• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 14
  • 14
  • 11
  • 9
  • 6
  • 6
  • 5
  • 5
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Adaptation of the electroslag welding process to joining of railroad rail /

Turpin, Robert B. January 1983 (has links)
Thesis (M.S.)--Oregon Graduate Institute of Science and Technology, 1983.
2

Development and evaluation of glass fiber reinforced composite/wood railroad crossties

Laosiriphong, Krit. January 2000 (has links)
Thesis (M.S.)--West Virginia University, 2000. / Title from document title page. Document formatted into pages; contains vii, 125 p. : ill. (some col.). Includes abstract. Includes bibliographical references (p. 90-91).
3

Determining the transfer length in prestressed concrete railroad ties produced in the United States

Murphy, Robert Lawrence January 1900 (has links)
Master of Science / Department of Civil Engineering / Robert J. Peterman / This thesis presents results from transfer length measurements on prestressed concrete railroad ties. Results are shown from the four main producers of concrete ties in the United States. Six prestressed concrete tie plants were visited by the research team to measure transfer length on ties with various mix designs and prestressing reinforcement. After all plants had been visited, a total of nine concrete-mix designs and 10 reinforcement variations were tested. Overall, 220 transfer length measurements were conducted on prestressed concrete railroad ties during the duration of this research project. This was the first coordinated effort to measure transfer lengths in concrete railroad ties ever conducted in the industry. Concrete strains were monitored using the standard Whittemore gage, as well as a non-contact procedure called laser-speckle imaging (LSI). This method to measure transfer lengths has been developed at Kansas State University (KSU). Ties measured using the Whittemore gage were sent back to the civil engineering structural laboratory at KSU so the long-term transfer lengths could be monitored. After a certain period of time, the ties were load-tested according to the American Railway Engineering and Maintenance-of-Way Association (AREMA) loading specifications of the rail-seat positive moment test.
4

Precast prestressed ties on bridge girders : analytical and experimental load distribution studies

Igwemezie, Jude O. January 1983 (has links)
No description available.
5

Dynamic response and impact effects in precast, prestressed concrete bridge ties

Igwemezie, Jude O. January 1987 (has links)
No description available.
6

Precast prestressed ties on bridge girders : experimental response and design review

Igwe, Obi R. January 1983 (has links)
No description available.
7

Dynamic response and impact effects in precast, prestressed concrete bridge ties

Igwemezie, Jude O. January 1987 (has links)
No description available.
8

Precast prestressed ties on bridge girders : analytical and experimental load distribution studies

Igwemezie, Jude O. January 1983 (has links)
No description available.
9

Precast prestressed ties on bridge girders : experimental response and design review

Igwe, Obi R. January 1983 (has links)
No description available.
10

Un-tensioned pullout tests to predict the bond quality of different prestressing reinforcements used in concrete railroad ties

Arnold, Matthew Lukas January 1900 (has links)
Master of Science / Department of Civil Engineering / Robert J. Peterman / An experimental testing program was conducted at Kansas State University (KSU) to test the bond characteristics of various 5.32-mm-diameter steel wires and smaller diameter (less than 0.5 in.) strands used in prestressed concrete railroad ties. A total of 13 wires and six strands produced by seven different steel manufacturers were used during this testing. Since no wire bond pullout test currently exists, one was developed and its validity tested. This un-tensioned pullout test could serve as a quality control test similar to the standard test for strand bond (ASTM A1081) that has been developed for pretensioned strands. This strand test is currently not verified for strands less than 0.5-in. in diameter, so the procedure was also scrutinized using strands common in the concrete railroad tie industry. Some of the wires and strands contained surface indentations. It is generally accepted that indentations in the reinforcements improve the bond between the steel and concrete. To further complicate the issue, reinforcements with different surface conditions (rust, oils, lubricants) are allowed to be used in the concrete ties which further affects the bond quality of the reinforcements. However, no standardized indentation patterns (shape, size, depth of indent, etc.) or surface conditions (degree of rusting, amount of surface lubricants, etc.) are utilized by all wire and strand manufacturers. Thus, the corresponding bond behavior of these different reinforcements when placed in various concrete mixtures, in terms of average transfer lengths and typical variations, is essentially unknown. The purpose of this testing program was to develop (in the case of wires) or verify/develop (in the case of strands) a pullout testing procedure predictive of the reinforcement’s bond performance in a prestressed application. The test should be relatively inexpensive, demonstrably repeatable, and easily reproducible. Results from the un-tensioned pullout tests were compared to transfer length measurements from accompanying pretensioned concrete prisms in the lab. Additionally, pullout tests and transfer length measurements were obtained at an actual concrete railroad tie manufacturing plant. The obtained data was compared to the lab data and analyzed to further understand the relationship between un-tensioned pullout tests and pretensioned concrete members.

Page generated in 0.0465 seconds