• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 51
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 52
  • 52
  • 20
  • 20
  • 18
  • 17
  • 13
  • 10
  • 9
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação da confiabilidade e modo de falha de coroas cerâmicas parafusadas a implantes osseointegráveis de diferentes conexões

Delben, Juliana Aparecida [UNESP] 25 October 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-10-25Bitstream added on 2014-06-13T20:06:14Z : No. of bitstreams: 1 delben_ja_dr_araca.pdf: 2204033 bytes, checksum: 1d373c26a850bd8e588c8abb0d735054 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Introdução: A performance de restaurações cerâmicas parafusadas a implantes com diferentes conexões diante de fadiga é um fator importante para o sucesso do tratamento. Proposição: O objetivo do estudo foi avaliar a confiabilidade e o modo de falha de coroas cerâmicas obtidas com pilares de zircônia parafusadas a implantes osseointegráveis de diferentes conexões. Material e método: Foram formados 3 grupos de acordo com as diferentes conexões pilar-implante: Grupo EH - hexágono externo, Grupo IH - hexágono interno e Grupo MT - Cone Morse. As coroas foram obtidas através da aplicação de cerâmica de revestimento sobre pilar de zircônia utilizando a técnica de aplicação em camadas e parafusadas aos implantes com parafusos de retenção específicos para cada sistema. Os espécimes foram submetidos ao teste de fadiga acelerado step-stress de acordo com os perfis leve (n=9), moderado (n=6) e agressivo (n=3) determinados após teste de resistência à fratura (n=4) em máquina de ensaio universal. Os dados foram inicialmente avaliados pela análise de use level probability Weibull. Os valores e intervalos de confiabilidade foram obtidos através de standard probability calculation. Considerando os valores de carga para a falha dos espécimes, foi calculada a distribuição de Weibull. Análise fractográfica foi conduzida através de estereomicroscopia e microscopia eletrônica de varredura. Resultado: O valor de β de todos os grupos (EH-β= 0,6307; IH-β=0,9730; MT-β=0,1942) sugere que as falhas foram mais associadas ao nível de carga do que ao dano acumulado. Os valores de confiabilidade para uma missão de 50.000 ciclos e carga de 400 N foram de 97% para o grupo EH, 46% para o grupo IH e 0,5% para o grupo MT com... / Introduction: The performance of screw-retained all-ceramic crowns attached to implants with different connections under fatigue is a relevant factor for treatment success. Purpose: The aim of this study was to evaluate the reliability and failure mode of screw-retained all-ceramic crowns fabricated with zirconia abutments attached to osseointegrated implants with different connections. Material and method: Three groups were designed according to the implant-abutment connection: Group EH - external hexagon, Group IH - internal hexagon and Group MT - Morse taper. Layering technique was used for veneering of zirconia abutments. The crowns were attached to the implants with the retention screws of each system. Step-stress accelerated fatigue test was conducted according to mild (n=9), moderate (n=6) and aggressive (n=3) profiles determined after single-load-to-fracture test (n=4) in a universal testing machine. Data was previously analyzed by use level probability Weibull. Standard probability calculation was used to determine the reliability and confidence bounds. Weibull distribution was calculated based on the load to failure. Failure modes were described under light polarized microscopy and scanning electron microscopy. Result: β of all groups (EH-β= 0.6307; IH-β=0.9730; MT-β=0.1942) suggested that failure was associated to load instead of cumulative damage. Significant difference was observed between the groups for the calculated reliability in a mission of 50,000 cycles at 400 N (97% for group EH, 46% for group IH... (Complete abstract click electronic access below)
22

Novos parâmetros para o clareamento dental: avaliação da eficácia, citotoxicidade e efeitos moleculares

Soares, Diana Gabriela de Sousa [UNESP] 28 March 2014 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:30Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-28Bitstream added on 2015-01-26T13:30:19Z : No. of bitstreams: 1 000806001_20170328.pdf: 531116 bytes, checksum: 4bcef8dc36e6fadb7f840876180a7545 (MD5) Bitstreams deleted on 2017-03-31T12:19:25Z: 000806001_20170328.pdf,. Added 1 bitstream(s) on 2017-03-31T12:20:23Z : No. of bitstreams: 1 000806001.pdf: 3239201 bytes, checksum: 56301903e59b57f9f74a836016abf9ac (MD5) / Nesta pesquisa, foram analisadas a eficácia clareadora, citotoxicidade e características fenotípicas de células pulpares expostas a protocolos de clareamento de consultório experimentais. No primeiro estudo, discos de esmalte/dentina foram submetidos a 6 sessões clareadoras, caracterizadas por 1 ou 3 aplicações de peróxido de hidrogênio (H2O2) a 35% ou 17,5%, por 5 ou 15 min, ou de peróxido de carbamida (PC) a 37%, por 10 ou 20 min. A alteração de cor (E) e quantificação da difusão de H2O2 (violeta leuco-cristal/peroxidase) foram avaliadas. Todos os protocolos testados promoveram alteração significativa de cor associados a redução na difusão de H2O2; no entanto, o gel com PC apresentou os piores resultados (Traço de Pilai; Bonferroni/p<0,05). Apenas os protocolos 35% H2O2/ 1x 15 e 3x 5 min, 17,5% H2O2/ 3x 15 min e 37% PC/ 3x 20 min apresentaram valores de E similares ao protocolo tradicional (35%/ 3x 15 min) em até 6 sessões de clareamento (ANOVA; SNK e Tamhane/p>0.05). No segundo estudo, foi avaliada a citotoxicidade trans-amelodentinária causada pela aplicação de protocolos experimentais usando 35% H2O2/ 1x 15 e 1x 5 min e 17,5% H2O2/ 3x 15, 1x 15 e 1x 5 min. O protocolo 35% H2O2/ 3x 15 min foi empregado como controle positivo. Os discos de esmalte/dentina foram adaptados em dispositivos trans-well, os quais foram posicionados sobre células odontoblastóides (MDPC-23) e cultura primária de células pulpares humanas (HDPCs) previamente semeadas. A viabilidade (MTT) e morfologia celular (MEV) foram avaliadas imediatamente e 72 h pós-clareamento, bem como o estresse oxidativo e lesão à membrana celular (microscopia de fluorescência). Todos os protocolos experimentais avaliados reduziram significativamente o dano celular quando comparados ao controle positivo (Kruskal-Wallis; Mann-Whitney/p<0,05). Esta redução foi tempo/concentração dependente. As células expostas aos protocolos com o gel contendo 17,5% de... / In this study, the bleaching effectiveness, cytotoxicity and phenotypic characteristic of dental pulp cells exposed to experimental in-office bleaching protocols were analyzed. In the first study, enamel/dentin discs were subjected to 6 bleaching sessions, composed by 1 or 3 applications of a 35%- or 17.5%-H2O2 (hydrogen peroxide) gel, during 5 or 15 minutes, or by a 37%-CP (carbamide peroxide) gel, applied for 10 or 20 minutes. Color change (E) and H2O2 diffusion (leucocrystal violet/ peroxidase) were analyzed. All the tested protocols promoted significant color alteration and reduction of H2O2 diffusion; however, the CP gel presented the worst results (Pillai’s trace/ Bonferroni test; p<0.05). Only the protocols 35%-H2O2/ 1x 15, 35%-H2O2/ 3x 5 min, 17.5%-H2O2/ 3x 15 min and 37%-CP 3x 20 min presented similar E values than traditional protocol (35%-H2O2/ 3x 15 min) up to 6 sessions (ANOVA; SNK and Tamhane tests/p>0.05). In the second study, the trans-enamel and trans-dentinal cytotoxicity on dental pulp cells of selected experimental bleaching protocols (35%-H2O2/ 1x 15 and 1x 5 min; 17.5%-H2O2/ 3x 15, 1x 15 and 1x 5 min) were tested. The protocol 35%-H2O2/ 3x 15 min was considered as the positive control group. The enamel/dentin discs were adapted to trans-wells devices, which were positioned over odontoblast-like cells (MDPC-23) and primary culture of human dental pulp cells (HDPCs) previously seeded on culture plates. The cell viability (MTT) and morphology (SEM) were evaluated immediately and 72 h post-bleaching, as well as oxidative stress and cell membrane damage (fluorescence microscopy). The experimental protocols promoted significant minimization of cell damage, for all evaluated parameters, when compared to positive control, in a time/concentration fashion (Kruskal-Wallis; Mann-Whitney/ p<0.05). Cells exposed to protocols with the 17.5%-H2O2 gel presented cell recovery capability in around 50% three days after bleaching...
23

Análise de propriedades mecânicas e microscópicas de um gesso tipo IV após incorporação de derivados da clorexidina /

Lucas, Matheus Guilherme. January 2009 (has links)
Orientador: João Neudenir Arioli Filho / Banca: Sérgio Russi / Banca: José Cláudio Martins Segalla / Banca: Raphael de Freitas Souza / Banca: Wirley Gonçalves Assunção / Resumo: Neste trabalho foram analisadas as alterações nas propriedades físicas e mecânicas de um gesso odontológico do tipo IV após a incorporação de dois agentes desinfetantes (Digluconato e Cloridrato de clorexidina). Foram realizados testes mecânicos para a análise do tempo de presa, reprodução de detalhes, expansão de presa e resistência à compressão, já as alterações físicas foram analisadas através de uma microscopia eletrônica de varredura (MEV) nos aumentos de 375, 750, 1500 e 3000x. Os resultados demonstraram que somente houve alterações significantes no tempo de presa com a incorporação de Digluconato de Clorexidina 2,0% sem diluição e a resistência a compressão que demonstrou valores significantemente inferiores em todas as incorporações, porém todas as alterações dentro do limite estabelecido pela normatização para gessos odontológicos. Pela análise da Microscopia Eletrônica de Varredura, pode-se observar que os cristais obtiveram um aumento pela associação com os agentes derivados da clorexidina diminuindo os microporos existentes. Com isso verificamos que os derivados da clorexidina podem ser uma alternativa para a obtenção de modelos biologicamente seguros. / Abstract: The purpose of this study was to evaluate the alterations in physical and mechanical properties of a gypsum tipe IV after the incorporation of two disinfectant agents (Chlorhexidine hydrochlooride and Chlorhexidine gluconate). The mechanical tests are made for setting time, reproduction details, setting expansion and compressive tensile, and the physical properties was examinated in a scanning electron microscope (SEM) and photomicrographed are made in 375, 750,1500, 3000x and compared vissually. The results demonstrated were only significant alterations in the setting time with the incorporation of Chlorhexidine gluconate without dilution and the compression resistance that demonstrated under values in all of the incorporations, however all the alterations meet inside of the established limit for I.S.O values. In the analysis of the physical properties, the crystals obtained an increase for the association with the derived agent's clorhexidine. In conclusion, the incorporation clorhexidine agents can be a alternative to obtained biological models in dentistry. / Doutor
24

Novos parâmetros para o clareamento dental: avaliação da eficácia, citotoxicidade e efeitos moleculares /

Soares, Diana Gabriela de Sousa. January 2014 (has links)
Orientador: Carlos Alberto de Souza Costa / Banca: Ana Claudia Pavarina / Banca: Renata Garcia Fonseca / Banca: André Luis Fraga Briso / Banca: Adriano Fonseca de Lima / Resumo: Nesta pesquisa, foram analisadas a eficácia clareadora, citotoxicidade e características fenotípicas de células pulpares expostas a protocolos de clareamento de consultório experimentais. No primeiro estudo, discos de esmalte/dentina foram submetidos a 6 sessões clareadoras, caracterizadas por 1 ou 3 aplicações de peróxido de hidrogênio (H2O2) a 35% ou 17,5%, por 5 ou 15 min, ou de peróxido de carbamida (PC) a 37%, por 10 ou 20 min. A alteração de cor (E) e quantificação da difusão de H2O2 (violeta leuco-cristal/peroxidase) foram avaliadas. Todos os protocolos testados promoveram alteração significativa de cor associados a redução na difusão de H2O2; no entanto, o gel com PC apresentou os piores resultados (Traço de Pilai; Bonferroni/p<0,05). Apenas os protocolos 35% H2O2/ 1x 15 e 3x 5 min, 17,5% H2O2/ 3x 15 min e 37% PC/ 3x 20 min apresentaram valores de E similares ao protocolo tradicional (35%/ 3x 15 min) em até 6 sessões de clareamento (ANOVA; SNK e Tamhane/p>0.05). No segundo estudo, foi avaliada a citotoxicidade trans-amelodentinária causada pela aplicação de protocolos experimentais usando 35% H2O2/ 1x 15 e 1x 5 min e 17,5% H2O2/ 3x 15, 1x 15 e 1x 5 min. O protocolo 35% H2O2/ 3x 15 min foi empregado como controle positivo. Os discos de esmalte/dentina foram adaptados em dispositivos trans-well, os quais foram posicionados sobre células odontoblastóides (MDPC-23) e cultura primária de células pulpares humanas (HDPCs) previamente semeadas. A viabilidade (MTT) e morfologia celular (MEV) foram avaliadas imediatamente e 72 h pós-clareamento, bem como o estresse oxidativo e lesão à membrana celular (microscopia de fluorescência). Todos os protocolos experimentais avaliados reduziram significativamente o dano celular quando comparados ao controle positivo (Kruskal-Wallis; Mann-Whitney/p<0,05). Esta redução foi tempo/concentração dependente. As células expostas aos protocolos com o gel contendo 17,5% de... / Abstract: In this study, the bleaching effectiveness, cytotoxicity and phenotypic characteristic of dental pulp cells exposed to experimental in-office bleaching protocols were analyzed. In the first study, enamel/dentin discs were subjected to 6 bleaching sessions, composed by 1 or 3 applications of a 35%- or 17.5%-H2O2 (hydrogen peroxide) gel, during 5 or 15 minutes, or by a 37%-CP (carbamide peroxide) gel, applied for 10 or 20 minutes. Color change (E) and H2O2 diffusion (leucocrystal violet/ peroxidase) were analyzed. All the tested protocols promoted significant color alteration and reduction of H2O2 diffusion; however, the CP gel presented the worst results (Pillai's trace/ Bonferroni test; p<0.05). Only the protocols 35%-H2O2/ 1x 15, 35%-H2O2/ 3x 5 min, 17.5%-H2O2/ 3x 15 min and 37%-CP 3x 20 min presented similar E values than traditional protocol (35%-H2O2/ 3x 15 min) up to 6 sessions (ANOVA; SNK and Tamhane tests/p>0.05). In the second study, the trans-enamel and trans-dentinal cytotoxicity on dental pulp cells of selected experimental bleaching protocols (35%-H2O2/ 1x 15 and 1x 5 min; 17.5%-H2O2/ 3x 15, 1x 15 and 1x 5 min) were tested. The protocol 35%-H2O2/ 3x 15 min was considered as the positive control group. The enamel/dentin discs were adapted to trans-wells devices, which were positioned over odontoblast-like cells (MDPC-23) and primary culture of human dental pulp cells (HDPCs) previously seeded on culture plates. The cell viability (MTT) and morphology (SEM) were evaluated immediately and 72 h post-bleaching, as well as oxidative stress and cell membrane damage (fluorescence microscopy). The experimental protocols promoted significant minimization of cell damage, for all evaluated parameters, when compared to positive control, in a time/concentration fashion (Kruskal-Wallis; Mann-Whitney/ p<0.05). Cells exposed to protocols with the 17.5%-H2O2 gel presented cell recovery capability in around 50% three days after bleaching... / Doutor
25

Impacto da reabilitação com implantes e próteses dentárias em sujeitos com fissuras labiopalatais : uma revisão sistemática da literatura

Piffer, Caroline Scheeren January 2012 (has links)
Submitted by Ginamara Lima (ginaj@pucrs.br) on 2012-05-04T12:58:32Z No. of bitstreams: 1 438039.pdf: 1048914 bytes, checksum: 5fac15d84ef082aeae34b152a25d77a4 (MD5) / Made available in DSpace on 2012-05-04T12:58:32Z (GMT). No. of bitstreams: 1 438039.pdf: 1048914 bytes, checksum: 5fac15d84ef082aeae34b152a25d77a4 (MD5) / Fissuras labiopalatais representam a segunda deformidade congênita mais frequente, geralmente associada a deformidades estéticas, anormalidades dentais, problemas com fala, deglutição e crescimento. A maioria dos estudos que avaliam o sucesso de próteses e implantes dentários em pacientes fissurados não foi realizada com uma metodologia criteriosa e sistemática, ou apresentam um número pequeno de pacientes. O objetivo desta revisão sistemática foi avaliar a taxa de sucesso/sobrevida de próteses e implantes em pacientes fissurados e sua satisfação quanto à estética, mastigação e fonação. Uma busca eletrônica foi realizada em nove bases de dados e complementada por uma busca manual em 10 periódicos da área, segundo critérios de elegibilidade, palavras-chave e avaliação de qualidade. A busca eletrônica resultou em 323 estudos para análise de título e 180 para triagem por resumos. Após a busca manual e a triagem por texto completo, foram incluídos 27 estudos com delineamento de série de casos, estudo de coorte ou estudo transversal, sendo retrospectivos em sua maioria. Vinte e um artigos apresentaram próteses implanto-suportadas e sete estudos, próteses dento-suportadas. O tempo de acompanhamento variou de um mês a 25 anos. A taxa de sucesso dos implantes variou de 80 a 100%. Para as próteses, as taxas de sucesso foram: prótese com coroas telescópicas, 60%; prótese com sistema barra-clip, 78%; e próteses fixas, de 78% a 100%. A satisfação dos pacientes em relação à mastigação, fonação e estética variou de 70 a 85%. Conclui-se que existem evidências de que pacientes fissurados podem ser reabilitados com próteses dentárias com ou sem implantes, associados ou não a enxerto ósseo, desde que seja realizada uma avaliação criteriosa para o planejamento do caso. Os estudos incluídos foram muito heterogêneos quanto à metodologia e aos resultados; portanto, não foi possível realizar uma metanálise. / Cleft lip and palate represent the second most frequent congenital deformity, usually associated with aesthetic deformations, dental abnormalities, speech problems swallowing and growth. The majority of the studies that assessed the success of dental implants and prostheses in cleft patients was not held with a thorough and systematic methodology, or presents a small number of patients. The aim of this systematic review was to assess the success/survival rates of implants and prostheses in cleft patients and their satisfaction with aesthetics, phonetics and chewing. An electronic search was performed in nine databases by two independent and calibrated reviewers, followed by hand search within ten journals in the field using eligibility criteria, key-words and quality assessment. Electronic search yielded 323 and 180 studies for title and abstract screening, respectively. Following hand search and full-text screening, 27 studies were included with case series, cohort, cross-sectional and retrospective (majority) designs. Twenty-one studies provided implant-supported prostheses whereas seven provided tooth-supported prostheses for the patients. Follow-up period ranged from 1 month to 25 years. Success rate of the implants ranged from 80 to 100%. Regarding the prostheses, success rates were as follows: telescopic crowns (60%); bar-retained prostheses (78%); and fixed prostheses (78-100%). Patient's satisfaction with regards to chewing, phonetics and aesthetics ranged from 70 to 85%. It can be concluded that there are evidences that cleft patients can be successfully rehabilitated with dental prostheses with or without implant, combined or not with bone graft, as long as a meticulous treatment plan of the case is done. The included studies were all very heterogeneous with regards to the methodology and results; thus, a meta-analysis could not be performed.
26

Avaliação da resistência à fratura de dentes tratados endodonticamente com pinos pré-fabricados e resinas compostas variando a quantidade de remanescente dentário coronal / Fracture strength assessment of teeth endodontically treated, restored with prefabricated posts and compound resins, and varying amount of remaining coronal dental structure

Murilo Pereira de Melo 17 February 2003 (has links)
O objetivo desta pesquisa foi avaliar a influência do remanescente dentário coronal de dentes tratados endodonticamente, restaurados com pinos pré-fabricados e duas resinas como núcleos de preenchimento, uma de presa dual (Enforce Core) e outra fotopolimerizável (Z-250). Foram utilizados 40 caninos superiores humanos extraídos, divididos em quatro grupos de 10 espécimes: Grupo l – com remanescente dentário coronal de 3mm e restaurados com Enforce Core; Grupo ll – com remanescente dentário coronal de 3mm e restaurado com Z-250; Grupo III – sem remanescente dentário coronal e restaurado com Enforce Core; Grupo IV – sem remanescente dentário coronal e restaurado com Z-250. Após restaurados, os dentes foram levados a uma Máquina de Ensaio Universal e submetidos a uma força de compressão à 45º até que ocorresse fratura da restauração. A análise dos resultados (ANOVA, p>0,05) mostrou não haver diferença estatisticamente significativa entre os dentes com e sem remanescente dentário coronal. Com relação ao material utilizado para o preenchimento coronário, constatou-se diferença significativa, sendo que os valores mais elevados de resistência à fratura foram encontrados no grupo restaurado com a resina fotopolimerizável. / The aim of this study was to evaluate the remaining coronal dental structure influence of endodontically treated teeth, restored with prefabricated posts and two different types of resin filling cores, a dual cure resin (Enforce Core) and a photopolymerizing resin (Z-250). 40 extracted upper canine human teeth were used, divided into four groups of 10 specimens each: Group I – with coronal dental structure of 3mm restored with Enforce Core; Group II – with coronal dental structure of 3mm restored with Z-250; Group III – without any remaining coronal dental structure restored with Enforce Core; Group IV – without any remaining coronal dental structure restored with Z-250. After the complete restoration, the teeth were taken to a universal test machine, and then submitted to compression forces at 45º, until reaching the fracture of the restoration. The analysis of the results (ANOVA, p>0,05) showed no statistically significant difference between the teeth with or without coronal dental structure. In relation to the material used for the coronal filling, there has been a statistically significant difference. Higher fracture strength values were found in the group restored with photopolymerizing resin.
27

Dispositivo customizado produzido por manufatura aditiva para reabilitação oral em pacientes com regiões de atrofia óssea em áreas desdentadas extensas : Custom device produced by additive manufacturing for oral rehabilitation in patients with bone atrophy in regions of large edentulous areas / Custom device produced by additive manufacturing for oral rehabilitation in patients with bone atrophy in regions of large edentulous areas

Cardoso, Luiz de Camargo, 1958- 24 August 2018 (has links)
Orientador: Cecília Amélia de Carvalho Zavaglia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-24T20:04:45Z (GMT). No. of bitstreams: 1 Cardoso_LuizdeCamargo_M.pdf: 3937721 bytes, checksum: 35ed94c8bb9f043e9e463bd489f44ae5 (MD5) Previous issue date: 2014 / Resumo: A necessidade de reabilitação oral gera o desenvolvimento de inúmeras pesquisas com o intuito de inovações nesta área. O aumento da expectativa de vida, a busca pelo conforto e saúde são fatores primordiais para os aprimoramentos dos novos dispositivos de reabilitação oral. A atual pesquisa trata do desenvolvimento de um dispositivo de titânio intra-oral visando a reabilitação oral em pacientes com regiões ósseas atróficas. Para tanto foram realizados: a obtenção e tratamento da tomografia de um caso adequado; a criação do modelo virtual da mandíbula e do dispositivo; a confecção destes pelo processo de manufatura aditiva; ensaios de flexão e estudos in vitro do material Os valores de resistência à flexão do material foram superiores ao da região mandibular de um humano saudável. A análise do resultado do ensaio de citotoxicidade do titânio Ti-6Al-4V evidencia as características deste de ser um biomaterial. A análise dos resultados dos ensaios, mecânicos e do estudo in vitro, viabiliza a aplicação da liga de titânio Ti-6Al-4V no desenvolvimento deste dispositivo para reabilitação oral. O dispositivo se adapta perfeitamente ao protótipo da mandíbula, permitindo que posteriormente se torne justaposto ao osso e seja fixada a parte protética. Desse modo, o dispositivo desenvolvido possui características adequadas para se tornar uma opção factível para pacientes com regiões orais atróficas posteriores / Abstract: Research and new techniques are a real needed for a better treatment in oral rehabilitation. The increase of life expectancy leads to a search for comfort and health, Are fundamental for the development of devices that may provide an increase in life quality. The scope of this research is the development of a titanium device for intra-oral use that may allow oral rehabilitation in patients with atrophic and extended areas of bone lost. This research aims the device development which will give oral rehabilitation solution to cases where absences of vertical bone quantity does not allow the placement of traditional implants. In this study, were made the gathering and processing of the tomography of an appropriate case, the manufacture of the device by the virtual model and by additive manufacturing, the mechanical flexural test and cytotoxicity study where performed. The results presented show viability for the application that was studied. The flexural strength of the biomaterial was higher than the mandible region of a healthy human and the choice of the materials (titanium Ti - 6Al -4V) did not show any characteristic of cytotoxicity. The developed device is suitable as a prototype of the mandible, allowing subsequent juxtaposition to the bone and be is fixed in the prosthetic part. Thus, the developed device has suitable characteristics to become a feasible option for patients with atrophic oral posterior regions / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
28

Efeito da reabilitação oral com próteses totais convencionais sobre os estímulos perceptivos e a amplitude eletromiográfica do músculo orbicular da boca /

Caxias, Fernanda Pereira de. January 2017 (has links)
Orientador: Daniela Micheline Santos / Coorientadora: Karina Helga Turcio de Carvalho / Resumo: O envelhecimento acarreta uma série de modificações funcionais no corpo humano, incluindo o sistema estomatognático. Grande parcela de idosos sofre perdas dentárias ao longo da vida e necessita de tratamento protético para devolução da função mastigatória. Muitos optam pelo uso de próteses totais convencionais, que podem causar alguns desconfortos orais e modificações na amplitude eletromiográfica do músculo orbiculares da boca, cuja avaliação antes e após tratamento reabilitador justifica-se para o conhecimento da função muscular dos pacientes em situações orais diferentes. O objetivo deste estudo foi avaliar o efeito da reabilitação oral com novas próteses totais convencionais sobre os estímulos perceptivos e a amplitude eletromiográfica do músculo orbicular da boca. Foram selecionados pacientes da Clínica de Prótese Total da Faculdade de Odontologia de Araçatuba (UNESP) e da Clínica do Curso de Especialização em Prótese da Associação Paulista de Cirurgiões Dentistas (APCD) - Araçatuba, de acordo com critérios de inclusão pré-estabelecidos. Todos os pacientes selecionados assinaram um Termo de Consentimento Livre e Esclarecido. Esse estudo foi aprovado pelo Comitê de Ética em Pesquisa da Faculdade de Odontologia de Araçatuba -UNESP. Antes da instalação das novas próteses (T0), todos os pacientes, usando suas próteses velhas, responderam ao questionário de Percepção e foram submetidos a exames eletromiográficos de superfície do músculo orbicular da boca durante repouso, sucç... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Aging causes several modifications throughout the human body, including the stomatognathic system. A large portion of elderly suffers teeth loss along life and needs prosth etic treatment for devolution of the masticatory function. Many individuals opt for conventional complete dentures that might cause some oral discomfort and modification of orbicularis oris muscle's electromyographic a mplitude which evaluation before and a fter rehabilitation treatment is justified by the knowledge of muscle function of the individuals in different oral patterns. This study aimed to evaluate the effect of oral rehabilitation with conventional complete dentures on stimulus perception and the electr omyographic a mplitude of the orbicularis oris muscle. Patients from Complete Denture Clinic of Araçatuba Dental School and from the Clinic of Prosthesis Specialization Course of São Paulo Dental Surgeon Association - Araçatuba, wer e selected according to the prev iously established inclusion criteria. The selected patients signed a Consent Form. This study was approved by the Ethic Committee of Araçatuba Dental School. Before the new prostheses installation (T0), all the patients answered the Perception questionnaire and were submitted to surface electromyographic exams of orbicularis oris muscle during rest, suction of water with a straw and pronunciation of syllabus Bah, Mah Pah and the word Mississippi, wearing their old prosthesis. The procedures abo ve were repeated 30 (T1) and 100 days (T2) after the new prostheses installation. The data obtained from the Perception questionnaire were submitted to Q Cochran Test with 5% significance (p< 0.05 ). All data obtained from the electromyographic exams were su bmitted to Variance Analysis test (ANOVA) with repeated mea sures with two variance factors and p osteriorly, the data of exams...(Complete abstract electronic access below) / Mestre
29

Influência da ciclagem com cargas dinâmicas na microinfiltração de coroas metalocerâmicas cimentadas com três tipos de cimento

Rossetti, Paulo Henrique Orlato 29 April 2003 (has links)
O propósito deste estudo foi avaliar "in vitro" as mensurações e possíveis correlações entre discrepância de assentamento, abertura marginal e padrão de microinfiltração, em coroais metalocerâmicas cimentadas com três tipos de agentes cimentantes: fosfato, ionômero e cimento resinoso dual. Trinta dentes pré-molares humanos extraídos foram preparados para coroas metalocerâmicas e as fundições foram realizadas com liga de Ni-Cr. As amostras foram divididas em três grupos, de acordo com o agente cimentante e a cimentação foi realizada sob uma carga de 5Kg por 10 minutos e as amostras armazenadas em água por 24hs. A discrepância de assentamento foi registrada antes e após a cimentação em um microscópio óptico com precisão de 0,001micrometro. Metade dos espécimes dentro de cada grupo foi submetida ao teste de fadiga cíclica (50.000 ciclos, 2,5Hz). As coroas foram seccionadas longitudinalmente no sentido vestíbulo-lingual e na interface coroadente-cimento foi aplicado um corante (rodamina B) por 15 segundos. A penetração do corante foi quantificada ao longo da interface sob um microscópio óptico (80 vezes de aumento) e, posteriormente, as amostras foram preparadas para microscopia eletrônica de varredura a fim de quantificar a abertura marginal e a qualidade da interface. Os resultados de discrepância de assentamento foram maiores para o cimento fosfato de zinco, seguido do ionômero de vidro e resinoso, sem diferença estatística. Foram encontradas diferenças estatisticamente significantes entre a discrepância de assentamento e a abertura marginal para os três cimentos. Os resultados de infiltração foram maiores para o cimento fosfato de zinco, seguido do ionômero de vidro e resinoso, com diferenças estatisticamente significantes. A ciclagem mecânica aumentou a infiltração marginal para o cimento fosfato de zinco, com diferença estatisticamente significativa em relação ao cimento ionomérico e resinoso. A análise ao microscópio eletrônico de varredura detectou melhor qualidade de união na interface dente-cimento para o sistema resinoso, seguido pelo cimento ionomérico e resinoso. / The purpose of this study was to verify "in vitro" measures and possible correlations between seating discrepancy, marginal opening and microleakage pattern under total metallic crowns cemented with three types of luting agents: phosphate, glass-ionomer and resin dual cement. Thrirty extracted human premolars teeth were prepared for total metalloceramic crowns and castings obtained with a Ni-Cr alloy. Samples were ramdomly assigned for three groups in according to each luting agent: zinc phosphate (S.S.White), resin-modified glass-ionomer (Vitremer-3M) or a dual resin cement (Enforce-Dentsply). Cementation was done under a 49N load for 10 minutes and water stored for 24hs. Vertical discrepancy was registered before and after cementation in an optical microscopy with the accuracy of 0,001mm). Half of the specimens within each group was submitted to a cyclic loading test (50000 cycles, 2,5Hz). Crowns were longitudinally seccionated in a bucco- lingual plane at the tooth-cement-crown interface and dye solution (rodhamine B) was apllied to tooth-cement- interface for 15 seconds The linear stain penetration along tooth-cement was quantified. under a light microscope (80X magnification) and then samples were prepared for scanning electronic microscope in order to quantify marginal opening and the quality of interface. The results for seating discrepancy were higher for zinc phosphate, followed by glass-ionomer and resin cement, with no statistical difference. Statistically significant differences were found between seating discrepancy and marginal opening for the three cements. Microleakage results were higher for zinc phosphate, followed by glass-ionomer and resin cement, with statiscally significant differences. Fatigue loading rinsed marginal leakage for zinc pohsphate, with statiscally significant difference in respect to glassionomer and resin cement. Scanning electron microscope analysis showed better marginal quality at the tooth-cement-restoration interface for resinous cement,followed by glass-ionomer and zinc phosphate cement.
30

Avaliação do índice de sucesso de osseointegração em reabilitações tipo protocolo : análise retrospectiva em Cursos de Especialização em Implantodontia /

Monteiro, Ricardo Luís Prado. January 2018 (has links)
Orientador: Fernando Vagner Raldi / Banca: Rodrigo Dias Nascimento / Banca: Fábio da Silva Matuda / Resumo: O objetivo deste trabalho foi avaliar o índice de sucesso de Osseointegração por meio de uma revisão retrospectiva, dos prontuários de pacientes que receberam tratamento cirúrgico para a colocação de implantes em reabilitações totais do tipo protocolos maxilares e mandibulares, com carga tardia, realizados em cursos de pós-graduação em Implantodontia no Sindicato de Santo André - SP, ABO Regional de Barra Mansa - RJ e ABO Regional de Volta Redonda - RJ, no período de 2007 a 2013. Foram avaliados 2.208 implantes (Implacil®- São Paulo, Brasil), instalados em 398 pacientes (231 mulheres e 167 homens), com 1.323 implantes mandibulares e 885 implantes maxilares, com idade média de 59.2 anos, analisando: gênero, arcadas, tipo de implante, diâmetro e insucessos, no período de Osseointegração. Os resultados mostraram índice de insucesso em 19 mulheres (8%) e 11 homens (6,5%) com 36 implantes perdidos (1,7%), divididos em 18 perdas mandibulares (1,4%) e 18 perdas maxilares (2,1%). Com base na literatura, podemos concluir que o índice de sucesso de 98,3% obtido no estudo em cursos de especialização em implantodontia por nós ministrados foi satisfatório / Abstract : The objective of this study was to evaluate the success rate of Osseointegration by means of a retrospective review of the medical records of patients who received surgical treatment for the placement of implants in maxillary and mandibular late loading mandibular restorations performed in courses of post-graduation in Implant Dentistry at the São André Union - SP, ABO Regional of Barra Mansa - RJ and ABO Regional of Volta Redonda - RJ, from 2007 to 2013. Two hundred and twenty implants (Implacil®-São Paulo, Brazil) were evaluated, (231 women and 167 men), with 1,323 mandibular implants and 885 maxillary implants, with a mean age of 59.2 years, analyzing: gender, arches, type of implant, diameter and failures in the period of Osseointegration. The results showed failure rates in 19 women (8%) and 11 men (6.5%) with 36 implants lost (1.7%), divided into 18 mandibular losses (1.4%) and 18 maxillary losses (2,1%). Based on the literature, we can conclude that the success rate of 98.3% obtained in the study in specialization courses in implantology given by us was satisfactory / Mestre

Page generated in 0.0563 seconds