• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 9
  • 3
  • 2
  • 2
  • Tagged with
  • 29
  • 18
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da fase extratora polidimetilsiloxano/polipirrol nas análises de antidepressivos em amostras de plasma, através das técnicas: extração sortiva em barra de agitação e cromatografia líquida / Evaluation of the extraction polydimethylsiloxane/polypirrole phase in the antidepressants analysis in plasma samples through of the techniques: stir bar sorptive extraction and liquid chromatography

Melo, Lidervan de Paula 26 October 2007 (has links)
A monitorização terapêutica tem sido descrita como valioso recurso clínico, na individualização do regime de dosagem, de acordo com a concentração do fármaco e/ou de seus produtos de biotransformação, em amostras de plasma ou soro, coletadas com base no contexto clínico e nos princípios da farmacocinética. Em razão da complexidade dos fluidos biológicos e da baixa concentração dos fármacos nestas matrizes, a etapa de preparo de amostra, extração, pré-concentração dos analitos e eliminação dos interferentes, têm sido requerida para o desenvolvimento de métodos cromatográficos com alta sensibilidade e seletividade analítica. A extração sortiva em barra de agitação (SBSE), recente técnica de preparo de amostra, baseia-se no equilíbrio de sorção do analito entre as fases: extratora (polidimetilsiloxano) e amostra aquosa. A fase extratora PDMS é a única disponível no mercado, o que tem limitado a sensibilidade e a seletividade analítica da técnica SBSE. O uso de polipirrol (PPY) como fase extratora está relacionado às diferentes interações de seus grupos funcionais (hidrofóbica, -, com o grupo funcional polar, troca iônica, ácido-básica, dipolo-dipolo e dipolo induzido-dipolo.) com os analitos. Neste trabalho, uma nova fase extratora SBSE, com o revestimento misto PDMS/PPY foi avaliada para análises de antidepressivos em amostras de plasma, por cromatografia líquida de alta eficiência. A otimização das variáveis SBSE: tempo e temperatura de extração, tempo de dessorção e pH da matriz biológica, baseada no equilíbrio de sorção dos analitos entre as fases: polimérica (PDMS/PPY) e fluido biológico, permitiu a determinação dos analitos em concentrações plasmáticas que contemplam o intervalo terapêutico. A presença de estrutura porosa (PPY) e não porosa (PDMS) na superfície polimérica da barra extratora SBSE-PDMS/PPY foi confirmada através de análises por Microscopia Eletrônica de Varredura (MEV). De acordo, com os resultados obtidos nas análises de MEV e nas análises (individuais e simultâneas) de amostras de plasma enriquecidas com os analitos, os mecanismos de retenção dos fármacos junto à superfície PDMS/PPY ocorreram através dos processos de adsorção (PPY) e absorção (PDMS). A validação analítica foi realizada segundo as normas da Agência Nacional de Vigilância Sanitária. O método padronizado apresentou linearidade no intervalo de concentração plasmática que variou dos limites de quantificação a 500 ng mL-1, coeficientes de determinação maiores que 0,994, precisão inter ensaios com coeficientes de variação menores que 15% e exatidão de 96% a 106%. Os valores de limites de quantificação obtidos são congruentes com a menor concentração plasmática do intervalo terapêutico preconizado. O método SBSE-PDMS/PPY padronizado e validado foi utilizado para determinações dos antidepressivos, sertralina, duloxetina e fluoxetina em amostras de plasma de pacientes, em terapia com estes fármacos. Desta forma, o método SBSE-PDMS/PPY poderá ser empregado para fins de monitorização terapêutica. / Therapeutic drug monitoring has been described a valuable clinical resource for the customization of the dosage regimen, in accordance with the drug concentration and/or its biotransformation products, in of plasma or serum samples, collected on the basis of clinical context and pharmacokinetics principles. Due the complexity of biological fluids and the low concentration of the drug in these matrices, an stage of sample preparation, extraction, pre-concentration of the analytes and elimination of the interferents has been required for the development of chromatographic methods with high sensitivity and analytical selectivity. Stir bar sorptive extraction (SBSE), a recent sample preparation technique, is based on the sorption equilibrium of the analytes between the polydimethylsiloxane (PDMS) and aqueous phases. PDMS is the only commercially available extraction phase (SBSE), which has limited the analytical sensitivity and the selectivity of the SBSE technique. The use of polypyrrole (PPY) as extraction phase is related to the different interactions of its functional groups (- interactions, polar groups interactions, acid-base, dipole-dipole, dipole-induced-dipole) and the analytes. In this work, a new SBSE extraction phase, with a PDMS/PPY coating was evaluated for the analysis of antidepressants in plasma samples by High Performance Liquid Chromatography. The optimization of the SBSE variables extraction time and temperature, dessorption time and pH of the biological matrix based on the sorption equilibrium of the analytes between the polymeric (PDMS/PPY) and biological fluid phases, allowed determination of the analytes in plasmatic concentrations that correspond to the therapeutic interval. The presence of a porous structure (PPY) as well as no none, porous (PDMS), on the polymeric surface of SBSE-PDMS/PPY was confirmed by Scanning Electron Microscopy (SEM) analyses. In agreement with the results obtained by SEM analyses and individual and simultaneous analyses of the plasma samples spiked with the analytes, the mechanisms of drugs retention on the surface of PDMS/PPY occur through adsorption (PPY) and absorption (PDMS). Analytical validation was carried through according to the norms of the National Agency of Sanitary Vigilance. The standardized method presented linearity in the plasmatic interval concentrations that varied from the limits of quantification to 500 ng mL-1, the determination coefficients were higher than 0.994, inter precision assays with coefficients of variation lower than 15%, and accuracy from 96% to 106%. The quantification value limits were in agreement with the lowest plasmatic concentration of the established therapeutical interval. The standardized and validated SBSE-PDMS/PPY method was used for determination of sertraline, duloxetine and fluoxetine in plasma patient samples under therapy with these drugs. Thus, the SBSE-PDMS/PPY method could be used for therapeutic drug monitoring.
2

Avaliação da fase extratora polidimetilsiloxano/polipirrol nas análises de antidepressivos em amostras de plasma, através das técnicas: extração sortiva em barra de agitação e cromatografia líquida / Evaluation of the extraction polydimethylsiloxane/polypirrole phase in the antidepressants analysis in plasma samples through of the techniques: stir bar sorptive extraction and liquid chromatography

Lidervan de Paula Melo 26 October 2007 (has links)
A monitorização terapêutica tem sido descrita como valioso recurso clínico, na individualização do regime de dosagem, de acordo com a concentração do fármaco e/ou de seus produtos de biotransformação, em amostras de plasma ou soro, coletadas com base no contexto clínico e nos princípios da farmacocinética. Em razão da complexidade dos fluidos biológicos e da baixa concentração dos fármacos nestas matrizes, a etapa de preparo de amostra, extração, pré-concentração dos analitos e eliminação dos interferentes, têm sido requerida para o desenvolvimento de métodos cromatográficos com alta sensibilidade e seletividade analítica. A extração sortiva em barra de agitação (SBSE), recente técnica de preparo de amostra, baseia-se no equilíbrio de sorção do analito entre as fases: extratora (polidimetilsiloxano) e amostra aquosa. A fase extratora PDMS é a única disponível no mercado, o que tem limitado a sensibilidade e a seletividade analítica da técnica SBSE. O uso de polipirrol (PPY) como fase extratora está relacionado às diferentes interações de seus grupos funcionais (hidrofóbica, -, com o grupo funcional polar, troca iônica, ácido-básica, dipolo-dipolo e dipolo induzido-dipolo.) com os analitos. Neste trabalho, uma nova fase extratora SBSE, com o revestimento misto PDMS/PPY foi avaliada para análises de antidepressivos em amostras de plasma, por cromatografia líquida de alta eficiência. A otimização das variáveis SBSE: tempo e temperatura de extração, tempo de dessorção e pH da matriz biológica, baseada no equilíbrio de sorção dos analitos entre as fases: polimérica (PDMS/PPY) e fluido biológico, permitiu a determinação dos analitos em concentrações plasmáticas que contemplam o intervalo terapêutico. A presença de estrutura porosa (PPY) e não porosa (PDMS) na superfície polimérica da barra extratora SBSE-PDMS/PPY foi confirmada através de análises por Microscopia Eletrônica de Varredura (MEV). De acordo, com os resultados obtidos nas análises de MEV e nas análises (individuais e simultâneas) de amostras de plasma enriquecidas com os analitos, os mecanismos de retenção dos fármacos junto à superfície PDMS/PPY ocorreram através dos processos de adsorção (PPY) e absorção (PDMS). A validação analítica foi realizada segundo as normas da Agência Nacional de Vigilância Sanitária. O método padronizado apresentou linearidade no intervalo de concentração plasmática que variou dos limites de quantificação a 500 ng mL-1, coeficientes de determinação maiores que 0,994, precisão inter ensaios com coeficientes de variação menores que 15% e exatidão de 96% a 106%. Os valores de limites de quantificação obtidos são congruentes com a menor concentração plasmática do intervalo terapêutico preconizado. O método SBSE-PDMS/PPY padronizado e validado foi utilizado para determinações dos antidepressivos, sertralina, duloxetina e fluoxetina em amostras de plasma de pacientes, em terapia com estes fármacos. Desta forma, o método SBSE-PDMS/PPY poderá ser empregado para fins de monitorização terapêutica. / Therapeutic drug monitoring has been described a valuable clinical resource for the customization of the dosage regimen, in accordance with the drug concentration and/or its biotransformation products, in of plasma or serum samples, collected on the basis of clinical context and pharmacokinetics principles. Due the complexity of biological fluids and the low concentration of the drug in these matrices, an stage of sample preparation, extraction, pre-concentration of the analytes and elimination of the interferents has been required for the development of chromatographic methods with high sensitivity and analytical selectivity. Stir bar sorptive extraction (SBSE), a recent sample preparation technique, is based on the sorption equilibrium of the analytes between the polydimethylsiloxane (PDMS) and aqueous phases. PDMS is the only commercially available extraction phase (SBSE), which has limited the analytical sensitivity and the selectivity of the SBSE technique. The use of polypyrrole (PPY) as extraction phase is related to the different interactions of its functional groups (- interactions, polar groups interactions, acid-base, dipole-dipole, dipole-induced-dipole) and the analytes. In this work, a new SBSE extraction phase, with a PDMS/PPY coating was evaluated for the analysis of antidepressants in plasma samples by High Performance Liquid Chromatography. The optimization of the SBSE variables extraction time and temperature, dessorption time and pH of the biological matrix based on the sorption equilibrium of the analytes between the polymeric (PDMS/PPY) and biological fluid phases, allowed determination of the analytes in plasmatic concentrations that correspond to the therapeutic interval. The presence of a porous structure (PPY) as well as no none, porous (PDMS), on the polymeric surface of SBSE-PDMS/PPY was confirmed by Scanning Electron Microscopy (SEM) analyses. In agreement with the results obtained by SEM analyses and individual and simultaneous analyses of the plasma samples spiked with the analytes, the mechanisms of drugs retention on the surface of PDMS/PPY occur through adsorption (PPY) and absorption (PDMS). Analytical validation was carried through according to the norms of the National Agency of Sanitary Vigilance. The standardized method presented linearity in the plasmatic interval concentrations that varied from the limits of quantification to 500 ng mL-1, the determination coefficients were higher than 0.994, inter precision assays with coefficients of variation lower than 15%, and accuracy from 96% to 106%. The quantification value limits were in agreement with the lowest plasmatic concentration of the established therapeutical interval. The standardized and validated SBSE-PDMS/PPY method was used for determination of sertraline, duloxetine and fluoxetine in plasma patient samples under therapy with these drugs. Thus, the SBSE-PDMS/PPY method could be used for therapeutic drug monitoring.
3

Preparation and Application of Conducting Polymer-Carbon Nanotube Composite.

Oh, Jungmin 18 December 2004 (has links)
Recently there have been considerable interests in nanometerial study. In this work, we have used carbon nanotubes (CNTs) and polypyrrole (PPy) conducting polymers (CPs) as models to make a nanotube and conducting polymer composite material. Under electro-oxidation condition, the PPy/CNT films can be grown on conventional substrates such as a glassy carbon electrode in aqueous and non-aqueous media. These nano-conjugated materials are based on the doping of CNTs particles into conducting polymer network while oxidatively polymerizing. CNTs serve as dopants and solely supporting electrolytes in the preparation. The CP/CNT new composite materials have showed promise not only in a potential environmental remedy such as conversion of highly toxic Cr(VI) into less harmful Cr(III), but also in electrocatalysis of the quinone/hydroquinone redox reaction. Voltammetry, bulk electrolysis with coulometry, AC impedance, and EQCM techniques have been used to elucidate the preparation, ion transport, and intermolecular interaction processes within these composites.
4

Structural Analysis Of Polyaniline-polypyrrole Copolymers Via Pyrolysis Mass Spectrometry

Tezal, Feride 01 February 2007 (has links) (PDF)
This thesis describes recent progress in electrochemical preparation of several conducting polymers. In particular, the synthesis and characterizations of pure polyaniline, pure polypyrrole, polyaniline/polypyrrole and polypyrrole/polyaniline copolymers and polyaniline-polypyrrole physical blends were studied. The focus has included firstly synthesis of these electrically conductive polymers. Secondly, thermal characteristics of electrochemically synthesized homopoly- mers, copolymers and their physical blends were investigated by thermal gravi- metric analysis (TGA), differential scanning calorimetry (DSC) and direct pyrol- ysis mass spectrometry (DIP-MS) techniques. In general, TGA analysis showed three-step thermal degradation. The first, at 100oC, was attributed to water, and unreacted monomers. The second weight losses observed at around 150 oC was because of evolution of water and/or acid. Finally, the removal of the dopant ion and low molecular weight species from the matrix were observed for pure PANI and pure PPy at 230 and 280 oC, respectively. PANI/PPy films and PPy/PANI films have decomposition temperatures at 272oC because of the loss of the dopant ion. It was also observed that pure PPy was thermally more resistant than pure PANI. Thirdly, thermal characteristics, and degradation products of electrochemi- cally prepared PANI/PPy and PPy/PANI films in solutions containing variable dopant (SO42&amp / #8722 / ) concentrations were analyzed and compared with pyrolysis mass spectrometry. Similar to TGA study, there were three main thermal degradation steps namely, evolution of low molecular weight species, dopant based products and degradation products of polymers. The dopant concentration was monitored to optimize the degradation behavior. Pyrolysis mass spectrometry data showed that the degree of degradation of the polymer already coated on the electrode enhanced as the dopant concentration used in synthesis increased.
5

Síntese e caracterização de polipirrol (PPy) obtido pelo processo químico convencional e microemulsão

Santim, Ricardo Hidalgo [UNESP] 18 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-18Bitstream added on 2014-06-13T18:28:58Z : No. of bitstreams: 1 santim_rh_me_ilha.pdf: 3013361 bytes, checksum: 9c0ba8507c697ecca7db1980615ec2b6 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os polímeros são muito conhecidos por serem materiais de fácil processamento, leveza, isolantes elétricos e até mesmo térmicos. Essas propriedades viabilizaram várias aplicações tecnológicas desde utensílios domésticos à indústria. No fim do século passado as pesquisas voltaram-se em busca de energias renováveis e novos materiais que associassem as vantagens dos polímeros com as propriedades elétricas dos metais. Com essas pesquisas surgiu uma nova classe de polímeros chamada de Polímeros Condutores Intrínsecos (PCIs) que dispõem de boas propriedades de condução elétrica inerente ao material. Esses PCIs podem ser sintetizados em forma de fibras ou filmes, sozinhos ou com vários outros polímeros para formar blendas com diferentes propriedades. O polipirrol (PPy) é um PCI que proporciona altas condutividades elétricas e boa estabilidade oxidativa, algo difícil de se conseguir com essa classe de polímeros. Esse trabalho teve como objetivo sintetizar amostras de PPy por dois métodos de síntese química: convencional (em solução aquosa) e microemulsão com dodecil sulfato de sódio (SDS – surfactante e dopante). No primeiro método foi variada a razão molar de monômero/oxidante e no segundo variou-se as razões molares de monômero/oxidante/dopante. Para o estudo dessas amostras foram realizadas análises estruturais, morfológicas, térmicas, ópticas e elétricas. De maneira geral, as amostras que apresentaram melhores características morfológicas, ópticas e de condutividade elétrica, foram as obtidas no processo químico em microemulsão, de tal maneira que, quanto maior a quantidade de SDS e menor a temperatura, menor foi o tamanho das partículas de PPy, maior a conjugação das cadeias e maior a dopagem com SDS. / The polymers are known to be materials easy processed, slight, electrical insulators and even heat. These properties made possible many technological applications, from household items to the industry. At the end of last century the polls turned in search of renewable energy and new materials that combines the benefits of polymers with the electrical properties of metals. With these studies emerged a new class of polymers called Intrinsic Conducting Polymers (PICs) that have good electrical conduction properties inherent to the material. These PICs can be synthesized in the form of fibers or films, either alone or with various other polymers to form blends with different properties. The polypyrrole (PPy) is a PIC that provides high electrical conductivity and good oxidative stability, something difficult to achieve with this class of polymers. This study aimed to synthesize PPy samples by two methods of chemical synthesis: conventional (aqueous solution) and microemulsion SDS (dodecilsulfate of sodium – surfactant and dopant). In the first method was varied the molar ratio of monomer/oxidant and the second was varied molar ratios of monomer/oxidant/dopant. For the study of these samples were performed structural analyses, morphological, thermal, optical and electrical. In general, samples that showed better morphological characteristics, optical and electrical conductivity were obtained in the chemical process of microemulsion, such a way that the larger the amount of SDS and the lower the temperature, the smaller the particle size of PPy, the greater the conjugation of chains and the higher the doping with SDS.
6

Influência do contra-íon usado na eletrossíntese do polipirrol em sua resposta como biossensor eletroquímico após a imobilização da polifenol oxidase / Influence of counter-ion used in the electrosynthesis of polypyrrole in your response as electrochemical biosensors after polyphenol oxidase immobilization

Barioto, Valquiria da Cruz Rodrigues 16 July 2009 (has links)
Neste trabalho, foram fabricados biossensores amperométricos a partir do uso da polifenol oxidase (PFO), obtida do abacate como fonte enzimática, imobilizada em filmes de polipirrol (PPI) e que foram eletrossintetizados em meio de três diferentes eletrólitos de suporte (NaCl e NaClO4 e NaDDS). O método de imobilização enzimática foi o da adsorção, sendo a solução de enzima adicionada à solução com o pirrol e o eletrólito durante o processo de eletropolimerização. Os filmes de PPI/PFO foram caracterizados por técnicas eletroquímicas, principalmente por voltametria cíclica. A detecção de compostos fenólicos (catecol e pirogalol) foi realizada pela técnica de cronoamperometria após se variar a concentração do analito. A morfologia dos filmes foi estudada por microscopia de força atômica (AFM), sendo observado que a presença da enzima no filme polimérico assim como o uso de diferentes eletrólitos de suporte levou a diferenças na superfície dos filmes. Além disto, verificou-se que o biossensor construído a partir do uso do NaCl, apresentava uma resposta mais eficiente, ou seja, ele foi capaz de detectar catecol e pirogalol em um menor limite de detecção. / In this study amperometric biosensors were manufactured from the use of polyphenol oxidase (PPO) obtained from avocado as a source of enzyme immobilized in polypyrrole (PPY) films that were electrosynthesized with three different support electrolytes (NaCl, NaClO4 and NaDDS). The method of enzyme immobilization was the adsorption. The PPO was added in the solution containing pyrrole and electrolyte during electropolymerization. The PPY/PPO films were characterized by electrochemical techniques mainly by cyclic voltammetry. Detection of phenolic compounds (catechol and pyrogallol) was performed by the technique of chronoamperometry after varying the concentration of the analyte. The morphology of the films was studied by the atomic force microscopy (AFM) and observed that the presence of the enzyme in the polymer film and the use of different electrolytes support led to differences in the surface of films. However it was found that the biosensor constructed from the use of NaCl showed more efficient response and it was able to detect catechol and pyrogallol in a lower limit of detection.
7

Sistemas poliméricos semicondutores para aplicação como camada ativa em LED. / Polymer semiconductors systems for application as active layer in led.

Oide, Mariane Yuka Tsubaki 07 February 2019 (has links)
Diodos poliméricos emissores de luz (PLEDs) foram produzidos utilizando poli(vinil-carbazol) (PVK), poli(2,7-(9,9-dioctilfluoreno)) (PFO) e poli((1,4-fenileno-2-flúor)-alt-2,7-(9,9-dioctilfluoreno)) (PFPF) dopados com diferentes concentrações de dopante fosforescente tris(2-fenilpiridinato) de irídio(III) [Ir(ppy)3] como camada ativa. Os resultados mostraram que o dispositivo a base de PFO dopado com 4% em massa de Ir(ppy)3 apresentou as maiores eficiências de corrente e de potência luminosa e o espectro eletromagnético do PLED a base de PVK puro apresentou emissão em 540 nm, sugerindo um desbalanceamento de cargas e emissão do óxido de zinco dopado com alumínio (AZO), camada injetora. Assim, estudos da influência da massa molar média do PVK e de sistemas híbridos PVK:AZO nas propriedades elétricas e ópticas dos PLEDs foram elaborados. Resultados mostraram que o AZO possui propriedades foto/eletroluminescentes e é responsável pela emissão larga na região do visível. Os dispositivos híbridos apresentaram emissão próxima ao branco puro, atingindo-se uma pureza de 0,19. / Polymer light emiting diodes (PLEDs) were manufactured using poly(9-vinylcarbazole) (PVK), poly(9,9-dioctylfluorene) (PFO) and poly(9,9-dioctylfluorene-alt-1,4-fluorphenylene) (PFPF) doped with different concentrations of tris-(2-phenylpyridinate) iridium(III) [Ir(ppy)3],a phosphorescent dye, as the active layer. Results showed that PFO based devices doped with 4 wt. % of Ir(ppy)3 presented the highest current and power efficiencies, and the PVK based devices\' electroluminescence spectrum showed an emission centered at 540 nm, suggesting that a charge unbalance and light emission from the injection layer of aluminum doped zinc oxide (AZO) occurred. Therefore, studies based on the PVK:AZO system and different PVK\'s average molar masses were elaborated to observe the PLEDs\' electrical and optical properties. Results showed that AZO is a photo/electroluminescent material and it is responsible for the broad emission in the visible range. The hybrid device showed near pure white light emission and its purity reached 0.19.
8

Estudos sobre a imobilização da polifenoloxidase em filmes de polipirrol/poli-3-metiltiofeno e uso destes filmes em biossensores amperométricos / Studies on the immobilization of polyphenoloxidase polypyrrole/poly-3-methylthiophene films and their use in amperometric biosensors

Sousa, Lívia Maria de Castro 07 June 2013 (has links)
Nesta dissertação, foram estudados os métodos de síntese de filmes poliméricos como matrizes hospedeiras da enzima tirosinase vislumbrando o desenvolvimento de biossensores mais seletivos e duradouros na detecção de compostos fenólicos. Os polímeros utilizados e preparados por cronoamperometria em acetonitrila foram: polipirrol (PPI), polimetiltiofeno (PMET) e copolímero PPI-PMET. Os filmes PPI-PMET apresentaram características intermediárias às dos filmes PPI e PMET, conforme se verificaram em espectros na região do infravermelho (FTIR), voltametria cíclica e microscopia de força atômica (AFM), evidenciando, assim, a formação de uma nova matriz polimérica. O processo de superoxidação do filme PPI-PMET foi estudado visando a uma imobilização mais eficiente da enzima, quando se obteve uma condição na qual a superoxidação ocorre somente nas cadeias de PPI. Biossensores amperométricos foram preparados a partir do uso da tirosinase extraída do abacate como fonte enzimática por imobilização física e realizada de maneiras diferentes em filmes não superoxidados e superoxidados. Foi feita a otimização das respostas dos filmes variando-se o pH, potencial de trabalho, concentração da enzima e tempo de imobilização da enzima para a detecção de catecol. Os resultados indicaram que a superoxidação do PPI nos filmes PPI-PMET favoreceu a imobilização da enzima, embora não fosse tão eficiente quando se comparou aos filmes com o PPI não superoxidado. Contudo, os biossensores, em geral, apresentaram grande sensibilidade ao catecol, com um limite de detecção baixo, da ordem de 0,12 µmol/L. / The synthesis methods of polymer films as host matrices of the enzyme tyrosinase were studied in this dissertation. It was expected the development of selective and everlasting biosensors for the detection of phenolic compounds. The used polymers were prepared by chronoamperometry in acetonitrile as followed: polypyrrole (PPI), polymethylthiophene (PMET) and copolymer PPI-PMET. The PPI-PMET films showed intermediate characteristics as the PPI and PMET films, as observed in the infrared spectra (FTIR), cyclic voltammetry and atomic force microscopy (AFM), thus indicating the formation of a new polymeric matrix . The process of overoxidized of PPI-PMET film was studied in order to achieve a more efficient immobilization of the enzyme, whilst it was achieved a condition in which overoxidized occurs only in the PPI chain. Amperometric biosensors were prepared from the use of tyrosinase extracted from avocado as an enzyme source by physical immobilization and performed in different ways in both overoxidized and non-overoxidized films. It was performed the optimization of the responses of the films by varying pH, operacuonial potential, enzyme concentration and time in the enzyme immobilization for the detection of catechol. The results showed that the overoxidized PPI in the films PPI-PMET favored the immobilization of the enzyme, although not as efficient when compared to the films with nom overoxidized PPI. Neverthless, the catechol biosensors showed a high sensitivity with a low detection limit in the order of 0.12 µmol/L.
9

Filmes de polipirrol como matrizes para a imobilização da polifenol oxidase e aplicação como biossensores amperométricos na análise de compostos fenólicos / Polypyrrole film as matrix for the immobilization of polyphenol oxidase and application as amperometric biosensors in the analysis of phenolic

Ferreira, Elys Raquel Andrade 14 December 2007 (has links)
Nesta dissertação, a polifenol oxidase (PFO) como extrato bruto de abacate (Persea americana) foi imobilizada em filmes de polipirrol (PPI) sintetizados eletroquimicamente utilizando o glutaraldeído (GA) como um agente de ligação entrecruzada. Os filmes PPI e PPI/PFO-GA foram caracterizados por eletroquímica, principalmente voltametria cíclica, sendo avaliadas a eletroatividade e a reversibilidade eletroquímica. A detecção de compostos fenólicos em soluções padrão foi feita por cronoamperometria, tendo um controle sobre a concentração dos compostos. O processo de transferência de massa foi monitorado com uma microbalança de cristal de quartzo eletroquímica. Os resultados indicaram uma boa reprodutibilidade das medidas na detecção dos compostos fenólicos. A estabilidade do biossensor em uma solução tampão manteve-se durante 27 dias, um resultado aceitável já que é encontrado na literatura um tempo de vida estável para sistemas semelhantes em tomo de 30 dias / In this dissertation, polyphenol oxidase (PPO) as crude extract of avocado (Persea americana) was immobilized on electrochemical1y synthesized polypyrrole (PPY) films using glutaraldehyde (GA) as a crosslinking agent. PPY and PPY/PPO-GA films were electrochemical1y characterized, mainly by cyclic voltametry, where electroactivity and electrochemical reversibility were evaluated. The detection of phenolic compounds in standard samples was made by chronoamperometry with a control over the compound concentration. The process of mass transfer was monitored with an electrochemical quartz crystal microbalance (EQCM). Our results indicated a good repeatability of the measurements for the detection of phenolic compounds. The stability of biosensor in a buffer solution has remained for 27 days, a result acceptable since it is found in the literature a time of life stable for similar systems around 30 days
10

Conductive Nanocrystalline Cellulose Polymer Composite Film as a Novel Mediator in Biosensor Applications

Lee, Andrew Dong-Hyun 14 December 2011 (has links)
Recent biosensors using glucose oxidase enzyme to detect glucose (“blood sugar”) were made with intrinsic conducting polymers such as poly pyrrole (PPY) to mediate the reaction. PPY coated electrodes were difficult to employ via eletropolymerization because PPY is only soluble in solvents potentially damaging to enzymes. Nano crystalline cellulose – poly pyrrole (NCC-PPY) colloid circumvents this by forming natural, enzyme compatible, and hydrophilic films mechanically bound to electrodes using easy-to-disperse colloids. NCC-PPY was studied as mediator to investigate use in biosensor applications. Using NCC-PPY film casted on microfabricated interdigitated electrodes, a glucose biosensor with sensitivity factor of 20 was achieved. NCC-PPY showed enhanced catalysis with no enzyme inactivation and a total current of 2mA. Enhanced sensitivity was attributed to resistance changes of doped PPY, redox mediation, and compatibility of cellulose with enzyme.

Page generated in 0.0309 seconds