• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 10
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 54
  • 54
  • 10
  • 9
  • 9
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Planejamento da expansão de sistemas de transmissão considerando análise de confiabilidade e incertezas na demanda futura /

Garcés Negrete, Lina Paola. January 2010 (has links)
Orientador: Rubén Augusto Romero Lázaro / Banca: Jose Roberto Sanches Mantovani / Banca: Anna Diva Plasencia Lotufo / Banca: Marcos Julio Rider Flores / Banca: Eduardo Nobuhiro Asada / Resumo: Nessa pesquisa tem-se por objetivo a análise teórica e a implementação computacional de duas propostas de solução ao problema de planejamento da expansão de sistemas de transmissão de energia elétrica considerando diferentes fatores relacionados com a confiabilidade do sistema e a adoção dos novos modelos de mercados elétricos. É importante notar, que no planejamento básico não são levados em conta esses importantes aspectos. Dessa forma, uma primeira aproximação considera um critério de confiabilidade para expandir o sistema, de forma que ele opere adequadamente no horizonte de planejamento satisfazendo um nível de confiabilidade pré-definido. O índice de confiabilidade utilizado para exigir esse nível de confiabilidade é o LOLE, que corresponde ao número médio de horas/dias em um período dado (normalmente um ano) no qual o pico da carga horária/diária do sistema possivelmente exceder'a a capacidade de geração disponível. O problema de planejamento considerando a confiabilidade é, portanto, formulado como um problema de otimização que minimiza o investimento sujeito ao critério de confiabilidade. O índice de confiabilidade para o sistema de transmissão é calculado para cada configuração, subtraindo o índice de confiabilidade do sistema de geração do sistema composto geração-transmissão (bulk power system ). Para calcular o índice no sistema composto geração transmissão, utiliza-se uma curva de duração de carga efetiva para este sistema. Esta curva acumulada de carga é obtida de um processo de convolução de outras duas curvas que representam a função de distribuição de probabilidade (FDP) das saídas aleatórias dos componentes do sistema e a curva de duração de carga, respectivamente. A avaliação de confiabilidade no sistema de geração é feita usando um método que calcula o índice de confiabilidade por meio dos momentos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work aims to the theoretical analysis and computational implementation of two proposals for the transmission expansion planning problem considering several factors such as system reliability and new electricity market structures. It is important to observe, that the basic planning does not consider these issues. Therefore, one first approach considers a reliability criterion to expand the system, so that it operates in adequate conditions in the horizon planning while satisfying pre-defined limits in the reliability index. Transmission system reliability criterion regards to LOLE, which refers to the number of hours/days in a specified period of time (normally one year), in which the hourly/daily peak load possibly will exceed the available generation capacity. So, the planning problem considering reliability is formulated as an optimization problem that minimizes the investment subject to probabilistic reliability criterion. Reliability index for the transmission system is calculated for each configuration by subtraction of generation and bulk power reliability indexes. A composite power system effective load curve is used for reliability analysis of the bulk power system. This accumulate curve is obtained convolving two curves, one of them corresponding to a probability distribution function of the random outages of the system components, and the other one corresponding to the load duration curve. Reliability assessment in the generation system is done using a method that calculates the reliability index through the statistics moments of the frequency distribution of equivalents loads. This curve is obtained by convolving the generation units which are dispached in merit order. The proposed model is solved using the specialized genetic algorithm of Chu-Beasley (AGCB). Detailed results on two test systems are analyzed and discussed. A second approach to the transmission expansion... (Complete abstract click electronic access below) / Doutor
52

Planejamento da expansão de sistemas de transmissão considerando análise de confiabilidade e incertezas na demanda futura

Garcés Negrete, Lina Paola [UNESP] 25 February 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-02-25Bitstream added on 2014-06-13T19:19:30Z : No. of bitstreams: 1 garcesnegrete_lpg_dr_ilha.pdf: 1723635 bytes, checksum: ec9b369023c0d16cf9bcbe29a4bc0ada (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Nessa pesquisa tem-se por objetivo a análise teórica e a implementação computacional de duas propostas de solução ao problema de planejamento da expansão de sistemas de transmissão de energia elétrica considerando diferentes fatores relacionados com a confiabilidade do sistema e a adoção dos novos modelos de mercados elétricos. É importante notar, que no planejamento básico não são levados em conta esses importantes aspectos. Dessa forma, uma primeira aproximação considera um critério de confiabilidade para expandir o sistema, de forma que ele opere adequadamente no horizonte de planejamento satisfazendo um nível de confiabilidade pré-definido. O índice de confiabilidade utilizado para exigir esse nível de confiabilidade é o LOLE, que corresponde ao número médio de horas/dias em um período dado (normalmente um ano) no qual o pico da carga horária/diária do sistema possivelmente exceder´a a capacidade de geração disponível. O problema de planejamento considerando a confiabilidade é, portanto, formulado como um problema de otimização que minimiza o investimento sujeito ao critério de confiabilidade. O índice de confiabilidade para o sistema de transmissão é calculado para cada configuração, subtraindo o índice de confiabilidade do sistema de geração do sistema composto geração-transmissão (bulk power system ). Para calcular o índice no sistema composto geração transmissão, utiliza-se uma curva de duração de carga efetiva para este sistema. Esta curva acumulada de carga é obtida de um processo de convolução de outras duas curvas que representam a função de distribuição de probabilidade (FDP) das saídas aleatórias dos componentes do sistema e a curva de duração de carga, respectivamente. A avaliação de confiabilidade no sistema de geração é feita usando um método que calcula o índice de confiabilidade por meio dos momentos... / This work aims to the theoretical analysis and computational implementation of two proposals for the transmission expansion planning problem considering several factors such as system reliability and new electricity market structures. It is important to observe, that the basic planning does not consider these issues. Therefore, one first approach considers a reliability criterion to expand the system, so that it operates in adequate conditions in the horizon planning while satisfying pre-defined limits in the reliability index. Transmission system reliability criterion regards to LOLE, which refers to the number of hours/days in a specified period of time (normally one year), in which the hourly/daily peak load possibly will exceed the available generation capacity. So, the planning problem considering reliability is formulated as an optimization problem that minimizes the investment subject to probabilistic reliability criterion. Reliability index for the transmission system is calculated for each configuration by subtraction of generation and bulk power reliability indexes. A composite power system effective load curve is used for reliability analysis of the bulk power system. This accumulate curve is obtained convolving two curves, one of them corresponding to a probability distribution function of the random outages of the system components, and the other one corresponding to the load duration curve. Reliability assessment in the generation system is done using a method that calculates the reliability index through the statistics moments of the frequency distribution of equivalents loads. This curve is obtained by convolving the generation units which are dispached in merit order. The proposed model is solved using the specialized genetic algorithm of Chu-Beasley (AGCB). Detailed results on two test systems are analyzed and discussed. A second approach to the transmission expansion... (Complete abstract click electronic access below)
53

Synthese von Zeitreihen elektrischer Lasten basierend auf technischen und sozialen Kennzahlen: Grundlage für Planung, Betrieb und Simulation von aktiven Verteilungsnetzen

Dickert, Jörg 20 November 2015 (has links)
Kenntnisse über das prinzipielle Verhalten der Lasten und deren Benutzung durch die Endabnehmer sind im Wesentlichen vorhanden. Viele der aktuell notwendigen Untersuchungen benötigen jedoch Zeitreihen elektrischer Lasten, sogenannte Lastgänge. Mit der Synthese von Zeitreihen elektrischer Lasten können unter Berücksichtigung verschiedenster Anforderungen Lastgänge aufgebaut werden, wobei in dieser Arbeit der Fokus auf Haushaltsabnehmer liegt. Wichtige Eingangsdaten für die Lastgangsynthese sind die technischen Kenngrößen der elektrischen Geräte und die sozialen Kennzahlen zur Benutzung der Geräte durch die Endabnehmer. Anhand dieser Eingangsdaten wird die Lastgangsynthese durchgeführt und werden Anwendungsbeispiele dargestellt. Die Entwicklung von klassischen Versorgungsnetzen hin zu aktiven Verteilungsnetzen ist bedingt durch neue Verbraucher, wie Wärmepumpen, Elektroautos, sowie vielen dezentralen Erzeugungsanlagen. Speziell die fluktuierende Einspeisung durch Photovoltaik-Anlagen ist Anlass zur Forderung nach einem Verbrauchs- und Lastmanagement. Mit dem Verbrauchsmanagement wird die Last an die Einspeisung angepasst und das Lastmanagement berücksichtigt zusätzlich die Versorgungssituation des Netzes. Für die Lastgangsynthese werden die Haushaltsgeräte in fünf Geräteklassen unterteilt, für die spezifische Kennzahlen aus technischer und sozialer Sicht angegeben werden. Diese Kennzahlen sind Leistung pro Gerät oder Energieverbrauch pro Nutzung sowie Ausstattungsgrade, Benutzungshäufigkeiten und Zeiten für das Ein- und Ausschalten der Geräte. Damit wird ein neuer Ansatz gewählt, welcher nicht mehr auf die detaillierte Beschreibung des Bewohnerverhaltens beruht, da die Datenbereitstellung dafür äußerst schwierig war und ist. Vorzugsweise in Niederspannungsnetzen sind mit synthetischen Zeitreihen umfangreiche und umfassende Untersuchungen realisierbar. Es gibt verschiedenste Möglichkeiten, die Zeitreihen zusammenzustellen. Mit Lastgängen je Außenleiter können beispielsweise unsymmetrische Zustände der Netze analysiert werden. Zudem können auch Lastgänge für Geräte bzw. Gerätegruppen erstellt werden, welche für Potenzialanalysen des Verbrauchsmanagement essenziell sind. Der wesentliche Unterschied besteht darin, dass viele Berechnungen nicht mehr auf deterministische Extremwerte beruhen, sondern die stochastischen Eigenschaften der Endabnehmer mit den resultierenden Lastgängen berücksichtigt werden. / Distributed generation and novel loads such as electric vehicles and heat pumps require the development towards active distribution networks. Load curves are needed for the appropriate design process. This thesis presents a feasible and expandable synthesis of load curves, which is performed exemplary on residential customers with a period under review of 1 year and time steps of as little as 30 s. The data is collected for up-to-date appliances and current statics examining the way of life. The main focus lies on the input data for the synthesis and distinguishes between technical and social factors. Some thirty home appliances have been analyzed and are classified into five appliance classes by incorporating switching operations and power consumptions. The active power is the key figure for the technical perspective and the data is derived from manufacturer information. For the social perspective six different customer types are defined. They differ in sizes of household and housekeeping. The social key figures are appliance penetration rate and depending on the appliance class the turn-on time, turn-off time, operating duration or cycle duration. The elaborated two-stage synthesis is efficiently implemented in Matlab®. First, artificial load curves are created for each appliance of the households under consideration of the appliance class. In the second step, the individual load curves of the appliances are combined to load curves per line conductor. The algorithms have been validated in the implementation process by retracing the input data in the load curves. Also, the feasibility of the results is shown by comparing the key figures maximum load and power consumption to data in literature. The generated load curves allow for unsymmetrical calculations of distribution systems and can be used for probabilistic investigations of the charging of electric vehicles, the sizing of thermal storage combined with heat pumps or the integration of battery storage systems. A main advantage is the possibility to estimate the likelihood of operating conditions. The enhancement to further appliances and the changeability of the input data allows for versatile further possible investigations.
54

[en] DEVELOPMENT OF A SIMULATION TOOL FOR CELLULAR NETWORK PLANNING AND PERFORMANCE EVALUATION BASED ON THE SIGNALING LOAD / [pt] DESENVOLVIMENTO DE UMA FERRAMENTA DESIMULAÇÃO PARA PLANEJAMENTO E ANÁLISE DO DESEMPENHO DE REDES CELULARES A PARTIR DA CARGA DE SINALIZAÇÃO GERADA

RODRIGO CESAR D ALBRIEUX DE CARVALHO 14 June 2002 (has links)
[pt] Com o advento dos sistemas celulares de segunda e terceira gerações é esperado que as operadoras se vejam obrigadas a enfrentar um aumento dramático na carga de sinalização que trafega sobre a parte fixa da rede móvel. Apesar disso, são raros os provedores de serviços de comunicações móveis que possuem atualmente a capacidade de prever com relativa precisão o montante desse aumento. Este trabalho apresenta as etapas do desenvolvimento de uma ferramenta de simulação para análise de desempenho de redes de comunicação móvel celular com base na carga de sinalização gerada pelos procedimentos que a mantém em operação. A plataforma de simulação inclui um modelo de mobilidade e teletráfego para caracterizar o processo de geração dos cenários típicos de uma rede móvel celular e um modelo de retardos para representação da rede de sinalização. Ao final do estudo,são apresentados exemplos de aplicação da ferramenta na obtenção de resultados sobre gerência de status, gerência de localização, avaliação da carga de sinalização,dimensionamento da rede de sinalização e análise de desempenho para diferentes configurações de rede. / [en] The advent of second and third generation cellular systems make cellular operators face dramatic increase in the signaling traffic over the fixed part of the mobile network. In spite of this, rare mobile communications service providers are able to forecast the above mention increase and quantify it with reasonable precision. This work describes the development process of a simulation tool for performance analysis of cellular mobile network based on the signaling load generated by the procedures that keeps it working. The simulation platform inlcudes a mobility and teletraffic model to describe the generation process of cellular mobile networks tipical scenarios and a delay model to represent the signaling network. At the end, examples showing the application of the simulation tool to obtain results about status and location management, signaling load evaluation, signaling network planning and performance analysis for different network configurations are presented.

Page generated in 0.0794 seconds