• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 652
  • 270
  • 152
  • 149
  • 62
  • 56
  • 22
  • 20
  • 16
  • 13
  • 13
  • 10
  • 8
  • 8
  • 7
  • Tagged with
  • 1697
  • 612
  • 180
  • 171
  • 139
  • 131
  • 123
  • 96
  • 85
  • 84
  • 84
  • 82
  • 82
  • 73
  • 71
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
291

The use of low energy photons in brachytherapy : dosimetric and microdosimetric studies around 103Pd and 125I seeds

Reniers, Brigitte 16 February 2005 (has links)
The general context of this work is the use of low energy photon sealed sources in brachytherapy. We have worked in particular on two isotopes: I-125 (mean energy of 27 keV) and Pd-103 (mean energy of 21 keV). The sealed sources are prepared as cylindrical seeds 4.5 mm in length and 0.8 mm in radius. Even if the external dimensions are standard, the internal design can be extremely different from one model to the other as the manufacturers try to improve the dosimetric characteristics of their sources. These isotopes are used mainly as permanent implants for prostate tumours but can also be used in the treatment of eye tumours. Compared to the higher energy photon sources, they offer the physical advantages of a safer manipulation from a radioprotection point of view and of the reduction of the dose to the surrounding healthy tissues. When performing a clinical treatment, it is absolutely mandatory to be able to report very precisely various parameters that can have an impact on the patient treatment outcomes. These parameters are, for example, the prescribed dose, the doses at different organs, the degree of uniformity that has been achieved on the target or some dose-volume information. The brachytherapy treatment planning systems (TPS) also permit more and more to conform the treatment to the patient anatomy, like in external treatments. In the case of prostate tumours, it has been possible for a few years, using ultrasound imaging, to check the positioning of the seeds and to calculate the dose distribution in real time during the implantation procedure. It is clear that to achieve a good precision in the treatment itself, the sources dosimetric characteristics must be known with a maximum of precision. As at these low energies the dosimetric characteristics are very dependant on the internal design, this implies a thorough study of any new source design. This is the subject of the first part of this work with the determination of the dosimetric characteristics of two new models of seed produced by the IBt Company. That determination has been done using measurements with thermoluminescent detectors and Monte Carlo calculations with two codes: MCNP4C and EGSnrc. The comparison of these two codes with the measurements has brought into evidence the necessity to use up to date cross section libraries during the calculations and to take into account the presence of the detectors during the measurements. However, the dosimetry is only one part of the problem when dealing with these low energy sources in radiotherapy. The irradiated materials are complex living tissues, composed of many substructures on which radiations have not always the same impact. It is now largely accepted that the most radiosensitive part of a living cell is the DNA. When photons interact with matter, they produce electrons that deposit their energy as ionisations and excitations of the atoms. These ionisations, if they occur with or close to the DNA molecule, are responsible for damaging it. That structure can support a certain amount of damage and stay functional thanks to repair mechanisms, but these mechanisms have limits in the way they can handle multiple breaks in the DNA strands. If these breaks are too close in space and time, repair is not possible and the cell dies. The density of ionisations increases when the energy of the incoming photon decreases so it is expected that low energy photons will have a higher efficiency at killing cells and so a higher Relative Biological Effect than high energy photons. To study that subject, one must reduce the volume of matter considered during energy deposition events to reach the sizes relevant for cells, micron or even nanometre volumes. That is why the part of radiation physics dealing with that problem is called microdosimetry. The second part of this work is dedicated to a theoretical microdosimetric study of these low energy photon sources using the microdosimetric functions for volumes of 1µm and a cluster analysis study for nanometric volumes. The two types of studies show that the photons of 20-30 keV are effectively more biologically efficient than high energy photons. The microdosimetric results give a ratio of the relative to Co-60 of 2.6 for Pd-103 and 2.2 for I-125, which is concordant with the experimental values published by Wuu et al. (1996). The cluster analysis also shows that the electrons generated by photons of 20-30 keV produce more high order clusters than electrons of 300 keV. The mean cluster order for clusters of 10 nm is 3.0 for Pd-103 and is 3.3 for I-125 compared to 2.1 for electrons of 300 keV. In this case, I-125 shows a higher mean cluster order, which is related to a potentially higher biological efficiency. This is explained by the fact that I-125 photons interact with a probability of 51% by Compton Effect, when that probability decreases to 27% for Pd-103. Compton interactions generate a high number of very low electrons that deposit their energy very locally with a very high density of ionisations. More radiobiological studies are needed to determine which volume site is more relevant and therefore which kind of study better reflects the reality. / Le cadre général de ce travail est l'utilisation de sources scellées de photons de basse énergie en curiethérapie. Nous avons travaillé en particulier avec deux isotopes : I-125 (énergie moyenne de 27 keV) et le Pd-103 (énergie moyenne de 21 keV). Les sources scellées se présentent sous la forme de grains cylindriques de 4.5 mm de long et 0.8 mm de rayon. Bien que les dimensions externes soient standards, la configuration interne peut être extrêmement différente d'un modèle à l'autre vu que les fabricants essaient d'améliorer les caractéristiques dosimétriques de leurs sources. Ces isotopes sont utilisés comme implants permanents pour les tumeurs de la prostate mais peuvent aussi être utilisés dans le traitement des tumeurs ophtalmiques. Comparés aux sources de plus haute énergie, ils offrent l'avantage physique d'une manipulation plus facile du point de vue de la radioprotection et d'une réduction de la dose aux tissus sains avoisinants. Lors d'un traitement clinique, il est important de pouvoir rapporter précisément certains paramètres qui peuvent avoir un impact sur les résultats du traitement pour le patient. Ces paramètres sont par exemple la dose prescrite, les doses à différents organes, le degré d'uniformité atteint sur le volume cible ou certaines information dose-volume. Les systèmes de calcul de dose pour la curiethérapie permettent également de mieux en mieux de conformer le traitement à l'anatomie du patient, comme en radiothérapie externe. Dans le cas des tumeurs de la prostate, il est possible depuis quelques années de vérifier la position des sources et de calculer les distributions de dose en temps réel lors de l'implantation grâce à l'utilisation d'une sonde ultrason. Il est clair que pour arriver à une bonne précision lors du traitement lui-même, il est indispensable de connaître les caractéristiques dosimétriques des sources avec un maximum de précision. Vu que, à ces basses énergies, les caractéristiques dosimétriques sont très dépendantes de la structure interne de sources, cela implique une étude minutieuse et complète de chaque nouveau modèle de grain mis sur le marché. Ceci forme le cadre de la première partie de ce travail qui est la détermination des caractéristiques dosimétriques de deux nouveaux modèles de grains produits par la compagnie IBt. Cette détermination a été réalisée grâce à l'utilisation de détecteurs thermoluminescents et de calculs de Monte Carlo avec deux codes : MCNP4C et EGSnrc. La comparaison de ces deux codes avec les mesures a permit de mettre en évidence la nécessité d'utiliser des bibliothèques de sections efficaces récentes lors des calculs et de prendre en compte la présence des détecteurs lors des mesures. Cependant, la dosimétrie est seulement une partie du problème de l'étude des sources de basse énergie utilisée en radiothérapie. Les milieux irradiés sont des tissus vivants complexes, composés de plusieurs sous-structures sur lesquelles les radiations n'ont pas toujours le même effet. Il est maintenant largement accepté que la partie la plus radiosensible d'une cellule vivante est la molécule d'ADN. Lorsque des photons interagissent avec la matière, ils produisent des électrons qui eux-mêmes déposent leur énergie sous forme d'ionisation et d'excitations des atomes. Ces ionisations, si elles se passent à proximité ou dans la molécule d'ADN, peuvent endommager celle-ci. Cette structure peut supporter une certaine quantité de dommages tout en restant fonctionnelle grâce à des mécanismes de réparation, mais ces mécanismes connaissent des limitations dans la manière dont ils peuvent gérer les cassures multiples des brins d'ADN. Si ces cassures sont trop proches dans le temps et l'espace, la réparation n'est plus possible et la cellule meurt. La densité d'ionisation augmente lorsque l'énergie du photon décroît. Il est donc attendu que les photons de basse énergie auront un efficacité accrue pour tuer les cellules et donc une plus haute Efficacité Biologique Relative que les photons de haute énergie. Pour étudier cet effet, il faut réduire le volume de matière considéré lors des évènements responsables du dépôt d'énergie afin d'atteindre des dimensions d'un ordre représentatif pour les cellules, microns ou même nanomètres. C'est pourquoi la partie de la physique des radiations dédiée à ce problème est appelée microdosimétrie. La seconde partie de ce travail est dédiée à une étude microdosimétrique théorique des ces sources de photons de basse énergie utilisant le concept de fonctions microdosimétriques pour des volumes de 1 µm et une analyse de cluster pour des volumes de l'ordre du nanomètre. Les deux types d'étude montrent que les photons de 20-30 keV sont effectivement plus efficaces radiobiologiquement que les photons de hautes énergie. Les résultats microdosimétriques donnent un rapport de yD relatif au Co-60 de 2.6 pour le Pd-103 et de 2.2 pour l'I-125, ce qui est concordant avec les valeurs expérimentales publiées par Wuu et al. (1996). L'analyse de cluster montre aussi que les électrons générés par les photons de 20-30 keV produisent plus de clusters d'ordre élevé que les électrons de 300 keV. L'ordre de cluster moyen pour des clusters de 10 nm est de 3.0 pour le 103Pd et de 3.3 pour l'I-125 comparé à 2.1 pour des électrons de 300keV. Dans ce cas, l'I-125 montre un ordre de cluster moyen plus élevé, ce qui est lié à une efficacité biologique potentiellement plus élevée. Ceci est expliqué par le fait que les photons de l'I-125 interagissent par effet Compton avec une probabilité de 51 %, cette probabilité tombe à 27 % dans le cas du Pd-103. Les interactions Compton génèrent un grand nombre d'électrons de très basse énergie qui déposent leur énergie très localement avec une très haute densité d'ionisations. D'autres études biologiques sont nécessaires pour déterminer quel volume est plus adapté et donc quel type d'étude reflète le mieux la réalité.
292

Improving political oversight in municipalities: examining the law and practice surrounding oversight by the council over the municipal Executive and the municipal administration

Williams, Elizabeth-Ann January 2012 (has links)
No description available.
293

Development Of A Stability Analysis Program For Block Type Quay Walls And Comparison Of Block Placing Methods

Nergiz, Cengiz 01 January 2010 (has links) (PDF)
Block type quay walls are commonly used as berthing structures both in Turkey and worldwide. In this study, stability analysis of block type quay wall is carried out using pseudo-static method. A computer program named QSAP (using Excel spreadsheet) has been developed for the design of block type quay walls. QSAP has been prepared based on the rules of Turkish Seismic Design Codes for Coastal Structures, 2008. Reliability of this program is verified by a comparative study of Derince Port block type quay wall, damaged in Marmara earthquake (1999), with manual solution and field measurements. A newly introduced placement methodology &ldquo / Knapsack&rdquo / is also studied with QSAP and the results are compared with the conventional placement method.
294

Measurement of the Top Quark Pair Production Cross Section and Simultaneous Extraction of the W Heavy Flavor Fraction at √s = 7 TeV with the ATLAS Detector at the LHC / Messung des Top-Quark-Paar Wirkungsquerschnitts und gleichzeitige Bestimmung des W Heavy Flavor Anteils bei √s = 7 TeV mit dem ATLAS Detektor am LHC

Roe, Adam 22 March 2012 (has links)
No description available.
295

Improving political oversight in municipalities: examining the law and practice surrounding oversight by the council over the municipal Executive and the municipal administration

Williams, Elizabeth-Ann January 2012 (has links)
No description available.
296

Kinect įrenginiui skirtų gestų atpažinimo algoritmų tyrimas / Research of gesture recognition algorithms dedicated for kinect device

Sinkus, Skirmantas 06 August 2014 (has links)
Microsoft Kinect įrenginys išleistas tik 2010 metais. Jis buvo skirtas Microsoft Xbox 360 vaizdo žaidimų konsolei, vėliau 2012 metais buvo pristatytas Kinect ir Windows personaliniams kompiuteriams. Taigi tai palyginus naujas įrenginys ir aktualus šiai dienai. Daugiausiai yra sukurta kompiuterinių žaidimų, kurie naudoja Microsoft Kinect įrenginį, bet šį įrenginį galima panaudoti daug plačiau ne tik žaidimuose, viena iš sričių tai sportas, konkrečiau treniruotės, kurias būtų galima atlikti namuose. Šiuo metu pasaulyje yra programinės įrangos, žaidimų, sportavimo programų, kuri leidžia kontroliuoti treniruočių eigą sekdama ar žmogus teisingai atlieka treniruotėms numatytus judesius. Kadangi Lietuvoje panašios programinės įrangos nėra, taigi reikia sukurti įrangą, kuri leistų Lietuvos treneriams kurti treniruotes orientuotas į šio įrenginio panaudojimą. Šio darbo pagrindinis tikslas yra atlikti Kinect įrenginiui skirtų gestų atpažinimo algoritmų tyrimą, kaip tiksliai jie gali atpažinti gestus ar gestą. Pagrindinis dėmesys skiriamas šiai problemai, taip pat keliami, bet netyrinėjami kriterijai kaip atpažinimo laikas, bei realizacijos sunkumas. Šiame darbe sukurta programa, judesius bei gestus atpažįsta naudojant Golden Section Search algoritmą. Algoritmas palygina du modelius ar šablonus, ir jei neranda atitikmens, tai pirmasis šablonas šiek tiek pasukamas ir lyginimo procesas paleidžiamas vėl, taipogi tam tikro kintamojo dėka galime keisti algoritmo tikslumą. Taipogi... [toliau žr. visą tekstą] / Microsoft Kinect device was released in 2010. It was designed for Microsoft Xbox 360 gaming console, later on in 2012 was presented Kinect device for Windows personal computer. So this device is new and current. Many games has been created for Microsoft Kinect device, but this device could be used not only in games, one of the areas where we can use it its sport, specific training, which can be performed at home. At this moment in world are huge variety of games, software, training programs which allows user to control training course by following a person properly perform training provided movements. Since in Lithuania similar software is not available, so it is necessary to create software that would allow Lithuania coaches create training focused on the use of this device. The main goal of this work is to perform research of the Kinect device gesture recognition algorithms to study exactly how they can recognize gestures or gesture. It will focus on this issue mainly, but does not address the criteria for recognition as the time and difficulty of realization. In this paper, a program that recognizes movements and gestures are using the Golden section search algorithm. Algorhithm compares the two models or templates, and if it can not find a match, this is the first template slightly rotated and comparison process is started again, also a certain variable helping, we can modify the algorithm accuracy. Also for comparison we can use Hidden Markov models algorhithm received... [to full text]
297

Locus of control and mode of delivery vaginal birth versus cesarean section : a report submitted in partial fulfillment ... Master of Science Parent-Child Nursing, Nurse-Midwifery ... /

McLellan, Priscilla Louise Green. January 1993 (has links)
Thesis (M.S.)--University of Michigan, 1993.
298

Locus of control and mode of delivery vaginal birth versus cesarean section : a report submitted in partial fulfillment ... Master of Science Parent-Child Nursing, Nurse-Midwifery ... /

McLellan, Priscilla Louise Green. January 1993 (has links)
Thesis (M.S.)--University of Michigan, 1993.
299

O impacto do risco de crédito sobre a diferença cross-section do retorno acionário brasileiro

Toledo, Eduardo Rietmann 31 May 2016 (has links)
Submitted by Eduardo Toledo (dudutol@hotmail.com) on 2016-09-15T14:15:58Z No. of bitstreams: 1 Dissertação Eduardo Rietmann Toledo - Final.pdf: 4612894 bytes, checksum: ab143894eec8b23502f2222a0b9a5a27 (MD5) / Approved for entry into archive by GILSON ROCHA MIRANDA (gilson.miranda@fgv.br) on 2016-09-21T14:12:18Z (GMT) No. of bitstreams: 1 Dissertação Eduardo Rietmann Toledo - Final.pdf: 4612894 bytes, checksum: ab143894eec8b23502f2222a0b9a5a27 (MD5) / Approved for entry into archive by Marcia Bacha (marcia.bacha@fgv.br) on 2016-09-23T12:48:52Z (GMT) No. of bitstreams: 1 Dissertação Eduardo Rietmann Toledo - Final.pdf: 4612894 bytes, checksum: ab143894eec8b23502f2222a0b9a5a27 (MD5) / Made available in DSpace on 2016-09-23T12:49:08Z (GMT). No. of bitstreams: 1 Dissertação Eduardo Rietmann Toledo - Final.pdf: 4612894 bytes, checksum: ab143894eec8b23502f2222a0b9a5a27 (MD5) Previous issue date: 2016-05-31 / The aim of this study is to assess the impact of credit risk in the Brazilian stock cross-section return, and evaluate if a strategy based on this feature is able to generate positive and significant alpha. To measure credit risk, credit ratings were used assigned to Brazilian companies by the american agency Standard and Poors in the period between 2009 and 2014. First we divided ali firms in portfolios according to their credit risk and after we analyzed monthly returns of their stocks. Empirically, we find an evidence that the credit risk has a positive correlation in stock returns. However, as the strategy to operate based on credit risk was not able to generate significant alpha, it was not possible to statistically validate this effect on return. / O objetivo deste estudo é verificar o impacto do risco de crédito no retorno cross-section acionário brasileiro e avaliar se uma estratégia baseada nesta característica é capaz de gerar alfa positivo e significativo. Para mensurar o risco de crédito, foram utilizadas as notas de crédito atribuídas às empresas brasileiras pela agência americana Standard and Poors no período entre 2009 e 2014. Dividimos as empresas em portfolios de acordo com seu risco de crédito e analisamos os retornos mensais de suas ações. Empiricamente, encontramos indícios que o risco de crédito possui uma correlação positiva com o retorno acionário. No entanto, como a estratégia para operar baseada no risco de crédito não foi capaz de gerar alfa significativo, não foi possível validar estatisticamente este efeito sobre o retorno.
300

Structures spatiales déployables constituées de mètres rubans : analyse et implémentation de modèles de poutre à section flexible / Deployable space structures made up of tape springs : analysis and implementation of rod models with flexible cross-section

Martin, Maverick 08 December 2017 (has links)
Les mètres rubans sont utilisés comme dispositif de déploiement car ils sont légers, compacts, se déploient de manière autonome et ont une capacité d'auto-blocage en position déployée. Ces structures élancées de forme cylindrique présentent un comportement complexe avec formation de plis localisés. Leur modélisation est donc difficile : bien que des modèles de poutre à section flexible (RFleXS) aient été développés. Les travaux réalisés consistent à développer des outils numériques d'aide au dimensionnement de structures déployées par des rubans. Un modèle RFleXS adimensionné dédié aux rubans peu profonds est introduit et analysé, mettant en évidence des liens avec le modèle de barre d'Ericksen régularisé. Ces liens expliquent la formation de plis et caractérisent les trois zones constitutives d'un pli. On détermine de façon analytique le nombre et la position des points de bifurcation des branches de solution obtenues pour un essai de flexion pure d'un ruban. Un enrichissement de la cinématique de section est intégré dans les modèles RFleXS. Les simulations de flexion de ruban montrent alors une bonne corrélation avec les modèles de coque. Une nouvelle formulation des modèles RFleXS est implémentée et conduisant au développement de deux outils numériques : un code de calcul par éléments finis complet et un élément à deux noeuds intégré dans un code commercial. Des essais de flexion réalisés sur des rubans composites viennent compléter ces travaux afin de confronter les simulations numériques à des essais réels. Bien que des écarts soient observés, le comportement global du ruban est bien retranscrit par les modèles de poutre à section flexible. / Due to their lightness, compactness, their autonomous deployment and their ability to self-locking while deployed, tape-springs are considered to deploy structures. These slender and cylindrical structures highlight a complex behaviour because of the formation of localised folds. Tape-springs are then difficult to model but a rod model with flexible cross-section (RFleXS) has been developed in order to characterise the tape-spring behaviour.The purpose of this PhD was to develop numerical tools dedicated to design structures deployed by tape-spings. A dimensionless form of the RFleXS model dedicated to shallow tape spring has been developed and links with a regularised Ericksen's bar have been made. These links help to explain folds creation and to determine characteristics of the three constitutive areas of a fold. Analysis of the dimensionless model leads to determine the finite number and the position of bifurcation points for the pure bending of a tape-spring. The cross-section kinematic is enriched; simulations of bending tests then show a good correlation with shell models. A new implementation of RFleXS models is introduced, leading to the creation of two numerical tools: a full finite element software and a one-dimensional element with two nodes incorporated in Abaqus. Some bending experiments have been performed in order to compare simulations with measured data. Even if discrepancies are observed, these comparisons show that the tape-spring overall behaviour is well predicted by rod models with flexible cross-section.

Page generated in 0.0812 seconds