• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo teórico-experimental da ligação entre pilares mistos preenchidos e vigas pré-moldadas de concreto / Experimental and theoretical study of precast concrete beam to concrete-filled steel tube column connection

Bezerra, Leonardo Melo 27 May 2011 (has links)
Neste trabalho, ligações entre vigas pré-moldadas de concreto e pilares mistos preenchidos foram propostas com a finalidade de transferir momento de flexão e força cortante das vigas para os pilares mobilizando os núcleos de concreto. Foi realizado um estudo numérico-experimental das ligações onde foi avaliada a viabilidade e a eficiência destas na transferência dos esforços. Em uma primeira fase, modelos compostos por pilar misto e consolo metálico (modelos 1 e 2) foram confeccionados, testados experimentalmente e modelados numericamente (método dos elementos finitos) para avaliar a eficiência do consolo na transferência da força cortante. Observou-se que a transferência da força cortante do consolo para o tubo metálico foi eficaz. O consolo se comportou de maneira previsível e suportou cargas elevadas. O uso de conectores de cisalhamento internos aos pilares aumentou a capacidade de carga e o desempenho dos mesmos. Na etapa seguinte da pesquisa foram confeccionados dois modelos, compostos por: pilar, viga pré-moldada, laje e consolo formando pórticos. Em um destes modelos (modelo 4) uma caixa metálica foi incorporada à viga pré-moldada e parafusado ao consolo metálico com a finalidade de transferir os momentos positivos, enquanto que outro modelo foi confeccionado e estudado sem este elemento (modelo 3). Nestes modelos foi avaliada a capacidade de transferência do momento de flexão (positivo e negativo) e forças cortantes com a ligação submetida a ciclos de carga. No modelo 3, a ligação transferiu de forma eficiente o momento negativo, porém o desempenho para o momento positivo não foi satisfatório, com baixa resistência e rigidez ao longo dos ciclos de carga. No modelo 4 foi observado considerável aumento da resistência e rigidez se comparado com o modelo anterior. Entretanto, a caixa metálica incorporada à viga pré-moldada não foi capaz de fazer com que a ligação resistisse aos momentos positivos como a mesma eficiência que resistiu aos negativos e houve degradação de suas características estruturais ao longo dos ciclos de carga. / In this work, connections of precast concrete beam to concrete-filled steel tube column were proposed to transfer the bending moment and shear forces from the beam to the composite column, mobilizing the concrete core. Was performed a numerical and experimental study of the proposed connections to evaluate the feasibility and effectiveness of them in the transfer of bending and shear forces from the beam to the column. In a first stage, models composed by column and steel corbel (models 1 e 2) were numerically and experimentally tested aiming the efficiency of the connection in shear transfer. It was observed that the transfer of shear to the steel tube was guaranteed. The corbel behaved in a predictable way and supported high loads. The use of shear connectors in the column increased the load capacity and improved the connection performance. In next stage of the research work, two models were prepared, composed by: column, precast concrete beam, steel corbel and slabs constituting frames. In one of these models (model 4) a steel box was incorporated into the precast beam and bolted to the steel corbel in order to transfer the positive moments, whereas another model was built and studied without this device (model 3). In this models were evaluated the efficiency in the transfer of bending moments (positive and negative) and shear forces with the models subjected to a cyclic loads. In the model 3, the connection transferred efficiently the negative bending, but the performance for the positive bending was not satisfactory, with reduced strength and stiffness over the load cycles. In model 4 was observed considerable increase in strength and stiffness compared with the previous model. However, the device incorporated in the precast beam was unable to make the connection resist to the positive moments with the same efficiency observed when subjected to the negative moments and a degradation of their structural characteristics was observed during the loading cycles.
2

Considerações sobre o projeto, cálculo e detalhamento de vigas pré-fabricadas protendidas com aderência inicial em pavimentos de edificações / Considerations on the design, calculation and detailing of precast beams prestressing with pre-tensioning on buildings floors

Inforsato, Thiago Bindilatti 30 July 2009 (has links)
Made available in DSpace on 2016-06-02T20:09:11Z (GMT). No. of bitstreams: 1 2580.pdf: 4760065 bytes, checksum: 5236258da515ebb08b8d6b0431607f59 (MD5) Previous issue date: 2009-07-30 / This work shows a calculation sequence to determine and detail the longitudinal and transverse reinforcement of prestesses beams with pre-composed section. All procedures are done in a way that meets all the requirements of NBR6118: 2003 and 9062:2006 Code. It shows how the checks can be made of the ultimate state limit and the cracking service state and determining whether there is need for the isolation of the strand. The prestesses loss are considered taking into account the age of the constituents of the concrete section at the time when each step is performed and the procedure for progressive loss. The assumptions adopted for the calculation as composite section and the respective transverse reinforcement are detailing. It can be done as the detailing of transverse reinforcement with special care for the end of the piece where it is common the use of dapped-end. Four numerical examples are solved showing how the recommended calculation sequence allows the designer immediately realize the best solution, including the need for the use of prestressed strand along the top edge. The results obtained in the examples it can be seen: the advantage of using the section Ibeam, the semi-rigid connection has a limited efficiency even with large amounts of negative reinforcement, because the existence of the dapped-end, that considering the effect of prestressing causes the shear reinforcement required is minimal. Finally we can conclude that in several instances the situation critical for obtaining the longitudinal reinforcement was in service with the decompression. / Este trabalho mostra um roteiro para determinar e detalhar as armaduras longitudinal e transversal de vigas pré-tracionadas com seção composta. Todos os procedimentos são feitos de maneira que atenda a todas as prescrições das normas NBR 6118:2003 e NBR 9062:2006. Apresentam-se como podem ser feitas as verificações do estado limite último assim como em serviço de fissuração e determinando se há necessidade do isolamento das cordoalhas. As perdas de protensão são consideradas levando-se em conta a idade dos concretos constituintes da seção na época em que cada etapa é executada e o procedimento de perdas progressivas. As hipóteses adotadas para o cálculo como seção composta e respectiva armadura de costura são detalhadas. Mostra-se como pode ser feito o detalhamento da armadura transversal com especial cuidado para a extremidade da peça onde é comum o uso de dente Gerber. Quatro exemplos numéricos são resolvidos mostrando como o roteiro recomendado permite ao projetista perceber logo a melhor solução, inclusive da necessidade do uso de protensão junto a borda superior. Pelos resultados obtidos nos exemplos percebe-se: a vantagem do uso da seção em forma de I; que a ligação semi-rígida tem pequena eficiência mesmo com grande quantidade de armadura negativa, devido a existência do dente Gerber; que considerando o efeito da protensão faz com que a armadura de cisalhamento necessária seja a mínima. Finalmente pode-se concluir que nos diversos exemplos a situação determinante para a obtenção da armadura longitudinal foi a em serviço com a descompressão.
3

Estudo teórico-experimental da ligação entre pilares mistos preenchidos e vigas pré-moldadas de concreto / Experimental and theoretical study of precast concrete beam to concrete-filled steel tube column connection

Leonardo Melo Bezerra 27 May 2011 (has links)
Neste trabalho, ligações entre vigas pré-moldadas de concreto e pilares mistos preenchidos foram propostas com a finalidade de transferir momento de flexão e força cortante das vigas para os pilares mobilizando os núcleos de concreto. Foi realizado um estudo numérico-experimental das ligações onde foi avaliada a viabilidade e a eficiência destas na transferência dos esforços. Em uma primeira fase, modelos compostos por pilar misto e consolo metálico (modelos 1 e 2) foram confeccionados, testados experimentalmente e modelados numericamente (método dos elementos finitos) para avaliar a eficiência do consolo na transferência da força cortante. Observou-se que a transferência da força cortante do consolo para o tubo metálico foi eficaz. O consolo se comportou de maneira previsível e suportou cargas elevadas. O uso de conectores de cisalhamento internos aos pilares aumentou a capacidade de carga e o desempenho dos mesmos. Na etapa seguinte da pesquisa foram confeccionados dois modelos, compostos por: pilar, viga pré-moldada, laje e consolo formando pórticos. Em um destes modelos (modelo 4) uma caixa metálica foi incorporada à viga pré-moldada e parafusado ao consolo metálico com a finalidade de transferir os momentos positivos, enquanto que outro modelo foi confeccionado e estudado sem este elemento (modelo 3). Nestes modelos foi avaliada a capacidade de transferência do momento de flexão (positivo e negativo) e forças cortantes com a ligação submetida a ciclos de carga. No modelo 3, a ligação transferiu de forma eficiente o momento negativo, porém o desempenho para o momento positivo não foi satisfatório, com baixa resistência e rigidez ao longo dos ciclos de carga. No modelo 4 foi observado considerável aumento da resistência e rigidez se comparado com o modelo anterior. Entretanto, a caixa metálica incorporada à viga pré-moldada não foi capaz de fazer com que a ligação resistisse aos momentos positivos como a mesma eficiência que resistiu aos negativos e houve degradação de suas características estruturais ao longo dos ciclos de carga. / In this work, connections of precast concrete beam to concrete-filled steel tube column were proposed to transfer the bending moment and shear forces from the beam to the composite column, mobilizing the concrete core. Was performed a numerical and experimental study of the proposed connections to evaluate the feasibility and effectiveness of them in the transfer of bending and shear forces from the beam to the column. In a first stage, models composed by column and steel corbel (models 1 e 2) were numerically and experimentally tested aiming the efficiency of the connection in shear transfer. It was observed that the transfer of shear to the steel tube was guaranteed. The corbel behaved in a predictable way and supported high loads. The use of shear connectors in the column increased the load capacity and improved the connection performance. In next stage of the research work, two models were prepared, composed by: column, precast concrete beam, steel corbel and slabs constituting frames. In one of these models (model 4) a steel box was incorporated into the precast beam and bolted to the steel corbel in order to transfer the positive moments, whereas another model was built and studied without this device (model 3). In this models were evaluated the efficiency in the transfer of bending moments (positive and negative) and shear forces with the models subjected to a cyclic loads. In the model 3, the connection transferred efficiently the negative bending, but the performance for the positive bending was not satisfactory, with reduced strength and stiffness over the load cycles. In model 4 was observed considerable increase in strength and stiffness compared with the previous model. However, the device incorporated in the precast beam was unable to make the connection resist to the positive moments with the same efficiency observed when subjected to the negative moments and a degradation of their structural characteristics was observed during the loading cycles.

Page generated in 0.0576 seconds