• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • Tagged with
  • 23
  • 23
  • 14
  • 11
  • 7
  • 7
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Sistema multicanal de geração e recepção de ondas ultra-sonicas para transdutor matricial linear / Multichannel system for generation and detection of ultrasonic waves with a linear array transducer

Zanella, Fabio Pieroni 19 July 2006 (has links)
Orientador: Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-11T02:41:16Z (GMT). No. of bitstreams: 1 Zanella_FabioPieroni_M.pdf: 8365446 bytes, checksum: c1fa57572fdaf7e48b08a6a5fb58a524 (MD5) Previous issue date: 2006 / Resumo: O ultra-som na medicina tem passado por enorme evolução nas últimas décadas e ocupado posição de destaque cada vez maior como ferramenta para terapia e diagnóstico. Isso é devido principalmente ao fato de que os equipamentos de diagnóstico por ultra-som são de relativo baixo custo, o ultra-som é uma radiação não-ionizante e permite realização de exame por método não-invasivo e as imagens são geradas e visualizadas em tempo real. Na geração de imagens deste tipo, é comum a utilização de transdutores matriciais. Entretanto, o Brasil apresenta defasagem tecnológica com respeito à construção destes transdutores e à eletrônica envolvida em sua operação. O objetivo deste trabalho consistiu no desenvolvimento de circuitos eletrônicos com 12 canais de geração e de recepção de ondas ultra-sônicas para operação com transdutor matricial linear. O sistema é capaz de excitar transdutores piezoelétricos e receber ecos ultra-sônicos na faixa de 0,5 a 30 MHz e tem seus circuitos de recepção protegidos contra a alta tensão dos pulsos gerados para a excitação do transdutor. Os disparos dos elementos do transdutor e o tempo de corte dos sinais nos circuitos de recepção, para evitar receber sinais indesejáveis referentes ao período inicial de oscilação do transdutor, são controlados via circuito com microcontrolador PIC 16F877 que, juntamente com o programa de controle, foram desenvolvidos para conectar o sistema a um microcomputador. Os 12 canais foram caracterizados eletricamente e verificou-se seu funcionamento utilizando um transdutor piezoelétrico linear de 12 elementos com 1 MHz de freqüência central, especialmente desenvolvido para este trabalho. Os resultados mostraram que o sistema funciona adequadamente, gerando imagem de um phantom construído em nosso laboratório / Abstract: Ultrasound in medicine has gone through great evolution in the last few decades and has occupied important position as a tool for therapy and diagnosis. This is due to the ultrasound equipment be of relatively low-cost, ultrasound is a non-ionizing radiation, is a non-invasive imaging method, and the images are created and seen in real time. It is common the use of transducer arrays in order to generate this kind of image. There is a lack of know how in Brazil relative to the construction of these transducers and the involved electronics in their operation. The objective of this work was the development of a multi-purpose 12 channel pulser/receiver electronic circuitry to operate with linear transducer arrays. The system is able to fire ultrasound piezoelectric transducers and to receive ultrasound echo signals in the range 0.5-30 MHz. The system has reception circuits with protection against high voltage pulses. The firing of transducer elements and cutting time of the reception circuits, to avoid unwanted signals of natural initial transducer oscillations, can be controlled via PIC 16F877 hardware and software designed to connect the system to a microcomputer. The electrical characteristics of the 12 channel pulser/receiver and its use in firing a specially constructed 1 MHz 12 element PZT transducer array has been carried out and the images of a specially constructed phantom showed that it can be used in laboratory conditions / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
22

Métodos para o monitoramento da integridade de estruturas baseados em ondas de Lamb com arranjos multissensores / Methods for structural health monitoring based on Lamb waves with multisensors arrangements

Souza, Pablo Rodrigo de, 1978- 12 June 2013 (has links)
Orientador: Eurípedes Guilherme de Oliveira Nóbrega / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-23T01:49:32Z (GMT). No. of bitstreams: 1 Souza_PabloRodrigode_D.pdf: 10455045 bytes, checksum: b8461069008fc0a12ec07525f9bd8d2e (MD5) Previous issue date: 2013 / Resumo: O resumo poderá ser visualizado no texto completo da tese digital / Abstract: The abstract is available with the full electronic document / Doutorado / Mecanica dos Sólidos e Projeto Mecanico / Doutor em Engenharia Mecânica
23

Projeto, construção e caracterização de um amortecedor ativo controlado por atuador piezoelétrico / Design, construction and characterization controlled by Piezoelectric Actuato

Teixeira, Rafael Luís 22 February 2007 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / This thesis presents the design methodology, the construction of a prototype and the experimental validation of an active vibration damper witch is controlled by a piezoelectric actuator. The proposed device has two flexible metallic bellows connected to a rigid reservoir filled with a viscous fluid. When one of the bellows is connected to a vibrating structure a periodic flow passes through a variable internal orifice and the damping effect is produced. The size of the orifice is adjusted by a piezoelectric control system that positions the conical core into a conical cavity. The damper device finite element computational model was developed considering that the valve body is rigid and that the fluid - structure iteration occurs between the fluid and the flexible bellows. This model is discretized using a lagrangean-eulrian formulation. The actuator has a closed flexible metallic structure that amplifies the displacement produced by an internally mounted stack of piezoelectric ceramic layers, and it is also modeled by the finite element method. The damper prototype was built and experimental tests using impulsive and harmonic excitations were conducted to determine its dynamic behavior and also to validate the developed computational models. The simulation and experimental results are compared by curves that relate the damping coefficient with the size of the orifice. Reduced dynamical models are proposed to represent the behavior of the damper device with fixed and variable orifice sizes. A local classic PID controller for the piezoelectric actuator was design to assure that the valve core assume the correct position, providing the commanded damping coefficient. The damper device was applied to a vibration system that represents the model of a quarter-car vehicle. One on-off controller and another fuzzy controller were design to control the vibrations of the vehicle equipped with the proposed active damper. Experimental tests shown that the damping coefficient values, commanded by the global controller, were achieved in time intervals lesser than 10 milliseconds. These results demonstrate the very good performance of the proposed damper device. / Esta tese apresenta o desenvolvimento de uma metodologia de projeto, a construção de um protótipo e a validação experimental de um amortecedor ativo de vibrações controlado por um atuador piezelétrico. O dispositivo proposto contém um circuito hidráulico constituído por dois foles metálicos flexíveis conectados a um reservatório rígido cheio com um fluido viscoso. Quando um dos foles é conectado a uma estrutura vibratória um fluxo de fluido é forçado através de um orifício variável, produzindo o efeito de amortecimento. O tamanho do orifício é ajustado por um sistema piezelétrico de controle que posiciona um obturador cônico numa cavidade cônica. O amortecedor é modelado pela técnica dos elementos finitos considerando que o corpo da válvula rígido e que existe interação entre o fluido interno e a estrutura flexível dos foles. Este modelo é discretizado utilizando uma formulação Lagrangeana Euleriana. O atuador, composto por uma estrutura metálica flexível que amplifica o deslocamento produzido por uma pilha de cerâmicas piezelétricas, também é modelado pela técnica dos elementos finitos. Foi construído um protótipo do amortecedor e realizados ensaios experimentais com excitações impulsivas e harmônicas, para determinar o comportamento dinâmico e para validar os modelos computacionais desenvolvidos. A relação entre o tamanho do orifício e a correspondente força de amortecimento produzida é obtida tanto a partir de simulações feitas com o modelo computacional, como através de ensaios com o protótipo, para valores do tamanho do orifício fixos e variáveis. Propõe-se o uso de modelos dinâmicos reduzidos para representar a dinâmica do amortecedor. Para garantir que o atuador piezelétrico posicione corretamente o obturador da válvula, foi incorporado ao amortecedor um controlador local clássico tipo PID. O amortecedor ativo foi aplicado a um sistema vibratório que representa o modelo de um quarto de um automóvel. Desenvolveu-se projeto de um controlador liga - desliga e de um controlador fuzzy para controlar a vibração do veículo equipado com o amortecedor ativo. Testes experimentais mostraram que as alterações no valor do coeficiente de amortecimento da suspensão, comandadas pelo controlador global, foram realizadas em tempos inferiores a 10 milisegundos, indicando excelente desempenho do amortecedor proposto. / Doutor em Engenharia Mecânica

Page generated in 0.0783 seconds