• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 184
  • 51
  • 30
  • 22
  • 10
  • 8
  • 7
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 383
  • 383
  • 50
  • 43
  • 41
  • 40
  • 37
  • 37
  • 37
  • 35
  • 30
  • 26
  • 26
  • 23
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Detection and drug delivery from superhydrophobic materials

Falde, Eric John 17 February 2016 (has links)
The wetting of a rough material is controlled by surface chemistry and morphology, the liquid phase, solutes, and surfactants that affect the surface tension with the gas phase, and environmental conditions such as temperature and pressure. Materials with high (>150˚) apparent contact angles are known as superhydrophobic and are very resistant to wetting. However, in complex biological mixtures eventually protein adsorbs, fouling the surface and facilitating wetting on time scales from seconds to months. The work here uses the partially-wetted (Cassie-Baxter) to fully-wetted (Wenzel) state transition to control drug delivery and to perform surfactant detection via surface tension using hydrophobic and superhydrophobic materials. First there is an overview of the physics of the non-wetting state and the transition to wetting. Then there is a review of how wetting can be controlled by outside stimuli and applications of these materials. Next there is work presented on controlling drug release using superhydrophobic materials with controlled wetting rates, with both in vitro and in vivo results. Then there is work on developing a sensor based on this wetting state transition and its applications toward detecting solute levels in biological fluids for point-of-care diagnosis. Finally, there is work presented on using these sensors for detecting the alcohol content in wine and spirits.
192

Avaliação da dissolução pulpar, tensão superficial e limpeza dos canais radiculares com hipoclorito de cálcio : estudo in vitro / Evaluation of dissolving pulp, surface tension and cleaning of the root canal with calcium hypochlorite : in vitro study

Carlotto, Israel Bangel January 2015 (has links)
O objetivo do presente estudo foi determinar a capacidade de dissolução tecidual, tensão superficial, e capacidade de limpeza de soluções Ca(OCl)2 e compará-las ao NaOCl. A dissolução tecidual foi testada em fragmentos de polpas bovinas divididos em 18 grupos, metade deles utilizando as amostras livremente depositadas em poços de cultura de células e a outra metade utilizando as amostras fixadas em bases de dentina bovina. As soluções testadas foram o NaOCl a 0,5%, 1%, 2,5% e 5,25% e o Ca(OCl)2 a 0,5%, 1%, 2,5% e 5,25%. O grupo controle foi o soro fisiológico. Essas soluções foram empregadas sobre as amostras com dez irrigações/aspirações sucessivas de 1 minuto. A capacidade de dissolução foi mensurada pela percentagem de perda de peso. A tensão superficial do NaOCl a 0,5%, 1%, 2,5% e 5,25% e do Ca(OCl)2 a 0,5%, 1%, 2,5% e 5,25%, além de um grupo controle, água destilada, foi mensurada através da técnica do anel de platina com um tensiômetro de Du Noüy. Foram realizadas nove mensurações de cada solução e o resultado expresso em média e desvio padrão. Para a análise da capacidade de limpeza foram utilizados 50 dentes monorradiculares humanos, divididos em 5 grupos, que foram preparados com limas tipo K e irrigados com NaOCl a 2,5%, NaOCl 5,25%, Ca(OCl)2 2,5% ou Ca(OCl)2 5,25%. O grupo controle foi irrigado com soro fisiológico. Através da microscopia eletrônica de varredura foram analisados os diferentes terços dos canais quanto à remoção de debris e à presença de smear layer. Foram atribuídos escores de 1 a 4 e a frequência destes foi verificada para cada grupo. Os resultados mostraram que quanto à dissolução não houve diferença significante entre NaOCl e Ca(OCl)2 para iguais concentrações. As soluções mais concentradas foram mais eficazes na dissolução. Os valores de tensão superficial das soluções de Ca(OCl)2 variaram de 68,48 a 72,88 mJ/m. A remoção de debris do grupo do Ca(OCl)2 a 5,25% foi inferior ao grupo controle no terço cervical. Nos demais terços não houve diferença entre os grupos. Quanto à remoção de smear layer, não houve diferença entre os grupos. As soluções de hipoclorito de cálcio apresentam capacidade de dissolução tecidual, entretanto suas tensões superficiais foram superiores quando comparadas às soluções de hipoclorito de sódio. Além disso, não foram capazes de remover a smear layer e debris. / The aim of this study was to determine the tissue dissolution capacity, surface tension, and cleaning ability of Ca(OCl)2 solutions and compare to the NaOCl properties. The dissolution was tested on bovine pulps fragments divided into 18 groups, half of them was freely deposited samples in cell culture wells and the remaining samples were fixed on bovine dentin bases. The solutions tested were 0.5% NaOCl, 1.0% NaOCl, 2.5% NaOCl and 5.25% NaOCl, and 0.5% Ca(OCl)2, 1.0% Ca(OCl)2, 2.5% Ca(OCl)2, and 5.25% Ca(OCl)2. The control group was saline. These solutions were used on samples and were successively irrigated/aspirated 10 times, for 1 minute each. The dissolving capacity was measured by the percentual weight loss. The surface tension of all tested solutions and control was measured by the platinum ring technique with a Du Noüy tensiometer. Nine measurements were taken of each solution and the result expressed as mean and standard deviation. For the analysis of cleaning capacity, 50 monoradicular human teeth were divided into five groups. They were prepared with K files and irrigated with 2.5% NaOCl, 5.25% NaOCl, 2.5% Ca(OCl)2 or 5.25% Ca(OCl)2. The control group was irrigated with saline. The samples were analyzed by scanning electron microscopy. Each third of the root canals received a score regarding the removal of debris and the presence of smear layer. Scores were assigned from 1 to 4 and their frequency for each group was determined. There was no significant difference between NaOCl and Ca(OCl)2 with the same concentrations. The most concentrated solutions were more effectively in dissolution. The surface tension values of solutions for Ca(OCl)2 varied from 68.48 to 72.88 mJ/m. Debris removal for 5.25% Ca(OCl)2 was lower than the control group in the cervical third. In the other thirds there was no difference among groups. There was no difference for the smear layer removal among groups. Calcium hypochlorite solutions showed tissue dissolution ability, however their surface tensions were higher when compared with sodium hypochlorite solutions. Moreover, were not able to remove debris and smear layer.
193

Gliding Arc / Gliding Arc

KALA, Jaroslav January 2012 (has links)
The thesis is focused on increasing the surface tension of polyethylen, using plasma. A gliding arc was chosen for this surface modi cation. The theoretical part includes an overview of gas discharges, their classi cation, properties and technical applications, and deals with an in uence of surface tension on surface modi cations of materials. The experiment is explained in the practical part, a jet analysis carried out before the experiment is described. Results of the experiment are presented.
194

Modelagem da tensão superficial de misturas de hidrocarbonetos / Modeling surface tension of hydrocarbons mixtures

Elizabeth Salviano Bezerra 27 August 2007 (has links)
Esta dissertação apresenta um novo modelo criado para a previsão do valor da tensão superficial de misturas de hidrocarbonetos. Pode ser utilizado na forma preditiva ou correlativa. Este modelo foi baseado no modelo preditivo para soluções ideais de HildebrandScott (1950) e no modelo correlativo de JouybanAcree (2004). Outras regras de mistura foram avaliadas e comparadas com o modelo proposto, incluindo abordagens clássicas como de Sprow e Prausnitz, parácoro e estados correspondentes. Foram avaliados os desempenhos dos modelos escolhidos na previsão e na correlação da tensão superficial de misturas de hidrocarbonetos em diferentes temperaturas que continham diferentes assimetrias na mistura, tanto em natureza química (e.g., parafínicos, naftênicos e aromáticos) quanto em tamanho de cadeia. No total foram empregados 773 dados experimentais. Dentre os modelos preditivos, o modelo proposto foi o de melhor desempenho. Para sistemas com comportamento próximo da idealidade, esse modelo apresentou desvios em relação aos dados experimentais compatíveis com o erro experimental. Todos os modelos correlativos estudados apresentaram desvios essencialmente da ordem do erro experimental. O modelo proposto é importante, pois é capaz de prever a tensão superficial de misturas binárias aproximadamente ideais de hidrocarbonetos com elevada acurácia, além de permitir a correlação eficiente dos dados de todas as misturas estudadas / This dissertation presents a new model created for the prediction of the value of the surface tension of hydrocarbons mixtures. It can be used in a predictive or correlative way. This model was based on the predictive model for ideal solutions of Hildebrand-Scott (1950) and on the correlative model of Jouyban-Acree (2004). Other mixing rules had been evaluated and compared with the proposed model, including classic approaches like Sprow and Prausnitz, parachor, and corresponding states. There was evaluated the performance of the chosen models in the prediction and the correlation of the surface tension of hydrocarbons mixtures at different temperatures that contained different asymmetries in the mixture, as in chemical nature (e.g., parafinics, naftenics and aromatics) as well as in chain size. The total of 773 experimental data had been used. The proposed model had the best performance among the predictive models. This model showed errors essentially of the order of the experimental error for approximately ideal systems. All of the correlative models studied have shown errors essentially of the order of the experimental error. The proposed model is important because it is capable of predicting the surface tension of approximately ideal binary mixtures of hydrocarbons with high accuracy, beyond permitting the efficient correlation of the data of all the studied mixtures
195

Efetividade in situ do Chlor-Xtra na dissolução do tecido pulpar em canais radiculares ovais / Sodium hypoucorite with reduced surface tension does not improve insire pulp dissolution

Marco André de Berredo Pinho 19 February 2013 (has links)
O objetivo deste estudo foi avaliar a dissolução do tecido pulpar pelo NaOCl contendo em sua composição agentes redutores da tensão superfical (Chlor-Xtra) quando comparados ao NaOCl convencional. Com esta finalidade 44 dentes unirradiculares humanos com tecido pulpar preservado em solução de formol a 10% foram agrupados em 22 pares de acordo com a semelhança de sua anatomia interna previamente avaliada por radiografias. Os canais foram instrumentados com sistema Protaper Universal e todo o processo de irrigação teve, além do tempo, seu volume e fluxo controlado por meio automatizado por meio do sistema Vatea Endodontic Iirrigation Device. Após cada canal que compunha um par ter sido instrumentado empregando-se uma das diferentes soluções testadas, as quais foram previamente avaliadas quanto a sua tensão superficial, ambos foram devidamente preparados e enviados para processamento e análise histológica. Cortes a 0,5, 1,2,3 e 4mm do ápice foram realizados, corados e fotografados. As imagens foram analisadas por meio do programa AxioVision a fim de estabelecer o percentual de tecido remanescente em relação à área total do canal nos segmentos estudados. As análises referentes a tensão superficial revelaram que o Chlor-Xtra demonstrou possuir significativamente menor tensão superficial quando comparado ao NaOCL convencional (p>0,05). A análise estatística por meio do test T student das áreas dos canais, demonstrou que o pareamento das amostras foi eficiente entre os grupo NaOCl e Chlor-Xtra (p>0,05). Em relação ao Percentual de Tecido Remanescente (PTR), os resultados revelaram por meio de análise feita pelo teste Kruskal-Wallis e o teste de correlação de Spearman que o nível de corte influencia significantemente o PTR (P<0,05).Por fim, o teste de Mann-Whitney indicou que o PTR não é influenciado pela solução irrigadora utilizada (P>0,05). A partir da análise dos resultados foi possível concluir que quanto mais apicalmente foi o nível de corte histológico dos canais estudados, maior foi o percentual de tecido pulpar remanescente independentemente da solução utilizada, portanto.não houve diferença significativa na qualidade do debridamento produzido pelas duas soluções testadas, desta forma indicando que a presença de agentes modificadores da tensão adicionados ao NaOCl não foi capaz de superar os resultados obtidos por soluções de NaOCl convencionais. / Sodium hypochlorite solutions with added wetting agents are advertised to dissolve necrotic tissue in root canals faster than counterparts without lowered surface tension. This was tested in the current study using extracted, single-rooted teeth with oval canals that contained pulp tissue. Formerly vital extracted teeth (N = 44) with similar anatomy were radiographically paired and chemomechanically prepared. In one tooth, a 5.25% NaOCl solution with reduced surface tension was used, in the other a pure, technical-grade NaOCl solution of 5.25%. Percentage of remaining pulp tissue (PRPT) was histologically assessed in root cross-sections. The non-Gaussian raw data was subjected to Kruskal-Walis and Mann-Whitney U tests to verify the respective effect of level of cross-section and solution on the PRPT.The relationship between level of cross-section and PRPT was estimated by Spearman correlation test. Alpha-type error was set at 5%. The level of section significantly influenced the PRPT (P<0.05), whereas the PRPT was not influenced by the solution used (P>0.05). A significant inverse correlation was found between the level of section and PRPT (P<0.05, r = -0.330). The lower the distance to the apex, the higher the PRPT, regardless of the solution used.Contrary to the advertised statement, the dental solution with reduced surface tension did not dissolve vital pulp tissue in oval root canals any better than a conventional NaOCl solution of similar strength. Closer to the apex, pulp tissue dissolution is less efficient, irrespective of the solution.
196

Synthesis and Characterization of Novel Silicone Graft Copolymers

January 2016 (has links)
abstract: Silicone compounds have a very low surface energy due to highly flexible Si-O-Si backbone and large number of –CH3 groups, but these compounds are extremely hydrophobic and thus have limited applications in aqueous formulations. Modification of such silicone compounds by grafting hydrophilic chains provides a wide range of silicone products called "Silicone Surfactants". Silicone surfactants are surface active agents which get adsorbed at the air-water interface thereby, reducing the interfacial tension. Some of the larger applications of silicone surfactant are in the manufacture of plastic foams, in personal care products and as spreading and wetting agents (Hill, R.M, 2002). In this thesis, a series of silicone surfactant graft copolymers were synthesized via hydrosilylation reaction. Poly(ethylene glycol) (PEG) of different chain length was grafted to a hydrophobic Poly(methylhydrosiloxane) (PMHS) backbone to improve the final hydrophilicity. Also, a positively charged quaternary ammonium salt (allyltriethylammonium bromide) was grafted to the PMHS backbone. The objective of this thesis was to synthesize polymers in predefined ratios of the above mentioned side groups and utilize these polymers to- 1) Study the effect of PEG chain length and its composition on the hydrophilicity of the polymer. 2) Study the effect of PEG: ammonium salt ratio on the surface tension of aqueous systems. Analysis of FT-IR and 1H NMR spectra of the polymers confirmed the predicted structure. The absence of characteristic Si-H absorbance peak at 2160 cm-1 in FT-IR spectra indicates consumption of silane groups along the polymer backbone. The actual moles of the side chain grafted on the backbone are calculated by 1H NMR peak integration. The results of contact angle studies indicated an increase in hydrophilicity with an increase in the composition of PEG in molecule. A 2*2 factorial DOE analysis reported that the fraction of Si-H bonds converted to PEG grafts was the critical factor towards increasing the hydrophilicity (p value of 0.015). Surface tension studies report that the air-water interfacial tension of the synthesized polymers is between 28mN/m – 45mN/m. The amount of Si-H was concluded to be the deciding factor in lowering the surface tension. / Dissertation/Thesis / Masters Thesis Chemical Engineering 2016
197

Efeitos dos parâmetros de soldagem GMAW com curva controlada na união dos aços dissimilares ASTM A572 grau 50 e ASTM A36

Wanderlind, Augusto January 2018 (has links)
Dissertação de mestrado apresentada ao Programa de Pós-Graduação em Ciência e Engenharia de Materiais – PPGCEM da Universidade do Extremo Sul Catarinense – UNESC, como requisito à obtenção do título de Mestre em Ciência e Engenharia de Materiais. / A ligação soldada é de suma importância em estruturas de aço, necessitam de projetos estruturais e ajustes de processamento, para obter resistência mecânica e durabilidade. O processo de soldagem vem utilizando recursos eletrônicos para o controle das curvas de corrente e tensão, fato que faz surgir novos parâmetros de controle. Estes parâmetros possuem ranges limitados pela espessura das chapas a serem unidas, tipologia do aço utilizado e transferência metálica adotada. Assim, foram escolhidos para este estudo os aços ASTM A572 Gr50 e ASTM A36 com espessuras diferentes, pois possuem utilização expressiva em obras civis e industriais. O intuito deste estudo é otimizar a utilização do processo de soldagem GMAW (Gas Metal Arc Welding) MAG (Metal Active Gas) com curva controlada e transferência metálica por STT (Surface Tension Transfer). Para isto, foi proposto um planejamento experimental fatorial 2³ completo, com ponto central em réplica, avaliando a velocidade de alimentação (Va), o foco da coluna do arco elétrico (FC) e a amplitude entre a corrente de pico e a corrente de base (APB). Foram realizados testes experimentais, a fim de mensurar a energia de soldagem, a eficiência de deposição, a geometria do cordão de solda, a resistência mecânica, bem como analisar a microestrutura formada na região da solda, o potencial de corrosão e o perfil de dureza Vickers passando pelos metais de base (MB), zona termicamente afetada (ZTA), zona fundida (ZF) e metal de solda (MS). Todos os testes foram realizados em corpos de prova cruciformes, para evitar a interferência na interpretação dos resultados, por diferenças na transferência de calor. Os resultados obtidos apontam um valor ótimo de energia de soldagem, que promove baixa alteração microestrutural, com poucas alterações no perfil de microdureza e uma geometria de filete de solda sem defeitos e com previsão, através de modelo matemático, da área resistente.
198

Aplicação localizada e em área total de inseticida e óleo mineral com pontas de pulverização e volume de aplicação, na cultura da soja / Localized application and in total area of insecticide and mineral oil with nozzle and spray volume, in soybeans crop

Simino, Paulo Eduardo Rezende [UNESP] 02 August 2016 (has links)
Submitted by PAULO EDUARDO REZENDE SIMINO null (paulosimino@gmail.com) on 2016-09-01T18:09:16Z No. of bitstreams: 1 Dissertação_Paulo Simino_Jaboticabal.pdf: 1462778 bytes, checksum: c8cd31153cc4ec61ff18eddff25a9bf0 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-09-02T20:14:10Z (GMT) No. of bitstreams: 1 simino_per_me_jabo.pdf: 1462778 bytes, checksum: c8cd31153cc4ec61ff18eddff25a9bf0 (MD5) / Made available in DSpace on 2016-09-02T20:14:10Z (GMT). No. of bitstreams: 1 simino_per_me_jabo.pdf: 1462778 bytes, checksum: c8cd31153cc4ec61ff18eddff25a9bf0 (MD5) Previous issue date: 2016-08-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os principais métodos de aplicação de produtos fitossanitários na soja são aérea e terrestre, sendo essa feita com barra em área total. Ambas apresentam desuniformidades de cobertura e depósito no perfil vertical da planta, geralmente baixa no terço inferior, o que pode comprometer a eficiência do tratamento, dentre eles o controle de pragas. O presente trabalho avaliou a qualidade da aplicação localizada do inseticida clorpirifós (CapatazBR) realizada com pingentes posicionados na entre linha da cultura. O delineamento dos ensaios de campo foi no esquema fatorial 2 x 3, sendo dois modelos de pontas na aplicação com pingente (XR 11001 e TXA 8001) e três concentrações do óleo mineral Nimbus® (0; 0,5 e 3,0% v/v), além de um tratamento adicional que avaliou a aplicação em área total com pontas do modelo TT 110015. Foi avaliado duas taxas de aplicação (80 e 150 L ha-1) em duas localidades, perfazendo quatro experimentos, quando determinou-se a porcentagem de cobertura e o depósito nos diferentes terços da planta e o depósito total por planta. Avaliou-se em laboratório importantes parâmetros da calda, como a tensão superficial, ângulo de contato da gota com a folha de soja e uma superfície padrão de Parafilm®, a taxa de evaporação e o pH. Esses ensaios foram conduzidos no esquema fatorial 3x2, sendo três concentrações do óleo mineral (0; 0,5 e 3,0% v/v) e duas concentrações equivalentes às taxas de aplicação 80 e 150 L ha-1. De acordo com os resultados, a cobertura e o depósito foram menores para o terço inferior, tanto na aplicação localizada como em área total. A ponta XR apresentou-se com maior capacidade de depósito nos diferentes terços da planta em comparação à ponta TXA, mas o depósito total referente à somatória dos depósitos nos três terços apresentou-se igual entre ambas as pontas e as modalidades de aplicação área total e localizada. A simples adição de inseticida foi suficiente para reduzir a tensão superficial e o ângulo de contato da gota para as superfícies soja e Parafilm® em relação à água. A associação de 0,5% de óleo mineral ao inseticida reduziu o ângulo de contato da gota depositada sobre a superfície do Parafilm® em ambas as taxas de aplicação, enquanto que na soja nenhuma concentração de óleo mineral alterou o ângulo da gota. A calda referente ao volume de 80 L ha-1 e sem adjuvante apresentou a menor tensão superficial, porém proporcionou o pior espalhamento da gota na folha de soja. Nenhuma dose do adjuvante proporcionou efeito na evaporação da gota pendente. O inseticida reduziu o pH da calda e o adjuvante não interferiu nesse parâmetro. / The main methods for pesticide application in soybean are by aircraft and tractor using sprayer boom in total Área. Both of them present non-uniformity of coverage and deposit on the vertical profile of the plant, usually low in the bottom third, which can compromise the efficiency of the treatment, including pest control. This study evaluated the quality of the localized application of the insecticide chlorpyrifos (CapatazBR) performed with hose drops positioned in line between the culture. The design of field trials was in a factorial 2 x 3, two models of nozzle on application in hose drop (XR 11001 and TXA 8001) and three mineral oil concentrations Nimbus® (0, 0.5 and 3.0% v / v), plus an additional treatment evaluating the total Área of application with a model of nozzle TT 110015. It was evaluated two spray volumes (80 and 150 L ha-1) in two locality, that is four experiments. It was determined the percentage of coverage and deposition in different thirds of the plant and the total deposit per plant. It was evaluated in a laboratory important parameters such as surface tension, contact angle of the droplet with soybean leaf pattern and a Parafilm® surface, the evaporation rate and pH. These trials were conducted in a 3x2 factorial arrangement, with three concentrations of mineral oil (0, 0.5 and 3.0% v / v) and two concentrations equivalent to application rates of 80 and 150 L ha-1. According to the results, coverage and the deposit was lower for the lower third in both the localized application and in total Área. The nozzle XR presented with greater deposit capacity in the different thirds of the plant compared to the nozzle TXA, but the total deposit (sum of the three thirds) were equal between both nozzle models and the application types. The simple addition of insecticide was sufficient to reduce the surface tension and contact angle of the droplet to the surfaces soybean and Parafilm compared to water. The combination of 0.5% mineral oil to the insecticide reduced the contact angle of the droplet deposited on the surface of Parafilm at both application rates, whereas in soybean no mineral oil concentration alter the angle of the drop. The treatement related to application rate of 80 L ha-1 and without mineral oil had the lowest surface tension, but provided the worst spreading drop in soybean leaves. No adjuvant concentration provided effect in the evaporation pendant drop. The insecticide reduced the pH and the adjuvant did not affect this parameter.
199

Aplicação localizada e em área total de inseticida e óleo mineral com pontas de pulverização e volume de aplicação, na cultura da soja /

Simino, Paulo Eduardo Rezende. January 2016 (has links)
Orientador: Marcelo da Costa Ferreira / Banca: Arlindo Leal Boiça Junior / banca: João Paulo Arantes Rodrigues da Cunha / Resumo: Os principais métodos de aplicação de produtos fitossanitários na soja são aérea e terrestre, sendo essa feita com barra em área total. Ambas apresentam desuniformidades de cobertura e depósito no perfil vertical da planta, geralmente baixa no terço inferior, o que pode comprometer a eficiência do tratamento, dentre eles o controle de pragas. O presente trabalho avaliou a qualidade da aplicação localizada do inseticida clorpirifós (CapatazBR) realizada com pingentes posicionados na entre linha da cultura. O delineamento dos ensaios de campo foi no esquema fatorial 2 x 3, sendo dois modelos de pontas na aplicação com pingente (XR 11001 e TXA 8001) e três concentrações do óleo mineral Nimbus® (0; 0,5 e 3,0% v/v), além de um tratamento adicional que avaliou a aplicação em área total com pontas do modelo TT 110015. Foi avaliado duas taxas de aplicação (80 e 150 L ha-1) em duas localidades, perfazendo quatro experimentos, quando determinou-se a porcentagem de cobertura e o depósito nos diferentes terços da planta e o depósito total por planta. Avaliou-se em laboratório importantes parâmetros da calda, como a tensão superficial, ângulo de contato da gota com a folha de soja e uma superfície padrão de Parafilm®, a taxa de evaporação e o pH. Esses ensaios foram conduzidos no esquema fatorial 3x2, sendo três concentrações do óleo mineral (0; 0,5 e 3,0% v/v) e duas concentrações equivalentes às taxas de aplicação 80 e 150 L ha-1. De acordo com os resultados, a cobertura e o depósito fo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The main methods for pesticide application in soybean are by aircraft and tractor using sprayer boom in total Área. Both of them present non-uniformity of coverage and deposit on the vertical profile of the plant, usually low in the bottom third, which can compromise the efficiency of the treatment, including pest control. This study evaluated the quality of the localized application of the insecticide chlorpyrifos (CapatazBR) performed with hose drops positioned in line between the culture. The design of field trials was in a factorial 2 x 3, two models of nozzle on application in hose drop (XR 11001 and TXA 8001) and three mineral oil concentrations Nimbus® (0, 0.5 and 3.0% v / v), plus an additional treatment evaluating the total Área of application with a model of nozzle TT 110015. It was evaluated two spray volumes (80 and 150 L ha-1) in two locality, that is four experiments. It was determined the percentage of coverage and deposition in different thirds of the plant and the total deposit per plant. It was evaluated in a laboratory important parameters such as surface tension, contact angle of the droplet with soybean leaf pattern and a Parafilm® surface, the evaporation rate and pH. These trials were conducted in a 3x2 factorial arrangement, with three concentrations of mineral oil (0, 0.5 and 3.0% v / v) and two concentrations equivalent to application rates of 80 and 150 L ha-1. According to the results, coverage and the deposit was lower for the lower third in both... (Complete abstract click electronic access below) / Mestre
200

Dentina humana e bovina: estudo comparativo das propriedades físicas e características da hibridização de sistemas adesivos convencionais ou grander modificados: análise em mev /

Gonçalves, Sérgio Eduardo de Paiva. January 2005 (has links)
Resumo: A adesão longitudinal continua a representar um dos maiores desafios da Odontologia moderna. Uma nova proposta para o estabelecimento do equilíbrio da adesão aos tecidos dentários surge, baseada na observação dos resultados obtidos com a tecnologia Grander para revitalização da água. Objetiva-se com o estudo verificar a influência dessa tecnologia nas propriedades físicas de dois sistemas adesivos (convencional e autocondicionante) à partir da medição da tensão superficial e do ângulo de contato; e avaliar a formação e a qualidade da camada híbrida em dentina humana e bovina. A tensão superficial de quatro diferentes líquidos (água, Single Bond- 3M, Primer do Clearfil SE Bond -Kuraray, e Bond do Clearfil SE-Kuraray), foi medida antes e após a modificação pelo procedimento Grander em aparelho goniômetro (Ramé-hart). O ângulo de contato com três substratos distintos (placa de titânio, dentina humana e dentina bovina), foi medido para os quatro líquidos também antes e após a modificação pelo procedimento Grander, também em goniômetro. A formação e qualidade da camada híbrida, foi avaliada em MEV, a partir da confecção de corpos de prova dos substratos humano e bovino, devidamente embutidos, preparados em lixas de variada granulação até a exposição de dentina, submetidos ao procedimento adesivo (SB ou CSEB) normal ou grander modificado, recebendo ao final dupla camada de resina composta Z250-3M, fotopolimerizada por 40s. Após armazenamento em estufa bacteriológica por 24h, os procedimentos para análise ao MEV foram realizados (fixação, desidratação, secagem e metalização). A estatística de Análise de Variância ANOVA e Teste de Tukey 5% revelou que: houve redução estatisticamente significante da tensão superficial para todos os líquidos Grander modificados; houve redução estatisticamente... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: A long-lasting adhesion is still one of the biggest challenges of the modern Dentistry. A new approach to reaching the equilibrium of the adhesion to the dental tissues emerges based on the observation of the results obtained with the Grander Technology for revitalizing water. The aim of this study was to verify the influence of this technology on the physical properties of two adhesive systems (conventional and self-etching) through the measurement of the surface tension and of the contact angle and through the evaluation of the formed hybrid layer in human and bovine dentin. The surface tension of four different liquids (water, Single Bond - 3M, Clearfil SE primer - Kuraray and Clearfil SE bond - Kuraray) was measured before and after submitting these liquids to the Grander modifying unit, with the aid of a goniometer (Ramé-hart). The measurement of the contact angle of the liquids followed the same procedure using three distinct surfaces: titanium plate, human dentin and bovine dentin. The hybrid layer formed for both: non-modified and Grander modified adhesive systems, was evaluated in SEM. For this purpose human and bovine dentin samples were prepared. The teeth were fixed in acrylic resin and the dentin surfaces exposed and finished with various grit polishing paper discs. These dentin surfaces were then treated with the adhesive procedures (normal and Grander modified), before the placement of a double composite resin layer (Z250- 3M). After storage at 37oC for 24h, the SEM analysis were conducted. The data were submitted to ANOVA and Turkeys test 5%. The results showed statistically significant reduction for the surface tension of all liquids modified by the Grander technology, as well as for the contact angle in the human dentin. Statistically significant were also the results showing a thicker hybrid layer formation with the two adhesive systems when modified by the Grander... (Complete abstract click electronic access below)

Page generated in 0.0916 seconds