• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 108
  • 3
  • Tagged with
  • 111
  • 111
  • 73
  • 72
  • 41
  • 26
  • 19
  • 19
  • 16
  • 15
  • 14
  • 14
  • 14
  • 13
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Anisotropia fracionada na substância negra não é um biomarcador diagnóstico para doença de Parkinson / Substantia nigra fractional anisotropy is not a diagnostic biomarker of Parkinson\'s disease

Hirata, Fabiana de Campos Cordeiro 25 October 2018 (has links)
Estudos recentes têm sugerido que as imagens de tensor de difusão podem ser úteis para diagnosticar doença de Parkinson (DP). Nosso objetivo foi estimar a exatidão diagnóstica da anisotropia fracionada da substância negra (FA-SN) para o diagnóstico de DP, em uma amostra mais próxima do cenário clínico, incluindo pacientes com tremor essencial (TE) e voluntários sadios (VS). Para uma compreensão mais profunda de nossos achados, também realizamos uma revisão sistemática da literatura e meta-análise para estimar a mudança média da FA-SN induzida pela DP e a precisão diagnóstica dessa medida. Nossa amostra consistiu de 135 pacientes: 72 pacientes com DP, 21 com TE e 42 VS. Dois exames em RM 3T foram realizados em diferentes locais. Em nossa amostra, não encontramos diferenças significativas entre os grupos e a FA-SN não foi útil para o diagnóstico. O maior componente da variabilidade foi a interação sítio-sujeito. Os resultados desta amostra foram fundidos em uma meta-análise que incluiu 1549 indivíduos compostos de 896 pacientes com DP e 653 VS. Utilizaram-se os modelos bivariados e inversos de variância inversa para resumir as medidas de acurácia diagnóstica e as diferenças de médias, respectivamente. A meta-análise estimou uma pequena diminuição nos valores médios da FA-SN na DP (0,03 menor nos pacientes com DP (IC: 0,01 - 0,06)). Apesar disso, sua capacidade discriminatória para o diagnóstico da DP foi baixa. A sensibilidade e a especificidade combinadas foram, respectivamente, 70% (IC: 65 - 74) e 63% (IC: 57 - 69). Houve alta heterogeneidade entre os resultados dos estudos (I2 = 92%). O estudo de caso-controle e a meta-análise das medidas de anisotropia fracionada na substância negra de pacientes com doença de Parkinson e voluntários sadios demonstram que o seu uso como biomarcador de DP não é confiável / Recent studies have suggested that diffusion tensor images can be useful to diagnose Parkinson\'s disease (PD). Our goal was to estimate the diagnostic accuracy of substantia nigra fractional anisotropy (SN-FA) for PD diagnosis in a sample closer to the clinical setting, including patients with essential tremor (ET) and healthy controls (HC). To a deeper understanding of our findings, we also performed a systematic literature review and meta-analysis to estimate mean change of SN-FA induced by PD, and diagnostic accuracy of this measurement. Our sample consisted of 135 subjects: 72 PD and 21 ET patients and 42 HC. Two 3T MRI scans were performed in different sites. In our sample, we did not find significant mean difference between groups and SN-FA was useless for diagnosis. The largest component of explained variability of SN-FA was site-subject interaction. MRI results of this sample were merged in a meta-analysis that included 1549 subjects composed of 896 PD patients and 653 HC. The normal bivariate and the inverse-variance random-effect models were used to summarize diagnostic accuracy measures and mean differences respectively. Meta-analysis estimated a small decrease in mean SN-FA values in PD (0.03 lower in PD patients (CI: 0.01 - 0.06)). Despite this fact, its discriminatory capability to diagnose PD was low. The pooled sensitivity and specificity was respectively 70% (CI: 65 - 74) and 63% (CI: 57 - 69). There was high heterogeneity between studies results (I2 = 92 %). This case-control study and meta-analysis of substantia nigra fractional anisotropy measurements in Parkinson\'s disease and healthy volunteers demonstrate that their use as a PD biomarker is not reliable
92

Acurácia diagnóstica da ecocardiografia sob estresse associada ao estudo da perfusão miocárdica com contraste na avaliação da isquemia miocárdica: estudo comparativo entre adenosina e dobutamina / Diagnostic accuracy of quantitative real time myocardial contrast echocardiography for the detection of myocardial ischemia. A comparative study between adenosine and dobutamine

Kowatsch, Ingrid 23 August 2005 (has links)
A ecocardiografia com perfusão miocárdica em tempo real (EPMTR) permite a quantificação do fluxo sangüíneo miocárdico e, quando realizada durante o estresse, da reserva de fluxo miocárdico (reserva Axß). Essa técnica tem potencial para ser uma importante ferramenta para o diagnóstico não-invasivo da doença arterial coronariana (DAC). Apesar do conhecimento atual das alterações fisiológicas que ocorrem com o uso de agentes vasodilatadores ou catecolaminas na circulação coronariana, não há dados na literatura comparando diretamente o valor da EPMTR, sob estresse pela dobutamina e pela adenosina, para a detecção de DAC em humanos. Os objetivos deste estudo foram: avaliar, em um mesmo grupo de pacientes, a exeqüibilidade e a acurácia da EPMTR, sob estresse pela dobutamina e pela adenosina, para a detecção de estenose arterial coronariana angiograficamente significativa e determinar o valor adicional da análise quantitativa da perfusão miocárdica sobre o eletrocardiograma de 12 derivações, da motilidade segmentar e da análise qualitativa da perfusão miocárdica obtidas durante o estresse pela dobutamina e pela adenosina. Estudamos 54 pacientes (média etária de 60±9 anos, 33 homens) com suspeita clínica de DAC e indicação de angiografia coronariana. Todos os pacientes foram submetidos à EPMTR sob estresse pela adenosina na dose de 140 g/kg/min por seis minutos e, após um intervalo de três a cinco horas, à EPMTR sob estresse pela dobutamina-atropina. O contraste ecocardiográfico utilizado foi o PESDA (Perfluorocarbon-Exposed Sonicated Dextrose and Albumin), administrado por via intravenosa periférica de forma contínua. Para ambas as EPMTR sob estresse pela dobutamina e pela adenosina, foram feitas análises do eletrocardiograma em 12 derivações (ECG), da motilidade segmentar e análise qualitativa e quantitativa da perfusão miocárdica. A quantificação da velocidade do fluxo miocárdico (ß) e do fluxo sangüíneo miocárdico (Axß) foi realizada por meio da utilização do programa computacional QLab 3.0 (Philips Medical Systems, Bothell, WA, USA). Todos os pacientes foram submetidos à angiografia coronariana quantitativa (ACQ) em um intervalo de até 30 dias da EPMTR. Foi considerada DAC a presença de lesão coronariana > 50% do diâmetro luminal. Dos 54 pacientes estudados, 25 (46%) apresentaram lesão coronariana >50% e 29 (54%) não apresentaram lesão coronariana significativa. A exeqüibilidade da quantificação da reserva Axß foi semelhante para a EPMTR sob estresse pela adenosina e pela dobutamina (91% versus 90% dos territórios arteriais; p = ns). A variabilidade da quantificação interobservador para os parâmetros de reserva ß e Axß foi de 6,8% (r = 0,98) e 5,5% (r = 0,97), respectivamente. A variabilidade intra-observador para os mesmos parâmetros foi de 2,1 % (r = 0,99) e 7,4 % (r = 0,95), respectivamente. A análise quantitativa da perfusão miocárdica, obtida pela EPMTR sob estresse pela dobutamina, apresentou sensibilidade de 84%, especificidade de 76% e acurácia de 80% para a detecção de DAC, enquanto que a EPMTR sob estresse pela adenosina apresentou sensibilidade de 88%, especificidade de 72% e acurácia de 80%. O valor incremental das modalidades estudadas para o diagnóstico de DAC foi analisado em modelo que incluiu o ECG, ECG e motilidade segmentar, ECG e motilidade segmentar e perfusão qualitativa e, por último, ECG e motilidade segmentar e perfusão qualitativa e quantitava, tanto para a EPMTR sob estresse pela dobutamina como pela adenosina (2 de 4,9 versus 20,1 versus 23,7 versus 38,4) e (2 de 9,9 versus 20,1 versus 26,7 versus 59,4), respectivamente. Concluímos que a avaliação quantitativa da EPMTR apresenta boa exeqüibilidade. A EPMTR sob estresse pela dobutamina e a pela adenosina apresentam acurácias diagnósticas similares para a detecção de lesão angiograficamente significativa. A análise quantitativa da perfusão miocárdica apresenta valor diagnóstico adicional aos outros parâmetros obtidos durante o estresse pela dobutamina e adenosina. / Real time myocardial contrast echocardiography (RTMCE) has allowed for the quantification of myocardial blood flow reserve (MBFR). This technique is a valuable tool for the noninvasive detection of coronary artery disease (CAD). Both adenosine and dobutamine are currently used stressor agents during RTMCE. Although it has already been shown the effects of these drugs on the coronary physiology, no study has directly compared both agents during RTMCE. The aims of this study were to determine the feasibility and diagnostic accuracy of adenosine versus dobutamine stress RTMCE for the detection of angiographically significant CAD. In addition, we sought to determine the additional value of quantitative RTMCE over the electrocardiogram, wall motion, and qualitative analysis of myocardial perfusion. The study involved 54 patients (60±9 years, 33 men) with suspected CAD. Patients underwent RTMCE at rest and during continuous infusion of 140g/kg/min of adenosine for six minutes, and dobutamine stress. The contrast agent used in the study was PESDA (Perfluorocarbon-Exposed Sonicated Dextrose and Albumin) administered in continuous intravenous infusion. Quantification of plateau of acoustic intensity (A) and microbubble velocity () was performed off line using a specific software (QLab 3.0, Philips Medical Systems, Bothell, WA, USA). Myocardial blood flow was determined as Ax. Quantitative coronary angiography was performed in all patients within 30 days of RTMCE, and CAD was defined as >50% luminal diameter coronary stenosis. There were 25 (46%) patients with CAD and 29 (54%) patients without obstructive lesion. The feasibility of quantitative MBFR was the same for adenosine and dobutamine stress RTMCE (91% versus 90% in all arterial territories; p=ns). The intraobserver variabilities for the measurements of ß and Axß reserve were 2.1% (r = 0.99) and 7.4% (r = 0.95), respectively. The interobserver variabilities for the same parameters were 6.8% (r = 0.98) and 5.5% (r = 0.97), respectively. The sensitivity, specificity and diagnostic accuracy of ß reserve obtained during dobutamine stress RTMCE for detecting CAD were 84%, 76%, and 80%, respectively, and during adenosine stress RTMCE they were 88%, 72% and 80%. The incremental value for the diagnosis of CAD was analyzed in a model that included the EKG, EKG and wall motion, EKG and wall motion and qualitative perfusion analysis and finally, EKG and wall motion and qualitative and quantitative perfusion analysis, for dobutamine and adenosine RTMCE (2= 4,9 versus 20,1 versus 23,7 versus s 38,4) and (2= 9,9 versus 20,1 versus 26,7 versus 59,4), respectively. In conclusion, quantitative RTMCE is a feasible technique in patients with suspected CAD. Dobutamine and adenosine stress RTMCE had similar diagnostic accuracy for the detection of angiographically significant lesion. Quantitative analysis of myocardial perfusion had incremental diagnostic value over the other parameters obtained during both dobutamine and adenosine stress RTMCE.
93

Validação de sistema portátil de monitorização respiratória para o diagnóstico de apneia obstrutiva do sono em pacientes com doença arterial coronariana / Validation of portable respiratory monitoring system for the diagnosis of obstructive sleep apnea in patients with coronary artery disease

Soares, Naury de Jesus Danzi 22 February 2011 (has links)
Introdução: A apneia obstrutiva do sono (AOS) é caracterizada por episódios repetidos de colapso parcial ou completo das vias aéreas superiores durante o sono, resultando em eventos respiratórios caracterizados por hipopneias ou apneias, respectivamente. Os eventos respiratórios podem resultar em fragmentação do sono, hipoxemia recorrente e geração de pressão intratorácica negativa. Todos esses mecanismos são potencialmente deletérios ao sistema cardiovascular. A AOS é comum entre pacientes com doença cardiovascular, porém ainda é pouco reconhecida. O padrão ouro para o diagnóstico da AOS é a Polissonografia (PSG) completa. O acesso a PSG completa é limitado, contribuindo para o subdiagnóstico da AOS. A poligrafia noturna de variáveis respiratórias (PGR) é um método simplificado, sendo uma alternativa promissora para o diagnóstico da AOS. No entanto, estudos de validação de PGR incluíram somente populações pré-selecionadas ou referidas para laboratórios de sono e excluíram pacientes com comorbidades significativas. Atualmente a Academia Americana de Medicina do sono reconhece o uso da PGR para o diagnóstico da AOS em pacientes com alta probabilidade pré-teste de AOS moderada a grave e em pacientes sem comorbidades significativas. Objetivo: Validar a PGR para o diagnóstico de AOS entre pacientes consecutivos avaliados para cirurgia de revascularização miocárdica, portanto, com Doença Arterial Coronariana (DAC). Avaliar a prevalência da AOS e a utilidade dos sintomas clínicos para o diagnóstico da AOS entre os pacientes com DAC. Métodos: Pacientes com indicação de revascularização do miocárdio foram avaliados através de exames clínicos e laboratoriais de rotina, escala de sonolência diurna (Epworth) e risco clínico de apneia do sono (questionário de Berlin), ecocardiograma, PSG e PGR. A PGR utilizada é classificada como tipo 3, com os seguintes canais: fluxo de ar, esforço respiratório, oximetria de pulso, frequência de pulso, ronco e sensor de posição, (Stardust II ®). Resultados: Foram estudados 70 pacientes consecutivos (76% do sexo masculino); idade (média DP) = 58 ± 7 anos, índice de massa corpórea (IMC) [mediana (25-75%)] = 27,6 (25,8-31,1) kg/m2. Vinte pacientes (29%) apresentaram fração de ejeção do ventrículo esquerdo (FEVE) 45%. A PSG da população revelou índice de apneia e hipopneia (IAH)= 2320 eventos/h. A prevalência de AOS com um IAH 5, 15 e 30 eventos/h foi de 87%, 54% e 27%, respectivamente. A sonolência diurna medida pela escala de Epworth e o risco clínico de AOS verificado pelo questionário de Berlin foram pobres preditores de AOS. A sensibilidade / especificidade da PGR para detectar AOS (IAH 5 eventos/h) e AOS grave (IAH 30 eventos/h) foram 0,92/0,67% e 0,42/0,92%, respectivamente. A média da diferença do IAH entre os dois métodos diagnósticos apresentada no Bland-Altman foi de + 5,3, indicando que os valores do IAH da PGR foram em média inferiores aos da PSG. O desvio padrão da diferença foi de 14,6 eventos/hora, apresentando uma considerável concordância entre o IAH da PSG e da PGR. Conclusão: Este estudo valida o uso da PGR para o diagnóstico da AOS em uma população de pacientes consecutivos, avaliados para revascularização do miocárdio, em quem a doença cardíaca é significativa. A prevalência de AOS entre pacientes com DAC é alta atingindo mais de 50% dessa população. No entanto, os sintomas clínicos, nessa população, não são preditores adequados de AOS. Em função da alta prevalência de AOS e baixa especificidade de sintomas clínicos, nossos dados sugerem que a PGR é um instrumento promissor para a avaliação de pacientes com DAC avaliados para cirurgia de revascularização do micárdio / Introduction: Obstructive sleep apnea (OSA) is characterized by repeated episodes of partial or complete collapse of the upper airway during sleep, resulting in respiratory events characterized by hypopnea or apnea, respectively. Respiratory events may result in sleep fragmentation, hypoxemia and recurrent generation of negative intrathoracic pressure. All these mechanisms are potentially harmful to the cardiovascular system. OSA is common among patients with cardiovascular disease, but is still poorly recognized. The gold standard for diagnosis of OSA is polysomnography (PSG). Access to full PSG is limited, contributing to the under diagnosis of OSA. The polygraph nocturnal of respiratory variables (PGR) is a simplified method, being a promising alternative for the diagnosis of OSA. However, validation studies of PGR only included populations pre-selected or referred to sleep laboratories and excluded patients with significant comorbidities. Currently the American Academy of Sleep Medicine recognizes the use of PGR for the diagnosis of OSA in patients with high pretest probability of moderate to severe OSA and in patients without significant comorbidities. Objective: Validate the PGR for the diagnosis of OSA among consecutive patients evaluated for coronary artery bypass grafting (CABG), therefore with Coronary Artery Disease (CAD). To assess the prevalence of OSA and to evaluate the usefulness of clinical symptoms for diagnosis of OSA among patients with CAD. Methods: Patients with indication of CABG were evaluated by clinical examination and routine laboratory, the scale of daytime sleepiness (Epworth) and clinical risk of sleep apnea (Berlin questionnaire), echocardiogram, PSG and PGR. The PGR use is classified as type 3, with the following channels: airflow, respiratory effort, pulse oximetry, pulse rate, snoring and position sensor, (Stardust II ®). Results: We studied 70 consecutive patients (76% male); age (mean SD) = 58 ± 7 years; body mass index (BMI), [median (25-75%)] = 27,6 (25,8 to 31,1) kg/m2. Twenty patients (29%) had left ventricular ejection fraction (LVEF) 45%. The PSG of population showed apnea-hypopnea index (AHI) = 23 20 events / h. The prevalence of OSA with an AHI 5, 15 and 30 events / h was 87%, 54% and 27%, respectively. Daytime sleepiness measured by Epworth Sleepiness Scale and the clinical risk of OSA verified by the Berlin questionnaire were poor predictors of OSA. The sensitivity and specificity to detect OSA (AHI 5 events / h) and severe OSA (AHI 30 / events) of the PGR were 0,92/0,67% and 0,42/0,92%, respectively. The average difference in AHI between the two diagnostic methods presented in Bland-Altman was + 5,3, indicating that the values of the AHI of the PGR were on average lower than the PSG. The standard deviation of the difference was 14,6 events / hour, presenting a considerable agreement between the AHI of PSG and the PGR. Conclusion: This study validates the use of PGR for the diagnosis of OSA in a population of consecutive patients evaluated for CABG, in whom heart disease is significant. The prevalence of OSA among patients with CAD is high reaching over 50% of this population. However, the clinical symptoms are not adequate predictors of OSA in this population. Due to the high prevalence of OSA and low specificity of clinical symptoms, our data suggest that the PGR is a promising tool for the assessment of CAD patients evaluated for surgery for the CABG
94

Aplicabilidade da técnica de PCR em tempo real para caracterização de espécies de Leishmania / Aplicability of real time PCR technique for leishmania species characterization

Morais, Rayana Carla Silva de January 2015 (has links)
Submitted by Adagilson Silva (adagilson@cpqam.fiocruz.br) on 2015-03-25T18:04:54Z No. of bitstreams: 1 2015morais-rcs.pdf: 1252683 bytes, checksum: 22ecfe946756c7d2dfa99794ad2d2d17 (MD5) / Approved for entry into archive by Adagilson Silva (adagilson@cpqam.fiocruz.br) on 2015-03-25T18:27:04Z (GMT) No. of bitstreams: 1 2015morais-rcs.pdf: 1252683 bytes, checksum: 22ecfe946756c7d2dfa99794ad2d2d17 (MD5) / Approved for entry into archive by Adagilson Silva (adagilson@cpqam.fiocruz.br) on 2016-02-19T13:29:39Z (GMT) No. of bitstreams: 1 2015morais-rcs.pdf: 1252683 bytes, checksum: 22ecfe946756c7d2dfa99794ad2d2d17 (MD5) / Made available in DSpace on 2016-02-19T13:29:39Z (GMT). No. of bitstreams: 1 2015morais-rcs.pdf: 1252683 bytes, checksum: 22ecfe946756c7d2dfa99794ad2d2d17 (MD5) / Fundação Oswaldo Cruz. Centro de Pesquisas Aggeu Magalhães / A Leishmaniose Tegumentar Americana (LTA) é causada por protozoários, do gênero Leishmania, envolvidos em um complexo ciclo biológico. No Brasil, sete espécies estão envolvidas com a etiologia da doença, distribuídas em todas as regiões geográficas e responsáveis por diferentes manifestações clínicas. Diante disso, o diagnóstico em conjunto com a identificação da espécie é de grande importância clínico-terapêutica. Este trabalho tem por objetivo avaliar a aplicabilidade da técnica de PCR quantitativa em tempo real (qPCR) para identificação de espécies de Leishmania envolvidas com a etiologia da LTA. Foram realizados ensaios de qPCR para padronização da Temperatura de melting (Tm) utilizando cepas de referência de diferentes espécies de Leishmania. Após o diagnóstico em amostras de sangue de animais domésticos utilizando a qPCR, as amostras positivas foram analisadas através de suas Tm, e os produtos de qPCR foram purificados e sequenciados. Dez amostras previamente caracterizadas por isoenzimas, também foram analisadas através da Tm. Ainda como teste de referência, foi padronizada uma Restriction Fragment Length Polymorphism (RFLP) utilizando as cepas de referência e testada nas amostras. Através da padronização da Tm das espécies, foram criados dois intervalos de análise: 1 (Tm = 78-79,99°C), que compreende: Leishmania (V.) braziliensis, Leishmania (V.) panamensis, Leishmania (V.) lainsoni, Leishmania (V.) guyanensis e Leishmania (V.) shawi; e 2 (Tm = 80-82,2°C), que compreende: Leishmania (V.) naiffi, Leishmania (L.) amazonensis e Leishmania (L.) mexicana. Um total de 223 amostras positivas foi analisado, destas, 58 incluídas no intervalo 1 e 165 no intervalo 2. O sequencimento de 94 destas amostras foi correspondente à L. (V.) braziliensis, L. (V.) panamensis e L. (V.) guyanensis. A RFLP em 173 amostras identificou 167 L. (V.) braziliensis, 05 L. (L.) mexicana e 01 L. (V.) panamensis. A análise da Tm das dez amostras caracterizadas por isoenzimas demonstrou 80 por cento de concordância (p = 0,6499) entre o padrão-ouro (isoenzimas) e os intervalos desenvolvidos neste estudo. Os resultados do sequenciamento foram concordantes com a qPCR em 43,62 por cento (n= 41) das amostras. A RFLP e qPCR tiveram 27,74 por cento (n= 48) de concordância. Análise estatística mostrou que a qPCR e sequenciamento são testes sem diferenças estatísticas significantes (p = 0,2566). Sendo assim, é possível concluir que a Tm da qPCR pode ser utilizada como um método para direcionamento da espécie de Leishmania presente na amostra em análise, sendo necessário a realização de métodos clássicos de caracterização, quando a precisão na identificação do parasito for crucial para implementação do tratamento, como em casos de resistência e/ou recidiva da doença. A utilização desta tecnologia pode ser ainda mais precisa quando for utilizada a metodologia com sondas desenhadas para cada espécie de Leishmania, sendo necessários estudos futuros para comprovar esta perspectiva (AU) / The American Cutaneous Leishmaniasis (ACL) is caused by protozoa of the genus Leishmania, involved in a complex biological cycle. In Brazil, seven species are involved in the etiology of the disease, distributed in all geographic regions and responsible for different clinical manifestations. Therefore, the diagnosis together with the identification of the species is of great clinical and therapeutic importance. This work aims to evaluate the applicability of the technique of real-time quantitative PCR (qPCR) for the identification of Leishmania species involved in the etiology of ACL. qPCR assays for standardizing the melting temperature (Tm) using reference strains of different species of Leishmania were performed. After the diagnosis on blood samples of domestic animals using the qPCR positive samples were analyzed by their Tm and qPCR products were purified and sequenced. Ten samples previously characterized by isoenzymes were also analyzed by Tm. Also as a reference test was standardized as Restriction Fragment Length Polymorphism (RFLP) using the reference strains and tested on samples. Through standardization of Tm species two ranges of analysis were created: 1 (Tm = 78-79,99°C), comprising: Leishmania (V.) braziliensis, Leishmania (V.) panamensis, Leishmania (V.) lainsoni, Leishmania (V.) guyanensis e Leishmania (V.) shawi; and, 2 (Tm = 80-82,2°C), comprising: Leishmania (V.) naiffi, Leishmania (L.) amazonensis e Leishmania (L.) mexicana. A total of 223 positive samples were analyzed, of these, 58 included in the range 1 and 165 in the range 2 to 94 and the sequence of these samples corresponded to L. (V.) braziliensis, L. (V.) panamensis and L. (V.) guyanensis. By RFLP in 173 samples were identified 167 L. (V.) braziliensis, 05 L. (L.) mexicana and 01 L. (V.) panamensis The analysis of Tm of the ten samples characterized by isoenzymes showed 80 per cent agreement (p = 0.6499) between the gold standard (isoenzymes) and intervals developed in this study. The sequencing results were concordant with qPCR in 43.62 per cent (n= 41) of the samples. The RFLP and qPCR had 27.74 per cent (n= 48) agreement. Statistical analysis showed that qPCR and sequencing tests are no statistically significant differences (p = 0.2566). Thus, we conclude that the Tm of qPCR can be used as a method for direction of Leishmania species present in the sample under analysis, performing classic methods of characterization is necessary when the accuracy in identifying the parasite is crucial for implementation treatment, such as in cases of resistance and / or recurrence of the disease. The use of this technology can be even more precise when the methodology with probes designed for every Leishmania species is used; future studies are needed to confirm this view (AU)
95

Caracterização do potencial diagnóstico de poliantígenos para detecção do Trypanosoma cruzi na fase crônica da doença de Chagas / Chracterization of the potencial diagnostic of polyantignes for detecting Trypanosoma cruzi in the chronic phase of Chagas disease

Santos, Fred Luciano Neves January 2016 (has links)
Made available in DSpace on 2016-06-17T14:14:16Z (GMT). No. of bitstreams: 2 license.txt: 1914 bytes, checksum: 7d48279ffeed55da8dfe2f8e81f3b81f (MD5) Tese_Fred_Luciano_Neves_Santos.pdf: 7174621 bytes, checksum: af4e9021f0c8974198df6ec268ccfaf9 (MD5) Previous issue date: 2016 / Made available in DSpace on 2016-07-05T22:07:11Z (GMT). No. of bitstreams: 3 Tese_Fred_Luciano_Neves_Santos.pdf.txt: 436440 bytes, checksum: 1d22503c32c1f332f780c4197a546123 (MD5) Tese_Fred_Luciano_Neves_Santos.pdf: 7174621 bytes, checksum: af4e9021f0c8974198df6ec268ccfaf9 (MD5) license.txt: 1914 bytes, checksum: 7d48279ffeed55da8dfe2f8e81f3b81f (MD5) Previous issue date: 2016 / Fundação Oswaldo Cruz. Centro de Pesquisas Aggeu Magalhães. Recife, PE, Brasil / O diagnóstico da doença de Chagas crônica (DCC) baseia-se em metodologias que usam em sua fase sólida antígenos brutos, semipurificados ou recombinantes, podendo resultar em baixa sensibilidade ou reação cruzada. Uma forma para resolver este problema é o uso de quimeras formadas por epítopos conservados e repetitivos de diferentes estruturas parasitárias em uma única molécula. O nosso objetivo foi caracterizar e avaliar o uso de quimeras em imunoensaios para o diagnóstico da DCC. As quimeras, IBMP-8.1, IBMP-8.2, IBMP-8.3 e IBMP-8.4 foram purificadas por meio de cromatografia e sua pureza avaliada por SDSPAGE. Ensaios de dicroísmo circular (DC) e espalhamento dinâmico da luz (EDL) foram usados para avaliação do raio hidrodinâmico das quimeras, avaliação de sua estabilidade e escolha do sistema tampão que oferecesse o menor estado de agregação molecular. Ensaios sorológicos para detecção de anticorpos anti-Trypanosoma cruzi através de ELISA foram realizados utilizando um painel de 857 amostras positivas para a DCC e 689 negativas. Para avaliação de reação cruzada foram usadas 1079 amostras de diversas doenças endêmicas no país. A purificação foi eficiente uma vez que o SDS-PAGE indicou ausência de degradação das quimeras. As análises de DC e EDL mostraram que as quatro quimeras apresentaram menor tendência de agregação em tampão carbonato pH 9,6, sendo, assim, este o sistema para a sensibilização das placas. Os ensaios sorológicos revelaram valores elevados de sensibilidade (Sen) e especificidade (Esp) para a molécula IBMP-8.4 (Sen-99,3%; Esp- 100%). O desempenho para as demais moléculas foi satisfatório, ficando os valores de Sen e Esp acima de 94%. As moléculas IBMP-8.1, IBMP-8.2, IBMP-8.3 e IBMP-8.4 apresentaram respectivamente 0,46%, 0,85%, 0,46% e 0,37% de reação cruzada. Os resultados apontam que as quimeras atingiram os critérios de proficiência do Ministério da Saúde podendo, dessa forma, ser utilizados em ensaios diagnósticos para a DCC. Chronic Chagas disease (CCD) diagnosis is based on serological methods employing crude, semipurified or recombinant antigens, which eventually may result in low sensitivity or crossreactivity. An alternative method for solving this problem is the use of chimeric molecules composed by conserved and repetitive epitopes of distinct parasite structures. Our objective was to evaluate the use of chimeras in immunoassays for the diagnosis of CCD. The chimeras IBMP-8.1, IBMP-8.2, IBMP-8.3 and IBMP-8.4 were purified by chromatography and their purity assessed by SDS-PAGE. Circular dichroism (CD) and dynamic light scattering (DLS) were used to assess the hydrodynamic radius of the chimeras, to evaluate their stability and to select the buffering system that offers the lowest state of molecular aggregation. Serological tests for detection of anti-Trypanosoma cruzi were performed by ELISA using a panel of 857 positive and 689 negative serum samples for CCD. Cross-reactivity was assessed by using 1079 serum samples from patients with unrelated diseases. The purification was efficient since SDS-PAGE indicated the absence of degradation of chimeric proteins. Analyses of CD and DLS showed that the four chimeras had low aggregation tendency in carbonate buffer, pH 9.6. Serological testing showed high values of sensitivity (Sen) and specificity (Spe) for IBMP-8.4 (Sen-99.3%; Spe-100%). The performance of other molecules was satisfactory, being the Sen and Spe values above 94%. Cross-reaction was observed in 0.46%, 0.85%, 0.46% and 0.37% of the samples tested against IBMP-8.1, IBMP-8.2, IBMP-8.3 and IBMP- 8.4, respectively. The results indicate that the chimeras reached the Brazilian Ministry of Health proficiency criteria and may thus be used in diagnostic assays for CCD.
96

Comparação de métodos de imagem do disco óptico e da camada de fibras nervosas da retina para o diagnóstico do glaucoma / Comparison of optic disc and retinal nerve fiber layer imaging methods for glaucoma diagnosis

Felipe de Araujo Andrade Medeiros 02 June 2005 (has links)
Alterações no aspecto do disco óptico e da camada de fibras nervosas da retina (CFN) freqüentemente precedem o aparecimento de defeitos de campo visual no glaucoma, o que faz com que a avaliação destas estruturas seja essencial para o diagnóstico precoce e prevenção da perda visual nesta doença. A polarimetria de varredura a laser (GDx VCC), a oftalmoscopia confocal de varredura a laser (HRT II [Heidelberg Retina Tomograph]) e a tomografia de coerência óptica (Stratus OCT) são tecnologias que permitem a avaliação objetiva e quantitativa do disco óptico e da CFN. No presente estudo, estas tecnologias foram comparadas em sua habilidade para diferenciar pacientes glaucomatosos de indivíduos normais. Pacientes com glaucoma foram selecionados com base na presença de defeitos reprodutíveis de campo visual na perimetria acromática automatizada (glaucoma perimétrico), ou com base na evidência documentada de progressão do dano glaucomatoso ao disco óptico, sem presença de defeitos de campo visual (glaucoma pré-perimétrico). Indivíduos normais apresentaram campos visuais e exame clínico dentro da normalidade. Todos os indivíduos foram submetidos a exames com o GDx VCC, HRT II, Stratus OCT e campo visual dentro de um período de três meses. Diversas medidas foram utilizadas para avaliação da acurácia diagnóstica, incluindo áreas sob as curvas receiver operating characteristic (AROC), sensibilidades para especificidades fixas, e razões de probabilidade. Modelos estatísticos foram utilizados para avaliação da influência da severidade do glaucoma e tamanho do disco óptico na performance diagnóstica dos diferentes instrumentos. Um olho de cada indivíduo foi utilizado para análise. Dos 258 sujeitos inicialmente avaliados, 33 (13%) foram posteriormente excluídos por apresentarem imagens de baixa qualidade em pelo menos um dos aparelhos, restando 225 indivíduos (133 glaucomatosos e 92 normais) para análise. Na comparação entre os parâmetros de cada instrumento com maiores valores de AROC, o parâmetro do GDx VCC, Nerve Fiber Indicator (NFI; AROC = 0,91), e o parâmetro do Stratus OCT, Espessura Média (AROC = 0,90), apresentaram áreas sob as curvas ROC significativamente superiores à do parâmetro do HRT II, função discriminante de Bathija (AROC = 0,84). A severidade do defeito de campo visual exerceu influência significativa sob a acurácia diagnóstica dos três instrumentos, com melhora no poder diagnóstico em casos mais avançados da doença. Para o GDx VCC e Stratus OCT, o aumento no tamanho do disco óptico foi associado à diminuição na sensibilidade para detecção do glaucoma; enquanto que, para o HRT II, diminuição no tamanho do disco óptico foi associada à diminuição na sensibilidade. Razões de probabilidade para resultados anormais nas xxv classificações finais de cada instrumento foram associadas a grandes efeitos de mudança na probabilidade pós-teste em relação à probabilidade préteste, sugerindo que o encontro de um resultado anormal em qualquer um destes testes, durante a avaliação de um paciente com suspeita de glaucoma, tem impacto significativo em aumentar a probabilidade de que a doença esteja presente. Além disso, os resultados obtidos na avaliação de pacientes com glaucoma pré-perimétrico sugerem que todos os três instrumentos sejam capazes de detectar alterações estruturais precoces no glaucoma, antes do aparecimento de defeitos de campo visual na perimetria acromática / Changes in the structural appearance of the optic nerve head (ONH) and retinal nerve fiber layer (RNFL) have been reported to precede the development of visual field loss in glaucoma. Detection of ONH and RNFL damage is therefore crucial for early diagnosis of glaucoma and prevention of functional loss from the disease. Scanning laser polarimetry (GDx VCC), confocal scanning laser ophthalmoscopy (HRT II [Heidelberg Retina Tomograph]) and optical coherence tomography (Stratus OCT) are different technologies capable of providing objective and quantitative information related to these structures. The purpose of the present study was to compare, in a single population, the diagnostic abilities of these technologies in the discrimination of glaucomatous patients from healthy subjects. Glaucoma patients were selected based on the presence of repeatable visual field defects, as identified by standard automated perimetry (perimetric glaucoma), or documented evidence of progressive damage to the optic disc, in the absence of detectable visual field loss (preperimetric glaucoma). Normal subjects had normal visual fields and normal clinical examination. All subjects underwent imaging with the GDx VCC, HRT II and Stratus OCT within a 3-month period. Several measures were used for evaluation of diagnostic accuracy, including the area under the receiver operating characteristic curve (AROC), sensitivities at fixed specifities, and likelihood ratios. Statistical models were used to evaluate the influence of glaucoma severity and optic disc size on the diagnostic performance of the different instruments. One eye of each individual was randomly selected for statistical analysis. From an initial group of 258 eligible subjects, 33 (13%) had images of unacceptable quality, leaving 133 glaucoma patients and 92 healthy subjects for further analysis. In the comparison of the parameters with highest values of AROC from each instrument, the GDx VCC Nerve Fiber Indicator (AROC = 0.91) and the Stratus OCT Average Thickness (AROC = 0.90) perfomed significanlty better than the HRT II Bathija discriminant function (AROC = 0.84). For all instruments, the diagnostic accuracy increased with increasing severity of visual field defects. For the GDx VCC and Stratus OCT parameters, an increase in the size of the optic disc was related to a decrease in the sensitivity for glaucoma detection. An opposite effect was observed with the HRT II: a decrease in the size of the optic disc was related to a decrease in the sensitivity for glaucoma diagnosis. Abnormal results for each of the instruments were associated with strong positive likelihood ratios, indicating a large change from prestest to posttest probability of glaucoma. These results suggest that the finding of an abnormal result in any of these tests, when assessing a patient suspect of having glaucoma, would substantially raise the probability of disease. Results of the evaluation of patients with preperimetric glaucoma also suggest that all three instruments are able to detect early glaucomatous structural damage in the absence of visual field loss
97

Comparação entre diversas técnicas de imagem para diagnóstico do glaucoma / Comparison of different imaging techniques to diagnose glaucoma

Roberto Murad Vessani 20 March 2008 (has links)
O objetivo desse estudo foi comparar a habilidade da avaliação subjetiva do disco óptico e da camada de fibras nervosas (CFN) por oftalmologistas generalistas e por um glaucomatólogo com medidas objetivas pela tomografia de coerência óptica (Stratus OCT), oftalmoscopia confocal de varredura a laser (HRTIII), e a polarimetria de varredura a laser (GDxECC) para discriminar olhos glaucomatosos de olhos normais. 61 olhos glaucomatosos e 57 olhos normais de 118 indivíduos foram incluídos nesse estudo. Três oftalmologistas generalistas independentes e um glaucomatólogo avaliaram fotografias estereoscópicas do disco óptico. Curvas ROC (Receiver Operator Characteristic) foram construídas para cada técnica de imagem e a sensibilidade a uma especificidade fixa foi determinada. Comparações das áreas sob essas curvas (AROC) e a concordância (k) foram determinadas entre a graduação das fotografias estereoscópicas e o melhor parâmetro de cada exame de imagem computadorizado. O melhor parâmetro de cada técnica de imagem computadorizada (CFN temporal inferior do Stratus OCT = 0,92; área integrada vertical da topografia do disco óptico pelo Stratus OCT = 0,86; espessura macular do setor inferior externo fornecido pelo Stratus OCT = 0,82; NFI do GDxECC = 0,91; razão área E/D do HRT3 = 0,83) mostrou AROC maior do que a graduação das fotografias estereoscópicas por oftalmologistas generalistas (0,80) para separar olhos glaucomatosos de olhos normais. A graduação por glaucomatólogo forneceu AROC igual ou maior (0,92) do que o melhor parâmetro de exame computadorizado de imagem. A avaliação das fotografias estereoscópicas por glaucomatólogo mostrou melhor concordância com o melhor parâmetro de cada técnica de imagem quantitativa na classificação de olhos como glaucomatosos ou normais comparadas à avaliação de fotografias estereoscópicas por oftalmologistas generalistas. A combinação da avaliação subjetiva do disco óptico por oftalmologistas generalistas com parâmetros objetivos da CFN melhorou a identificação de olhos com glaucoma em uma proporção maior do que a combinação desses parâmetros objetivos com a avaliação do disco óptico por um glaucomatólogo (29,5% versus 19,7%, respectivamente). Os resultados sugerem que a habilidade diagnóstica de todos os exames de imagem computadorizados estudados mostrou melhor desempenho que a avaliação subjetiva do disco óptico por oftalmologistas generalistas, mas não por um glaucomatólogo. Medidas objetivas da CFN podem permitir um aperfeiçoamento na detecção de glaucoma quando combinados com a avaliação subjetiva do disco óptico por oftalmologistas generalistas ou por um glaucomatólogo. / The purpose of this study was to compare the ability of subjective assessment of optic nerve head and retinal nerve fiber layer by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec, Inc.), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg, Germany), and scanning laser polarimetry (GDx ECC; Carl Zeiss Meditec, Inc., Dublin, CA) in discriminating glaucomatous and normal eyes. 61 glaucomatous and 57 normal eyes of 118 subjects were included in the study. Three independent general ophthalmologists and one glaucoma expert evaluated ONH stereophotographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons of areas under these curves (aROC) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Best parameter from each technique showed larger aROC (StratusOCT RNFL = 0.92; StratusOCT ONH vertical integrated area = 0.86; StratusOCT macular thickness = 0.82; GDxECC = 0.91; HRT3 global cup-to-disc area ratio = 0.83) compared to stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared to stereophoto grading by general ophthalmologists. The combination of subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with subjective assessment of the optic disc by a glaucoma expert (29.5% versus 19.7%, respectively). The results suggests that the diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by a glaucoma expert. Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.
98

Acurácia diagnóstica da ecocardiografia sob estresse associada ao estudo da perfusão miocárdica com contraste na avaliação da isquemia miocárdica: estudo comparativo entre adenosina e dobutamina / Diagnostic accuracy of quantitative real time myocardial contrast echocardiography for the detection of myocardial ischemia. A comparative study between adenosine and dobutamine

Ingrid Kowatsch 23 August 2005 (has links)
A ecocardiografia com perfusão miocárdica em tempo real (EPMTR) permite a quantificação do fluxo sangüíneo miocárdico e, quando realizada durante o estresse, da reserva de fluxo miocárdico (reserva Axß). Essa técnica tem potencial para ser uma importante ferramenta para o diagnóstico não-invasivo da doença arterial coronariana (DAC). Apesar do conhecimento atual das alterações fisiológicas que ocorrem com o uso de agentes vasodilatadores ou catecolaminas na circulação coronariana, não há dados na literatura comparando diretamente o valor da EPMTR, sob estresse pela dobutamina e pela adenosina, para a detecção de DAC em humanos. Os objetivos deste estudo foram: avaliar, em um mesmo grupo de pacientes, a exeqüibilidade e a acurácia da EPMTR, sob estresse pela dobutamina e pela adenosina, para a detecção de estenose arterial coronariana angiograficamente significativa e determinar o valor adicional da análise quantitativa da perfusão miocárdica sobre o eletrocardiograma de 12 derivações, da motilidade segmentar e da análise qualitativa da perfusão miocárdica obtidas durante o estresse pela dobutamina e pela adenosina. Estudamos 54 pacientes (média etária de 60±9 anos, 33 homens) com suspeita clínica de DAC e indicação de angiografia coronariana. Todos os pacientes foram submetidos à EPMTR sob estresse pela adenosina na dose de 140 g/kg/min por seis minutos e, após um intervalo de três a cinco horas, à EPMTR sob estresse pela dobutamina-atropina. O contraste ecocardiográfico utilizado foi o PESDA (Perfluorocarbon-Exposed Sonicated Dextrose and Albumin), administrado por via intravenosa periférica de forma contínua. Para ambas as EPMTR sob estresse pela dobutamina e pela adenosina, foram feitas análises do eletrocardiograma em 12 derivações (ECG), da motilidade segmentar e análise qualitativa e quantitativa da perfusão miocárdica. A quantificação da velocidade do fluxo miocárdico (ß) e do fluxo sangüíneo miocárdico (Axß) foi realizada por meio da utilização do programa computacional QLab 3.0 (Philips Medical Systems, Bothell, WA, USA). Todos os pacientes foram submetidos à angiografia coronariana quantitativa (ACQ) em um intervalo de até 30 dias da EPMTR. Foi considerada DAC a presença de lesão coronariana > 50% do diâmetro luminal. Dos 54 pacientes estudados, 25 (46%) apresentaram lesão coronariana >50% e 29 (54%) não apresentaram lesão coronariana significativa. A exeqüibilidade da quantificação da reserva Axß foi semelhante para a EPMTR sob estresse pela adenosina e pela dobutamina (91% versus 90% dos territórios arteriais; p = ns). A variabilidade da quantificação interobservador para os parâmetros de reserva ß e Axß foi de 6,8% (r = 0,98) e 5,5% (r = 0,97), respectivamente. A variabilidade intra-observador para os mesmos parâmetros foi de 2,1 % (r = 0,99) e 7,4 % (r = 0,95), respectivamente. A análise quantitativa da perfusão miocárdica, obtida pela EPMTR sob estresse pela dobutamina, apresentou sensibilidade de 84%, especificidade de 76% e acurácia de 80% para a detecção de DAC, enquanto que a EPMTR sob estresse pela adenosina apresentou sensibilidade de 88%, especificidade de 72% e acurácia de 80%. O valor incremental das modalidades estudadas para o diagnóstico de DAC foi analisado em modelo que incluiu o ECG, ECG e motilidade segmentar, ECG e motilidade segmentar e perfusão qualitativa e, por último, ECG e motilidade segmentar e perfusão qualitativa e quantitava, tanto para a EPMTR sob estresse pela dobutamina como pela adenosina (2 de 4,9 versus 20,1 versus 23,7 versus 38,4) e (2 de 9,9 versus 20,1 versus 26,7 versus 59,4), respectivamente. Concluímos que a avaliação quantitativa da EPMTR apresenta boa exeqüibilidade. A EPMTR sob estresse pela dobutamina e a pela adenosina apresentam acurácias diagnósticas similares para a detecção de lesão angiograficamente significativa. A análise quantitativa da perfusão miocárdica apresenta valor diagnóstico adicional aos outros parâmetros obtidos durante o estresse pela dobutamina e adenosina. / Real time myocardial contrast echocardiography (RTMCE) has allowed for the quantification of myocardial blood flow reserve (MBFR). This technique is a valuable tool for the noninvasive detection of coronary artery disease (CAD). Both adenosine and dobutamine are currently used stressor agents during RTMCE. Although it has already been shown the effects of these drugs on the coronary physiology, no study has directly compared both agents during RTMCE. The aims of this study were to determine the feasibility and diagnostic accuracy of adenosine versus dobutamine stress RTMCE for the detection of angiographically significant CAD. In addition, we sought to determine the additional value of quantitative RTMCE over the electrocardiogram, wall motion, and qualitative analysis of myocardial perfusion. The study involved 54 patients (60±9 years, 33 men) with suspected CAD. Patients underwent RTMCE at rest and during continuous infusion of 140g/kg/min of adenosine for six minutes, and dobutamine stress. The contrast agent used in the study was PESDA (Perfluorocarbon-Exposed Sonicated Dextrose and Albumin) administered in continuous intravenous infusion. Quantification of plateau of acoustic intensity (A) and microbubble velocity () was performed off line using a specific software (QLab 3.0, Philips Medical Systems, Bothell, WA, USA). Myocardial blood flow was determined as Ax. Quantitative coronary angiography was performed in all patients within 30 days of RTMCE, and CAD was defined as >50% luminal diameter coronary stenosis. There were 25 (46%) patients with CAD and 29 (54%) patients without obstructive lesion. The feasibility of quantitative MBFR was the same for adenosine and dobutamine stress RTMCE (91% versus 90% in all arterial territories; p=ns). The intraobserver variabilities for the measurements of ß and Axß reserve were 2.1% (r = 0.99) and 7.4% (r = 0.95), respectively. The interobserver variabilities for the same parameters were 6.8% (r = 0.98) and 5.5% (r = 0.97), respectively. The sensitivity, specificity and diagnostic accuracy of ß reserve obtained during dobutamine stress RTMCE for detecting CAD were 84%, 76%, and 80%, respectively, and during adenosine stress RTMCE they were 88%, 72% and 80%. The incremental value for the diagnosis of CAD was analyzed in a model that included the EKG, EKG and wall motion, EKG and wall motion and qualitative perfusion analysis and finally, EKG and wall motion and qualitative and quantitative perfusion analysis, for dobutamine and adenosine RTMCE (2= 4,9 versus 20,1 versus 23,7 versus s 38,4) and (2= 9,9 versus 20,1 versus 26,7 versus 59,4), respectively. In conclusion, quantitative RTMCE is a feasible technique in patients with suspected CAD. Dobutamine and adenosine stress RTMCE had similar diagnostic accuracy for the detection of angiographically significant lesion. Quantitative analysis of myocardial perfusion had incremental diagnostic value over the other parameters obtained during both dobutamine and adenosine stress RTMCE.
99

"Diagnóstico de rejeição cardíaca celular em pacientes transplantados: utilidade do estudo regional da função cardíaca com Doppler tecidual" / Diagnosis of cellular acute cardiac allograft rejection: usefulness of the regional study of heart function using pulsed Doppler tissue imaging

Marcos Valério Coimbra de Resende 19 August 2005 (has links)
Para o diagnóstico de rejeição celular foi utilizado o Doppler tecidual para o estudo da movimentação miocárdica de 14 regiões de 54 pacientes transplantados que realizaram 129 biópsias endomiocárdicas do ventrículo direito. Foram comparadas as médias e desvios padrão das velocidades de movimentação entre os pacientes com e sem rejeição celular = 3A.Verificou-se que a velocidade de movimentação diastólica tardia do anel lateral do ventrículo esquerdo quando menor do que 5,6 cm/s, isoladamente, apresentou sensibilidade de 73,8% e na análise multivariada encontrou-se modelo matemático com um conjunto de seis parâmetros, com sensibilidade de 88,2% para o diagnóstico de rejeição celular = 3A / For the diagnosis of cellular acute cardiac allograft rejection pulsed tissue Doppler imaging was used for measuring myocardial wall motion of 14 sites of 54 transplant patients who underwent 129 endomyocardial biopsies.The mean and standard deviation of myocardial velocities among patients displaying or not acute rejection = 3A were compared.It was observed that the analysis of late diastolic mitral annular motion at lateral site on its own showed a sensibility of 73.8% (5.6 cm/s was the best cut off value) and in the multivariate analysis a mathematical model was found with a set of 6 parameters with a sensibility of 88.2% for the diagnosis of cellular rejection = 3A
100

Validação do Teste de ativação de basófilos no diagnóstico de reações de hipersensibilidade a anti-inflamatórios não esteroidais / Validation of basophil activation test for the diagnosis of hypersensitivity reactions to nonsteroidal antiinflammatory drugs

Misumi, Denise Shimbo 10 May 2013 (has links)
Introdução: Atualmente, o diagnóstico das reações de hipersensibilidade a anti-inflamatórios não esteroidais (AINEs) baseia-se na história relatada pelo paciente e, em determinados casos, é realizado o Teste de Provocação. Todavia, este teste pode expor os pacientes a riscos graves, inclusive anafilaxia. Em busca de ferramenta mais segura, tem-se estudado o Teste de Ativação de Basófilos (BAT). Trata-se de um teste in vitro, no qual é possível testar diversos estímulos em uma única amostra de sangue, avaliando a ativação dos basófilos (indicativo de reação de hipersensibilidade), através do aumento da expressão de moléculas na superfície desses leucócitos, como o CD63. Objetivo: Padronizar e validar o BAT para ácido acetilsalicílico (AAS), diclofenaco, dipirona e paracetamol em pacientes com hipersensibilidade a AINEs. Metodologia: Participaram 20 (testados com os quatro AINEs) + 33 (testados somente com AAS) pacientes atendidos no Serviço de Imunologia Clínica e Alergia do HCFMUSP, que apresentaram manifestações cutâneas em até 24 horas após exposição a um ou múltiplos AINEs, bem como 13 (quatro AINEs) + 26 (AAS) controles. A técnica consistiu em incubar sangue total com os AINEs já mencionados e, depois, marcar as amostras com anticorpos monoclonais (CD45, anti-IgE e CD63) para posterior leitura por citometria de fluxo. Os resultados obtidos foram comparados com as histórias clínicas e os testes de provocação oral, quando realizados. Resultados: Utilizando os critérios de positividade do BAT empregados na literatura (isto é, porcentagem de CD45+IgE+highCD63+ e índice de estimulação), a sensibilidade e a especificidade variaram de acordo com o AINE: para ácido acetilsalicílico foram 75,0% e 16,7%, respectivamente, diclofenaco, 100% e 0%, dipirona, 23,5% e 66,7%, paracetamol, 40,0% e 42,9%. Após a realização de curvas dose-resposta e tempo-resposta somente com AAS, foi encontrado novo critério de positividade: média de intensidade de fluorescência (MFI) menor do que 6575 representava BAT positivo; com isso, os valores de sensibilidade e especificidade foram: 84,4% e 34,6%, respectivamente. O BAT foi mais sensível em pacientes cuja última reação ocorreu há menos de um ano da data de execução do BAT (93,7%). Conclusão: Devido aos baixos valores de sensibilidade e/ou especificidade, não foi possível padronizar e, por conseguinte, validar o BAT para ácido acetilsalicílico, diclofenaco, dipirona e paracetamol. / Introduction: Currently, the diagnosis of nonsteroidal antiinflammatory drugs (NSAIDs) hypersensivitity is based on patients´ clinical history and drug provocation tests, which are done in selected cases. Nevertheless, this test may expose patients to severe risks, including anaphylaxis. Looking for a safer tool, Basophil Activation Test (BAT) for allergy diagnosis has been studied in the last years. It is an in vitro method where a wide variety of stimuli can be tested, incubating them with the patient\'s blood sample, and observing basophil activation (indication of hypersensitivity) through upregulation of CD63 (or other basophil activation markers) on this leucocyte\'s membrane. Objective: To standardize and validate BAT stimulated with acetylsalicylic acid (ASA), diclophenac, dipyrone and paracetamol in NSAID hypersensitive patients. Methods: Patients which reported immediate reactions (less than 24 hours) after exposure to one or multiple NSAIDs, with cutaneous symptoms were enrolled from Clinical Immunology and Allergy outpatient clinic from HC-FMUSP. BAT with the four NSAIDs was tested on 20 patients and 13 controls and BAT with ASA only, on 33 patients and 26 controls. BAT consisted of incubating whole blood with NSAIDs, then triple-labeled with monoclonal antibodies (CD45, anti-IgE, CD63) for analysis by flow cytometry. BAT results were compared to clinical history and oral provocation tests, when available. Results: According to literature\'s positivity criteria (percentage of CD45+IgE+highCD63+ and stimulation index), sensitivity and specificity varied according to the NSAID tested: for ASA was 75.0% and 16.7% respectively, diclophenac, 100.0% and 0.0%, dipyrone, 23.5% and 66.7%, paracetamol, 40.0% and 42.9%. A new positivity criterion was possible to be defined after further dose-response and time-response curves only for ASA: Mean Fluorescence Intensity lower than 6575 (positive BAT). Accordingly, new sensitivity and specificity for BAT in ASA hypersensitivity were 84,4% and 34,6%. Patients that presented the last reaction in the last year were more likely to present a positive BAT (93.7%). Conclusion: Due to low values for sensitivity and/or specificity, it was not possible to standardize and validate BAT for ASA, diclophenac, dipyrone and paracetamol.

Page generated in 0.0236 seconds