1

Análise de prova de carga em tubulão a céu aberto submetido a esforço horizontal em solo não saturado de diabásio da região de Campinas / Analysis of static load test in the open pipe, subjected to horizontal stress in unsaturated diabasic soil of Campinas

Kassouf, Roberto, 1963- 21 August 2018 (has links)
Orientador: David de Carvalho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-21T12:02:47Z (GMT). No. of bitstreams: 1 Kassouf_Roberto_M.pdf: 4587745 bytes, checksum: 67d8f7ab10c6a6a1d4b0e8a2abdfa71e (MD5) Previous issue date: 2012 / Resumo: O problema de tubulões carregados horizontalmente no topo é freqüente em obras de construção civil e normalmente estes esforços horizontais atuam concomitantemente aos esforços verticais e momentos fletores onde os casos mais freqüentes são as ações dos ventos, torres de transmissão e para energia eólica, obras de arte como pontes e viadutos, muros de arrimo com o empuxo do solo, escavações para subsolo e edificações prediais, havendo uma reduzida bibliografia sobre os parâmetros a serem adotados em projeto. Uma hipótese mais critica é a de tubulões carregados horizontalmente em solos de alta porosidade, não saturados e colapsíveis. Os objetivos desta dissertação são: (1) proporcionar subsídios para o projeto de fundações com carregamento horizontal para tubulões, chamando a atenção para o danoso efeito de uma inundação de um solo colapsível; (2) fornecer valores do coeficiente de reação horizontal (nh), para uma argila siltosa arenosa de alta porosidade, solo de diabásio, comum na região de Campinas, para condição natural de umidade e solo pré-inundado; (3) comparar os valores obtidos com valores de (nh) com os propostos na bibliografia. Para a analise deste problema foi executado um tubulão em maciço de solo de formação de magmáticos básicos, ocorrendo rochas intrusivas básicas (Diabásios) da Formação Serra Geral, que faz parte do Grupo São Bento, característica do Campo Experimental de Fundações da UNICAMP/Campinas, com mais dois tubulões alinhados, estes servindo de reação ao sistema, todos executados a céu aberto e com base alargada, onde foram inseridos no eixo do tubulão a ser analisado, tubos para utilização de inclinomêtro e strain gages. As análises basearam-se nos resultados obtidos nas curvas de cargas versus deslocamento horizontais resultantes no topo e em profundidade através da utilização do inclinômetro / Abstract: The problem of caissons loaded horizontally at the top is common in construction work and normally these horizontal forces act concurrently with the vertical forces and bending moments where the most frequent cases are the actions of the winds, in towers for electric transmission and for wind energy, works of art as bridges and viaducts, retaining walls, underground excavations for buildings and there is a small literature on the parameters to be adopted in the project. One hypothesis, the most critical, is of caissons loaded horizontally in soils of high porosity, unsaturated and collapsible. The objectives of this dissertation are: (1) provide grants for the design of foundations with horizontal loading for caissons, calling attention to the damaging effect of a flood of a collapsible soil, (2) provide values of the coefficient of horizontal reaction (nh) to a sandy silty clay of high porosity, diabase soil, common in the region of Campinas, in the natural moisture content condition and in the pre-inundated soil condition, (3) compare the values obtained with the value (nh) with those proposed in the literature. For the analysis of this problem was carried out an caisson in a soil constituted by magmatic basic intrusive rocks (diabases) of the Serra Geral Formation, which is part of the São Bento Group, characteristic of the Experimental Foundations of Campinas / Campinas, aligned with two other caissons, serving as a reaction to these system, all running in the open and broad based, which were inserted into the pipe to be analyzed on its axis tubes for use with strain gages and inclinometer. The analyzes were based on the results of the load versus displacement curves obtained in the caisson head and in caisson shaft in depth / Mestrado / Geotecnia / Mestre em Engenharia Civil
2

Modelagem física de radiers estaqueados com e sem estacas defeituosas assentes em areia

Cordeiro, Ary Franck Baia 06 September 2017 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2017. / Submitted by Gabriela Lima (gabrieladaduch@gmail.com) on 2017-12-01T11:18:40Z No. of bitstreams: 1 2017_AryFranckBaiaCordeiro.pdf: 13320370 bytes, checksum: d29cc16e297ee2f8fd1f3b031788a9ce (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-01-25T14:55:25Z (GMT) No. of bitstreams: 1 2017_AryFranckBaiaCordeiro.pdf: 13320370 bytes, checksum: d29cc16e297ee2f8fd1f3b031788a9ce (MD5) / Made available in DSpace on 2018-01-25T14:55:25Z (GMT). No. of bitstreams: 1 2017_AryFranckBaiaCordeiro.pdf: 13320370 bytes, checksum: d29cc16e297ee2f8fd1f3b031788a9ce (MD5) Previous issue date: 2018-01-25 / O conceito de radier estaqueado vem sendo cada vez mais utilizado em fundações devido a ocorrência de prédios mais altos, que apresentam maiores cargas concentradas, mas também vem se tornando uma solução viável em pequenos empreendimentos. Desta forma, necessita-se de uma interação entre os elementos constituintes deste sistema para que se tenha um número ótimo de estacas sob o radier a fim de atender critérios de capacidade de carga e recalque admissível. Este aspecto é particularmente importante quando ocorrem defeitos (rupturas ou execução de estacas mais curtas que as projetadas) no sistema de fundação, que gera um fenômeno de distribuição de carga, mudança de fator de segurança e aumento de deslocabilidade imprevisível ao projetista. Um estudo aprofundado do assunto, em verdadeira grandeza, nem sempre é viável o que limita a avaliação destes sistemas sob condições de redução de escala em câmaras de calibração ou sob condições numéricas. Para esta tese de doutorado foram utilizadas placas rígidas e tubos de alumínio para realizar 20 provas de carga em escala reduzida com tensões de 1g assentes em areia sob carregamento vertical, controlados por célula de carga, com o intuito de avaliar o comportamento qualitativo (e prever tendências) de radiers estaqueados com e sem a presença de estacas danificadas para radiers estaqueados de 04, 09 e 16 estacas em tanque de ensaio cilíndrico metálico. Os danos foram simulados pela variação do comprimento das estacas (50%L e 0%L). Para os radiers de 09 e 16 estacas os danos variaram nas posições de canto, borda e centro da placa. Para os radiers sobre 04 estacas, com 25% de estacas danificas, na carga de serviço (50% da carga convencionada a um recalque de 10% do diâmetro da estaca) as fundações já estavam com FS de 1,5, enquanto que para os radiers sobre 09 (11% de dano) e 16 (6% de dano), os fatores de segurança atingiram 1,8 e 1,9, respectivamente. Observou-se também que, desde os níveis iniciais de carregamento, há uma pequena variação da rigidez do sistema, mesmo nos radiers de maior número de estacas, o que permite uma previsão qualitativa da nova situação pós defeito. E isso é claramente evidente a partir dos resultados que evidenciam a diminuição do fator de distribuição de carga (em um dado nível de recalque) com o aumento do número de estacas, embora estacas de diferentes comprimentos mostrem uma tendência similar na distribuição de carga. A tese contribui para o entendimento e a previsão qualitativa, adimensional, de sistemas de fundação radier estaqueado em condições distintas de defeito (posição, geometria do sistema, nível de deslocabilidade/carregamento), entendimento este que serve de base inicial a previsão do comportamento destas fundações quando fisicamente afetadas – e de certa forma à tomada de decisões sobre a eventual necessidade de reforço do sistema de fundações. / The concept of piled raft has been increasingly used in foundations due to the occurrence of taller buildings, which have higher concentrated loads, but has also become a economic solution in small building. In this way, an interaction between the constituent elements of this system is required in order to have an optimal number of piles under the raft in order to have a bearing capacity propered and admissible settlement. This is particularly important when defects occur (broken or execution of shorter piles than those designed) in the foundation system, occurs then a new behaviour of load spreads, change of safety factor and unplanned increase of displacement. An in-depth study of the subject in true scale is not always feasible which limits the evaluation of these systems small scale conditions in calibration chambers or under numerical conditions. For this work, therefore, rigid plates and aluminum tubes were used to carry out 20 load tests on small scale with 1g tension on sandy soil under vertical loading, controlled by a load cell, in order to evaluate the qualitative behavior (and predict trends) of piled raft with and without the presence of damaged pile for groups of 04, 09 and 16 piles in a cylindrical metallic test tank. The damages were simulated by the variation of the length of the intacts piles (50% L and 0% L). For the groups of 09 and 16 piles the damages varied in the corner positions, edge and center of the plate. For groups of 4 piles, with 25% of piles damaged, in the service load, the group already had SF of 1.5, while for the groups of 09 (11% damage) and 16 (6% damage), safety factors reached 1.8 and 1.9, respectively. It was also observed that, from the initial levels of loading, there is a small variation of the stiffness of the system, even in the groups with more piles, which allows a qualitative prediction of the new situation of post-defect. And this is clearly evident from the results that show the decrease in the load distribution factor (at a given displacement level) with the increase in the number of piles, although piles of different lengths show a similar tendency in the load spreads. This thesis contributes to the understanding qualitative form, dimensionless prediction of piled raft systems foundation under different conditions of defect (defective pile position, system geometry, level of displacement / loading), an understanding that serves as the initial basis for predicting the behavior of these foundations systems when physically affected - and to a certain extent to making decisions about the possible improve of the system.
3

Avaliação do comportamento de grupos de fundação carregados lateralmente em solo poroso colapsível e tropical do Distrito Federal

Abreu, José Antônio de 30 May 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil, 2014. / Submitted by Larissa Stefane Vieira Rodrigues (larissarodrigues@bce.unb.br) on 2014-12-09T19:21:13Z No. of bitstreams: 1 2014_JoséAntônioDeAbreu.pdf: 4206385 bytes, checksum: e7cea1206942a47a0d25ea44aed75cf2 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2014-12-10T11:26:13Z (GMT) No. of bitstreams: 1 2014_JoséAntônioDeAbreu.pdf: 4206385 bytes, checksum: e7cea1206942a47a0d25ea44aed75cf2 (MD5) / Made available in DSpace on 2014-12-10T11:26:13Z (GMT). No. of bitstreams: 1 2014_JoséAntônioDeAbreu.pdf: 4206385 bytes, checksum: e7cea1206942a47a0d25ea44aed75cf2 (MD5) / Neste trabalho, objetivou-se ampliar o entendimento a respeito do efeito de grupo, na capacidade de carga e na relação carga-deflexão de grupo de estacas, submetido a carregamento lateral, assente em argila porosa colapsível, a partir da análise de provas de carga existentes de grupo de duas e três estacas e uma prova de carga na estaca isolada para comparar com o comportamento dos grupos de estacas. As provas de carga foram realizadas com o solo na condição de umidade natural e, em seguida, as mesmas estacas foram reensaiadas com o solo pré-inundado por 48 horas. A partir de métodos analíticos, fez-se a previsão da capacidade de carga da estaca isolada, a qual teve razoável concordância com a carga última definida na prova de carga pelo critério da ruptura convencional. Também se avaliou a influência da colapsividade sobre o comportamento do grupo de estacas comparando-se com o comportamento da estaca isolada. Por meio da retroanálise da prova de carga, calculou-se a constante do coeficiente de reação horizontal do solo (ηh) e o módulo de Young do solo (Es). Utilizou-se o método da estaca equivalente ao grupo (GEP) para analisar o comportamento carga versus deflexão do grupo de estacas através do software comercial LPILE Plus V. 5.0, que possibilitou avaliar a influência da rigidez flexional sobre o comportamento das estacas e retroanalisar o fator de eficiência do grupo de três estacas. Por último, são sugeridos procedimento de análise e dimensionamento de grupo de estacas. _______________________________________________________________________________________ ABSTRACT / This work, has aim to expand understanding of the effect of group, load capacity and load-deflection relationship of group piles subjected to lateral loading, on collapsible porous clay, from the analysis of load tests in the group of two and three piles and a load test on single pile which provided a comparison with the behavior of groups of piles . The load tests were made with the ground at the natural humidity condition and then retest the same piles with pre-flooded soil for 48 hours. From analytical methods became predicting the load capacity of the pile isolated which had reasonable agreement with the last defined load on the load test by conventional criterion of rupture, assessed the influence of colapsividade on the group behavior of piles comparing behavior with single pile. Through back analysis of load test, we calculated the constant coefficient of horizontal soil reaction (ηh) and Young's modulus of the soil (Es). We used the method of the pile equivalent group (GEP) to analyze the load versus deflection behavior of the group of pile through LPILE Plus V. 5.0 commercial software, which allowed us to evaluate the influence of flexural stiffness on the behavior of the group of piles and back analysis the efficiency factor of the group of three piles. Lastly are suggested procedure for analysis and design of group piles.
4

Prova de carga dinâmica em placa / Dynamic load plate test

Moraes, Luciene Santos de 31 May 2005 (has links)
A prova de carga dinâmica é freqüentemente utilizada na determinação da capacidade de carga de fundações por estacas cravadas e há relatos de uso com sucesso deste ensaio em estacas escavadas e tubulões. Esta pesquisa envolveu a adaptação e execução da prova de carga dinâmica na placa de aço circular de diâmetro 0,80 m, com o objetivo de inferir a capacidade de carga do sistema placa-solo. Como a prova de carga dinâmica permite que seja feita a comprovação da carga durante a cravação, vislumbra-se também a viabilização desse tipo de ensaio em solos porosos por meio da cravação da placa o necessário para atingir a capacidade de carga exigida em um projeto. Os ensaios foram realizados no campo experimental da USP/São Carlos, com solo superficial não saturado, poroso e colapsível, por isso foram feitas medidas dos valores de sucção matricial, já que esta exerce forte influência sobre a capacidade de carga / The dynamic load test is frequently used in the determination of driven piles foundation bearing capacity. It is also reported the successful use of the test in bored piles and caissons. This research included the adaptation and execution of the dynamic load test in circular steel plate, to verify the bearing capacity of footing foundations. Since the dynamic load tests allow the bearing capacity to be verified during the construction, it is also glimpsed the possibility of using this test in porous soils by penetrating the plate into the soil until the expected bearing capacity is achieved. The tests were held at the USP/São Carlos experimental foundation camp, which has superficial unsaturated, porous and colapsive soil, so matric suction's measurement were made, since it has strong influence on the bearing capacity
5

Prova de carga dinâmica em placa / Dynamic load plate test

Luciene Santos de Moraes 31 May 2005 (has links)
A prova de carga dinâmica é freqüentemente utilizada na determinação da capacidade de carga de fundações por estacas cravadas e há relatos de uso com sucesso deste ensaio em estacas escavadas e tubulões. Esta pesquisa envolveu a adaptação e execução da prova de carga dinâmica na placa de aço circular de diâmetro 0,80 m, com o objetivo de inferir a capacidade de carga do sistema placa-solo. Como a prova de carga dinâmica permite que seja feita a comprovação da carga durante a cravação, vislumbra-se também a viabilização desse tipo de ensaio em solos porosos por meio da cravação da placa o necessário para atingir a capacidade de carga exigida em um projeto. Os ensaios foram realizados no campo experimental da USP/São Carlos, com solo superficial não saturado, poroso e colapsível, por isso foram feitas medidas dos valores de sucção matricial, já que esta exerce forte influência sobre a capacidade de carga / The dynamic load test is frequently used in the determination of driven piles foundation bearing capacity. It is also reported the successful use of the test in bored piles and caissons. This research included the adaptation and execution of the dynamic load test in circular steel plate, to verify the bearing capacity of footing foundations. Since the dynamic load tests allow the bearing capacity to be verified during the construction, it is also glimpsed the possibility of using this test in porous soils by penetrating the plate into the soil until the expected bearing capacity is achieved. The tests were held at the USP/São Carlos experimental foundation camp, which has superficial unsaturated, porous and colapsive soil, so matric suction's measurement were made, since it has strong influence on the bearing capacity
6

Estacas escavadas com base injetada / Injected toe bored piles

Moraes, Luciene Santos de 19 July 2010 (has links)
Foram construídas bases injetadas próximas à superfície e estacas escavadas com base injetada no campo experimental de fundações do departamento de geotecnia da USP/São Carlos. As injeções de caldas de cimento portland foram realizadas como procedimento de melhoria do solo de apoio. Provas de carga estática em estruturas com e sem injeção determinaram a eficácia da solução de bases injetadas. Simultaneamente às provas de carga, houve monitoração da sucção matricial atuante no solo, dando continuidade ao extenso programa de pesquisa realizado no Campo Experimental de Fundações da USP/São Carlos no tema da colapsibilidade. / Injected elements close to surface and toe injected bored piles were built at USP/São Carlos experimental foundation field. Under the foundations, portland cement grout was injected in order to improve soil and foundation bearing capacity. Load tests measured and determined the efficacy of the solution. Along with the load tests, matric suction measurements were made, continuing the extensive research program in the USP/São Carlos experimental foundation field under the theme soil collapsibility.
7

Estacas escavadas com base injetada / Injected toe bored piles

Luciene Santos de Moraes 19 July 2010 (has links)
Foram construídas bases injetadas próximas à superfície e estacas escavadas com base injetada no campo experimental de fundações do departamento de geotecnia da USP/São Carlos. As injeções de caldas de cimento portland foram realizadas como procedimento de melhoria do solo de apoio. Provas de carga estática em estruturas com e sem injeção determinaram a eficácia da solução de bases injetadas. Simultaneamente às provas de carga, houve monitoração da sucção matricial atuante no solo, dando continuidade ao extenso programa de pesquisa realizado no Campo Experimental de Fundações da USP/São Carlos no tema da colapsibilidade. / Injected elements close to surface and toe injected bored piles were built at USP/São Carlos experimental foundation field. Under the foundations, portland cement grout was injected in order to improve soil and foundation bearing capacity. Load tests measured and determined the efficacy of the solution. Along with the load tests, matric suction measurements were made, continuing the extensive research program in the USP/São Carlos experimental foundation field under the theme soil collapsibility.
8

Avaliação dos métodos de previsão e controle de capacidade de carga em estacas tipo perfil metálico “H”

Inácio da Silva, Leandro 31 January 2013 (has links)
Submitted by Romulus Lima (romulus.lima@ufpe.br) on 2015-03-10T13:53:40Z No. of bitstreams: 2 Dissertação Leandro Inacio da Silva.pdf: 10343622 bytes, checksum: c57f859f206fc18bfb4d6b53cb664f29 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-10T13:53:40Z (GMT). No. of bitstreams: 2 Dissertação Leandro Inacio da Silva.pdf: 10343622 bytes, checksum: c57f859f206fc18bfb4d6b53cb664f29 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2013 / CAPES / O presente trabalho avalia a capacidade de carga obtida através de diversos métodos: semiempíricos (Aoki-Velloso (1975), Décourt-Quaresma (1978, 1982) e de Teixeira (1996)); métodos dinâmicos (Fórmulas de Brix, Holandeses, Velloso (1987), Rosa (2000) e Uto et al (1985)) para 25 estacas metálicas perfil “H”, através de ensaios de carregamento dinâmicos de energia crescente (programa CASE e CAPWAP) e prova de carga estática. As estacas foram executadas em uma edificação localizada em Paulista-PE. Os resultados obtidos pelos métodos semiempíricos apresentaram comportamento conservador quando comparados com os resultados de ensaio de carregamento dinâmico e prova de carga estática, sendo o método de Aoki-Velloso (1975) o que teve melhor aproximação. As fórmulas dinâmicas com base nos dados de nega mostraram-se extremamente conservadoras na estimativa da capacidade de carga, diferente dos resultados obtidos das fórmulas com base no repique elástico que apresentaram resultados com boa correlação. Em relação aos resultados obtidos pelo programa CASE e os obtidos em provas de carga estática mostram que a depender das circunstâncias, o ensaio de carregamento dinâmico pode superestimar a capacidade de carga.
9

Análise de provas de carga dinâmica em tubulões a céu aberto no campo experimental de fundações da EESC/USP / Analysis of dynamic loading test in large diameter bored piles, in the experimental field of EESC

Soares, Fábio Lopes 13 March 2003 (has links)
Apresenta-se o conceito de elemento isolado de fundação em tubulão, e analisa-se 10 provas de carga dinâmica de energia crescente, nos tubulões, considerando as provas de carga estática realizadas anteriormente nos mesmos. Os ensaios são realizados em tubulões a céu aberto, situados em maciço de solo da formação Rio Claro e Itaqueri, no campo experimental de fundações da USP/EESC. As análises baseiam-se em curvas de resistência x deslocamento e gráficos que mostram a evolução da resistência mobilizada com o aumento da energia aplicada, resultantes dos impactos do ensaio dinâmico de energia crescente (metodologia PDA e análises CAPWAP). Analisam-se também a influência da pré-inundação e da variação da sucção do maciço de solos nos ensaios dinâmicos, o efeito do reensaio e a variabilidade nos resultados de ensaios de investigação geotécnica (SPT e CPT), realizados no campo experimental. Os resultados das provas de carga dinâmica de energia crescente mostram que a resposta do sistema isolado de fundação em tubulão é diferente a cada nível de energia aplicada e que a história de carregamento do elemento isolado de fundação é de extrema importância para análise dos ensaios nele realizado. / The concept of an isolated foundation element in large diameter bored pile is presented and 10 dynamic loading tests with increased energy are analysed. The interpretation of the dynamic loading tests has been proceeded with due consideration of the results of static loading tests performed previously. The loading tests have been carried out in large diameter bored piles founded in Rio Claro and Itaqueri soil formation, situated in the experimental foundation field of USP/EESC. The analyses are based on resistance x displacement curves and selected graphics illustrating the development of mobilized resistance with increasing applied energy during a dynamic loading test (PDA methodology and CAPWAP type analysis). The influence of previous inundation in soil mass and suction variation are also analysed, as well as the effect of test repetition and variability in SPT and CPT results. The results obtained with the dynamic loading tests with increasing energy revealed a distinct behaviour of the isolated foundation system for each level of applied energy, showing that the loading history is an aspect of extreme relevance to an adequate analysis of the dynamic tests perfomed.
10

Análise de provas de carga dinâmica em tubulões a céu aberto no campo experimental de fundações da EESC/USP / Analysis of dynamic loading test in large diameter bored piles, in the experimental field of EESC

Fábio Lopes Soares 13 March 2003 (has links)
Apresenta-se o conceito de elemento isolado de fundação em tubulão, e analisa-se 10 provas de carga dinâmica de energia crescente, nos tubulões, considerando as provas de carga estática realizadas anteriormente nos mesmos. Os ensaios são realizados em tubulões a céu aberto, situados em maciço de solo da formação Rio Claro e Itaqueri, no campo experimental de fundações da USP/EESC. As análises baseiam-se em curvas de resistência x deslocamento e gráficos que mostram a evolução da resistência mobilizada com o aumento da energia aplicada, resultantes dos impactos do ensaio dinâmico de energia crescente (metodologia PDA e análises CAPWAP). Analisam-se também a influência da pré-inundação e da variação da sucção do maciço de solos nos ensaios dinâmicos, o efeito do reensaio e a variabilidade nos resultados de ensaios de investigação geotécnica (SPT e CPT), realizados no campo experimental. Os resultados das provas de carga dinâmica de energia crescente mostram que a resposta do sistema isolado de fundação em tubulão é diferente a cada nível de energia aplicada e que a história de carregamento do elemento isolado de fundação é de extrema importância para análise dos ensaios nele realizado. / The concept of an isolated foundation element in large diameter bored pile is presented and 10 dynamic loading tests with increased energy are analysed. The interpretation of the dynamic loading tests has been proceeded with due consideration of the results of static loading tests performed previously. The loading tests have been carried out in large diameter bored piles founded in Rio Claro and Itaqueri soil formation, situated in the experimental foundation field of USP/EESC. The analyses are based on resistance x displacement curves and selected graphics illustrating the development of mobilized resistance with increasing applied energy during a dynamic loading test (PDA methodology and CAPWAP type analysis). The influence of previous inundation in soil mass and suction variation are also analysed, as well as the effect of test repetition and variability in SPT and CPT results. The results obtained with the dynamic loading tests with increasing energy revealed a distinct behaviour of the isolated foundation system for each level of applied energy, showing that the loading history is an aspect of extreme relevance to an adequate analysis of the dynamic tests perfomed.