Spelling suggestions: "subject:"polímeros como compressão molecular"" "subject:"límeros como compressão molecular""
1 |
Estratégias computacionais para escolha de monômeros para síntese de polímeros molecularmente impressos (MIPs) / Computational strategies for monomers selection for the synthesis of molecularly imprinted polymers (MIPs)Moura, Francisco Alírio Almeida Gomes de, 1985 20 August 2018 (has links)
Orientador: Douglas Soares Galvão / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin / Made available in DSpace on 2018-08-20T20:43:55Z (GMT). No. of bitstreams: 1
Moura_FranciscoAlirioAlmeidaGomesde_M.pdf: 1452512 bytes, checksum: 5bfe0662fc16432eada98d772559aa36 (MD5)
Previous issue date: 2012 / Resumo: Nesse estudo, investigamos, utilizando ferramentas computacionais, o problema do desenvolvimento racional de polímeros molecularmente impressos (MIP). Utilizamos vários tipos de simulações moleculares: dinâmica molecular, simulated annealing e método de Monte Carlo para alcançar uma seleção de monômeros funcionais baseada em uma biblioteca de monômeros candidatos para uma dada substância-alvo de interesse. Aplicamos esses métodos à simulação das soluções pré-polimerização para a construção de um MIP para a substância 17ß-estradiol, que é uma molécula orgânica de interesse médico e ambiental. Fomos bem sucedidos em simular a solução pré-polimerização para nove monômeros diferentes e construímos uma lista ordenada de possíveis melhores candidatos dentre esses nove / Abstract: In the present study, we investigated by means of computational tools, the problem of rational design of Molecularly Impressed Polymers (MIP). We used several different types of simulations: molecular dynamics, simulated annealing and Monte Carlo method to achieve a selection of functional monomers based on a library of candidates for the functional monomers for some given target substance of interest. We applied these methods to pre-polimerization solutions for the design of a MIP for the substance 17ß-estradiol, which is an organic molecule of medical and environmental interest. We were successful in simulating the pre-polimerization solutions for nine different monomers and building an ordered list of possible best monomers among these candidates / Mestrado / Física / Mestre em Física
|
2 |
Determinação de tetraciclina utilizando eletrodos compósitos grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular / Determination of tetracycline using graphite-polyuretane composites electrodes modified with methacrylate molecularly imprinted polymersJosé Eduardo dos Santos Clarindo 27 September 2017 (has links)
Neste trabalho propôs-se desenvolver eletrodos compósitos à base de grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular (MIP-TC), visando a determinação do antibiótico tetraciclina em formulações farmacêuticas e urina sintética. O trabalho também visou contribuir no desenvolvimento de um sensor com melhor desempenho no que diz respeito à sensibilidade e seletividade do eletrodo compósito modificado, na quantificação do analito/molécula molde em matrizes complexas. Técnicas eletroanalíticas, tais como voltametria cíclica (CV) e voltametria de pulso diferencial (DPV) foram utilizadas para avaliar a resposta em termos de sensibilidade e seletividade do eletrodo compósito na detecção da tetraciclina (TC), proposto neste trabalho. A otimização dos parâmetros, tais como composição do MIP (5,0 %, m/m), amplitude de pulso (50 mV), velocidade de varredura (10 mV s-1), tempo (300 s) e potencial de acumulação [(+ 0,7 V (vs. SCE)] e faixa granulométrica do MIP (150 a 250 μm), usando voltametria de redissolução anódica por pulso diferencial foi realizada para maximizar a determinação da tetraciclina em tampão fosfato 0,10 mol L -1 (pH 2,5), permitindo obter limites de detecção de 0,555 μmol L-1, 2,70 μmol L-1 e 4,71 μmol L-1, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, sem necessidade de renovação da superfície do eletrodo entre as sucessivas medidas. Regiões lineares entre 4,0 e 60,0 μmol L-1, 8,0 e 60,0 μmol L-1 e 20,0 e 100,0 μmol L-1/sup> foram observadas, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, para o pico anódico em + 0,9 V (vs. SCE). Os EGPU também foram testados quanto à seletividade frente à possíveis interferentes, sendo utilizados clortetraciclina (CTC) e oxitetraciclina (OTC) para os testes de interferência. Em todos os casos, a interferência do EGPU-MIP-TC foi menor do que a obtida com o EGPU-NIP, confirmando que o EGPU-MIP-TC foi mais efetivo na capacidade de reconhecer seletivamente o analito na presença dos interferentes CTC e OTC. Após as etapas de síntese dos MIP/NIP e confecção dos eletrodos, otimização dos parâmetros, avaliações e testes de sensibilidade e seletividade dos EGPU, os eletrodos foram submetidos à aplicação em duas amostras de medicamentos comerciais, TetraMed® 500 mg e genérico de cloridrato de tetraciclina 500 mg e uma amostra sintética de urina. Os resultados foram comparados ao método oficial por HPLC, apresentando 95 % de confiança, de acordo com o teste t-Student. / In this work, graphite-polyurethane composites electrodes were modified with methacrylate molecularly imprinted polymers (MIP-TC) in order to evaluate the electrodes in the determination of tetracycline (TC) antibiotic in pharmaceutical formulations as well as in biological fluid. The work aimed to contribute in development of a sensor with better performance about the sensitivity and selectivity of the composites electrodes modified in quantification of this analyte. Electroanalytical techniques such as cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to evaluate the selectivity and sensitivity of the composite electrodes in the detection of tetracycline. The parameters optimization, such as MIP composition (5.0 %, m/m), pulse amplitude (50 mV), scan rate (10 mV s-1), accumulation time (300 s), accumulation potential [+ 0.7 V (vs. SCE)], and MIP granulometry (150 to 250 μm), using differential pulse anodic stripping voltammetry was done to maximize the determination of tetracycline in phosphate buffer 0.1 mol·L-1 pH 2.5 resulting in LOD of 0.555 μmol L-1, 2.70 μmol L-1 and 4.71 μmol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP, without the need for surface renovation between the measures. A linear dynamic range from 4.0 to 60.0 μmol L-1, 8.0 to 60.0 μmol L-1 and 20.0 to 100.0 μmol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP was observed for the anodic peak at + 0.9 V (vs. SCE). The EGPU were also tested regarding the selectivity compared to possible interferents, such as chlortetracycline (CTC) and oxytetracycline (OTC) for the interference study. In all cases, the interference of EGPU-MIP-TC was lower than the one that was got with EGPU-NIP, confirming that the EGPU-MIP-TC was more selective than the non-imprinted polymer in the capacity of recognizing, selectively, the analyte in presence of CTC and OTC interferents. After the steps of synthesis of MIP/NIP and electrodes confection, parameters optimization, evaluation and EGPU sensitivity and selectivity studies, the electrodes were submitted to the application in two commercial drugs containing 500 mg of tetracycline cloridrate, TetraMed® and generic; and a synthetic urine sample. The results were compared to the official method by HPLC, presenting 95 % confidence according to the t-Student test.
|
3 |
Determinação de tetraciclina utilizando eletrodos compósitos grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular / Determination of tetracycline using graphite-polyuretane composites electrodes modified with methacrylate molecularly imprinted polymersClarindo, José Eduardo dos Santos 27 September 2017 (has links)
Neste trabalho propôs-se desenvolver eletrodos compósitos à base de grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular (MIP-TC), visando a determinação do antibiótico tetraciclina em formulações farmacêuticas e urina sintética. O trabalho também visou contribuir no desenvolvimento de um sensor com melhor desempenho no que diz respeito à sensibilidade e seletividade do eletrodo compósito modificado, na quantificação do analito/molécula molde em matrizes complexas. Técnicas eletroanalíticas, tais como voltametria cíclica (CV) e voltametria de pulso diferencial (DPV) foram utilizadas para avaliar a resposta em termos de sensibilidade e seletividade do eletrodo compósito na detecção da tetraciclina (TC), proposto neste trabalho. A otimização dos parâmetros, tais como composição do MIP (5,0 %, m/m), amplitude de pulso (50 mV), velocidade de varredura (10 mV s-1), tempo (300 s) e potencial de acumulação [(+ 0,7 V (vs. SCE)] e faixa granulométrica do MIP (150 a 250 μm), usando voltametria de redissolução anódica por pulso diferencial foi realizada para maximizar a determinação da tetraciclina em tampão fosfato 0,10 mol L -1 (pH 2,5), permitindo obter limites de detecção de 0,555 μmol L-1, 2,70 μmol L-1 e 4,71 μmol L-1, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, sem necessidade de renovação da superfície do eletrodo entre as sucessivas medidas. Regiões lineares entre 4,0 e 60,0 μmol L-1, 8,0 e 60,0 μmol L-1 e 20,0 e 100,0 μmol L-1/sup> foram observadas, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, para o pico anódico em + 0,9 V (vs. SCE). Os EGPU também foram testados quanto à seletividade frente à possíveis interferentes, sendo utilizados clortetraciclina (CTC) e oxitetraciclina (OTC) para os testes de interferência. Em todos os casos, a interferência do EGPU-MIP-TC foi menor do que a obtida com o EGPU-NIP, confirmando que o EGPU-MIP-TC foi mais efetivo na capacidade de reconhecer seletivamente o analito na presença dos interferentes CTC e OTC. Após as etapas de síntese dos MIP/NIP e confecção dos eletrodos, otimização dos parâmetros, avaliações e testes de sensibilidade e seletividade dos EGPU, os eletrodos foram submetidos à aplicação em duas amostras de medicamentos comerciais, TetraMed® 500 mg e genérico de cloridrato de tetraciclina 500 mg e uma amostra sintética de urina. Os resultados foram comparados ao método oficial por HPLC, apresentando 95 % de confiança, de acordo com o teste t-Student. / In this work, graphite-polyurethane composites electrodes were modified with methacrylate molecularly imprinted polymers (MIP-TC) in order to evaluate the electrodes in the determination of tetracycline (TC) antibiotic in pharmaceutical formulations as well as in biological fluid. The work aimed to contribute in development of a sensor with better performance about the sensitivity and selectivity of the composites electrodes modified in quantification of this analyte. Electroanalytical techniques such as cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to evaluate the selectivity and sensitivity of the composite electrodes in the detection of tetracycline. The parameters optimization, such as MIP composition (5.0 %, m/m), pulse amplitude (50 mV), scan rate (10 mV s-1), accumulation time (300 s), accumulation potential [+ 0.7 V (vs. SCE)], and MIP granulometry (150 to 250 μm), using differential pulse anodic stripping voltammetry was done to maximize the determination of tetracycline in phosphate buffer 0.1 mol·L-1 pH 2.5 resulting in LOD of 0.555 μmol L-1, 2.70 μmol L-1 and 4.71 μmol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP, without the need for surface renovation between the measures. A linear dynamic range from 4.0 to 60.0 μmol L-1, 8.0 to 60.0 μmol L-1 and 20.0 to 100.0 μmol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP was observed for the anodic peak at + 0.9 V (vs. SCE). The EGPU were also tested regarding the selectivity compared to possible interferents, such as chlortetracycline (CTC) and oxytetracycline (OTC) for the interference study. In all cases, the interference of EGPU-MIP-TC was lower than the one that was got with EGPU-NIP, confirming that the EGPU-MIP-TC was more selective than the non-imprinted polymer in the capacity of recognizing, selectively, the analyte in presence of CTC and OTC interferents. After the steps of synthesis of MIP/NIP and electrodes confection, parameters optimization, evaluation and EGPU sensitivity and selectivity studies, the electrodes were submitted to the application in two commercial drugs containing 500 mg of tetracycline cloridrate, TetraMed® and generic; and a synthetic urine sample. The results were compared to the official method by HPLC, presenting 95 % confidence according to the t-Student test.
|
Page generated in 0.119 seconds