Previous issue date: 2017-03-22 / The hydrological model Soil and Water Assessment Tool (SWAT) is an important tool
in the management of water resources, and can contribute to the estimation of
streamflow to hydroelectric reservoirs. The objective of this study was to simulate the
flow in the drainage area of the Furnas reservoir, located in the Rio Grande basin (MG).
The series of meteorological and hydrological data included in the study corresponded
to the period from 01/01/1998 to 12/31/2013. In the development of the model the
following steps were adopted: (1) parameterization of the input data; (2) configuration
of the model; (3) warm up and simulation; (4) sensitivity analysis; (5) calibration,
validation and analysis of results. Calibration, validation and uncertainty analysis were
performed using the Sequential Uncertainty Fitting (SUFI-2) algorithm through the
Uncertainty Calibration Program (SWAT-CUP). The calibration and validation
adjustment was measured by applying the P-Factor (percentage of the measured data
bracketed by the 95PPU), the R-Factor (mean uncertainty band thickness) and the Nash
and Sutcliffe (NSE) objective function. The P-factor values corresponded to 0.94 and
0.69 for calibration and validation, respectively. The NSE values were 0.86 for the
calibration and 0.64 for the validation. The results obtained show a reasonable precision
in relation to the literature, being within acceptable intervals, characterizing the model
as adequate to estimate reservoir flows, considering the uncertainties of prediction. The
construction of models from the SWAT allows the definition of best practices of
management of water resources and of hydroelectric reservoirs. / O modelo hidrológico Soil and Water Assessment Tool (SWAT) é uma importante
ferramenta na gestão de recursos hídricos, podendo contribuir para estimativas de vazão
a reservatórios hidrelétricos. O objetivo deste estudo foi simular a vazão na área de
drenagem do reservatório da UHE Furnas, localizado na bacia do rio Grande (MG). A
série de dados meteorológicos e hidrológicos incluída no estudo correspondeu ao
período de 01/01/1998 à 31/12/2013. No desenvolvimento do modelo foram adotadas as
etapas: (1) parametrização dos dados de entrada; (2) configuração do modelo; (3)
aquecimento e simulação; (4) análise de sensibilidade; (5) calibração, validação e
análise dos resultados. A calibração, validação e análise de incertezas foram realizadas
utilizando o algoritmo Sequential Uncertainty Fitting (SUFI-2) através do Programa de
Incerteza de Calibração (SWAT-CUP). O ajuste da calibração e validação foi
mensurado aplicando o P-Fator (porcentagem de dados incluídos na faixa de incerteza
de 95%), o R-Fator (espessura média da faixa de incerteza) e a função objetivo Nash e
Sutcliffe (NSE). Os valores do P-Fator corresponderam a 0,94 e 0,69 para calibração e
validação, respectivamente. Os valores do NSE foram de 0,86 para a calibração e 0,64
para a validação. Os resultados encontrados apresentam precisão razoável em relação à
literatura, estando dentro de intervalos considerados aceitáveis, caracterizando o modelo
como adequado para simular vazões ao reservatório, se consideradas as incertezas de
predição. A construção de modelos a partir do SWAT permite a definição de melhores
práticas de gerenciamento de recursos hídricos e de reservatórios hidrelétricos.
|
2 |
Efeito da fragmentação e o isolamento da paisagem na riqueza e composição de espécies de lagartos no Reservatório de Tucuruí, ParáLIMA, Crisalda de Jesus dos Santos 29 August 2008 (has links)
Submitted by Irvana Coutinho (irvana@ufpa.br) on 2012-07-31T15:22:46Z
No. of bitstreams: 2
Dissertacao_EfeitoF ragmentacaoIsolamento.pdf: 6979661 bytes, checksum: adbdd9de72de13a09b1e47159d01c949 (MD5)
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2012-07-31T15:22:46Z (GMT). No. of bitstreams: 2
Dissertacao_EfeitoF ragmentacaoIsolamento.pdf: 6979661 bytes, checksum: adbdd9de72de13a09b1e47159d01c949 (MD5)
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Previous issue date: 2008 / MPEG - Museu Paraense Emílio Goeldi / Eletronorte - Centrais Elétricas do Norte do Brasil S/A / Sociedade Zeladora "Amigos" Museu Paraense Emílio Goeldi / MCT/Brasil - Ministério da Ciência e Tecnologia / Apesar de vários trabalhos publicados para a região tropical demonstrando o efeito da fragmentação florestal e o isolamento da paisagem na comunidade biótica, a maioria destes, foi realizada em regiões continentais. Os impactos da fragmentação e o isolamento da paisagem resultante da criação de reservatórios artificiais de usinas hidrelétricas ainda são pouco estudados na Amazônia. Este estudo foi realizado em fragmentos ('ilhas") remanescentes de floresta ombrófila, formadas pela construção da Hidrelétrica de Tucuruí, no estado do Pará com o objetivo de comparar as ilhas nas duas margens do reservatório em relação ao tamanho total, tamanho da área nuclear (core area) , forma geométrica (total de borda balanceado pela área da ilha) e grau de isolamento a fim demonstrar o papel das mesmas para a conservação da biota local e em escala local avaliar a riqueza, abundância e composição de espécies da comunidade de lagartos em 12 "ilhas" do reservatório em relação ao tamanho, grau de isolamento e posição das ilhas no reservatório. Para o estudo em escala da paisagem foram escolhidas 199 ilhas nas duas margens no limite da Área de Proteção Ambiental de Tucuruí usando imagem de satélite de 2005. O tamanho das ilhas analisadas varia de 3 a 1768 hectares , sendo que 40% delas com menos 10 hectares . As ilhas têm uma perda significativa, variando de 22% a 100%, de área total, em função do efeito de borda. Não houve diferença significativa no tamanho total, tamanho da área nuclear e total da borda I')as ilhas em relação á margem do reservatório. Contudo, as ilhas da margem esquerda têm maior grau de isolamento em relação das ilhas da margem direita. A maioria das ilhas analisadas no reservatório de Tucuruí tem tamanhos pequenos, alta perda de área total em função do efeito de borda, formato irregular o que aumenta o potencial do efeito de borda e alto grau de isolamento. Em escala local a comunidade de lagartos foi amostrada em cinco campanhas de campo realizadas entre janeiro e julho de 2005, através de transectos e armadilhas de queda. As áreas inventariadas foram selecionadas com base no tamanho, grau de isolamento e posição na margem do reservatório. Foram registrados 837 indivíduos de lagartos, distribuídos em 16 espécies. As espécies mais abundantes foram Gonatodes humeralis e Coleodactylus amazonicus (Gekkonidae). A amostragem realizada nas cinco campanhas foi suficiente para determinar a riqueza total das ilhas amostradas, correspondendo a 84% do número de espécies de acordo com o estimador Jacknife 1. Houve diferença significativa na riqueza de espécies de lagartos entre as campanhas realizada sendo a riqueza maior obtida a partir da 38 campanha de campo, em abril-maio de 2005. Não houve diferença significativa na riqueza de espécies e no número de indivíduos de lagartos em relação à margem do reservatório. Houve diferença significativa e positiva da riqueza de espécies de lagartos em relação ao tamanho da ilha. Não houve diferença significativa na abundância de lagartos em relação ao tamanho das ilhas. Houve diferença significativa entre a riqueza de lagartos em relação ao isolamento da ilha, sendo esta menor nas ilhas mais isoladas. Não houve diferença significativa entre a abundância de lagartos em relação ao isolamento da ilha. Não houve diferença significativa da riqueza de espécies em relação à abertura do dossel e ao volume de serrapilheira. Houve diferença significativa e positiva entre a riqueza de espécies em relação à densidade de troncos caídos e de árvores vivas. Não houve diferença significativa da abundância de indivíduos em relação aos parâmetros de estrutura da vegetação analisados neste estudo. Não houve diferença na composição de espécies da comunidade de lagartos nas ilhas em relação às margens do reservatório, indicando que o rio Tocantins não é uma barreira geográfica para a distribuição deste grupo. / Appear of many studies published in tropical regions showing the effect on forest fragmentation and landscape isolation in biotic communities most studies have been made in continental regions. The impact of fragmentation and isolation of landscape in hydroelectric artificial reservoir are still poorly studies in the Amazonian. This study was done in island forest remain fragments created by the construction of the Tucurui Hydroelectric dam in the Para State, Brazil. The objectives of the study is to compare the islands on both sides of the reservoir in relation to the total size, total core area size, plot shape and degree of isolation to demonstrated the role of island to protected the local biota in landscape level and assess the species richness, abundance and species composition of the communities of lizard in the islands in local scale. At landscape level were chosen 199 islands in both margin of reservoir using satellite image of 2005. The total size of island varied from 3 to 1,768 hectares, being that 40% of island has less than 10 hectares in size. The islands have a significant loss of size, varying from 22% to 100% in relation to edge effects. There is no significant difference of the total size, total core area size and total edge of islands in relation to reservoir margins. However, the islands situated in the left margin of reservoir have high degree of isolation in compare to island from right margin. Most of the island analyzed in the Tucurui reservoir have small sizes, high loss of total area due to edge effects and irregular plot shape, all contributing. At local scale the lizard community was sampled in five field expedition carried out from January to July of 2005, using two methods of collect, transects and traps of interception and fall. We selected 12 islands based on total size, degree of isolation and position in relation to reservoir margin. We recorded 837 individuals of lizard distributed in 16 species. The most abundant species were Gonatodes humeralis and Coleodactylus amazonicus (Gekkonidae). The curve of total number of species in relation to field expedition reached the asymptote, showing that the five expeditions were sufficient to determine local species richness in the sampled island, corresponding to 84% of the total number of species determined by Jackknife 1 species richness estimator. There is significant difference in the species richness in relation to field expeditions, being highest species richness obtained from the third field expedition carried out from April to May of 2005. There is no significant difference in the species richness and number of individuals in relation to reservoir margins. There is significant and positive difference between the species richness in relation to size of island. There is no significant difference in the abundance of lizards in relation to size of island. There is significant difference in the species richness of lizards in relation to degrees of isolation of island, being the isolation lower in the more remote islands. However, the abundance of lizards in relation to degree of isolation of islands was not significant. There is no significant difference in the species richness in relation to open canopy and volume of litter. There is significant and positive difference between the species richness in relation to density of trunk falls and trees lives. There is no difference in the abundance of lizards in relation to forest structure parameters analyzed in the study. Finally there is no difference in the species composition of lizards in relation to reservoir margins, indicating that the Tocantins River in the sampled area analyzed in the study is not one important biogeography barrier to this group.
|
3 |
Estudo do impacto socioeconômico da piscicultura em tanques-rede no reservatório da UHE Tucuruí-PA: o caso do Projeto IpiráARAÚJO, Eduardo André Duarte de 26 August 2014 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2015-06-08T19:15:47Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_EstudoImpactoSocioeconomico.pdf: 7221501 bytes, checksum: 231f2990988cd79f1ba11a660ee498c3 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2015-06-16T14:19:31Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_EstudoImpactoSocioeconomico.pdf: 7221501 bytes, checksum: 231f2990988cd79f1ba11a660ee498c3 (MD5) / Made available in DSpace on 2015-06-16T14:19:31Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_EstudoImpactoSocioeconomico.pdf: 7221501 bytes, checksum: 231f2990988cd79f1ba11a660ee498c3 (MD5)
Previous issue date: 2014 / A presente dissertação avalia o desenvolvimento da piscicultura em tanques-rede no reservatório da Usina Hidrelétrica de Tucuruí, no Estado do Pará, a partir de um estudo de caso: o projeto de piscicultura Ipirá, criado por meio um acordo firmado entre a Centrais Elétricas do Norte do Brasil – Eletrobras Eletronorte e um conjunto de famílias que tiveram seus modos de vida impactados pela construção da Hidrelétrica de Tucuruí, como alternativa para a geração de emprego e renda. Avalia-se, mas especificamente qual o impacto do projeto na melhoria das condições de vida das famílias atendidas pelo mesmo sob a perspectiva socioeconômica. Para alcançar os objetivos desse trabalho, utilizou-se além do estudo de caso, o modelo sistêmico para a aqüicultura, em especial os cálculos dos índices para a avaliação da sustentabilidade socioeconômica da aquicultura - IDES, como procedimentos metodológicos. Observou-se que o projeto de piscicultura Ipirá mostra-se potencialmente sustentável do ponto de vista socioeconômico (0,649). Os indicadores aspectos sanitários (0,123), lazer (0,113) e saúde (0,110), apresentaram em ordem decrescente, as principais contribuições na composição do IDES, ao passo que os indicadores renda (0,040) e habitação (0,79), essenciais para a manutenção familiar e condições de bem estar do ser humano, apresentaram os piores resultados. Conclui-se, a partir dos resultados gerados, que o projeto de piscicultura Ipirá não conseguiu alcançar seu objetivo principal: geração de emprego e renda, e demonstra-se não influenciar significativamente na melhoria das condições de vida das famílias atendidas, o que é reforçado pelos dados levantados em campo, onde 86% dos entrevistados sobrevivem com salário igual e menor que 1 salário mínimo mensal, complementado pelo auxílio do seguro defeso e o bolsa família. Por fim, ressalta-se a relevância do projeto Ipirá como um case de política sócio-ambiental com potencial para dinamizar a economia local e em uma perspectiva mais otimista se tornar um modelo a ser replicado e abranger todos os municípios do entorno do reservatório da Usina Hidrelétrica de Tucuruí, desde que as falhas na implantação e no seu gerenciamento sejam sanadas e as devidas providenciais sejam tomadas, como as apontadas pelo presente estudo. / The present dissertation evaluates the development of pisciculture in net tanks in the reservoir of the hydroelectric plant of Tucuruı, State of Pará, from a case study: the project of pisciculture Ipirá, created from an agreement between the Central Electric of Northern Brazil - Eletronorte and a set of families who have had their livelihoods impacted by the construction of hydroelectric of Tucuruı as an alternative for the generation of employment and income. Evaluates, more specifically, the impact of the project on improving the living conditions of the families served by the same under the socioeconomic perspective. To achieve the objectives of this study, we used beyond the case study, the systemic model for aquaculture, especially the calculation of indices for assessing the socioeconomic sustainability of aquaculture - IDES, as the methodological procedures. It was observed that the pisciculture project Ipirá shown to be potentially sustainable from a socioeconomic perspective (0.649). The indicators of health aspects (0,123), leisure (0,113) and health (0.110), showed in descending order, the main contributions in the composition of IDES, while the indicators income (0,040) and housing (0.79), essential for family maintenance and welfare conditions of the human being, showed the worst results. In conclusion, the results generated from the pisciculture project Ipirá, whose main objective is the generation of employment and income, failed in its totality achieve its main objective and proves to be not significantly influence the improvement of living conditions of families served, which is reinforced by the data collected in the field, where 86% of those interviewed survives with equal and less than one monthly minimum wage, supplemented by the help of the "bolsa família" and closures secure. Finally, we emphasize the relevance of Ipirá project as a case of socio-environmental policy with the potential to boost the local and a more optimistic outlook economy to become a model to be replicated and cover all the surrounding municipalities of Plant Reservoir Tucuruí, since failures in implementation and its management are resolved and payable are taken providential, as indicated by this study.
|
4 |
Simulação e dimensionamento ótimo de sistemas autônomos híbridos com reservatórios hidrelétricosVega, Fausto Alfredo Canales January 2015 (has links)
O interesse mundial e os investimentos em fontes renováveis de energia têm aumentado consideravelmente nos últimos anos. Estas tecnologias têm a vantagem de aproveitar os recursos disponíveis localmente, reduzindo a dependência de fontes externas. Entretanto, um dos principais problemas associados a muitas das tecnologias de energias renováveis é sua imprevisibilidade ou intermitência. O armazenamento de energia é a técnica mais utilizada para moderar estas intermitências. Para aproveitamento em grande escala, os reservatórios hidrelétricos (de usinas hidrelétricas convencionais com reservatório e usinas hidrelétricas reversíveis) representam a tecnologia mais madura e amplamente aproveitada para armazenamento de energia elétrica na forma de energia potencial no volume de água. Isto faz destes uma opção importante a ser incluída no projeto de um sistema autônomo híbrido de geração de energia. Segundo diferentes autores consultados, o software HOMER (Hybrid Optimization Model for Electric Renewables) é a ferramenta mais amplamente utilizada em pesquisas relacionadas à simulação e configuração ótima deste tipo de sistemas. Esta tese apresenta um conjunto de procedimentos para determinar, em nível de pré-viabilidade, a configuração ótima (em termos do custo presente líquido) e o conjunto de arranjos viáveis de um sistema autônomo de geração de energia incluindo fontes renováveis intermitentes e reservatórios hidrelétricos. O software HOMER é aplicado na simulação e avaliação dos sistemas híbridos dos estudos de caso hipotéticos do presente trabalho, utilizados para validar os métodos propostos. Estes exemplos foram criados a partir de dados reais relacionados ao Estado de Rio Grande do Sul. Os procedimentos descritos são aplicáveis a qualquer região do mundo onde exista um local com potencial para reservatórios hidrelétricos, assim como dados de disponibilidade e custos relacionados a fontes renováveis intermitentes. Além de determinar a configuração ótima e o conjunto de arranjos viáveis, os resultados obtidos indicam que os procedimentos descritos podem ajudar na definição da melhor utilização de um local com potencial hidrelétrico. Igualmente, permitem estimar a quantidade de eletricidade excedente que poderia ser recuperada através de usinas reversíveis. Os resultados mostram que configuração ótima depende de muitos fatores, tais como restrições hidrológicas, a carga a ser atendida e o custo de geração de cada fonte. / Global interest and investments in renewable energy sources has increased considerably in recent years. These technologies have the advantage of using locally available resources, reducing dependence on external energy sources. However, most renewable energy technologies suffer from an intermittent characteristic due to the diurnal and seasonal patterns of the natural resources needed for power generation. Energy Storage is the most used technique to buffer this intermittency. For large-scale applications, hydropower reservoirs (of conventional and pumped storage plants) are the most mature and the most widely employed technology for electricity storage in the form of potential energy. For this reason, a hydropower reservoir is a suitable option to consider including in an autonomous hybrid power system. According to many authors, the HOMER model (Hybrid Optimization Model for Electric Renewables) is the most widely used tool in research studies related to simulation and optimal design of this type of systems. This thesis presents some procedures to define, as a pre-feasibility assessment, the optimal configuration (in terms of Net Present Cost) and set of feasible designs of an autonomous hybrid power system that includes intermittent renewable energy sources and hydropower reservoirs. The HOMER software is used for simulating and evaluating the hybrid power systems of the hypothetical case studies, used to validate the proposed methods. These examples were created based on real data related to the State of Rio Grande do Sul, Brazil. The procedures described can be adapted to any other region of the world where exists a site suitable for the construction of hydropower reservoirs, along with available data regarding intermittent renewable sources and generation costs. Besides defining the optimal configuration and the set of feasible designs, the results indicate that the procedures explained could help in the definition of the best use of a site with hydropower potential. Likewise, these methods can also be used to estimate how much excess electricity can be recovered by means of pumped storage hydropower. The results show that the optimal system design depends on many factors such as hydrological constraints, average load to serve and energy cost of each source.
|
5 |
Simulação e dimensionamento ótimo de sistemas autônomos híbridos com reservatórios hidrelétricosVega, Fausto Alfredo Canales January 2015 (has links)
O interesse mundial e os investimentos em fontes renováveis de energia têm aumentado consideravelmente nos últimos anos. Estas tecnologias têm a vantagem de aproveitar os recursos disponíveis localmente, reduzindo a dependência de fontes externas. Entretanto, um dos principais problemas associados a muitas das tecnologias de energias renováveis é sua imprevisibilidade ou intermitência. O armazenamento de energia é a técnica mais utilizada para moderar estas intermitências. Para aproveitamento em grande escala, os reservatórios hidrelétricos (de usinas hidrelétricas convencionais com reservatório e usinas hidrelétricas reversíveis) representam a tecnologia mais madura e amplamente aproveitada para armazenamento de energia elétrica na forma de energia potencial no volume de água. Isto faz destes uma opção importante a ser incluída no projeto de um sistema autônomo híbrido de geração de energia. Segundo diferentes autores consultados, o software HOMER (Hybrid Optimization Model for Electric Renewables) é a ferramenta mais amplamente utilizada em pesquisas relacionadas à simulação e configuração ótima deste tipo de sistemas. Esta tese apresenta um conjunto de procedimentos para determinar, em nível de pré-viabilidade, a configuração ótima (em termos do custo presente líquido) e o conjunto de arranjos viáveis de um sistema autônomo de geração de energia incluindo fontes renováveis intermitentes e reservatórios hidrelétricos. O software HOMER é aplicado na simulação e avaliação dos sistemas híbridos dos estudos de caso hipotéticos do presente trabalho, utilizados para validar os métodos propostos. Estes exemplos foram criados a partir de dados reais relacionados ao Estado de Rio Grande do Sul. Os procedimentos descritos são aplicáveis a qualquer região do mundo onde exista um local com potencial para reservatórios hidrelétricos, assim como dados de disponibilidade e custos relacionados a fontes renováveis intermitentes. Além de determinar a configuração ótima e o conjunto de arranjos viáveis, os resultados obtidos indicam que os procedimentos descritos podem ajudar na definição da melhor utilização de um local com potencial hidrelétrico. Igualmente, permitem estimar a quantidade de eletricidade excedente que poderia ser recuperada através de usinas reversíveis. Os resultados mostram que configuração ótima depende de muitos fatores, tais como restrições hidrológicas, a carga a ser atendida e o custo de geração de cada fonte. / Global interest and investments in renewable energy sources has increased considerably in recent years. These technologies have the advantage of using locally available resources, reducing dependence on external energy sources. However, most renewable energy technologies suffer from an intermittent characteristic due to the diurnal and seasonal patterns of the natural resources needed for power generation. Energy Storage is the most used technique to buffer this intermittency. For large-scale applications, hydropower reservoirs (of conventional and pumped storage plants) are the most mature and the most widely employed technology for electricity storage in the form of potential energy. For this reason, a hydropower reservoir is a suitable option to consider including in an autonomous hybrid power system. According to many authors, the HOMER model (Hybrid Optimization Model for Electric Renewables) is the most widely used tool in research studies related to simulation and optimal design of this type of systems. This thesis presents some procedures to define, as a pre-feasibility assessment, the optimal configuration (in terms of Net Present Cost) and set of feasible designs of an autonomous hybrid power system that includes intermittent renewable energy sources and hydropower reservoirs. The HOMER software is used for simulating and evaluating the hybrid power systems of the hypothetical case studies, used to validate the proposed methods. These examples were created based on real data related to the State of Rio Grande do Sul, Brazil. The procedures described can be adapted to any other region of the world where exists a site suitable for the construction of hydropower reservoirs, along with available data regarding intermittent renewable sources and generation costs. Besides defining the optimal configuration and the set of feasible designs, the results indicate that the procedures explained could help in the definition of the best use of a site with hydropower potential. Likewise, these methods can also be used to estimate how much excess electricity can be recovered by means of pumped storage hydropower. The results show that the optimal system design depends on many factors such as hydrological constraints, average load to serve and energy cost of each source.
|
6 |
Simulação e dimensionamento ótimo de sistemas autônomos híbridos com reservatórios hidrelétricosVega, Fausto Alfredo Canales January 2015 (has links)
O interesse mundial e os investimentos em fontes renováveis de energia têm aumentado consideravelmente nos últimos anos. Estas tecnologias têm a vantagem de aproveitar os recursos disponíveis localmente, reduzindo a dependência de fontes externas. Entretanto, um dos principais problemas associados a muitas das tecnologias de energias renováveis é sua imprevisibilidade ou intermitência. O armazenamento de energia é a técnica mais utilizada para moderar estas intermitências. Para aproveitamento em grande escala, os reservatórios hidrelétricos (de usinas hidrelétricas convencionais com reservatório e usinas hidrelétricas reversíveis) representam a tecnologia mais madura e amplamente aproveitada para armazenamento de energia elétrica na forma de energia potencial no volume de água. Isto faz destes uma opção importante a ser incluída no projeto de um sistema autônomo híbrido de geração de energia. Segundo diferentes autores consultados, o software HOMER (Hybrid Optimization Model for Electric Renewables) é a ferramenta mais amplamente utilizada em pesquisas relacionadas à simulação e configuração ótima deste tipo de sistemas. Esta tese apresenta um conjunto de procedimentos para determinar, em nível de pré-viabilidade, a configuração ótima (em termos do custo presente líquido) e o conjunto de arranjos viáveis de um sistema autônomo de geração de energia incluindo fontes renováveis intermitentes e reservatórios hidrelétricos. O software HOMER é aplicado na simulação e avaliação dos sistemas híbridos dos estudos de caso hipotéticos do presente trabalho, utilizados para validar os métodos propostos. Estes exemplos foram criados a partir de dados reais relacionados ao Estado de Rio Grande do Sul. Os procedimentos descritos são aplicáveis a qualquer região do mundo onde exista um local com potencial para reservatórios hidrelétricos, assim como dados de disponibilidade e custos relacionados a fontes renováveis intermitentes. Além de determinar a configuração ótima e o conjunto de arranjos viáveis, os resultados obtidos indicam que os procedimentos descritos podem ajudar na definição da melhor utilização de um local com potencial hidrelétrico. Igualmente, permitem estimar a quantidade de eletricidade excedente que poderia ser recuperada através de usinas reversíveis. Os resultados mostram que configuração ótima depende de muitos fatores, tais como restrições hidrológicas, a carga a ser atendida e o custo de geração de cada fonte. / Global interest and investments in renewable energy sources has increased considerably in recent years. These technologies have the advantage of using locally available resources, reducing dependence on external energy sources. However, most renewable energy technologies suffer from an intermittent characteristic due to the diurnal and seasonal patterns of the natural resources needed for power generation. Energy Storage is the most used technique to buffer this intermittency. For large-scale applications, hydropower reservoirs (of conventional and pumped storage plants) are the most mature and the most widely employed technology for electricity storage in the form of potential energy. For this reason, a hydropower reservoir is a suitable option to consider including in an autonomous hybrid power system. According to many authors, the HOMER model (Hybrid Optimization Model for Electric Renewables) is the most widely used tool in research studies related to simulation and optimal design of this type of systems. This thesis presents some procedures to define, as a pre-feasibility assessment, the optimal configuration (in terms of Net Present Cost) and set of feasible designs of an autonomous hybrid power system that includes intermittent renewable energy sources and hydropower reservoirs. The HOMER software is used for simulating and evaluating the hybrid power systems of the hypothetical case studies, used to validate the proposed methods. These examples were created based on real data related to the State of Rio Grande do Sul, Brazil. The procedures described can be adapted to any other region of the world where exists a site suitable for the construction of hydropower reservoirs, along with available data regarding intermittent renewable sources and generation costs. Besides defining the optimal configuration and the set of feasible designs, the results indicate that the procedures explained could help in the definition of the best use of a site with hydropower potential. Likewise, these methods can also be used to estimate how much excess electricity can be recovered by means of pumped storage hydropower. The results show that the optimal system design depends on many factors such as hydrological constraints, average load to serve and energy cost of each source.
|
Page generated in 0.0826 seconds