fotométrica de ferro em águas de rios, empregando um fotômetro baseado em LED e mini-bombas solenoide para o gerenciamento de soluções. O procedimento proposto foi baseado na reação do ferro (III) com o tiocianato de potássio formando um complexo avermelhado com máximo de absorção em 470 nm. Para a determinação de ferro total foi incluída uma etapa de oxidação em linha, usando uma solução de persulfato (S2O82-) como oxidante. O módulo de análises foi constituído por quatro mini-bombas solenoide e uma válvula solenoide de três vias. Para a obtenção de sinais foi construído um fotômetro composto por uma cela de fluxo com caminho óptico de 50 mm, um LED azul (\'lâmbda\'=470 nm) e um fotodetector. Visando utilizar este equipamento portátil para medidas em campo, foram empregadas duas baterias de 6 V para alimentar os dispositivos ativos. Os ensaios em laboratório mostraram que as baterias permitem uma autonomia de mais de 50 horas de trabalho sem recarregá-las. O procedimento desenvolvido apresentou as seguintes características analíticas: resposta linear entre as concentrações de 0,25 e 4,0 mg L-1, segundo a equação Y = (0,0183 ± 0,003) + (0,15326 ± 0,002)X (r=0,9997); limite de detecção 0,013 mg L-1 Fe (III) estimado com 99,7 % de confiança; desvio padrão relativo estimado em 0,95 % (n=15) obtido com uma solução de concentração de 1,5 mg L-1 Fe (III); frequência de amostragem de 50 determinações por hora. Os resultados obtidos pelo procedimento proposto e pelo de referência não apresentaram diferenças significativas com nível de confiança de 95 % / Iron is the most abundant element on Earth and plays an important role in biogeochemical cycles. In this work, an automatic analytical procedure was developed for the photometric determination of iron in river waters, employing a LED-based photometer and solenoid mini-pumps for solution handling. The proposed procedure was based on the reaction between iron (III) and potassium thiocyanate, yielding a red complex with maximum absorption at 470 nm. For the determination of total iron, an in line oxidation step was included, employing a persulfate solution (S2O82-) as oxidant. The module was constructed with four solenoid mini-pumps and a three-way solenoid valve. For data acquisition a photometer was constructed with a 50 mm optical path flow cell, a blue LED (\'lâmbda\'= 470 nm) and a photodetector. Envisioning the use of this portable equipment in field, two 6-Volt batteries were employed to supply energy to the active devices. Laboratory tests showed that the batteries provide more than 50 hours of operation without recharging. The proposed procedure showed the following analytical features: linear response between 0.25 and 4.0 mg L-1, according to the equation Y = (0.0183 ± 0.003) + (0.15326 ± 0.002) X (r = 0.9997); detection limit of 0.013 mg L-1 Fe (III), estimated with 99.7 % of confidence; relative standard deviation estimated as 0.95% (n = 15), obtained with a 1.5 mg L-1 Fe (III) solution; sampling rate of 50 determinations per hour.The results obtained with the proposed and reference procedure did not show significative differences at a 95% confidence level
54

Desempenho de sistemas de extração e análises em fluxo explorando fluxo pulsado e leito fluidizado / Performance of extraction systems and flow analysis exploring pulsed flow and fluidized bed

Andrino, Jeane Maria Cunha Machado 28 April 2017 (has links)
O emprego de sistemas em fluxo com multi-impulsão são destaques quanto ao volume de efluentes gerados e a possibilidade de mecanização, operando em condições dinâmicas. A utilização de microbombas solenoide é potencial em processos de adsorção/dessorção de analitos, pois desempenham o fluxo pulsado, e quando operadas em conjunto com o estabelecimento da condição de leito fluidizado, contribuem para o aumento da eficiência de adsorção/dessorção. O objetivo geral deste trabalho foi desenvolver e avaliar sistemas de extração sólido-líquido e análises química em fluxo, explorando fluxos pulsados e o estabelecimento da condição de leito fluidizado, visando melhorar a eficiência de interação da amostra e reagente. Para tanto, foram desenvolvidos sistemas em fluxo com multi-impulsão associados ao uso de colunas de leito fluidizado. 1) Sistema para determinação da capacidade de adsorção de fósforo; determinação do fósforo remanescente (P-rem) em solos; 2) Sistema para determinação da capacidade de troca catiônica (CTC) de solos, avaliando a adsorção e a dessorção de analitos. Foi demonstrado que o fósforo e o cálcio contidos em solução são eficientemente adsorvidos/dessorvidos pelo solo, reduzindo significativamente os efeitos de aumento de pressão com o estabelecimento do leito fluidizado (fluidização pulsada) nas colunas contendo 50 mg de amostras de solo. A substituição do fluxo pulsado (microbomba solenoide) pelo fluxo contínuo (bomba peristáltica) limitou a interação sólido-líquido, pois estabeleceu caminhos preferenciais, desfavorecendo as condições de mistura. A utilização das microbombas solenoide em conjunto com a fluidização das amostras de solo, apresentou vantagens quanto à diminuição da quantidade de massa de solo requerida (entre 100 e 200 vezes), redução do consumo de reagentes e resíduos gerados (40 vezes), demonstrando o potencial do sistema em fluxo proposto por ser uma alternativa ambientalmente adequada. Os sistemas propostos são versáteis e facilmente adaptados para outros estudos de extração / Multi-pumping flow systems are highlights on the volume of effluents generated and mechanization, operating in dynamic conditions. Solenoid micro-pumps are potential in the analyte adsorption/desorption processes, because they play the pulsed flow and when operated in conjunction with the establishment of the fluidized bed condition, contribute to the increase of the adsorption/desorption efficiency. The objective of this work was to develop and evaluate solid-liquid extraction and flow analysis systems, exploring pulsed flows and establishing the fluidized bed condition in order to improve the solid-liquid interaction efficiency. It was developed multi-pumping flow systems associated with the establishment of the fluidized bed columns. 1) System for determination of phosphorus adsorption capacity; determination of the remaining phosphorus (P-rem) in soils; 2) System to determine the cation exchange capacity (CEC) of soils, evaluating the adsorption and desorption of analyte. It has been shown that the phosphorus and calcium contained in solution are efficiently adsorbed/desorbed by the soil, significantly reducing the effects of pressure increase with the establishment of the fluidized bed (pulsed fluidization) in the columns containing 50 mg of soil samples. The substitution of the pulsed flow (solenoid micro-pump) by the continuous flow (peristaltic pump) limited the solid-liquid interaction, since it established preferential pathways, undermining the mixing conditions. The use of the solenoid micro-pumps in conjunction with the fluidization of the soil samples presented advantages in terms of decreasing the amount of soil mass required (between 100 and 200-fold time), reducing the consumption of reagents, solutions and waste production (40-fold time), demonstrating the potential of this system to be an environmentally friendly alternative. The proposed systems are versatile and easily adapted to other extraction studies
55

Determinação fotométrica de sulfato e cloreto em coque de petróleo, molibdênio em plantas e zinco em águas empregando multicomutação com bomba de seringa / Photometric determination of sulfate and chloride in petroleum coke, molybdenum in plants and zinc in water employing multicommutation with syringe pump

Santos Junior, Felisberto Gonçalves 07 December 2016 (has links)
Nesta tese foram desenvolvidos procedimentos analíticos fotométricos automáticos para determinação simultânea de sulfato e cloreto em coque de petróleo, molibdênio em plantas sem etapa de pré-concentração com solvente orgânico e zinco em águas empregando microextração líquido-líquido. Em todos os procedimentos reportados nesta tese, o módulo de análise foi baseado no processo de multicomutação, utilizou-se bomba de seringa como propulsor de fluidos e válvulas solenoide de três vias como dispositivos de comutação para controlar as inserções das alíquotas da amostra e dos reagentes no percurso analítico. As detecções fotométricas foram realizadas empregando fotômetros de LEDs, construídos para este projeto, equipados com celas de fluxo com caminho óptico longo (50,0 mm para cloreto, sulfato e zinco, 200,0 mm para molibdênio). O fotômetro foi construído com LEDs de alto brilho como máximos de emissão em 472 nm para cloreto, sulfato e molibdênio e 525 nm para zinco. Os procedimentos para determinação simultânea de sulfato e cloreto apresentaram faixa linear entre 10-700 mg L-1; 0,25-10 mg L-1; limite de detecção de 5,3 mg L-1; 0,16 mg L-1; coeficiente de variação de 3,0%; 0,9 % (n=10), respectivamente, e frequência de amostragem de 75 determinações por hora para cada analito. O procedimento para determinação de molibdênio apresentou faixa linear entre 50 - 500 ?g L-1, limite de detecção 9,1 ?g L-1, coeficiente de variação 1,07% (n=10) e frequência de amostragem de 51 determinações por hora. O procedimento para zinco apresentou uma faixa linear entre 10-100 ?g L-1, limite de detecção 8,3 ?g L-1, coeficiente de variação 3,3% (n=10) e frequência de amostragem de 19 determinações por hora / In this thesis, automated photometric analytical procedures for simultaneous determination of sulfate and chloride in petroleum coke, molybdenum in plants without pre-concentration step and zinc in water using liquid-liquid microextraction were developed. All procedures reported in this thesis, employed flow analysis modules based on multicommuted process, syringe pump for fluid propulsion and solenoid three-way valves as commutation devices the insertion aliquots of sample and reagents solutions in the analytical path. Photometric detections were performed, using LEDs-photometers, built for this project, equipped with flow cells with long optical path (50.0 mm for chloride, sulfate and zinc, 200.0 mm for molybdenum) and the high intense radiation beam LEDs with maximum emission at 472 nm for chloride, sulfate and molybdenum and 525 nm for zinc. The procedures for simultaneous determination of sulfate and chloride showed linear response between 10 to 700 mg L-1; 0.25 to 10 mg L-1; detection limit of 5.3 mg L-1; 0.16 mg L-1; variation coefficient of 3.0%; 0.9% (n = 10), respectively, and sampling throughput of 75 determinations per hour for each analyte. The procedure for molybdenum presented a linear response between 50 to 500 ?g L-1, detection limit of 9.1 ?g L-1, variation coefficient of 1.07% (n = 10) and sampling throughput of 51 determinations per hour. The procedure for zinc showed linear response between 10 to 100 ?g L-1, detection limit of 8.3 ?g L-1, variation coefficient of 3.3% (n = 10) and sampling throughput of 19 determinations per hour
56

Determinação fotométrica de sulfato e cloreto em coque de petróleo, molibdênio em plantas e zinco em águas empregando multicomutação com bomba de seringa / Photometric determination of sulfate and chloride in petroleum coke, molybdenum in plants and zinc in water employing multicommutation with syringe pump

Felisberto Gonçalves Santos Junior 07 December 2016 (has links)
Nesta tese foram desenvolvidos procedimentos analíticos fotométricos automáticos para determinação simultânea de sulfato e cloreto em coque de petróleo, molibdênio em plantas sem etapa de pré-concentração com solvente orgânico e zinco em águas empregando microextração líquido-líquido. Em todos os procedimentos reportados nesta tese, o módulo de análise foi baseado no processo de multicomutação, utilizou-se bomba de seringa como propulsor de fluidos e válvulas solenoide de três vias como dispositivos de comutação para controlar as inserções das alíquotas da amostra e dos reagentes no percurso analítico. As detecções fotométricas foram realizadas empregando fotômetros de LEDs, construídos para este projeto, equipados com celas de fluxo com caminho óptico longo (50,0 mm para cloreto, sulfato e zinco, 200,0 mm para molibdênio). O fotômetro foi construído com LEDs de alto brilho como máximos de emissão em 472 nm para cloreto, sulfato e molibdênio e 525 nm para zinco. Os procedimentos para determinação simultânea de sulfato e cloreto apresentaram faixa linear entre 10-700 mg L-1; 0,25-10 mg L-1; limite de detecção de 5,3 mg L-1; 0,16 mg L-1; coeficiente de variação de 3,0%; 0,9 % (n=10), respectivamente, e frequência de amostragem de 75 determinações por hora para cada analito. O procedimento para determinação de molibdênio apresentou faixa linear entre 50 - 500 ?g L-1, limite de detecção 9,1 ?g L-1, coeficiente de variação 1,07% (n=10) e frequência de amostragem de 51 determinações por hora. O procedimento para zinco apresentou uma faixa linear entre 10-100 ?g L-1, limite de detecção 8,3 ?g L-1, coeficiente de variação 3,3% (n=10) e frequência de amostragem de 19 determinações por hora / In this thesis, automated photometric analytical procedures for simultaneous determination of sulfate and chloride in petroleum coke, molybdenum in plants without pre-concentration step and zinc in water using liquid-liquid microextraction were developed. All procedures reported in this thesis, employed flow analysis modules based on multicommuted process, syringe pump for fluid propulsion and solenoid three-way valves as commutation devices the insertion aliquots of sample and reagents solutions in the analytical path. Photometric detections were performed, using LEDs-photometers, built for this project, equipped with flow cells with long optical path (50.0 mm for chloride, sulfate and zinc, 200.0 mm for molybdenum) and the high intense radiation beam LEDs with maximum emission at 472 nm for chloride, sulfate and molybdenum and 525 nm for zinc. The procedures for simultaneous determination of sulfate and chloride showed linear response between 10 to 700 mg L-1; 0.25 to 10 mg L-1; detection limit of 5.3 mg L-1; 0.16 mg L-1; variation coefficient of 3.0%; 0.9% (n = 10), respectively, and sampling throughput of 75 determinations per hour for each analyte. The procedure for molybdenum presented a linear response between 50 to 500 ?g L-1, detection limit of 9.1 ?g L-1, variation coefficient of 1.07% (n = 10) and sampling throughput of 51 determinations per hour. The procedure for zinc showed linear response between 10 to 100 ?g L-1, detection limit of 8.3 ?g L-1, variation coefficient of 3.3% (n = 10) and sampling throughput of 19 determinations per hour
57

Desempenho de sistemas de extração e análises em fluxo explorando fluxo pulsado e leito fluidizado / Performance of extraction systems and flow analysis exploring pulsed flow and fluidized bed

Jeane Maria Cunha Machado Andrino 28 April 2017 (has links)
O emprego de sistemas em fluxo com multi-impulsão são destaques quanto ao volume de efluentes gerados e a possibilidade de mecanização, operando em condições dinâmicas. A utilização de microbombas solenoide é potencial em processos de adsorção/dessorção de analitos, pois desempenham o fluxo pulsado, e quando operadas em conjunto com o estabelecimento da condição de leito fluidizado, contribuem para o aumento da eficiência de adsorção/dessorção. O objetivo geral deste trabalho foi desenvolver e avaliar sistemas de extração sólido-líquido e análises química em fluxo, explorando fluxos pulsados e o estabelecimento da condição de leito fluidizado, visando melhorar a eficiência de interação da amostra e reagente. Para tanto, foram desenvolvidos sistemas em fluxo com multi-impulsão associados ao uso de colunas de leito fluidizado. 1) Sistema para determinação da capacidade de adsorção de fósforo; determinação do fósforo remanescente (P-rem) em solos; 2) Sistema para determinação da capacidade de troca catiônica (CTC) de solos, avaliando a adsorção e a dessorção de analitos. Foi demonstrado que o fósforo e o cálcio contidos em solução são eficientemente adsorvidos/dessorvidos pelo solo, reduzindo significativamente os efeitos de aumento de pressão com o estabelecimento do leito fluidizado (fluidização pulsada) nas colunas contendo 50 mg de amostras de solo. A substituição do fluxo pulsado (microbomba solenoide) pelo fluxo contínuo (bomba peristáltica) limitou a interação sólido-líquido, pois estabeleceu caminhos preferenciais, desfavorecendo as condições de mistura. A utilização das microbombas solenoide em conjunto com a fluidização das amostras de solo, apresentou vantagens quanto à diminuição da quantidade de massa de solo requerida (entre 100 e 200 vezes), redução do consumo de reagentes e resíduos gerados (40 vezes), demonstrando o potencial do sistema em fluxo proposto por ser uma alternativa ambientalmente adequada. Os sistemas propostos são versáteis e facilmente adaptados para outros estudos de extração / Multi-pumping flow systems are highlights on the volume of effluents generated and mechanization, operating in dynamic conditions. Solenoid micro-pumps are potential in the analyte adsorption/desorption processes, because they play the pulsed flow and when operated in conjunction with the establishment of the fluidized bed condition, contribute to the increase of the adsorption/desorption efficiency. The objective of this work was to develop and evaluate solid-liquid extraction and flow analysis systems, exploring pulsed flows and establishing the fluidized bed condition in order to improve the solid-liquid interaction efficiency. It was developed multi-pumping flow systems associated with the establishment of the fluidized bed columns. 1) System for determination of phosphorus adsorption capacity; determination of the remaining phosphorus (P-rem) in soils; 2) System to determine the cation exchange capacity (CEC) of soils, evaluating the adsorption and desorption of analyte. It has been shown that the phosphorus and calcium contained in solution are efficiently adsorbed/desorbed by the soil, significantly reducing the effects of pressure increase with the establishment of the fluidized bed (pulsed fluidization) in the columns containing 50 mg of soil samples. The substitution of the pulsed flow (solenoid micro-pump) by the continuous flow (peristaltic pump) limited the solid-liquid interaction, since it established preferential pathways, undermining the mixing conditions. The use of the solenoid micro-pumps in conjunction with the fluidization of the soil samples presented advantages in terms of decreasing the amount of soil mass required (between 100 and 200-fold time), reducing the consumption of reagents, solutions and waste production (40-fold time), demonstrating the potential of this system to be an environmentally friendly alternative. The proposed systems are versatile and easily adapted to other extraction studies
58

Caracterização estrutural do complexo Cu(II) / DPKBH e desenvolvimento/aplicação de método espectrofotométrico em fluxo, empregando multicomutação e amostragem binária, para determinação de Cu(II), Fe(II) e Fe(III) / Structural characterization of the Cu (II) / DPKBH complex and the development/application of spectrophotometric flow method, using multicomputing and binary sampling, for Cu (II), Fe (II) and Fe (III)

Prada, Silvio Miranda 22 February 2001 (has links)
Desenvolveu-se um método espectrofotométrico para determinação de íons Cu(II), Fe(II) e Fe(III) com o reagente cromogênico di-2-piridil cetona benzoilhidrazona (DPKBH), em condições estacionárias e em fluxo. Fez-se a caracterização estrutural e estequiométrica do complexo de Cu(II) com DPKBH usando-se técnicas espectroscópicas de infravermelho e massas, além de análise térmica e elementar. Estudou-se, ainda, a estequiometria dos complexos de Fe(II) e Fe(III) com DPKBH utilizando espectrometria de massas com ionização por electrospray. Desenvolveu-se, preliminarmente, um método espectrofotométrico para a determinação de íons Cu(II) com DPKBH e aplicou-se em amostras de aguardente. Posteriormente, adaptou-se para análise por injeção em fluxo, utilizando-se injetor comutador manual. Em seguida, desenvolveu-se em condições estacionárias um método espectrofotométrico para determinação de Fe(II) e Fe(III) e Cu(II) em uma mesma amostra, com o uso de agentes mascarantes. Fez-se também a adaptação do método para análise em fluxo empregando multicomutação e amostragem binária. Finalmente, determinou-se a concentração de íons Cu(II), Fe(II) e Fe(III) em amostras sintéticas e Cu(II) e ferro total em amostras de sedimento coletadas no reservatório de Guarapiranga. Os resultados obtidos foram comparados com o método de referência de ICP-OES, apresentando concordância para um nível de confiança de 95% da média. / A spectrophotometric method was developed to the determination of Cu(II), Fe(II) and Fe(III) with the chromogenic reagent di-2pyridyl ketone benzoylhydrazone (DPKBH) in stationary conditions as a flow injection process. The structural characterization and the stoichiometry of Cu(II)/DPKBH complex were achieved using infrared spectrometry, mass spectrometry, thermal and elementar analysis. Toe stoichiometry of the Fe(II) and Fe(III) complexes with DPKBH was studied by electrospray ionization mass spectrometry. The spectrophotometric method for the determination of Cu(II) with DPKBH was developed in stationary conditions and, after this, it was adapted to flow injection analysis, using a manual commutator. Subsequently, a spectrophotometric method was developed to determine Fe(II), Fe(III) and Cu(II) in the same sample, in stationary conditions, using masking reagents. This method was also adapted to flow injection analysis, using multicommutation and binary sampling. Finally, Cu(II), Fe(II) and Fe(III) were determined in sediments from Guarapiranga reservoir. The obtained results were compared with the ICP-OES standard methods, showing a good agreement into a 95% confidence level (t-test).
59

Caracterização estrutural do complexo Cu(II) / DPKBH e desenvolvimento/aplicação de método espectrofotométrico em fluxo, empregando multicomutação e amostragem binária, para determinação de Cu(II), Fe(II) e Fe(III) / Structural characterization of the Cu (II) / DPKBH complex and the development/application of spectrophotometric flow method, using multicomputing and binary sampling, for Cu (II), Fe (II) and Fe (III)

Silvio Miranda Prada 22 February 2001 (has links)
Desenvolveu-se um método espectrofotométrico para determinação de íons Cu(II), Fe(II) e Fe(III) com o reagente cromogênico di-2-piridil cetona benzoilhidrazona (DPKBH), em condições estacionárias e em fluxo. Fez-se a caracterização estrutural e estequiométrica do complexo de Cu(II) com DPKBH usando-se técnicas espectroscópicas de infravermelho e massas, além de análise térmica e elementar. Estudou-se, ainda, a estequiometria dos complexos de Fe(II) e Fe(III) com DPKBH utilizando espectrometria de massas com ionização por electrospray. Desenvolveu-se, preliminarmente, um método espectrofotométrico para a determinação de íons Cu(II) com DPKBH e aplicou-se em amostras de aguardente. Posteriormente, adaptou-se para análise por injeção em fluxo, utilizando-se injetor comutador manual. Em seguida, desenvolveu-se em condições estacionárias um método espectrofotométrico para determinação de Fe(II) e Fe(III) e Cu(II) em uma mesma amostra, com o uso de agentes mascarantes. Fez-se também a adaptação do método para análise em fluxo empregando multicomutação e amostragem binária. Finalmente, determinou-se a concentração de íons Cu(II), Fe(II) e Fe(III) em amostras sintéticas e Cu(II) e ferro total em amostras de sedimento coletadas no reservatório de Guarapiranga. Os resultados obtidos foram comparados com o método de referência de ICP-OES, apresentando concordância para um nível de confiança de 95% da média. / A spectrophotometric method was developed to the determination of Cu(II), Fe(II) and Fe(III) with the chromogenic reagent di-2pyridyl ketone benzoylhydrazone (DPKBH) in stationary conditions as a flow injection process. The structural characterization and the stoichiometry of Cu(II)/DPKBH complex were achieved using infrared spectrometry, mass spectrometry, thermal and elementar analysis. Toe stoichiometry of the Fe(II) and Fe(III) complexes with DPKBH was studied by electrospray ionization mass spectrometry. The spectrophotometric method for the determination of Cu(II) with DPKBH was developed in stationary conditions and, after this, it was adapted to flow injection analysis, using a manual commutator. Subsequently, a spectrophotometric method was developed to determine Fe(II), Fe(III) and Cu(II) in the same sample, in stationary conditions, using masking reagents. This method was also adapted to flow injection analysis, using multicommutation and binary sampling. Finally, Cu(II), Fe(II) and Fe(III) were determined in sediments from Guarapiranga reservoir. The obtained results were compared with the ICP-OES standard methods, showing a good agreement into a 95% confidence level (t-test).

Page generated in 0.0357 seconds