• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 66
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 66
  • 44
  • 24
  • 20
  • 12
  • 12
  • 11
  • 10
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Influência da ciclagem com cargas dinâmicas na microinfiltração de coroas metalocerâmicas cimentadas com três tipos de cimento

Paulo Henrique Orlato Rossetti 29 April 2003 (has links)
O propósito deste estudo foi avaliar "in vitro" as mensurações e possíveis correlações entre discrepância de assentamento, abertura marginal e padrão de microinfiltração, em coroais metalocerâmicas cimentadas com três tipos de agentes cimentantes: fosfato, ionômero e cimento resinoso dual. Trinta dentes pré-molares humanos extraídos foram preparados para coroas metalocerâmicas e as fundições foram realizadas com liga de Ni-Cr. As amostras foram divididas em três grupos, de acordo com o agente cimentante e a cimentação foi realizada sob uma carga de 5Kg por 10 minutos e as amostras armazenadas em água por 24hs. A discrepância de assentamento foi registrada antes e após a cimentação em um microscópio óptico com precisão de 0,001micrometro. Metade dos espécimes dentro de cada grupo foi submetida ao teste de fadiga cíclica (50.000 ciclos, 2,5Hz). As coroas foram seccionadas longitudinalmente no sentido vestíbulo-lingual e na interface coroadente-cimento foi aplicado um corante (rodamina B) por 15 segundos. A penetração do corante foi quantificada ao longo da interface sob um microscópio óptico (80 vezes de aumento) e, posteriormente, as amostras foram preparadas para microscopia eletrônica de varredura a fim de quantificar a abertura marginal e a qualidade da interface. Os resultados de discrepância de assentamento foram maiores para o cimento fosfato de zinco, seguido do ionômero de vidro e resinoso, sem diferença estatística. Foram encontradas diferenças estatisticamente significantes entre a discrepância de assentamento e a abertura marginal para os três cimentos. Os resultados de infiltração foram maiores para o cimento fosfato de zinco, seguido do ionômero de vidro e resinoso, com diferenças estatisticamente significantes. A ciclagem mecânica aumentou a infiltração marginal para o cimento fosfato de zinco, com diferença estatisticamente significativa em relação ao cimento ionomérico e resinoso. A análise ao microscópio eletrônico de varredura detectou melhor qualidade de união na interface dente-cimento para o sistema resinoso, seguido pelo cimento ionomérico e resinoso. / The purpose of this study was to verify "in vitro" measures and possible correlations between seating discrepancy, marginal opening and microleakage pattern under total metallic crowns cemented with three types of luting agents: phosphate, glass-ionomer and resin dual cement. Thrirty extracted human premolars teeth were prepared for total metalloceramic crowns and castings obtained with a Ni-Cr alloy. Samples were ramdomly assigned for three groups in according to each luting agent: zinc phosphate (S.S.White), resin-modified glass-ionomer (Vitremer-3M) or a dual resin cement (Enforce-Dentsply). Cementation was done under a 49N load for 10 minutes and water stored for 24hs. Vertical discrepancy was registered before and after cementation in an optical microscopy with the accuracy of 0,001mm). Half of the specimens within each group was submitted to a cyclic loading test (50000 cycles, 2,5Hz). Crowns were longitudinally seccionated in a bucco- lingual plane at the tooth-cement-crown interface and dye solution (rodhamine B) was apllied to tooth-cement- interface for 15 seconds The linear stain penetration along tooth-cement was quantified. under a light microscope (80X magnification) and then samples were prepared for scanning electronic microscope in order to quantify marginal opening and the quality of interface. The results for seating discrepancy were higher for zinc phosphate, followed by glass-ionomer and resin cement, with no statistical difference. Statistically significant differences were found between seating discrepancy and marginal opening for the three cements. Microleakage results were higher for zinc phosphate, followed by glass-ionomer and resin cement, with statiscally significant differences. Fatigue loading rinsed marginal leakage for zinc pohsphate, with statiscally significant difference in respect to glassionomer and resin cement. Scanning electron microscope analysis showed better marginal quality at the tooth-cement-restoration interface for resinous cement,followed by glass-ionomer and zinc phosphate cement.
42

Resistência de união e da microinfiltração marginal em restaurações fotopolimerizadas com LED e luz halógena associadas a três modos de aplicação de um sistema adesivo universal: estudo in vitro / Bond strength and marginal microleakage restorations cured with LED and halogen dental curing light associated to three modes of application of a universal adhesive system: in vitro study

Ricardi, Felipe de Brum 02 March 2017 (has links)
Submitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2018-04-13T17:05:10Z No. of bitstreams: 2 Felipe_Ricardi2017.pdf: 1032662 bytes, checksum: 6aaca7ee5122dd1349c2efde06964976 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-04-13T17:05:10Z (GMT). No. of bitstreams: 2 Felipe_Ricardi2017.pdf: 1032662 bytes, checksum: 6aaca7ee5122dd1349c2efde06964976 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-03-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The objective was to evaluate the bond strength and marginal microleakage in composite resin restorations, using Universal Single Bond adhesive system associated with Ultralux (halogen) and Bluephase (LED) photoactivators. For bond strength, eighty healthy human third molars were divided: Halogen (n = 40); LED (n = 40), subdivided according to the technique of application of the adhesive system: self-etch – enamel; etch-and-rinse – enamel, self-etch – dentin; etch-and-rinse – dentin. The teeth were submitted to the Tensile Bond Strength test and the fracture pattern was observed under an optical microscope - 40X magnification, analyzed by the ANOVA, Tukey and Fisher tests (5%). For the marginal microleakage assay, 120 class II cavities were prepared in sixty healthy, randomly divided third human molars: Halogen (n = 30); LED (n = 30) and subdivided according to the application technique of the adhesive system: self-etch; selective-etch; etch-and-rinse. The teeth were thermocycled 2000 times (± 5 / 55ºC), stained in 5% basic fuchsin and sectioned for qualitative and quantitative evaluations, analyzed by the Kruskall-Wallis and Dunn tests (5%). For bond strength in enamel and dentin, the adhesive application with prior acid etching was better than the etch-and-rinse (p <0.0001), regardless of the type of photoactivator used (p <0.05). The self-etch showed the lowest values of microleakage, (p <0.0001). The self-etch, obtained the best results in relation to the other techniques of application of the adhesive system in both tests, regardless of the type of photoactivating apparatus. / O objetivo foi avaliar a resistência de união e microinfiltração marginal em restaurações de resina composta, utilizando sistema adesivo Single Bond Universal associado com fotoativadores Ultralux (halógeno) e Bluephase (LED). Para resistência de união, oitenta terceiros molares humanos hígidos foram divididos: Halógena (n=40); LED (n=40), sendo subdivididos de acordo com a técnica de aplicação do sistema adesivo: condicionamento total-esmalte; autocondicionante-esmalte; condicionamento total-dentina; autocondicionante-dentina. Os dentes foram submetidos ao teste de microtração e o padrão de fratura foi observado em microscópio ótico – 40X de aumento, analisadas pelos testes ANOVA, Tukey e Fisher (5%). Para o ensaio de microinfiltração marginal, 120 cavidades classe II foram preparadas em sessenta terceiros molares humanos hígidos, aleatoriamente divididos: Halógena (n=30); LED (n=30) e subdivididos de acordo com a técnica de aplicação do sistema adesivo: condicionamento total; condicionamento seletivo; autocondicionante. Os dentes foram termociclados 2000 vezes (±5/55ºC), corados em fucsina básica 5% e seccionados para avaliações qualitativa e quantitativa, analisados pelos testes Kruskall-Wallis e Dunn (5%). Para resistência de união em esmalte e dentina, a aplicação do adesivo com condicionamento ácido prévio, foi melhor que o autocondicionante (p<0.0001), independentemente do tipo de fotoativador utilizado (p<0.05). O condicionamento total mostrou os menores valores de microinfiltração, (p<0.0001). O condicionamento total, obteve os melhores resultados em relação às outras técnicas de aplicação do sistema adesivo em ambos os testes, independentemente do tipo de aparelho fotoativador.
43

Influência do tipo de sistema de infra-estrutura na adaptação e microinfiltração de coroas totais cerâmicas / Influence of the type of framework system in the adaptation and microleakage of all-ceramic crowns

Maria Tereza Moura de Oliveira Cavalcanti 04 April 2008 (has links)
Os objetivos deste trabalho foram: a quantificação da microinfiltração e desadaptação antes e após cimentação de coroas totais cerâmicas, com quatro tipos de sistemas de infra-estrutura e a correlação entre desadaptação e microinfiltração. Após aprovação pelo Comitê de Ética da FOUSP, 40 terceiros molares humanos receberam coroais totais cerâmicas, sendo: 2 cerâmicas infiltradas por vidro (In-Ceram alumina Slip-Cast (S) e o bIoco In-Ceram Alumina CA-12 (CA)) e 2 cerâmicas de alumina policristalina (Procera/Nobel Biocare (P) e o bloco In-Ceram Al-20, CEREC In-Lab (CE)), (n=10). O espaço entre coroa e dente foi medido antes e depois da cimentação das coroas. Foram submetidos à ciclagem mecânica (100.000 ciclos, 8 Kgf, 4 Hz), térmica (700 ciclos, 5/55ºC por minuto), submersos em azul de metileno 0,5% por 4 horas e seccionados nos sentidos mésio/distal e vestíbulo/lingual. As imagens foram obtidas em estereomicroscópio (20X) e os dados de desadaptação foram submetidos à ANOVA (e Tukey). Os escores da microinfiltração foram submetidos à análise da concordância dos avaliadores e Kruskal-Wallis. Não houve diferenças significantes entre os sistemas cerâmicos (S= 38, P= 49, CA= 48 e CE= 39?m). O fator \"região\" da linha de cimentação apresentou diferenças estatísticas. A desadaptação foi maior na parede pulpar (60 ?m), seguida dos ângulos axio-pulpar e gengivo-axial (57 e 48 ?m, respectivamente). As paredes axiais e margens foram os locais de menor desadaptação (27 e 26 ?m, respectivamente). Houve diferença estatística entre as duas técnicas de medida, antes e após a cimentação (46 e 41?m, respectivamente). Houve diferença estatisticamente significante entre os quatro tipos de sistemas cerâmicos avaliados quanto à microinfiltração, onde S e CE apresentaram maiores níveis de infiltração, seguidos de P e CA. Não houve correlação entre microinfiltração e desadaptação. Concluiu-se que os quatro sistemas cerâmicos avaliados produziram coroas totais com linha de cimentação dentro dos limites clinicamente aceitáveis. / The objectives of this study were to quantify the microleakage and the loss of marginal adaptation before and after cementation of all-ceramic crowns, with four types of infrastructure systems, and to compare these parameters. After approval by the Committee on Ethics in Research of Dental School of University of São Paulo, 40 human third molars received all-ceramic crowns, 2 glass-infiltrated ceramics (In-Ceram alumina Slip-Cast (S) and the block In-Ceram Alumina CA-12 (CA) ) and 2 polycrystalline alumina ceramics (Procera / Nobel Biocare (P) and the block Ceram In-Al-20, CEREC In-Lab (EC) (n = 10). The gap between ceramic dental prosthesis and tooth was measured before and after cementation of the crowns. They were subjected to mechanical load cycling (100,000 cycles, 8 Kgf, 4 Hz), thermocycling (700 cycles, 5 / 55 ° C per minute), immersed in 0.5% methylene blue dye for 4 hours and then sectioned in the mesial / distal and buccal / lingual aspects. The images were obtained in stereomicroscope (20X) and the marginal fit data were evaluated by ANOVA (and Tukey test). The microleakage values were analyzed by the correlation analysis of examiners and the Kruskal-Wallis test. There were no significant differences between the ceramic systems (S = 38, P = 49, CA = 50 and CE = 39 ? m). The factor \"region\" of the cementation line has presented statistical differences. The loss of adaptation was higher on the pulpal wall (61 ? m), followed by gingival-axial (49 ? m) and axial-pulpal (58 ? m) angles. The axial walls and margins were the sites of the smallest displacement (27 and 26 ?m, respectively). There was statistical difference between the two techniques of measurement, before and after cementation (47 and 41 ?m, respectively). Statistically significant difference among the four types of ceramic systems was detected for microleakage, whereas S and CE showed higher levels of infiltration, followed by P and CA. However, no correlation was found between microleakage and loss of marginal adaptation. It was concluded that the four systems produced all-ceramic crowns with the line of cementation within clinically acceptable limits.
44

Avaliação "in vitro" da microinfiltração marginal em restaurações classe II, confeccionadas com um cimento de ionômero de vidro modificado por resina, uma resina composta "semicondensável" e uma resina composta "condensável". / In vitro evaluation of marginal microleakage in class II restorations, made with a glass ionomer cement modified through resin Vitremer, "semicondensable" composite resin Ariston pHc and "condensable" composite resin P-60.

Maria Fernanda Borro Bijella 25 August 2000 (has links)
Avaliou-se in vitro a microinfiltração marginal em restaurações classe II, realizadas com o cimento de ionômero de vidro modificado por resina Vitremer, a resina composta "semicondensável" Ariston pHc e a resina composta "condensável" P-60, com o propósito de verificar a influência da ciclagem térmica para estes materiais, como também dois métodos de análise da penetração do corante. Para tanto, 60 pré-molares, receberam cavidades classe II proximais, com a parede cervical localizada 1mm abaixo da junção cemento-esmalte. Os espécimes foram divididos em 3 grupos de 20 dentes cada. O grupo I foi restaurado com Vitremer, o grupo II com Ariston pHc e o grupo III com P-60. Após a restauração, os espécimes foram acondicionados em recipientes plásticos com água deionizada por 24 horas a 37°C. Decorrido esse período as restaurações receberam acabamento e polimento. Enquanto metade de cada grupo sofreu processo de termociclagem com 500 ciclos nas temperaturas de 5°C e 55°C, em banhos de 15 segundos cada, a outra metade permaneceu acondicionada em recipientes plásticos com água deionizada a 37°C. Após o período de teste, todos os espécimes foram imersos em solução de fucsina básica a 0,5% por 24 horas a 37°C, sendo em seguida lavados abundantemente em água corrente durante 24 horas. Para análise da microinfiltração os dentes foram incluídos em resina plástica autopolimerizável e seccionados no sentido mesio-distal, sofrendo uma média de quatro cortes cada dente. Para cada corte, foram obtidas duas imagens para serem analisadas através de um software denominado Imagetools. Os resultados foram avaliados através do teste estatístico de Análise de Variância a dois critérios (2-way ANOVA) e o teste de Tukey para comparações múltiplas entre os materiais, em nível de significância de 5%. Os resultados demonstraram que todos os grupos testados apresentaram microinfiltração marginal, sendo que o cimento de ionômero de vidro modificado por resina Vitremer apresentou resultados sempre melhores, vindo a seguir a resina composta "condensável" P-60 e por último a resina composta "semicondensável" Ariston pHc. Não houve diferença estatisticamente significante no uso ou não da termociclagem para estes materiais. Quando avaliou-se os métodos de análise de penetração do corante, o método através da máxima infiltração parece ser o melhor para detectar a extensão da microinfiltração. / It was the purpose of this work to assess in vitro marginal microleakage in class II restorations, made with a glass ionomer cement modified through resin Vitremer, "semicondensable" composite resin Ariston pHc and "condensable" composite resin P-60, pretending to verify the influence of thermocycling upon these materials, as well as of the performance of two methods for dye penetration analysis. Thus, 60 premolars received proximal class II cavities, with cervical wall situated above cement/enamel junction. The specimens were divided in three groups with 20 teeth each. Group I was restored with Vitremer, Group II with Ariston pHc and Group III with P-60. Following restoration, specimens were stored in plastic containers with deionized water for 24 hours under 37ºC. After this time period restorations were finished and polished. While half the group suffered a thermocycling process with 500 cycles under temperatures of 5ºC and 55ºC, in baths of 15 seconds each, the other half remained stored in plastic containers with deionized water under 37ºC. After testing period, all specimens have been immersed into a 0.5% basic fuchsin solution for 24 hours under 37ºC, being next thoroughly washed in running water for 24 hours. For microleakage analysis, teeth were embedded in autopolimerizing plastic resin and sectioned in a mesiodistal sense, each tooth suffering a mean of four sections. For each section two images were obtained for the analysis through a software called Imagetools. Results have been examined through a Variance Analysis statistical test through two criteria (2-way ANOVA) and Tukey test for multiple comparisons between materials, at a 5% significance level. Results showed that all tested groups presented marginal microleakage, glass ionomer cement modified with resin Vitremer always presenting the best results, followed by "condensable" composite resin P-60 and coming last "semicondensable" composite resin Ariston pHc. There was no statiscally significant difference between the use and non-use of thermocycling for these materials. When methods for dye penetration analyses were assessed the method of maximum leakage seems to be the best one for detecting microleakage extension.
45

Avaliação In vitro da microinfiltração marginal de restaurações de amálgama em cavidades classe II associadas à adesivo dentinário, cimento de ionômero de vidro e verniz cavitário

Adriano Tomio Hoshi 11 December 2000 (has links)
Em Odontopediatria, o amálgama dentário ainda é muito utilizado, uma vez que é altamente resistente, insolúvel aos fluídos bucais, de baixo custo e de fácil manipulação, não sendo um material de alta sensibilidade técnica. A sua grande desvantagem é a falta de adesão à estrutura dentária, associada à microinfiltração marginal. Entretanto, estes problemas tendem a ser reduzidos através de sua associação aos adesivos dentinários ou aos cimentos de ionômero de vidro (CIV), quando comparados ao verniz cavitário. Este trabalho avaliou, in vitro, a microinfiltração marginal de restaurações de amálgama associadas ao verniz cavitário Copalite - Cooley & Cooley (GI - CP), ao adesivo dentinário OptiBond Solo - Kerr (GII - OS) e ao CIV Vitremer - 3M Dental Products (GIII - VT). Foram utilizados 45 pré-molares hígidos e extraídos, que receberam cavidades independentes classe II nas faces mesial e distal, envolvendo as cristas marginais. Todas as cavidades foram restauradas com a liga Dispersalloy - Dentsply, sendo que, posteriormente, os dentes sofreram termociclagem nas temperaturas de 5oC e 55oC por 500 ciclos, com banhos de 15 segundos em água deionizada. Os dentes foram então armazenados em solução de fucsina básica a 0,5% por 24 horas, a 37oC. Após este período, foram lavados em água corrente por 24 horas e seccionados no sentido mésio-distal. As fatias obtidas foram avaliadas em um microscópio óptico com aumento de 150 vezes (Mitutoyo TM-505) e no software Sigma Scan, utilizando linha única e linhas segmentadas. A análise dos dados obtidos permitiu constatar que nenhum dos materiais foi capaz de eliminar a microinfiltração marginal, sendo que o GI - CP apresentou valores maiores e estatisticamente significantes em relação aos demais grupos em todos os métodosde avaliação. Os menores valores foram obtidos pelo GIII - VT, porém sem diferença estatisticamente significante quando comparado ao GII - OS, exceto pela avaliação no Sigma Scan em linha única, para um valor de p<0,05. Os três métodos de avaliação de medidas lineares empregados mostraram ter uma forte correlação positiva, apesar de apresentarem resultados estatisticamente diferentes entre si em pelo menos um dos grupos de estudo. / Dental amalgam is still largely utilized in pediatric dentistry, since it is highly resistant, insoluble in buccal fluids, easy to work, has a low cost and is not a highly and technically sensitive material. Its great disadvantage is the lack of adhesion to dental structure, associated with marginal microleakage. Nevertheless, these problems tend to be reduced through its association with dentinal adhesives or glass ionomer cements (GIC), when compared with cavity varnish. This in vitro study evaluated the marginal microleakage in amalgam restorations associated with Copalite cavity varnish - Cooley & Cooley (GI - CP), OptiBond Solo dentinal adhesive - Kerr (GII - OS) and GIC Vitremer - 3M Dental Products (GIII - VT). Fortyfive sound and extracted premolars which received independent class II cavities in the mesial and distal surfaces, involving the marginal ridges were utilized. All the cavities were restored with Dispersalloy - Dentsply and the teeth were then thermocycled at the temperatures of 5oC and 55 oC for 500 cycles in deionized water with a 15 seconds dwell time. The teeth were then immersed in 0,5% basic fuchsin solution for 24 hours, at 37oC. Following this period, they were rinsed in tap water for 24 hours and mesio-distally sectioned. The slices obtained were assessed in a light microscope at x150 (Mitutoyo TM-505) and with the Sigma Scan software by utilizing single and segmented lines. The data analysis allowed to establish that none of thematerials was capable of eliminating marginal microleakage, being GI - CP the one to present the greatest and statistically significant values in relation to the remaining groups, in all evaluation methods. The smallest values were obtained by GIII - VT, however, without statistically significant difference when compared with GII - OS, except by Sigma Scan evaluation in a single line for a p<0,05. The three methods of linear measurement evaluation showed a strong and positive correlation, although they presented statistically different results among them in at least one of the study groups.
46

Avaliação em microscopia óptica e eletrônica de varredura da influência do ácido cítrico como agente condicionante sobre o selamento marginal em cavidades classe II: um estudo “in vitro”

Menezes, Elysangela Borges de 24 May 2013 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-04-11T18:03:07Z No. of bitstreams: 1 elysangelaborgesdemenezes.pdf: 1092752 bytes, checksum: 64cc3916e226aa77b6029e88791a97e3 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-04-24T03:35:18Z (GMT) No. of bitstreams: 1 elysangelaborgesdemenezes.pdf: 1092752 bytes, checksum: 64cc3916e226aa77b6029e88791a97e3 (MD5) / Made available in DSpace on 2016-04-24T03:35:18Z (GMT). No. of bitstreams: 1 elysangelaborgesdemenezes.pdf: 1092752 bytes, checksum: 64cc3916e226aa77b6029e88791a97e3 (MD5) Previous issue date: 2013-05-24 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar a influência dos géis de ácido cítrico e ácido fosfórico sobre o selamento marginal em cavidades classe II restauradas com resina composta nanoparticulada. Trinta e cinco molares humanos hígidos tiveram suas coroas preparadas com cavidades tipo slot vertical sendo o término gengival abaixo da junção esmalte-cemento. Os dentes foram divididos aleatoriamente em sete grupos de acordo com o agente condicionante e tempo de aplicação a ser empregado (n=10): Grupo I: Ácido Cítrico 25% por 30 segundos; Grupo II: Ácido Cítrico 35% por 30 segundos; Grupo III: Ácido Cítrico 10% por 15 segundos; Grupo IV: Ácido Cítrico 10% por 30 segundos; Grupo V – Ácido Fosfórico 35% por 15 segundos, Grupo VI: Ácido Cítrico 35% por 15 segundos, Grupo VII: Ácido Cítrico 25% por 15 segundos. As cavidades foram restauradas com resina composta nanoparticulada Filtek Z350, sendo a mesma inserida através da técnica incremental. O sistema adesivo utilizado foi Scotchbond Multi Purpose (3M). As amostras foram submetidas à termociclagem de 5000 ciclos. Posteriormente cada grupo foi imerso em solução de nitrato de prata amoniacal por 24 horas. Em seguida, os dentes foram seccionados no sentido mesio-distal e a microinfiltração marginal foi avaliada através do Microscópio Óptico (MO) pelo método de escores. O Microscópio Eletrônico de Varredura (MEV) foi utilizado para observação qualitativa da presença ou não de fendas na restauração. Para esta análise foi selecionado o pior e o melhor resultado de cada grupo. Os resultados foram submetidos a análise estatística pelo teste não-paramétrico de Kruskal Wallis, e análise de Variância de Mann-Whitney (p=0,05). O estudo concluiu que a concentração e tempo de aplicação do ácido cítrico têm efeito estatísticamente significante na microinfiltração marginal. O ácido cítrico provou ser um possível substituto do ácido fosfórico no condicionamento ácido dentinário. / The aim of this study was to evaluate the influence of the gels of citric acid and phosphoric acid on microleakage in class II cavities restored with composite nanoparticle. Thirty five human molars were used, in which were made cavities as vertical slots with gingival ending below the enamel-cementum junction. The teeth were randomly divided into seven groups according to the conditioning agent and application time to be used (n=10): Group I: 25% citric acid for 30 seconds; Group II: 35% citric acid for 30 seconds; Group III 10% citric acid for 15 seconds and Group IV: 10% citric acid for 30 seconds and Group V - 35% phosphoric acid for 15 seconds, Group VI: 35% citric acid for 15 seconds, Group VII: 25% citric for 15 seconds. The cavities were restored with Filtek Z350 composite nanoparticles; witch was introduced in the cavity by an incremental technique. The adhesive system was Scotchbond Multi Purpose (3M). The samples were subjected to thermocycling for 5000 cycles. Afterwards each group was immersed in a solution of ammoniacal silver nitrate for 24 hours. Then, the teeth were sectioned mesio-distal and microleakage was evaluated by the Optical Microscope (OM) using the scores. The Scanning Electron Microscope (SEM) was used for qualitative observation of the presence or absence of cracks in the restoration. For this analysis we selected the worst and the best result for each group. The results were submitted to a statistic analysis using the Kruskal Wallis Test and with the Mann-Whitney (p=0,05). The study concluded that the concentration and time of application of citric acid have statistically significant effect on microleakage. Citric acid proved to be a possible replacement of phosphoric acid etching on dentin.
47

Avaliação “in vitro” da infiltração coronária de materiais restauradores temporários em cavidades complexas classe II-mod submetidos à ação de termociclagem e forças mecânicas

Silva, Mauro Henrique Chagas e 28 June 2013 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-04-11T12:06:51Z No. of bitstreams: 1 maurohenriquechagasesilva.pdf: 2211214 bytes, checksum: 7e35d9cec8fd1ce921b9e22dec1b0d8f (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-04-24T03:38:38Z (GMT) No. of bitstreams: 1 maurohenriquechagasesilva.pdf: 2211214 bytes, checksum: 7e35d9cec8fd1ce921b9e22dec1b0d8f (MD5) / Made available in DSpace on 2016-04-24T03:38:38Z (GMT). No. of bitstreams: 1 maurohenriquechagasesilva.pdf: 2211214 bytes, checksum: 7e35d9cec8fd1ce921b9e22dec1b0d8f (MD5) Previous issue date: 2013-06-28 / O objetivo deste estudo foi avaliar “in vitro”, a microinfiltração coronária em cavidades complexas classe II-MOD seladas com materiais restauradores temporários, submetidos à ação de termociclagem e forças mecânicas. Cavidades MOD foram preparadas em 60 pré-molares superiores extraídos de humanos que foram divididos em três grupos de acordo com o material restaurador temporário (MRT) utilizado: G1- IRM; G2- Coltosol; G3- Fill Magic Tempo. Três dentes serviram como controle negativo e não tiveram cavidades preparadas. Antes do selamento das cavidades com o MRT, uma esponja de colágeno foi deixada dentro da câmara pulpar para avaliação binária da penetração do corante. Dez dentes de cada grupo foram submetidos à ação da termociclagem e forças mecânicas oclusais. Em seguida, toda a amostra foi imersa em corante Rodamina B a 0,5% a 37°C, por um período de sete dias, para difusão passiva do corante. Em sequência, os materiais restauradores temporários foram removidos para avaliação da infiltração. Todos os dentes examinados, exceto os controles negativos, apresentaram infiltração pelo corante, manchando a esponja contida na câmara pulpar. Todos os dentes selados com COLTOSOL fraturaram após ensaio mecânico, enquanto que aqueles com IRM e Fill Magic TEMPO mantiveram-se intactos macroscopicamente. Pôde se concluir que nenhum dos materiais testados impediu a penetração do corante. Não houve correlação entre a ação ou não das intempéries térmicas e mecânicas quanto à penetração do corante nas amostras no presente estudo. / The aim of this study was to evaluate "in vitro", the coronal microleakage in complex cavities class II-MOD sealed with temporary filling materials, subjected to the action of thermal cycling and mechanical forces. Cavities MOD were prepared in 60 premolars extracted from humans who were divided into three groups according to the temporary restorative material (MRT) used: G1-IRM; Coltosol-G2, G3-Fill Magic Tempo. Three teeth served as negative control and had no cavities prepared. Before sealing the cavities with the MRT a collagen sponge was left in the pulp chamber to evaluate binary penetration of the dye. Ten specimens of each group were subjected to the action of thermal cycling and mechanical occlusal forces. Then, the whole sample was immersed in the dye Rhodamine B 0.5% at 37 ° C for a period of seven days to passive diffusion of the dye. In sequence, the temporary restorative materials were removed to evaluate infiltration in the collagen sponge. All teeth examined, except the negative controls showed infiltration by the dye, staining the sponge contained in the pulp chamber. All teeth sealed with Coltosol fractured after mechanical testing, while those with IRM and Fill Magic Tempo remained macroscopically intact. Could be concluded that none of the tested materials to prevent dye penetration. There was no correlation between the action or not of the thermocycling and mechanical loading in the dye penetration of the samples in this study.
48

COMPARAÇÃO IN VITRO DE DIFERENTES MATERIAIS USADOS EM RETROBTURAÇÕES / IN VITRO COMPARITIONS OF DIFERENT MARTERIALS USED IN RETROFILLINGS.

Perez, Walter Blaya 09 March 2010 (has links)
This research intended to evaluate three different materials, in vitro, for their capacity of sealing in root-end fillings. The sample was consisted by 30 single root teeth, having primarily realized root canal treatment and subsequently resected three mm from the apex, in an angle of 90° in relation to its long axis and in its apex, cavities with ultrasonic tips were prepared. Subsequently they were retro filled with different materials, randomized divided in three groups of ten teeth each, according to the retrofilling product. Group 1: mineral trioxide aggregate (gray MTA Angelus®); Group 2: mineral trioxide aggregate (MTA Endo Sealer CPM®) and Group 3: a phosphate tricalcium cement. Its evaluation in relation to the apical sealing was obtained through the microleakage test with the Rodamine B solution 0.2%. Subsequently, the teeth were sectioned in their long axis by taking one of the parts and evaluating it in a dentistry microscope. Their images were captured and analyzed in the Image Tool 2.0 Software to determine the microleakage zones. The data was statistically analyzed using the STATA 9.0 program. First, an exploratory analysis of the data was realized referring to the studied variables. The dependent variable considered in this study was the percentage of stained dentin, regardless of the type of sealant used in each resected root. The differences between the values of microleakage in each material were statistically evaluated by the Kruskal-Wallis test considering a minimum level of sufficiency up to 5%. Before the analysis, the Schapiro-Wilk test was applied to verify the normality of the data distribution. According to the test, a pattern of non-normal distribution of the dependent variable (p=0.002) could be observed. Higher values of infiltration could be observed in the group that used a tricalcium phosphate cement in relation to groups that used mineral trioxide aggregate (gray MTA- Angelus®) and mineral trioxide aggregate (MTA Endo Sealer CPM®) (p<0.001). There was no significant difference in the values of infiltration between the MTA / Esta pesquisa teve por alvo a avaliação de três diferentes materiais, in vitro, quanto à sua capacidade de selamento em retrobturações. A amostra foi constituída por 30 dentes monorradiculares, tendo, primeiramente, realizado tratamento endodôntico e posteriormente apicetomizados a três mm do ápice, em um ângulo de 90° em relação ao seu longo eixo e, em seu ápice, confeccionadas cavidades com pontas ultrassônicas. Posteriormente foram retrobturados com materiais diferentes: divididos em três grupos aleatoriamente de dez dentes cada um, de acordo com o produto retrobturador. Grupo 1, agregado trióxido mineral (MTA cinza - Angelus®), Grupo 2, agregado trióxido mineral (MTA - CPM Endo Sealer®) e Grupo 3, cimento de α fosfato tricálcio. Sua avaliação em relação ao vedamento apical foi obtida através do teste de microinfiltração com a solução de Rodamina B 0,2%. Posteriormente os dentes foram seccionados em seu longo eixo, tomando-se uma das partes e, avaliando-se em microscópio Odontológico, suas imagens foram captadas e analisadas no Software Imagem Tool 2.0, para determinar as zonas de microinfiltração. Os dados foram analisados estatisticamente, utilizando-se o programa STATA 9.0. Primeiramente se realizou a análise exploratória dos dados referentes às variáveis estudadas. A variável dependente considerada neste estudo foi o percentual de dentina corada, independentemente do tipo de material selador utilizado na apicectomia. As diferenças entre os valores de microinfiltração em cada material foram avaliadas estatisticamente através do teste de Kruskal-Wallis, considerando um nível mínimo de suficiência de até 5%. Previamente às análises, foi aplicado o teste de Schapiro-Wilk para verificar a normalidade de distribuição dos dados. De acordo com o teste, observou-se um padrão de distribuição não-nomal das variáveis dependentes. Maiores valores de infiltração puderam ser observados no grupo que utilizou o cimento de α fosfato tricálcio em relação aos grupos do agregado trióxido mineral (MTA cinza - Angelus®) e agregado trióxido mineral (MTA - CPM Endo Sealer®) (p<0,001). Não houve diferença estatisticamente significativa nos valores de infiltração entre os MTA (p>0,05).
49

Microinfiltração e corrosão por Streptococcus mutans na interface pilar protético/implante dentário de titânio

Caroline Ribeiro Serrão 02 October 2007 (has links)
In the field of implantology, is recognized that microleakage at abutment/implant interface may cause inflammatory reactions in the peri-implant tissue. Although its established that microorganisms cause corrosion on metals in water environments, the role of bacteria at corrosion of dental alloys is unknown. The corrosion may result in biological, functional and aesthetic effects. The aim of this in vitro experiment is to evaluate the microleakage and corrosion by Streptococcus mutans at implant/abutment interface. The evaluated abutments are the following: premachined UCLA of Ag-Pd, premachined UCLA of tilite, calcinable UCLA of Co-Cr, calcinable UCLA of tilite, tilite preparable trunion and titanium preparable trunion. The inner of implants were contaminated with Streptococcus mutans culture. The abutments were screwed on implants, receiving closing torques of 32 N.cm and immerse in thioglycolate, keeping incubated for 28 days. The microleakage was evaluated in each 24 hours, for 14 days. After that, the culture environments that werent bleary were contaminated. The culture environments were analyzed in the 7th, 14th and 28th days, with atomic absorption spectrophotometry, for corrosion analyze. With exception of the prosthetic component of Ag-Pd, all the tested components had an increase in the corrosion when immersed in way contend Streptococcus mutans, of significant form or not, and the premachined UCLA of Ag-Pd presented higher percentage of microleakage (40%), but without difference significant statistics for the others tested groups. / No âmbito da implantodontia é reconhecido que a microinfiltração na interface implante/pilar protético pode causar reações inflamatórias no tecido perimplantar. Apesar de estabelecido que microrganismos causem corrosão de metais em meio aquoso, a ação das bactérias na corrosão de materiais odontológicos tem sido pouco estudada. A corrosão pode gerar problemas biológicos, funcionais e estéticos. O objetivo deste trabalho foi avaliar in vitro a microinfiltração e corrosão por Streptococcus mutans na interface implante/pilar protético. Foram avaliados pilares protéticos tipo UCLA calcinável fundidos em liga de Co-Cr e tilite, UCLA com cinta metálica pré-fabricada em duas diferentes ligas (Ag-Pd e tilite) e dois tipos de pilar reto personalizável (titânio grau 5 e tilite). O interior dos implantes foi inoculado com S. mutans, os pilares protéticos aparafusados sobre os implantes, recebendo torque de 32 N.cm e imersos em caldo tioglicolato, onde permaneceram incubados por até 28 dias. A microinfiltração foi avaliada a cada 24 horas por 14 dias e depois, os grupos que não apresentaram turvação, foram inoculados e incubados por mais 14 dias. Depois de sete, 14 e 28 dias de incubação, o meio de cultura foi analisado por espectrofotometria de absorção atômica. Com exceção do componente protético de Ag-Pd, todos os componentes testados tiveram um aumento na corrosão quando imersos em meio contendo Streptococcus mutans, de forma significativa ou não e os pilares UCLA com cinta pré-fabricada em Ag-Pd apresentaram maior porcentagem de microinfiltração (40%) embora sem diferença estatística significativa para os demais grupos testados.
50

Influência do tipo de preparo na adaptação interna e infiltração marginal em laminados cerâmicos /

Pierre, Fernanda Zapater. January 2019 (has links)
Orientador: João Mauricio Ferraz da Silva / Banca: Virgílio Vilas Boas Fernandes Jr. / Banca: Rodrigo Máximo de Araújo / Resumo: Este estudo laboratorial teve como objetivo avaliar a infiltração marginal, adaptação interna e gap cervical de laminados cerâmicos, em função da realização ou não de preparo. Método: Vinte e quatro incisivos centrais superiores hígidos, com volumes e tamanhos padronizados, foram subdivididos em dois grupos, n=12, de acordo com o tipo de preparo. GRUPO CP - minimamente invasivo com linha de término na extensão do preparo; GRUPO SP - sem preparo, somente remoção de áreas retentivas. Todos os espécimes foram moldados com silicone de adição (Virtual Ivoclar - Vivadent), e sobre os modelos obtidos foram confeccionados laminados em cerâmica de Dissilicato de Lítio (Emax Press Ivoclar-Vivadent) com espessuras entre 0.3/0.7mm. Após ajustes, as peças foram cimentadas com cimento resinoso fotopolimerizável (Variolink Esthetic LC Ivoclar - Vivadent), seguindo as recomendações do fabricante. Em seguidas os espécimes foram envelhecidos em cicladoras térmica, 6.000 ciclos de 5 a 55ºC, e mecânica com 100N por 100.000 ciclos. Após o término das ciclagens todos foram imersos em substância corante por 24 horas e cortados paralelamente ao eixo do dente e horizontalmente para avaliação da infiltração marginal, adaptação interna e gap cervical em esteriomicroscópio. Os resultados apontaram que, na infiltração marginal, o grupo CP teve a maior média na região cervical (1,601 mm) comparado ao grupo SP (1,471 mm), porém não estatisticamente significante. Em ambos os grupos a infiltração marginal na... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract : This laboratory study aimed to evaluate the marginal infiltration, internal adaptation and cervical gap of ceramic laminate venners, by whether or not preparation. Method: Twenty-four upper central incisors with standard volumes and sizes were subdivided into two groups, n = 12, according to the type of preparation. CP GROUP - minimally invasive with finishing line in preparation extension; GRUPO SP - without preparation, only removal of retentive areas. All the specimens were molded with addition silicone (Virtual Ivoclar - Vivadent), on the obtained models laminates in ceramic of Lithium Dissilicate (Emax Press Ivoclar - Vivadent) were made with thicknesses between 0.3 / 0.7mm. After adjustments, the pieces were cemented with photopolymerizable resin cement (Variolink Esthetic LC Ivoclar - Vivadent), following the manufacturer's instructions. Then the specimens were aged in thermal cycling machine, 6,000 cycles of 5 to 55ºC, and mechanical with 100N per 100,000 cycles. After the cycling, all specimens were immersed in dye substance for 24 hours and cut parallel to the axis of the tooth and horizontally for evaluation of marginal infiltration, internal adaptation and cervical gap in stereomicroscope. The results showed that, in marginal infiltration, the CP group had the highest mean in the cervical region (1.601 mm) compared to the SP group (1.471 mm), but not statistically significant. In both groups the marginal infiltration in the cervical region was greater than in the proximal one, differing statistically. Internal adaptation was better in the CP group in the three thirds analyzed, but only in the cervical third there was a statistically significant difference. The cervical gap had lower values in the SP group, but without statistically significant difference. It was concluded that the type of preparation did not have significant influence in terms of marginal.. (Complete abstract click electronic access below) / Mestre

Page generated in 0.0514 seconds