Spelling suggestions: "subject:"110"" "subject:"1110""
1 |
A critical approach to the development of a framework to support the evaluation of information strategies in UK Higher Education InstitutionsBentley, Yongmei January 2005 (has links)
The objective of this thesis has been to develop a framework to support the evaluation of information strategies of UK higher education institutions (REIs). For this study the theoretical and empirical literature was extensively reviewed and four substantial pieces of empirical research were conducted. These included action research CAR), two pieces of ethnographic research, and a case study. The AR analysed problems encountered with a Student Records System at a UK university and identified both immediate and deeper causes for these problems. Ethnography I involved the researcher's participation in the information strategy development process at the same university: This included consideration of the development processes adopted and also the way that decisions were taken. Ethnography II consisted of participant observation at a range of workshops and conferences organised by the Joint Information Systems Committee on information strategy development at UK REIs. These provided a broad picture of information strategy development procedures being adopted across these HEls. The case study investigated in detail the implementation of an information strategy at a university different from that examined in AR and Ethnography I. These empirical investigations all included in-depth interviews. In total 117 people of various levels and backgrounds involved in information strategies and associated information systems within UK HEIs were interviewed. Key findings from the empirical research were: Many HEIs in the process of developing an information strategy, or about to do so, were not fully sure how this should be achieved nor the extent of the likely benefits. Most HEIs implementing information strategies were using top-down directed system approaches, leaving little room for more inclusive bottom-up emergent planning. Information strategies need to be developed and evaluated using strongly human-centred methods, primarily because it became apparent that the successful functioning of such a strategy is dependent on the motivation and competencies of the people who create and use the information. Investigations into aspects of information strategy development and implementation need to focus on people's perceptions of the situation rather than seeking an objective truth independent of the participants. This reflects a Kantian perspective of knowledge. Overall, the empirical findings supported the use of a Critical Systems Thinking approach in the evaluation of information strategies at higher education institutions. The development of the evaluative framework, the main objective of the thesis, took place in two phases: developing the framework based on the literature review and revising the framework from the empirical research investigations involving a process of critical iteration. The first phase identified a range of elements associated with an HErs information strategy, and for each element highlighted the relevant theoretical andlor empirical literature that bears on the issues being addressed. In particular, the framework is strongly influenced by insights drawn from the work of three key social theorists: Kant, Habermas and Foucault. In addition, the framework includes 'guidelines for evaluation', where these are more practical questions to ask and areas to investigate when evaluating a given element ofthe strategy. The second phase took the framework through a series of reflections and revisions based on the findings from the empirical investigations. In each case, insights were gained that related to the use or applicability ofthe framework. By combining the findings from the theoretical and empirical literature with those from the empirical research, the final framework, which is believed to have filled a gap in the theoretical literature, aims to encompass the complexity of information strategy development and implementation within HEIs. The framework reflects a human-centred and Critical Systems Thinking approach, and is designed to allow potential evaluators to identify underlying causes for the success or failure of an information strategy that is implemented at an HEI.
|
2 |
Feature based dynamic intra-video indexingAsghar, Muhammad Nabeel January 2014 (has links)
With the advent of digital imagery and its wide spread application in all vistas of life, it has become an important component in the world of communication. Video content ranging from broadcast news, sports, personal videos, surveillance, movies and entertainment and similar domains is increasing exponentially in quantity and it is becoming a challenge to retrieve content of interest from the corpora. This has led to an increased interest amongst the researchers to investigate concepts of video structure analysis, feature extraction, content annotation, tagging, video indexing, querying and retrieval to fulfil the requirements. However, most of the previous work is confined within specific domain and constrained by the quality, processing and storage capabilities. This thesis presents a novel framework agglomerating the established approaches from feature extraction to browsing in one system of content based video retrieval. The proposed framework significantly fills the gap identified while satisfying the imposed constraints of processing, storage, quality and retrieval times. The output entails a framework, methodology and prototype application to allow the user to efficiently and effectively retrieved content of interest such as age, gender and activity by specifying the relevant query. Experiments have shown plausible results with an average precision and recall of 0.91 and 0.92 respectively for face detection using Haar wavelets based approach. Precision of age ranges from 0.82 to 0.91 and recall from 0.78 to 0.84. The recognition of gender gives better precision with males (0.89) compared to females while recall gives a higher value with females (0.92). Activity of the subject has been detected using Hough transform and classified using Hiddell Markov Model. A comprehensive dataset to support similar studies has also been developed as part of the research process. A Graphical User Interface (GUI) providing a friendly and intuitive interface has been integrated into the developed system to facilitate the retrieval process. The comparison results of the intraclass correlation coefficient (ICC) shows that the performance of the system closely resembles with that of the human annotator. The performance has been optimised for time and error rate.
|
3 |
The regulation of Rab5 by Phosphatidylinositol 3'-Kinase2012 November 1900 (has links)
Rab5 (Ras-related in brain) and Rab4 are small monomeric GTPases that mediate the intracellular trafficking of endocytosed growth factor receptors. Active Rab5-GTP has low intrinsic GTP hydrolysis activity that is stimulated by GTPase activating proteins (GAPs) to make inactive Rab5-GDP. GAPs provide both a catalytic arginine and switch region stabilization functions. The p85 regulatory subunit of phosphatidylinositol 3′-kinase (PI3K) has GAP activity towards Rab5 and Rab4, which is not seen in other PI3Ks. The arginine “finger” residue within p85 is R274. It is unlikely that p85 stabilizes the switch regions of Rab5, which undergo large conformational changes between activation states, because it interacts with both Rab5-GTP and Rab5-GDP. In contrast, the PI3K catalytic subunit p110β binds only Rab5-GTP, suggesting it interacts with the switch regions. Thus, the GAP functions may be provided to Rab5 by the subunits of PI3K acting together, where p85 provides the arginine finger and p110β stabilizes the switch regions. The binding interface of Rab5:p85 was sought using mutations of Rab5 residues not present in the switch regions which were conserved in p85-binding Rab proteins (S84, E106, N113, F145, E172, M175, K179, K180) in GST pull-down experiments with FLAG-p85. The p85 binding site was not resolved with these experiments, suggesting that p85 interaction may involve the contribution of multiple residues of the Rab5 protein. The p110β interaction site on Rab5 was investigated using Rab5 switch region mutants. Pull-down experiments using a stabilized p110 protein construct, where the p85-iSH2 domain was fused to p110 (alpha or beta), were performed. Rab5 mutants I53A, F57A, W74A, Q79L, E80R, Y82A, H83E, L85A, M88A, Y89A and R91E showed reduced p110β binding. All of these residues except E80 and H83 are involved in binding other Rab5 effectors. The Rab5 binding site on p110β was also resolved through mutation of p110β in its Ras binding domain, and includes residues I234, E238 and Y244. This generation of non-binding mutants of both Rab5 and p110β will be invaluable in the characterization of the importance of the p110β:Rab5-GTP interaction for receptor trafficking to endosomes in mammalian cells.
|
4 |
Efeito da presença de depósito calcário formado durante a proteção catódica na absorção de hidrogênio e na fragilização pelo hidrogênio do aço API 5CT P110Simoni, Leonardo January 2016 (has links)
O processo de proteção catódica é amplamente utilizada na indústria do petróleo e gás para a prevenção contra a corrosão. Entretanto, devido às reações catódicas induzidas pelo potencial catódico aplicado pode ocorrer a formação de depósito calcário na superfície de componentes protegidos catodicamente em água do mar. Existe certa incerteza na literatura sobre o papel do depósito calcário na absorção de hidrogênio e consequentemente na fragilização pelo hidrogênio. Assim, o presente trabalho visa investigar sua influência a fim de contribuir para o melhor entendimento da participação dessa camada nesse fenômeno. Para isso, foram realizados testes de permeação eletroquímica de hidrogênio, de tração de baixa taxa de deformação (BTD) e de cronoamperometria no aço API 5CT P110 em três soluções diferentes: água do mar sintética (AMS), água do mar sintética sem Ca2+ e Mg2+ e NaCl 3,5%. Além disso, foram aplicados dois potenciais catódicos: -1000 mVECS e -1500 mVECS. Após o ensaio de tração de BTD e de cronoamperometria as amostras foram analisadas em MEV/EDS. A partir dos resultados obtidos verificou-se que o depósito calcário formado em AMS em -1000 mVECS é formado por uma fina camada inicial rica em Mg seguida de cristais de aragonita. A formação dessa camada aparentemente diminuiu o fluxo de hidrogênio no estado estacionário em comparação com as demais soluções avaliadas nesse mesmo potencial. Todavia, essa diminuição não resultou em uma mudança significativa na fragilização do material. O depósito calcário formado em AMS em -1500 mVECS mostrou-se poroso e pulverulento, apresentando principalmente Mg em sua composição. O fluxo de hidrogênio no estado estacionário e a fragilização do material em AMS em -1500 mVECS foi maior do que nas demais soluções nesse potencial. Um possível mecanismo para explicar o efeito do depósito calcário na absorção e na fragilização pelo hidrogênio foi proposto e indica a competição entre o fator superficial ocasionado pela formação do depósito calcário e a sobretensão em hidrogênio. / The process of cathodic protection is widely used in oil & gas industry to corrosion prevention. However, the cathodic reactions induced by the applied cathodic potential can lead to the calcareous deposit formation on the cathodically protected structure surface in sea water. There is uncertainty about the role of calcareous deposit on hydrogen uptake and consequently on hydrogen embrittlement. Hydrogen electrochemical permeations, slow strain rate and chronoamperometric tests were carried out in three different solutions: artificial sea water, artificial sea water without Ca2+ and Mg2+ and 3.5% NaCl solution. Besides that, two cathodic potentials were applied: -1000 mVSCE e -1500 mVSCE. After slow strain rate and chronoamperometric tests the samples were analyzed in SEM/EDS. According to the obtained results it was observed that calcareous deposits formed in artificial sea water at -1000 mVSCE consists on a thin Mg-rich inner layer and an outer layer of aragonite crystals. The deposit formation apparently decreased hydrogen flux at steady state in comparison with other solutions evaluated at the same potential. The calcareous deposit formed in artificial sea water at -1500 mVSCE was porous, powdery and mainly composed by Mg. The hydrogen flux at steady state and the embrittlement of the material were higher in artificial sea water at -1500 mVSCE than in other solutions at the same potential. A possible mechanism to explain the calcareous deposit effect on hydrogen uptake and on hydrogen embrittlement was proposed and it indicates the competition between the surface effect induced by calcareous deposit formation and the hydrogen overpotential.
|
5 |
Efeito da presença de depósito calcário formado durante a proteção catódica na absorção de hidrogênio e na fragilização pelo hidrogênio do aço API 5CT P110Simoni, Leonardo January 2016 (has links)
O processo de proteção catódica é amplamente utilizada na indústria do petróleo e gás para a prevenção contra a corrosão. Entretanto, devido às reações catódicas induzidas pelo potencial catódico aplicado pode ocorrer a formação de depósito calcário na superfície de componentes protegidos catodicamente em água do mar. Existe certa incerteza na literatura sobre o papel do depósito calcário na absorção de hidrogênio e consequentemente na fragilização pelo hidrogênio. Assim, o presente trabalho visa investigar sua influência a fim de contribuir para o melhor entendimento da participação dessa camada nesse fenômeno. Para isso, foram realizados testes de permeação eletroquímica de hidrogênio, de tração de baixa taxa de deformação (BTD) e de cronoamperometria no aço API 5CT P110 em três soluções diferentes: água do mar sintética (AMS), água do mar sintética sem Ca2+ e Mg2+ e NaCl 3,5%. Além disso, foram aplicados dois potenciais catódicos: -1000 mVECS e -1500 mVECS. Após o ensaio de tração de BTD e de cronoamperometria as amostras foram analisadas em MEV/EDS. A partir dos resultados obtidos verificou-se que o depósito calcário formado em AMS em -1000 mVECS é formado por uma fina camada inicial rica em Mg seguida de cristais de aragonita. A formação dessa camada aparentemente diminuiu o fluxo de hidrogênio no estado estacionário em comparação com as demais soluções avaliadas nesse mesmo potencial. Todavia, essa diminuição não resultou em uma mudança significativa na fragilização do material. O depósito calcário formado em AMS em -1500 mVECS mostrou-se poroso e pulverulento, apresentando principalmente Mg em sua composição. O fluxo de hidrogênio no estado estacionário e a fragilização do material em AMS em -1500 mVECS foi maior do que nas demais soluções nesse potencial. Um possível mecanismo para explicar o efeito do depósito calcário na absorção e na fragilização pelo hidrogênio foi proposto e indica a competição entre o fator superficial ocasionado pela formação do depósito calcário e a sobretensão em hidrogênio. / The process of cathodic protection is widely used in oil & gas industry to corrosion prevention. However, the cathodic reactions induced by the applied cathodic potential can lead to the calcareous deposit formation on the cathodically protected structure surface in sea water. There is uncertainty about the role of calcareous deposit on hydrogen uptake and consequently on hydrogen embrittlement. Hydrogen electrochemical permeations, slow strain rate and chronoamperometric tests were carried out in three different solutions: artificial sea water, artificial sea water without Ca2+ and Mg2+ and 3.5% NaCl solution. Besides that, two cathodic potentials were applied: -1000 mVSCE e -1500 mVSCE. After slow strain rate and chronoamperometric tests the samples were analyzed in SEM/EDS. According to the obtained results it was observed that calcareous deposits formed in artificial sea water at -1000 mVSCE consists on a thin Mg-rich inner layer and an outer layer of aragonite crystals. The deposit formation apparently decreased hydrogen flux at steady state in comparison with other solutions evaluated at the same potential. The calcareous deposit formed in artificial sea water at -1500 mVSCE was porous, powdery and mainly composed by Mg. The hydrogen flux at steady state and the embrittlement of the material were higher in artificial sea water at -1500 mVSCE than in other solutions at the same potential. A possible mechanism to explain the calcareous deposit effect on hydrogen uptake and on hydrogen embrittlement was proposed and it indicates the competition between the surface effect induced by calcareous deposit formation and the hydrogen overpotential.
|
6 |
Determinação do KIHAC do aço API 5CT P110 dopado com hidrogênio em água do mar sintética sob superproteção catódica. / Determination of KIHAC of API 5CT P110 steel doped with hydrogen in synthetic sea water under cathodic overprotection.OLIVEIRA, Misael Souto de. 11 April 2018 (has links)
Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-04-11T15:04:12Z
No. of bitstreams: 1
MISAEL SOUTO DE OLIVEIRA – DISSERTAÇÃO (PPGEM) 2017.pdf: 3567770 bytes, checksum: 102f4839f729d6e1ef1648a5b837db9b (MD5) / Made available in DSpace on 2018-04-11T15:04:12Z (GMT). No. of bitstreams: 1
MISAEL SOUTO DE OLIVEIRA – DISSERTAÇÃO (PPGEM) 2017.pdf: 3567770 bytes, checksum: 102f4839f729d6e1ef1648a5b837db9b (MD5)
Previous issue date: 2017-08-28 / Capes / A interação dos materiais utilizados na fabricação de equipamentos com os ambientes para os quais são colocados em serviço frequentemente causa sua degradação. A fragilização por hidrogênio apresenta-se como um processo de degradação caracterizado pela nucleação e propagação de trincas nos materiais metálicos, como em tubulações utilizadas no setor de petróleo e gás, sendo classificada como uma das mais perigosas para a integridade estrutural, uma vez que pode ocorrer de forma repentina de difícil percepção, resultando em fratura catastrófica. Por conseguinte, é necessário envidar esforços para obter parâmetros e critérios que ajudam na seleção, inspeção e manutenção de equipamentos, onde as condições operacionais favoreçam a ocorrência de um ambiente de fratura assistida. Para isso, foram realizados ensaios com o aço API 5CT P110, pré-dopado com hidrogênio, seguido pela metodologia de passo incremental (step loading), norma ASTM F1624 (2012), em água do mar sintética com superproteção catódica. A solução de água do mar foi preparada de acordo com a norma ASTM D1141 (2013). O início de crescimento de trinca subcrítico foi determinado através da técnica de queda de potencial de corrente alternada. Os resultados mostraram uma diminuição importante na tenacidade à fratura de iniciação do aço e validaram a determinação do limiar de intensidade de tensões (KIHAC) do aço API 5CT P110 em água do mar sintética sob superproteção catódica. / The interaction of materials used in the fabrication of equipment with the environments for which they are put into service often causes their degradation. The hydrogen embrittlement presents as a degradation process characterized by the nucleation and propagation of cracks in metallic materials, as in pipes used in the oil and gas sector, being classified as one of the most dangerous for structural integrity, since it can occurring suddenly and difficult to perceive, resulting in a catastrophic fracture. Therefore, it is necessary to make efforts to obtain parameters and criteria that help in the selection, inspection and maintenance of equipment, where the operating conditions favor the occurrence of an assisted fracture environment. For this, tests were carried out with the API 5CT P110 steel, pre-doped with hydrogen, followed by step loading methodology, ASTM standard F1624 (2012), in synthetic sea water with cathodic overprotection. The seawater solution was prepared in accordance with ASTM D1141 (2013). The beginning of subcritical crack growth was determined by the technique of alternating current potential drop. The results showed a significant decrease in the steel initiation fracture toughness and validated the determination of the stress intensity threshold (KIHAC) of the API 5CT P110 steel in synthetic sea water under cathodic overprotection.
|
7 |
Efeito da presença de depósito calcário formado durante a proteção catódica na absorção de hidrogênio e na fragilização pelo hidrogênio do aço API 5CT P110Simoni, Leonardo January 2016 (has links)
O processo de proteção catódica é amplamente utilizada na indústria do petróleo e gás para a prevenção contra a corrosão. Entretanto, devido às reações catódicas induzidas pelo potencial catódico aplicado pode ocorrer a formação de depósito calcário na superfície de componentes protegidos catodicamente em água do mar. Existe certa incerteza na literatura sobre o papel do depósito calcário na absorção de hidrogênio e consequentemente na fragilização pelo hidrogênio. Assim, o presente trabalho visa investigar sua influência a fim de contribuir para o melhor entendimento da participação dessa camada nesse fenômeno. Para isso, foram realizados testes de permeação eletroquímica de hidrogênio, de tração de baixa taxa de deformação (BTD) e de cronoamperometria no aço API 5CT P110 em três soluções diferentes: água do mar sintética (AMS), água do mar sintética sem Ca2+ e Mg2+ e NaCl 3,5%. Além disso, foram aplicados dois potenciais catódicos: -1000 mVECS e -1500 mVECS. Após o ensaio de tração de BTD e de cronoamperometria as amostras foram analisadas em MEV/EDS. A partir dos resultados obtidos verificou-se que o depósito calcário formado em AMS em -1000 mVECS é formado por uma fina camada inicial rica em Mg seguida de cristais de aragonita. A formação dessa camada aparentemente diminuiu o fluxo de hidrogênio no estado estacionário em comparação com as demais soluções avaliadas nesse mesmo potencial. Todavia, essa diminuição não resultou em uma mudança significativa na fragilização do material. O depósito calcário formado em AMS em -1500 mVECS mostrou-se poroso e pulverulento, apresentando principalmente Mg em sua composição. O fluxo de hidrogênio no estado estacionário e a fragilização do material em AMS em -1500 mVECS foi maior do que nas demais soluções nesse potencial. Um possível mecanismo para explicar o efeito do depósito calcário na absorção e na fragilização pelo hidrogênio foi proposto e indica a competição entre o fator superficial ocasionado pela formação do depósito calcário e a sobretensão em hidrogênio. / The process of cathodic protection is widely used in oil & gas industry to corrosion prevention. However, the cathodic reactions induced by the applied cathodic potential can lead to the calcareous deposit formation on the cathodically protected structure surface in sea water. There is uncertainty about the role of calcareous deposit on hydrogen uptake and consequently on hydrogen embrittlement. Hydrogen electrochemical permeations, slow strain rate and chronoamperometric tests were carried out in three different solutions: artificial sea water, artificial sea water without Ca2+ and Mg2+ and 3.5% NaCl solution. Besides that, two cathodic potentials were applied: -1000 mVSCE e -1500 mVSCE. After slow strain rate and chronoamperometric tests the samples were analyzed in SEM/EDS. According to the obtained results it was observed that calcareous deposits formed in artificial sea water at -1000 mVSCE consists on a thin Mg-rich inner layer and an outer layer of aragonite crystals. The deposit formation apparently decreased hydrogen flux at steady state in comparison with other solutions evaluated at the same potential. The calcareous deposit formed in artificial sea water at -1500 mVSCE was porous, powdery and mainly composed by Mg. The hydrogen flux at steady state and the embrittlement of the material were higher in artificial sea water at -1500 mVSCE than in other solutions at the same potential. A possible mechanism to explain the calcareous deposit effect on hydrogen uptake and on hydrogen embrittlement was proposed and it indicates the competition between the surface effect induced by calcareous deposit formation and the hydrogen overpotential.
|
8 |
Revestimentos de níquel e cobalto aplicados por aspersão térmica por chama hipersônica (HVOF) em aço API 5CT P110Brandolt, Cristiane de Souza January 2014 (has links)
A aplicação de revestimentos obtidos por aspersão térmica por chama hipersônica HVOF vem se tornando uma excelente solução para os desafios encontrados no setor de petróleo e gás natural. Este processo é versátil, podendo ser aplicado em componentes de diversas formas e geometrias, tanto em campo quanto em fábrica, possibilitando o reparo de peças desgastadas, evitando assim a troca completa de componentes. Dentre as opções de materiais a serem aplicados, o níquel e o cobalto se destacam pela boa resistência a corrosão e pelas baixas temperaturas de fusão em relação às temperaturas de operação do processo HVOF, o que propicia a uma completa fusão das partículas, garantindo uma boa qualidade dos revestimentos obtidos. Nesse contexto, o presente trabalho teve por objetivo a obtenção e caracterização de revestimentos de níquel e cobalto aplicados pelo processo de aspersão térmica hipersônica (HVOF) sobre o aço API 5CT P110. A morfologia e a microestrutura dos revestimentos foram analisadas por microscopia eletrônica de varredura (MEV), espectroscopia de energia dispersiva (EDS), difração de raios-X (DRX) e perfilometria. Foi avaliada a dureza dos revestimentos pelo ensaio de microdureza Vickers, e a aderência por ensaio de dobramento. A resistência à corrosão dos revestimentos foi avaliada por monitoramento do potencial de circuito aberto, polarização potenciodinâmica e espectroscopia de impedância eletroquímica em solução de NaCl 3,5 %. Foram obtidas curvas de coeficiente de desgaste por tempo, a partir de ensaios de desgaste a seco e em solução de NaCl 3,5 %. A partir dos resultados obtidos foi possível observar que ambos os revestimentos apresentaram uniformidade química, baixa porosidade e pouca presença de defeitos. Todos os testes eletroquímicos realizados indicaram as camadas de níquel e de cobalto como barreira, impedindo o contato do eletrólito no substrato de aço. Esse efeito foi alcançado graças à escolha correta dos parâmetros envolvidos no processo de aspersão e as características físicas dos elementos aspergidos, principalmente no que tange ao ponto de fusão que permitiu uma união eficiente entre as partículas metálicas no processo de recobrimento, gerando uma camada com poucos defeitos. O revestimento de níquel apresentou melhor desempenho frente à corrosão que o revestimento de cobalto, mas isso aconteceu devido às melhores propriedades do níquel em comparação ao cobalto. De maneira geral, ambos os revestimentos apresentarem uma melhora no desempenho do aço, contudo, o níquel mostrou-se como melhor opção de proteção ao aço API 5CT P110. / The application of thermal spray coatings applied by HVOF hypersonic flame has become an excellent solution to the challenges encountered in the oil and gas industry. This process is versatile and can be applied in components with many geometries, both in field and in the factory, enabling the repair of worn parts, preventing the complete replacement of components. Among the choices of materials that could be used, nickel and cobalt are characterized by good corrosion resistance, and low melting temperatures in relation to the operating temperatures of the HVOF process, which provides a complete fusion of the particles, producing then good quality coatings. In this context, this work aimed to obtain and characterize nickel and cobalt coatings applied by high velocity oxygen fuel (HVOF) thermal sprayed process on a API 5CT P110 steel. The morphology and microstructure of the coatings were analyzed by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), X-ray diffraction (XRD) and profilometry. The hardness of the coatings was evaluated by Vickers microhardness tests, and the adhesion of the coatings was evaluated by bending test. The corrosion resistance of the coatings was evaluated by open circuit potential monitoring, potentiodynamic polarization and electrochemical impedance spectroscopy in 3.5% NaCl solution. Wear rate by time curves were obtained from wear tests on dry and in 3.5% NaCl solution. From the results obtained it was observed that both coatings showed chemical uniformity, low porosity and almost absence of defects. All of electrochemical tests indicated the nickel and cobalt layers as a barrier, preventing the contact between the electrolyte and the steel substrate. This effect was achieved through the correct choice regarding the parameters involved in the spraying process and the physical characteristics of sprayed elements, especially with respect to the melting point which allowed an efficient binding between the metal particles in the coating process, generating a layer with few defects. The nickel coating showed better performance against corrosion than the cobalt coating, but this happened due the better properties of nickel in comparison to cobalt. In general both coatings improve the steel performance, however the nickel coating showed to be the best option regarding the API 5CT P110 steel protection.
|
9 |
Revestimentos de níquel e cobalto aplicados por aspersão térmica por chama hipersônica (HVOF) em aço API 5CT P110Brandolt, Cristiane de Souza January 2014 (has links)
A aplicação de revestimentos obtidos por aspersão térmica por chama hipersônica HVOF vem se tornando uma excelente solução para os desafios encontrados no setor de petróleo e gás natural. Este processo é versátil, podendo ser aplicado em componentes de diversas formas e geometrias, tanto em campo quanto em fábrica, possibilitando o reparo de peças desgastadas, evitando assim a troca completa de componentes. Dentre as opções de materiais a serem aplicados, o níquel e o cobalto se destacam pela boa resistência a corrosão e pelas baixas temperaturas de fusão em relação às temperaturas de operação do processo HVOF, o que propicia a uma completa fusão das partículas, garantindo uma boa qualidade dos revestimentos obtidos. Nesse contexto, o presente trabalho teve por objetivo a obtenção e caracterização de revestimentos de níquel e cobalto aplicados pelo processo de aspersão térmica hipersônica (HVOF) sobre o aço API 5CT P110. A morfologia e a microestrutura dos revestimentos foram analisadas por microscopia eletrônica de varredura (MEV), espectroscopia de energia dispersiva (EDS), difração de raios-X (DRX) e perfilometria. Foi avaliada a dureza dos revestimentos pelo ensaio de microdureza Vickers, e a aderência por ensaio de dobramento. A resistência à corrosão dos revestimentos foi avaliada por monitoramento do potencial de circuito aberto, polarização potenciodinâmica e espectroscopia de impedância eletroquímica em solução de NaCl 3,5 %. Foram obtidas curvas de coeficiente de desgaste por tempo, a partir de ensaios de desgaste a seco e em solução de NaCl 3,5 %. A partir dos resultados obtidos foi possível observar que ambos os revestimentos apresentaram uniformidade química, baixa porosidade e pouca presença de defeitos. Todos os testes eletroquímicos realizados indicaram as camadas de níquel e de cobalto como barreira, impedindo o contato do eletrólito no substrato de aço. Esse efeito foi alcançado graças à escolha correta dos parâmetros envolvidos no processo de aspersão e as características físicas dos elementos aspergidos, principalmente no que tange ao ponto de fusão que permitiu uma união eficiente entre as partículas metálicas no processo de recobrimento, gerando uma camada com poucos defeitos. O revestimento de níquel apresentou melhor desempenho frente à corrosão que o revestimento de cobalto, mas isso aconteceu devido às melhores propriedades do níquel em comparação ao cobalto. De maneira geral, ambos os revestimentos apresentarem uma melhora no desempenho do aço, contudo, o níquel mostrou-se como melhor opção de proteção ao aço API 5CT P110. / The application of thermal spray coatings applied by HVOF hypersonic flame has become an excellent solution to the challenges encountered in the oil and gas industry. This process is versatile and can be applied in components with many geometries, both in field and in the factory, enabling the repair of worn parts, preventing the complete replacement of components. Among the choices of materials that could be used, nickel and cobalt are characterized by good corrosion resistance, and low melting temperatures in relation to the operating temperatures of the HVOF process, which provides a complete fusion of the particles, producing then good quality coatings. In this context, this work aimed to obtain and characterize nickel and cobalt coatings applied by high velocity oxygen fuel (HVOF) thermal sprayed process on a API 5CT P110 steel. The morphology and microstructure of the coatings were analyzed by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), X-ray diffraction (XRD) and profilometry. The hardness of the coatings was evaluated by Vickers microhardness tests, and the adhesion of the coatings was evaluated by bending test. The corrosion resistance of the coatings was evaluated by open circuit potential monitoring, potentiodynamic polarization and electrochemical impedance spectroscopy in 3.5% NaCl solution. Wear rate by time curves were obtained from wear tests on dry and in 3.5% NaCl solution. From the results obtained it was observed that both coatings showed chemical uniformity, low porosity and almost absence of defects. All of electrochemical tests indicated the nickel and cobalt layers as a barrier, preventing the contact between the electrolyte and the steel substrate. This effect was achieved through the correct choice regarding the parameters involved in the spraying process and the physical characteristics of sprayed elements, especially with respect to the melting point which allowed an efficient binding between the metal particles in the coating process, generating a layer with few defects. The nickel coating showed better performance against corrosion than the cobalt coating, but this happened due the better properties of nickel in comparison to cobalt. In general both coatings improve the steel performance, however the nickel coating showed to be the best option regarding the API 5CT P110 steel protection.
|
10 |
Revestimentos de níquel e cobalto aplicados por aspersão térmica por chama hipersônica (HVOF) em aço API 5CT P110Brandolt, Cristiane de Souza January 2014 (has links)
A aplicação de revestimentos obtidos por aspersão térmica por chama hipersônica HVOF vem se tornando uma excelente solução para os desafios encontrados no setor de petróleo e gás natural. Este processo é versátil, podendo ser aplicado em componentes de diversas formas e geometrias, tanto em campo quanto em fábrica, possibilitando o reparo de peças desgastadas, evitando assim a troca completa de componentes. Dentre as opções de materiais a serem aplicados, o níquel e o cobalto se destacam pela boa resistência a corrosão e pelas baixas temperaturas de fusão em relação às temperaturas de operação do processo HVOF, o que propicia a uma completa fusão das partículas, garantindo uma boa qualidade dos revestimentos obtidos. Nesse contexto, o presente trabalho teve por objetivo a obtenção e caracterização de revestimentos de níquel e cobalto aplicados pelo processo de aspersão térmica hipersônica (HVOF) sobre o aço API 5CT P110. A morfologia e a microestrutura dos revestimentos foram analisadas por microscopia eletrônica de varredura (MEV), espectroscopia de energia dispersiva (EDS), difração de raios-X (DRX) e perfilometria. Foi avaliada a dureza dos revestimentos pelo ensaio de microdureza Vickers, e a aderência por ensaio de dobramento. A resistência à corrosão dos revestimentos foi avaliada por monitoramento do potencial de circuito aberto, polarização potenciodinâmica e espectroscopia de impedância eletroquímica em solução de NaCl 3,5 %. Foram obtidas curvas de coeficiente de desgaste por tempo, a partir de ensaios de desgaste a seco e em solução de NaCl 3,5 %. A partir dos resultados obtidos foi possível observar que ambos os revestimentos apresentaram uniformidade química, baixa porosidade e pouca presença de defeitos. Todos os testes eletroquímicos realizados indicaram as camadas de níquel e de cobalto como barreira, impedindo o contato do eletrólito no substrato de aço. Esse efeito foi alcançado graças à escolha correta dos parâmetros envolvidos no processo de aspersão e as características físicas dos elementos aspergidos, principalmente no que tange ao ponto de fusão que permitiu uma união eficiente entre as partículas metálicas no processo de recobrimento, gerando uma camada com poucos defeitos. O revestimento de níquel apresentou melhor desempenho frente à corrosão que o revestimento de cobalto, mas isso aconteceu devido às melhores propriedades do níquel em comparação ao cobalto. De maneira geral, ambos os revestimentos apresentarem uma melhora no desempenho do aço, contudo, o níquel mostrou-se como melhor opção de proteção ao aço API 5CT P110. / The application of thermal spray coatings applied by HVOF hypersonic flame has become an excellent solution to the challenges encountered in the oil and gas industry. This process is versatile and can be applied in components with many geometries, both in field and in the factory, enabling the repair of worn parts, preventing the complete replacement of components. Among the choices of materials that could be used, nickel and cobalt are characterized by good corrosion resistance, and low melting temperatures in relation to the operating temperatures of the HVOF process, which provides a complete fusion of the particles, producing then good quality coatings. In this context, this work aimed to obtain and characterize nickel and cobalt coatings applied by high velocity oxygen fuel (HVOF) thermal sprayed process on a API 5CT P110 steel. The morphology and microstructure of the coatings were analyzed by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), X-ray diffraction (XRD) and profilometry. The hardness of the coatings was evaluated by Vickers microhardness tests, and the adhesion of the coatings was evaluated by bending test. The corrosion resistance of the coatings was evaluated by open circuit potential monitoring, potentiodynamic polarization and electrochemical impedance spectroscopy in 3.5% NaCl solution. Wear rate by time curves were obtained from wear tests on dry and in 3.5% NaCl solution. From the results obtained it was observed that both coatings showed chemical uniformity, low porosity and almost absence of defects. All of electrochemical tests indicated the nickel and cobalt layers as a barrier, preventing the contact between the electrolyte and the steel substrate. This effect was achieved through the correct choice regarding the parameters involved in the spraying process and the physical characteristics of sprayed elements, especially with respect to the melting point which allowed an efficient binding between the metal particles in the coating process, generating a layer with few defects. The nickel coating showed better performance against corrosion than the cobalt coating, but this happened due the better properties of nickel in comparison to cobalt. In general both coatings improve the steel performance, however the nickel coating showed to be the best option regarding the API 5CT P110 steel protection.
|
Page generated in 0.0656 seconds