• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 227
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 228
  • 228
  • 162
  • 156
  • 42
  • 34
  • 33
  • 33
  • 31
  • 30
  • 29
  • 27
  • 25
  • 25
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Efetividade microbiológica da desinfecção por microondas e seus efeitos sobre a dureza de materiais reembasadores macios /

Pavan, Sabrina. January 2006 (has links)
Resumo: O objetivo deste estudo foi avaliar a efetividade da desinfecção utilizando energia por microondas sobre os materiais reembasadores macios Mollopast-B e Ufi Gel P contaminados com os microorganismos C. albicans, S. aureus, B. subtilis e P. aeruginosa. Além disso, foi analisado o efeito desta técnica na dureza dos materiais reembasadores macios. Para avaliar a efetividade da desinfecção, foram confeccionados 200 corpos-de-prova de cada material sobre bases de resinas termopolimerizadas seguindo as instruções dos fabricantes. Os corpos-de-prova foram imersos meio de cultura TSB inoculados com os microrganismos C. albicans, S. aureus, B. subtilis e P. aeruginosa e submetidos à desinfecção em microondas pelos tempos de 3, 4, 5 e 6 minutos a potência de 650W. Alíquotas da suspensão resultante das diluições seriadas de 10-2-10 -5 foram semeadas em placas de petri e após 48 h de incubação o número de colônias foi calculado (ufc/mL). Para a avaliação do efeito da desinfecção com energia por microondas sobre a dureza dos materiais, 40 corpos-de-prova de cada reembasador macio foram submetidos aos diferentes tempos de desinfecção em microondas (3, 4, 5 e 6 min). As mediadas de dureza foram realizadas com um durômetro shore A em diferentes períodos: imediatamente após a confecção dos corpos, 24, 48 h e após 7 dias. Os dados obtidos foram submetidos à Análise de Variância e ao teste de Tukey (p<0,01). Os resultados obtidos mostraram que: a - os tempos de 4, 5 e 6 minutos de irradiação com energia por microondas esterilizou os corpos-de-prova dos materiais Molloplast B e Ufi Gel P; b - 3 minutos de irradiação promoveu a desinfecção dos corpos-de-prova do material Molloplast B contaminados com B. subtilis, S. aureus e P. aeruginosa; c - a dureza apresentou maiores alterações nos tempos de desinfecção 5 e 6 min. / Abstract: The aim of this study was to evaluate the effectiveness of different times of exposure in microwave to disinfect two long-term soft lining materials (Molloplast B and Ufi Gel P) and the effects of this method on the hardness of these materials. Specimens of soft liners were made on an acrylic denture base resin and individually inoculated with C. albicans, S. aureus, B. subtilis and P. aeruginosa. After 24 hours at 37º C, 160 specimens of each material were individually submitted to microwave irradiation at 650 W for 3, 4, 5 and 6 minutes. Forty specimens were used as positive controls. Replicated specimens were plated on selective media appropriate for each microorganism. After incubation at 37ºC for 48 hours, colonies counts were quantified for each plated specimens (ufc/mL). To evaluate the effects of disinfection with microwave energy at different times of exposure on the hardness, fifty rectangular specimens (36 x 7 x 6 mm in thickness) were made for each material. Ten samples of each material were immersed in 200 mL of distilled water and disinfected in a microwave oven for 3, 4, 5 and 6 minutes at 650 W. The specimens were microwaved twice and hardness values were obtained with a Shore A durometer at different times: immediately after specimen fabrication and after 24, 48 hours and 7 days. Control specimens of each material were not disinfected and were maintained in distilled water during the role experimental period. Data were submitted to ANOVA and Tukey's test (p<0.01). The results showed that: a- sterilization was obtained at 6, 5 and 4 minutes of microwave irradiation for all specimens relined with Ufi Gel P and Molloplast B contaminated with all microorganisms; b- the specimens relined with Molloplast B contaminated with B. subtilis, S. aureus and P. aeruginosa and irradiated for 3 minutes demonstrated growth after incubation; c- the 6 minutes of microwave disinfection promoted the lower shore A hardness mean values for Molloplast. / Orientador: João Neudenir Arioli Filho / Coorientador: Denise Madalena Palomari Spolidorio / Banca: Helena de Freitas Oliveira Paranhos / Banca: Marcelo Ferraz Mesquita / Banca: Wirley Gonçalves Assunção / Banca: Francisco de Assis Mollo Junior / Doutor
122

Propriedade antifúngica de resina para base de prótese modificada com nanopartículas de prata

Wady, Amanda Fucci [UNESP] 17 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-17Bitstream added on 2014-06-13T19:00:20Z : No. of bitstreams: 1 wady_af_me_arafo.pdf: 531289 bytes, checksum: f03e54a3a96691d52c47dbbf0cd1479d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Apesar do uso de drogas antifúngicas no tratamento da estomatite protética, freqüentemente a infecção é persistente e a resistência microbiana tem sido observada nos biofilmes de Candida albicans. Dessa forma, existe a necessidade de se desenvolver outros agentes antimicrobianos tais como as nanopartículas de prata (AgNPs). Assim, o objetivo deste estudo foi avaliar o efeito de uma solução preparada de AgNPs sobre C. albicans em suspensão. Além disso, os efeitos da incorporação de diferentes concentrações da solução de AgNPs em uma resina acrílica para base de prótese e o armazenamento por períodos de até 180 dias no ângulo de contato, adesão e formação de biofilme foram avaliados. A solução de AgNPs foi sintetizada por meio de redução química utilizando borohidreto de sódio (NaBH4) como agente redutor e polivinil álcool (PVA) como estabilizante, e foi caracterizada utilizando espectroscopia UV-visível (UV-vis), espectrometria de infravermelho por transformada de Fourier (FTIR) e espalhamento de luz dinâmico (DLS). A susceptibilidade antimicrobiana da solução de AgNPs de diferentes concentrações (de 1000 a 20 ppm) foi avaliada em C. albicans suspensão (ATCC 90028). A solução de AgNPs foi também misturada com o pó da resina para produzir resinas acrílicas com AgNPs incorporadas nas concentrações finais de 1000, 750, 500, 250 e 30 ppm. Resina sem AgNPs foi utilizada como controle. Amostras em forma de discos (13 × 2 mm) de cada concentração (n=72) foram preparadas e armazenadas em PBS estéril por 0, 7, 90 e 180 dias (n=18). Após esses períodos, os ângulos de contato foram mensurados em um goniômetro. A seguir, 9 amostras de cada concentração foram utilizadas para o teste de aderência de C. albicans (90 minutos de incubação), e 9 para o teste de formação de... / Despite the use of antifungal drugs to treat denture stomatitis, infection is often persistent and antifungal resistance has been observed in C. albicans biofilms. Therefore, there is a need to develop alternative antimicrobial agents such as silver nanoparticles (AgNPs). Thus, the objective of this study was to evaluate the effect of a prepared AgNPs aqueous solution against C. albicans suspension. Additionally, the effects of incorporation of different concentrations of the AgNPs solution into a denture base acrylic resin and storage for up to 180 days on the contact angle, C. albicans adhesion and biofilm formation were evaluated. The AgNPs solution was synthesized by chemical reduction using sodium borohydride as reducing agent and polyvinyl alcohol as stabilizer, and was characterized by UV-visible spectroscopy, Fourier transform infrared spectroscopy and Dynamic Light Scattering. The antimicrobial susceptibility of AgNPs solution of different concentrations (from 1000 to 20 ppm) was performed against C. albicans suspension (ATCC 90028). The AgNPs solution was also mixed with the acrylic powder to produce silver-incorporated acrylic resins at the final concentrations of 1000, 750, 500, 250 and 30 ppm. Resin without AgNPs was used as control. Disk-shaped samples (13 × 2 mm) of each concentration (n=72) were prepared and stored in sterile PBS for 0, 7, 90 and 180 days (n=18). After the storage periods, the contact angles were measured in a goniometer. Then, 9 samples of each concentration... (Complete abstract click electronic access below)
123

Solução efervescente para higiene de próteses totais: influência na sorção de água, solubilidade, dureza e na alteração de cor de reembasadores / Effervescent solutions for denture hygiene: Influence in water sorption, solubility, hardness and color changes of denture liners

Antonio de Luna Malheiros Segundo 18 December 2007 (has links)
Este estudo avaliou propriedades físicas de materiais reembasadores para dentaduras após imersão em solução à base de perborato de sódio. Em todos os testes, os materiais, Kooliner e Elite Soft foram divididos nos grupos G1 (controle): imersão em saliva artificial a 37°C e G2 (experimental): imersões diárias em solução à base de perborato de sódio (Corega Tabs) por 5 minutos. Para os testes de sorção, solubilidade, alteração de cor e de dureza, foram obtidos 30 espécimes em forma de disco (15x3mm) de cada material, por meio da técnica direta, a partir da prensagem do material em matriz metálica vazada entre duas placas de vidro. A sorção e solubilidade foram avaliadas após 120 dias de imersão. A alteração de cor foi avaliada imediatamente após o acabamento dos corpos-de-prova e após 30 e 120 dias. A dureza dos materiais foi mensurada inicialmente, após 30 e 60 dias de imersão. O teste de Kruskal-Wallis (P<0,05) indicou que para o material Kooliner, o tipo de imersão (G1=1,43; G2=1,63) não interferiu nos valores de sorção. Quanto ao Elite soft, o perborato de sódio (G1=0,29; G2=0,51) promoveu aumento significativo nos valores de sorção. Comparando os materiais, o Kooliner apresentou médias de sorção significativamente mais altas que o Elite soft, para os dois grupos estudados. Para solubilidade, o teste Anova (P<0,05) a dois fatores de variação indicou diferença significante entre o fator grupo e entre o fator material. O Kooliner (0,168) bem como o grupo 1(0,137) apresentaram as maiores médias de solubilidade em relação ao Elite soft (0,089) e o grupo 2 , respectivamente. Com relação à cor (Anova, P<0,05), os dois materiais sofreram alteração no intervalo de 30 (Kooliner: G1=3,63, G2=2,87; Elite soft: G1=6,27, G2=6,01) e 120 (Kooliner: G1=4,21, G2=3,94; Elite soft: G1=8,54, G2=9,23) dias de imersão. O fator grupo não influenciou nesta propriedade dos materiais. Para a dureza do Kooliner, foi aplicada a análise de variância a dois fatores de variação (grupo: G1=6,63; G2=7,27 e tempo: T0=5,24; T30=7,28; T60=8,34), que indicou diferença somente para o fator tempo. Após a comparação das médias (Tukey=0,87), notou-se aumento significante (P<0,05) da dureza entre todos os tempos avaliados. Os corpos-de-prova de Elite soft do grupo experimental (49,18) apresentaram um aumento (P<0,05) na dureza quando comparado ao grupo controle (48,72). Para o fator tempo, o teste de Tukey (0,76), indicou diferença significante (P<0,05) entre as três médias (T0=46,45; T30=49,63; T60=50,74). O perborato de sódio não influenciou de forma significante nas propriedades avaliadas neste estudo. Dentre os materiais, o Kooliner foi o que apresentou maior estabilidade, porém é um material com características diferentes do Elite soft. O tempo é um fator importantíssimo na alteração das propriedades dos materiais, tendo interferido em todas as variáveis testadas. Estudos com o objetivo de aprimorar as características dos materiais para uma aplicação a longo prazo devem ser ainda realizados, visando a viabilidade de uso dos materiais reembasadores. / The aim of this study was to evaluate the physical properties of denture liners after immersion in a sodium perborate´s solution. In all the tests, both materials, Kooliner and Elite soft, were divided into the groups G1 (control): immersion in artificial saliva at 37°C and G2 (experimental): daily immersions in a sodium perborates´s solution (Corega Tabs) for five minutes. Thirty specimens (diameter of 15 mm and thickness of 3 mm) were obtained for the tests of water sorption, solubility, color change and hardness. Each material was processed according to the manufacturer´s directions in metallic moulds prepared for this purpose and compressed by two glass plates. Water sorption and solubility were evaluated after 120 of immersion. Color change was evaluated after specimens´ finishing, after thirty and sixty days of immersion. Kruskal Wallis (P<0,05) indicated that the immersion in sodium perborate (G1=1,43; G2=1,63) did not interfere in the water sorption values. Sodium perborate promoted significative raise in the Elite soft´s water sorption (G1=0,29; G2=0,51). Comparing the materials, Kooliner had the biggest means in both groups. In the solubility test, ANOVA (P<0,05), using two variation factors, indicated signifficant difference between groups and materials. Kooliner (0,168) and Group 1 (0,137) presented the biggest solubility means when compared with Elite soft (0,089) and Group 2 (0,110). Both materials changed between 30 (Kooliner: G1=3,63, G2=2,87; Elite soft: G1=6,27, G2=6,01) and 120 (Kooliner: G1=4,21, G2=3,94; Elite soft: G1=8,54, G2=9,23) days of immersion in the color test (Anova, P<0,05). To the Kooliner´s hardness, the ANOVA with two variation factors, indicated signifficant differece only for the time of immersion (grupo: G1=6,63; G2=7,27 e tempo: T0=5,24; T30=7,28; T60=8,34). Comparing the means (Tukey=0,87) a signifficant raise (P<0,05) of the hardness was observed between all the periods evaluated. Specimens of the experimental group of Elite soft (49,18) showed a raise (P<0,05) in the hardness when compared to the control group (48,72). The test of Tukey (0,76) indicated significant difference (P<0,05) in the time of immersion between the three means (T0=46,45; T30=49,63; T60=50,74). Sodium perborate did not influence significantly the properties evaluated in this study. Between the materials, Kooliner presented the best stability. But both materials have different compositions and behave in different ways clinically. The period of immersion is a very important factor in the physical properties of the materials; and all of them presented signifficant differences during this period. Studies with the intention of improving the materials´ properties for a long term use should be tried to make viable the use of denture liners.
124

Avaliação clínica e laboratorial de uma solução experimental para higiene de reembasador resiliente para prótese total / Clinical and laboratory evaluation of an experimental solution for hygiene of denture soft liners

Antonio de Luna Malheiros Segundo 17 May 2011 (has links)
Este estudo avaliou a eficácia de métodos de higiene na remoção do biofilme da prótese total inferior reembasada com reembasador resiliente à base de silicone. Trinta pacientes tiveram suas próteses inferiores reembasadas (Mucopren soft) e, aleatoriamente, foram distribuídos em três grupos: A) Método mecânico escovação com dentifrício (Corega Brite) e escova (Johnson & Johnson) específicos para prótese total; B) Método químico imersão em solução à base de Ricinus communis; C) Método associado associação A+B. O período experimental foi de 60 dias e para a quantificação do biofilme, a superfície interna da prótese total inferior foi evidenciada (Fluoresceína sódica 1%) e fotografada, após 15, 30 e 60 dias de utilização dos métodos. As áreas, total da prótese e a corada (biofilme), foram mensuradas com o software Image Tool 3.0 e os resultados expressos em porcentagem. A análise microbiológica foi realizada pela técnica de hibridização DNA-DNA checkerboard. Para a avaliação qualitativa do material reembasador, às próteses foram atribuídos escores (0, 1 e 2) em função da apresentação do material após os períodos avaliados. Os testes estatístico iniciais indicaram a distribuição não normal ou homogênea dos dados, optando-se pela transformação dos mesmos em raiz quadrada de forma a aplicar estatística paramétrica. Quanto a quantificação do biofilme, empregou-se o teste Anova seguido pelo teste complementar de Tukey considerando P<0,05. Houve diferença significante entre os métodos (P=0,009) e períodos (P=0,003) avaliados. Não houve interação entre os fatores (P=0,5). O método mecânico apresentou a menor média de porcentagem de biofilme (1,45±1,03) se comparado ao químico (2,96±1,98) e associado (2,71±1,76). Após 60 dias (3,37±2,04), o acúmulo de biofilme foi maior que após 15 (1,28±0,77) e 30 (2,46±1,54) dias de utilização dos métodos. Para análise da eficácia antimicrobiana, foi empregado o método linear generalizado, não havendo interação entre os tempos e métodos de higiene. Entre estes, das 38 espécies estudadas, em 10 houve diferença estatística para, sendo que o método de imersão apresentou os valores mais baixos de contagem destes microorganismos. Apenas uma espécie apresentou diferença entre os períodos. Após a análise visual, verificou-se que o nível de deterioração foi menor após os 60 dias de análise nos materiais reembasadores higienizados por meio da escovação. As próteses higienizadas pelo método mecânico apresentaram a menor porcentagem de área de biofilme e o menor nível de degradação do reembasador. O método químico apresentou maior eficácia na diminuição de contagem de microorganismos, inclusive nas espécies de Candida. / The aim of this study was to evaluate the effectiveness of hygiene methods on biofilm removal of the lower denture relined with a silicone material. Thirty patients had their lower dentures relined (Mucopren soft) and randomly divided into three groups: A) Mechanical method brushing with toothpaste (Corega Brite) and toothbrush (Johnson) specific for complete dentures; B) Chemical method immersion in Ricinus communis based solution; C) Associate method association of A and B. The experimental period lasted 60 days and for the biofilm quantification, the internal surface of the lower denture was evidenced (Sodium fluorescein 1%) and photographed, after 15, 30 and 60 days of use of the prostheses. Total and evidenced (biofilm) area of the dentures were measured by the software Image Tool 3.0 and the results were expressed in percentages. Microbiological analysis was performed by the DNA-DNA checkerboard technique. For the qualitative evaluation of the soft liner, scores were attributed to the prostheses (0, 1 and 2) according to the presentation of the material after evaluation periods. After verification of distribution and homogeneity of data, it was found that the distribution was not normal or homogeneous, opting for transformation in square root in order to apply parametric statistics. For the biofilm quantification, Anova was employed followed by the Tukeys test considering P<0,05. There were significant difference between the methods (P=0,009) and periods (P=0,003) evaluated. There was no interaction between the factors (P=0,5). Mechanical method presented the lowest mean percentage of biofilm. (1,45±1,03) when compared to the chemical (2,96±1,98) and to the associated method (2,71±1,76). After 60 days (3,37±2,04), the accumulation of biofilm was greater than after 15 (1,28±0,77) and 30 (2,46±1,54) days of the methods use. To analyze the antimicrobial efficacy, the generalized linear method was used. The test showed no interaction between periods and groups. Between groups, 10 of the 38 species evaluated presented statistical difference; and the immersion method showed the lowest counting values of those microorganisms. Only one specie presented statistical difference between the periods. After the visual analysis, it was found that the level of the dentures cleaned by the mechanical method exhibited the lowest percentage of biofilm area and presented the lowest level of degradation of the liner. The chemical method was more efficient in reducing the count of bacteria, including the Candida spp.
125

Estudo da alteração da dimensão vertical de oclusão (DVO) em dentaduras completas variando-se a fase de inserção da resina acrílica para microondas em mufla e utilizando-se a técnica do propiciador de espaço / Influence of acrylic resin stages and of the space propitiator technique on vertical dimension of occlusion in total dentures

Adriana Oshiro 21 September 2007 (has links)
As alterações de dimensão vertical de oclusão em dentaduras completas foram avaliadas através da mudança da fase de inserção (arenosa ou pegajosa) da resina acrílica de microondas Onda-Cryl em muflas próprias com a utilização ou não da técnica do propiciador de espaço. Foram confeccionadas dentaduras superiores em cera, corretamente articuladas com uma dentadura inferior previamente montada em articulador semi-ajustável, sendo realizadas as medidas de dimensão verticais iniciais através de um relógio micrométrico. Estas próteses superiores em cera foram divididas em quatro grupos de 10 elementos cada para acrilização: grupo F (inserção da resina acrílica na fase fibrilar em mufla, sem a utilização da técnica do propiciador de espaço), grupo FP (inserção na fase fibrilar, com utilização da técnica do propiciador de espaço), grupo A (fase arenosa, sem a técnica do propiciador de espaço) e grupo AP (fase arenosa, com a técnica do propiciador de espaço). O ciclo de polimerização em todos os grupos foi de 3 minutos a 30% da potência, 4 minutos com 0 (zero) de potência e 3 minutos a 90% da potência, em forno microondas de 800 Watts, conforme as instruções do fabricante. Após a acrilização, as dentaduras superiores, juntamente com seus respectivos modelos, foram remontadas no articulador semi-ajustável (através da técnica do split-cast com imã), onde novas medidas foram tomadas e comparadas com as iniciais. Os resultados foram submetidos à análise estatística e demonstraram que a técnica do propiciador de espaço foi efetiva na diminuição das alterações de dimensão vertical e que a mudança da fase de inserção da resina, embora não estatisticamente significante, também provoca uma redução dessas alterações. / Changes in vertical dimension of occlusion in maxillary complete dentures were evaluated after modifying Onda Cryl acrylic resin insertion stages (sandy or stringy) in specifics flasks or employing or not a space propitiator technique. Forty maxillary wax total dentures were made and randomly assigned in four groups, each one with 10 elements. They were all mounted in a semi-adjustable articulator and the initial vertical dimension measurements were recorded by the means of a gauging device attached to the articulator\'s guideline. The 4 groups were: Group S (Stringy stage, no use of space propitiator technique), Group SP (Stringy stage associated with the space Propitiator technique), Group Sn (Sandy stage, no use of space propitiator technique) and Group SnP (Sandy stage associated with the space Propitiator technique). All specimens were processed in a domestic microwave oven according to Onda cryl manufacturer\'s instructions. After the curing cycle, the flask was removed from the oven, remaining on the bench until its full cooling and the remounted standardized dentures were replaced in the articulator were reevaluated. The vertical dimensional alterations values were submitted to statistical analysis. Space propitiator technique was effective on reducing the vertical dimension alterations and changing the resin stage (sandy instead stringy stage) results in minor alterations on vertical dimension, although not statiscally significant.
126

Processamento de próteses totais: influência de 4 técnicas na alteração daposição dos dentes artificiais. / The processing of complete denture: influence of four techniques in artificial teeth movement.

William Barnabé 03 April 2000 (has links)
O processamento de resinas acrílicas utilizadas na confecção de bases de prótese envolve alterações dimensionais e distorções da base e movimentação dos dentes artificiais que podem levar à não utilização das próteses por desadaptação, dificuldade de engrenamento dos dentes e estética. Esse estudo avaliou a relação entre a movimentação dos dentes artificiais com os procedimentos de inclusão, prensagem e polimerização das bases de próteses totais. Foram utilizadas 64 amostras, divididas em quatro grupos de 16 (8 inferiores e 8 superiores) que receberam o seguinte tipo de inclusão, prensagem e processamento: a) grupo 1: neste grupo todas as amostras foram incluídas em muflas reforçadas de fibra de vidro, com muralha de silicona, prensagem por uma hora e polimerização em microondas, b) grupo 2: neste grupo todas as amostras foram incluídas em muflos metálicos, com muralha de silicona, prensagem por 12 horas e polimerização em banho de água, utilizando o ciclo de curta duração, c) grupo 3: neste grupo todas as amostras foram incluídas em muflas reforçadas de fibra de vidro, adaptadas para injetora de acrílico, com muralha de gesso pedra e polimerização em microondas, uma hora após a injeção do molde e d) grupo 4: neste grupo todas as amostras foram incluídas em muflos metálicos, com muralha de silicona, prensagem por uma hora e polimerização em banho de água, utilizando o ciclo de curta duração. Com os resultados obtidos podemos concluir que: a) todas as amostras sofreram contração após o processamento, b) a técnica com menor movimentação dos dentes artificiais foi a técnica 1, que apresentou diferença estatisticamente significativa em relação às demais c) quando comparados os arcos superiores e inferiores, independente da técnica e das medidas avaliadas, não se percebeu diferença estatisticamente significativa d) O tempo de prensagem, após a inclusão e antes da polimerização das próteses, interferiu na movimentação dos dentes artificiais e e) a medida que apresentou maior alteração foi a distância entre os molares, com diferença estatisticamente significativa com as demais. / The processing of acrylic resins used in the construction of complete denture bases involve dimensional alterations, distortion and artificial tooth movement which may prevent the prosthesis from being used due to discomfort, inadequate occlusion and esthetics. This study evaluated the relationship between artificial tooth movement, with the procedures of inclusion, compression and polymerization of complete dentures bases. The sixty-four samples utilized were divided into four groups of 16 (8 lower and 8 upper) which received the following type of inclusion, compression and processing: a) group 1: in this group all samples were included in resin-fiber reinforced flasks, with a silicone mould, compression for one hour and microwave polymerization; b) group 2: in this group all samples were included in metallic flasks, with a silicone mould, compression for 12 hours and thermopolymerization in water bath, using a short duration cycle; c) group 3: in this group all samples were included with gypsum stone mould using an acrylic injector to insert the resin inside the flasks, followed by microwave polymerization, one hour after mould injection and; d) group 4: in this group all samples were included in metallic flasks, with a silicone mould, compression for one hour and thermopolymerization in water bath, using short duration cycle. According to the results the following conclusions were drawn: a) contraction was observed in all samples after processing; b) group 1 presented statistically significant less artificial tooth movement, relative to the others; c) comparing the upper and lower arches, regardless of the technique and measurements evaluated, no statistically significant difference was found; d) the compression time following inclusion and before prostheses polymerization had a negative effect on artificial tooth movement and e) the biggest discrepancies were found in the distance between contralateral molars, with statistically significant difference to other measurements.
127

Hidrofobicidade superficial e colonização de Candida albicans sobre resina acrílica termopolimerizável para confecção de bases de próteses totais após desinfecção química / Surface hydrophobicity and Candida albicans colonization on heat-cure acrylic resin for denture base after chemical disinfection

Emilio Jose Tabare Rodriguez Acosta 17 August 2009 (has links)
A utilização de soluções químicas para desinfecção de próteses totais constitui atualmente uma das opções para a manutenção da limpeza e saúde na cavidade oral de pacientes portadores de dentaduras. O objetivo deste estudo foi avaliar o efeito de duas soluções desinfetantes (Hipoclorito de sódio 1% e Gluconato de clorexidina 4%), na hidrofobicidade superficial e adesão de Candida albicans ATTC 90028 sobre resina acrílica termopolimerizável, inicialmente e após 1, 7, 15 e 30 ciclos de desinfecção química, além de verificar o efeito da formação da película adquirida salivar sobre as duas variáveis avaliadas através de mensuração de ângulo de contato e microscopia de fluorescência. Para a mensuração da hidrofobicidade superficial 18 espécimes (10 x 25 x 2 mm) foram confeccionados em resina acrílica termopolimerizável e desinfetados, simulando a implementação de um protocolo de desinfecção diária durante 30 dias. Após completar o número de desinfecções de cada um dos períodos avaliados, mensurações de ângulo de contato foram feitas antes e depois da formação da película adquirida salivar. Para os testes de adesão de C. albicans à resina acrílica termopolimerizável, 180 espécimes (5 x 5 x 1 mm) foram confeccionados em resina acrílica termopolimerizável e desinfetados e divididos em vários períodos (Inicial-1-7-15-30 ciclos de desinfecção). Após completar o número de desinfecções de cada um dos períodos avaliados, foram feitos ensaios de adesão de C. albicans utilizando o fluorocromo laranja de acridina para posterior visualização mediante o uso de microscópio de fluorescência. Os dados de hidrofobicidade superficial foram analisados através do teste paramétrico ANOVA medidas repetidas e T-Student. Para os resultados de adesão de C. albicans foi utilizado o teste não paramétrico Kruskall Wallis e teste de Dunn. Para correlacionar as variáveis foi utilizado o teste de Pearson. Os resultados obtidos demonstraram que a imersão da resina acrílica em soluções desinfetantes diminui a adesão de C. albicans e os valores de hidrofobicidade superficial em todos os grupos após 30 desinfecções químicas. A formação da película adquirida salivar diminui a adesão de C. albicans e hidrofobicidade Resumo superficial, em todos os grupos após 30 desinfecções químicas. Não existe correlação entre os valores de adesão de C. albicans e hidrofobicidade superficial da resina acrílica termopolimerizável após desinfecção química, exceto para os grupos controle e Gluconato de clorexidina 4% prévio a formação da película adquirida salivar. / The use of chemical solutions for dentures disinfection currently constitutes one of the options for the maintenance of the cleanness and oral health of dentures users. The objective of this study was to evaluate the effect of two disinfecting solutions (Sodium Hypochlorite 1% and Gluconate chlorhexidine 4%), on the acrylic resin surface hydrophobicity and adhesion of Candida albicans ATTC 90028 on the heat-cure acrylic resin before and after 1, 7, 15 and 30 chemical disinfectant cycles. Furthermore to verify the effect of the formation of the acquired salivary pellicle on the variables, evaluated through contact angle measurements and fluorescence microscopy. For the surface hydrophobicity assay, 18 specimens (10 x 25 x 2 mm) had been confectioned in heat cure acrylic resin and disinfected, simulating the implementation of a daily dentures chemical disinfection protocol, during 30 days. After each disinfection period, contact angle measurements were made before and after the acquired salivary pellicle formation. For C. albicans adhesion assay, 180 specimens (5 x 5 x 1 mm) had been confectioned in heat cure acrylic resin, chemically disinfected and divided in: Initial, 1, 7, 15 and 30 disinfection cycles. After completed each period of chemical disinfection C. albicans adhesion analysis had been made using, fluorocrome acridine orange for posterior visualization by the use of fluorescence microscope. The data of acrylic resin surface hydrophobicity had been analyzed through parametric test ANOVA repeated measures and T-Student. For the C. albicans adherence results, Kruskall Wallis no parametric test and Dunns test were used. To correlate the variables Pearson test were used. The results had demonstrated that the immersion of the heat cure acrylic resin in disinfecting solutions diminishes the adhesion of C. albicans and the values of acrylic resin surface hydrophobicity, in all the groups, in a period of 30 cycles. The formation of the acquired salivary pellicle diminishes the adhesion of C. albicans and acrylic surface hydrophobicity in all the groups in a period of 30 cycles. Correlation does not exist Abstract between the values of C. albicans adhesion and acrylic surface hydrophobicity after chemical disinfection, except for the Control group and Gluconate chlorhexidine 4% group before the formation of the acquired salivary pellicle.
128

Avaliação clínica e laboratorial de uma solução experimental à base de Ricinus communis em comparação ao hipoclorito de sódio para higiene de próteses totais / Clinical and laboratorial evaluation of an experimental solution based on Ricinus communis compared to sodium hypochlorite for denture cleansing

Mauricio Malheiros Badaró 06 December 2013 (has links)
Este estudo clínico-laboratorial avaliou uma solução à base de Ricinus communis para higiene de próteses totais, comparando-a ao hipoclorito de sódio, quanto à efetividade na remoção do biofilme, remissão de Candidíase Atrófica Crônica, grau de satisfação dos pacientes e rugosidade superficial da resina acrílica termopolimerizada. Sessenta e quatro usuários de próteses totais com ausência (n=40) ou presença de Candidíase (n=24) foram selecionados e orientados a escovar as próteses com escova específica e sabão neutro por 3 minutos, 3 vezes ao dia e imergi-las nas soluções de higiene (Hipoclorito de sódio 0,25% - S1; e 0,5% - S2; R. communisa 10% - S3; Salina - S4: controle) por 20 minutos. As soluções foram utilizadas de forma cruzada e randomizada com períodos de \"wash out\". Para quantificação do biofilme (ImageTool 3.0), a superfície interna foi evidenciada (vermelho neutro 1%) e fotografada ao final de cada período. A remissão da Candidíase foi avaliada por atribuição de escores antes e após o uso das soluções. A satisfação dos pacientes foi analisada por questionário. A rugosidade da superfície polida e não polida de 40 espécimes (90x30x4mm) de resina foi avaliada antes e após a exposição dos mesmos ao protocolo clínico de higiene por meio de rugosímetro e Microscopia Eletrônica de Varredura. A remoção do biofilme foi analisada como um \"split-plot\" com dois fatores de variação: presença de inflamação e soluções. A remissão da Candidíase foi analisada após ajuste dos dados por regressão logística multinomial. Para análise da satisfação dos pacientes os dados foram ajustados por regressões logísticas e foi adotada análise de simetria composta. Para avaliação da rugosidade das superfícies polida e não polida foi empregada análise de variância com dois fatores (período e solução). Todas as análises foram realizadas com nível de significância de 5%. Não houve diferença na porcentagem de biofilme entre pacientes com e sem inflamação, bem como na interação entre os fatores. Houve diferença entre soluções, sendo que o Hipoclorito de sódio a 0,25 e 0,5% promoveu as menores médias de biofilme (4,41±7,98 e 2,93±5,23), seguido do R. communis(6,95±10,93) e Salina (11,07±11,99). Para remissão da Candidíase, as soluções mais eficientes foram R. communis(50%) e Hipoclorito de sódio 0,25% (46%). O questionário de satisfação não indicou diferença entre as soluções. A rugosidade da superfície polida não foi alterada pelo período (p=0,062). Houve alteração em função das soluções (p=0,00) e da interação entre os fatores (p=0,005). Para S1 e S4, o período não influenciou na rugosidade. Para S2, houve alteração a partir de 07 dias, permanecendo estável após 14 dias. Para S3, houve alteração e estabilização a partir de 14 dias. Após 07 e 14 dias, S2 e S3 promoveram as maiores alterações, porém após 21 dias, não houve diferença entre as soluções, exceto a salina. A superfície não polida não foi influenciada pelos fatores período (p=0,358), solução (p=0,120) e interação (p=0,204). Concluiu-se que há viabilidade do uso do hipoclorito de sódio em menores concentrações e do Ricinus communis para remoção do biofilme, remissão da Candidíase e controle da rugosidade superficial. / This clinical-laboratory study evaluated a solution based on Ricinus communis for denture cleansing, comparing it to sodium hypochlorite, regarding biofilm removal capacity, remission of atrophic chronic candidiasis, degree of patient satisfaction and surface roughness of heat-polymerized acrylic resin. Sixty-four denture wearers with absence (n = 40) or presence of Candidiasis (n = 24) were selected and oriented on how to brush their dentures with a specific brush and mild soap for 3 minutes, 3 times a day and immerse them in hygiene solutions (0.25% sodium Hypochlorite - S1 and 0.5% - S2, R. communis 10% - S3; Saline - S4: control) for 20 minutes. The solutions were used in a randomized and cross form with \"washout\" periods. To quantify biofilm (ImageTool 3.0), the inner surface was disclosed (1% neutral red) and photographed at the end of each period. The remission of Candidiasis was assessed by assigning scores before and after using solutions. Patient satisfaction was assessed by questionnaire. The surface roughness of 40 polished and unpolished resin specimens (90x30x4mm) was evaluated before and after their exposure to clinical protocol hygiene by surface roughness and scanning electron microscopy. The biofilm removal was analyzed as a \"split-plot\" with two variation factors: inflammation and solutions. The candidiasis remission was analyzed after adjustment using multinomial logistic regression. For patient satisfaction logistic regression analysis was adopted and compound symmetry. For evaluation of surface roughness polished and unpolished was employed analysis of variance with two factors (time and solution). All the analysis were performed with a significance level of 5 %. There was no difference in the percentage of biofilm between patients with and without inflammation, as well as the interaction between the factors. There were differences among the solutions, having the Sodium Hypochlorite 0.25 % and 0.5% promoted the lowest average biofilm (4.41±7.98 and 2.93±5.23), followed by R. communis (6.95±10.93) and Saline (11.07±11.99) . For the remission of candidiasis, the most efficient solutions were R. communis (50%) and 0.25% sodium hypochlorite (46%). The satisfaction questionnaire indicated no difference among the solutions. The roughness of the polished surface was not affected by time (p = 0.062). There was a change in function of the solutions (p = 0.00) and the interaction between factors (p = 0.005). For S1 and S4, the period did not influence the roughness. For S2, there was a change from 07 days, remaining stable after 14 days. For S3, there were changes and stabilization from 14 days. After 7 and 14 days, S2 and S3 promoted major changes, but after 21 days, there were no difference among the solutions except the saline. The unpolished surface is not influenced by factors: period (p = 0.358), solution (p = 0.120) and interaction (p = 0.204). It was concluded that there is feasibility for using sodium hypochlorite at lower concentrations and Ricinus communis for the removal of biofilm, remission of candidiasis and control of surface roughness.
129

"Avaliação da retenção de prótese total bimaxilar em função das características da área basal" / Evaluation of the retention of bimaxillay complete denture in function of the characteristics of the basal area.

Eudes Francisco da Silva Cunha 28 January 2005 (has links)
Nesta pesquisa, em 14 pacientes da Clínica de Prótese Total da Faculdade de Odontologia da Universidade de São Paulo, foi realizada a avaliação da retenção de prótese total bimaxilar em função das características da área basal por três avaliadores clínicos experientes e calibrados. Foram avaliadas as retenções vertical anterior, laterais direita e esquerda e póstero-anterior e as características da área basal: forma, tamanho, altura e tipo do rebordo e a consistência da fibromucosa. Por se tratarem de opiniões, os dados foram transformados em escores e submetidos à análise de variância não paramétrica com o teste KRUSKAL-WALLIS e paramétrica com o teste ANOVA. Concluiu-se que, na maxila, a retenção das próteses totais novas foi influenciada positivamente pelo tipo rebordo paralelo e pela consistência resiliente da fibromucosa, enquanto na mandíbula influenciaram o tamanho médio e a forma oval. As opiniões sobre a retenção e o grau de satisfação entre os avaliadores e os pacientes foram as mesmas. / In this research, a evaluation of the retention of bimaxilar complete denture in function of the characteristics of the basal area by three calibrated experienced clinician was accomplished in 14 patients of the Odontology College of the University of São Paulo. The anterior vertical retention, right lateral retention, left lateral retention, posteroanterior retention and rigde shape, ridge size, rigde height, ridge type and the fibromucosa consistency were evaluated. Because of they are opinions, the data were trans formed in scores and submitted to the no parametric variance analysis with the KRUSKAL-WALLIS and ANOVA parametric tests. Conclusion, in the maxilla, the retention of the new complete denture, was positively influenced by the parallel rigde type and by the resilient consistency of the fibromucosa, while in the mandible, the decisive factors of the retention were the medium size of the rigde and the oval shape of this. The opinions about the retention and the level of satisfaction had been the same among the appraisers and patients.
130

"Análise da laterotrusão condilar nos movimentos de lateralidade centrífuga e de Bennett em edentados completos" / Condyle laterotrusion analysis on Bennett’s side shift and centrifuge lateral movements in edentate subjects

Eder Jun Hatushikano 22 May 2006 (has links)
Atualmente na odontologia ainda há muita dificuldade na compreensão do movimento de Bennett ou laterotrusão. Devido a questões de inviolabilidade inerentes à característica da articulação temporomandibular não é possível observar diretamente o seu interior, de maneira que a análise da sua dinâmica durante a função torna-se questionável. Assim, o autor trabalhou com imagens e inferências aplicadas numa metodologia utilizada para tal fim. A proposta dessa pesquisa foi a de analisar o comportamento condilar durante os movimentos de lateralidade Centrífuga e de Bennett em pacientes portadores de prótese total. Vinte e dois indivíduos receberam novas próteses totais. O registro maxilomandibular foi realizado com a técnica de Gysi com a plataforma e pua extraoral. Utilizando-se uma pua modificada de forma que esta realizasse dois registros (pua dupla) com o mesmo movimento e, ao invés da cera aplicada sobre a plataforma, o registro foi feito sobre um fino papel carbono aderido a esta com uma fita adesiva dupla face. Através de imagens digitalizadas do articulador e dos registros no carbono foi possível, com a utilização de um programa de tratamento de imagens, arbitrar e testar a posição do eixo vertical de rotação condilar durante a lateralidade centrífuga e de Bennett. Os resultados mostraram uma predominância nos eventos onde o eixo vertical do côndilo posicionou-se na região ântero-lateral e póstero-medial durante a lateralidade de Bennett, porém mostrou uma predominância de eventos localizados na região póstero-medial durante a lateralidade Centrífuga. Houve casos onde o eixo vertical localizou-se exatamente sobre o centro da esfera, o que indica que o paciente durante a lateralidade não promoveu excursão do côndilo de trabalho, realizando um movimento de rotação puro se analisado no plano horizontal. De acordo com a metodologia aplicada nessa pesquisa concluiu-se que o eixo da lateralidade Centrífuga é mais medial que o da lateralidade de Bennett e que a maior parte dos eixos não coincide com aquele sobre o centro da esfera condilar. / It has been controversial the understanding of both the Bennett’s side shift and Centrifuge lateral movements. Had the inherent questions of TMJ´s inviolability it is not possible to observe its interior directly, thus the analysis of its dynamics during the function becomes questionable. The author worked with images and inferences applied to a methodology used for such end. The proposal of this research was to analyze the behavior of jaw condyle Bennett’s side shift and Centrifuge lateral movements in complete denture wearers. Twenty two subjects had new dentures constructed. The mandible tracings were made using the technique of Gysi with an extra oral device with two registration markers. Instead of wax it was applied a fine articulating paper adhered to the platform by a double face adhesive ribbon. Digitalized images from articulator and from articulating papers were set together. It was used a software of treatment of images both to decide and to test the position of the vertical axle of rotation of the jaw during the Bennett’s side shift and during Centrifuge lateral movement. The results were a predominance of the events where the vertical axis were located in the backward medial region for the centrifuge lateral movement and were located both in the backward medial and in the forward lateral region for the Bennett’s side shift. It had cases where the vertical axle was situated accurately on the center of the condyle sphere, what is supposed to mean that the patient, during the lateral jaw movement did not promote excursion of the working side condyle. In accordance with the methodology applied in this research, the author concluded that the axis of the centrifuge lateral movement is more medial than the one of the Bennett’s side shift, and that in the great majority of the events the axis did not met the condyle sphere of the articulator.

Page generated in 0.0583 seconds