Sustained Load Behaviour of Reinforced Concrete FramesDanielsen, Ronald, C.T. 03 1900 (has links)
Methods are presented for the predication of the short-term and sustained load behaviour of reinforced concrete frames. These procedures are evaluated by an experimental program using a particular structure and loading configuration. The results of two short-term tests and one sustained load test are compared with the analytic predictions. The inadequacy of classical methods of structural analysis for sustained load problems is also discussed. It is concluded that the methods using small elements, numerical integration and successive iterations can provide accurate predictions of short-term and sustained load behaviour of reinforced concrete beams. / Thesis / Master of Engineering (ME)
|
2 |
Combined effects of freeze-thaw and sustained loads on reinforced concrete beams strengthened with FRPsOldershaw, Brant 03 March 2008 (has links)
Fibre reinforced polymer (FRP) materials have emerged as an innovative tool within the civil engineering community for the strengthening and rehabilitation of existing reinforced concrete structures. Research has taken place over the past decade that has demonstrated the benefits of FRPs, and it is evident that there is a need for their usage given the status of the deteriorated North American civil infrastructure. However, in order to increase confidence in the application of these materials in Canada, further information is required to fully understand their behaviour in cold climates.
This thesis expands on the previous research that has taken place at Queen’s University, investigating the freeze-thaw behaviour of FRP strengthened reinforced concrete. The research program herein studies the combined effects of freeze-thaw cycling and sustained loading on the flexural performance of 45 small-scale beams strengthened with glass FRP sheets, carbon FRP sheets, or carbon FRP plates. In an attempt to attain failure of the beams due to FRP rupture, the anchorage of the beams was increased and a theoretical model was produced to select the beam design for this failure mode. The model also predicted the performance of the strengthened beams in order to determine appropriate sustained loading levels. After being subjected to 300 freeze-thaw cycles and almost 3 months of sustained loads, the beams were tested to failure. It was found that the beams subjected to combined loads encountered virtually no losses in average ultimate strength. However, the greater inconsistency of the results for these beams relative to the control beams implies that lower guaranteed strengths should be used for design in situations where these conditions are present. / Thesis (Master, Civil Engineering) -- Queen's University, 2008-02-29 14:19:29.954
|
3 |
Bonded Anchors in Concrete Under Sustained LoadingDroesch, Douglas 17 July 2015 (has links)
Post installed anchors come in either mechanical anchors that develop their strength purely through mechanical interlock with the base concrete, or bonded anchors that develop their strength by bonding anchor rod to the base concrete. Bonded anchors are either grouted, typically cementitious material, or adhesive, typically a chemical material. This thesis presents a current literature review of post-installed bonded anchors, preliminary testing of adhesive bonded anchors, and details of short term and long term test setups for future testing. The purpose of this thesis was to develop the test setups that will be used for future testing on anchors.
|
4 |
On Short-term and Sustained-load Analysis of Concrete FramesTan, King-Bing January 1972 (has links)
<p> A Matrix Stiffness-Modification Technique has been proposed
for the inelastic analysis of ·reinforced concrete frames subjected
to short term or sustained loads. To check the applicability of the
analytical method, two large scale concrete frames were tested
under short-term loads and sustained-loads respectively. In
addition, data for twenty-two frame tests from other sources
has also been compared with the non-linear analysis. Close
agreement has. been observed for all the frames considered.
It was further concluded that a conventional elastic matrix
method using stiffnesses based on a cracked transformed section
of concrete does net yield accurate results, especially in the
case of sustained loading conditions. From the method developed,
comments can therefore be made on present column design practice. </p> / Thesis / Master of Engineering (MEngr)
|
5 |
Creep Behaviour of Post-Installed Adhesive Anchors under Various Sustained Load Levels and Environmental ExposuresEl Menoufy, Adham Mohamed 08 1900 (has links)
This thesis describes an experimental study on the long-term creep behaviour of adhesive anchors under sustained tensile loads in combination with different environmental exposures. A comprehensive background and literature review is presented, focusing on various bond stress models for adhesive anchors, factors affecting their bond behavior, and an overview of available testing standards and evaluation criteria. The experimental program comprises of 82 test specimens. The specimens consist of a cylindrical shaped concrete block of 300 mm (12 inch) in diameter and 200mm (8 inch) in depth, with 15M (No. 5) deformed steel bar post-installed to an embedment depth of six times the bar diameter or 125mm (5 inch). Three types of adhesives were used for anchor installation: Type-A a fast setting two component methyl methacrylate adhesive, Type-B a fast setting two part epoxy adhesive, and Type-C a standard set two part epoxy adhesive.
The study is divided into four phases. Phase I consists of 27 static pullout tests to determine the yield strength (fy) and the maximum tensile capacity of each anchor system under three exposure conditions. Phase II and Phase III consist of 36 specimens tested under sustained load levels of 40%fy (32kN) and 60%fy (48kN)under normal laboratory conditions (room temperature) and moisture exposure, respectively. Phase IV consists of 9 specimens tested under sustained load with a load level of 40%fy (32kN) with exposure to freeze/thaw cycling. All sustained load tests lasted for a period of at least 90 days.
The results of the static pullout testing showed that specimens with epoxy based adhesive exhibited stronger bond strength, forcing the anchor to fail by rupture prior to bond failure. Under sustained load testing, specimens with standard set epoxy based adhesive showed insignificant creep displacement under room conditions, however, when exposed to moisture noticeable creep displacements were recorded. Specimens with both fast setting epoxy and methyl methacrylate based adhesives showed higher creep displacements under environmental exposure (moisture, freeze/thaw) versus those kept at room temperature.
Displacement data from creep testing were analysed and projected over a service life span of 50 years for room temperature exposure, and for 10 years for moisture and freeze/thaw exposures. Based on the analysis results, the service life of different anchor systems was estimated. An integrated qualification and testing protocol is proposed for the creep behavior of adhesive anchors under various environmental exposures.
|
6 |
Creep Behaviour of Post-Installed Adhesive Anchors under Various Sustained Load Levels and Environmental ExposuresEl Menoufy, Adham Mohamed 08 1900 (has links)
This thesis describes an experimental study on the long-term creep behaviour of adhesive anchors under sustained tensile loads in combination with different environmental exposures. A comprehensive background and literature review is presented, focusing on various bond stress models for adhesive anchors, factors affecting their bond behavior, and an overview of available testing standards and evaluation criteria. The experimental program comprises of 82 test specimens. The specimens consist of a cylindrical shaped concrete block of 300 mm (12 inch) in diameter and 200mm (8 inch) in depth, with 15M (No. 5) deformed steel bar post-installed to an embedment depth of six times the bar diameter or 125mm (5 inch). Three types of adhesives were used for anchor installation: Type-A a fast setting two component methyl methacrylate adhesive, Type-B a fast setting two part epoxy adhesive, and Type-C a standard set two part epoxy adhesive.
The study is divided into four phases. Phase I consists of 27 static pullout tests to determine the yield strength (fy) and the maximum tensile capacity of each anchor system under three exposure conditions. Phase II and Phase III consist of 36 specimens tested under sustained load levels of 40%fy (32kN) and 60%fy (48kN)under normal laboratory conditions (room temperature) and moisture exposure, respectively. Phase IV consists of 9 specimens tested under sustained load with a load level of 40%fy (32kN) with exposure to freeze/thaw cycling. All sustained load tests lasted for a period of at least 90 days.
The results of the static pullout testing showed that specimens with epoxy based adhesive exhibited stronger bond strength, forcing the anchor to fail by rupture prior to bond failure. Under sustained load testing, specimens with standard set epoxy based adhesive showed insignificant creep displacement under room conditions, however, when exposed to moisture noticeable creep displacements were recorded. Specimens with both fast setting epoxy and methyl methacrylate based adhesives showed higher creep displacements under environmental exposure (moisture, freeze/thaw) versus those kept at room temperature.
Displacement data from creep testing were analysed and projected over a service life span of 50 years for room temperature exposure, and for 10 years for moisture and freeze/thaw exposures. Based on the analysis results, the service life of different anchor systems was estimated. An integrated qualification and testing protocol is proposed for the creep behavior of adhesive anchors under various environmental exposures.
|
7 |
Performance of confined concrete columns under simulated life cyclesHart, Steven D. January 1900 (has links)
Doctor of Philosophy / Department of Civil Engineering / Asadollah Esmaeily / Over the past 30 years, FRP composites (carbon, glass, or aramid fibers) have arisen as a method of retrofitting existing reinforced concrete structures to bring them up to current code standards of confinement and ductility. The development of stress-strain models for FRP confined concrete began with the adaptation of steel confinement models then progressed to models specifically developed based on test results from FRP confined specimens. State of the art stress-strain models for FRP confined concrete models may now be validated against a wide variety of published experimental results. Recent publications show researchers branching out and looking at other aspects of FRP confined concrete behavior, including the impact of sustained service loads on long term and ultimate behavior. An experimental program which examines the effects of sustained service loading on the ultimate axial performance of FRP confined concrete is presented. The program's purpose is to determine whether or not a material model developed without the presence of a sustained load accurately predicts the ultimate stress-strain response of FRP confined concrete previously subjected to a sustained service load. Equipment and procedures were developed to model the critical events in a building life cycle: construction, sustained service loading, minor critical events, rehabilitation, and ultimate performance. Varying the order of these events produces a simulated life cycle allowing analysis of the impact of strain history on ultimate performance. The results of the experimental program indicate that the presence of a sustained service load changes the expected failure mode from FRP rupture to FRP de-lamination and the stress-strain response of a specimen is approximately 10% below published models when sustained service loads are included in the life cycle. A comprehensive modeling process is proposed for modeling significant events in a structure's life cycle. Impacts on earthquake engineering and reliability studies are addressed and future research suggested. This research shows that life cycle modeling can improve the design and rehabilitation of structures so that they meet safety requirements in future seismic events.
|
8 |
Behaviour of CFRP-Prestressed Concrete Beams under Sustained Loading and High-Cycle Fatigue at Low TemperatureSaiedi, Mohammad Reza 22 December 2009 (has links)
Fibre-reinforced polymers (FRPs) are becoming increasingly accepted in structural engineering applications. In particular, Carbon-FRP (CFRP) tendons are proving to be promising as prestressing reinforcement for concrete structures. While several studies have been conducted on CFRP-prestressed concrete beams, very little attention has been given to their long-term behaviour at low temperatures. This thesis investigates the behaviour of CFRP prestressed concrete beams in two studies: (a) under sustained loading at low temperature, and (b) under high-cycle fatigue at low temperature. Seven 13 year old, 4.4 m long precast concrete T beams were tested, of which five were prestressed to various levels with CFRP tendons and two with conventional steel strands.
In the first study, three beams were exposed to −27 °C while being subjected to a sustained load of 25% of their flexural capacity for 163 days. The sustained load produced cracking in two beams with lower prestress levels. Results were compared to those obtained from three similar beams subjected to the same sustained load at room temperature. Deflection increase under sustained load at low temperature was generally small and similar to that at room temperature. Prestressing strain had a direct relationship with temperature in the CFRP prestressed beams.
After being subjected to sustained loading, all seven beams were tested in the second study. Only three of the five CFRP prestressed beams were subjected to cyclic loading, one at −28 °C and two at room temperature, while only one of the two steel prestressed beams was subjected to cyclic loading, at −28 °C. Cyclic loading consisted of 3 million cycles at a frequency of 0.85 Hz. The load range represented 21 to 42% of the flexural capacity of the CFRP prestressed beams and 30 to 60% of that of the steel-prestressed beam. Monotonic tests were run every 1 million cycles. Finally, all seven beams were monotonically loaded to failure. All CFRP prestressed beams survived the 3 million cycles but the steel prestressed beam failed after 185,000 cycles. However, the CFRP concrete bond was weakened by high prestress levels, cyclic loading, and low temperature during sustained loading and loading to failure. This resulted in bond failure at loads ranging from 69 to 91% of the full flexural capacity. Stiffness and camber gradually decreased during cyclic loading. / Thesis (Master, Civil Engineering) -- Queen's University, 2009-12-21 15:16:33.381
|
9 |
Long-Term Deflection Of One-Way Concrete Slab Strips Containing Steel And GFRP ReinforcementDarabi, Mohammadali 14 September 2011 (has links)
Fibre reinforced polymers (FRP’s) are considered an alternative to steel reinforcement in concrete structures because of their noncorrosive nature and nonmagnetic properties. FRP materials are, however, brittle and have a lower stiffness compared to steel. The latter property can lead to deflection and crack control problems in FRP-reinforced concrete flexural members under service loads. A considerable amount of information is available for short-term deflection of FRP-reinforced concrete members, but data on long-term deflections are scarce.
This study presents the results of monotonic (short-term) and sustained (long-term)
loading tests of 12 concrete shallow beams reinforced with either steel or glass FRP
(GFRP) bars. The short-term load-deflection responses of the members are evaluated
using existing deflection prediction models (Branson’s and Bischoff’s), and the long-term deflection results (monitored over a period of one year) are used to evaluate the existing ACI code and CSA standard approaches for estimating long-term deflection. The GFRP-reinforced concrete beams exhibited greater amounts of both immediate deflection (under sustained load) and long-term deflections over time, than the steel-reinforced concrete beams. The long-term deflections of both the steel- and GFRP-reinforced concrete beams are overestimated when using the ACI and CSA approaches. Although ACI Committee 440 recommends use of lower values of the long-term deflection multiplier for GFRP-reinforced concrete beams, results obtained from this study suggest that the same longterm multiplier values may be used for GFRP- and steel-reinforced concrete beams loaded at between 115 to 157 days of concrete age.
|
10 |
Analyse multi-échelles de la viscoplasticité à froid et de la rupture différée du titane en relation avec ses teneurs en hydrogène et oxygène. / Multiscale investigation of room-temperature viscoplasticity and sustained load cracking of Titanium. Influence of hydrogen and oxygen content.Marchenko, Arina 23 November 2015 (has links)
Le titane et ses alliages qui sont largement répandus dans l'industrie aéronautique, sont concernés par le fluage à température ambiante ce qui conduit à une réduction de la résistance et provoque le phénomène de rupture différée. Une partie des études montrent que ce comportement viscoplastique inhabituel à température ambiante est lié aux phénomènes d'interactions entre les dislocations et les atomes interstitiels comme l'hydrogène et l'oxygène, aussi appelés vieillissement statique et dynamique. Le but de cette étude à la fois expérimentale et numérique multi-échelle est de mieux comprendre les effets souvent antagonistes et en partie couplés de l'oxygène et de l'hydrogène en solution sur le comportement viscoplastique du titane non-allié de phase alpha. Dans un premier volet, un scénario du vieillissement statique et dynamique dans le titane non-allié de phase alpha est proposé. La présence du pic de traction est attribuée à la ségrégation des atomes interstitiels d'oxygène sur les dislocations coin de vecteur de Burgers <c+a>. Dans le cas du vieillissement dynamique les instabilités observées, typiques de l'effet Portevin-Le Chatelier, sont associées à l'étalement du cœur non planaire des dislocations vis de vecteur de Burgers <a>. Une loi de comportement prenant en compte les effets liés aux interactions entre dislocations et atomes en solution a été développée. Le modèle de Kubin-Estrin-McCormick qui permet de prendre en compte l'effet du vieillissement a été étendu au cas de la plasticité cristalline. Les simulations par éléments finis ont été réalisées sur des agrégats polycristallins avec différents nombres de grains. Ensuite, les essais de fissuration (ténacité et rupture différée) ont été réalisés sur les matériaux bruts, et chargés en hydrogène. Enfin, des simulations numériques de la rupture de ces éprouvettes ont été réalisées pour toutes les conditions expérimentales testées en utilisant le modèle de comportement mécanique macroscopique identifié. Un modèle de zone cohésive a été développé pour la simulation de la propagation des fissures. / Widely used for aircraft or rocket engine manufacturing titanium and its alloys are prone to the room-temperature creep that leads to the phenomenon of sustained load subcritical crack growth. One of the major cause of such unusual viscoplastic behavior of titanium is the phenomena of static and dynamic strain aging which represents an interaction between dislocations and interstitial atoms of oxygen and hydrogen. The aim of the present experimental and numerical multiscale study is to investigate the influence of the interstitial hydrogen and oxygen on the viscoplastic behavior and the resistance to sustained load cracking in commercially pure titanium of phase alpha.In a first step, a scenario of static and dynamic strain aging was proposed. The presence of the stress peak was attributed to the segregation of interstitial atoms of oxygen on the edge <c+a> dislocations. In case of dynamic strain aging, the observed instabilities, typical for the Portevin-Le Chatelier effect, were associated with the non-planar core of screw <a>-type dislocations. The crystal plasticity was introduced into the phenomenological model in order to capture the strain aging phenomena and the anisotropy of the mechanical properties. The modeling approach for strain aging suggested by Kubin-Estrin-McCormick is based on the internal variable called the aging time which corresponds to the waiting time of a dislocation in a pinned state. Finite element simulations were then performed on the polycrystalline aggregates for different number of grains. At the next step, fracture toughness and sustained load cracking tests were performed on the material with different levels of hydrogen. Finally, numerical simulations of toughness and sustained load cracking tests using the identified viscoplastic model were carried out for all experimental conditions. A cohesive zone model was then introduced ahead of the crack tip to simulate crack propagation.
|