• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 167
  • 7
  • 7
  • 7
  • 6
  • 5
  • 2
  • 1
  • Tagged with
  • 170
  • 170
  • 101
  • 50
  • 44
  • 30
  • 29
  • 17
  • 16
  • 15
  • 14
  • 14
  • 13
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Efeito do envelhecimento hidrotérmico na resistência flexural, rugosidade, módulo de Weibull e microestrutura da zircônia monolítica submetida a desgastes e métodos de acabamento de superfície /

Hatanaka, Gabriel Rodrigues. January 2018 (has links)
Orientador: Gelson Luis Adabo / Resumo: Desgastes para ajustes clínicos são necessários para adequada adaptação de próteses em zircônia, mas ainda não há um protocolo estabelecido. Este estudo avaliou o efeito de desgaste e polimento sobre a resistência à flexão (RF) e módulo de Weibull, rugosidade (Ra) e transformação de fase por microscopia eletrônica de varredura (MEV) de duas zircônias monolíticas (Prettau e Prettau Anterior) submetidas à degradação hidrotérmica (LTD). Foram obtidos corpos-de-prova com 20 x 4,0 x 1,2 mm, sem desgaste e com glaze (grupo controle) ou com 20 x 4,0 x 1,5 mm, os quais foram desgastados com fresa diamantada de granulação grossa (90-120 μm) em alta rotação sob irrigação. Após desgaste de 0,3 mm, foram realizados os protocolos de acabamento: sem polimento (D); polimento com borracha diamantada (DP); aplicação de glaze (DG); polimento com borracha diamantada + glaze (DPG). Metade dos corpos-de-prova foi envelhecida hidrotermicamente (EH) em autoclave (134 °C, 2 bars, 20 horas). Os dados de RF e Ra (n=30) foram analisados por teste de Kruskal-Wallis, testes complementares de Dunn e Student-Newman-Keuls, respectivamente (α=0,05). Nos grupos não envelhecidos, o material Prettau apresentou a seguinte ordem de resistência: D = DP > DPG > DG = C, e o Prettau Anterior: D = DP = C > DG = DPG. Após EH, para Prettau: D = DP > DPG > DG = C; e Prettau Anterior DPG = C = D = DP > DG = DPG. O EH aumentou a RF dos grupos D e DP para Prettau e reduziu a RF do grupo DG para Prettau Anterior. O grupo D p... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The CAD/CAM technology allowed prosthesis with accurate fit, but clinical adjustments are still necessary, and there is no protocol in the literature to guide how to provide it. The aim of this study is to evaluate the effect of grinding and finishing procedures on flexural strength (FS) and Weibull moduli, roughness (Ra) and phase transformation by Scanning Electronic Microscopy (SEM) of two monolithic zirconia (Prettau and Prettau Anterior) submitted to low temperature degradation (LTD). It was obtained bar-shaped specimens in the dimensions of 20 x 4.0 x 1.2 mm, without grinding and with glaze (control group) or 20 x 4.0 x 1.5 mm which were ground with diamond burr (90-120 μm) in high rotation and constant water cooling. After 0.3 mm of grinding, the samples were submitted to different finishing protocols: without polishing (D); polishing with diamond rubber (DP); glaze application (DG); polishing with diamond rubber + glaze (DPG). Half of samples was submitted to LTD in autoclave (134 °C, 2 bars, 20 hours). FS and Ra (n=30) data were analyzed by Kruskal-Wallis test and post-hot Dunn and Student-Newman-Keuls, respectively (α=.05). The median FS for Prettau, without LTD, was in the following order: D = DP > DPG > DG = C; Prettau Anterior: D = DP = C > DG = DPG. After LTD, Prettau: D = DP > DPG > DG = C; and Prettau Anterior: DPG = C = D = DP > DG = DPG. LTD increased FS of D and DP Prettau groups, and it decreased FS of DG Prettau Anterior group. Irrespectively of material ... (Complete abstract click electronic access below) / Doutor
32

Efeito do desgaste e ciclo térmico de regeneração sobre o limite de fadiga de uma Y-TZP e sobre a resistência flexural e de união de corpos-de-prova bicamada Y-TZP/cerâmica feldspática /

Polli, Gabriela Scatimburgo January 2018 (has links)
Orientador: José Maurício dos Santos Nunes Reis / Resumo: O objetivo deste estudo foi avaliar o efeito do desgaste e do ciclo térmico de regeneração (R) no limite de fadiga flexural e na caracterização superficial da cerâmica LavaTM Y-TZP e avaliar a influência de métodos de desgaste e do R sobre a resistência à flexão e de união da cerâmica LavaTM Y-TZP recoberta por cerâmica de cobertura. Foram obtidos espécimes em forma de barra (20 x 4,0 x 1,2 mm, n=40; 20 x 4,0 x 1,5 mm, N=80). Metade das barras de 1,2 mm constituíram o grupo controle (C), enquanto as de 1,5 mm foram desgastadas sob irrigação (DI) ou não (D). A outra metade dos espécimes de 1,2 mm e das desgastadas foram submetidas ao R (1000 ºC, 30 min), gerando os grupos CR, DIR e DR. O limite de fadiga (500.000 ciclos, 10 Hz) foi avaliado pelo método de escada. A topografia da superfície (n=3) e a área da fratura (n=3) foram avaliadas por MEV. Transformação de fase foi avaliada por difração de raios-X. Os dados de limite de fadiga foram submetidos ao teste ANOVA dois fatores e Tukey (α=0,05). Além disso, barras (N=72) de Y-TZP nas dimensões 20 x 4,0 x 1,20 mm (Controle (C); n=24) e 20 x 4,0 x 1,50 mm (n=48) foram obtidas. Os espécimes com 1,50 mm de altura foram desgastadas, com fresa diamantada (DF) ou pedra específica para zircônia (DP). Metade dos espécimes do grupo Controle e metade das desgastadas foram submetidas ao R (CR, DFR e DPR). Em seguida, a cerâmica de cobertura IPS e.max Ceram foi aplicada sobre todos os espécimes, sendo a dimensão final dos espécimes de 20 x ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the effect of grinding and regeneration cycle (R) on the flexural fatigue limit and on the surface characterization of LavaTM Y-TZP ceramics and evaluate the influence of grinding methods and of R on the flexural strength and bonding strength between LavaTM Y-TZP and veneering porcelain specimens. Bar-shaped specimens (20 x 4.0 x 1.2 mm, n = 40; 20 x 4.0 x 1.5 mm, N=80) were obtained. Half of the 1.2 mm specimens was the control group (C), while the 1.5 mm specimens were ground under irrigation (DI) or not (D). Half of ground specimens and half of the 1.2 mm specimens were submitted to R (1000 ° C, 30 min), forming the groups CR, DIR and DR. The fatigue limit (500,000 cycles, 10 Hz) was evaluated by the staircase method. Surface topography (n=3) and fracture area (n=3) were evaluated by SEM. Phase transformation was evaluated by X-ray diffraction. Fatigue limit data were analyzed by two-way ANOVA and Tukey tests (α=.05). Moreover, Y-TZP bars (N=72) in the dimensions of 20 x 4.0 x 1.20 mm (Control (C); n=24) and 20 x 4.0 x 1.50 mm (n=48) were obtained. The specimens with 1.50 mm in height were ground, with diamond burs (DF) or zirconia stone (DP). Half of the specimens of the Control group and half of ground ones were submitted to R (CR, DFR and DPR). Then, veneering porcelain (IPS e.max Ceramic) was applied over all specimens, acquiring the final dimension of 20 x 5.0 x 2.4 mm. The monotonic flexural strength test was performed. Data were... (Complete abstract click electronic access below) / Doutor
33

Efeito da ativação ultrassônica de soluções irrigadoras sobre a remoção da lama dentinária

Schmidt, Tamer Ferreira January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T21:08:49Z (GMT). No. of bitstreams: 1 327525.pdf: 1407437 bytes, checksum: f7f5837760eb3625323c0817651ac60e (MD5) Previous issue date: 2014 / O objetivo deste estudo foi avaliar, longitudinal e quantitativamente por meio de microscópio eletrônico de varredura (MEV), a eficácia da irrigação ultrassônica passiva (Passive Ultrasonic Irrigation - PUI) com as soluções de EDTA 17% e NaOCl 1% sobre a remoção da lama dentinária. O preparo químico-mecânico dos canais radiculares de 32 dentes humanos foi realizado com o sistema ProTaper até F4. Em seguida os dentes foram clivados e a superfície dentinária foi analisada no MEV em baixo vácuo. Foram obtidas imagens com aumentos de 500 e 1000x dos terços cervical, médio e apical de áreas previamente determinadas e totalmente recobertas por lama dentinária. Os dentes foram remontados e divididos em 4 grupos que receberam diferentes protocolos de irrigação final: G1 - EDTA + NaOCl, G2 - EDTA com PUI + NaOCl, G3 - EDTA + NaOCl com PUI, G4 - EDTA + NaOCl, ambos com PUI. Depois da irrigação final as metades dos dentes foram novamente separadas e preparadas para análise da superfície dentinária no MEV em alto vácuo. Imagens com os mesmos aumentos foram obtidas das mesmas áreas anteriormente avaliadas e, por meio do software Image J, foi obtida a porcentagem da área dos túbulos dentinários abertos em relação a área total da imagem. Os resultados foram submetidos ao teste de Análise de Variância (ANOVA) e foram utilizados os testes de Kruskal-Wallis ou de Bonferroni para identificar diferenças entre os grupos ao nível de significância de 5%. O terço cervical das amostras de todos os grupos apresentou maior percentual de área de túbulos dentinários abertos, seguido pelo terço médio e o apical. Entre os grupos, houve diferença estatística somente no terço cervical, entre G2 e G4, com maior e menor percentual, respectivamente. O uso da PUI promoveu melhor remoção da lama na região apical, porém sem diferença estatística em relação à irrigação convencional. A PUI não demonstrou maior eficiência na remoção da lama dentinária em comparação com a irrigação convencional.<br> / Abstract : The objective of this study was to evaluate, longitudinal and quantitatively by scanning electron microscope (SEM), the effectiveness of passive ultrasonic irrigation (PUI) of 17% EDTA and 1% NaOCl on smear layer removal. The root canal preparation of 32 human teeth was performed with Protaper system until F4. The teeth were cleaved and dentin surface was analyzed by SEM in low vacuum. Images with increases of 500 and 1000x of the cervical, middle and apical thirds of predetermined areas and totally covered by smear layer were obtained. The teeth were reassembled and divided into 4 groups which received different final irrigation protocols: G1 - EDTA + NaOCl, G2 - EDTA with PUI + NaOCl, G3 - EDTA + NaOCl with PUI, G4 - EDTA + NaOCl, both with PUI. After the final irrigation, the halves of teeth were again separated and prepared for analysis of the dentin surface in SEM on high vacuum. Images with the same increases were made from the same areas previously evaluated and a ratio between surface area of dentinal tubules opened and the total area of the image, expressed as a percentage, was obtained through Image J software. The results were submitted to the analysis of variance test (ANOVA), and Kruskal-Wallis or Bonferroni tests were used to identify differences between groups at a significance level of 5%. The cervical third from all groups samples presented higher percentage of open dentinal tubules area, followed by the middle and the apical third respectively. Amongst the groups, the only difference statistically was observed within the cervical third, between G2 and G4, with the highest and lowest percentage, respectively. The use of PUI promoted better smear layer removal in the apical third, however without significant difference in relation to the conventional irrigation. The PUI did not showed higher efficiency in smear layer removal compared with conventional irrigation.
34

Avaliação da resistência de união sob teste de microtração de uma resina composta de nanopartículas à dentina humana após tratamento clareador interno

Arcari, Gilberto Müller January 2005 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-graduação em Odontologia / Made available in DSpace on 2013-07-16T00:43:33Z (GMT). No. of bitstreams: 1 221575.pdf: 9052785 bytes, checksum: a16f335e68a596da414cc3cdd05eccf0 (MD5) / Este estudo, in vitro, teve como objetivo avaliar a resistência de união sob teste de microtração de uma resina composta de nanopartículas à dentina humana, após clareamento interno com peróxido de hidrogênio associado a perborato de sódio, ou peróxido de carbamida, ou peróxido de hidrogênio, realizado pela técnica do clareamento mediato e por um período de tratamento de 21 dias, com diferentes tempos de espera para a realização do tratamento restaurador, seguido da análise do tipo de fratura em microscópio eletrônico de varredura (MEV). Pré-molares humanos superiores extraídos foram preparados na superfície oclusal, com profundidade média em dentina, com o objetivo de simular a câmara pulpar. Após o preparo, os dentes foram aleatoriamente divididos em quatro grupos: Grupo Controle (não clareado) (n=9); Grupo Experimental 1 (clareado com pasta de perborato de sódio e peróxido de hidrogênio a 30%) (n=9); Grupo Experimental 2 (clareado com gel de peróxido de hidrogênio a 35%) (n=9); e Grupo Experimental 3 (clareado com gel de peróxido de carbamida a 37%) (n=9). Cada grupo foi dividido também aleatoriamente em três subgrupos: dentes restaurados imediatamente após o término do tratamento clareador (n=3); dentes restaurados 7 dias após o término do tratamento clareador (n=3); e dentes restaurados 14 dias após o término do tratamento clareador (n=3). Após 24h da realização da restauração definitiva, os dentes foram seccionados 4mm abaixo da junção cemento/esmalte e a coroa dental submetida a cortes seriais para a obtenção das amostras (filetes) para o teste de microtração com área de secção transversa de 0,9mm2. Os filetes foram individualmente colados a um dispositivo especial de microtração (dispositivo de Geraldeli) e adaptados a uma máquina de ensaios universal (Instron, modelo 4444, Instron Corp., Canton, Mass., EUA). O teste de tração foi realizado até a obtenção da fratura e cada espécime foi analisado ao microscópio eletrônico de varredura (Philips XL-30, Philips Electric Corp.). Para o tratamento estatístico dos dados e com o objetivo de verificar possíveis diferenças entre os grupos, foi empregada análise de variância de dois critérios (Anova 2) (p=0,05). Os valores demonstraram que não houve diferença estatística significativa entre os agentes clareadores utilizados em relação a qualquer um dos tempos de espera para a realização da restauração definitiva.
35

Análise da interface e resistência de união de cimentos endodônticos à dentina radicular após imersão em solução tampão fosfato salino

Tedesco, Maybell January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-12-05T21:25:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2012
36

Avaliação da interface de cinco sistemas de implantes e seus respectivos abutments com auxílio do método de microscopia eletrônica de varredura

Fujiwara, Carlos Alberto [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T20:55:05Z : No. of bitstreams: 1 fujiwara_ca_me_araca.pdf: 1023210 bytes, checksum: d5bfe58a6ad917370b05a41403af9e6f (MD5) / Universidade Estadual Paulista (UNESP) / A adaptação entre a plataforma do implante e seu respectivo abutment deve ser precisa, isto é, sem nenhuma fenda, que é denominada microgap, entre as estruturas. A presença do microgap permite que microorganismos presentes na microbiota bucal migrem para o interior do implante, o que pode ocasionar problemas de natureza inflamatória e ou infecciosa, e, conseqüentemente, causar a perda do implante. Neste estudo utilizamos uma amostragem de 26 (vinte e seis) implantes e seus respectivos abutments provenientes de 5 (cinco) marcas comerciais diferentes: AS Tecnology, Conexão Sistema de Prótese, Neodent Implante Osteointegrado, Sterngold Implamed, e 3i Implant Innovation. Os abutments receberam um torque de 20Ncm. Os cortes longitudinais da interface implante/abutment foram mensurados em 6 (seis) locais com o auxílio da microscopia eletrônica de varredura. Os resultados das mensurações foram submetidos à análise estatística. Foi possível concluir que: 1) A seqüência dos grupos, em relação ao gap encontrado, do menor para o maior, foram: abutment cônico, abutment gold ucla, abutment mult unit. 2) O abutment cônico e o abutment mult unit apresentaram gaps menores que o abutment gold ucla. 3) O ponto interno apresentou gap menor em relação ao ponto médio, o qual foi menor que o ponto externo, portanto, as peças tenderam a convergir para o ponto interno. / The adaptation of the implant platform and its respective abutment must be precise, with no space denominated microgap, between the structures. The presence of a microgap allows microorganisms that are present in the buccal microbiology to migrate into the implant, what could cause inflammatory and/or infectious problems, and consequent loss of the implant. In this study, a sample of 26 (twenty six) implants and their respective abutments was taken: conic, multi unit, and the gold ucla - together with their respective fixing screws. The abutments received a manual torque of 20Ncm. After the manual preparation, the interface implant/abutment longitudinal cuts were measured on 6 (six) different points through an Scanning Electron Microscope (SEM). The results of such measurements were statistically analyzed, and according to the experimental conditions of this study, was possible to conclude: 1) The sequential groups of implants/abutments, in relation to the gap found, from the smaller to the biggest, were: a) conic abutment , b) gold ucla abutment , c) multi unit abutment. 2) The conic and the multi unit abutments showed smaller gaps than the gold ucla abutments. 3) The internal point showed a smaller gap than the middle point, and the middle point, in return, also showed a smaller gap in relation to the external point; therefore, the pieces tended to converge to the internal point.
37

Avaliação da alteração de cor, difusão de peróxido de hidrogênio e citotoxicidade trans-amelodentinária causadas por diferentes técnicas de clareamento dental

Almeida, Letícia Cunha Amaral Gonzaga de [UNESP] 19 July 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-19Bitstream added on 2014-06-13T19:41:13Z : No. of bitstreams: 1 000737189.pdf: 1470673 bytes, checksum: 417b87b0616eab39e7c5a1e6615ebca9 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tem sido demonstrado que o tempo que o clareador permanece sobre o esmalte, a concentração do produto, a espessura do esmalte e da dentina presente em cada grupo de dentes, podem influenciar na penetração do peróxido na câmara pulpar e que esta ocorrência pode estar relacionada à inflamação da polpa e que nem sempre esses fatores estão associados à maior efetividade da técnica. Sendo assim, o objetivo deste estudo foi avaliar a alteração de cor, a citotoxicidade e a difusão do H2O2 causados por diferentes protocolos de clareamento dental. O presente estudo foi dividido em dois capitulos, no capitulo 1 foram estudados protocolos de clareamento de consultório: peróxido de hidrogênio a 35% (PH35%), três aplicaçoes de 15 minutos ou uma aplicação de 45 minutos; e peróxido de hidrogênio a 20% (PH20%) uma aplicação de 45 minutos. No capitulo 2 foram estudados protocolos caseiros: peróxido de carbamida 10% (PC10%), por 3 horas ou 1,5 horas e peróxido de hidrogênio 6% (PH6%), por 1,5 horas ou 45min. Para tanto, discos de esmalte/dentina foram clareados por 7, 14 e 21 dias pela técnica caseira ou receberam 3 sessões de clareamento de consultório, uma por semana. A alteração de cor dos espécimes (E) foi analisada por espectrofotometria de reflexão UV. Discos adaptados a câmaras pulpares artificiais foram posicionados em compartimentos contendo 1 ml de tampão acetato ou meio de cultura, de forma que a superfície dentinária permaneceu em contato direto com estas soluções. Imediatamente após o clareamento, o total de PH foi quantificado no tampão acetato e o meio de cultura foi aplicado por 1h em células MDPC-23, previamente semeadas em placas de acrílico. O metabolismo celular foi avaliado pelos teste MTT e a morfologia celular foi avaliada através de microscopia eletrônica de varredura. No capitulo 1 os resultados mostraram que ao final do tratamento a alteração... / It has been shown that the time that the bleach gel keeps on the enamel, the product concentration, the thickness of enamel and dentin in each group of teeth, among other factors, can influence the penetration of peroxide in the pulp chamber and that this occurrence may be associated with pulp inflammation and tooth sensitivity, and these factors are not associated with higher effectiveness of the technique. Thus, the aim of this study was to evaluate the color change, the cytotoxicity and the diffusion of H2O2 caused by different bleaching protocols. This study was divided into two chapters , in chapter 1 in-office bleaching protocols were studied: 35 % hydrogen peroxide ( 35% HP), three aplications of 15 minutes or an application of 45 minutes; and 20% hydrogen peroxide (20%HP) an application of 45 minutes. At-home protocols were studied in chapter 2: 10% carbamide peroxide (10 % CP ) for 3 hours or 1.5 hours; and 6% hydrogen peroxide (6% HP) for 1.5 hours or 45 min . Therefore, disks of enamel / dentin were bleached for 7, 14 and 21 days by the at-home technique or received 3 in office bleaching sessions, one per week. The color alteration of the specimens (E) was analyzed by spectrophotometry UV reflection. Discs adapted to artificial pulp chambers were placed in wells containing 1 ml of acetate buffer or culture medium, so that the dentine surface remained in contact with these solutions. Immediately after the bleaching, the total of HP was measured in acetate buffer and culture medium was applied for 1h at MDPC -23 cells previously seeded in acrylic plates. Cell metabolism was assessed by MTT assay and cell morphology was evaluated by scanning electron microscopy. In chapter 1 the results showed that at the end of the treatment the color change was similar in all bleaching protocols, noting that although there was less intense penetration of hydrogen peroxide in the group treated with lower concentrations ...
38

Avaliação in vitro do comportamento de resinas compostas, quanto a microdureza , sorção e análise em mev, após desafio ácido e/ou aplicação de soluções fluoretadas

Firoozmand, Leily Macedo [UNESP] 07 December 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-12-07Bitstream added on 2014-06-13T19:41:13Z : No. of bitstreams: 1 firoozmand_lm_dr_sjc.pdf: 644898 bytes, checksum: 6edcf26bc51ae880c00ecd2d32b4debd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desta pesquisa foi o de avaliar in vitro o comportamento de resinas compostas (RC) submetidas ao desafio ácido e/ou aplicação de soluções fluoretadas, através dos testes de microdureza, sorção e análise morfológica em microscopia eletrônica de varredura (MEV). Foram empregadas as RCs: microhíbridas – Z100 (3M), Estelite Σ (J Morita) e nanoparticulada - Filtek™ Supreme (3M), na cor A3, inseridas em matriz de aço-inoxidável com cavidades de 5mm de diâmetro e 2mm de profundidade, fotopolimerizadas por aparelho de luz halógena, XL 3000 (3M) por 40s. Formaram-se 3 grupos contendo 25 corpos-de-prova (cps) de cada RC, num total de 75 cps. Estes foram pesados após a sua confecção em Balança Digital inicialmente e após armazenamento em água destilada por 24h, para a verificação da sorção de água. O teste de microdureza foi realizado com o Microdurômetro Digital Vickers, utilizando 50g de carga por 15s de permanência para a mensuração inicial dos 75 cps. Destes 20 cps de cada RC foram submetidos ao desafio ácido em uma solução des-remineralizante por 10 dias, e 5 permaneceram como controle em água destilada. Os cps foram novamente pesados e submetidos a 2a leitura da microdureza. Em cada grupo de RC metade dos cps (n=10) foi submetida à aplicação tópica do flúor neutro e na outra metade ao FFA 1,23% por 48 min realizando-se posteriormente a 3a leitura da microdureza. Para a avaliação em MEV foram confeccionados outros 6 cps de cada tipo de RC e submetidos ao desafio ácido e soluções fluoretadas sendo que em cada fase, procedia-se a visualização morfológica da superfície. Para os dados de sorção de água foram utilizados os testes ANOVA e Tukey e para os dados de microdureza os testes ANOVA de medidas repetidas, ANOVA split plot e Tukey. / The aim of this study was to assess through hardness test, sorption test and morphological analyses in scanning electronic microscopy (SEM) the composite resin (CR) behavior submitted to the influence of acid challenge (de-remineralization process) and/or topic application of fluoride solutions. The CR: microhybrids - Z100 (3M), Estelite Σ (J Morita) and nanoparticulated - Filtek™ Supreme (3M), with A3 shade were inserted in stainless steel molds of 5 mm diameter and 2 mm depth, and cured with a XL 3000 halogen light curing unit, (3M) for 40s. Three groups were formed with 25 samples of each CR, making a total of 75 samples. They were initially weighed in Digital Scale after they were made and after they were stored for 24h in distilled water to verify the water sorption. For the microhardness test a Vickers Digital Microhardmeter, using 50g load and 30s time was used to measure the initial values of the 75 samples. From this 20 samples of each material were submitted to the acid challenge in a de-remineralized solution for 10 days, and 5 samples were stored in distilled water as a control group. The samples were again weighted and submitted to a second microhardness measure. In each group of the CR half of samples (n=10) were submitted to the topic application of neutral fluoride and the other half to the 1.23% acidulated phosphate fluoride (APF) for 48 min, making subsequently the third microhardness measure. For the SEM evaluation, 6 others samples were made for each CR and submitted to acid challenge and fluoride solutions considering that in each phase, the surface morphologic visualization was made. The ANOVA and Tukey statistical tests were used for the sorption data, and the ANOVA two way, ANOVA split plot and Tukey tests were used for hardness values.
39

Efeito da clorexidina e laser sobre a adaptação externa de resina a base de silorano em cavidade hígida e afetada por cárie

Kabbach, William [UNESP] 01 April 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-04-01Bitstream added on 2014-06-13T20:41:46Z : No. of bitstreams: 1 kabbach_w_dr_arafo.pdf: 1478118 bytes, checksum: 3eac40e31d23cab96b4903cc8c5fe541 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho propõe avaliar a utilização de clorexidina e laser de Er,Cr:YSGG no processo de adesão em cavidades mistas hígidas e afetadas por cárie em relação a adaptação externa de restaurações classe V submetidas a ciclagem térmica. Foram realizados preparos cavitários mistos de classe V vestibular em 36 molares humanos, dos quais metade foram induzidos artificialmente à cárie. Foi feita a remoção da cárie com broca esférica em baixa rotação, permanecendo a dentina afetada. Os dentes foram subdivididos em 6 grupos, cavidade hígida: sem tratamento prévio, utilização de clorexidina e utilização de laser de Er,Cr:YSGG e cariados: sem tratamento prévio, utilização de clorexidina e utilização de laser de Er,Cr:YSGG. Foi empregado o sistema adesivo e restaurador da resina a base de silorano Filtek P90 (3M ESPE, St. Paul, MN, EUA). Os espécimes foram submetidos a 5000 ciclos térmicos (5-55° C em banhos de 60 minutos). Para caracterização da adaptação externa foram obtidas réplicas de epóxi pela impressão da superfície das restaurações. Foi realizada a análise quantitativa da adaptação externa, tanto em dentina hígida quanto afetada, por meio de réplicas de epóxi, utilizando Microscopia Eletrônica de Varredura. Os valores médios em porcentagem de margen não-adaptadas foram 5,41% em esmalte e 6,49% em dentina antes da termociclagem e 25% e 33,7% respectivamente após. As amostras do grupo com cavidade cariada que foram irradiados com laser apresentaram os maiores valores de margem não-contínua. A clorexidina não afetou os resultados na adaptação marginal / This study evaluates the use of chlorhexidine and laser Er,Cr:YSGG in the adesion in cavities mixed healthy and carie affected, in relation to external adaptation on class V restorations subjected to thermal cycling. Cavity preparations were performed mixed class V buccal 36 human molars, half of which were artificially carie induced. Was removed from the cavity with round bur at low speed, the remaining affected dentin. The teeth were divided into 6 groups, cavity healthy: without previous treatment, use of chlorhexidine and the use of Er,Cr:YSGG and carie afected: no previous treatment, use of chlorhexidine and the use of Er,Cr:YSGG. We used adhesive system and restorative resin-based silorano Filtek P90 (3M ESPE, St. Paul, MN, USA). The specimens were subjected to 5000 thermal cycles (5-55° C 60 minutes). To characterize the external adaptation of epoxy replicas were obtained by printing the surface of the restorations. We performed quantitative analysis of external adaptation, both in healthy female and affected dentin, using epoxy replicas, using SEM. The average percentage of non-adapted were 5.41% and 6.49% in enamel dentine before thermal cycling and 25% and 33.7% respectively after. And the group they were carious cavity laser irradiated showed higher non-continuous margin. The clorexidine does not affected the result
40

Análise in vitro da influência de três sistemas de fotopolimerização, através da MEV, na amplitude de fendas axiais em cavidades classe V restauradas com resina composta

Gomes, Osnara Maria Mongruel [UNESP] 19 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-19Bitstream added on 2014-06-13T19:41:16Z : No. of bitstreams: 1 gomes_omm_dr_arafo.pdf: 3437835 bytes, checksum: 3849412cc99b583b3e6178479443829a (MD5) / A contração de polimerização é ainda o maior problema das restaurações de resina composta fotopolimerizável, causando a formação de fendas marginais. O objetivo deste estudo in vitro foi avaliar a formação de fendas axiais em restaurações de resina composta classe V usando três diferentes sistemas de fotopolimerização. Cavidades padronizadas foram executadas nas faces vestibular e lingual de trinta terceiros molares humanos, com margens localizadas abaixo da junção cemento/esmalte. Resina composta foi inserida em dois incrementos usando sistema restaurador Filtek A 110 (3M) e Single Bond (3M). Resina composta foi fotopolimerizada usando três sistema de fotopolimerização: Grupo I: Quartzo tungstênio halogênio (QTH) convencional (dois incrementos com 20 seg - 600 mW/cm2 - Optilux 401 Demetron); grupo II: QTH pulso tardio (primeiro incremento com 3 seg - 200 mW/cm2 + 3 min período de espera + 20 seg - 600 mW/cm2 e segundo incremento com 20 seg - 600 mW/cm2 VIPTM Bisco); grupo III: Diodo emissor de luz azul - LEDs (dois incrementos com 20 seg- 400 mW/cm2 - EliparTMFreeLight - 3M ESPE). Em seguida, os dentes foram colocados em água destilada a 37oC durante 24 horas; e as restaurações foram polidas. Os dentes foram submetidos a ciclagem térmica por ciclos à 10oC + 2oC e 50oC + 2oC, com um tempo de permanência de 15 segundos em cada temperatura, realizando um total de 500 ciclos. Os dentes foram seccionados vestíbulo-lingualmente através de cada restauração sob constante refrigeração. A extensão da fenda entre a parede axial e o material restaurador foi observada sob MEV a 500X. Os valores médios da amplitude foram: GI 3.61 l 5.08 mm; GII 1.12 l 1.77 mm e GIII 1.46 l 2.73 mm. Os dados foram analisados através do teste não paramétrico de Kruskal-Wallis e o teste de comparações múltiplas de Dunn, onde o grupo II... . / Polymerization shrinkage causing marginal gap formation is still a major problem in light curing restorations. The aim of this in vitro study was evaluate the gap formation in axial wall of class V resin composite restorations using three different photocuring technique. Standard cavities were prepared on the buccal and lingual surfaces of 30 human third molars with margins located below the cemento-enamel junction. Resin was inserted in two increments using the restorative system Filtek A110 (3M) and Single Bond (3M). Resin composite were photocured using three polymerization techniques: Group I: Quartz tungsten halogen (QTH) convencional (two increments with 20 sec - 600 mW/cm2 - Optilux 401 Demetron); group II: QTH pulse delay (first increment with 3 sec - 200 mW/cm2 + 3 min waiting period + 20 sec - 600 mW/cm2 and second increment with 20 sec - 600 mW/cm2 VIPTM Bisco); group III: light emitting diode (LEDs) two increments with 20 sec - 400 mW/cm2 - EliparTM FreeLight 3M-ESPE). Before finish and polishing, samples were stored in destiled water at 37ºC for 24 hours. The teeth were termocycled for 500 cycles (10º C l 2º C and 50º C l 2º C) with a dwell time of 15 seconds. The teeth were sectioned buccolingually through each restoration under constant refrigeration. The extend of gaps between the axial dentine wall and the restorative material was assessed under SEM at X500. Results: the mean and range values were as follows: GI 3.61 l 5.08 mm; GII 1.12 l 1.77 mm and GIII 1.46 l 2.73 mm. The data were analyzed by Kruskal-Wallis and Dunn Tests. Group II showed lower values, followed by group III and group I. Group I showed higher values of gaps. Gaps were observed in all groups. Among polymerization technique used in the study, the group II presented the best performance.

Page generated in 0.096 seconds