• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 224
  • Tagged with
  • 225
  • 225
  • 225
  • 203
  • 202
  • 188
  • 188
  • 167
  • 133
  • 63
  • 58
  • 48
  • 45
  • 40
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Análise da qualidade de energia em sistemas de distribuição através de medição e fluxo de carga harmônico trifásico

BRANCHE, Marcos Nascimento 02 October 2005 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2012-04-12T22:38:57Z No. of bitstreams: 2 Dissertacao_AnaliseQualidadeEnergia.pdf: 1082007 bytes, checksum: 59f5852a3f1d4bc475b56aa78d8958d9 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Approved for entry into archive by Edisangela Bastos(edisangela@ufpa.br) on 2012-04-12T22:39:43Z (GMT) No. of bitstreams: 2 Dissertacao_AnaliseQualidadeEnergia.pdf: 1082007 bytes, checksum: 59f5852a3f1d4bc475b56aa78d8958d9 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2012-04-12T22:39:43Z (GMT). No. of bitstreams: 2 Dissertacao_AnaliseQualidadeEnergia.pdf: 1082007 bytes, checksum: 59f5852a3f1d4bc475b56aa78d8958d9 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2005 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Este trabalho apresenta uma análise da qualidade de energia realizado em um sistema real de distribuição de energia elétrica, a partir das diferentes classes de consumo atendida pela concessionária. O estudo foi realizado em duas etapas, sendo a primeira através de medições realizadas no secundário de transformadores da rede de distribuição que atende ao sistema da CEA (Companhia de Eletricidade do Amapá), previamente classificados por classe de atendimento sendo, classe comercial, residencial e mista. Através do estudo torna-se possível a identificação e a caracterização de fontes geradoras de harmônicos no sistema, possibilitando assim a análise do nível de injeção de harmônicos em sua rede de distribuição, bem como a avaliação dos impactos que essas fontes distribuídas de geração harmônica podem provocar na qualidade de energia fornecida pela concessionária. A etapa final do estudo apresenta o uso de um fluxo de carga harmônico trifásico, onde a partir do perfil harmônico obtido no estudo, é feita uma avaliação de forma global do sistema. / This work presents an analysis about the power quality, carried out in a real electrical energy distribution grid, considering different customers groups, located in the low voltage grid. The study was made in two steps. The first one through measurements registered in the transformers of the distribution grid supplied by CEA – Amapá’s Electricity Company, previously classified in groups as: commercial group, residential group and home-and-commercial group, identifying and characterizing the generators sources of harmonics generation in the system, making possible, this way, an analysis of the harmonic injection level in the distribution grid as well as the impacts these distribution sources of harmonic generation can provoke in the power quality offered by the CEA utility. The last stage of the study presents the use of a threephase harmonic load flow, where, considering the harmonic profile found out through the measurements carried out, a global evaluation of the system is provided.
22

Estudo dos efeitos das descargas atmosféricas nos índices de desempenho da Subestação de Vila do Conde

PEREIRA, Jorge Luiz Moreira 11 September 2014 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2015-02-05T15:58:26Z No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_EstudoEfeitosDescargas.pdf: 3260439 bytes, checksum: fa17a2a9de4c6f3de1135b0c04e86b2e (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2015-02-06T13:58:24Z (GMT) No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_EstudoEfeitosDescargas.pdf: 3260439 bytes, checksum: fa17a2a9de4c6f3de1135b0c04e86b2e (MD5) / Made available in DSpace on 2015-02-06T13:58:24Z (GMT). No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_EstudoEfeitosDescargas.pdf: 3260439 bytes, checksum: fa17a2a9de4c6f3de1135b0c04e86b2e (MD5) Previous issue date: 2014 / Este trabalho tem como objetivo apresentar os efeitos de descargas atmosféricas nos índices de desempenho na SE VDC (subestação de Vila do Conde), situada na região norte, no estado do Pará, no período de 2005 a 2013, estabelecendo a relação entre as informações meteorológicas cedidas pelo SIPAM e dados fornecidos pelo centro de operações da Eletronorte de forma a realizar e determinar os efeitos nocivos das descargas atmosféricas, os quais são responsáveis pela intensificação de interrupções no fornecimento de energia elétrica. A análise é restrita à área de atuação da Eletronorte (subestação de Vila do Conde) que tem grande parte de suas Linhas de Transmissão de energia instaladas no Norte do Brasil. O estudo desenvolvido evidência os desligamentos por descargas atmosféricas na linha de transmissão VDC/CASTANHAL de 230 KV e no disjuntor de 500 KV VCDJ7-08.Os resultados demonstram que a incidência de um raio pode causar surtos diretos e indiretos em linhas de transmissão e subestações de alta potência. Neste contexto justifica o estudo de formas eficientes de prevenção, sendo uma das finalidades desta obra, que tem como objetivo geral apresentar informações relativas aos efeitos produzidos pela ação de descargas atmosféricas em subestações do setor elétrico quanto à qualidade de energia, em especial na SE VDC – Sistema Eletrobrás-Eletronorte. / This work aims to present the effects of lightning performance indexes in VDC (substation of Vila do Conde), located in the northern region, in the State of Pará, in the period from 2005 to 2013, establishing the relationship between the weather information provided by the SIPAM and data provided by the center of operations for Eletronorte in order to perform and determine the harmful effects of atmospheric discharges, which are responsible for the intensification of interruptions in the supply of electricity.The analysis is restricted to the area of expertise of Eletronorte (substation of Vila do Conde) which has much of its power transmission Lines installed in northern Brazil. The results show that the incidence of lightning can cause direct and indirect surges in transmission lines and substations of high power. In this context justifies the study of efficient forms of prevention, being one of the purposes of this work, which aims to provide general information concerning the effects produced by the action of atmospheric discharges in substations of the power sector as the quality of energy, in particular in the VDC – Eletrobrás System-Eletronorte.
23

Análise estática e dinâmica de parques eólicos mistos compostos por aerogeradores de velocidade fixa e variável

SILVA, Helleson Jorthan Brito da 21 November 2014 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-02-21T18:11:43Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseEstatisticaDinamica.pdf: 7360019 bytes, checksum: 4fdab49e9f84f9507cb815892bccb1e4 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-27T13:37:01Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseEstatisticaDinamica.pdf: 7360019 bytes, checksum: 4fdab49e9f84f9507cb815892bccb1e4 (MD5) / Made available in DSpace on 2017-03-27T13:37:01Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseEstatisticaDinamica.pdf: 7360019 bytes, checksum: 4fdab49e9f84f9507cb815892bccb1e4 (MD5) Previous issue date: 2014-11-21 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Os sistemas eólicos de geração de energia elétrica se apresentam como uma solução adequada para o atendimento aos requisitos técnicos, econômicos, ambientais, sociais e governamentais, por isso eles têm sido largamente usados em diversos países. Dentre as tecnologias de aerogeradores disponíveis, os sistemas eólicos a velocidade fixa com geradores de indução em gaiola de esquilo e a velocidade variável com geradores de indução duplamente alimentados são os mais populares. Com o aumento dos níveis de penetração eólica na rede elétrica e devido às desvantagens tecnológicas dos aerogeradores com gerador de indução em gaiola, uma tendência em substituir esse conceito pelo aerogerador com gerador de indução duplamente alimentado na construção de novos parques eólicos é observada. No caso de usinas eólicas já instaladas, por razões econômicas, o processo de modernização gradativo é mais conveniente. Embora os dois sistemas eólicos sejam bem conhecidos, mas pouco se sabe sobre a operação conjunta de ambos. Dessa forma, o presente artigo propõe um estudo para avaliar os impactos ocorridos pela integração de um parque eólico misto na rede elétrica, com geradores de indução em gaiola de esquilo e duplamente alimentados. Aspectos relacionados à estabilidade de velocidade sob falta e curtas variações de vento e à estabilidade de tensão são analisados. A interação entre as tecnologias também é objeto de estudo. Casos com diferentes níveis de penetração dos sistemas eólicos são considerados, representando a substituição gradativa de parte dos aerogeradores de conceito antigo por outros do conceito mais moderno. Os resultados obtidos mostram que as características do gerador de indução duplamente alimentado aliadas com a redução da injeção de potência dos sistemas eólicos a velocidade fixa melhoram o comportamento do parque eólico, sugerindo que a operação conjunta dos aerogeradores pode ser uma solução de boa relação custo-benefício. / The wind electric power generation systems are presented as an appropriate solution to meet the technical, economic, environmental, social and governmental requirements, therefore they have been largely used in several countries. Among the wind turbines technologies available, the speed-fixed with squirrel cage induction generator and variable-speed with doubly fed induction generator wind systems are the most popular. With increasing of the wind penetration levels in electrical grid and due the technologic drawbacks of the wind turbine with cage induction generator, a tend to replace this concept by wind turbine with doubly fed induction generator in the construction of new wind farms is seen. In the case of wind plant installed already, for economic reasons, the gradative modernization process is more convenient. Although both wind systems are well known, but about the combined operation of them is known a little. Thus, the present paper proposes a study to evaluate the impacts occurred by integration of a mixed wind farm in the electrical grid, with squirrel cage and doubly fed induction generators. Aspects related to transient stability under fault and short wind variations and voltage stability are analyzed. The interactions between the technologies are also object of study. Cases with different penetration levels of the wind systems are considered, representing the gradative replace of part of the old concept wind turbine by others of the concept more modern. The results obtained show that the characteristics of the doubly fed induction generator allied with the reduction of the power injection of the fixed-speed wind systems improve the wind farm behavior, suggesting that the combined operation of the wind turbines could be a more costeffective solution.
24

O estudo da influência do ciclo de partidas e paradas no estator de geradores síncronos

SANTOS, Renato Lelio da Silva 28 February 2011 (has links)
Submitted by Samira Prince (prince@ufpa.br) on 2012-05-17T12:20:34Z No. of bitstreams: 2 Dissertação_EstudoInfluenciaCiclo.pdf: 2246492 bytes, checksum: 3d387c0cc322c7fdea43f2d09764e93f (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Approved for entry into archive by Samira Prince(prince@ufpa.br) on 2012-05-17T12:38:11Z (GMT) No. of bitstreams: 2 Dissertação_EstudoInfluenciaCiclo.pdf: 2246492 bytes, checksum: 3d387c0cc322c7fdea43f2d09764e93f (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2012-05-17T12:38:11Z (GMT). No. of bitstreams: 2 Dissertação_EstudoInfluenciaCiclo.pdf: 2246492 bytes, checksum: 3d387c0cc322c7fdea43f2d09764e93f (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2011 / Os geradores síncronos se submetem a diferentes situações de paradas para desligamento forçado, desligamento por condições externas, desligamento programado para manutenção corretiva e preventiva. As diferentes variações de temperatura em que se submete o gerador síncrono, precisamente, ao seu estator, afeta o seu isolamento, que não acompanha essas constantes variações, devido ter um coeficiente de dilatação diferente. No presente trabalho busca-se identificar uma tendência de progressão do envelhecimento do isolamento de seus enrolamentos estatóricos em máquinas que sofrem repetitivas partidas e paradas e que ficam com sua reserva de energia desligada por muitas horas. O estudo foi aplicado nos cinco geradores síncronos da usina hidrelétrica de Balbina, pertencente ao grupo Eletrobrás, que apresenta tal problema. Esse estudo vem comprovar os ensaios de análise de descargas parciais dos geradores síncronos realizados periodicamente para diagnosticar problemas nos seus enrolamentos estatóricos que apresentam diferentes magnitudes e confirmar a hipótese de que máquinas que apresentam maiores magnitudes de descargas parciais em seus estatores são as que se submetem maiores quantidades de partidas e paradas e horas com energia de reserva desligada. / The synchronous generators under different stops situations forced shutdown, shutdown by external conditions, scheduled for corrective and preventive maintenance. The different variations in temperature that undergoes a synchronous generator, exactly to its stator affects its isolation, which does not follow these constant changes, due to have a different coefficient of expansion. In the present work has identified a trend of progressive aging of the insulation of stator windings in their machines that suffer repetitive starting and stopping and staying with his reserve power off for several hours. The study was implemented in five synchronous generators Balbina hydroelectric of Eletrobras group, which presents such a problem. This study confirms for the tests of analysis of partial discharge of the synchronous generators performed periodically to diagnose problems in their stator windings, with different magnitudes and identify the thesis that machines that have larger magnitudes of partial discharges off in their stators are undergoing more amounts of starting and stopping and staying with the most hours with standby power off.
25

Influências de famílias wavelets e suas ordens no desempenho de um localizador de faltas em linhas aéreas de transmissão de energia elétrica

ARAUJO, Maryson da Silva 04 November 2011 (has links)
Submitted by Samira Prince (prince@ufpa.br) on 2012-08-28T14:54:01Z No. of bitstreams: 2 Dissertacao_InfluenciasFamiliasWavelets.pdf: 13148962 bytes, checksum: 8cc99d80429abe5dc9a0cdac2447d733 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Approved for entry into archive by Samira Prince(prince@ufpa.br) on 2012-08-28T14:54:38Z (GMT) No. of bitstreams: 2 Dissertacao_InfluenciasFamiliasWavelets.pdf: 13148962 bytes, checksum: 8cc99d80429abe5dc9a0cdac2447d733 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2012-08-28T14:54:38Z (GMT). No. of bitstreams: 2 Dissertacao_InfluenciasFamiliasWavelets.pdf: 13148962 bytes, checksum: 8cc99d80429abe5dc9a0cdac2447d733 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2011 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Essa dissertação tem por objetivo analisar a influência de famílias wavelets e suas ordens no desempenho de um algoritmo de localização de faltas a partir das ondas viajantes de dois terminais de uma linha de transmissão aérea. Tornou-se objetivo secundário a modelagem de um sistema elétrico de potência (SEP) para obtenção de um universo de faltas que validassem o localizador. Para isso, parte de um SEP da Eletrobrás-Eletronorte em 500/230 kV foi modelado no Alternative Transient Program (ATP) utilizando-se parâmetros reais. A Transformada Wavelet, via análise multiresolução (AMR), é empregada valendo-se de sua característica de localização temporal, permitindo caracterizações precisas de instantes de transitórios eletromagnéticos ocasionados por faltas, as quais geram ondas que ao se propagarem em direção aos terminais da linha contêm os tempos de propagação destas do local do defeito a tais terminais e podem ser convenientemente extraídos por tal transformada. Pela metodologia adotada no algoritmo, a diferença entre esses tempos determina com boa exatidão o local de ocorrência da falta sobre a linha. Entretanto, um dos agentes variantes do erro nessa estimação é a escolha da Wavelet usada na AMR dos sinais, sendo, portanto, a avaliação dessa escolha sobre o erro, objetivo principal do trabalho, justificada pela ainda inexistente fundamentação científica que garanta a escolha de uma wavelet ótima a uma certa aplicação. Dentre um leque de Wavelets discretas, obtiveram-se resultados adequados para 16 delas, havendo erros máximos inferiores aos 250 metros estipulados para a precisão. Duas Wavelets, a Db15 e a Sym17, sobressaíram-se ao errarem, respectivamente, 3,5 e 1,1 vezes menos que as demais. A metodologia empregada consta da: exportação dos dados das faltas do ATP para o MATLAB®; aplicação da transformação modal de Clarke; decomposição dos modos alfa e síntese dos níveis 1 de detalhes via AMR; cálculo de suas máximas magnitudes e determinação dos índices temporais; e por fim, a teoria das ondas viajantes equaciona e estima o local do defeito sobre a LT, sendo tudo isso programado no MATLAB e os erros de localização analisados estatisticamente no Microsoft Excell®. Ao final elaborou-se ainda uma GUI (Guide User Interface) para a Interface Homem-Máquina (IHM) do localizador, servindo também para análises gráficas de qualquer das contingências aplicadas ao SEP. Os resultados alcançados demonstram uma otimização de performance em razão da escolha da wavelet mais adequada ao algoritmo e norteiam para uma aplicação prática do localizador. / This dissertation objective to analyze the influence of wavelets families and their orders in the performance of a fault location algorithm through the traveling waves from two ends of an overhead transmission line. Then, a secondary objective is the modelling of an electric power system (EPS) to obtaining of a fault’s universe to validate the algorithm. For that, part of an EPS of the Eletrobrás-Eletronorte on 500/230 kV was modeled in Alternative Transient Program (ATP) using real parameters. The Wavelet Transform, through multiresolution analysis (MRA), it’s used because its time domain localization characteristic to allow characterizations of electromagnetic transitory moments caused by contingencies. The waves generated by faults traveling towards the line’s terminals containing the wave propagation times from defect point at the terminals and these times can be conveniently extracted for such transformed. By means of the methodology adopted in the algorithm, the difference between those times determines the fault occurrence place on the line with good accuracy. However, one of the error variant agents in the estimation it’s the selection of the wavelet used in MRA of the signals, therefore the evaluation of that choice upon those errors, the main objective of this work, it’s justified for the still inexistent scientific bases that assure the choice of a great wavelet to a certain application. Among a diversity of discrete wavelets, appropriated results were obtained for 16 of them with maximum errors smaller than 250 meters, stipulated precision adopted. Two wavelets, Db15 and Sym17, were more exact than the others, respectively, 3.5 and 1.1 times. The methodology to get those results consists of the: export of the fault data files from ATP for MATLAB®; application of the Clarke’s modal transformation of voltages; decomposition of alpha modes and synthesis of the levels 1 of details through AMR; calculation of their maximum magnitudes and time indexes determination; finally, the traveling waves theory is used to formulate the estimate equation of the contingency place on the line. All methodology was programmed in MATLAB and the errors’ statistical analysis was made in Microsoft Excell®. At the end, a GUI (Guide User Interface) for (Human Machine Interface) HMI of locator was elaborated, which is also a graphical analysis interface, no matter which the contingency applied to the EPS. The attained results demonstrate an improved performance in reason of the most appropriate wavelet selection to the algorithm and they suggest a practical application of the locator.
26

Desenvolvimento e implantação de um sistema para monitoração do desempenho energético de edificações

MANITO, Alex Renan Arrifano 11 October 2012 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2013-03-20T21:01:10Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_DesenvolvimentoImplatacaoSistema.pdf: 3715364 bytes, checksum: be1eb00f45ddf8de68f0e9332886c68d (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-03-27T17:28:20Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_DesenvolvimentoImplatacaoSistema.pdf: 3715364 bytes, checksum: be1eb00f45ddf8de68f0e9332886c68d (MD5) / Made available in DSpace on 2013-03-27T17:28:20Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_DesenvolvimentoImplatacaoSistema.pdf: 3715364 bytes, checksum: be1eb00f45ddf8de68f0e9332886c68d (MD5) Previous issue date: 2012 / Este trabalho apresenta as estratégias e convenções adotadas, assim como os módulos em funcionamento, do sistema de monitoração desenvolvido e que está sendo implantado na edificação do Grupo de Estudos e Desenvolvimento de Alternativas Energéticas (GEDAE), denominada de Laboratório de Energias Renováveis e Eficiência Energética, com o objetivo de monitorar principalmente as variáveis climáticas e aquelas referentes à geração e ao consumo da edificação. Com esse sistema, objetiva-se a criação de uma base de dados unificada, sincronizada e de fácil acesso aos usuários da edificação, bem como a criação de ferramentas personalizáveis pelos usuários para a análise dos dados coletados e com possibilidade de expansão para a inserção de novas grandezas de interesse, facilitando, desta forma, estudos a respeito do desempenho da edificação quanto ao seu consumo de energia elétrica, seus sistemas de produção de eletricidade e condições de conforto ambiental no interior da edificação, além de permitir a análise das estratégias adotadas na edificação. Espera-se que os dados coletados possam também exercer a função de divulgação de estratégias de eficiência energética em edificações por meio da publicação de alguns resultados na internet em uma página dinâmica para tal fim. / This work presents the strategies and standards adopted, as well as the operating modules, of the monitoring system developed and which is currently being implemented in the building of the Grupo de Estudos e Desenvolvimento de Alternativas Energéticas (GEDAE), called the Laboratory of Renewable Energy and Energy Efficiency, aiming to monitor mainly climatic parameters and those related to the electricity generation and the consumption of the building. The system’s goal is the creation of a unified and synchronized database, of easy access to the users of the building, as well as the development of customizable tools for the acquired data analysis with the possibility of being expanded to accept new variables of interest, facilitating studies concerning the performance of the building when it comes to its energy consumption, energy generation systems and environmental comfort conditions, and also enabling the evaluation of the strategies adopted in the building. It is expected that the data collected can be used as a way of disseminating strategies for energy efficiency in buildings as well, through the publishing of some of the results on the internet in a dynamic page for that purpose.
27

Desenvolvimento de framework para análise e simulação dinâmica de sistemas elétricos de potência

SENA, José Adolfo da Silva 18 January 2013 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2013-05-03T22:25:35Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_DesenvolvimentoFrameworkAnalise.pdf: 4581009 bytes, checksum: 6edb3a474cd7c7d7f271c175bbd47f06 (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-05-06T13:57:42Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_DesenvolvimentoFrameworkAnalise.pdf: 4581009 bytes, checksum: 6edb3a474cd7c7d7f271c175bbd47f06 (MD5) / Made available in DSpace on 2013-05-06T13:57:42Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_DesenvolvimentoFrameworkAnalise.pdf: 4581009 bytes, checksum: 6edb3a474cd7c7d7f271c175bbd47f06 (MD5) Previous issue date: 2013 / Esta tese apresenta uma metodologia flexível orientada a objetos (OO) para a aplicação no projeto e implementação de sistemas de software utilizados na realização de estudos dinâmicos de sistemas elétricos de grande porte. A metodologia OO proposta objetiva tornar mais simples o desenvolvimento, a atualização e a manutenção de complexos sistemas de software para estudos de transitórios eletromecânicos em sistemas elétricos de potência. Os requisitos de usuário são mapeados para um conjunto de classes básicas, as quais são usadas para efetuar a modelagem de dispositivos dinâmicos tais como geradores elétricos. Para avaliação da metodologia foram realizados dois estudos de casos. No primeiro estudo caso o Framework foi aplicado na simulação das unidades geradoras da Usina Hidrelétrica de Tucuruí. Os resultados da simulação foram comparados com medições obtidos em ensaios no campo e mostrou a boa performance do Framework na reprodução dos fenômenos eletromecânicos desta usina de grande porte. No segundo estudo de caso, por outro lado, o Framework foi aplicado na modelagem de um sistema de geração fotovoltaico (PV) com seu sistema de Rastreamento da Potência Máxima (MPPT). O controle MPPT foi implementado usando técnicas digitais. Os resultados das simulações demonstram a performance do Framework na modelagem do sistema de controle de corrente, assim como no controle MPPT, dos sistemas de geração PV. / This thesis presents a flexible Object Oriented (OO) methodology for the design and implementation of simulation software system used to perform dynamic studies of large electrical power systems. The proposed OO methodology aims at make easier the development, upgrade and maintenance of complex software systems. The user's requirements are mapped to set base classes which are atomic classes to perform the modeling of the dynamic devices such as electrical generators. In order to evaluate the methodology, a simulation software system was developed using the OO modeling. In order to evaluate the Framework performance, two study cases were carried out. The first one apply the Framework on the modeling and simulation of generation units at Tucuruí Power Plant. The simulation results were comparated to data measurements from field tests and shown the good performance of the Framework on reproducing electromechanical phenomena of this large Power Plant. In the second study, by its turn, the Framework was applied to the modeling of a Photovoltaic (PV) generation system, along with its Maximum Power Tracking (MPPT). The MPPT control was implemented using digital techniques. The simulation results show the good performance of the Framework on modeling the current as well as MPPT control of PV generations systems.
28

Análise do enxofre corrosivo em óleo mineral isolante e remoção do dibenzil dissulfeto com nanotubos de carbono baseados em matriz metálica

SARAIVA, Augusto Cesar Fonseca 07 May 2012 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2014-01-13T19:07:46Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_AnaliseEnxofreCorrosivo.pdf: 5261345 bytes, checksum: d394934b8edcf92029d079a04f821905 (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2014-01-14T16:03:22Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_AnaliseEnxofreCorrosivo.pdf: 5261345 bytes, checksum: d394934b8edcf92029d079a04f821905 (MD5) / Made available in DSpace on 2014-01-14T16:03:22Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_AnaliseEnxofreCorrosivo.pdf: 5261345 bytes, checksum: d394934b8edcf92029d079a04f821905 (MD5) Previous issue date: 2012 / Falhas inesperadas em transformadores levaram a identificação da formação de sulfeto de cobre, depositado sobre os condutores, avaliando-se da presença qualitativa de enxofre corrosivo resultando na alteração da norma brasileira ABNT NBR 10505, que avalia a presença de enxofre corrosivo em óleo mineral, alterando-se o tempo e a temperatura de ensaio para 150 °C por 48 horas. Realizando-se a especiação química de compostos organosulfurados via cromatografia gasosa acoplada a espectrometria de massas, onde foram encontrados 13 compostos sulfurados no óleo Nynas e 9 compostos no óleo da Petrobras, sendo o dibenzil dissulfeto (DBDS) o de maior concentração, encontrado apenas no óleo Nynas. Para realizar a determinação da presença do DBDS em óleo mineral isolante foi desenvolvido um método através de cromatografia gasosa acoplada a espectrometria de massas, e por este método foi possível quantificar o teor de DBDS em amostras de OMI oriundas de transformadores de potência. Foi avaliado o processo de passivação do cobre por benzotriazol e tolutriazol, utilizados como aditivos anticorrosivos no núcleo dos equipamentos elétricos, verificando-se que o efeito da adição agente de passivação torna-se ineficaz com o passar do tempo. A solução para a remoção de DBDS em óleo mineral foi a utilização de nanotubo de carbono baseado em matriz metálica (NTC/Al) como agente de remoção do DBDS. Verificou-se que o agente de adsorção foi capaz de efetuar a remoção total do DBDS do OMI até um volume de 4000 mL de óleo contaminado com DBDS. / Unexpected failures in transformers led to the identification of copper sulphide formation, deposited on the conductors. The qualitative presence evaluation of corrosive sulfur in insulating mineral oil, led to a change in the Brazilian standards ABNT NBR 10505, which assesses the presence of corrosive sulfur in mineral oil, change in the time and test temperature to 150 °C / 48 hours. Performing the chemical speciation of organosulfur compounds (by gas chromatography coupled to mass spectrometry), were found 13 compounds in the Nynas oil and 9 compounds in the Petrobras oil. DBDS, which was found only in the Nynas oil, and it was the compound with the highest concentration. To perform the determination of the presence of DBDS in insulating mineral oil, a method by gas chromatography coupled to mass spectrometry was developed, and it was possible to quantify the amount of DBDS in insulating mineral oil samples derived from the power transformer. The passivation process by tolutriazol and benzotriazol, used as anticorrosive additives in the core of electrical equipament, was evaluated; after a while the effect of the addition of passivating agent becomes ineffective with time. The solution for the remotionl of DBDS from mineral oil was realized by using carbon nanotube reinforced by metallic matrix as agent to remove the DBDS. It was found that the adsorption agent was able to realize the complete DBDS remotion from insulating mineral oil up to a volume of 4000 mL (oil contaminated with DBD).
29

Laboratório remoto para ensino de eficiência energética em um sistema de bombeamento de água

LOUREIRO, Igor Bittencourt 09 November 2009 (has links)
Submitted by Irvana Coutinho (irvana@ufpa.br) on 2011-03-30T12:50:49Z No. of bitstreams: 2 LOUREIRO, Igor Bittencourt PPGEngenharia Elétrica.pdf: 1727098 bytes, checksum: 5850972f48738c7ed3cbe14edd35ba89 (MD5) license_rdf: 22876 bytes, checksum: 0a4e855daae7a181424315bc63e71991 (MD5) / Made available in DSpace on 2011-03-30T12:50:49Z (GMT). No. of bitstreams: 2 LOUREIRO, Igor Bittencourt PPGEngenharia Elétrica.pdf: 1727098 bytes, checksum: 5850972f48738c7ed3cbe14edd35ba89 (MD5) license_rdf: 22876 bytes, checksum: 0a4e855daae7a181424315bc63e71991 (MD5) Previous issue date: 2009 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / A utilização racional da energia elétrica é um tema bastante discutido na atualidade. Uma das principais preocupações é com o setor industrial brasileiro, o qual é responsável pela maior parte do consumo desse tipo de energia, devido à utilização de sistemas motrizes. Aliado a esse fato, a falta de uma abordagem adequada ao ensino de eficiência energética e conservação de energia, em muitos cursos de Engenharia das universidades brasileiras, contribui para o aumento do desperdício de energia elétrica. Neste sentido, este trabalho apresenta um laboratório remoto voltado a realização de ensaios de eficiência energética em um sistema motriz de bombeamento d’água. Para isto, foi desenvolvido um software que permite acionar e monitorar o protótipo de bombeamento d’água pertencente ao LAMOTRIZ da Universidade Federal do Pará. Ainda, foi elaborado um ensaio piloto para testar a experimentação remota com alunos de graduação e pós-graduação da referida universidade e foi realizada uma avaliação desta experimentação pelos referidos alunos. / The rational use of electric energy is a subject much discussed at present. A major concern is with the Brazilian industrial sector, which is responsible for most of the consumption of such energy, due to the use of motor systems. Allied to this fact, the lack of an appropriate approach to teaching energy efficiency and energy conservation in many Engineering courses in Brazilian universities, contributes to the increase in electricity waste. In this sense, this work presents a remote laboratory aimed at testing the energy efficiency in a system driving water pumping. For this, we developed a software to monitor and trigger the prototype water pumping LAMOTRIZ belonging to the Federal University of Pará. Still, we designed a pilot trial to test the remote experimentation with undergraduate and postgraduate students of that University and conducted an evaluation of this trial by those students.
30

Avaliação de estratégias de controle de potência reativa de aerogeradores síncronos em redes elétricas

NASCIMENTO, André Cavalcante do 11 2009 (has links)
Submitted by Irvana Coutinho (irvana@ufpa.br) on 2011-03-30T14:08:53Z No. of bitstreams: 2 NASCIMENTO, Andre Cavalcante do PPGEngenharia Elétrica tese.pdf: 2273415 bytes, checksum: 499dfcfe91476179f87605f7f44906d5 (MD5) license_rdf: 22876 bytes, checksum: 0a4e855daae7a181424315bc63e71991 (MD5) / Made available in DSpace on 2011-03-30T14:08:53Z (GMT). No. of bitstreams: 2 NASCIMENTO, Andre Cavalcante do PPGEngenharia Elétrica tese.pdf: 2273415 bytes, checksum: 499dfcfe91476179f87605f7f44906d5 (MD5) license_rdf: 22876 bytes, checksum: 0a4e855daae7a181424315bc63e71991 (MD5) Previous issue date: 2009 / No presente trabalho é avaliada uma metodologia de injeção de potência reativa em redes elétricas durante afundamentos de tensão provocados por curto-circuito, em parques eólicos interligados, adotada em alguns países com maturidade tecnológica na produção de energia eólica. Nos estudos desenvolvidos, foi utilizado o aerogerador síncrono a imã permanente com conversor pleno em função da grande controlabilidade do conversor interligado à rede e por possuir elevada capacidade de fornecimento de potência reativa, comparada a outras tecnologias de aerogeradores. No Brasil, os requisitos de interligação de parques eólicos as redes elétricas, definido pelo Operador Nacional do Sistema, ainda não estipula a necessidade de adoção de tal metodologia durante defeitos na rede elétrica, apenas especifica a curva de capacidade de afundamentos de tensão que os aerogeradores devem seguir para evitar o desligamento frente a afundamentos de tensão. Os critérios de proteção do aerogerador síncrono são avaliados a partir de simulações de curto-circuito em uma rede de teste adotando-se os requisitos do Brasil, sem injeção de potência reativa, sendo comparados com o de outros países que adotam curvas de injeção de potência reativa. / In the present work a methodology of reactive power injection in electric grids during voltage dips provoked by short-circuit, in connected wind farms, adopted at some countries with technological maturity in the production of wind energy in the world is evaluated. In the developed studies, the direct drive synchronous wind generator was used with full converter due to the high controllability of the converter connected to the electric grid and for possessing high capacity of reactive power supply, compared to other wind generators technologies. In Brazil, the grid code to connect wind farms to the electric grids, defined by the National Operator of the Electrical System, doesn't stipulate yet the need of adoption of such methodology during faults in the electric grid. It just specifies the ride through apability curve for voltage dips that the wind generators should follow to avoid the trip of the undervoltage relay. Criteria of the synchronous wind generators protection are evaluated starting from short-circuit simulations in a test grid with adoption of the Brazilian grid code, without reactive power injection, being compared with those of other countries that adopt reactive power injection curves. / IFPA - Instituto Federal de Educação, Ciência e Tecnologia do Pará

Page generated in 0.1009 seconds