• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 614
  • 24
  • 10
  • 7
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 670
  • 424
  • 152
  • 94
  • 89
  • 87
  • 86
  • 82
  • 66
  • 66
  • 65
  • 62
  • 59
  • 59
  • 57
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
331

Estudo da influência de partículas de ouro na dose absorvida em tecido mole utilizando dosimetria com gel polimérico / Study of the influence of gold particles on the absorbed dose in soft tissue using polymer gel dosimetry

Luciana Caminha Afonso 04 October 2011 (has links)
A presença de material de alto número atômico adjacente ao tecido mole aumenta localmente a dose absorvida pelo tecido quando submetido à radiação. Este efeito ocorre devido aos fotoelétrons ejetados do material de alto número atômico. Dosímetros de gel polimérico com partículas de ouro foram utilizados para investigar este efeito. Foram realizados cálculos analíticos para estimar o aumento de dose e simulações com o método de Monte Carlo. A irradiação de amostras de gel polimérico (GP) puro e com 0,005 gAu/gGP utilizando um feixe de raios X produzido por um potencial de 150 kV filtrado com 4 mmAl e 5 mmCu resultou em uma dose absorvida pelas amostras com ouro aproximadamente 20% maior que a dose absorvida pelas amostras de gel polimérico puro. Os cálculos analíticos e a simulação com o método de Monte Carlo resultaram em um aumento de aproximadamente 30% na dose absorvida. / The presence of high-Z material adjacent to soft tissue, when submitted to irradiation, enhances locally the absorbed dose in these soft tissues. Such effect occurs due to the outscattering of photoelectrons from the high-Z material. Polymer gel dosimeters have been used to investigate this effect. Analytic calculations to estimate the dose enhancement and Monte Carlo simulations have been performed. Samples containing polymer gel (PG) with 0.005 gAu/gPG and pure polymer gel have been irradiated using an X-rays beam produced by 150 kV, filtered with 4 mm Al and 5 mm Cu, which resulted in an approximately 20% higher absorbed dose in the samples with gold in comparison to those with pure polymer gel. The analytic calculations and the Monte Carlo simulation resulted in a dose enhancement factor of approximately 30%.
332

Caracterização de dosímetros semicondutores e suas aplicações em técnicas especializadas em radioterapia / Characterization of Semiconductors Dosimeters and their Applications in Specialized Techniques in Radiation Therapy.

Oliveira, Fernanda Ferretti de 21 December 2012 (has links)
Introdução: A Radioterapia é frequentemente utilizada no tratamento do câncer, seja como uma modalidade simples ou em combinação com outras modalidades, tais como a cirurgia e a quimioterapia. Com o objetivo de eliminar células não desejadas no organismo humano, utiliza-se de radiações ionizantes para provocar a destruição de células tumorais pela absorção da energia da radiação incidente. A principal dificuldade encontrada em radioterapia é que as células tumorais não são tratadas isoladamente, isto é, o dano da radiação não é restrito somente às células tumorais, mas afeta também as células normais. Assim sendo, é essencial que a dose de radiação liberada nos tecidos normais seja tão baixa quanto possível para minimizar o risco de efeitos colaterais provocados pelos tratamentos radioterápicos. Objetivos: O objetivo deste trabalho é a caracterização de dosímetros semicondutores e dosímetros termoluminescentes e suas aplicações em técnicas não convencionais de Radioterapia. A partir da caracterização será possível a implementação dos dosímetros como sistema de dosimetria in vivo em teleterapia com feixe de fótons, visando atender as necessidades prementes do Serviço de Radioterapia do HCFMRP em implantar a técnica de irradiação de corpo inteiro e em realizar o controle de dose administrada ao paciente. Metodologia e Resultados: Diodos semicondutores foram caracterizados de acordo com o fator campo, angulação, taxa de dose, temperatura e fator bandeja, para obtenção dos fatores de correção. Verificou-se que a variação da resposta dos diodos com a temperatura, angulação e taxa de dose não foi significativa. Fatores campo foram calculados e registrados para campos de 3x3 cm 2 a 40x40cm 2 , onde se observou aumento na leitura do diodo com o aumento no campo. A resposta com a taxa de dose apr esentou pouca variação (de 100cGy/min para 300cGy/min a variação foi menor que 1,2%). O fator bandeja encontrado foi de 0,95±0,01 demonstrando que a presença da bandeja provoca diminuição na resposta do detector. Após a caracterização, os diodos foram calibrados em setup TBI para determinação dos fatores de calibração para cada espessura simulada do paciente (DLL). A dosimetria in vivo foi realizada em 3 pacientes submetidos ao tratamento de TBI do HCFMRP. A diferença percentual máxima entre as medidas com diodo e o valor nominal de dose foi de 3,6%, o que está de acordo com o recomendado pelo ICRU (+/- 5%). Os resultados demonstram a viabilidade e confiabilidade da técnica de dosimetria com diodos semicondutores para Controle de Qualidade de dose em tratamento de TBI. Ainda, dosímetros termoluminescentes foram caracterizados quanto à homogeneidade do grupo e a linearidade. Os fatores de calibração individuais foram encontrados e os dosímetros foram aplicados em simulações em setup TBI. Os cálculos de dose das simulações realizadas com os termoluminescentes inseridos nos orifícios de um OSA demonstraram concordância com os valores nominais de dose. Para as regiões do tórax superior e inferior, onde os TLD receberam doses mais elevadas (>150cGy), recomendou-se a utilização de compensadores de dose, para a prática clínica.Uma câmara de ionização foi utilizada como dosímetro de referência em todas as etapas de calibração e caracterização dos diodos e termoluminescentes. Conclusões: Este estudo mostrou que, para tratamentos de irradiação de corpo inteiro, quando o paciente estiver sendo preparado para um transplante de medula óssea, e o planejamento necessitar de uma grande eficácia na distribuição de dose, a metodologia com aplicações de dosímetros semicondutores apresenta-se como uma alternativa viável, precisa e de grande importância para o controle dosimétrico. Assim, ficou evidenciada a importância da utilização do diodo para o Controle de Qualidade, na avaliação da dos e a ser ministrada ao paciente, pelo menos em toda primeira fração de tratamento de TBI. Além disso, ficou demonstrada a aplicabilidade dos dosímetros termoluminescentes para controle dosimétrico, demonstrando o valor da dosimetria termoluminescente como um sistema de verificação de dose e sua eficácia como parte de um programa de garantia de qualidade em Radioterapia. A caracterização dos termoluminescentes evidenciou a possibilidade de aplicação da técnica TL em dosimetria in vivo. / Introduction: Radiation therapy is often used in cancer treatment, either as a single modality or in combination with other modalities, such as surgery and chemotherapy. Aiming to eliminate unwanted cells in the human body, radiation therapy uses ionizing radiation to cause destruction of tumor cells by absorbing the energy of the incident radiation. The main difficulty in radiation therapy is that tumor cells are not separately treated. The radiation damage is not restricted solely to tumor cells, but also affects normal cells. Therefore, it is essential that the radiation dose released in normal tissues is as low as possible to minimize the risk of side effects caused by radiotherapy treatments. Objectives: The objective of this work is the characterization of semiconductor dosimeters and thermoluminescent dosimeters and their applications in non -conventional radiotherapy techniques. After characterization it will be possible to implement the dosimeters as a system of in vivo dosimetry in radiotherapy with photon beam, to meet the pressing needs of the Radiotherapy Service of HCFMRP in deploying the technique of total body irradiation and make the control of dose administered to the patient . Methodology and Results: Semiconductor diodes were characterized according to the field factor, angle, dose rate, temperature and tray factor to obtain the correction factors. It was found that the variation of the response of the diodes with temperature, angle and dose rate was not significant. Field factors were calculated and recorded for fields from 3x3 cm 2 to 40x40cm 2 , wher e there was an increase in the reading of the diode with increasing field. The response with dose rate showed small variation (from 100cGy/min to 300cGy/min the variation was less than 1.2%). The tray factor was 0.95 ± 0.01 demonstrating that the tray decreases detector response. After characterization, the diodes were calibrated in TBI setup for determining the calibration factors for each simulated patient thickness (latero-lateral distance). The in vivo dosimetry was performed in 3 patients undergoing TBI treatment in HCFMRP. The maximum percentage difference between the measurements and the diode nominal dose was 3.6%, which is consistent with that recommended by ICRU (+ / - 5%). The results demonstrate the feasibility and reliability of the dosimetry technique with semiconductor diodes for dose quality control in TBI treatments. Still, dosimeters were characterized by group homogeneity and linearity. The calibration factors were found and individual dosimeters were applied in simulations with TBI setup. The dose calculation of simulations performed with the thermoluminescent inserted in holes of the phantom showed agreement with the nominal dose. For regions of the upper and lower thorax where TLD received higher doses (> 150cGy) it was recommended the use of compensating dose in clinic. An ionization chamber dosimeter was used as reference in all stages of calibration and characterization of diodes and thermoluminescents. Conclusions: This study showed that, for total body irradiation treatments, when the patient is being prepared for a bone marrow transplant, and planning requires a great effect on the dose distribution, the methodology with semiconductor dosimeters presented a viable alternative, and has great importance for the dosimetric control. The study proved the importance of diode semiconductors for quality control, for evaluation of the dose to be administered to the patient, at least throughout the first fraction of TBI treating. Furthermore, it was demonstrated the applicability of TLD for control quality, demonstrating the value of thermoluminescent dosimetry as a dose verification system and its effectiveness as part of a program of quality assurance in radiotherapy. The characterization of thermoluminescent showed the possibility of applying the TL technique in in vivo dosimetry.
333

Avaliação de distribuições de dose em tratamentos radioterápicos utilizando filmes radiocrômicos / Evaluation of dose distribution in radiotherapy using radiochromic films.

Marini, Gislaine 15 August 2013 (has links)
O sucesso do tratamento de neoplasias depende da precisão na localização tumoral e de áreas críticas limítrofes, e da distribuição da dose entregue a esses volumes. O objetivo deste trabalho foi verificar a utilização do filme radiocrômico Gafchromic R EBT2 na avaliação da distribuição de dose em planejamentos radioterápicos, desenvolvendo um protocolo dosimétrico capaz de verificar a conformidade entre distribuições de doses planejada e entregue em teleterapia. Avaliou-se também, a contribuição da separação dos canais RGB das imagens para o controle da qualidade dos planejamentos utilizando esses filmes. Com esse intuito, realizou-se testes para verificação das características do filme EBT2 e do digitalizador a fim de obter-se um protocolo dosimétrico adequado. Realizou-se a simulação de tratamentos de sistema nervoso central com a irradiação de um objeto simulador homogêneo, com 5 campos em um acelerador linear de 6 MV e comparou-se com os dados do sistema de planejamento através de mapas de índice gama. Observou-se que o canal verde, apresenta maior conformidade aos valores de referência. Os mapas de índice gama, resultaram em uma conformação de 98% para critérios de aceitação de DD = 3 % e DTA = 3 mm, de acordo com os limites estabelecidos no Report 62 do ICRU. Ao final deste trabalho, concluiu-se que o protocolo estabelecido com a análise do canal verde no filme EBT2 é adequado para a realização do controle da qualidade em tratamentos conformacionais, sendo uma ferramenta de fácil implementação para avaliação da distribuição de dose nesses tratamentos. / The successful treatment of neoplasms depends on the accurate localization of the tumor and adjacent critical areas, and the distribution of the dose delivered to these volumes. The objective of this work was to verify the use of radiochromic film Gafchromic R EBT2 to evaluate the dose distribution in radiotherapy planning, developing a dosimetric protocol able to check the conformity between the planned and delivered dose distributions in teletherapy. The contribution of the RGB channel separation in the images to quality control of the planning was also evaluated. With this purpose, EBT2 film was calibrated and studied to verify its characteristics when read with a scanner in order to obtain a suitable dosimetric protocol. Simulation in a homogeneous phantom with 5 radiation fields on a 6 MV linear accelerator was compared with the planning system data through gamma index maps. It was observed that the green channel has a higher conformity with the reference values. The gamma index maps resulted in a conformation of 98% when the acceptance criteria was DD = 3% and DTA = 3 mm, according to the limits established by the ICRU Report 62. This study concluded that the protocol established for the analysis EBT2 films with green channel is suitable for performing quality control in conformational treatments.
334

Repercussões tardias da radioterapia sobre a função pulmonar em pacientes com câncer de mama / Long-term pulmonary effects of radiotherapy detected by pulmonary function in breast cancer patients

Gomide, Liana Barbaresco 17 November 2006 (has links)
A realização de radioterapia adjuvante no tratamento do câncer de mama está comumente associada com complicações pulmonares em curto prazo, mas é questionável se essas alterações podem estar presentes também ao longo do tempo. Este trabalho teve como objetivo avaliar, em mulheres que foram diagnosticadas com câncer de mama, o comportamento da função pulmonar e a presença de dispnéia 18 meses após o término da radioterapia. Para tanto, foi realizado um estudo caso-controle em um grupo de 40 voluntárias não tabagistas e sem doenças cardiorrespiratórias que foram divididas em: irradiadas e controle. No grupo irradiado foram incluídas pacientes que realizaram tratamento conservador para o câncer de mama e que receberam radioterapia adjuvante. No grupo controle participaram voluntárias saudáveis com características físicas, etárias e antropométricas semelhantes ao grupo irradiado. Os parâmetros da função pulmonar como volumes (inclusive residual), capacidade vital forçada, fluxos expiratórios máximos e capacidade de difusão foram obtidos por meio do espirômetro GS Plus da Collins. O sintoma de dispnéia em pacientes irradiadas foi quantificado pela escala de dispnéia do Conselho Britânico de Pesquisas Médicas (MRC). As pacientes que realizaram radioterapia apresentaram valores de CPT, CV, CVF e VEF1 (em percentual do previsto) significativamente menores (p<0,05) que os valores correspondentes obtidos pelas voluntárias controle. Observamos ainda, uma tendência dos parâmetros da função pulmonar diminuírem à medida que o grau de dispnéia aumentava. As pacientes com dispnéia grau 2, apresentaram valores de CV, CVF e VEF1 (em percentual do previsto) significativamente menores que as pacientes que não relataram dispnéia. A detecção de alterações da função pulmonar em fases tardias de pacientes submetidas à radioterapia reforça a necessidade de seguimento longitudinal prolongado pré e pós-procedimento. / Adjuvant radiotherapy for breast cancer is commonly associated with short-term pulmonary complications. Long-term risks of this regimen are, however, still debated. The aim of this study was to evaluate dyspnea and pulmonary function 18 months after radiotherapy in breast cancer patients. The population studied consisted of 40 nonsmoking subjects free of cardiorespiratory disease separate divided in two groups: irradiated and control. In the irradiated group they were included patient that undergone breast-conserving surgery and adjuvant radiotherapy and in the group control healthy subjects with age, height and weight similar to the irradiated group. Pulmonary function parameters as volumes (including residual volume), forced vital capacity, maximum expiratory flow and lung capacity diffusion were obtained through GS Plus Collins spirometer. Dyspnea in the irradiated patients was quantitated by the Medical Research Council (MRC) dyspnea scale. Patients that undergone radiotherapy had values of TLC, VC, FVC and FEV1 (as percent predicted) that were significantly less (p <0,05) than corresponding values for the control subjects. Lung function parameters trended downward as the dyspnea score increased. Patients with level 2 dyspnea, had values of VC, FVC and FEV1 (as percent predicted) that were significantly less than corresponding values for the level 0 dyspnea patients. Changes in pulmonary function detected a long term after radiotherapy in breast cancer patients intensify the achievement follow-up study before and after long term treatment with radiotherapy.
335

Estudos dos efeitos tardios do tratamento antineoplásico sobre as estruturas dentárias e ósseas na infância / Study of late effects of antineoplastic treatment on dental and bone structures in childhood

Quispe, Reyna Aguilar 27 March 2018 (has links)
A sobrevida de crianças que foram submetidos a tratamento antineoplásico tem se acrescentado nos últimos anos devido às novas alternativas de tratamento. Os sobreviventes de câncer infantil com frequência podem apresentar efeitos tardios decorrentes do tratamento antineoplásico. Diferentes órgãos podem apresentar efeitos tardios incluindo os dentes. Algumas anomalias dentárias são associadas aos efeitos da quimioterapia e/ou radioterapia. O estudo da influência do tratamento antineoplásico sobre a ocorrência de anomalias dentárias, permite saber quais os possíveis desafios no tratamento odontológico nos sobreviventes de câncer infantil. Este estudo, avaliou as anomalias dentárias e a idade dentária através de radiografias panorâmicas em sobreviventes de câncer infantil e compará-la com radiografias panorâmicas de indivíduos saudáveis. Foram avaliadas 111 radiografias panorâmicas de sobreviventes de câncer infantil comparadas a 111 radiografias panorâmicas de indivíduos saudáveis pareadas por idade e gênero respeito ao grupo de estudo, com análise de tipo duplo cego. Foram avaliadas um total de 16 tipos de anomalias dentárias de forma, tamanho, número assim como anomalias do desenvolvimento da raiz dentária classificadas em 5 tipos diferentes. A idade dentária foi avaliada pelo método de Demirjiam. A microdontia, hipodontia e anomalias do desenvolvimento da raiz foram as anomalias dentárias que apresentaram maior ocorrência nos sobreviventes de câncer da infância quando comparado a indivíduos saudáveis (p=<0,05). A microdontia esteve associada à idade de diagnóstico menor a 5 anos de idade (p=<0,04). O dente não irrompido teve associação com indivíduos que foram submetidos a quimioterapia concomitante com radioterapia (p=<0,001). Anomalias dentárias com uma quantidade >10 estiveram presentes somente no grupo de estudo. A idade dentária não apresentou diferença significativa entre os grupos (p=>0,05). Conclui-se que Indivíduos submetidos a quimioterapia e/ou radioterapia durante a infância apresentaram maior ocorrência de desenvolver anomalias dentárias. Porém, a idade dentária sugere não ser afetada pela quimioterapia e/ou radioterapia. / Children who have been undergone antineoplastic treatment have increased the survival due to new treatment alternatives. The childhood cancer survivors may have frequently late effects from antineoplastic treatment. Different organs may have late effects including the teeth. Some dental anomalies are associated as late effects of chemotherapy and/or radiotherapy. To study the antineoplastic treatment influence on the occurrence of dental anomalies allows to know the possible challenges in dental care of childhood cancer survivors. This study evaluated dental abnormalities and the dental maturity by panoramic radiographs in childhood cancer survivors and to compare it with panoramic radiographs of healthy individuals. A total of 111 panoramic radiographs of childhood cancer survivors compared to 111 panoramic radiographs of healthy individuals were evaluated. They were matched for age and gender regarding the childhood cancer survivor, with a double-blind type analysis. A total of 16 types of dental anomalies of shape, size, number and developmental anomalies of the dental root were classified into 5 different types. Dental maturity was assessed by the Demirjian method. Microdontia, hypodontia, and root anomalies were the dental anomalies that presented a higher prevalence in CCS when compared to healthy individuals (p = <0.05). Microdontia was associated with a diagnosis age younger than 71 months of age (p = <0.04). The impacted tooth was associated with individuals who underwent chemotherapy concomitantly with radiotherapy (p <0.001). Individuals with an amount of 10 or > 10 dental anomalies were present only in the CCS group. Dental maturity did not present a significant statistical difference between CCS and healthy individuals. It was concluded that individuals undergoing chemotherapy and/or radiotherapy during childhood had a higher prevalence of dental. However, dental maturity suggests that it is not affected by chemotherapy and/or radiotherapy.
336

Definição do volume de planejamento do alvo (PTV) e seu efeito na radioterapia / Planning target volume (PTV) definition and its effects in the radiotherapy

Poli, Maria Esmeralda Ramos 28 May 2007 (has links)
Este trabalho visa estudar as margens necessárias para definir o volume de planejamento do alvo (PTV) requeridas para tratar adequadamente tumores móveis como os localizados na próstata ou tumores localizados em áreas com pouca mobilidade como os da região da cabeça e pescoço, na ausência de localização do alvo por imagem. Também tem como objetivo avaliar o impacto causado pelo PTV, em termos de dose, nas estruturas críticas ao seu redor e sua influência quando planejamento inverso é utilizado na radioterapia com modulação de feixe (IMRT). Dados de 387 pacientes de próstata foram analizados retrospectivamente. Todos os pacientes receberam localização pré-tratamento com ultra-som 2D resultando em 10.327 localizações, cada uma com deslocamento de isocentro em três direções: antero-posterior (AP), lateral direitaesquerda (DE), e superior-inferior (SI). O deslocamento médio e desvio padrão (SD) para cada direção foi estimado a partir dos dados de tratamento gravados diariamente. As incertezas (SD) na posição do alvo foram 4,4 mm (AP), 3,6 mm (DE), e 4,5 mm (SI). O estudo das incertezas no posicionamento diário de 78 pacientes com tumores de cabeça e pescoço que utilizaram máscaras termoplásticas como imobilizadores, avaliados com equipamento de portal com imagem eletrônica (EPID), mostrou variações (SD) na posição do isocentro de tratamento de 3,1 mm (AP), 1,5 mm (DE), 4,5 mm (SI). Aplicando estes desvios num simulador antropomórfico estudou-se os histogramas de dose-volume resultantes do deslocamento do isocentro no tratamento diário. Os resultados mostraram a importância de se colocar margens no volume clínico do alvo para garantir um tratamento adequado e também mostraram que a variação diária do isocentro de tratamento pode causar um aumento de dose maior que o nível de tolerância dos órgãos críticos. / This work intends to study the margins required to define a planning target volume (PTV) for adequate treatment of the mobile tumors such as prostate or those located in areas with less mobility as the ones in head and neck region, in the absence of daily localization imaging based. It is also intends to evaluate the impact caused by the PTV, in terms of dose, to the critical structures surrounding the PTV and its influence when inverse planning is used in the intensity-modulated radiation therapy (IMRT). Data from 387 prostate patients were analyzed retrospectively. Every patient in the study received daily pre-treatment localization with 2D ultrasound resulting in a total of 10,327 localizations, each comprising of an isocenter displacement in 3 directions: anterior-posterior (AP), right-left lateral (RL), and superior-inferior (SI). The mean displacement and standard deviation (SD) for each direction for each patient was computed from daily treatment records. The uncertainties (SD) in the target position were 4.4 mm (AP), 3.6 mm (RL), and 4.5 mm (SI). A study of the uncertainties in the daily positioning of 78 head and neck patients who used thermoplastic mask to immobilize them, evaluated with electronic portal imaging device (EPID), showed variations (SD) in the isocenter treatment position of 3.1 mm (AP), 1.5 mm (RL), and 4.5 mm (SI). By applying these shifts in an anthropomorphic phantom it was studied the dose-volume histograms resultant of the isocenter displacement in the daily treatment. The result showed the importance of putting margins in the clinical target volume to assure an adequate treatment and also showed that isocenter daily variation can cause an increase to the dose greater than the tolerance level to the critical organs.
337

Dosimetria Fricke Xilenol Gel na região de não-equilíbrio para radioterapia com feixes de fótons e elétrons / Fricke Xylenol Gel dosimetry in no-equilibrium for photons and electron beams radiotherapy

Moreira, Marcos Vasques 11 October 2012 (has links)
Quando se utiliza feixes de radiação ionizante de fótons e elétrons com altas energias, a região mais perto da superfície do paciente, região de não-equilíbrio, pode ter o comportamento das doses absorvidas comprometido devido a vários fatores como a presença de materiais auxiliares na radioterapia, exemplo o \"bolus\" (para superficializar a dose absorvida) e materiais imobilizadores como a máscara termoplástica. Dependendo da significância da incerteza no valor da dose absorvida, medidas devem ser tomadas para que esta seja mais próxima possível daquela prescrita. O objetivo desse trabalho é o de avaliar a capacidade do FXG para medidas de dose absorvida na região de não-equilíbrio e o comportamento dessas. Os objetivos específicos foram: (1) o de avaliar e comparar os (µ/?) experimentais e simulados (X-COM e GEANT-4) para diversos materiais, incluindo o FXG, (2) avaliar a influência da máscara termoplástica na dose absorvida prescrita e (3) determinar o ponto de equilíbrio eletrônico, R100, em função das energias dos feixes de fótons e elétrons para diversos materiais. Dos resultados obtidos tem-se que o (µ/?) relativo ao FXG é próximo daquele do tecido mole (TM), o material da máscara influencia a distribuição da dose absorvida na região de não-equilíbrio e os valores obtidos experimentalmente e por simulação MathLab® e PENELOPE® , indicam equivalência entre os materiais da câmara de ionização (CI) e Água, diferentes da equivalência do FXG eTM. Esse último resultado corrobora aquele obtido no experimento para determinação do (µ/?) , levando a concluir a adequabilidade do FXG para medidas na região de não-equilíbrio. / When one uses high energies photons and electrons ionizing radiations beam, the region closer to the surface of the patient, non-equilibrium region, can obtain the absorbed dose behavior compromised due to several factors such as the presence of auxiliary materials in radiotherapy, like the \"bolus\" (used to superficialize the absorbed dose) and immobilizing material as the thermoplastic mask. Depending on the significance of the uncertainty in the dose absorbed value, measurements must be taken in order the measured value be as close as possible to that prescribed. The aim of this paper is to evaluate the ability of FXG for the measurements of the absorbed dose in the region of non-equilibrium and their behavior. The specific object ives are: (1) to evaluate and compare the µ/? experimental and simulated (X-COM and GEANT-4) for various materials, including the FXG; (2) to evaluate the influence of the therm oplastic mask in the prescribed absorbed dose, and (3) to determine the equilibrium electronic point, R100, depending on the photon and electron beam energies for various materials. The results present that the FXG µ/? is close to that of the soft tissue (TM); the mask material influences the absorbed dose distribution in the non-equilibrium region, and the values obtained experimentally and also through MatLab® and Penelope® simulation indicate equivalence between the materials of ionization chamber (IC) a nd water, different from the equivalence between the FXG and TM. This last result corroborates the obtained one in the experiment for the µ/? determination, suggesting the adequacy of FXG for measurements in the non-equilibrium region.
338

Studio Doppler delle vene polmonari in cani affetti da malattia degenerativa valvolare cronica

Sanacore, Antonina <1982> 12 April 2010 (has links)
No description available.
339

L'ecografia ad elevata frequenza di emissione nell'esame della parete gasrica ed intestinale dei piccoli animali

Cepparulo, Alessandra <1977> 12 April 2010 (has links)
No description available.
340

Estudo da degradação causada pela radiação gama em polímeros utilizados em serviços de radioterapia

Ramos Neto, Antonio 28 November 2013 (has links)
Em serviços de radioterapia são utilizados acessórios confeccionados com diversos tipos de polímeros para auxiliar no posicionamento dos pacientes durante o tratamento e na execução das rotinas de trabalho. A radiação gama pode causar nos polímeros degradação de sua estrutura molecular que além de reduzir sua eficiência na assepsia e seu tempo de vida útil, pode também eliminar compostos orgânicos nocivos ao ambiente de trabalho. Neste trabalho é apresentado o estudo da degradação causada pela exposição à radiação gama em polímeros utilizados em serviços de radioterapia. Amostras de policarbonato (PC), polipropileno (PP), polimetilmetacrilato (PMMA) e compósito de poliuretana derivada de óleo de mamona com juta (PU-Juta), foram expostas a doses de radiação gama de 5 kGy (dose de algumas semanas de rotinas de radioterapia) a 25 kGy (dose de esterilização), sendo analisadas por espectrometria de absorção na região do infravermelho, indentação instrumentada, ângulo de contato e análise termogravimétrica. O PU-Juta mostrou-se o mais adequando para utilização, pois apresenta fragilização no material somente com doses acima de 20 kGy, por não perder sua característica hidrofílica permitindo assepsia de forma eficiente e por não possuir compostos orgânicos voláteis nocivos em sua composição. O PC apresentou indícios de fragilização a partir de 5 kGy, reduzindo drasticamente o tempo de vida útil e sendo o menos indicado em serviços onde haja exposição à radiação ionizante. / Radiotherapy Services uses many different types of polymeric accessories to assist in the positioning of patients during treatment and work routines. Gamma radiation can cause material degradation and allow that harmful compounds are released into the air. Also can harm the efficiency of sterilization and reduce the accessories useful life. This paper presents the study of the degradation caused by exposure to gamma radiation in polymers used in radiotherapy services. Samples of polycarbonate (PC), polypropylene (PP), polymethylmethacrylate (PMMA) and a composite of polyurethane derived from castor oil with Jute (PU-Jute) were exposed to gamma radiation doses of 5 kGy (few weeks of routines radiotherapy) to 25 kGy (sterilization dose) and analyzed by infrared spectroscopy, instrumented indentation, contact angle and thermal analysis. The PU-Jute samples proved to be the most fitting for use in places with radiation exposure. The material embrittlement was detected above 20 kGy doses. Also does not change their hydrophilic characteristic allowing aseptic procedures efficiently and has no harmful volatile compounds in the composition. The PC samples showed signs of embrittlement with 5 kGy reducing drastically their lifetime. Therefore is not suited for radiotherapy services.

Page generated in 0.0677 seconds