• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 73
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 73
  • 73
  • 42
  • 27
  • 22
  • 17
  • 14
  • 13
  • 10
  • 9
  • 9
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da resistência de união de um sistema adesivo universal à dentina superficial sob teste de microtração

Soares, Idiane Bianca Lima January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T20:46:19Z (GMT). No. of bitstreams: 1 327728.pdf: 1775198 bytes, checksum: 71fd40fde69664480e569ccd87e6e444 (MD5) Previous issue date: 2014 / Este estudo teve como objetivo avaliar a resistência de união adesiva sob teste de microtração à dentina humana, comparando um sistema adesivo universal e suas diferentes técnicas de aplicação com um sistema adesivo convencional. Vinte terceiros molares foram divididos aleatoriamente em 4 grupos, variando o sistema adesivo e a técnica de acordo com o fabricante, seguido da reconstrução da porção coronal com resina composta Filtek Z350: G1- Adper Single Bond, com condicionamento ácido; G2- Single Bond Universal, modo autocondicionante; G3- Single Bond Universal, modo condicionamento ácido (dentina úmida); G4-Single Bond Universal, modo condicionamento ácido (dentina ressecada). Para a análise estatística dos dados, foi empregada análise de variância (Anova) (p=0,05). As comparações individuais foram realizadas com teste de diferença significativa de Tukey (HSD) (p=0,05). Os resultados revelaram que não houve diferenças estatísticas entre os grupos avaliados em relação aos valores de microtração. Pode-se concluir que o adesivo Single Bond Universal apresentou resultados estatisticamente semelhantes ao adesivo Adper Single Bond, independentemente do modo utilizado.
12

A influência das técnicas de remineralização biomimética da dentina na durabilidade da união dentina-resina

Nogueira, Fernanda Santoro 03 March 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2017. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2017-04-19T15:49:50Z No. of bitstreams: 1 2017_FernandaSantoroNogueira.pdf: 1185479 bytes, checksum: d994ba44e6dfe5527d91eedf16d9b748 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2017-04-27T21:46:52Z (GMT) No. of bitstreams: 1 2017_FernandaSantoroNogueira.pdf: 1185479 bytes, checksum: d994ba44e6dfe5527d91eedf16d9b748 (MD5) / Made available in DSpace on 2017-04-27T21:46:52Z (GMT). No. of bitstreams: 1 2017_FernandaSantoroNogueira.pdf: 1185479 bytes, checksum: d994ba44e6dfe5527d91eedf16d9b748 (MD5) / Várias estratégias têm sido desenvolvidas com o intuito de promover a remineralização da dentina através de mecanismos biomiméticos. O objetivo desta revisão foi de avaliar como as distintas técnicas de remineralização biomimética influenciam na longevidade da união dentina-resina. A pesquisa foi realizada nas bases de dados Pubmed, Lilacs, Cochrane, Web of Science, Scopus e, como fonte de literatura cinzenta, pesquisa no Google Scholar. Na busca foram encontrados 1837 artigos, dos quais 1731 foram excluídos após a seleção final. Após leitura completa dos estudos, 16 artigos foram incluídos nesta revisão. Todos os estudos foram submetidos à análise de qualidade pelo método GRADE e análise de risco de viés pelo CRIS Guideline. Sete artigos relataram o uso de análogos biomiméticos e / ou moléculas polianiônicas como fonte de cálcio e um meio para favorecer a remineralização. Seis estudos descreveram métodos que utilizam agentes do tipo cross-linkers, tais como proantocianidina e clorexidina. Dois estudos descreveram a utilização do peptídeo E8DS e a utilização de ácido meta-fosfórico. A atual revisão sistemática confirma o potencial das técnicas de remineralização biomimética em favorecer a longevidade da união dentina -resina. De acordo com os achados desta revisão, são necessários mais estudos que avaliem os efeitos a longo prazo, os mecanismos individuais envolvidos em cada abordagem de remineralização biomimética e a aplicabilidade clínica. / Various strategies have been developed in order to promote the remineralization of dentin by the use of biomimetic mechanisms.The aim of this systematic review is to evaluate how these strategies influence the durability of the resin-dentin bond. Studies were gathered by searching the databases Pubmed, Lilacs, Cochrane, Web of Science, Scopus and, as a grey literature, in Google Scholar. A total of 1837 studies were found, and 1731 were excluded after initial screening. After retrieving the full text, 16 were included in this systematic review. All studies were submitted to quality assessment and risk of bias analyses by the GRADE method and CRIS Guideline, respectively. Seven papers reported the use of biomimetics analogs and/or polyanionic molecules as a calcium source and as a path to favor remineralization. Six studies have described methods that use cross-linking agents, such as proanthocyanidin and chlorhexidine.Two studies described the use of peptide E8DS and the use of meta-phosphoric acid. The present systematic review confirms the potential value of the biomimetic techniques in favoring the durability of dentin-resin bond. According to the findings, it is required more studies that evaluate the long-terms effects, the individual mechanisms involved in each approach and the clinical applicability.
13

Compatibilidade biologica de resina resorcina-formaldeido quando aplicada sobre dentina em pre-molares humanos. Avaliação em microscopia optica e eletronica de transmissão

Costa, Carlos Alberto de Souza 20 November 1996 (has links)
Orientador: Jose Merzel / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-21T20:14:26Z (GMT). No. of bitstreams: 1 Costa_CarlosAlbertodeSouza_D.pdf: 2234718 bytes, checksum: 6c1ddc289ed7c1484e781f2d428e2831 (MD5) Previous issue date: 1996 / Resumo: o objetivo deste trabalho foi avaliar a compatibilidade biológica da resina resorcina-formaldeído quando aplicada diretamente sobre dentina. Trinta e seis premolares humanos íntegros, indicados para extração por motivos ortodônticos, foram divididos em três grupos: no grupo experimental, 22 cavidades classe V foram preparadas e forradas com a resina resorcina formaldeído; no grupo controle I, 8 cavidades foram forradas com cimento de hidróxido de cálcio. As cavidades destes dois grupos foram restauradas com amálgama. No grupo controle 11, 6 premolares foram mantidos íntegros. Os dentes foram extraídos após 7, 15, 30 e 120 dias da realização das restaurações e cortes histológicos foram preparados para avaliação em M.E.T.. Outros ainda, com 6 Ilm de espessura, foram corados com hematoxilina e eosina, tricrômico de Masson e pela técnica de Brown e Brenn para evidenciar bactérias. No grupo experimental, aos 7 dias, observou-se desarranjo da camada odontoblástica, aspiração de corpos celulares para o interior dos túbulos dentinários, degeneração hidrópica das células, hialinização do interstício, necrose e neutrófilos. Aos 15 e 30 dias, a intensidade das alterações pulpares diminuiu. Aos 120 dias, houve reparação pulpar, com deposição de dentina reacional. No grupo controle I, houve discreta alteração pulpar aos 7 dias, porém nos demais períodos o tecido pulpar exibia características normais, semelhante aos dentes não tratados do grupo controle 11. Não houve relação entre a irjfnsidade da reação pulpar com a espessura de dentina remanescente, nem com a presença de bactérias coradas nas paredes cavitárias ou no interior dos túbulos dentinários. A resina resorcina-formaldeído, usada como forrador cavitário, causou significante reação pulpar aos 7 e 15 dias. Novas pesquisas "in vivo" e "in vitro" devem ser realizadas para que seja avaliada a biocompatibilidade da resina quando aplicada. sobre variados substratos dentinários, permitindo determinar outras possíveis indicações de uso deste produto em teste / Abstract: The purpose of this investigation was to evaluate the biological compatibility of a resorcin-formaldehyde resin when applied directly on dentin cavity floor. Thirty six healthy human premolars due to be extracted for orthodontic reasons were selected for the study. This sample was divided into three groups: in experimental group, class V cavities were prepared, lined with resorcin formaldehyde resin; in control group I, the cavities were lined with calcium hydroxide cements. The cavities were restored with amalgam; in control group 11, the remaining 6 prelomars were used as a negative control, having no treatment. The teeth were extracted at 7, 15, 30 and 120 days afier the placement of restorations and sections were obtained, stained with haematoxylin and eosin, Masson's Trichrome, with the Brown and Brenn technique for the identification of bacteria. The specimens were evaluated in O.M. and T.E.M. and histological observations showed at 7 day for experimental group, odontoblastic disappearance with aspiration into dentinal tubules, hidropic degeneration cells, hyalin alteration, necrosis and neutrophils in the region. At 15 and 30 days was" determined that the intensity of the reactions decreased with time, so at 120 days was observed the pulpal healing with reactional dentinal deposition. For the control group I the histological observation showed slight pulpal reaction at 7 days but in the others periods the pulpal tissue exibed normal characteristics, similar the teeth no treated for control group 11. This study showed neither a potential relationship between the intensity of the reactions and the thickness of the residual dentin nor between the intensity of reactions and the presence of bacteria on the cavity walls or into the dentinal tubules. The resorcin-formaldehyde resin, used as cavity liner, showed a significant pulpal reaction at 7 and 15 days. So, more "in vivo" and "in vitro" studies should be made to observe pulp reactions when resin is applied on enamel or cement / Doutorado / Biologia e Patologia Buco-Dental / Doutor em Ciências
14

Efeito da umidade relativa na estabilidade dimensional de diferentes materiais restauradores

Soares, Anadelia Borges 11 September 1997 (has links)
Orientador: Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-22T20:45:34Z (GMT). No. of bitstreams: 1 Soares_AnadeliaBorges_M.pdf: 5590690 bytes, checksum: b4038ac37f3102d78f8ba65bdda22c60 (MD5) Previous issue date: 1997 / Resumo: Os cimentos de ionômero de vidro são dependentes do equilíbrio hídrico e apresentam contração durante a reação de geleificação. O propósito deste estudo foi avaliar o efeito da umidade relativa (U.R.) na estabilidade dimensional dos cimentos restauradores ionoméricos Vidrion R (SS White) e Chelon Fil (ESPE), modificados por resina (Vitremer-3M), duas resinas modificadas por poliácidos (Compoglass/ Vivadent e Dyract /Dentsply) e a resina composta Z100 (3M). Os corpos-de-prova foram obtidos em matrizes metálicas circulares medindo 6 mm de diâmetro por 2 mm de espessura. Foram confeccionados dez corpos-de-prova para cada material, ?endo cinco deles em ambiente controlado à temperatura de 23° :!: 1°C e 50 :!: 5% de U. R. e os outros cinco à mesma temperatura e à umidade relativa de 80%. Os materiais foram manipulados de acordo com as instruções dos fabricantes. Logo após os procedimentos de confecção, es corpos-de-prova foram armazenados a 37°C e 100% de U.R., durante uma hora. Decorrido o tempo de armazenagem, a interface matriz metálica-material restaurador foi mensurada através de uma ocular micrométrica com. tambor graduado acoplada na objetiva de um fotomicroscópio. Os valores obtidos foram submetidos a análise de variância e ao teste de Tukey em nível de 5% de significância. Os materiais Vidrion R e Chelon Fil apresentaram valores médios das fendas formadas na interface matriz-material restaurador significativamente maiores no ambiente de 50% de U.R, em relação ao ambiente com 80% de U.R. Os valores apresentados pelos demais materiais não diferiram estatisticamente entre si (p>0,05) e foram inferiores aqueles dos cimentos Vidrion R e Chelon Fi!. Os valores médios das fendas apresentados por todos os materiais foram significativamente diferentes entre si (p<0,05) nos ambientes de 50% ou 80% de U.R. na seguinte ordem decrescente: Vidrion R > Chelon Fil > Z100 > Vitremer > Compoglass > Dyract. Todos os materiais apresentaram fendas, independentes da composição e umidade relativa / Abstract: The purpose of this study was evaluate the effect of relative humidity (RH) on the dimensional stability of glass ionomer cements, Vidrion R (S.S.White) and Chelon Fil (ESPE), and one resin modified glass ionomer (Vitremer-3M), two polyacid modified resins (CompoglassNivadent and Dyract/Dentsply), and the composite resin Z 100 (3M). The specimens were obtained from metallic rounded molds (6mm diameter x 2mm thick). Ten specimens of each material were made, five of them on enviroment at 23° :t 1 ° C and 50 :t 5% RH and the remaining at 23° :t 1 ° C and RH of 80%. The materiais were manipulated according to the manufacturer's instructions. The specimens were stored at 37°C and 100 % RH for one hour. After the storage period, the gaps that were formed in materialmetallic mold interface were measured .through a graduated lens adapted to a microscope. The values were submitted to variance analysis and Tukey's test (p ~ 0,05). At 50% RH, gaps values for Vidrion R and Chelon . Fil were significatly higher than at 80% RH. The values of other materiais were similar at both RH, and gaps values were lower than Vidrion R and Chelon Fi!. Ali the materiais showed different gaps values (p < 0,05) at both relatives humidities according to the following decreasing range: Vidrion R > Chelon Fil > Z 100 > Vitremer > Compoglass > Dyract. Ali materiais showed gaps, despite of composition and relative humidity / Mestrado / Materiais Dentarios / Mestre em Ciências
15

Avaliação in vitro da infiltração marginal e da microdureza em restaurações classe II realizadas com diferentes sistemas restauradores e tecnicas de inserção

Briso, Andre Luiz Fraga 29 March 2001 (has links)
Orientadores: Luiz Andre Freire Pimenta, Renato Herman Sundfeld / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T13:03:24Z (GMT). No. of bitstreams: 1 Briso_AndreLuizFraga_D.pdf: 13831318 bytes, checksum: 7d7c099568e1f19dd69b93aaf26115c6 (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar a microinfiltração e a microdureza Knoop em restaurações classe II, quando empregadas 5 combinações de sistemas restauradores (Bond-1® Prime/Adesivo + ALERT; Bond -1® Prime/Adesivo + FLOW-IT + ALERT; Etch & Prime® 3.0 + DEFINITE; Prime & Bond NT + SUREFIL; e Solid Bond P + Solid Bond S + CHARlSMA) e 2 técnicas de inserção (incrementos horizontais e de incremento único). Para tanto, 230 cavidades tipo "slot" vertical confeccionadas nas faces mesial e distal com margens em dentina foram divididas aleatoriamente em 10 grupos, segundo o sistema restaurador e a técnica empregada. Após a execução das restaurações e do polimento, os dentes foram sujeitos a 2000 ciclos térmicos (5 ± 2°C e 55 ± 2°C). Em seguida, foram cobertos com esmalte para unha, com exceção das margens cervicais e do milímetro que as circunscreviam. Logo após, os dentes foram imersos em solução de azul de metileno a 2% por 4 horas, sendo, em seguida, seccionados e avaliados conforme o grau e o padrão de penetração da solução evidenciadora. Os cortes obtidos foram utilizados para análise da microdureza em diferentes profundidades. Para a avaliação da microinfiltração empregou se o teste de Kruskal-W allis, enquanto que para os valores do padrão de penetração foi usado o teste Exato de Fisher. A análise da microdureza foi submetida aos testes ANOV A e de Tukey. Observou-se que: nenhuma técnica ou material restaurador foi capaz de impedir a ocorrência de infiltração marginal em restaurações classe II, com margens em dentina; a variação das técnicas restauradoras não afetou o desempenho da resina de baixa viscosidade, FLOW-IT, associada ao material ALERT no controle da microinfiltração; todos materiais analisados se comportaram de forma semelhante no controle da infiltração marginal, quando se empregou a técnica de incremento único; a resina composta SUREFIL controlou de forma mais efetiva a ocorrência de infiltração marginal quando a técnica incremental foi empregada; a penetração de corante em tecido dentinário não foi influenciada pela técnica restauradora; o material ALERT não foi capaz de ser polimerizado de forma uniforme em incrementos superiores a 2mm, com 120 segundos de exposição à luz halógena / Abstract: The objective of this study was to evaluate the microleakage and the Knoop microhardness in class II restorations when using 5 combinations of restorative systems (Bond - 1® Prime/Adesive + ALERT; Bond - 1® Prime/Adesive + FLOW-IT + ALERT; Etch & Prime® 3.0 + DEFINITE; Prime & Bond NT + SUREFIL; and Solid Bond P + Solid Bond S + CHARISMA) and 2 restorative techniques (horizontal increments and bulk insertion). The 230 cavities with dentine margins were randomly divided into 10 groups according to the restorative systems and the technique used. After the restorative / Doutorado / Dentística / Doutor em Clínica Odontológica
16

Influencia da escovação mecanica na rugosidade de superficie e dureza knoop de materiais restauradores polimericos, sob diferentes modos de polimerização

Belloti, Haglay Palandi de Oliveira 26 November 1999 (has links)
Orientador: Lourenço Correr Sobrinho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T15:33:05Z (GMT). No. of bitstreams: 1 Belloti_HaglayPalandideOliveira_M.pdf: 4807571 bytes, checksum: c6c17eb016636c47c33b5dff9851931b (MD5) Previous issue date: 1999 / Resumo: o propósito deste estudo foi investigar a influência da escovação mecânica na dureza Knoop e rugosidade de superfície do Charisma e Artglass sob diferentes modos de polimerização. Quarenta amostras com 8mm de diâmetro foram feitas utilizando uma matriz plástica com 2,Omm de espessura, sendo o Charisma polimerizado por 40 segundos. Dez receberam polimerização adicional pela água a 1000 C, por 5 minutos. Dez amostras do Charisma e dez do Artglass foram polimerizadas no aparelho Uni-XS por 180 segundos. Todas as amostras foram armazenadas em água a 37 :t 1 °C por 24 horas. Após esse período, cinco amostras de cada tratamento receberam acabamento e polimento e 5 não receberam (controle). A dureza Knoop foi aferida no aparelho Shimadzu HMV-2000, com carga de 50 9 por 30 segundos. Cinco penetrações foram feitas em cada amostrá A rugosidade foi verificada com o aparelho Prazis-Rug, antes e após as amostras serem submetidas a 30.000 'ciclos numa máquina de escovação Equilabor. Foram feitas três leituras em cada corpo-de-prova, totalizando 120 leituras. Os resultados foram analisados estatisticamente pelo teste de Tukey (5%), e indicaram que: 1) A rugosidade do Charisma polimerizado por luz (0,146/lm) foi superior em relação ao Charisma com polimerização adicional pelo calor (0,132/lm), ao Charisma polimerizado no aparelho Uni-XS (0,088/lm) e ao Artglass (O,096/lm) antes da escovação sem polimento, enquanto o Artglass foi mais rugoso após a escovação; 2) A rugosidade após o polimento (antes e após a escovação) foi significantemente maior no Artglass (0,358f..1.m) do que no Charisma polimerizado no aparelho Uni-XS (0,214~m); 3) A dureza Knoop para o Charisma-aparelho Uni XS (48,84 KHN) e Artglass (42,53 KHN) sem polimento antes da escavação foi significantemente maior do que no Charisma-Iuz (34,78 KHN) e o Charisma calor (29,04 KHN). Após o polimento e escovação, a dureza do Charisma-aparelho UniXS (54,70 KHN) e do Charisma-calor (53,24 KHN) foi significantemente maior do I que o Artglass (45,44 KHN) e o Charisma-Iuz (34,46 KHN); 4) Após a escovação, I os Charisma com polimerização adicional pelo calor, Artglass e Charisma I polimerizado no aparelho Uni-XS foram estatisticamente superiores ao Charisma polimerizado por luz (p<O,05), sem polimento. Após o polimento, o Charisma com polimerização adicional pelo calor foi estatisticamente superior aos demais / Abstract: The purpose of this study was to investigate the influence of mechanic brushing on hardness Knoop and surface roughness of Charisma and Artglass utilizing different curing. Twenty samples with 8mm diameter were made in a 2.0mm thick teflon plate, and Charisma was light cured from the top for 40 seconds. Ten were addtionally heat cured in water for 5 minutes at 1000 C. Ten samples of the Charisma and ten of the Artglass were cured in an Uni-XS oven for 180 seconds. Five samples of each material received finishing and polishing treatment and five (control) without treatment. Knoop hardness were measured using HMV 2000 SHIMADZU, with a charge of 50 9 by 30 seconds. Five indentetion were made of each samples. Roughness was verified using Prazis-Rug. After the specimens were submited to 30,000 cycling in a brushing machine Equilabor. Afierwards, the hardness knoop and roughness were verified again. The results were statistically analysed using a Tukey's Test (5%). The r:esults indicated that (1 )-The roughness for Charisma light cured (O. 146/lm) was higher than Charisma light and heat curing (0.132/lm), Charisma cured in an Uni-XS oven (0.088/lm) and Artglass (0.096/lm) before brushing without polishing, while the Artglass was more roughness afier brushing (p<0.05); (2)-The roughness afier polishing (before and afier brushing) the Artglass (0.358/lm) was significantly stronger than Charisma cured in an Uni-XS oven (0.214/lm); (3) -The hardness Knoop for Charisma cured in an Uni-XS (48.84) and Artglass (42.53) without polishing before brushing were significantly stronger than Charisma light cured (34.78) and heat curing (29.04). Afier polishing and brushing Charisma cured in an Uni-XS (54.70) and Charisma light and heat curing I (53,24) were significantly stronger than Artglass (45.49) and Charisma light cured I (34.46); (4)-After brushing, Charisma heat curing, Artglass and Charisma cured in . na Uni-XS were statisticaly stronger than Charisma light cured (p<O.05), without polishing. After polishing, Charisma heat curing was statisticaly stronger than ali / Mestrado / Mestre em Materiais Dentários
17

Influencia do substrato dentinario e do material restaurador na infiltração marginal de restaurações cervicais

Saito, Solange Katia 08 January 2001 (has links)
Orientador : Jose Roberto Lovadino / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T23:46:19Z (GMT). No. of bitstreams: 1 Saito_SolangeKatia_D.pdf: 2022044 bytes, checksum: 1448f462721703745289700cf45f625b (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar, quantitativamente, a infiltração marginal de diferentes sistemas restauradores, quando colocados em substrato dentinário normal ou hipermineralizado artificialmente. Cento e oito cavidades foram confeccionadas em raízes de dentes bovinos e divididas em dois grupos experimentais (normal ou hipermineralizado), sendo subdivididas em quatro grupos, conforme o sistema restaurador utilizado: Vidrion R caps, Vitremer, Single Bond/Filtek Z250 e Clearfil SE Bond/Filtek Z250. A dentina foi hipermineralizada nas soluções: 1,5M de cálcio (CaCl2H2O, pH 5,7) por 1 hora e 1,5M de fosfato (K2HPO4, pH 9,5) por mais 1 hora, sendo, estocados em saliva artificial {1,5mM de cálcio (CaCl2H2O)+ 0,9mM de fosfato (K2HPO4)+ 0,15M de KCI; pH 7,0} por 24 horas, após a realização dos preparos cavitários. Os sistemas restauradores foram colocados em dentina hipermineralizada (Grupos I, ID, V e VII) e dentina normal (Grupos II, IV, VI e VllI). Os dentes restaurados foram submetidos a 1000 ciclos térmicos, entre temperaturas de 5 e 55±2°C. Em seguida, foram imersos em solução de azul de metileno a 2% por 24 horas. As amostras foram trituradas e o pó diluído em 4 ml de álcool absoluto. A infiltração marginal foi determinada e expressa em concentração de corante (ml). Os dados analisados pelos testes de Kruskal-Wallis e Ryan mostraram que não houve diferença estatística entre substrato; no entanto, houve diferença significante entre os materiais (p<0,01). Os resultados obtidos foram (mg/mI): GI-55,9a; GII-64,3a; GIII-12,lb; GIV-2I,2b; GV-32,9bc; GVI 30,lbc; GVll-41,9cd; GVIII-37,7cd. A microinfiltração relacionada com Vidrion R caps foi maior quando comparada com a dos outros materiais. As cavidades restauradas com Vitremer apresentaram valores de infiltração marginal semelhante ao sistema Single Bond/Filtek Z250 e este não diferiu do sistema Clearfil SE Bond/Filtek Z250 / Abstract: The aim of this study was to evaluate, quantitatively, the marginal leakage around different esthetic materials placed on normal and artificially hypermineralized cervical dentin cavities. One hundred eight cavities were prepared in bovine teeth roots and divided in two experimental groups (normal or hypermineralized), then subdivided in four subgroups according to the restorative system: Vidrion R caps, Vitremer, Single Bond/Filtek Z250 and Clearfil SE Bond/Filtek Z250. Dentin was hypermineralizing into the solutions contained: 1,5M calcium (CaCl2H20, pH 5,7) for 1 hour and 1,5M phosphate (K2HPO4, pH 9,5) for more 1 hour and then, stored in synthetic saliva {1,5mM calcium (CaCl2 H2O)+ 0,9mM phosphate (K2HPO4)+ 0,15M KCI; pH 7,0} for 24 hour, after cavities preparation. The restorative materials were placed in hipermineralized dentin (Groups 1, m, V and Vll) and normal dentin (Groups lI, IV, VI and VID). The restored teeth were submitted to 1000 thermal cycles between 5±2 °C and 55±:2 °C, then imersed in to 2% methylene blue solution for 24 hours. The samples were triturated and the powder were placed into absolute alcohol to dye extraction. The marginal leakage was determined and expressed by dye concentration (mm/ml). Data were analysed by the Kruskal-Wallis and Ryan test. The results were (mm/ml): GI- 55,9a; G-II 64,3a; G-III 12,lb; G-IV 21,2b; G-V 32,9bc; G-VI 30,lbc; G-VII 41,900; G-VIII 37,7cd. There was no statistically significant difference between the evaluated substrates; however, there was significant difference among materials (p<0,01). Microleakage related to Vidrion R caps material was greater than that any other material. Vitremer material presented the same marginalleakage values as Single BondIFiltek Z250. The latter didn't differ from Clearfil SE Bond system / Doutorado / Dentística / Doutor em Clínica Odontológica
18

Avaliação da dureza Knoop e do grau de conversão de resinas compostas em função de diversas espessuras

Carvalho, Christiane Martins de Lanna Salles 04 December 2002 (has links)
Orientador : Mario Fernando de Goes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-01T14:47:52Z (GMT). No. of bitstreams: 1 Carvalho_ChristianeMartinsdeLannaSalles_D.pdf: 2257438 bytes, checksum: 712de79b13bc866833446e328b010b18 (MD5) Previous issue date: 2002 / Resumo: A presença de moléculas não reagidas na base de restaurações feitas em resinas compostas fotoativadas, apresenta características indesejáveis no comportamento mecânico da restauração e na possível ocorrência de cárie secundária. O propósito do estudo foi avaliar o grau de polimerização de resinas compostas por meio mecânico (ensaio de Dureza Knoop) e físico (Espectroscopia de transmissão infravermelha de Fourier) . Foram utilizados os materiais Alert (Jeneric/Pentron), Fill Magic (Vigodent), Filtek Z250 (3M), P60(3M), Prodigy (Kerr), Solitaire (Kulzer), Sure Fill (Caulk/Dentsply) e Z100 (3M) Para o ensaio de dureza Knoop amostras cilíndricas (5mm X 5mm) foram polimerizadas em um único incremento usando o fotoativador XL 1000 ( 3M - 500mW/cm2 de intensidade luminosa - por 40 segundos) de acordo com as instruções do fabricante e armazenadas em ambiente escuro com umidade relativa de100% à 37°C por 24 horas. Em seguida, as amostras foram fixadas à bases de resina acrílica, seccionadas longitudinalmente, pOlidas sob refrigeração com papel de carboneto de silício nas granulações 400,600 e 1200 seguido de rodas de pano umedecidas com pasta diamantada de 6, 3 e 1 µm, com banhos em ultrassom entre cada procedimento. O ensaio de dureza Knoop foi aplicado com o auxílio de Microdurômetro Shimadzu HMV - 2000 ( carga de 25g e velocidade de penetração de 12 segundos) com 4 impressões nas profundidades de 1, 2, 3 e 4mm e em largura com distâncias de 1 mm entre elas totalizando 16 impressões por amostra. A análise química do grau de conversão, feita por espectroscopia de transmissão infravermelha de Fourier, utilizou amostras não polimerizadas e polimerizadas. Amostras de resina composta não polimerizada foram prensadas entre dois discos de vidro de Brometo de Potássio (KBr) para efetuar a análise. Para análise do material polimerizado, uma amostra cilíndrica com 5mm de espessura por 12 mm de diâmetro foi confeccionada para cada grupo. As amostras foram armazenadas em ambiente escuro a 37°C com umidade relativa por 24 horas. Assim, a amostra foi seccionada com espessura de 0,5 mm e triturada para obtenção de um pó, que foi misturado ao KBr e prensado sob carga de 10 tono para obtenção de um disco. Este disco com espessura em torno de 0,25 mm foi levado à análise química para obtenção de valores de grau de conversão. Os espectros obtidos foram levados ao cálculo da área abaixo dos picos coincidentes com bandas nas regiões referentes aos anéis aromáticos e alifáticos onde ocorreram conversões dos radicais livres. Estes valores, levados à fórmula matemática, forneceram valores de grau de conversão em porcentagem. Por comparação foi elaborada uma sequência decrescente de valores de grau de conversão entre os grupos estudados, a saber: Alert=Z100=Sure Fill>P60= Z250= Fill Magic> Solitaire = Prodigy. Os resultados de dureza Knoop (teste de Tukey, ao nível de significância 5%) mostraram que os valores de dureza do material Alert foram significativamente superiores aos valores encontrados nos demais materiais e que todas as resinas analisadas mantiveram estáveis os valores de dureza nas diversas espessuras analisadas. A observação dos resultados leva a concluir que há uma relação não proporcional entre os valores de dureza e grau de conversão / Abstract: The presence of unreacted molecules at the base of restorations made of light cured resins, presents undesirable features in the mechanical behavior of the restoration and on the occurrence of secondary caries. The purpose of this work was to evaluate the polymerization of resins that received changes in the organic and inorganic composition through microhardness Knoop and the Fourrier transmission infra-red essay(FTIR) before and after polimerization . The materials used were Alert (Jeneric/Pentron), Fill Magic (Vigdent), Filtek Z250(3M), P60(3M), Prodigy (Kerr), Solitaire (Kulzer), Sure Fill (Caulk/Dentsply) e Z100(3M). For the hardness essay, the samples were made using a matrix of 5mm x 5mm in only one increment, with the aid of a visible light curing unit model XL 1000 (3M - 500 mW) for 40 seconds in agreement with the manufacture's instructions and stored in the dark in relative humidity at 37°C for 24 hours. Then, the samples were fixed to acrylic resin bases with the aid of wax, longitudinally eroded up to the center area and polished under water. With 400, 600, 1200 silicon carbide paper followed by 6, 3 and 1 µm diamond paste and then cleaned ultrassonically between each procedure. The Knoop hardness test was applied with the Microhardness Shimadzu HMV - 2000 (load of 25g/12 seconds speed) with 4 indentations in the depths of 1, 2, 3 and 4mm with distances of 1 mm between them. The FTIR essay was performed using a film of the material obtained by pressing it between two KBr (Potassium bromet) glasses and taken to the FTIR analysis in Nicolet (52 DX FT-IR spectrometer 400-4000 cm -1). For the cured material essay, a cilindric sample was made (5mm thickness X 12 mm diameter) for each group, cured with the aid ofaXL 100 machine ( 3M - 500mW) according to the manufacturer instructions. The samples were stored in rei ative humidity in total darkness in 37 °C for 24 hours. Then, the surface that received the light application was seccionated with the aid of a diamond disc under irrigation to a thickness of O,5mm. The sample was powdered into a very fine powder, mixed to KBr and pressed under 10 ton. to get a disc, taken to the FTIR analysis This disc with 0,25 mm thickness was taken to the chemistry analysis to obtain cure degree values. The spectra obtained were taken to the area calculation of the aromatic and alifatic rings where monomer convertion occurred. These values, taken to a mathematic formulation, give cure degree values in percentage. In the statistic analysis ( Turkey test) of the results related with depth, the Z100 material showed difference statistically significant under 1 mm when compared with the others levels of depth, Whereas the others materials showed hardness values statistically similar in the various depths. As to the hardness values among the different materials, both the 3M products ( P 60 and Filtek Z250) didn't show statistic difference between them but they were different from the others materiais, wich were statistically different between them. The decreasing hardness order is Alert=Z100=Sure Fill>P60= Z250= Fill Magic> Solitaire = Prodigy. The results analysis reach the conclusion that there is a maintenance of the hardness values on the various depths of the materials analyzed. The correlation between hardness and cure degree is positive for all the materials studied. / Doutorado / Doutor em Materiais Dentários
19

Influencia da escovação sobre a dureza knoop e rugosidade de superficie de materiais restauradores esteticos

Carvalho, Adriana Silva de 10 December 1998 (has links)
Orientadores: Lourenço Correr Sobrinho, Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-24T11:42:24Z (GMT). No. of bitstreams: 1 Carvalho_AdrianaSilvade_D.pdf: 3871249 bytes, checksum: 32288d9fbf44f80ddebb2d160bd766b8 (MD5) Previous issue date: 1998 / Resumo: O propósito deste estudo foi avaliar a influência da escovação mecânica sobre a dureza Knoop e rugosidade de superfície antes e após a escovação, dos materiais restauradores estéticos, conhecidos comercialmente como: SR-Isosit, Artglass e Porcelana Duceram, submetidos ou não ao polimento. Oito corpos-de-prova com formato cônico (7 mm de diâmetro na região de superfície e 6 mm de diâmetro na superfície oposta por 2,5 mm de espessura) foram confeccionados para cada tipo de material, e armazenados em temperatura e umidade ambiente (23 '+ OU ¿' 1 °C, 50% '+ OU ¿' 5 U.R.) por 24 horas. Após esse período, quatro corpos-de-prova receberam tratamento de acabamento e polimento, e quatro não (controle). Em seguida, os corpos-de prova foram levados ao rugosímetro (Prazis - Rug 03 - Argentina), para determinarmos a rugosidade inicial da superfície. Foram feitas três leituras em cada corpo-de-prova, totalizando 72 leituras. Após a verificação da rugosidade inicial, os corpos-de-prova foram submetidos ao ensaio de dureza Knoop inicial no aparelho HMV - 2000 (Shimadzu), calibrado com carga de 50 gramas, atuando por 30 segundos. Foram efetuadas 3 leituras em cada corpo de-prova. Posteriormente, os corpos-de-prova foram levados a uma máquina de escovação Equilabor, submetidos à movimentos lineares de escovação com escovas dentais Oral-B 30 e creme dental Sorriso (Kolynos do Brasil), totalizando 30.000 ciclos de escovação. Em seguida, foram novamente submetidos à leitura da rugosidade superficial produzida pela escovação e ao teste de dureza Knoop. Os resultados foram submetidos à análise de variância e ao teste de Tukey. O SR-Isosit apresentou valores de rugosidade superiores em relação aos ART e DUG (p<0,05), antes da escovação e sem polimento; enquanto o ART foi o mais rugoso após a escovação. O polimento proporcionou aumento na rugosidade superficial dos 3 materiais, antes a após a escovação, sendo que o Duceram (DUG) apresentou maior rugosidade. De uma maneira geral, os valores de rugosidade foram maiores quando o polimento foi feito antes da escovação, e após a escovação nos corpos-de prova não polidos. A porcelana DUC com e sem polimento antes da escovação apresentou os maiores valores de dureza Knoop em relação ao SRI e ART, os quais não diferiram entre si (p>O,05). Resultados semelhantes foram obtidos após a escovação. A porcelana (DUC) com polimento antes da escovação apresentou valores estatisticamente superiores (p<O,05) em relação aos valores obtidos após a escovação. Nenhuma diferença estatística (p>O,05) foi observada para os materiais SRI e ART. Para as amostras não submetidas ao polimento, nenhuma diferença (p>O,05) foi encontrada entre os tratamentos antes e após a escovação. Independente do material restaurador, o polimento proporcionou valores de dureza Knoop estatisticamente superiores para os três materiais antes e após a escovação / Abstract: The purpose of this study was to investigate the influence of mechanic brushing on Knoop hardness and surface roughness of SR-Isosit, Artglass and Duceram. Eight specimens with 7mm in diameter and 2.Smm thickness were prepared for each material and stored in a controlled environment (23 '+ OU ¿' 1°C; 50 '+ OU ¿' RH). Four specimens of each material received fíníshing and polishing treatment and four without treatment (control). For each samples the roughness and Knoop hardness were verified, using Prazis-Rug 03 - Argentina and HMV - 2000 ~himadzu (50 g, during 30 s each tests) apparatus respectively. Afier the specimens were submited to 30,000 cycling in a Equilabor brushing machine, using a toothbrush (Oral-B 30) and toothpast (Kolynos). Afierwards, the Knoop hardness and roughness were verified. The results were statistically analysed using a Tukey's test. The results indicated that (1) ¿ The roughness for SR-Isosit was significantly higher than Artglass and Duceram (p<0,05) before tooth brushing without polishing, while the Artglass was more roughness afier toothbrushing; (2) - The roughness afier polishing of each material before or afier toothbrushing were significantly higher than without polishing (control) (p<0,05); (3) - The Knoop hardness for Duceram with and wíthout políshing before or afier toothbrushing was significantly stronger than SR-Isosit and Artglass (p<0,05). No difference was found between SR-Isosit and Artglass / Doutorado / Materiais Dentarios / Doutor em Ciências
20

Grau de conversão e nanodureza de um cimento resinoso dual fotoativado através de diferentes espessuras de uma resina nanocerâmica CAD/CAM

Chraim, Gustavo Georges de Mattos January 2016 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T04:26:14Z (GMT). No. of bitstreams: 1 341092.pdf: 7453597 bytes, checksum: 8acacedccc72534f3475caa2270543b6 (MD5) Previous issue date: 2016 / Este estudo avaliou o grau de conversão (DC) pela técnica FTIR-ATR e a nanodureza pela técnica de Oliver e Phar de um cimento resinoso de cura dual (RelyX Ultimate, 3M ESPE) fotoativado através de diferentes espessuras da resina nanocerâmica (NCR) LAVA Ultimate (3M ESPE) (0mm, 1mm, 2mm e 5mm), com diferentes tempos de fotoativação (20s e 40s) à uma irradiação constante de 1100mW/cm², imediatamente após a fotoativação e após 24 horas. Os dados coletados foram analisados por uma análise de variância de 3 fatores para medidas repetidas e os efeitos das interações foram analisados pelo teste de Sidak. Para o DC, os resultados mostraram que todos os fatores influenciam significativamente (p<0,001), sendo os maiores graus de conversão são obtidos após 24 horas (p<0,001), com a menor espessura de NCR (p<0,001) e fotoativação por 40s (p<0,001). Também ficou constatada a interação dupla entre todos estes fatores (p<0,001), mas o resultado da interação tripla foi não significativo (p=0,104). Quanto à nanodureza, todos os fatores estudados influenciaram a nanodureza (p<0,001), assim como a interação dupla entre eles (p<0,001) e a interação tripla entre os fatores (p<0,001).<br> / Abstract : This study evaluated the degree of conversion (DC) by FTIR-ATR technique and nanohardness by Oliver and Phar technique of a dual cured resin cement (RelyX Ultimate, 3M ESPE) photoactivated through different thicknesses of nanoceramic resin (NCR) LAVA Ultimate (3M ESPE) (0 mm, 1 mm, 2 mm and 5 mm) with different curing times (20s and 40s) at a constant irradiation 1100mW / cm², immediately after curing and after 24 hours. The collected data was analyzed by 3-way ANOVA repeated measures and the effects of the interactions were analyzed by Sidak test. DC results were significant to all factors (p <0.001), and the highest degrees of conversion are obtained after 24 hours (p <0.001), low thickness NCR (p <0.001) and 40 seconds light cure (p <0.001). It was also found double interaction between all of these factors (p <0.001), but the result of the triple interaction was not significant (p = 0.104). Nanohardness was influenced by all these factors (p <0.001), as well as double interaction between them (p <0.001) and triple interaction between factors (p <0.001).

Page generated in 0.118 seconds