RF compression of electron bunches applied to ultrafast electron diffractionChatelain, Robert P., 1982- January 2008 (has links)
The dynamics of atomic scale structures during structural change can be studied by Ultrafast Electron Diffraction (UED). The time resolution needed to reveal the fastest dynamics is 100 fs. Sub-angstrom structural resolution becomes possible with 1-1000 pC of charge necessary for diffraction pattern analysis during subtle structural changes. This combination of requirements cannot currently be realized due to the space-charge temporal broadening inherent to bunches of electrons of high fluence and short temporal duration. Simulations show that the incorporation of a specially designed Radio-Frequncy (RF) cavity into the UED apparatus removes this technical limitation. The RF cavity reverses the near linear position-momentum distribution of the temporally broadened electron bunch, causing the bunch to recompress itself as it propagates. It is found that our proposed method allows for sub-100 fs bunches with maximum charge of 0.6 pC, almost 3 orders of magnitude improvement over today's state of the art.
|
22 |
Measuring the spatiotemporal electric field of ultrashort pulses with high spatial and spectral resolutionBowlan, Pamela 06 April 2009 (has links)
In this thesis a powerful and practical method for characterizing ultrashort pulses in space and time is described (called SEA TADPOLE). First we focus on measuring pulses that are spatially uniform but very complicated in time or frequency. We demonstrate and verify that SEA TADPOLE can measure temporal features as small as 30 femtoseconds over durations as long as
14 picoseconds. The spectral resolution of this device is carefully studied and we demonstrate that for certain pulses, we achieve spectral super resolution. We also develop and test an algorithm for measuring polarization shaped pulses with SEA TADPOLE. Our simple interferometer can even be used to measure
the spatiotemporal electric field of ultrashort pulses at a focus. This is because SEA TADPOLE samples the field with an optical fiber which has a small core size. Therefore this fiber can be used to spatially sample the beam, so that the temporal electric field can be measured at every position to obtain E(x, y, z, t). The single mode
fiber can be replaced with an NSOM (Near Field Scanning Optical Microscopy) fiber so that spatial resolution as low as 500nm (and possibly lower) can be achieved. Using
this device we make the first direct measurements of the compete field of focusing
ultrashort pulses. These measurement can be viewed as "snap shots" in flight of the focusing pulse. Also, for the first time, we have observed some of the interesting distortions that have been predicted for focusing ultrashort pulses such as the "forerunner" pulse, radially varying group delay dispersion, and the Bessel-like X-shaped pulse. We have also made the first direct measurements of the electric field of Bessel X-pulses and their propagation invariance is demonstrated. We also use SEA TADPOLE to study the "boundary wave pulses" which are due to diffraction.
|
23 |
Ultrafast studies of reactive intermediatesWang, Jin, January 2007 (has links)
Thesis (Ph. D.)--Ohio State University, 2007. / Title from first page of PDF file. Includes bibliographical references (p. 440-459).
|
24 |
Picosecond Laser-Induced Transient Gratings and Anisotropic State-Filling in GermaniumBoggess, Thomas F. (Thomas Frederick) 12 1900 (has links)
We present a comparative theoretical study of the transient grating coherent effects in resonant picosecond excitation-probe experiments. Signals in both the probe and conjugate directions are discussed. The effects of recombination, non-radiative scattering and spatial and orientational diffusion are included. The analysis is applied to both a molecular and to a semiconductor model. Signal contributions from concentration and orientational gratings are distinguished and their temporal natures discussed. The theory is used to explain our recent observations in germanium. Included are discussions of picosecond transient grating self-diffraction measurements that can be understood in terms of an orientational grating produced by anisotropic (in k-space) state-filling. Though there have been predictions and indirect experimental evidence for isotropic state-filling in germanium, this is the first direct experimental indication of anisotropic state-filling in a semiconductor.
|
25 |
RF compression of electron bunches applied to ultrafast electron diffractionChatelain, Robert P., 1982- January 2008 (has links)
No description available.
|
26 |
Measuring the electric field of picosecond to nanosecond pulses with high spectral resolution and high temporal resolutionCohen, Jacob Arthur 08 October 2010 (has links)
We demonstrate four experimentally simple methods for measuring very complex ultrashort light pulses. Although each method is comprised of only a few optical elements, they permit the measurement of extremely complex pulses with time-bandwidth products greater than 65,000. First, we demonstrate an extremely simple frequency-resolved-optical gating (GRENOUILLE) device for measuring the intensity and phase of pulses up to ~20ps in length. In order to achieve the required high spectral resolution and large temporal range, it uses a few-cm-thick second harmonic-generation crystal in the shape of a pentagon. This has the additional advantage of reducing the device's total number of components to three. Secondly, we introduce a variation of spectral interferometry (SI) using a virtually imaged phased array and grating spectrometer for measuring long complex ultrashort pulses up to 80 ps in length. Next, we introduce a SI technique for measuring the complete intensity and phase of relatively long and very complex ultrashort pulses. It involves making multiple measurements using SI (in its SEA TADPOLE variation) at numerous delays, measuring many temporal pulselets within the pulse, and concatenating the resulting pulselets. Its spectral resolution is the inverse delay range--many times higher than that of the spectrometer used. The waveforms were measured with ~ fs temporal resolution over a temporal range of ~ns and had time-bandwidth products exceeding 65,000, which to our knowledge is the largest time-bandwidth product ever measured with ~fs temporal resolution. Finally, we demonstrate a single-shot measurement technique that temporally interleaves hundreds of measurements with ~fs temporal resolution. It is another variation of SI for measuring the complete intensity and phase of relatively long and complex ultrashort pulses in a single shot. It uses a grating to introduce a transverse time delay into a reference pulse which gates the unknown pulse by interfering it at the image plane of an imaging spectrometer. It provided ~125 fs temporal resolution and a temporal range of 70 ps using a low-resolution spectrometer.
|
27 |
Ultrasonic Pulse Wave Imaging for in vivo Assessment of Vascular Wall Dynamics and Characterization of Arterial PathologiesLi, Ronny Xi January 2016 (has links)
Arterial diseases such as hypertension, carotid stenosis, and abdominal aortic aneurysm (AAA) may progress silently without symptoms and contribute to acute cardiovascular events such as heart attack, stroke, and aneurysm rupture, which are consistently among the leading causes of death worldwide. The arterial pulse wave, regarded as one of the fundamental vital signs of clinical medicine, originates from the heart and propagates throughout the arterial tree as a pressure, flow velocity, and wall displacement wave, giving rise to the natural pulsation of the arteries. The dynamic properties of the pulse wave are intimately related to the physical state of the cardiovascular system. Thus, the assessment of the arterial wall dynamics driven by the pulse wave may provide valuable insights into vascular mechanical properties for the early detection and characterization of arterial pathologies.
The focus of this dissertation was to develop and clinically implement Pulse Wave Imaging (PWI), an ultrasound elasticity imaging-based method for the visualization and spatio-temporal mapping of the pulse wave propagation at any accessible arterial location. Motion estimation algorithms based on cross-correlation of the ultrasound radio-frequency (RF) signals were used to track the arterial walls and capture the pulse wave-induced displacements over the cardiac cycle. PWI facilitates the image-guided measurement of clinically relevant pulse wave features such as propagation speed (pulse wave velocity, or PWV), uniformity, and morphology as well as derivation of the pulse pressure waveform.
A parametric study investigating the performance of PWI in two canine aortas ex vivo and 10 normal, healthy human arteries in vivo established the optimal image acquisition and signal processing parameters for reliable measurement of the PWV and wave propagation uniformity. Using this framework, three separate clinical feasibility studies were conducted in patients diagnosed with hypertension, AAA, and carotid stenosis.
In a pilot study comparing hypertensive and aneurysmal abdominal aortas with normal controls, the AAA group exhibited significantly higher PWV and lower wave propagation uniformity. A “teetering” motion upon pulse wave arrival was detected in the smaller aneurysms (< 5 cm in diameter) but not in the larger aneurysms (> 5.5 cm in diameter). While no significant difference in PWV or propagation uniformity was observed between normal and hypertensive aortas, qualitative differences in the pulse wave morphology along the imaged aortic segment may be an indicator of increased wave reflection caused by elevated blood pressure and/or arterial stiffness.
Pulse Wave Ultrasound Manometry (PWUM) was introduced as an extension of the PWI method for the derivation of the pulse pressure (PP) waveform in large central arteries. A feasibility study in 5 normotensive, 9 pre-hypertensive, and 5 hypertensive subjects indicated that a significantly higher PP in the hypertensive group was detected in the abdominal aorta by PWUM but not in the peripheral arteries by alternative devices (i.e. a radial applanation tonometer and the brachial sphygmomanometer cuff). A relatively strong positive correlation between aortic PP and both radial and brachial PP was observed in the hypertensive group but not in the normal and pre-hypertensive groups, confirming the notion that PP variation throughout the arterial tree may not be uniform in relatively compliant arteries.
The application of PWI in 10 stenotic carotid arteries identified phenomenon such as wave convergence, elevated PWV, and decreased cumulative displacement around and/or within regions of atherosclerotic plaque. Intra-plaque mapping of the PWV and cumulative strain demonstrated the potential to quantitatively differentiate stable (i.e. calcified) and vulnerable (i.e. lipid) plaque components. The lack of correlation between quantitative measurements (PWV, modulus, displacement, and strain) and expected plaque stiffness illuminates to need to consider several physiological and imaging-related factors such as turbulent flow, wave reflection, imaging location, and the applicability of established theoretical models in vivo.
PWI presents a highly translational method for visualization of the arterial pulse wave and the image-guided measurement of several clinically relevant pulse wave features. The aforementioned findings collectively demonstrated the potential of PWI to detect, diagnose, and characterize vascular disease based on qualitative and quantitative information about arterial wall dynamics under pathological conditions.
|
28 |
Ultrafast Exciton Dynamics at Molecular SurfacesMonahan, Nicholas R. January 2015 (has links)
Further improvements to device performance are necessary to make solar energy conversion a compelling alternative to fossil fuels. Singlet exciton fission and charge separation are two processes that can heavily influence the power conversion efficiency of a solar cell. During exciton fission one singlet excitation converts into two triplet excitons, potentially doubling the photocurrent generated by higher energy photons. There is significant discord over the singlet fission mechanism and of particular interest is whether the process involves a multiexciton intermediate state. I used time-resolved two-photon photoemission to investigate singlet fission in hexacene thin films, a model system with strong electronic coupling. My results indicate that a multiexciton state forms within 40 fs of photoexcitation and loses singlet character on a 280 fs timescale, creating two triplet excitons. This is concordant with the transient absorption spectra of hexacene single crystals and definitively proves that exciton fission in hexacene proceeds through a multiexciton state. This state is likely common to all strongly-coupled systems and my results suggest that a reassessment of the generally-accepted singlet fission mechanism is required. Charge separation is the process of splitting neutral excitons into carriers that occurs at donor-acceptor heterojunctions in organic solar cells. Although this process is essential for device functionality, there are few compelling explanations for why it is highly efficient in certain organic photovoltaic systems. To investigate the charge separation process, I used the model system of charge transfer excitons at hexacene surfaces and time-resolved two-photon photoemission. Charge transfer excitons with sufficient energy spontaneously delocalize, growing from about 14 nm to over 50 nm within 200 fs. Entropy drives this delocalization, as the density of states within the Coulomb potential increases significantly with energy. This charge separation mechanism should occur at all donor-acceptor interfaces. My results show that entropy facilitates charge separation and indicate that the density of acceptor states should be a design consideration when constructing organic solar cells.
|
29 |
Picosecond Spectroscopy of Rhodamine BClark, James Burton 12 1900 (has links)
A series of picosecond excite-probe experiments was performed on various concentrations of aqueous and ethanolic solutions of rhodamine B in order to determine the existence of dimerization in those solutions. The goals of the research presented in this dissertation were twofold. Initially, various techniques of time-resolved spectroscopy were to be employed to further characterize the ground and excited-state molecular properties of the aqueous RB dimer. The information obtained, and the techniques developed in that study would then be utilized in an effort to secure evidence which would support or refute the claims of rhodamine B dimerization in an ethanolic solution.
|
30 |
Ultrafast dynamics in InAs quantum dot and GaInNAs quantum well semiconductor heterostructuresMalins, David B. January 2008 (has links)
The quantum confined Stark effect (QCSE) and ultrafast absorption dynamics near the bandedge have been investigated in p-i-n waveguides comprising quantum confined heterostructures grown on GaAs substrates, for emission at 1.3um. The materials are; isolated InAs/InGaAs dot-in-a-well (DWELL) quantum dots (QD), bilayer InAs quantum dots and GaInNAs multiple quantum wells (MQW). The focus was to investigate these dynamics in a planar waveguide geometry, for the purpose of large scale integration in optical systems. Initial measurements of the QCSE using photocurrent measurements showed a small shift for isolated QDs whilst a significant shift of 40nm (at 1340nm) was demonstrated for bilayer dots, comparable to that of GaInNAs MWQ (30nm at 1300nm). These are comparable to InP based quaternary multiple quantum wells used in modulator devices. With the use of a broadband continuum source the isolated quantum dots exhibit both a small QCSE (15nm at 1280nm) and minimal broadening which is desirable for saturable absorbers used in monolithic modelocked semiconductor lasers (MMSL). A robust experimental set-up was developed for characterising waveguide modulators whilst the electroabsorption and electro-refraction was calculated (dn=1.5x10⠻³) using the Kramers-Kronig dispersion relation. Pump probe measurements were performed at room temperature using 250fs pulses from an optical parametric oscillator (OPO) on the three waveguide samples. For the isolated QDs ultrafast absorption recovery was recorded from 62ps (0V) to 700fs (-10V and the shortest times shown to be due to tunneling. Additionally we have shown good agreement of the temperature dependence of these dots and the pulse width durations from a modelocked semiconductor laser using the same material. Bilayer QDs are shown to exhibit ultrafast absorption recovery from 119ps (0V) to 5ps (-10V) offering potential for applications as modelocking elements. The GaInNAs multiple quantum wells show absorption recovery of 55ps (0V), however under applied reverse bias they exhibit long lived field screening transients. These results are explained qualitatively by the spatial separation of electrons and holes at heterobarrier interfaces.
|