• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 89
  • 48
  • 8
  • 3
  • 3
  • 2
  • Tagged with
  • 156
  • 156
  • 147
  • 142
  • 91
  • 89
  • 88
  • 78
  • 26
  • 19
  • 19
  • 19
  • 16
  • 15
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

On an operator associated to a restricted x-ray transform /

Lan, Ih-Ren. January 1999 (has links)
Thesis (Ph. D.)--Oregon State University, 2000. / Typescript (photocopy). Includes bibliographical references (leaves 77-78). Also available on the World Wide Web.
2

Evaluation of X-ray imaging to investigate hydraulic performance of vapor-liquid contactors

Schmit, Carolyn Elizabeth. January 2001 (has links) (PDF)
Thesis (Ph. D.)--University of Texas at Austin, 2001. / Vita. Includes bibliographical references. Available also from UMI Company.
3

Three-dimensional structure reconstruction from tomographic views.

January 1996 (has links)
by Ho, Chi-Kin. / Thesis (M.Phil.)--Chinese University of Hong Kong, 1996. / Includes bibliographical references (leaves 62-64). / Chapter 1 --- Introduction / Chapter 2 --- Previous Work --- p.2-1 / Chapter 2.1 --- Thresholding --- p.2-1 / Chapter 2.2 --- Edge Detection --- p.2-2 / Chapter 2.3 --- Region Growing --- p.2-2 / Chapter 2.4 --- Radial Contour Model --- p.2-3 / Chapter 2.5 --- Regularized Region Contrast --- p.2-3 / Chapter 2.6 --- Deformable Model --- p.2-4 / Chapter 3 --- The ODD-Balloons Model --- p.3-1 / Chapter 3.1 --- Design Rationale --- p.3-1 / Chapter 3.2 --- Overview --- p.3-5 / Chapter 3.3 --- 2-D Deformations --- p.3-8 / Chapter 3.4 --- Orthogonal Cut and Volume Transfer --- p.3-11 / Chapter 3.5 --- Smoothing Operation --- p.3-17 / Chapter 3.6 --- Properties --- p.3-20 / Chapter 3.6.1 --- Conformation to 3-D Shape --- p.3-20 / Chapter 3.6.2 --- Noise Sensitivity --- p.3-20 / Chapter 3.6.3 --- Convergence and Efficiency --- p.3-22 / Chapter 3.6.4 --- Easy-to-Use --- p.3-23 / Chapter 3.7 --- Summary --- p.3-24 / Chapter 4 --- Experiment Results --- p.4-1 / Chapter 4.1 --- Synthetic Data Experiments --- p.4-1 / Chapter 4.2 --- Real Data Experiment --- p.4-3 / Chapter 4.3 --- Discussions --- p.4-6 / Chapter 5 --- Conclusion and Future Work --- p.5-1 / Chapter 5.1 --- Conclusion --- p.5-1 / Chapter 5.2 --- Recommended Future Work --- p.5-2 / Appendix A Discrete Implementation of 2-D Deformation --- p.A-1 / Appendix B Choosing Elasticity and Rigidity Coefficients of 2-D Deformation --- p.B-1 / Bibliography --- p.BIB-1
4

Adequacy of consenting patients for computed tomography (CT) scans in a developing country: a survey of two academic hospitals in Johannesburg, South Africa

Shayingca, Thandaza Mitchel 27 March 2015 (has links)
A research report submitted to the Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, in partial fulfilment of the requirements for the degree of Master of Medicine in Diagnostic Radiology Johannesburg, 2014 / INTRODUCTION South Africa presents a complex scenario with regard to patients consenting for medical procedures, because of the differing profiles of the population and the health care workers who perform the consenting procedures. AIM To evaluate consenting practice for CT scanning, within the South African tertiary referral setting and to determine if there are any associations between patient demographic profile and the level of understanding with the adequacy of consent. METHOD A prospective survey regarding consenting practices for CT scanning was performed in a form of an interview questionnaire in patients presenting to Chris Hani Baragwanath Academic and Charlotte Maxeke Johannesburg Academic hospitals. Determination of any associations between patient age, racial group, language and education was made with the level of understanding and adequacy of consent. RESULTS The survey was conducted on 117 patients; 86 from Charlotte Maxeke Johannesburg Academic Hospital and 31 from Chris Hani Baragwanath Academic Hospital. We found no significant association between gender and age category (p=0.11), racial group (p=0.17), education (p=0.26), home language (p=0.21) or residential area type (p=0.70). vi There was a significant, weak, association between age category and education (p=0.043; Cramer’s V=0.29). There was a significant, moderate association between the understanding of the language of consent and the home language of the patients (p=0.0013; phi coefficient=0.43). There was also some association between education and age. Just over 50% of patients felt that they had been given enough information and had had an opportunity to ask questions and only 33% had been offered an alternative to the CT scan. There was a significant difference in the mean adequacy of consent score with regards to racial group (p<0.0001), home language (p=0.0073), residential area type (p<0.0001) and level of education (p<0.0001). CONCLUSION Language differences between patients and personnel performing the consent procedure proved to be a major barrier in offering adequate consenting for CT Scans.
5

Theoretical and experimental evaluation of spatial resolution in a variable resolution X-Ray computed tomography scanner

Melnyk, Roman, January 2007 (has links) (PDF)
Thesis (Ph.D.)--University of Tennessee Health Science Center, 2007. / Title from title page screen (viewed on July 18, 2008). Research advisor: Frank A. DiBianca, Ph.D. Document formatted into pages (xii, 193, p. : ill.). Vita. Abstract. Includes bibliographical references (p. 186-193).
6

Computerised microtomography : non-invasive imaging and analysis of biological samples, with special reference to monitoring development of osteoporosis in small animals /

Stenström, Mats, January 1900 (has links)
Diss. (sammanfattning) Linköping : Univ., 2001. / Härtill 5 uppsatser.
7

Computed tomography demonstration of the complications and associations of lymphobronchial tuberculosis in children

Lucas, Susanna 03 April 2012 (has links)
M.Med. (Radiology), Faculty of Health Sciences, University of the Witwatersrand, 2011 / Lymphobronchial tuberculosis (LBTB) is tuberculous lymphadenopathy involving the airways, which is particularly common in children. AIM: To describe the CT findings of LBTB in children, the parenchymal complications and associated abnormalities. METHOD: CT scans of 98 children with LBTB were retrospectively reviewed. Lymphadenopathy, bronchial narrowing, parenchymal complications and associations were documented. RESULTS: Infants comprised 51% of patients. The commonest lymphadenopathy was subcarinal (97% of patients). Bronchial compressions (259 in total) were present in all patients, of which 23% were severe / complete stenoses and 28% affected bronchus intermedius. Parenchymal complications were present in 94% of patients, including consolidation (88%), breakdown (42%), air trapping (38%), expansile pneumonia (28%), collapse (17%) and bronchiectasis (9%), all predominantly right-sided (63%). Associations included oval focal bodies, miliary nodules, pleural disease and intracavitory bodies. CONCLUSIONS: The most important CT finding of children with LBTB is visible airway compression as a result of lymphadenopathy. CT of children with LBTB showed that airway compressions were more severe in infants and most commonly involved bronchus intermedius. Numerous parenchymal complications were documented, all showing rightsided predominance. Several associations were identified.
8

The distribution and volume of visceral and subcutaneous adipose tissue, derived from CT examination.

January 1998 (has links)
by Poon Mei Yu. / Thesis submitted in: Dec. 1997. / Thesis (M.Phil.)--Chinese University of Hong Kong, 1998. / Includes bibliographical references (leaves 127-132). / Abstract also in Chinese. / Declaration --- p.i / Acknowledgement --- p.ii / Table of Contents --- p.iii / Abbreviations --- p.xi / List of Figures --- p.xiv / List of Tables --- p.xvii / Abstract --- p.xxi / Introduction --- p.1 / Chapter Chapter 1: --- Obesity & related abnormalities --- p.2 / Chapter Chapter 2: --- Measurement of body fat --- p.11 / Objective --- p.18 / Chapter Chapter 3: --- Purpose of study --- p.19 / Method --- p.24 / Chapter Chapter 4: --- Technical considerations on CT technique --- p.25 / Chapter Chapter 5: --- Data Collection --- p.32 / Chapter Chapter 6: --- Data Analysis --- p.44 / Results --- p.49 / Chapter Chapter 7: --- Amount of adipose tissue --- p.50 / Chapter Chapter 8: --- "Adipose tissue distribution, VSR & VTR" --- p.81 / Discussion --- p.105 / Chapter Chapter 9: --- Discussion --- p.106 / Conclusions --- p.122 / Chapter Chapter 10: --- Conclusions --- p.123 / References --- p.127 / Appendix I --- p.133 / Appendix II --- p.136 / Appendix III --- p.139 / DECLARATION --- p.i / ACKNOWLEDGEMENT --- p.ii / TABLE OF CONTENTS --- p.iii / Brief Contents --- p.iii / Detailed Contents --- p.v / ABBREVIATIONS --- p.xi / LIST OF FIGURES --- p.xiv / LIST OF TABLES --- p.xvii / ABSTRACT --- p.xxi / INTRODUCTION --- p.1 / Chapter Chapter 1: --- OBESITY & RELATED ABNORMALITIES --- p.2 / Chapter 1.1 --- Adipose Tissue --- p.2 / Chapter 1.2 --- Classification of Adiposity --- p.3 / Chapter 1.3 --- Obesity --- p.5 / Chapter Chapter 2: --- MEASUREMENT OF BODY FAT --- p.11 / Chapter 2.1 --- Methods of Measuring Body Fat --- p.11 / Chapter 2.1.1 --- Non-imaging Methods --- p.12 / Chapter 2.1.2 --- Imaging Methods --- p.13 / Chapter 2.1.2.1 --- Plain radiograph --- p.13 / Chapter 2.1.2.2 --- Ultrasound --- p.13 / Chapter 2.1.2.3 --- Computed tomography --- p.14 / Chapter 2.1.2.4 --- Magnetic resonance imaging --- p.16 / OBJECTIVE --- p.18 / Chapter Chapter 3: --- PURPOSE OF STUDY --- p.19 / Chapter 3.1 --- Objectives --- p.19 / Chapter 3.2 --- Explanation --- p.20 / Chapter 3.2.1 --- Best level of AT area measurement --- p.21 / Chapter 3.2.2 --- Linear AT dimension --- p.22 / Chapter 3.2.3 --- Sex and age differences --- p.22 / Chapter 3.2.4 --- Difference in attenuation interval of fat --- p.23 / METHOD --- p.24 / Chapter Chapter 4: --- TECHNICAL CONSIDERATIONS ON CT TECHNIQUE --- p.25 / Chapter 4.1 --- Defining Anatomy --- p.25 / Chapter 4.1.1 --- Abdominal visceral cavity --- p.26 / Chapter 4.1.1.1 --- Diaphragm --- p.26 / Chapter 4.1.1.2 --- Pelvis --- p.26 / Chapter 4.1.1.3 --- Boundary at mid-potion --- p.27 / Chapter 4.1.2 --- Intra- and retro- peritoneal compartments --- p.28 / Chapter 4.2 --- Attenuation interval of fat --- p.29 / Chapter 4.2.1 --- Distinctive pixel value vs. attenuation interval --- p.30 / Chapter 4.2.2 --- Choice of interval --- p.30 / Chapter Chapter 5: --- DATA COLLECTION --- p.32 / Chapter 5.1 --- Subjects --- p.32 / Chapter 5.2 --- Acquisition --- p.33 / Chapter 5.3 --- Measurement --- p.34 / Chapter 5.3.1 --- AT area measurement --- p.35 / Chapter 5.3.2 --- Linear AT measurement --- p.38 / Chapter 5.3.2.1 --- Subcutaneous AT thickness --- p.38 / Chapter 5.3.2.2 --- Visceral AT thickness --- p.39 / Chapter Chapter 6: --- DATA ANALYSIS --- p.44 / Chapter 6.1 --- Tools --- p.44 / Chapter 6.2 --- Mathematical Assumptions --- p.45 / RESULTS --- p.49 / Chapter Chapter 7: --- AMOUNT OF ADIPOSE TISSUE --- p.50 / Chapter 7.1 --- AT Volumes --- p.50 / Chapter 7.1.1 --- In male and female subgroups --- p.50 / Chapter 7.1.2 --- VAT and SAT increase with TAT --- p.52 / Chapter 7.1.3 --- A VAT volume vs. VAT volume --- p.54 / Chapter 7.2 --- AT Areas at Various Anatomical Levels --- p.55 / Chapter 7.2.1 --- In male and female subgroups --- p.56 / Chapter 7.2.2 --- Correlation between AT volumes and areas --- p.62 / Chapter 7.2.3 --- Prediction of abdominal AT volumes from AT areas --- p.63 / Chapter 7.3 --- Linear AT Dimensions --- p.66 / Chapter 7.3.1 --- Linear SAT dimensions correlated to AT volumes --- p.66 / Chapter 7.3.2 --- Linear VAT dimensions correlated to AT volumes --- p.68 / Chapter 7.3.3 --- Prediction of abdominal SAT volume --- p.70 / Chapter 7.3.4 --- Prediction of abdominal A VAT volume --- p.71 / Chapter 7.3.5 --- Prediction of abdominal TAT volume --- p.72 / Chapter 7.4 --- "AT Measurements, Sex and Age" --- p.73 / Chapter 7.4.1 --- In whole study population --- p.73 / Chapter 7.4.2 --- In male and female subgroups --- p.75 / Chapter 7.5 --- Difference in Attenuation Interval --- p.79 / Chapter Chapter 8: --- DISTRIBUTION OF ADIPOSE TISSUE: VSR & VTR --- p.81 / Chapter 8.1 --- VSR --- p.81 / Chapter 8.1.1 --- Correlation --- p.82 / Chapter 8.1.2 --- Prediction --- p.83 / Chapter 8.1.3 --- Effect of attenuation interval --- p.84 / Chapter 8.1.3.1 --- On VSR value --- p.84 / Chapter 8.1.3.2 --- On correlation and prediction results --- p.86 / Chapter 8.2 --- VTR --- p.88 / Chapter 8.2.1 --- Correlation --- p.88 / Chapter 8.2.2 --- Prediction --- p.89 / Chapter 8.2.3 --- Effect of attenuation interval --- p.91 / Chapter 8.2.3.1 --- On VTR value --- p.91 / Chapter 8.2.3.2 --- On correlation and prediction results --- p.93 / Chapter 8.3 --- VSR vs. VTR --- p.95 / Chapter 8.4 --- "VSR, VTR, Sex and Age" --- p.96 / Chapter 8.4.1 --- Correlation --- p.99 / Chapter 8.4.2 --- Prediction --- p.100 / Chapter 8.4.3 --- VSR and VTR increase with age --- p.101 / DISCUSSION --- p.105 / Chapter Chapter 9: --- DISCUSSION --- p.106 / Chapter 9.1 --- Absolute AT Content (Amount) --- p.106 / Chapter 9.1.1 --- AT areas of various anatomical levels --- p.106 / Chapter 9.1.1.1 --- Correlated to AT volume --- p.107 / Chapter 9.1.1.2 --- Prediction of abdominal A T volume: best level --- p.107 / Chapter 9.1.2 --- Linear AT dimensions --- p.109 / Chapter 9.1.2.1 --- Correlated to AT volume --- p.109 / Chapter 9.1.2.2 --- Prediction of abdominal AT volume --- p.111 / Chapter 9.2 --- AT Distribution Indices: VSR and VTR --- p.112 / Chapter 9.2.1 --- The best level --- p.114 / Chapter 9.3 --- Sex and Age Difference --- p.114 / Chapter 9.3.1 --- absolute AT content --- p.114 / Chapter 9.3.2 --- VSR and VTR --- p.116 / Chapter 9.4 --- Difference in Attenuation Interval --- p.118 / Chapter 9.4.1 --- Absolute AT content --- p.118 / Chapter 9.4.2 --- VSR and VTR --- p.119 / Chapter 9.5 --- Limitations --- p.120 / Chapter 9.5.1 --- Study population --- p.120 / Chapter 9.5.2 --- Differentiation of compartments --- p.121 / CONCLUSIONS --- p.122 / Chapter Chapter 10: --- CONCLUSIONS --- p.123 / Chapter 10.1 --- Absolute AT Content in Abdomen --- p.123 / Chapter 10.2 --- Abdominal AT Distribution --- p.125 / Chapter 10.3 --- Effect of Attenuation Interval --- p.126 / REFERENCES --- p.127 / APPENDIX I: Comparison of study populations & scanning techniques --- p.133 / APPENDIX II: Comparison of definitions of attenuation interval of fat and anatomical compartments --- p.136 / APPENDIX III: Statistical summary of the adipose tissue measurements in this study --- p.139
9

Development of a thermal neutron imaging facility for real time neutron radiography and computed tomography /

Jo, Young Gyun, January 1998 (has links)
Thesis (Ph. D.)--University of Texas at Austin, 1998. / Vita. Includes bibliographical references (leaves 209-211). Available also in a digital version from Dissertation Abstracts.
10

Rigid, multi-rigid, and non-rigid image registration of skeletal structures /

Hu, Yangqiu. January 2005 (has links)
Thesis (Ph. D.)--University of Washington, 2005. / Vita. Includes bibliographical references (leaves 101-107).

Page generated in 0.0546 seconds