• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 70
  • 68
  • 48
  • 18
  • 15
  • 6
  • 6
  • 4
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 273
  • 44
  • 34
  • 34
  • 32
  • 32
  • 28
  • 25
  • 24
  • 24
  • 21
  • 21
  • 20
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Možnosti elektrického propojení součástek v automobilových zámcích / Different methods of connecting electrical parts in car locks

Kollár, Pavel January 2011 (has links)
This Diploma thesis is aimed at various ways of connecting electrical parts in car locks. This part of the thesis includes technologies of electric cables, printed circuit boards, lead frames, 3D-MID technology and technology of electroconductive plastics materials. Listed technologies are compared. The aim of the practical thesis portion is the application of electroconductive plastic materials on the given part. For this purpose necessary changes were designed in the provided small series injection mold. The thesis also includes drawing documentation of the designed construction changes in the injection mold, as well as economic appraisal of the prototype manufacturing fees.
252

Návrh technologie výroby svorkovnice přístroje z plastu / Design of manufacturing technology for plastic terminal device

Adamiec, Pavel January 2011 (has links)
The master thesis deals with design to produce terminal using the plastic injection molding. In the first part are theoretical information about injection molding and injection molding with inserts. The second part is a concrete design of production terminal which contains: injection mold design, calculation of the injection parameters, machine selection, technical and economic evaluation of production. Terminal is made of polyamide 66, inserts material is brass. Parts of injection mold assembly are selected from Hasco standards. The main parts of assembly are made of 1.2312 steel. Production cycle is placed on injection machine Allrounder 375 V from Arburg.
253

Analýza vad typu nekovových vměstků v odlitcích hlav motorů a návrh metod jejich odstranění / Analysis of non-metalic inclusions in motor heads castings and suggestion on their remove

Dratnal, Lukáš January 2016 (has links)
Improving the quality of metal castings for serial production of automotive industry, leading to improvements in the properties of casts and their lower costs. This publication analyzes the non-metallic inclusions contained in casts of heads of internal combustion engines, molded of Nemak Czech Republic, Ltd. Tackling includes analysis of size, shape, chemical composition and hardness of the specific non-metallic inclusions. The thesis describes the purity metal holding furnaces and proposals to eliminate inclusions from metal.
254

Analýza přesnosti výroby lamel formy pneumatiky vyráběných SLM technologií / Analysis of SLM production accuracy of sipes for tire molds

Tomeš, Jan January 2016 (has links)
The first part of the diploma thesis is focused on the analysis and evaluation of the current production of sipes by two SLM devices PXL and M2 Cusing, produced by Phenix Systems and Concept Laser companies. The samples of both machines went through the same manufacturing process and the same process of measurement and evaluation, in order to carry out comparison between individual machines. Geometric accuracy, surface roughness, mechanical properties, and material structure of the samples have been compared. For the sipes it was necessary to create a digital evaluation methodology of geometry. In the second part of the thesis, process parameters are selected on the basis of research and further their influence on surface roughness of manufactured sipes is analyzed.
255

Problem i högt fuktbelastade byggnader : Riskbedömning med hjälp av WUFI / Problems in buildings with high moisture load : Risk assessment using WUFI

Wong, Katilla, Bergh, David January 2012 (has links)
Många av Sveriges badhus byggda i slutet av 1900-talet börjar idag visa tecken på kraftiga fuktskador på grund av extrema inomhusklimat. Denna rapport förklarar den allmänna problematiken kring högt fuktbelastade byggnader och berör det fuktskadade badhuset Aquarena i Katrineholm.  Extrem noggrannhet krävs vid montering av ångspärr i en konstruktion, speciellt vid högt invändigt fukttillskott. Optimal placering av fuktspärren i konstruktionens varmare del innebär att fukt aldrig tillåts kondensera och därmed minimeras risken för fuktskador och negativa konsekvenser. Verkligheten visar också att om kunskaper om fukt och fuktskador prioriteras redan i ett tidigt stadium under projektering kan många hundratusentals kronor sparas. Beräkningar av fukttransport har gjorts för tidigare ytterväggskonstruktion i Aquarena (den som drabbats av skador) och nybyggd ytterväggskonstruktion (nyframtagen till återuppbyggnaden) i datorprogrammet WUFI Pro 4.2 och analyserats i WUFI Bio 3.0.  Beräkningarna visar att den tidigare väggkonstruktionen får de skador som undersökningar av den visat och att skadorna hade kunnat undgås om genomförningar i ångspärren hade utförts på ett korrekt sätt.  Vi har med beräkningar inte kunnat bevisa att alla delar i den nybyggda ytterväggskonstruktionen kommer fungera perfekt. Främst beror osäkerheten i beräkningar utförda i WUFI på att beräkningsmodellen inte är färdigutvecklad. Osäkerheter beror också på otillräcklig kännedom av egenskaper hos de simulerade materialen. Beräkningar för den nyframtagna väggkonstruktionen visar dock entydigt på bättre resultat än för den tidigare väggkonstruktionen. Det finns därför anledning att vidare utreda vilka värden på fukt och temperatur som kommer att råda över de närmaste åren. Detta bland annat för att senare kunna korrigera beräkningsmodellen efter verkligheten. / Many of Sweden's public indoor swimming pools built in the late 1900’s are beginning to show signs of excessive moisture damage due to extreme indoor climate. This report explains the general problem of high moisture-loaded buildings and involves the moisture-damaged public indoor swimming pool Aquarena in Katrineholm. Extreme care is required when assembling the moisture barrier in a structure, especially with high internal moisture content. Optimal placement of the moisture barrier in the warmer parts of the construction means that moisture is never allowed to condense, thus minimizing the risk of moisture damage and negative consequences. Reality also shows that if risks of moisture and moisture damages are assessed early in the planning process, amounts in the range of hundreds of thousands of Swedish crowns can be saved. Calculations of moisture transport have been made for the previous exterior wall structure (the one that suffered damage) and new exterior wall structure the (new design for the reconstruction) using the computer program WUFI Pro 4.2 and analyzed in WUFI Bio 3.0. Calculations show that the old exterior wall structure in Aquarena would have been able to withstand moisture damage and damages due to moisture if joints and transitions in the moisture barrier had been correctly performed.  Calculations have not proven that all elements of the newly built wall design will work perfectly. The main reason for uncertainty in calculations when using WUFI is that the calculation model is not fully developed. Uncertainty is also due to insufficient knowledge of properties of the simulated materials. However, calculations show unambiguously better results than the previous wall construction. It is therefore necessary to further investigate what values of humidity and temperature will exist over the next few years to be able to later on correct the calculation model after reality.
256

Hur skall en ishallsvägg byggas? : Fuktrisker och mögelanalys / How should an ice hall wall be built? : Moisture risks and mold analysis

Yousif, Shather, Douglah, Amir January 2017 (has links)
In Sweden there are many ice halls and ice halls climate differ from the usual buildings' climate, because temperatures are lower indoors than outdoors during the summer months. This results in a higher vapor content outdoors compared with indoors during the course of the year. Moisture transport takes place from the outside towards the ice halls, which is contrary to what happens in a common building. During the critical period, the vapor transport direction is inward. When the hot air hits the cold surface of the wall structure, it leads to a risk of condensation in the wall that leads to moisture damage. Moisture damage can impair the wall structure and lead to unwanted consequences. The purpose of this study was to dimension a number of walls that meet climate conditions, which are done by dynamic humidity calculation in WUFI Pro 5.1 with adapted climate data and real climate data and then mold analysis in WUFI Bio. The aim of the bachelor thesis work was that the results from this study can then be used as a guide to the future building of ice skating walls. The results from WUFI Pro 5.1 and WUFI Bio have shown that a number of walls designed during this master thesis are judged to work as well as revealed how an ice hallway wall should not be constructed. The conclusion shows that climate conditions control the design of the wall structure. / I Sverige finns det många ishallar och ishallsklimatet skiljer sig från vanliga byggnaders klimat, detta på grund av att temperaturen är lägre inomhus än utomhus under sommarhalvåret. Detta resulterar i en högre ånghalt utomhus jämfört med inomhus under en del av året. Fukttransporten sker då utifrån och in mot ishallen, det vill säga tvärtemot vad som sker i en vanlig byggnad. Under den kritiska perioden är ångtransportsriktningen inåt. När den varma luften träffar den kalla ytan i väggkonstruktionen, medför det en risk för kondens i väggen som leder till fuktskador. Fuktskador kan försämra väggkonstruktionen och leda till oönskade konsekvenser som exempelvis mögelpåväxt och rötskador. Syftet med studien har varit att dimensionera ett antal väggar som klarar av klimatförutsättningarna, detta gjordes genom dynamisk fuktberäkning i WUFI Pro 5.1 med anpassade klimatdata samt verkliga klimatdata och sedan mögelanalys i WUFI Bio. Målet med examensarbetet var att resultaten från denna studie sedan kan komma att användas som en vägledning till framtida byggen av ishallsväggar. Resultaten från WUFI Pro 5.1 och WUFI Bio har visat att ett antal väggar som konstruerats under detta examensarbete bedöms att fungera samt kommit fram till hur en ishallsvägg inte skall konstrueras. Slutsatesen visar att klimatförutsättningarna styr dimensioneringen av väggkonstruktionen.
257

Fuktstudie om uteluftsventilerade vindar med beräkningsprogrammet Simple Cold Attic Model från Annex 55 / Moisture related Study in outdoor air ventilated attics with the calculation program Simple Cold Attic Model from Annex 55

Holck-Clausen, Jens, Mattisson, Karin January 2014 (has links)
Fuktskador på uteluftsventilerade vindar är ett ökat problem, i det mer miljömedvetna Sverige. Genom tjockare vindsbjälklagsisolering minskar både energiförlusten genom bjälklaget och uppvärmningsbehovet i huset, men hur många funderar på vad som händer med det förändrade klimatet på vinden och hur det kan påverka fuktförhållandena i utsatta delar av konstruktionen. Studier från Chalmers Tekniska Högskola har framställt ett fuktberäkningsprogram för uteluftsventilerade vindar vid namn Simple Cold Attic Model. Programmets funktion och potential har prövats i denna rapport genom en beräkningsanalys av en uteluftsventilerad vindskonstruktion. Försök till att förbättra fuktsäkerheten i konstruktionen har utförts och redovisas i rapporten.  Studien har påvisat att den studerade konstruktionen inte är fuktsäker om den uppförs i Stockholmsområdet. Det visades även att aktiva val i konstruktionen kan förebygga fuktskador.  Studien har påvisat vikten av inte beräkna med medelår för klimat och hur det påverkar beräkningsresultatet av mögeltillväxt. Detta har understrukit vikten av att ha ett beräkningsprogram som Simple Cold Attic Model som kraftigt reducerar beräkningsmängden vid fuktriskbedömning.  Rekommendationen till företaget AK Konsult är att tillämpa beräkningsprogrammet när det har utvecklats till fullo. / Moisture Damage in outdoor air ventilated attics is a growing problem in the more environmentally conscious Sweden. Thick ceiling insulation reduces both energy loss through the soffit and the need for heating in the house, but how many people are thinking about what happens to the changing climate on the wind and how it can affect moisture conditions in deprived parts of the structure.Studies from Chalmers University of Technology have resulted in a moisture calculation program for outdoor air ventilated attics named Simple Cold Attic Model. The program's performance and potential have been examined in this report, through a calculation analysis of an outdoor air ventilated attic construction. Attempts to improve the moisture safety in the construction have been carried out and are presented in this report.The study has demonstrated that the studied structure is not moisture-proof if it is built in the Stockholm area. It also shows that an active choice in the design can prevent moisture damage. The study has shown the importance of not calculating with an average year for climate and how it affects the calculation result of mold growth. This emphasizes the importance of having a calculation tool as Simple Cold Attic Model, that significantly reduces the amount of calculations in the assessment of moisture related damage. The recommendation for AK Konsult is to apply the calculation program when it is fully developed.
258

Détermination des coefficients de partage sang:air, urine:air et plasma:air de composés organiques volatils d’origine microbienne

Berkane, Wissam 12 1900 (has links)
Résumé: De nombreuses études ont établi que l’exposition aux moisissures intérieures peut être nuisible à la santé. Dans une récente étude, 21 composés organiques volatils microbiens (COVM) ont été sélectionnés comme biomarqueurs potentiels de l’exposition aux moisissures intérieures. L’objectif du projet était de déterminer les coefficients de partage (CP) sang:air, urine:air, plasma:air et eau:air pour ces composés, paramètres utilisés dans la prédiction de la toxicocinétique des xénobiotiques. Pour y parvenir, la méthode de flacons à l’équilibre a été utilisée. Les COVM (1.57-2.01 µg) injectés dans des flacons (20 ml) hermétiquement scellés contenant soit 0.5 ml de matrice (flacons test) ou simplement de l’air (flacons références) ont été incubés 60 min à 37⁰ C sous agitation continue. La quantification des COVM dans l’espace de tête des flacons (test et références) a été ensuite faite par chromatographie en phase gazeuse couplée à la spectrométrie de masse (GC-MS/MS). Les CP de 19 COVM variaient entre 78 et 4721 pour sang:air, 14 et 3586 pour urine:air, 64 et 5604 pour plasma:air et 16 et 2210 pour eau:air. Les CP eau:air étaient étroitement liés aux CP urine:air pour 17 COVM (R2 = 0,97, pente =1,001) suggérant que la valeur de CP eau:air (lorsqu’inférieur à103) peut être un substitut au CP urine:air. L’étude des ratios sang:urine indique que six COVM seraient nettement plus concentrés dans le sang, matrice de choix pour ces composés. Les données générées par cette étude faciliteront le développement de modèles pharmacocinétiques de COVM et le paramétrage de leurs prélèvements en tant que biomarqueurs de l’exposition aux moisissures intérieures. / Abstract: Numerous studies have established that exposure to indoor molds can be harmful to health. In a recent study, 21 microbial volatile organic compounds (mVOCs) were selected as potential biomarkers of indoor mold exposure. The objective of the project was to determine the blood:air, urine:air, plasma:air, and water:air partition coefficients (PCs) for these compounds, parameters used in predicting the toxicokinetics of xenobiotics. To achieve this, the vial-equilibration method was used. mVOCs (1.57-2.01 µg) were injected into hermetically sealed vials (20 ml) containing either 0.5 ml of matrix (test vials) or simply air (reference vials) and were incubated for 60 min at 37 ⁰C under continuous agitation. Quantification of mVOCs in the headspace of the vials (test and reference) was then performed by gas chromatography mass spectrometry (GC-MS/MS). The PCs of 19 mVOCs ranged from 78 and 4721 for blood:air, 14 and 3586 for urine:air, 64 and 5604 for plasma:air, and 16 and 2210 for water:air. Water:air PCs were closely related to urine:air PCs for 17 mVOCs (R2 = 0.97, slope =1.001) suggesting that the water:air PC value (when less than 103) may be a surrogate for the urine:air PC. The blood:urine ratio study indicates that six mVOCs would be significantly more concentrated in blood, the matrix of choice for these compounds. The data generated from this study will facilitate the development of pharmacokinetic models of mVOCs and the parameterization of their sampling as biomarkers of indoor mold exposure.
259

Arbetsgång efter brand i en kulturhistorisk byggnad : Med fokus på återställandet av konstruktionen / Work process after fire in a cultural historic building : With focus on restoration of the construction

Lundgren Mårtensson, Linda, Björkman Ioannou, Stephanie January 2019 (has links)
I aktuellt läge [2019] brister Sverige på att tillhandahålla förberedande planer för eventuella brandolyckor i byggnader med kulturhistoriskt värde. Brandolyckor på kulturminnesmärkta byggnader är inte frekventa och det saknas en standardiserad metod på hur återställandet kan hanteras efter en brandolycka på ett produktivt och hållbart sätt. Syftet med rapporten är att komma fram till en förenklad och mätbar standardiserad arbetsprocess genom att förbättra arbetet kring en brandolycka på kulturminnesmärkta byggnader, där förebyggande åtgärder, förbättringar under brandförloppet och återställande av objekt ingår. Rapporten görs med målen att bevara en god social hållbarhet och bevara det svenska kulturarvet för framtida generationer. Målet vid återställandet av en kulturhistorisk byggnad är att utseendet ska förbli oförändrat och att bevara det traditionella och ursprungliga skicket. Huvudobjekt som undersöks är kulturminnesmärkta byggnaden Kasern II på Skeppsholmen tillsammans med de två referensobjekten Katarina kyrka och Vildmannen 7. Huvudobjektet där en brandolycka bryter ut i september år 2016 håller idag [2019] på att återställas efter omfattande fuktskador från släckningsarbetet och brandskador på material som blev utsatta för höga temperaturer. Del av den standardiserade processen är att redovisa hur val av släckmedel kan avgöra omfattningen av fuktskador på materialet i byggnaden och hur släckmedlet och brandrester påverkar närliggande miljö ur ett hållbarhetsperspektiv. Även förebyggande brandskydd och önskvärt brandskydd efter restaureringsarbetet tas med. Rapporten bearbetar materialmässigt främst tegel och trä som oftast utgör den bärande stommen respektive bjälklaget i en kulturhistorisk byggnad. Genom att observera hur trämaterial och murverk reagerar vid hög temperatur och fukt vill författarna bedöma om de kan saneras och återanvändas eller behöver kasseras. Dessutom undersöks med fokus på återställande av konstruktionen, saneringsmetoder för att ta bort brandlukt och mikrobiologisk påväxt på trämaterial. Då målet vid återställande av en kulturminnesmärkt byggnad är att behålla den traditionella utformningen saneras det massiva teglet och träbalkarna i den utsträckning som går för att bevara dem. Dimensionering av brandskydd varierar för olika kulturminnesmärkta byggnader beroende på objektets utformning och ändamål. Som exempel för installation av sprinkler görs en avvägning mellan risk för brand och risk för eventuella fuktskador vid brand. Compressed air foam system [CAFS] är den släckningsutrustning som används under släckningsarbetet på Kasern II, som jämfört med andra släckningssystem avger mindre vatten och på så sätt minimerar fuktskador. Under brandförloppet hjälper aktuella ritningar, dokumentation och insatsplaner räddningstjänsten att utföra ett funktionellt släckningsarbete. Tegel är beständigt mot brand då det bränns under tillverkningsprocessen. Vid en brandolycka kan tegel spricka om sintringstemperatur överstigs eller vid snabb avkylning under släckningsarbete. Sprickor kan åtgärdas med förstärkning av murverk. Sprickor i tegel som är synligt för blotta ögat återanvänds om det inte finns en synlig fysisk skada på materialet. Trämaterialets hållfasthet försämras inte vid exponering av hög temperatur förutom i den brännskadade delen som kallas förkolningsdel och ligger i ytskiktet på balken efter brand. Förkolningsdelen kan mekaniskt hyvlas bort vid sanering. Mekanisk hyvling anses som en relativt enkel saneringsmetod och kräver inga kemiska miljöpåverkande ämnen. / In current situation [2019], Sweden is failing to provide preparatory plans for possible fire accidents in buildings with cultural-historical value. Because fire accidents on monumental buildings do not occur frequently, there is no standardized method on how to manage the restoration after the accident in a productive and sustainable manner. Purpose of the report is to produce a simplified standardized and measurable work process on how to improve arrangements during a fire accident on monumental buildings, where preventive measures, improvements during fire process and restoration of the building are included. The report is written with the aim of preserving good social sustainability and for preserving the Swedish cultural heritage for the future. The goal when restoring a cultural-historical heritage building is to maintain the classical appearance and to preserve the traditional and original condition. The main object reviewed is the cultural heritage building Kasern II on Skeppsholmen together with two more reference objects. The main object, where the fire accident takes place in September 2016, is today [2019] being restored after extensive moisture damage from the extinguishing work and fire damage to the material which was exposed to high temperature. Part of the standardized process is to describe how the choice of extinguishing agent can determine the extent of moisture damage to the material of the building and how pollution from the extinguishing agent and fire residues affect the neighboring environment from a sustainable point of view. Preventive fire protection and desirable fire protection after restoration work are also included. The report materially presents bricks and wood, which most often constitute the supporting structure and the floor structure of a cultural-historical building. By observing how wood materials and masonry react at high temperature and humidity, an assessment is made whether these materials can be decontaminated and reused or need to be discarded. In addition, with focus on restauration of the construction, decontamination methods for removal of fire odor and microbiological growth on wood materials are studied. Goal when restoring a building with cultural heritage is to maintain the traditional construction, therefore the solid brick and wooden beams are to be remedied to the extent required to preserve them. The choice of fire protection installations varies depending on the building's design and purpose. An example is the installation of sprinklers, which is a tradeoff between the risk of fire and the risk of possible moisture damage in the event of fire. Compressed air foam system [CAFS] is the extinguishing equipment used during extinguishing work on Kasern II which, compared to other extinguishing systems, emits less water therefore minimizing moisture damage. During the fire accident, updated drawings, documentation and action plans help the rescue service perform a functional extinguishing work. Bricks are resistant to fire as bricks are burned during manufacturing process. During a fire accident, bricks may crack if the sintering temperature is exceeded or in case of a rapid cooling during extinguishing work. Cracks can be restored with reinforcement on masonry. As cracks in brick are usually visible to the naked eye, bricks are reused if there is no visible physically damage to the material. The strength of wood material does not deteriorate when exposed to high temperature except in the burned part called char, which lies on the surface layer of the beam after fire exposure. The charring part can be mechanically planed away during sanitation. Mechanical planning is regarded as a relatively simple sanitation method and does not require any chemical environmentally impacting substances.
260

Design and Fabrication of Nonconventional Optical Components by Precision Glass Molding

He, Peng January 2014 (has links)
No description available.

Page generated in 0.0515 seconds