• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 93
  • 6
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 100
  • 100
  • 100
  • 72
  • 71
  • 63
  • 37
  • 28
  • 24
  • 24
  • 24
  • 17
  • 17
  • 17
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Tomografia de coerência óptica: medida da espessura do subcampo central no edema macular diabético / Optical coherence tomography: central subfield thickness measurement in diabetic macular edema

HONNOUCHE, Rosana Zacarias 29 November 2011 (has links)
Made available in DSpace on 2014-07-29T15:25:16Z (GMT). No. of bitstreams: 1 Tese Rosana Zacarias Honnouche.pdf: 1939926 bytes, checksum: d4fdb3cd4d741d0cf72b9b9269fceb63 (MD5) Previous issue date: 2011-11-29 / Diabetic macular edema (DME) is the main cause of visual loss in diabetic patients and is characterized by retinal thickening, whose evaluation is important for the diagnosis and management of diabetic retinopathy. The aim of this research was to measure the central subfield thickness (CST), the best-corrected visual acuity (BCVA) and the macular volume, and compare these data to those of diabetic patients without DME, using spectral-domain optical coherence tomography (SD-OCT), for quantitative analysis of DME.Two hundred patients with nonproliferative diabetic retinopathy (NPDR) were enrolled in a transversal study, from which 55 eyes with macular edema were detected by fundus biomicroscopy. Twenty seven diabetic patients without DME and with normal ophthalmological exam served as control group. Measurements of CST (main variable), BCVA and macular volume were taken, considering the variables age, gender, NPDR classification, external limitant membrane (ELM) integrity and type of DME. Biomicroscopy with noncontact lens, fluorescein angiography and spectral optical coherence tomography were performed using Cirrus SD-OCT. Besides descriptive statistics, additional tests were applied to analyze the results, such as variance analysis, t-Student, chisquare, Fischer s exact test, Mann-Whitney and Kruskall-Wallis. The relation between CST and BCVA was studied by linear regression, with logarithmic scale of minimal angle of resolution (logMAR). It was found that there is no significant difference between case and control groups for the variables age and gender. However, there was significant difference for variables CST, BCVA and macular volume. It was found significant correlation between retinopathy severity according to NPDR classification and the mean value of CST,which is the greater the retinopathy severity, the greater the CST. Most of the patients presented moderate NPDR. A strong correlation between macular volume and CST was found. Patients with serous retinal detachment presented higher mean value of CST, and those with CME presented worse BCVA. Patients with disrupted ELM showed greater mean value of CST and worse BCVA. It was concluded that SD-OCT allows quantitative measurement of CST in DME and, for identifying the retinal layers individually, also detects retinal structural changes and correlates them to visual functions. / O edema macular diabético é a principal causa de perda visual em diabéticos e é caracterizado pelo espessamento retiniano, cuja avaliação é importante para o diagnóstico e conduta da retinopatia diabética. O objetivo deste trabalho foi comparar as medidas da espessura do subcampo central (ESCC), a acuidade visual e o volume macular de pacientes com edema macular diabético (EMD) com diabéticos sem EMD, usando tomografia de coerência óptica de domínio espectral (SD-OCT) para análise quantitativa do EMD. Foi realizado um estudo transversal em que foram avaliados 55 pacientes com EMD, selecionados pela biomicroscopia de fundo, de um grupo de 200 pacientes com retinopatia diabética não proliferativa (RDNP). Um grupo de 27 pacientes diabéticos sem edema macular e com exame oftalmológico normal serviu como controle. Mediu-se a espessura do subcampo central (principal variável), a acuidade visual , o volume macular e avaliou-se a idade, o sexo, a classificação RDNP, a integridade da membrana limitante externa (MLE) e a morfologia do edema macular. Realizou-se biomicroscopia com lente de não contato, angiofluoresceinografia e tomografia de coerência óptica de domínio espectral com Cirrus SD-OCT. Além da estatística descritiva, utilizou-se testes para análise dos resultados: análise de variância, t-Student, qui-quadrado, teste exato de Fisher, Mann-Whitney e Kruskall-Wallis. A relação entre a ESCC e a acuidade visual foi estuda da através de análise de regressão linear com escala logarítmica de mínimo ângulo de resolução (logMAR). Registrou-se não haver diferença significativa entre casos e controles nas variáveis idade e sexo. Entretanto, houve diferença significativa para as variáveis ESCC, acuidade visual e volume macular. Foi encontrada correlação significativa entre a gravidade da retinopatia na classificação RDNP e a média da ESCC, sendo que quanto maior a gravidade da retinopatia, maior a ESCC. A maior parte dos pacientes apresentou RDNP moderada. Foi encontrada correlação significativa entre o volume e a ESCC. Pacientes com descolamento seroso apresentaram maior média da ESCC; e aqueles com EMC apresentaram pior acuidade visual. Pacientes com MLE descontínua apresentaram maior média da ESCC e pior acuidade visual. Concluiu-se que o SD-OCT mede quantitativamente a ESCC no EMD e, por identificar individualmente as camadas retinianas, detecta suas mudanças estruturais. Estas medidas podem ser correlacionadas com a função visual e auxiliar na conduta de pacientes com retinopatia diabética.
82

Comparação das medidas da espessura macular e da camada de fibras nervosas retiniana para detecção de atrofia em banda do nervo óptico através da tomografia de coerência óptica / Comparison of macular thickness and retinal nerve fiber thickness measurements for detection of band atrophy of the optic nerve using optical coherence tomography

Frederico Castelo Moura 31 August 2007 (has links)
Pacientes com compressão quiasmática apresentam perda das fibras nervosas da retina nasal que decussam no quiasma óptico. Por conseguinte, ocorre perda das fibras nervosas, predominantemente, no setor nasal e temporal do disco óptico, que se manifesta por atrofia em banda do nervo óptico ao exame oftalmoscópico e hemianopsia temporal ao exame de campo visual. Trabalhos anteriores mostraram que o tomógrafo de coerência óptica é capaz de diferenciar pacientes com atrofia em banda do nervo óptico associada à hemianopsia temporal completa de indivíduos normais através da análise da camada de fibras nervosas peripapilar. Estudos em glaucoma têm sugerido que a avaliação da espessura macular poderia ser útil na quantificação da perda neural como um método alternativo ou complementar ao estudo da camada de fibras nervosas da retina. No presente estudo, a espessura macular e da camada de fibras nervosas foram avaliadas pelo tomógrafo de coerência óptica em pacientes com atrofia em banda do nervo óptico e graus variados de hemianopsia temporal. O desempenho dos parâmetros maculares para detecção da atrofia em banda do nervo óptico foi avaliado pela área sob a curva ROC (AROC) e sensibilidades para especificidades fixas e os resultados foram comparados aos parâmetros da camada de fibras nervosas peripapilar. Para identificar os parâmetros do Stratus OCT que apresentaram melhor desempenho para diferenciar pacientes com AB do nervo óptico de indivíduos normais, modelos de regressão logística foram utilizados. A correlação estrutura-função foi realizada entre o grau do defeito temporal e os valores de espessura macular e da camada de fibras peripapilar através do coeficiente de correlação de Spearman. A categorização diagnóstica dos parâmetros da camada de fibras nervosas através do banco de dados normativos foi avaliada pelos valores de sensibilidade e especificidade calculados pelo teste exato de Fisher. Quarenta e quatro olhos com atrofia em banda e 47 olhos normais foram avaliados no estudo. Entre os parâmetros maculares, os parâmetros da retina nasal apresentaram melhor desempenho para detectar atrofia em banda do nervo óptico comparados aos parâmetros da retina temporal. Não houve diferença significante (p=0,32) entre as áreas sob a curva ROC do melhor parâmetro macular (AROC=0,97) e do melhor parâmetro da camada de fibras nervosas retiniana (AROC=0,99). Na avaliação da correlação estrutura-função, os parâmetros da retina nasal apresentaram maior correlação com o defeito campimétrico comparados aos parâmetros da camada de fibras nervosas da retinal. Entre os parâmetros maculares, a espessura nasal média apresentou a maior correlação (rs=0,618). Entre os parâmetros da camada de fibras nervosas da retina, a espessura média apresentou a maior correlação (rs=0,479). Os parâmetros espessura média, espessura nasal e espessura temporal da camada de fibras nervosas da retina apresentaram melhor desempenho diagnóstico baseado na categorização diagnóstica do banco de dados normativos. Os resultados obtidos no estudo mostraram que os parâmetros maculares discriminam olhos com atrofia em banda do nervo óptico em pacientes com graus variados de defeito temporal. Além disso, os parâmetros da retina nasal podem colaborar com o exame perimétrico e os parâmetros da camada de fibras nervosas para o seguimento dos pacientes com compressão quiasmática. / Patients with chiasmal compression present damage of crossed fibers of nasal retina. Therefore, retinal nerve fiber layer loss occurs predominantly on the nasal and temporal sides of the optic disc, a pattern that can be identified on ophthalmoscopy as band atrophy of the optic nerve and on visual field as temporal hemianopia. Previous studies have been demonstrated that optical coherence tomography is able to detect retinal nerve fiber layer loss in patients with lesions of the optic chiasm and complete temporal hemianopia. Studies in glaucoma have been suggested that macular thickness measurements could be useful in quantification of optical nerve axonal loss as alternative or complement method to evaluate the retinal nerve fiber layer. The purpose of the present study was to compare macular thickness and retinal nerve fiber thickness measurements in patients with band atrophy of the optic nerve and different severities of visual field defect using optical coherence tomography. Area under the receiver operating characteristic curve (AROC) and sensitivities at fixed specificities were performed for evaluation of diagnostic accuracy of macular and retinal nerve fiber layer parameters. To identify the best optical coherence tomography measurements to differentiate band atrophy of the optic nerve patients from normal individuals, logistic regression models were performed. Association between optical coherence tomography parameters and temporal field defect were examined by Spearman coefficient of correlation. Fisher\'s exact test was performed to evaluate diagnostic ability of retinal nerve fiber parameters by optical coherence tomography in eyes with band atrophy using comparison with its internal normative database. A total of 44 eyes with band atrophy of the optic nerve and 47 normal eyes were studied. Among macular parameters, nasal retina measurements showed diagnostic accuracy better than temporal retina measurements. No statistically significant difference (p=0.32) was found between areas under ROC curve for the best macular parameter (AROC=0.97) and the best retinal nerve fiber layer parameter (AROC=0.99). Nasal retina parameters correlations were higher than retinal nerve fiber parameters. The highest correlation was observed for the mean nasal thickness (rs=0.618) for macular parameters. In retinal nerve fiber parameters, the highest correlation was observed for the average thickness (rs=0.479). In evaluation of diagnostic ability of normative database, the average thickness parameter demonstrated the highest sensitivity for detection of abnormalities in eyes with band atrophy, followed by the parameters related to the nasal and temporal quadrants. These results suggest that macular thickness measurements discriminate eyes with band atrophy of the optic nerve with different severities of temporal field defect. Results also suggest that nasal retina thickness measurements could potentially be used to evaluate retinal ganglion cell loss in patients with chiasmal compression.
83

Estudo comparativo do diagnóstico de edema macular secundário a oclusão de ramo da veia central da retina pela biomicroscopia de mácula, angiofluoresceinografia e tomografia de coerência óptica / Comparison of optic coherence tomography, macular biomicroscopy and fluorescein angiography for macular edema secondary to branch retinal vein occlusion

Pinheiro, Alexandre Grobberio 04 October 2007 (has links)
As Oclusões Venosas da Retina são complicações do sistema vascular retiniano com grande potencial de impacto no sentido da visão. As oclusões Venosas são classificadas de acordo com a anatomia da região acometida e podem ser divididas em oclusão de ramo e da veia central da retina. O edema macular é a principal causa de baixa acuidade visual na Oclusão de Ramo da Veia Central da Retina (OVR). Sua detecção, localização e classificação são cruciais para a prevenção e tratamento da perda visual na OVR. A Biomicrospia Macular e a Angiofluoresceinografia são os métodos tradicionais de avaliação do edema macular na OVR, a Tomografia de Coerência Óptica (TCO) é uma tecnologia nova, que permite uma avaliação objetiva da morfologia macular. O objetivo primário do presente estudo foi avaliar, em uma mesma população, a acurácia dos métodos de diagnóstico do edema macular na OVR através da análise de três quesitos, aumento da espessura macular e da sua localização, presença de cistos intra-retinianos e a presença de descolamento seroso macular (DSM). Indivíduos com OVR foram selecionados com base nos achados fundoscópicos da doença e com tempo de história da doença entre três e vinte quatro meses. Todos os sujeitos foram submetidos a exames com o Stratus OCT (TCO), Angiofluoresceinografia digital (Angio) e o exame da biomicroscopia macular com lente de Volk de 78 D (BM) dentro do período de uma semana, além de exame oftalmológico completo. As medidas utilizadas para avaliação da acurácia diagnóstica foram o índice de concordância Kappa e a sensibilidade. Dos 32 indivíduos inicialmente avaliados, 8 foram posteriormente excluídos por não cumprirem os critérios de inclusão ou de exclusão, restando 24 indivíduos para análise. Na avaliação da espessura macular, a concordância entre BM e a TCO foi substancial e significante para a detecção do aumento da espessura macular com Kappa = 0,778 (p < 0,001) e a sensibilidade foi 95,5%. Na comparação entre a BM e a TCO para a detecção de cistos intra-retinianos, a concordância foi fraca com Kappa = 0,250 (p = 0,066) e a sensibilidade foi 57,9 %. A concordância entre a Angio e a TCO para os cistos foi pobre e não significante com Kappa = 0,124 (p = 0,237) e a sensibilidade foi 58,7 %. Houve uma correlação significante entre a presença de extravasamento na angiofluoresceinografia e a presença de cistos intra-retinianos na TCO (p=0,042). Na avaliação do DSM a concordância entre a BM e a TCO foi fraca com Kappa = 0,314 (p = 0,062) e a sensibilidade foi 60%, não houve concordância entre a Angio e a TCO para a detecção do DSM com Kappa = 0 e sensibilidade de 0%, e também não houve correlação significante entre a presença de descolamento seroso na TCO e a presença de extravasamento na angiofluoresceinografia (p=0,615). Os dados obtidos no presente estudo sugeriram que o Stratus OCT têm acurácia superior para a detecção dos cistos intra-retinianos e do descolamento seroso macular, se comparado à biomicroscopia macular e à angiofluoresceinografia / Retinal Vein Occlusions are complications of the retinal vascular system that can cause a great impact on vision. The Vein Occlusions are classified according to the anatomy of the affected region and can be categorized as: branch retinal vein occlusion and central retinal vein occlusion. Macular edema is the main cause for low visual acuity in Branch Retinal Vein Occlusion (BRVO). Its detection, location and classification are crucial for the prevention and treatment of vision loss in BRVO. Both Macular Biomicroscopy and Angiofluoresceinography are traditional methods for the evaluation of the macular edema in BRVO; the Optical Coherence Tomography (OCT) is a new technology that allows for an objective evaluation of macular morphology. The main objective of the present study was to evaluate, among the same population, the accuracy of the diagnostic methods of macular edema in BRVO through the analysis of three items: the increase of macular thickness and its location, the presence of intraretinal cysts, and the presence of serous macular detachment. Patients with BRVO were selected according to the fundoscopic findings of the disease and a disease history of three to twenty-four months. All of the individuals underwent exams with the Stratus OCT, digital Angiofluoresceinography (Angio) and a macular biomicroscopy with a 78D Volk lens (MB), within a period of one week, as well as a complete ophthalmologic exam. The parameters used in the evaluation of the diagnostic accuracy were sensitivity and the kappa coefficient. Of the 32 subjects who were initially evaluated, 8 were later excluded since they did not meet inclusion or exclusion criteria. The remaining 24 subjects were analyzed. In the evaluation of macular thickness, the concordance between the MB and the OCT was substantial and significant in the detection of the increase in macular thickness, with Kappa = 0.778 (p<0.001) and a sensitivity of 95.5%. When comparing the MB and the OCT in the detection of intraretinal cysts, the concordance was fair, with Kappa = 0.250 (p = 0.066) and a sensitivity of 57.9%. The concordance between the Angio and the OCT for cysts detection was poor and non significant, with Kappa = 0.124 (p = 0.237) and a sensitivity of 58.7%. There was a significant correlation between the presence of leakage in the angiofluoresceinography and the presence of intraretinal cysts in the OCT (p = 0.042). In the evaluation of the SMD, the concordance between the MB and the OCT was fair, with Kappa = 0.314 (p = 0.062) and a sensitivity of 60% an there was no concordance between the Angio and the OCT in the detection of SMD, with Kappa = 0 and sensitivity of 0%. There was also no significant correlation between the presence of serous detachment in the OCT and the presence of leakage in the angiofluoresceinography (p = 0.615). The results obtained in the present study suggest that Stratus OCT is more accurate to the detection of intraretinal cysts and serous macular detachment than macular biomicroscopy with a 78D Volk lens, and by angiofluoresceinography
84

Efeitos do acetonido de triancinolona associado à panfotocoagulação na retinopatia diabética proliferativa / Effects of triamcinolone acetonide associated with panretinal photocoagulation in proliferative diabetic retinopahty

Maia Júnior, Otacílio de Oliveira 29 February 2008 (has links)
INTRODUÇÃO: O tratamento padrão estabelecido pelo Early Treatment Diabetic Retinopathy Study (ETDRS) para retinopatia diabética proliferativa (RDP), com ou sem edema macular clinicamente significativo (EMCS), é a panfotocoagulação com laser. Essa forma de tratamento reduz o risco de perda visual, mas não proporciona ganho de visão. O objetivo deste estudo é avaliar os efeitos do acetonido de triancinolona associado à panfotocoagulação na RDP. MÉTODOS: Realizou-se um ensaio clínico randomizado, prospectivo e aberto com portadores de RDP bilateral e simétrica, submetidos à panfotocoagulação com laser em ambos os olhos. Portadores de EMCS foram tratados com fotocoagulação focal na região macular no primeiro episódio da panfotocoagulação. A injeção intravítrea de acetonido de triancinolona (4 mg/0,1 ml) foi administrada aleatoriamente em um dos olhos (grupo estudo), após último episódio da laserterapia, e o contralateral foi adotado para comparação (grupo controle), sendo seguidos por 6 meses. Os parâmetros adotados para avaliar os efeitos terapêuticos foram: acuidade visual com melhor correção óptica (tabela do ETDRS), medidas de espessura central e de volume macular por meio da tomografia de coerência óptica e taxa de sangramento (hemorragia pré-retiniana ou vítrea). As potenciais complicações da droga foram avaliadas durante o seguimento (pressão intra-ocular, catarata, endoftalmite e pseudo-endoftalmite). RESULTADOS: Foram incluídos 28 (vinte e oito) indivíduos com diabetes melito tipo 2. Quanto ao EMCS, 22 olhos apresentaram no grupo estudo e 23, no grupo controle (p= 0,317). A média de idade foi de 61,36 ± 5,77 anos, com predominância do sexo ferminino (57,1%). A maioria era portadora de hipertensão arterial sistêmica (82,1%) e usuária de insulina (75,0%). Não houve diferença significante nas médias de número de disparos da panfotocoagulação e da fotocoagulação na região macular entre os grupos. Quanto à acuidade visual, o grupo estudo apresentou pior acuidade antes do tratamento em relação ao grupo controle (p= 0,040), não havendo diferença significativa na primeira semana do tratamento. Durante o seguimento, o grupo estudo evoluiu com melhora na acuidade visual no primeiro (p< 0,001), no terceiro (p< 0,001) e no sexto meses (p< 0,001) em relação ao controle. Em relação às medidas de espessura central e de volume macular, os grupos não apresentaram diferença significativa antes do tratamento, no entanto, o grupo estudo apresentou medidas significativamente menores na primeira semana, no primeiro, no terceiro e no sexto meses em relação ao controle. Quanto à taxa de sangramento, 9 olhos (32,1%) do grupo controle evoluíram com sangramento e nenhum do grupo estudo (p< 0,001). Os grupos apresentaram diferença na pressão intra-ocular apenas na primeira semana do tratamento, quando as medidas do grupo estudo foram maiores que as do controle (p< 0,05). Nenhum dos olhos apresentou catarata com indicação cirúrgica, endoftalmite ou pseudo-endoftalmite. CONCLUSÃO: Os resultados deste estudo sugerem que a injeção intravítrea de triancinolona é um procedimento seguro e pode melhorar o prognóstico funcional e estrutural da mácula em olhos com RDP submetidos a panfotocoagulação com laser. / INTRODUCTION: The gold standard treatment for proliferative diabetic retinopahty (PDR) with and without clinically significant macular edema (CSME), as stablished by the Early Treatment Diabetic Retinopathy Study (ETDRS), is panretinal photocoagulation (PRP). This treatment lowers the rate of severe vision loss, but does not increase vision. The aim of this study is to evaluate the efficacy and safety of triamcinolone acetonide associated to PRP for the management of PDR. METHOD: This is a prospective, randomized clinical trial for patients with bilateral and symmetrical PDR who had undergone PRP in both eyes. Patients who had CSME were treated with macular focal photocoagulation on the first episode of the PRP. Intravitreal injection of triamcinolone acetonide (4 mg/0.1 ml) was given to the study eye after the last episode of PRP and the fellow eye was used as control. Follow up was 6 months long. Best-corrected visual acuity (BCVA) using ETDRS charts, central macular thickness and macular volume as measured by the optical coherence tomography software, and the amount of bleeding (both preretinal and vitreous) were the parameters chosen to analyse outcome. Side effects of triamcinolone acetonide such as intraocular pressure, cataracts and severe inflammation, were also followed during the study. RESULTS: Twenty eight diabetes type 2 patients were included. Twenty two study eyes and 23 fellow eyes (controls) presented with CSME (p= 0.317). Mean age was 61.36 ± 5.77 years, with 57.1% females. Many patients had hypertension (82.1%) and used insulin (75.0%). There was no significant difference on the number of spots used for PRP or macular photocoagulation in between the groups. The study eyes had lower BCVA on baseline than the control eyes (p= 0.040). One week after the treatment, there was no difference on BCVA between the study and control eyes. During the follow up, the study group increased their BCVA on the first (p< 0.001), third (p< 0.001) and sixth month (p< 0.001) compared to control. Even thought there was no significant difference on central macular thickness and macular volume between groups on baseline, the study eyes had significant lower measurements on the first week and first, third and sixth months in comparison to controls. Nine control eyes (32.1%) had hemorrhages and none study eyes (p< 0.001). Injected eyes had higher intraocular pressure than controls on the first week of treatment (p< 0.05). None of the eyes developed cataracts that needed surgery, endophthalmits or severe inflammation. CONCLUSION: This study suggests intravitreal injection of triamcinolone is a safe procedure that increases funcional and anatomical prognosis of the macula in PDR eyes that underwent PRP.
85

Sensor ótico heterogêneo aplicado na análise de polímeros

Saccon, Fernando Antonio Moura 25 July 2014 (has links)
CAPES; CNPq; Fundação Araucária / Esta tese de doutorado apresenta um sistema de monitoração heterogêneo para a caracterização do processo de secagem e cura de filmes poliméricos e resina odontológica. Essa caracterização é de suma importância para aperfeiçoar o processo de fabricação e a escolha das matérias-primas dos mesmos, uma vez que parâmetros como a variação da espessura e a deformação mecânica no material estão diretamente ligadas à sua qualidade e durabilidade. O sensor heterogêneo emprega técnicas complementares para a quantificação de múltiplos parâmetros físicos, visando a compreensão das etapas que acontecem durante o processo de secagem e cura. Os ensaios se deram em períodos de 24 horas analisando amostras de tinta e verniz acrílicos e resina dentária. Foram quantificadas deformações longitudinais, variação de massa, espessura e índice de refração médio. Nas amostras de tinta e verniz acrílicos, obteve-se redução entre 60% e 70% no valor inicial da espessura, enquanto o comportamento do índice de refração do verniz foi associado às diferentes etapas do processo de secagem. As amostras de resina odontológica apresentaram redução da espessura menor que 5% em todos os ensaios realizados, percentual semelhante à variação do índice de refração. Todavia, as redes de Bragg identificaram um aumento de temperatura da resina odontológica de aproximadamente 20°C durante a fotoativação. A flexibilidade do sistema sensor heterogêneo demonstrado permite a análise do processo de secagem ou cura de uma ampla gama de filmes poliméricos e resinas, sem a necessidade de adaptações significativas no arranjo experimental. Com uma caracterização correta das etapas envolvidas na secagem ou cura, todo o processo que vai desde a formulação do produto à aplicação final pode ser otimizado, levando à melhoria da relação custo-benefício para cada aplicação pretendida. / This thesis presents a heterogeneous system to characterize the drying and curing process of polymer films and dental resin. This characterization is important to improve the manufacturing process and the choice of the raw materials, since parameters such as thickness variation and the mechanical deformation in the material are directly related to their quality and durability. The sensor employs heterogeneous complementary techniques for the quantification of multiple physical parameters, aimed to understand the steps that occur during drying and curing. The tests took place in periods of 24 hours analyzing samples of both acrylic paint and varnish, as well as dental resin. Longitudinal deformation, mass variation, thickness and mean refractive index were quantified. In samples of acrylic paint and varnish, a reduction between 60% and 70% in the initial value of the thickness was obtained, while the behavior of the refractive index of the varnish was associated with the different stages of the drying process. Samples of dental resin presented thickness decreasing less than 5% in all tests, percentage similar to the variation of the refractive index. However, fiber Bragg gratings have identified a temperature increase of the dental resin about 20 ° C during the polymerization. The flexibility of the heterogeneous sensor system demonstrated allows the analysis of drying or cure processes of a great variety of polymer films and resins, without the need for important changes in the experimental setup. With the correct characterization of the stages involved in the drying or cure, the whole process from the product formulation to the final application may result in an optimized and cost effective product for any intended application.
86

"Análise comparativa das medidas de espessura da camada de fibras nervosas da retina de pacientes com atrofia em banda do nervo óptico e de indivíduos normais através da tomografia de coerência óptica e da polarimetria a laser" / A comparative analysis of the retinal nerve fiber layer thickness measurements in patients with band atrophy of the optic nerve and in normal controls using optical coherence tomography and scanning laser polarimetry

Bruno Campêlo Leal 07 July 2006 (has links)
As afecções que acometem a via óptica anterior podem acarretar perda de fibras das células ganglionares retinianas, gerando alterações na camada de fibras nervosas da retina (CFNR). O objetivo deste trabalho foi o de comparar a capacidade da tomografia de coerência óptica (OCT-1), do OCT 3 (Stratus OCT) e do polarímetro de varredura a laser (GDx) em diferenciar olhos normais de olhos com atrofia em banda do nervo óptico e hemianopsia temporal, assim como, comparar o desempenho de tais tecnologias entre si. Foram estudados 37 indivíduos num total de 46 olhos divididos igualmente em dois grupos. O Stratus OCT, o OCT 1 e o GDx se mostraram capazes de identificar corretamente a redução global (average) da espessura da CFNR dos indivíduos com AB comparados com uma população normal. Observamos uma melhora progressiva das sensibilidades/especificidades e das AROC, com o desempenho melhor do OCT1 sobre o GDx e do Stratus OCT sobre o OCT 1 / Most diseases that affect the optic pathways present clinically with loss of one or more visual functions.When optic pathway injuries involve the anterior visual pathways they may cause loss of the retinal nerve fiber layer (RNFL) and "band atrophy" (BA). The purpose of this study was therefore to compare the ability of the optical coherence tomography (OCT) 1, the OCT 3 (Stratus OCT) and the scanning laser polarimetry (GDx) to differentiate normal eyes from eyes with BA of the optic nerve and temporal hemianopsia. Thirty-seven individuals in a total of 46 eyes divided equally in two groups were studied. Each one of the parameters, except the values from the nasal quadrant measured by the GDx, showed statistically significant difference when we compare normal patients with the BA group. The study also showed a gradual improvement of the sensibilities/specificities and of the AROC, with a better performance of the OCT1 compared to GDx and of the Stratus OCT compared to the OCT 1
87

Potencial evocado visual multifocal em olhos com hemianopsia temporal por compressão quiasmática. Correlação com a perimetria computadorizada e a tomografia de coerência óptica / Multifocal visual evoked potential in eyes with temporal hemianopia from chiasmal compression. Correlation with standard automated perimetry and OCT findings

Rafael Miranda Sousa 05 May 2017 (has links)
OBJETIVO: Avaliar a capacidade do potencial visual evocado multifocal (PEV-mf) em diferenciar pacientes portadores de hemianopsia temporal de controles normais e avaliar a correlação entre o PEV-mf, o campo visual (CV) realizado com a perimetria automatizada e a tomografia de coerência óptica de domínio fourier (TCO-dF). MÉTODOS: Vinte sete olhos de 21 pacientes com defeito de campo visual temporal secundário a compressão quiasmática e 43 olhos de 23 controles normais foram submetidos aos exames PEV-mf, CV e TCO-dF (3D OCT-1000®, Topcon) da mácula e da camada de fibras nervosas da retina (CFNR). Foi calculada a média das respostas do PEV-mf global, do PEV-mf central e a média de espessura do TCO-dF da mácula para cada quadrante e para cada hemicampo, enquanto a espessura da CFNR foi dividida em 12 setores ao redor do nervo óptico. A perda de CV foi calculada para os quatro quadrantes e para os hemicampos temporal e nasal no CV 24-2 e CV 10-2. Os dois grupos foram comparados utilizando equações de estimativas generalizadas (GEE) e as correlações entre o PEV-mf, CV e o TCO-dF foram calculadas. RESULTADOS: As médias das amplitude P1 e N2 do PEV-mf global e central para os hemicampos e os quadrantes temporais foram significativamente menores nos pacientes que nos controles (p < 0.004). Não houve diferença estatística entre os grupos para os parâmetros de amplitudes do PEV-mf nos setores nasais. Não houve diferença estatística nas médias das latências do PEV-mf global e central entre os pacientes e os controles normais. Foi encontrada correlação moderada, estatisticamente significativa, entre os parâmetros de amplitudes temporais do PEV-mf - global e central com a perda de CV 24-2 e 10-2 temporal, assim como com as medidas de espessura macular e da espessura CFNR na TCO-dF. CONCLUSÕES: As médias das amplitudes do PEV-mf foram capazes de diferenciar olhos de pacientes com hemianopsia dos controles normais e apresentaram correlação significativa com os dados obtidos pela perimetria automatizada e pelo TCO-dF. Estes dados sugerem que o PEV-mf global e central podem ser utilizados na detecção de anormalidades do campo visual em pacientes portadores de compressão quiasmática / PURPOSE: To evaluate the ability of multifocal visual evoked potential (mfVEP) to differentiate patients with temporal hemianopia due to chiasmal compression from normal controls. To assess the relationship between mfVEP, standard automated perimetry (SAP) and fourier domain-optical coherence tomography (fd-OCT). METHODS: Twenty-seven eyes of 21 patients with permanent temporal visual field (VF) defects from chiasmal compression and 43 eyes of 23 healthy controls underwent mfVEP, SAP and fd-OCT (3D OCT-1000®, Topcon) macular and peripapillary retinal nerve fiber layer (RNFL) measurements. It was averaged the responses for global mfVEP, central mfVEP and fd-OCT macular measurements were averaged in quadrants and halves, while peripapillary RNFL thickness was averaged in 12 sectors around the disc. VF loss was estimated in four quadrants and each half of 24-2 and 10-2 strategy test points. The two groups were compared using generalized estimated equations (GEE). Correlations between mfVEP, VF and fd-OCT findings were verified. RESULTS: Global and central mfVEP P1 and N2 amplitude parameters of temporal measurements were significantly smaller in patients than controls (p < 0.004). No significant differences were observed between the groups with respect to mfVEP amplitude parameters from the nasal measurements. No significant differences were observed in global and central mfVEP latency parameters for all averaged measurements between patients and healthy controls. A significant moderate correlation was found between global and central mfVEP amplitude parameters of temporal measurements and temporal VF 24-2 and 10-2 loss as well as with corresponding fd-OCT macular and RNFL thickness measurements. CONCLUSIONS: mfVEP amplitude parameters were able to differentiate eyes with temporal hemianopia from controls and were significant correlated with VF and fd-OCT findings. These data suggest that it is a useful technology for detecting visual abnormalities in patients with chiasmal compression
88

Estudo comparativo do diagnóstico de edema macular secundário a oclusão de ramo da veia central da retina pela biomicroscopia de mácula, angiofluoresceinografia e tomografia de coerência óptica / Comparison of optic coherence tomography, macular biomicroscopy and fluorescein angiography for macular edema secondary to branch retinal vein occlusion

Alexandre Grobberio Pinheiro 04 October 2007 (has links)
As Oclusões Venosas da Retina são complicações do sistema vascular retiniano com grande potencial de impacto no sentido da visão. As oclusões Venosas são classificadas de acordo com a anatomia da região acometida e podem ser divididas em oclusão de ramo e da veia central da retina. O edema macular é a principal causa de baixa acuidade visual na Oclusão de Ramo da Veia Central da Retina (OVR). Sua detecção, localização e classificação são cruciais para a prevenção e tratamento da perda visual na OVR. A Biomicrospia Macular e a Angiofluoresceinografia são os métodos tradicionais de avaliação do edema macular na OVR, a Tomografia de Coerência Óptica (TCO) é uma tecnologia nova, que permite uma avaliação objetiva da morfologia macular. O objetivo primário do presente estudo foi avaliar, em uma mesma população, a acurácia dos métodos de diagnóstico do edema macular na OVR através da análise de três quesitos, aumento da espessura macular e da sua localização, presença de cistos intra-retinianos e a presença de descolamento seroso macular (DSM). Indivíduos com OVR foram selecionados com base nos achados fundoscópicos da doença e com tempo de história da doença entre três e vinte quatro meses. Todos os sujeitos foram submetidos a exames com o Stratus OCT (TCO), Angiofluoresceinografia digital (Angio) e o exame da biomicroscopia macular com lente de Volk de 78 D (BM) dentro do período de uma semana, além de exame oftalmológico completo. As medidas utilizadas para avaliação da acurácia diagnóstica foram o índice de concordância Kappa e a sensibilidade. Dos 32 indivíduos inicialmente avaliados, 8 foram posteriormente excluídos por não cumprirem os critérios de inclusão ou de exclusão, restando 24 indivíduos para análise. Na avaliação da espessura macular, a concordância entre BM e a TCO foi substancial e significante para a detecção do aumento da espessura macular com Kappa = 0,778 (p < 0,001) e a sensibilidade foi 95,5%. Na comparação entre a BM e a TCO para a detecção de cistos intra-retinianos, a concordância foi fraca com Kappa = 0,250 (p = 0,066) e a sensibilidade foi 57,9 %. A concordância entre a Angio e a TCO para os cistos foi pobre e não significante com Kappa = 0,124 (p = 0,237) e a sensibilidade foi 58,7 %. Houve uma correlação significante entre a presença de extravasamento na angiofluoresceinografia e a presença de cistos intra-retinianos na TCO (p=0,042). Na avaliação do DSM a concordância entre a BM e a TCO foi fraca com Kappa = 0,314 (p = 0,062) e a sensibilidade foi 60%, não houve concordância entre a Angio e a TCO para a detecção do DSM com Kappa = 0 e sensibilidade de 0%, e também não houve correlação significante entre a presença de descolamento seroso na TCO e a presença de extravasamento na angiofluoresceinografia (p=0,615). Os dados obtidos no presente estudo sugeriram que o Stratus OCT têm acurácia superior para a detecção dos cistos intra-retinianos e do descolamento seroso macular, se comparado à biomicroscopia macular e à angiofluoresceinografia / Retinal Vein Occlusions are complications of the retinal vascular system that can cause a great impact on vision. The Vein Occlusions are classified according to the anatomy of the affected region and can be categorized as: branch retinal vein occlusion and central retinal vein occlusion. Macular edema is the main cause for low visual acuity in Branch Retinal Vein Occlusion (BRVO). Its detection, location and classification are crucial for the prevention and treatment of vision loss in BRVO. Both Macular Biomicroscopy and Angiofluoresceinography are traditional methods for the evaluation of the macular edema in BRVO; the Optical Coherence Tomography (OCT) is a new technology that allows for an objective evaluation of macular morphology. The main objective of the present study was to evaluate, among the same population, the accuracy of the diagnostic methods of macular edema in BRVO through the analysis of three items: the increase of macular thickness and its location, the presence of intraretinal cysts, and the presence of serous macular detachment. Patients with BRVO were selected according to the fundoscopic findings of the disease and a disease history of three to twenty-four months. All of the individuals underwent exams with the Stratus OCT, digital Angiofluoresceinography (Angio) and a macular biomicroscopy with a 78D Volk lens (MB), within a period of one week, as well as a complete ophthalmologic exam. The parameters used in the evaluation of the diagnostic accuracy were sensitivity and the kappa coefficient. Of the 32 subjects who were initially evaluated, 8 were later excluded since they did not meet inclusion or exclusion criteria. The remaining 24 subjects were analyzed. In the evaluation of macular thickness, the concordance between the MB and the OCT was substantial and significant in the detection of the increase in macular thickness, with Kappa = 0.778 (p<0.001) and a sensitivity of 95.5%. When comparing the MB and the OCT in the detection of intraretinal cysts, the concordance was fair, with Kappa = 0.250 (p = 0.066) and a sensitivity of 57.9%. The concordance between the Angio and the OCT for cysts detection was poor and non significant, with Kappa = 0.124 (p = 0.237) and a sensitivity of 58.7%. There was a significant correlation between the presence of leakage in the angiofluoresceinography and the presence of intraretinal cysts in the OCT (p = 0.042). In the evaluation of the SMD, the concordance between the MB and the OCT was fair, with Kappa = 0.314 (p = 0.062) and a sensitivity of 60% an there was no concordance between the Angio and the OCT in the detection of SMD, with Kappa = 0 and sensitivity of 0%. There was also no significant correlation between the presence of serous detachment in the OCT and the presence of leakage in the angiofluoresceinography (p = 0.615). The results obtained in the present study suggest that Stratus OCT is more accurate to the detection of intraretinal cysts and serous macular detachment than macular biomicroscopy with a 78D Volk lens, and by angiofluoresceinography
89

Correlação entre as espessuras da mácula e da camada de fibras nervosas da retina, medidas pelas tomografias de coerência óptica de dominio Fourier e de domínio do tempo, e a perimetria automatizada na atrofia em banda do nervo óptico / Correlation between macular and retinal nerve fiber layer Fourier domain and time domain optical coherence tomography measurements and visual field loss in band atrophy of the optic nerve

Luciana Virginia Ferreira Costa Cunha 18 April 2011 (has links)
OBJETIVO: Investigar a correlação entre as espessuras da mácula e da camada de fibras nervosas da retina (CFNR), medidas pelas tomografias de coerência óptica de domínio Fourier (FD - OCT) e de domínio do tempo (TD - OCT) e a perda de sensibilidade no campo visual (CV) em pacientes com atrofia em banda do nervo óptico. Comparar a habilidade diagnóstica dos dois instrumentos. MÉTODOS: 36 olhos de 36 pacientes com perda de CV permanente por compressão do quiasma óptico e 36 controles normais foram submetidos ao exame de CV pela perimetria automatizada padrão (Humphrey Field Analyzer TM; Carl Zeiss Meditec, Dublin, CA), ao FD - OCT (3 D OCT-1000TM Topcon Corp., Tokyo, Japan) e ao TD - OCT (StratusTM ;Carl Zeiss Meditec Inc, Dublin, California, USA). Foram comparados os protocolos análogos de ambos os equipamentos para avaliação da espessura macular.Foi realizado a divisão macular em quatro quadrantes e em metades, sendo calculado a média da espessura macular global, a média da espessura dos quadrantes e a média da espessura das metades maculares. A média global e setorial da medida da espessura da CFNR peripapilar também foi analisada. A perda de sensibilidade no CV foi inicialmente avaliada pelo defeito temporal médio. O CV foi ainda dividido em 6 setores de acordo com a distribuição da CFNR e em 16 pontos centrais para a realização da correlação estrutura-função entre os parâmetros medidos pelo FD - OCT e a perda de sensibilidade no CV em decibéis e 1/Lambert. Foi calculado o coeficiente de correlação de Sperman e a análise de regressão linear. As áreas sobre a curva ROC e valores fixos de sensibilidade e especificidade foram calculados para cada parâmetro estudado. RESULTADOS: As medidas da espessura macular e da CFNR pelo FD - OCT e TD - OCT foram capazes de discriminar olhos com atrofia em banda do nervo óptico dos controles normais. A espessura global e setorial dos parâmetros maculares e da CFNR mostraram diferenças significativas (p<0,001) entre os doentes e os controles e os dois aparelhos tiveram desempenho semelhante na discriminação entre pacientes e controles. Em ambos existiram correlações significativas entre a perda de sensibilidade do CV e as medidas da espessura macular e da CFNR. As medidas de espessura nos quadrantes e nas metades nasais da macula, avaliadas pelo FD - OCT tiveram os melhores desempenhos nas correlações com os defeitos de CV, sendo o parâmetro com a melhor correlação, a medida do quadrante infero-nasal da mácula e a perda de sensibilidade do CV central do quadrante temporal superior central (r = 0.78, R2 = 61%, p<0,001). CONCLUSÕES: A espessura macular e a espessura da CFNR medidas pelo FD - OCT e pelo TD - OCT se correlacionaram topograficamente com a perda de sensibilidade no CV de pacientes com hemianopsia temporal por compressäo quiasmática. A correlação entre os quadrantes maculares e a perda de sensibilidade no CV, foram melhores do que aquelas entre o CV e as medidas da CFNR, principalmente nas medidas realizadas pelo FD - OCT. Este estudo demonstrou a importância clínica das medidas maculares na correlação estrutura-função e na quantificaçäo do dano neural em pacientes com compressão quiasmática, podendo ser útil na monitorização destes pacientes / PURPOSE: To investigate the relationship between fourier-domain optical coherence tomography (FD - OCT) measured macular and retinal nerve fiber layer thickness (RNFL) and visual field sensitivity loss on standard automated perimetry in eyes with permanent temporal hemianopia from chiasmal compression and compare the ability of FD - OCT and time-domain optical coherence tomography (TD - OCT) to detect axonal loss in eyes with band atrophy of the optic nerve. METHODS: One eye of each of 36 patients with permanent temporal visual field defects and 36 age- and sex-matched healthy subjects. Subjects underwent standard automated perimetry and macular and RNFL thickness measurements with FD - OCT (3 D OCT-1000® Topcon Corp., Tokyo, Japan) and TD - OCT (Stratus; Carl Zeiss Meditec Inc, Dublin, California, USA). Macular thickness measurements as a global average, divided in four quadrants and in two halves as well as average and sectoral RNFL thickness around the optic disc were calculated. Visual field sensitivity loss was evaluated by the temporal mean defect; as deviations from normal in six sectors of the visual field and in 16 central visual field test points. Relationship between visual field sensitivity loss in decibel and 1/Lambert units and optical coherence tomography measurements were evaluated using Spearman correlation coefficients and by linear regression analysis. Receiver operating characteristic curves and sensitivities at fixed specificities were calculated for each parameter. RESULTS: Global and sectoral macular and RNFL thickness parameters showed a significant difference in eyes with band atrophy compared with controls. The strongest correlations were seen between visual field sensitivity loss and quadrantic or hemianopic nasal macular thickness measurements than with sectoral retinal nerve fiber layer thickness measurements. The highest correlation was observed between the inferonasal quadrant macular thickness and the visual field sensitivity loss in the superior temporal central visual field quadrant (r = 0.78, R2 = 61%, p <0.001). CONCLUSION: Both RNFL thickness and macular thickness FD - OCT and TD - OCT measurements were related topographically with visual field sensitivity loss in patients with temporal hemianopia from chiasmal compression and there is a stronger relationship in quadrantic macular compared to RNFL thickness measurements with FD - OCT. Macular thickness measurements could potentially be used to quantify neuronal loss in patients with chiasmal compression and could prove clinically useful for detection of damage and for monitoring these patients
90

Avaliação oftalmológica e psicofísica do sistema visual de portadores de albinismo / Ophthalmologic and psychophysical evaluation of the visual system of individuals with albinism

Ronaldo Yuiti Sano 21 September 2017 (has links)
O albinismo e uma alteracao genetica rara que compromete a producao de melanina. As alteracoes clinicas consistem na falta de pigmentacao da pele, cabelo e pelos. Apresenta alteracoes oftalmologicas importantes, que comprometem a acuidade visual de forma severa, na grande maioria dos casos. As alteracoes oftalmologicas sao, ametropias, nistagmo, rarefacao do epitelio pigmentado da iris e da retina, hipoplasia foveal e decussacao anomala do nervo optico. Este estudo foi dividido em tres diferentes partes com os seguintes objetivos principais: Parte 1: Analise comparativa entre o grau de transparencia da iris (GTI), o grau de transparencia da retina (GTR) e a espessura da regiao macular com a acuidade visual nos pacientes com albinismo. Parte 2: Teste de sensibilidade ao contraste espacial de luminancia e ofuscamento com lentes de contato filtrantes em ambientes claros e escuros. Parte 3: Avaliacao da visao de cores, utilizando\\se o teste de Pranchas de Ishihara e o Cambridge Color Test (CCT). Material\' e\' Métodos: Participaram do estudo 121 individuos albinos, com idade media de 31,18 (} 15,47) anos, o que totalizou 242 olhos. Os participantes foram divididos em diferentes grupos nas tres partes do estudo, alguns participaram de uma ou mais partes. Na primeira parte os participantes foram submetidos a consulta oftalmologica, classificacao do grau de transparencia da iris e da retina em uma nova classificacao baseada em quatro diferentes graus de transparencia, alem de avaliacao foveal pelo exame de Tomografia de Coerencia Optica (OCT). Na segunda parte, os participantes foram submetidos ao teste de contraste computadorizado, utilizando lentes de contato filtrante e transparentes, em ambientes claros e escuros. Nesta etapa foi avaliada a influencia da lente filtrante na sensibilidade de contraste visual dos individuos com albinismo. Na terceira parte, os participantes foram submetidos aos testes de Pranchas de Ishihara e de Cambridge Colour Test (CCT), para avaliacao da visao de cores nos pacientes albinos. Resultados: Os resultados foram os seguintes: Parte\'1: A correlacao entre AV logMAR e GTI foi positiva (+0,569) e significativa (p<0,001). A correlacao entre AV logMAR e GTR foi positiva (+0,531) e significativa (p<0,001). A correlacao entre AV logMAR e a espessura macular nao foi significativa (p=0,105). A correlacao entre GTI e GTR foi positiva (+ 0,627) e significativa (p<0,001). A correlacao entre espessura macular e GTI nao foi significativa (p=0,397). A correlacao entre espessura macular e GTR nao foi significativa (p=0,458). Parte 2: Houve melhora estatisticamente significante da sensibilidade ao contraste com as lentes filtrantes em relacao as lentes transparentes no ambiente de ofuscamento (claro), na frequencia de 0,3 cpg, 0,6 cpg e 1,0 cpg (ciclos por grau). Nao houve melhora significante nas frequencia 2,0 cpg e 4,0 cpg. Nao houve melhora estatisticamente significante da sensibilidade ao contraste de lentes filtrantes em relacao as lentes transparentes no ambiente escuro (penumbra) em nenhuma das frequencias espaciais estudadas. Parte\' 3: Todos os individuos com albinismo nao apresentaram nenhuma alteracao de visao de cores no teste de Pranchas de Ishihara. O CCT demonstrou piora no limiar de deteccao de cores significativa nos eixos protan (p=0,021) e deutan (p=0,017), mas nao houve diferenca no eixo tritan (p=0,212). Os testes estatisticos sugerem que uma amostra maior seja estudada para validacao dos resultados / Albinism is a rare genetic alteration that compromises the production of melanine in all body tissues. The clinical alterations are the lack of pigment in the skin and hair. It presents important ophthalmological changes that compromise the visual acuity, in most cases. The ophthalmological changes are: ametropia, nystagmus, iris pigmented epithelium rarefaction, retina pigmented epithelium rarefaction, foveal hipoplasia and abnormal optic nerve decussation. This study has been divided in three different parts and had the following main objectives: Part 1, comparative analysis of the iris transparency degree (ITD), the retina transparency degree (RTD) and macular thickness with the visual acuity in albino patients. Part 2: Spatial contrast sensitivity test of luminance and outshine wearing contact lenses with filters in light and dark environments. Part 3: color vision evaluation using the Ishihara Test and the Cambridge Color Test (CCT). For the study 121 individuals with albinism were included with an average of 31,18 years old } 15,47, a total of 242 eyes. The participants were divided in different groups in the three parts of the study, some participated in one or more parts. In the first part the participants have been through an ophthalmological exam, classification of the iris transparency degree (ITD) and the retinal transparency degree (RTD) by a new classification based in 4 different degrees of transparency. Foveal evaluation by the Optic Coherence Tomography exam (OCT) was made in the first part of this study. In the second part, the participants have been submitted to the computerized contrast test, using filtered and transparent contact lenses in light and dark environments. In this part the influence of the filtering lenses in the visual contrast sensitivity in the albinism patients has been evaluated. In the third part, the participants have been submitted to Ishihara Test and Cambridge Color Test in order to evaluate the color vision in albino patients. The results are as follows: Part\' 1: the correlation between visual acuity in Logarithm of the Minimum Angle of Resolution (logMAR) and ITD was positive (+0,569) and significant (p<0,001). The correlation between visual acuity in logMAR and RTD was positive (+0,531) and significant (p<0,001). The correlation between visual acuity in logMAR and the macular thickness was not significant (p=0,105). The correlation between ITD and RTD was positive (+ 0,627) and significant (p<0,001). The correlation between the macular thickness and the ITD was not significant (p=0,397). The correlation between the macular thickness and the RTD was not significant (p=0,458). Part\'2: There has been a statistically significant improvement of the contrast sensitivity wearing the filtering lenses in relation to the transparent ones in bright environment, in the frequencies of 0,3 cycles per degree (cpd), 0,6 cpd and 1,0 cpd. There has been no significant improvement in the frequencies 2,0 cpd and 4,0 cpd. There has been no statistically significant improvement in contrast sensitivity wearing the filtering lenses in relation to the transparent one in the dark environment (shadow) in any of the spatial frequencies studied. Part\' 3: all albinism patients did not present any color vision change in the Ishihara Test. The CCT has shown a worsening in the color detection threshold in the protan axis (p=0,021) and deutan axis (p=0,017), but there has been no difference in the tritan axis (p=0,212). The statistic tests show that a bigger sample is recommended to confirm part 3 results

Page generated in 0.0896 seconds