• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 38
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 38
  • 38
  • 20
  • 15
  • 11
  • 11
  • 8
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Adsorção de IgG humana em duas matrizes porosas derivatizadas com o ligante histidina

Aquino, Luciana Cristina Lins de 26 July 2018 (has links)
Orientadores: Sonia Maria Alves Bueno, Paulo de Tarso Vieira e Rosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-07-26T21:37:07Z (GMT). No. of bitstreams: 1 Aquino_LucianaCristinaLinsde_M.pdf: 5114792 bytes, checksum: e7d2de55259ac53d6cb7ff9c538344a9 (MD5) Previous issue date: 2000 / Resumo: A técnica de adsorção por afinidade, que utiliza adsorventes com alta seletividade para adsorver compostos, principalmente proteínas, tem sido empregada para remover autoanticorpos do plasma de pacientes com doenças auto-imunes e também na produção em larga escala de drogas terapêuticas através do ftacionamento do plasma humano ou animal. Na circulação extracorpórea o plasma do paciente é alimentado em uma coluna contendo um ligante imobilizado em uma matriz insolúvel que remove os auto-anticorpos, e as proteínas não adsorvidas retomam para o paciente sem nenhuma alteração. Na busca de sistemas adequados para a aplicação no tratamento de doenças auto-imunes, esta pesquisa investiga a adsorção de IgG em dois suportes de afinidade empregando a histidina como ligante, imobilizado em membranas de fibras ocas de álcool poli etileno vinílico (pEV A) e gel de copolímero de metacrilato (Toyopearl), denominados His-PEV A e His- Toyopearl, respectivamente. Sendo verificada a possibilidade de adsorção de IgG em ambos suportes, experimentos de seletividade e de capacidade de adsorção em modo dinâmico e estático demonstraram uma maior eficiência para o sistema His-PEV A do que para o HisToyopearl, tanto na presença do tampão Hepes a pH 7,0 como do Tris-HCI pH a 7,4. Através da obtenção de isotermas de adsorção, para os suportes com e sem ligante, à temperatura ambiente e à 37 °C, foi constatada a existência de interações não-específicas entre a proteína e a matriz, sendo necessário efetuar as etapas de lavagem, eluição e regeneração, após ser atingido o equilíbrio de adsorção, para obter a quantidade de proteína adsorvida especificamente nos suportes. A determinação de parâmetros como a capacidade máxima de adsorção, a constante de dissociação do complexo IgG-histidina (KJ) e as constantes cinéticas de adsorção (Iça) de dessorção (kd) de proteína, indicaram que apesar de ambos sistemas apresentarem uma afinidade pela proteína da mesma ordem de grandeza (lO-sM), o suporte His-PEV A apresenta uma maior capacidade para a adsorção específica de proteína, nas temperaturas analisadas / Abstract: Affinity adsorption explores the characteristics that certain compounds have to selectively interact with substances or classes of substances. This technique has been used to purify proteins in small and large scale and also to remove autoantibodies from plasma of autoimmune patients. In an extracorporeal treatment, the autoantibodies are retained in a column that contains an affinity ligand immobilized in an insoluble matrix. The unretained fraction containing the plasma proteins different from the autoantibodies can be returned to the patient. In this work, the behavior of IgG adsorption either onto poly ethylene vinyl alcohol (pEV A) hollow-fiber membranes or onto metacrylate gels (Toyopearl) containing histidine as affinity ligand was studied. The IgG adsorption in both supports was feasable. The selectivity studies as well as the static and dynamic adsorption experiments showed that the IgG adsorption onto PEV A hollow-fibers was more efficient than onto Toyopearl, independently ifHepes pH 7.0 or Tris-HCI 7.4 buffer were used. The adsorption isotherms of IgG in the supports with or without ligand showed that there is also non-specific adsorption of the protein onto the matrix surface. The amount of specifically adsorbed protein was determined by the elution and regeneration of the support following extensive washing of the particles with buffer. The values of the adsorption capacity constant (Qm), dissociation constant of the IgG-histidine complex (Kd), adsorption constant (ka), and desorption constant (kd) indicated that both systems have approximately the same affinity for the IgG (10.5 M) and that PEV A hollow-fibers have a large specific adsorption capacity. This behavior was observed for temperatures of25 and 37°C / Mestrado / Desenvolvimento de Processos Biotecnologicos / Mestre em Engenharia Química
12

Avaliação in vitro de tubos de PVC recobertos utilizados em procedimentos de circulação extracorporea

Moreira, Patricia da Luz 27 July 2018 (has links)
Orientador: Selma Candelaria Genari / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-07-27T13:27:22Z (GMT). No. of bitstreams: 1 Moreira_PatriciadaLuz_M.pdf: 3271080 bytes, checksum: d643afabc75067c1fb09b793ca29e709 (MD5) Previous issue date: 2001 / Mestrado
13

Oximetria de pulso na avaliação do transporte de oxigenio em pacientes criticos

Nunes, Wilma Aparecida 18 July 2018 (has links)
Orientador : Renato G. G. Terzi / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-07-18T17:41:50Z (GMT). No. of bitstreams: 1 Nunes_WilmaAparecida_M.pdf: 4789221 bytes, checksum: e756ea292d5c5d779c09c4252ab320cd (MD5) Previous issue date: 1993 / Resumo: A oximetria de pulso constitui um avanço tecnológico que permite a monitorização, de forma contínua e não invasiva, da saturação de oxigênio no sangue arterial. Neste estudo, a monitorização de 35 pacientes de terapia intensiva, submetidos a ventilação mecânica, permitiu estabelecer o nível de precisão de dois oxímetros de pulso de diferentes fabricantes. O desempenho foi determinado em função de dados comparativos obtidos pela hemo-oximetria e para proceder a análise estatística, foi utilizado o teste t. A exatidão (médias das diferenças) não se mostrou diferente entre os oxímetros de pulso quando comparados com a hemo-oximetria, entretanto, o pulsat IMR, apresenta maior precisão (desvio padrão das diferenças). Pacientes críticos são portadores de condições clínicas que podem, eventualmente, limitar o uso desta técnica. No presente trabalho foi demonstrado que a discrepância nos resultados obtidos pode ser atribuída a presença de metemoglobina e possivelmente à anemia associada a hipóxia...Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: Pulse oximetry is a new technological develompment that permit continuous and noninvasive monitoring of the oxygen saturation of the arterial blood. I this clinical investigation 35 patients under mechanical ventilation were studied. It was possible to establish the precision of two pulse oximeters of different brands. The performance of these equipments was evaluated by comparing data with hemo-oximeter, statistical analysis employed the student t test. The results showed that bias (mean differences) bet ween oximeters readings and hemo-oximeter was similar for both instruments.However, precision (standard deviation of differences) resulted higher with Pulsat IMR then with SatitleTRANS TMR. Tually critical patients may be limited for the use of this technique. In this study it was showed that discrepancy in the results observed, may be attributed to the presence of the methemoglobin and possible to anaemia associated to hypoxia...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Fisiologia / Mestre em Ciências Biológicas
14

Análise comparativa da incidência de hemólise e resposta inflamatória sistêmica induzida pela circulação extracorpórea em bomba de roletes e em bomba centrífuga em cirurgia de revascularização do micárdio /

Passaroni, Andréia Cristina. January 2015 (has links)
Orientador: Winston Bonetti Yoshida / Coorientador: Marcos Augusto de Moraes Silva / Banca: Marcello Laneza Felicio / Banca: Nelson Leonardo Kerdahi Leite de Campos / Banca: Reinaldo Ayer de Oliveira / Banca: Nilson Antunes / Resumo: Objetivo: Relatar de forma simples e resumida o desenvolvimento da circulação extracorpórea. Métodos: Realizada revisão de literatura sobre a evolução da circulação extracorpórea, seu papel fundamental para cirurgia cardiovascular e as complicações que podem surgir após o seu uso, dentre elas, a hemólise e a inflamação. Resultados: O processo de desenvolvimento da circulação extracorpórea foi fundamental diminuindo as complicações desencadeadas por ela, que acabam por repercutir no paciente, variando de lesões de graus variados até falência de múltiplos órgãos. Os pesquisadores estudaram quais as agressões que a CEC poderia suscitar no organismo humano. Possíveis soluções surgiram e consequentemente, meios mais adequados para uma condução mais segura do pós-operatório foram propostas. Conclusão: A CEC progrediu a passos firmes e seguros ao longo destas últimas décadas desde a sua concepção por Gibbon. Apesar da sua evolução e das condutas realizadas na tentativa de amenizar as complicações, o respeito aos detalhes das funções fisiológicas do paciente são fundamentais / Abstract: Objective: To provide a brief review of the development of cardiopulmonary bypass. Methods: A review of the literature on the development of extracorporeal circulation techniques, their essential role in cardiovascular surgery, and the complications associated with their use, including hemolysis and inflammation. Results: The advancement of extracorporeal circulation techniques has played an essential role in minimizing the complications of cardiopulmonary bypass, which can range from various degrees of tissue injury to multiple organ dysfunction syndrome. Investigators have long researched the ways in which cardiopulmonary bypass may insult the human body. Potential solutions arose and laid the groundwork for development of safer postoperative care strategies. Conclusion: Steady progress has been made in cardiopulmonary bypass in the decades since it was first conceived of by Gibbon. Despite the constant evolution of cardiopulmonary bypass techniques and attempts to minimize their complications, it is still essential that clinicians respect the particularities of each patient's physiological function / Doutor
15

Aplicação do sistema de biosusceptometria AC para monitoramento de nanopartículas magnéticas na circulação sanguínea /

Próspero, André Gonçalves. January 2015 (has links)
Orientador: José Ricardo de Arruda Miranda / Coorientador: Patricia Fidelis de Oliveira Gregolini / Banca: Joel Mesa / Banca: Andris Figueiroa Bakuzis / Resumo: As técnicas biomagnéticas possibilitam o estudo de diversos parâmetros fisiológicos através da detecção de campos magnéticos gerados por correntes biológicas ou por marcadores/traçadores magnéticos. Uma das técnicas utilizadas dentro desta vertente é a Biosusceptometria de Corrente Alternada (BAC). A técnica utiliza um sistema gradiométrico de bobinas para monitorar posição e concentração de materiais magnéticos em sistemas biológicos. A partir do monitoramento realizado pelo sistema, é possível obter dados relacionados com as propriedades biológicas locais e estabelecer parâmetros mecânico-fisiológicos, principalmente do trato gastrintestinal, como esvaziamento e atividade de contração gástrica. A proposta deste trabalho é inédita e consiste na aplicação do sistema BAC, associado à nanopartículas magnéticas utilizadas como traçadores, a fim de, futuramente, disponibilizar uma nova ferramenta para estudos de caracterização pré-clínica de nanopartículas magnéticas. Foram realizados experimentos com ratos para a quantificação do tempo de meia vida das nanopartículas magnéticas em intervalos de tempo pré definidos, além do tempo de chegada das partículas no coração dos animais, bem como sua biodistribuição. Como testes adicionais, foram realizadas quantificações de alterações em parâmetros cardiovasculares sobre a administração endovenosa das nanopartículas magnéticas, já que esses parâmetros cardiovasculares influenciam diretamente no tempo de meia vida e biodistribuição do material. O sistema demonstrou bom desempenho em todos os testes aplicados, apresentando excelente reprodutibilidade, sensibilidade e resolução temporal. Os resultados sugerem a utilização da BAC como método de avaliação de parâmetros de caraterização pré-clínica de nanopartículas magnéticas em organismos vivos, em avaliações de biodistribuição e tempo de meia vida das nanopartículas... / Abstract: In the Biomagnetic research field, several methods have reported to study physiological parameters through the detection of magnetic fields generated by biological electrical currents or magnetic marker/tracers. Among such techniques, the Alternating Current Biosusceptometry (AC Biosusceptometry or ACB) system has been developed and refined with the main purpose of detecting and monitoring magnetic materials in biological systems (mainly in the gastrointestinal tract so far). With a pair of gradiometric pickup coils, the ACB system is able to obtain data related to local biological properties and also to study mechanical and physiological parameters, such as gastric emptying and contraction activity. This work presents an unprecedented study that applies the ACB system, associated to magnetic nanoparticles, as a new tool for preclinical characterization of magnetic nanoparticles. In vivo Experiments were performed in rat models to quantify the magnetic nanoparticles half-life in predefined time intervals, the particles arrival time in the animals heart and also the nanoparticles biodistribution. As an additional test, cardiovascular parameters were acquired during the particle intravenous administration, since these parameters directly influence the material half-life and biodistribution. The system presented good performance in all tests, with excellent reproducibility, sensitivity and temporal resolution. Also, these results suggest the ACB using as valuable evaluation method for magnetic nanoparticles preclinical characterization, in parameters as biodistribution and half-life in the bloodstream, since transient changes in mean arterial pressure and heart rate were found due to the magnetic nanoparticles intravenous administration. This work includes the development and characterization of a new low cost physics instrumentation, to subsidize circulatory system research, in small animals, and new nanostructured materials applications ... / Mestre
16

A expressão de proteinas de proliferação e diferenciação celular em cardiomiócitos durante a transição da circulação fetal a vida extra-uterina / Tarcísio Fulgêncio Alves da Silva ; orientadora, Lúcia de Noronha

Silva, Tarcísio Fulgêncio Alves da January 2009 (has links)
Tese (doutorado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2009. / Bibliografia: f. 73-77 / A passagem da condição de feto à vida extra-uterina exige adaptações anatômicas e fisiológicas fundamentais à sobrevivência. O estudo das alterações cardíacas nesta fase transitória vem sendo explorado por inúmeras pesquisas, que buscam compreender este p / The passage from the fetal condition to the extra-uterine life demands physiological and anatomic adaptations, which are fundamental to the life. The study of cardiac alterations in this transitory phase has been explored in several researches, which aim
17

Aplicação do sistema de biosusceptometria AC para monitoramento de nanopartículas magnéticas na circulação sanguínea

Próspero, André Gonçalves [UNESP] 26 February 2015 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-26. Added 1 bitstream(s) on 2015-12-10T14:28:28Z : No. of bitstreams: 1 000848395.pdf: 2504523 bytes, checksum: 3e311603d829f6daa3c4f95a93b6adbd (MD5) / As técnicas biomagnéticas possibilitam o estudo de diversos parâmetros fisiológicos através da detecção de campos magnéticos gerados por correntes biológicas ou por marcadores/traçadores magnéticos. Uma das técnicas utilizadas dentro desta vertente é a Biosusceptometria de Corrente Alternada (BAC). A técnica utiliza um sistema gradiométrico de bobinas para monitorar posição e concentração de materiais magnéticos em sistemas biológicos. A partir do monitoramento realizado pelo sistema, é possível obter dados relacionados com as propriedades biológicas locais e estabelecer parâmetros mecânico-fisiológicos, principalmente do trato gastrintestinal, como esvaziamento e atividade de contração gástrica. A proposta deste trabalho é inédita e consiste na aplicação do sistema BAC, associado à nanopartículas magnéticas utilizadas como traçadores, a fim de, futuramente, disponibilizar uma nova ferramenta para estudos de caracterização pré-clínica de nanopartículas magnéticas. Foram realizados experimentos com ratos para a quantificação do tempo de meia vida das nanopartículas magnéticas em intervalos de tempo pré definidos, além do tempo de chegada das partículas no coração dos animais, bem como sua biodistribuição. Como testes adicionais, foram realizadas quantificações de alterações em parâmetros cardiovasculares sobre a administração endovenosa das nanopartículas magnéticas, já que esses parâmetros cardiovasculares influenciam diretamente no tempo de meia vida e biodistribuição do material. O sistema demonstrou bom desempenho em todos os testes aplicados, apresentando excelente reprodutibilidade, sensibilidade e resolução temporal. Os resultados sugerem a utilização da BAC como método de avaliação de parâmetros de caraterização pré-clínica de nanopartículas magnéticas em organismos vivos, em avaliações de biodistribuição e tempo de meia vida das nanopartículas... / In the Biomagnetic research field, several methods have reported to study physiological parameters through the detection of magnetic fields generated by biological electrical currents or magnetic marker/tracers. Among such techniques, the Alternating Current Biosusceptometry (AC Biosusceptometry or ACB) system has been developed and refined with the main purpose of detecting and monitoring magnetic materials in biological systems (mainly in the gastrointestinal tract so far). With a pair of gradiometric pickup coils, the ACB system is able to obtain data related to local biological properties and also to study mechanical and physiological parameters, such as gastric emptying and contraction activity. This work presents an unprecedented study that applies the ACB system, associated to magnetic nanoparticles, as a new tool for preclinical characterization of magnetic nanoparticles. In vivo Experiments were performed in rat models to quantify the magnetic nanoparticles half-life in predefined time intervals, the particles arrival time in the animals heart and also the nanoparticles biodistribution. As an additional test, cardiovascular parameters were acquired during the particle intravenous administration, since these parameters directly influence the material half-life and biodistribution. The system presented good performance in all tests, with excellent reproducibility, sensitivity and temporal resolution. Also, these results suggest the ACB using as valuable evaluation method for magnetic nanoparticles preclinical characterization, in parameters as biodistribution and half-life in the bloodstream, since transient changes in mean arterial pressure and heart rate were found due to the magnetic nanoparticles intravenous administration. This work includes the development and characterization of a new low cost physics instrumentation, to subsidize circulatory system research, in small animals, and new nanostructured materials applications ...
18

Análise comparativa da incidência de hemólise e resposta inflamatória sistêmica induzida pela circulação extracorpórea em bomba de roletes e em bomba centrífuga em cirurgia de revascularização do micárdio

Passaroni, Andréia Cristina [UNESP] 20 February 2015 (has links) (PDF)
Made available in DSpace on 2016-06-07T17:12:04Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-20. Added 1 bitstream(s) on 2016-06-07T17:16:34Z : No. of bitstreams: 1 000866141.pdf: 1957623 bytes, checksum: 60c7529f121b515c25eb6ccedc57c216 (MD5) / Objetivo: Relatar de forma simples e resumida o desenvolvimento da circulação extracorpórea. Métodos: Realizada revisão de literatura sobre a evolução da circulação extracorpórea, seu papel fundamental para cirurgia cardiovascular e as complicações que podem surgir após o seu uso, dentre elas, a hemólise e a inflamação. Resultados: O processo de desenvolvimento da circulação extracorpórea foi fundamental diminuindo as complicações desencadeadas por ela, que acabam por repercutir no paciente, variando de lesões de graus variados até falência de múltiplos órgãos. Os pesquisadores estudaram quais as agressões que a CEC poderia suscitar no organismo humano. Possíveis soluções surgiram e consequentemente, meios mais adequados para uma condução mais segura do pós-operatório foram propostas. Conclusão: A CEC progrediu a passos firmes e seguros ao longo destas últimas décadas desde a sua concepção por Gibbon. Apesar da sua evolução e das condutas realizadas na tentativa de amenizar as complicações, o respeito aos detalhes das funções fisiológicas do paciente são fundamentais / Objective: To provide a brief review of the development of cardiopulmonary bypass. Methods: A review of the literature on the development of extracorporeal circulation techniques, their essential role in cardiovascular surgery, and the complications associated with their use, including hemolysis and inflammation. Results: The advancement of extracorporeal circulation techniques has played an essential role in minimizing the complications of cardiopulmonary bypass, which can range from various degrees of tissue injury to multiple organ dysfunction syndrome. Investigators have long researched the ways in which cardiopulmonary bypass may insult the human body. Potential solutions arose and laid the groundwork for development of safer postoperative care strategies. Conclusion: Steady progress has been made in cardiopulmonary bypass in the decades since it was first conceived of by Gibbon. Despite the constant evolution of cardiopulmonary bypass techniques and attempts to minimize their complications, it is still essential that clinicians respect the particularities of each patient's physiological function
19

Influência do controle vagal na resistência vascular pulmonar e desvio intracardíaco em Crotalus durissus (Squamata: Viperidae) /

Filogonio, Renato. January 2012 (has links)
Orientador: Augusto Shinya Abe / Coorientador: Cleo Alcantara Costa Leite / Banca: José Eduardo de Carvalho / Banca: Luiz Henrique Florindo / Resumo: Em répteis não crocodilianos, o ventrículo parcialmente dividido permite que o sangue venoso pobre em oxigênio recircule no circuito sistêmico, configurando um desvio sanguíneo intracardíaco ("shunt") da direita para a esquerda (DSIc D-E), ou que o sangue arterial rico em oxigênio retorne ao circuito pulmonar, configurando um desvio sanguíneo intracardíaco da esquerda para a direita (DSIc E-D). Teoricamente, se o DSIc apresentar alguma vantagem adaptativa, seria controlado, ao invés de uma mera consequência passiva do sistema circulatório às mudanças das resistências vasculares. O nervo vago inerva o tronco pulmonar e possui influência no controle da resistência do circuito pulmonar. Assim, o aumento ou diminuição desta resistência poderia definir a direção do desvio sanguíneo resultante. Neste estudo foi postulada a hipótese de que a ausência do tônus vagal causaria mudanças no controle do DSIc em animais submetidos a variações na temperatura e na atividade. Para tanto, foram comparados dois grupos de cascavéis, Crotalus durissus, com nervo vago intacto ou seccionado, submetidas às mesmas condições de temperatura e de atividade. Os parâmetros hemodinâmicos foram aferidos através de canulação oclusiva. De forma geral, o aumento da temperatura e da atividade aumentaram a frequência cardíaca (fH), débito cardíaco (DC), fluxo sanguíneo pulmonar (Qpul) e fluxo sanguíneo sistêmico (Qsis), embora apenas a atividade tenha feito com que as serpentes desenvolvessem um DSIc E-D como resposta ao aumento da demanda de O2 nos tecidos. A atividade também foi responsável pelo aumento das pressões arteriais média sistêmica e pulmonar. A vagotomia unilateral também causa aumento dos fluxos sanguíneos, embora não afete a fH. A ausência do controle vagal tem maior efeito no controle da resistência... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In non crocodilian reptiles, the ventricle is partially divided and allows venous blood, low in oxygen, to recirculate the systemic circuit, which is referred to as a right-to-left shunt (R-L shunt), or the oxygen-rich blood to return to the pulmonary circuit, referred to as a left-to-right shunt (L-R shunt). In theory, if intracardiac shunts provide any adaptive advantage, it would be controlled rather than be a passive consequence of changes in vascular resistances. The vagus nerve innervates the pulmonary trunk and has a role in controlling the resistance of the pulmonary circuit (Rpul). Thus, the control of Rpul could set the direction of the resulting shunt. In this study we hypothesized that the lack of vagal tone causes changes in control of intracardiac shunts in animals subjected to variations in temperature and activity. Therefore, we compared two groups of South American rattlesnakes, Crotalus durissus, with the vagus nerve intact or severed, subjected to the same conditions of temperature and activity. Hemodynamic parameters were measured by occlusive cannulation. Generally, increasing the temperature and the activity increased heart rate (fH), cardiac output (CO), pulmonary blood flow (Qpul) and systemic blood flow (Qsys), although only activity has caused to develop a R-L shunt in response to increased demand for O2 in the tissues. The activity was also responsible for increase in mean systemic and pulmonary arterial pressure. Unilateral vagotomy also increased blood flow, but did not affect fH. The absence of vagal control has more effect in controlling Rpul, causing changes in shunt patterns, especially when the animal was active. Under such condition, the organism seemed to offset the effects on hemodynamic shunt, resulting from changes in systemic resistance, with changes in CO. Thus, CO is elevated until Qpul is at an... (Complete abstract click electronic access below) / Mestre
20

Influência do controle vagal na resistência vascular pulmonar e desvio intracardíaco em Crotalus durissus (Squamata: Viperidae)

Filogonio, Renato [UNESP] 01 November 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-11-01Bitstream added on 2014-06-13T19:18:42Z : No. of bitstreams: 1 filogonio_r_me_rcla.pdf: 657959 bytes, checksum: 37b2e2fd5df4b378bb998638fbf738c2 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Em répteis não crocodilianos, o ventrículo parcialmente dividido permite que o sangue venoso pobre em oxigênio recircule no circuito sistêmico, configurando um desvio sanguíneo intracardíaco (“shunt”) da direita para a esquerda (DSIc D-E), ou que o sangue arterial rico em oxigênio retorne ao circuito pulmonar, configurando um desvio sanguíneo intracardíaco da esquerda para a direita (DSIc E-D). Teoricamente, se o DSIc apresentar alguma vantagem adaptativa, seria controlado, ao invés de uma mera consequência passiva do sistema circulatório às mudanças das resistências vasculares. O nervo vago inerva o tronco pulmonar e possui influência no controle da resistência do circuito pulmonar. Assim, o aumento ou diminuição desta resistência poderia definir a direção do desvio sanguíneo resultante. Neste estudo foi postulada a hipótese de que a ausência do tônus vagal causaria mudanças no controle do DSIc em animais submetidos a variações na temperatura e na atividade. Para tanto, foram comparados dois grupos de cascavéis, Crotalus durissus, com nervo vago intacto ou seccionado, submetidas às mesmas condições de temperatura e de atividade. Os parâmetros hemodinâmicos foram aferidos através de canulação oclusiva. De forma geral, o aumento da temperatura e da atividade aumentaram a frequência cardíaca (fH), débito cardíaco (DC), fluxo sanguíneo pulmonar (Qpul) e fluxo sanguíneo sistêmico (Qsis), embora apenas a atividade tenha feito com que as serpentes desenvolvessem um DSIc E-D como resposta ao aumento da demanda de O2 nos tecidos. A atividade também foi responsável pelo aumento das pressões arteriais média sistêmica e pulmonar. A vagotomia unilateral também causa aumento dos fluxos sanguíneos, embora não afete a fH. A ausência do controle vagal tem maior efeito no controle da resistência... / In non crocodilian reptiles, the ventricle is partially divided and allows venous blood, low in oxygen, to recirculate the systemic circuit, which is referred to as a right-to-left shunt (R-L shunt), or the oxygen-rich blood to return to the pulmonary circuit, referred to as a left-to-right shunt (L-R shunt). In theory, if intracardiac shunts provide any adaptive advantage, it would be controlled rather than be a passive consequence of changes in vascular resistances. The vagus nerve innervates the pulmonary trunk and has a role in controlling the resistance of the pulmonary circuit (Rpul). Thus, the control of Rpul could set the direction of the resulting shunt. In this study we hypothesized that the lack of vagal tone causes changes in control of intracardiac shunts in animals subjected to variations in temperature and activity. Therefore, we compared two groups of South American rattlesnakes, Crotalus durissus, with the vagus nerve intact or severed, subjected to the same conditions of temperature and activity. Hemodynamic parameters were measured by occlusive cannulation. Generally, increasing the temperature and the activity increased heart rate (fH), cardiac output (CO), pulmonary blood flow (Qpul) and systemic blood flow (Qsys), although only activity has caused to develop a R-L shunt in response to increased demand for O2 in the tissues. The activity was also responsible for increase in mean systemic and pulmonary arterial pressure. Unilateral vagotomy also increased blood flow, but did not affect fH. The absence of vagal control has more effect in controlling Rpul, causing changes in shunt patterns, especially when the animal was active. Under such condition, the organism seemed to offset the effects on hemodynamic shunt, resulting from changes in systemic resistance, with changes in CO. Thus, CO is elevated until Qpul is at an... (Complete abstract click electronic access below)

Page generated in 0.0603 seconds