Spelling suggestions: "subject:"reatores químicos"" "subject:"featores químicos""
111 |
Modelagem e simulação dinâmica de reatores de leito fixoRodrigues, Caroline 25 February 2011 (has links)
Made available in DSpace on 2016-06-02T19:56:42Z (GMT). No. of bitstreams: 1
3506.pdf: 2271432 bytes, checksum: fc1d05123fb3be32395a9e84b2da5ad8 (MD5)
Previous issue date: 2011-02-25 / Universidade Federal de Sao Carlos / This work investigated numerical methods in the solution of mathematical models of fixed-bed reactors. For the reactors modeling and simulation, two numerical methods were used: sequencing method (SM) and finite volume method (FVM). There were also proposed two mathematical models: the pseudo-homogeneous model and the dimensionless one, which is based on the Peclet (Pe) and Biot (Bi) numbers. A horizontal-flow anaerobic immobilized sludge (HAIS) reactor developed in bench scale and after a scale-up, reducing the COD in the wastewater treatment was simulated by sequencing method, varying the numbers of mesh; a tubular fixed-bed reactor with biomass immobilized for the startup period of lactic acid fermentation, also simulated by sequencing method and compared with experimental data; and was also evaluated the precision of sequencing and finite volume methods over the reactor s profile, varying the Peclet e Biot numbers. The models development was based on studies about hydrodynamics and biochemistry kinetics. Both methods described satisfactorily the behavior of the reactors in the performed simulations, but in high values of Peclet, the finite volume method generated inadequacies such as oscillatory responses and over the limit. This paper is an elucidation to sequencing method, which besides its huge range and simplicity, still is not so studied neither known, because it s a recent method. / Este trabalho investigou metodos numericos na solucao de modelos matematicos para reatores de leito fixo. Para a modelagem e simulacao dos reatores, foram utilizados dois metodos numericos: metodo da sequencia (SM) e metodo dos volumes finitos (FVM). Foram propostos dois modelos matematicos: o pseudo-homogeneo e o adimensional, sendo este ultimo baseado nos numeros de Peclet (Pe) e Biot (Bi). Um reator anaerobio horizontal de leito fixo (RAHLF) desenvolvido inicialmente em escala de bancada e posterior aumento de escala na reducao da DQO de aguas residuarias foi simulado pelo metodo da sequencia, variando-se o numero de malhas; um reator tubular de leito fixo com biomassa anaerobia imobilizada no periodo da partida da fermentacao de acido latico, tambem simulado pelo metodo da sequencia e comparado com dados experimentais; e avaliou-se a precisao dos metodos da sequencia e dos volumes finitos sobre o perfil da concentracao de um reator, variando-se os valores de Peclet e Biot. O desenvolvimento dos modelos foi baseado em estudos sobre caracteristicas hidrodinamicas do sistema e de cinetica bioquimica. Ambos os metodos descreveram satisfatoriamente o comportamento dos reatores nas simulacoes realizadas, porem em valores elevados de Peclet, o metodo dos volumes finitos gerou inadequacoes como respostas oscilatorias e superiores ao limite. Este trabalho foi uma elucidacao ao metodo da sequencia, que apesar da sua grande abrangencia e simplicidade, por ser um metodo recente, ainda e pouco estudado e conhecido.
|
112 |
Influência da variação do TDH e da taxa recirculação no comportamento de reatores anaeróbio e aeróbio de leito fixo seguidos de filtro percolador na remoção de nitrogênio e fósforo / Influence of variation of HRT and the recirculation rate on the behavior of sequential anaerobic and aerobic fixed bed reactors and percolator filter in the removal of nitrogen and phosphorusGatti, Raphael Augusto Ferreira 13 February 2017 (has links)
CAPES / Com o aumento da população e o lançamento indevido de esgotos sanitários sem tratamento adequado, há aumento das cargas carbonáceas, nitrogenadas e fosforadas que pode acarretar na eutrofização de corpos hídricos. Há vários processos de tratamento, mas, a aplicação dos processos biológicos, na maioria dos casos, é a alternativa mais viável no Brasil. Porém, tem-se a necessidade de pós-tratamento, principalmente para remoção de nitrogênio e fósforo para alcançar os limites estabelecidos na legislação ambiental vigente. O objetivo deste trabalho foi avaliar o comportamento de um sistema composto por reator anaeróbio (20 L), seguido de reator aeróbio (19 L), preenchidos com anéis corrugados de Policloreto de Polivinila (PVC) como leito fixo, seguido de coluna de adsorção (16 L) preenchida com cerâmica vermelha. O sistema foi submetido à variação do tempo de detenção hidráulica (TDH) e da taxa de recirculação (R) e operado em série com escoamento ascendente e fluxo contínuo. Foram testadas as razões de recirculação de 150, 100 e 50% e os TDHs de 5, 7 e 9 h, com vazão de aeração constante de 10 L min-1. Na avaliação do sistema, foram determinados temperatura do líquido, pH, alcalinidade total e a bicarbonato, ácidos voláteis, oxigênio dissolvido (OD), demanda química de oxigênio (DQO), demanda bioquímica de oxigênio (DBO), nitrogênio total Kjeldahl (NTK), nitrogênio amoniacal, nitrito, nitrato e fósforo total. As eficiências de remoção alcançadas pelo sistema foram de - 98, 98 e 99% para DQO em amostras brutas, 96, 89 e 87% para NTK e 78, 82 e 77% para fósforo, quando operado com taxas de recirculação de 150, 100 e 50%, respectivamente. Em relação à variação do TDH em 9, 7 e 5 h, as eficiências de remoção obtidas foram de 86, 96 e 98% para DQO de amostras brutas, 90, 93 e 94% para NTK e 74, 89 e 95% para fósforo total, respectivamente. Com os resultados obtidos, foi possível concluir que a melhor condição operacional foi com razão de recirculação de 150% e TDH de 5 h. Com a análise estatística, por meio do delineamento composto central rotacional (DCCR) e da desejabilidade, pode-se obter a condição ótima de operação com TDH de 5 h e taxa de recirculação de 123%. Também foi possível validar os modelos estatísticos para nitrificação, desnitrificação, remoção de nitrogênio total e remoção de fósforo para as condições operacionais avaliadas. / With the increase of the population and the undue discharge of sanitary sewage without adequate treatment, there is an increase of the carbonaceous, nitrogenous and phosphorus loads which can lead to the eutrophication of water bodies. There are several treatment processes, but the application of biological processes, in most of cases, is the most viable alternative in Brazil. However, there is a need for post-treatment, mainly for the removal of nitrogen and phosphorus in order to achieve the standards established in the current environmental legislation. The objective of this work is to evaluate the behavior of a system composed by an anaerobic reactor (20 L), followed by an aerobic reactor (19 L), filled with corrugated rings of Polyvinyl chloride (PVC) as the fixed bed, followed by a trickling filter (16 L) filled with red clay. The system was subjected to the variation of the hydraulic retention time (HRT) and the recirculation rate (R), operated in series with upflow and continuous flow. Recirculation ratios of 150, 100 and 50% and HRT of 5, 7 and 9 h with constant aeration flow rate of 10 L min-1 were tested. For the evaluation of the system, were determined the liquid temperature, pH, total and bicarbonate alkalinity, volatile acids, dissolved oxygen (OD), chemical oxygen demand (COD), biochemical oxygen demand (BOD), total Kjeldahl nitrogen (TKN), ammoniacal nitrogen, nitrite, nitrate and total phosphorus. The removal efficiencies achieved by the system were - 98, 98 and 99% to the raw COD, 96, 89 and 87% to TKN and 78, 82 and 77% to phosphorus, when operated with recirculation rates of 150, 100 and 50%, respectively. Regarding the HRT variation in 5, 7 and 9 h, the removal efficiencies obtained were 86, 96 and 98% to the raw COD, 90, 93 and 94% to NTK and 74, 89 and 95 % to total phosphorus, respectively. With the results obtained, it was possible to conclude that the best operational condition was with recirculation ratio of 150% and HRT of 5 h. With the statistical analysis, by means of the central composite rotational design (CCRD) and the desirability, it was possible to obtain the optimal condition of operation with HRT of 5 h and recirculation rate of 123%. It was also possible to validate the statistical models for nitrification, denitrification, total nitrogen removal and phosphorus removal to the operational conditions evaluated.
|
113 |
Remoção de nitrogênio e fósforo do esgoto sanitário por reator anaeróbio-aeróbio de leito fixo (RAALF), com recirculação da fase líquida / Nitrogen removal and phosphorus from wastewater by anaerobic-aerobic fixed bed reactor (AAFBR) with recirculating the liquid phaseFreitas, Daiane Cristina de 27 July 2016 (has links)
A escolha de um sistema de tratamento de efluentes deve levar em conta aspectos técnicos e econômicos, dentre os quais a eficiência do processo. Assim, o objetivo desta pesquisa foi avaliar a remoção de nitrogênio e fósforo em um reator anaeróbio-aeróbio de leito fixo, operado em escala de bancada, com recirculação da fase líquida. O reator, com volume útil de 6,95 L, foi operado com meio suporte de espuma de poliuretano e mantido à temperatura ambiente, sendo o efluente tratado sintético, simulando o esgoto sanitário. Foram testadas diferentes razões de recirculação (0,5; 1,0 e 1,5) e diferentes TDH (4, 8, e 12) e, com vazão de ar constante de 10 L min-1. Com a variação destes fatores foi possível verificar a influência da razão de recirculação na remoção de nitrogênio e fósforo e a influência do TDH na remoção de nitrogênio e fósforo. Durante o período de operação foram analisados os parâmetros físico-químicos: temperatura, pH, alcalinidade a bicarbonato, ácidos voláteis, oxigênio dissolvido, demanda química de oxigênio, demanda bioquímica de oxigênio, sólidos totais, sólidos suspensos totais, nitrogênio total kjeldahl, nitrogênio amoniacal, nitrito, nitrato e fósforo. Também foram realizados ensaios hidrodinâmicos por meio de testes estímulo-resposta tipo pulso com o traçador eosina Y, para avaliar o comportamento hidrodinâmico e verificar a existência de anomalias. E por fim realizou-se a análise estatística para encontrar a condição ótima de operação e os modelos estatísticos para validação. Tanto para a variação de razão de recirculação quanto para a variação de TDH, a temperatura, oxigênio dissolvido e pH contribuíram para o desenvolvimento dos microrganismos. A alcalinidade a bicarbonato e ácidos voláteis indicaram estabilidade no interior do reator. A razão de recirculação 50% foi a condição de maior eficiência de remoção para sólidos totais (83%). A razão de recirculação 100% foi a de maior eficiência para NTK (97%) e Namon (99%). Para a razão de recirculação de 150% a maior eficiência de remoção foi para fósforo (33%). Avaliou-se também a influência da sobrecarga hidráulica no desempenho do reator quanto à remoção de nitrogênio e fósforo e foi possível perceber que o TDH de 12 h foi a condição que resultou em maiores eficiências de remoção. E em relação ao comportamento hidrodinâmico do reator, ele se assemelha a mistura completa, isso pode ser verificado por meio das curvas DTR e coeficientes de correlação. Quando variado o TDH observou-se a presença de zonas mortas (exceto para o TDH de 12 h), que indica ocorrência de caminhos preferenciais. No TDH de 12 h foi observado curto circuitos hidráulicos e eficiência hidráulica insatisfatória. Pela análise estatística no delineamento do composto central rotacional, foi possível encontrar por meio da desejabilidade a condição ótima de operação com TDH de 12 h e razão de recirculação de 122,36%. Ainda foi possível encontrar os modelos estatísticos para nitrificação, desnitrificação e nitrogênio total e valida-los para as condições operadas. / The choice of an effluent treatment system must take into account technical and economic aspects, among which the process efficiency. The objective of this research was to evaluate the removal of nitrogen and phosphorus in an anaerobic-aerobic fixed bed reactor, operated at bench scale, with recirculation of the liquid phase. The reactor, with a volume of 6.95 L, was operated with polyurethane foam support and maintained at room temperature with the synthetic effluent treated by simulating the sewage. Different recirculation ratios were tested (0.5, 1.0 and 1.5) and different HRT (4, 8, and 12) with constant air flow rate of 10 L min-1. With the variation of these factors was possible to verify the influence of the recirculation ratio on nitrogen removal and the influence of HRT in removing nitrogen. During the operation period, was analyzed the physical and chemical parameters: temperature, pH, bicarbonate alkalinity, volatile acids, dissolved oxygen, chemical oxygen demand, biochemical oxygen demand, total, total suspended solids solids, nitrogen total kjeldahl ammonia nitrogen , nitrite, nitrate and phosphorus. It was also developed hydrodynamic tests through stimulus-response pulse with eosin Y tracer to evaluate the hydrodynamic behavior and check for abnormalities. And finally, there was the statistical analysis to find the optimal operating condition and statistical models for validation. For any variation due to recirculation as variation of HRT, temperature, dissolved oxygen and pH contributed to the development of microorganisms. The bicarbonate alkalinity and volatile acids indicated stability within the reactor. The recirculation ratio 50% was highest efficiency condition for total solids removal (83%). Recirculation ratio 100% was the highest efficiency for TKN (97%) and Namon (99%). A recirculation ratio of 150% was a higher removal efficiency for phosphorus (33%). It was also evaluated the influence of hydraulic overload in the reactor performance as the removal of nitrogen and phosphorus and it was revealed that the HRT of 8 h was the condition which resulted in higher removal efficiencies. Regarding hydrodynamic behavior of the reactor, it resembles complete mixture, verified by DTR curves and correlation coefficients. When varied HRT can observe the presence of dead zones (except for HRT of 12 h), which indicates occurrence of preferential paths. In HRT of 12 h was observed hydraulic short circuits and poor hydraulic efficiency. For the statistical analysis in the design of the central composite, was found by the desirability optimum operation condition with HRT of 12 h and recirculation ratio of 122.36%. It was still possible to find statistical models for nitrification, denitrification and total nitrogen and validates them for the operated conditions.
|
114 |
Influência da variação do TDH e da taxa recirculação no comportamento de reatores anaeróbio e aeróbio de leito fixo seguidos de filtro percolador na remoção de nitrogênio e fósforo / Influence of variation of HRT and the recirculation rate on the behavior of sequential anaerobic and aerobic fixed bed reactors and percolator filter in the removal of nitrogen and phosphorusGatti, Raphael Augusto Ferreira 13 February 2017 (has links)
CAPES / Com o aumento da população e o lançamento indevido de esgotos sanitários sem tratamento adequado, há aumento das cargas carbonáceas, nitrogenadas e fosforadas que pode acarretar na eutrofização de corpos hídricos. Há vários processos de tratamento, mas, a aplicação dos processos biológicos, na maioria dos casos, é a alternativa mais viável no Brasil. Porém, tem-se a necessidade de pós-tratamento, principalmente para remoção de nitrogênio e fósforo para alcançar os limites estabelecidos na legislação ambiental vigente. O objetivo deste trabalho foi avaliar o comportamento de um sistema composto por reator anaeróbio (20 L), seguido de reator aeróbio (19 L), preenchidos com anéis corrugados de Policloreto de Polivinila (PVC) como leito fixo, seguido de coluna de adsorção (16 L) preenchida com cerâmica vermelha. O sistema foi submetido à variação do tempo de detenção hidráulica (TDH) e da taxa de recirculação (R) e operado em série com escoamento ascendente e fluxo contínuo. Foram testadas as razões de recirculação de 150, 100 e 50% e os TDHs de 5, 7 e 9 h, com vazão de aeração constante de 10 L min-1. Na avaliação do sistema, foram determinados temperatura do líquido, pH, alcalinidade total e a bicarbonato, ácidos voláteis, oxigênio dissolvido (OD), demanda química de oxigênio (DQO), demanda bioquímica de oxigênio (DBO), nitrogênio total Kjeldahl (NTK), nitrogênio amoniacal, nitrito, nitrato e fósforo total. As eficiências de remoção alcançadas pelo sistema foram de - 98, 98 e 99% para DQO em amostras brutas, 96, 89 e 87% para NTK e 78, 82 e 77% para fósforo, quando operado com taxas de recirculação de 150, 100 e 50%, respectivamente. Em relação à variação do TDH em 9, 7 e 5 h, as eficiências de remoção obtidas foram de 86, 96 e 98% para DQO de amostras brutas, 90, 93 e 94% para NTK e 74, 89 e 95% para fósforo total, respectivamente. Com os resultados obtidos, foi possível concluir que a melhor condição operacional foi com razão de recirculação de 150% e TDH de 5 h. Com a análise estatística, por meio do delineamento composto central rotacional (DCCR) e da desejabilidade, pode-se obter a condição ótima de operação com TDH de 5 h e taxa de recirculação de 123%. Também foi possível validar os modelos estatísticos para nitrificação, desnitrificação, remoção de nitrogênio total e remoção de fósforo para as condições operacionais avaliadas. / With the increase of the population and the undue discharge of sanitary sewage without adequate treatment, there is an increase of the carbonaceous, nitrogenous and phosphorus loads which can lead to the eutrophication of water bodies. There are several treatment processes, but the application of biological processes, in most of cases, is the most viable alternative in Brazil. However, there is a need for post-treatment, mainly for the removal of nitrogen and phosphorus in order to achieve the standards established in the current environmental legislation. The objective of this work is to evaluate the behavior of a system composed by an anaerobic reactor (20 L), followed by an aerobic reactor (19 L), filled with corrugated rings of Polyvinyl chloride (PVC) as the fixed bed, followed by a trickling filter (16 L) filled with red clay. The system was subjected to the variation of the hydraulic retention time (HRT) and the recirculation rate (R), operated in series with upflow and continuous flow. Recirculation ratios of 150, 100 and 50% and HRT of 5, 7 and 9 h with constant aeration flow rate of 10 L min-1 were tested. For the evaluation of the system, were determined the liquid temperature, pH, total and bicarbonate alkalinity, volatile acids, dissolved oxygen (OD), chemical oxygen demand (COD), biochemical oxygen demand (BOD), total Kjeldahl nitrogen (TKN), ammoniacal nitrogen, nitrite, nitrate and total phosphorus. The removal efficiencies achieved by the system were - 98, 98 and 99% to the raw COD, 96, 89 and 87% to TKN and 78, 82 and 77% to phosphorus, when operated with recirculation rates of 150, 100 and 50%, respectively. Regarding the HRT variation in 5, 7 and 9 h, the removal efficiencies obtained were 86, 96 and 98% to the raw COD, 90, 93 and 94% to NTK and 74, 89 and 95 % to total phosphorus, respectively. With the results obtained, it was possible to conclude that the best operational condition was with recirculation ratio of 150% and HRT of 5 h. With the statistical analysis, by means of the central composite rotational design (CCRD) and the desirability, it was possible to obtain the optimal condition of operation with HRT of 5 h and recirculation rate of 123%. It was also possible to validate the statistical models for nitrification, denitrification, total nitrogen removal and phosphorus removal to the operational conditions evaluated.
|
115 |
Eletroxidação de cloranfenicol e outros poluentes organicos utilizando reatores eletroquimicos, constituidos de anodos tipo DSA ou de diamante dopado com boro (DDB) / Electrooxidation of chloramphenicol and otherpollutants using electrochemical reactors composed with a DSA type anode or a boron-doped diamond anodeSpitzer, Marcos 30 September 2005 (has links)
Orientador: Rodnei Bertazzoli / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-05T06:46:31Z (GMT). No. of bitstreams: 1
Spitzer_Marcos_D.pdf: 1019872 bytes, checksum: 57974ac02038eb53169c99987a119811 (MD5)
Previous issue date: 2005 / Resumo: O método de oxidação eletroquímica foi aplicado a soluções aquosas contendo cloranfenicol (CAP) e outros compostos orgânicos. Para isso, utilizou-se um anodo de óxido condutor, comercial, tipo DSA®, de composição 70TiO2-30RuO2 e um anodo de diamante dopado com boro (DDB) tipo comercial. Cada anodo foi instalado em um reator tipo filtro-presa, em escala de bancada, para processamento de 2 a 3 L de solução em modo de batelo-reciclo. Inicialmente, nos reatores construídos foram realizados estudos voltamétricos, em modo hidrodinâmico. Sobre um catodo de aço inoxidável, antes da evolução de H2, observou-se a redução do grupo NO2 do CAP a HO-NH- a pH=5, e em potenciais anódicos, sobre o DSA®, observou-se o início reação de evolução de O2 a partir de 1 V vs. ECS e que a presença de CAP reduz as correntes de evolução de O2. Sobre o DDB, o CAP é oxidado a partir de 0,6 V resultado na passivação do anodo. A partir de 2,2 V observa-se o início da evolução de O2 sobre o DDB, resultando na eliminação do filme passivador. Em seguida, eletrólises exaustivas foram realizadas, em modo galvanostático, com ambos os anodos, dentro da região de evolução de O2. Cinéticas de pseudo-primeira ordem foram observadas dos decaimentos ds CAP sobre o DSA®, na faixa de 50 a 180 mA cm-2, e sobre o DDB, na faixa de 10 a 30 mA cm-2. Os decaimentos da demanda química de O2 (DQO) e do carbono orgânico total (COT) também apresentaram essa cinética quando as reações de oxidação sobre o DDB tornavam-se controladas pelos processos de transporte de massa. A partir de eletrólises de soluções de K2SO4 com o DDB observou-se a geração de H2O2. Os números adimensionais Sherwood (Se), Reynolds (Re) e Schmidt (Sc) foram determinados a partir de dados de transporte de massa obtidos a partir de cinéticas da degradação do CAP em função da vazão. No reator composto de DSA® observou-se um regime de fluxo laminar a baixo de Re = 2000 e um regime de fluxo turbulento acima desse valor, como esperado para um reator de placas paralelas. No reator de DDB, devido o aumento da área da secção transversal do compartimento entre eletrodos, há uma elevação de turbulência da face do anodo, impedindo a formação de um regime de fluxo laminar bem definido. Utilizando um efluente real contendo fenóis e derivados, foram aplicadas valores apropriados de densidade de corrente (Jap) para aumento dos valores de eficiência de corrente e diminuição dos índices de consumo energético. Aplicando-se um perfil exponencial de Jap (t) obteve-se um rendimento de corrente médio de 95 % e um consumo de 23,5 kWh por kg de O2. Com isso foi possível propor um método de operação de reatores de DDB para elevação dos índices de eficiência. De modo geral, os anodos de Ti/70TiO2-30RuO2 e de DDB ótimos desempenhos para a eletroxidação de cloranfenicol (CAP) e outros compostos orgânicos e para redução da DQO e do COT / Abstract: Electrochemical oxidation was used as a method for organic pollutant degradation in aqueous media. In the technique was used in solutions containing chloramphenicol (CAP) and phenolic compounds. A commercial DSA® type anode, of composition 70TiO2-30RuO2, and a boron-doped diamond anode (BDD) were used. Each anode was mounted in a filter-press type reactor connected to a recirculating flow system with 3 L of capacity. Initially, voltammetric studies were carried out with electrochemical reactors operating in hydrodynamic mode. On the DSA® type anode O2 evolution reaction was observed after 1 V vs. SCE and the current densities for O2 evolution decreased when chloramphenicol was present in solution. On stainless steel cathode, before H2 evolution, reduction of NO2 group to HO-NH- group was observed for CAP molecule, at pH = 5. On DDB, the anode was passived with an organic film at potentials from 0.6 V. Current responses on DDB anode were restored after anodic treatments within O2 evolution range of potentials. On BDD, O2 evolution took place after 2.2 V vs SCE. Galvanostatic experiments were carried out within the range of potentials for O2 evolution. Pseudo-first order kinetics were observed for CAP concentration decay on the DSA® anode, when current densities (Jap) were ranged from 50 to 180 mA cm-2, and from 10 to 30 mA cm-2 on DDB anode. Chemical oxygen demand (COD) and total organic carbon (TOC) showed linear concentration decays when the oxidation reactions were controlled by charge transfer process and it showed exponential decays when these reactions were controlled by mass transfer process. H2O2 production on DDB anode was investigated as function of Jap. Dimensionless numbers and their mass transfer figures of merit were studied from mass transport data of CAP decays as function of several flow rates. In the reactor composed by DSA® anode, a laminar flow was observed below Reynolds (Re) equal 2000 and a turbulent flow was observed above this value. In the BDD reactor, the transition between laminar and turbulent flow was not observed. Using a real effluent composed by phenols and derivates, appropriate values of Jap was applied on DDB reactor to increase the anodic efficiency and to reduce the energy consumption per kg of O2. Applying an exponential profile of Jap in galvanostatic experiments, an anodic efficiency of 95% was reached, corresponding to an energy consumption of 23,5 kWh per kg of O2. From these results an operation method of BDD reactors arose in order to increase the performance of this electrochemical device. Good performances were observed when DSA® and BDD anodes were used in electrochemical oxidation of chloramphenicol and other organic pollutants, especially in BDD case / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
|
Page generated in 0.0803 seconds