• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 86
  • 2
  • Tagged with
  • 88
  • 88
  • 51
  • 39
  • 19
  • 18
  • 14
  • 12
  • 12
  • 12
  • 11
  • 11
  • 10
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Estudo da hidrodinamica e transferencia de calor do ovo integral liquido atraves de placas com tres formatos chevron / Study of hydrodynamics and heat transference from liquid whole egg through plate with three formats chevron

Bernardi, Marina 20 February 2008 (has links)
Orientadores: Vivaldo Silveira Junior, Javier Telis Romero / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-09T22:31:56Z (GMT). No. of bitstreams: 1 Bernardi_Marina_M.pdf: 337845 bytes, checksum: b22d2f1ecde63498948bfd0748a26993 (MD5) Previous issue date: 2008 / Resumo: Neste trabalho são apresentadas a hidrodinâmica e a transferência de calor no escoamento de ovo líquido integral através de dutos com paredes corrugadas, simulando trocadores de calor a placas. A condição de contorno admitida foi a de temperatura da parede constante durante o aquecimento do fluido. A reologia do ovo integral foi determinada experimentalmente em uma ampla faixa de temperaturas (289 ¿ 335K). O ovo apresentou comportamento reológico dependente do tempo, o qual foi explorado neste trabalho. Para os estudos da perda de carga e transferência de calor objetivando o dimensionamento correto de tubulações e equipamentos destinados ao transporte e processamento de fluidos tixotrópicos os parâmetros reológicos independentes do tempo foram empregados. O modelo de Ostwald-De Waelle foi ajustado às curvas reológicas experimentais desconsiderando a dependência do tempo. Foram realizadas medidas experimentais de perda de carga para a determinação do fator de atrito em função de um número de Reynolds generalizado, cujos resultados foram empregados para determinação dos parâmetros geométricos x e u para o regime laminar e dos parâmetros P1 e P2 para o regime turbulento. Esses parâmetros geométricos foram utilizados para correlacionar os coeficientes de transferência de calor convectivos experimentais com as propriedades físicas do fluido, resultando em equações formato clássico, Nusselt=Nu(Reg,Prg) / Abstract: At this work are showed the heat transference and hydrodynamics of liquid egg flow between ducts with corrugated walls, simulating plate heat exchangers. The contour conditions admitted was the constant temperature in the walls during the fluid heating. The whole egg rheology was experimentally determinated in a extend temperature range (289 ¿ 335K). The egg rheology behavior was time dependent, which was explored at the present work. However, to study the loss of load and heat transference this time dependence behavior was not considerated, because, according to Skelland, the correct sizing of equipments and tubings used to tixotropic fluid transport and processing must be done using time independent rheologic parameters. The Ostwald-De Waelle model was adjusted at the experimental rheologycal curves disrespecting the time dependence. It was realized experimental determinations of loss of load to determination of Fanning factor in function of Reynolds generalized number, and the results was used to determination of x and u geometrics parameters to laminar flow and P1 and P2 to turbulent flow. These geometrics parameters were used to correlated the experimental heat transference coefficient with the fluid physic properties resulting in equations on the classic format, Nusselt=Nu(Reg,Prg) / Mestrado / Mestre em Engenharia de Alimentos
82

Modelagem computacional do desempenho térmico de trocadores de calor de fluxo cruzado e casco e tubos / Numerical methodologies for thermal performance of crossflow and shell-and-tube heat exchangers

Felipe Costa Magazoni 18 November 2016 (has links)
O presente trabalho descreve e introduz uma metodologia numérica de simulação térmica de trocadores de calor de fluxo cruzado e de casco e tubo. A metodologia computacional é utilizada para simular doze configurações de arranjos de escoamento de trocadores de calor de fluxo cruzado com número de passes e tubos por passe arbitrários, assim como diversas condições de mistura de ambos os fluidos. O procedimento computacional é desenvolvido, baseado em diversos trabalhos da literatura, para calcular a efetividade de temperatura e o fator de correção da diferença média logarítmica de temperatura para trocadores de calor de fluxo cruzado em escoamentos contracorrente e paralelo. Novos dados da efetividade de temperatura e do fator de correção para configurações complexas de trocadores de calor são apresentados em diversas tabelas e figuras. As condições de mistura do fluido interno depois de cada passe são analisadas e caracterizadas por três configurações: misturado, não misturado com uma ordem idêntica das fileiras e não misturado com uma ordem inversa das fileiras. A influência da mistura do fluido externo entre os tubos do trocador de calor também é analisada. A metodologia computacional também é utilizada para trocadores de calor de casco e tubo tipo TEMA E com um passe de ambos os fluidos (fluidos do casco e dos tubos) em escoamentos contracorrente e paralelo de acordo com as entradas do trocador de calor. O algoritmo é baseado em diversas hipóteses e considerações de modelagem adotadas em diversos trabalhos de trocadores de calor de fluxo cruzado e de casco e tubo. Cada seção entre as chicanas é idealizada como um trocador de calor não misturado - não misturado. Além disso, este estudo fornece um sumário de correlações matemáticas exatas e aproximadas para algumas configurações de trocadores de calor de fluxo cruzado e de casco e tubo, que são muito apropriadas para análises computacionais e que facilitam o cálculo de efetividade de temperatura e do fator de correção. Os resultados encontrados são comparados com o algoritmo HETE e com soluções e relações matemáticas disponíveis em outras literaturas e mostram a capacidade dos algoritmos desenvolvidos. / The present thesis describes and introduces the numerical simulation methodologies for thermal modeling of crossflow and shell-and-tube heat exchangers. The computational methodology is used for simulating twelve general flow arrangement configurations of crossflow heat exchangers with arbitrary number of passes and tubes per pass, as well as, several mixture conditions of both fluids. The computational procedures are developed, based on some works from literature, to calculate the temperature effectiveness and the mean logarithm temperature difference (MLTD) correction factor for crossflow and parallel and counter-crossflow heat exchangers. New temperature effectiveness and correction factor data for the treated complex flow arrangements configurations are provided and showed in various tables and plots. Tube fluid mixing conditions after each pass, characterized by three types of configuration: tube fluid mixed; tube fluid unmixed keeping identical order of the rows; and tube fluid unmixed with inverted order of the rows, are analyzed. The influence of external fluid mixing between tube rows along the heat exchanger configurations is also addressed. The computational methodology is also addressed to TEMA E shell-and-tube heat exchangers type with one-pass of both fluids (in-tube and shell side) flowing in counterflow and parallel regarding the heat exchangers inlets. The algorithm is based on various assumptions and modelling considerations adopted in several works of crossflow and shell-and-tube heat exchangers. Each section between two baffles is idealized as an unmixed-unmixed crossflow heat exchanger. In addition, this study provides a summary of exact and approximate correlations for some configurations of crossflow and shell-and-tube heat exchangers, that are very appropriate for computerized analysis and that facilitate the computation of both parameters, the temperature effectiveness and the mean logarithmic temperature difference correction factor. The results found are compared to algorithm HETE and with available relations and solutions of other works and show the capability of the developed algorithm.
83

Optimization of vortex generators positions and angles in fin-tube compact heat exchanger at low Reynolds number. / Otimização das posições e ângulos dos geradores de vórtices em trocadores de calor compactos para baixo número de Reynolds.

Leandro Oliveira Salviano 25 April 2014 (has links)
In the last few decades, augmentation of heat transfer has emerged as an important research topic. Although many promising heat transfer enhancement techniques have been proposed, such as the use of longitudinal vortex generators, few researches deal with thermal optimization. In the present work, it was conducted an optimization of delta winglet vortex generators position and angles in a fin-tube compact heat exchanger with two rows of tubes in staggered tube arrangement. Two approaches were evaluated: Response Surface Methodology (Neural Networking) and Direct Optimization. Finite-Volume based commercial software (Fluent) was used to analyze heat transfer, flow structure and pressure loss in the presence of longitudinal vortex generators (LVG). The delta winglet aspect ratio was 2 and the Reynolds numbers, based on fin pitch, were 250 and 1400. Four vortex generator parameters which impact heat exchanger performance were analyzed: LVG position in direction x-y, attack angle (θ) and roll angle (ᵩ). The present work is the first to study the influence of LVG roll angle on heat transfer enhancement. In total, eight independent LVG parameters were considered: (x₁y₁θ₁ᵩ₁) for the first tube and (x₂y₂θ₂ᵩ₂) for the second tube. Factor Analysis method (software ModeFrontier) was used to study of the influence of these LVG parameters in heat exchanger performance. The effect of each LVG parameter on heat transfer and pressure loss, expressed in terms of Colburn factor (j) and Friction factor (f), respectively, were evaluated. The optimized LVG configurations led to heat transfer enhancement rates that are much higher than reported in the literature. Direct Optimization reported better results than Response Surface Methodology for all objective functions. Important interactions were found between VG1 and VG2, which influenced the results of Colburn (j) and Friction (f) factors for each Reynolds number. Particularly, it was found that the asymmetry of the LVG, in which the VG2 parameters strongly depend on the VG1 parameters, plays a key role to enhance heat transfer. Moreover, for each Reynolds number and each objective function, there is an optimal LVG arrangement. If the objective is to mitigate pressure drop, VG1 may be suppressed because its main goal is increasing the heat transfer downstream. On the other hand, VG2 was relevant for both increase the heat transfer and decrease the pressure drop. Roll angle had a strong influence on Friction factor (f), especially for VG1 and low Reynolds number. / Por muitos anos, a intensificação da transferência de calor tem despontado como um importante tópico de pesquisa. Embora existam muitas técnicas eficazes de intensificação da transferência de calor, como o uso de geradores de vórtices, poucos trabalhos de pesquisa lidam com a otimização. Neste trabalho, foi realizada a otimização das posições e ângulos dos geradores de vórtice longitudinal (LVG) tipo meia asa delta, considerando um trocador de calor tubo-aleta compacto com duas linhas de tubos desalinhados. Duas abordagens foram empregadas: Método da Superfície de Resposta (Neural Networking) e Otimização Direta. Um software comercial (Fluent), baseado na metodologia de volumes finitos, foi empregado na análise numérica da transferência de calor, estruturas vorticais e perda de pressão no escoamento, na presença de LVG. A razão de aspecto dos geradores de vórtice foi 2 e o número de Reynolds, baseado na distância entre as aletas, foram de 250 e 1400. Foram analisados quatro parâmetros dos LVG, os quais impactam na performance do trocador de calor: a posição do LVG na direção x-y, o ângulo de ataque (θ) e o ângulo de rolamento (ᵩ). O ângulo de rolamento foi primeiramente estudado neste trabalho. No total, oito parâmetros independentes do LVG foram considerados: (x₁y₁θ₁ᵩ₁) para o primeiro tubo e (x₂y₂θ₂ᵩ₂) para o segundo tubo. O método da Análise Fatorial (software ModeFrontier) foi aplicado no estudo da influência destes parâmetros dos LVG na performance do trocador de calor. Também foi avaliado o efeito de cada um destes parâmetros na transferência de calor e perda de pressão do escoamento, expressos em termos do fator de Colburn (j) e do fator de Atrito (f), respectivamente. As configurações otimizadas dos LVG, conduziram à taxas de transferência de calor maiores do que aquelas reportadas pela literatura. A Otimização Direta mostrou resultados melhores do que através da metodologia de Superfície de Resposta para todas as funções objetivas avaliadas neste trabalho. Importantes interações foram identificadas entre VG1 e VG2, os quais influenciaram nos resultados dos fatores de Colburn (j) e Atrito (f) para cada número de Reynolds. Particularmente, foi identificado que a assimetria dos LVG desempenha um papel fundamental na intensificação da transferência de calor, onde os parâmetros de VG2 dependem fortemente dos parâmetros de VG1. Além disso, para cada número de Reynolds e para cada função objetivo, existe uma configuração ótima dos parâmetros do LVG. Se o objetivo é a redução da perda de pressão global, VG1 poderia ser suprimido da modelagem, pois a sua principal função é aumentar a transferência de calor ao longo da aleta. Por outro lado, VG2 foi relevante tanto para aumentar a transferência de calor quanto para diminuir a perda de pressão. O ângulo de rolamento teve grande influência sobre o resultado do fator de Atrito (f), especialmente para VG1 e para baixo número de Reynolds.
84

[pt] DESENVOLVIMENTO E VALIDAÇÃO EXPERIMENTAL EM USINA HIDRELÉTRICA DE ALTERNATIVAS DE CÁLCULO DA EFETIVIDADE DE TROCADORES DE CALOR / [en] DEVELOPMENT AND EXPERIMENTAL VALIDATION IN A HYDROELECTRIC PLANT OF ALTERNATIVES FOR CALCULATING THE EFFECTIVENESS OF HEAT EXCHANGERS

EDGARDO RAFAEL CASTRO PACHECO 23 February 2021 (has links)
[pt] Esta dissertação teve como objetivo desenvolver uma sistemática de monitoramento para avaliar, em tempo real, a efetividade térmica de trocadores de calor (água-ar) do sistema de arrefecimento de hidrogeradores. A motivação resultou da possibilidade de se estabelecer ganhos de efetividade pela racionalização do procedimento de limpeza. Como metodologia de desenvolvimento do trabalho, duas estratégias foram perseguidas: (i) proposição de alternativas de cálculo da efetividade sem a necessidade de medir a temperatura de saída do ar (fluido quente do trocador) em um complexo escoamento perturbado por sucessivos descolamentos da camada limite em torno de cada tubo do trocador e (ii) validação da alternativa de cálculo da efetividade com base em dados reais de monitoramento de um trocador de calor de hidrogerador, em operação contínua, mesmo durante a sua limpeza on-line, portanto sem requerer a parada técnica das turbinas. Dentre os resultados, duas alternativas de cálculo da efetividade do trocador foram desenvolvidas: (i) via solução numérica do sistema de equações que governam os mecanismos de transferência de calor e (ii) via uma versão adaptada do método Épsilon-NTU, que avalia a efetividade de um trocador de calor de seis passes modelando-o como um arranjo em série de seis trocadores de um único passe. As alternativas de cálculo da efetividade apresentam concordância de cerca de 1 por cento e com baixo nível de incerteza (0,012), podendo diferir em até 30 por cento quando confrontadas com o método usual fundamentado na medição da temperatura de saída do ar. Como conclusão, as alternativas propostas mostraram-se adequadas para calcular a efetividade do trocador de calor do sistema de arrefecimento dos hidrogeradores da usina Fontes Nova (Piraí/RJ), monitorado ao longo de um período de 11 meses e sem requerer a interrupção da geração. / [en] This dissertation aimed to develop a monitoring system to evaluate, in real time, the thermal effectiveness of heat exchangers (water-air) of the cooling system of hydrogenerators. The motivation resulted from the possibility of establishing gains in effectiveness by rationalizing the cleaning procedure. As a methodology for the development of the work, two strategies were pursued: (i) proposition of alternatives for calculating effectiveness without the need to measure the outlet temperature of the air (hot fluid of the exchanger) in a complex flow disturbed by successive detachments of the boundary layer around each tube of the exchanger and (ii) validation of the alternative of calculating the exchanger effectiveness based on real data acquired during the continuous operation of the hydrogenerator unit, including the online cleaning process of the exchanger without the technical stop of the turbines. Among the results, two alternatives for calculating the effectiveness of the exchanger were developed: (i) via a numerical solution of the system of equations that govern the heat transfer mechanisms involved and (ii) via an adapted version of the Epsilon-NTU method, which evaluates the effectiveness of a six-pass heat exchanger modeling it as a series arrangement of six single pass heat exchangers. The alternatives for calculating the exchanger effectiveness have an agreement of about 1 percent and with low level of uncertainty (0.012), which may differ by up to 30 percent when compared with the usual method based on the measurement of the outlet air temperature. In conclusion, the proposed alternatives proved to be adequate to calculate the effectiveness of the heat exchanger of the cooling system of the hydrogenerators at the Fontes Nova plant (Piraí / RJ), monitored over a period of 11 months and without requiring interruption of the generation.
85

[en] EXPERIMENTAL DETERMINATION OF TRANSPORTATIONS COEFFICIENTS FOR ICE SLURRY IN PLATE HEAT EXCHANGERS / [pt] DETERMINAÇÃO EXPERIMENTAL DOS COEFICIENTES DE TRANSPORTE DA PASTA DE GELO EM TROCADORES DE CALOR DE PLACAS

LUIS CARLOS CASTILLO MARTINEZ 25 August 2005 (has links)
[pt] A pasta de gelo é uma mistura de água e um aditivo, com finas partículas de gelo, apresentando uma alta densidade de energia térmica. O principal motivo de sua utilização deve-se à combinação do aproveitamento do calor latente na mudança de fase com capacidade de ser bombeado. O presente trabalho trata do estudo experimental sobre a transfe rência de calor e queda de pressão, com mudança de fase, utilizando uma mistura de propileno glicol - água com 13,8% de concentração em peso, num trocador de calor de placas com arranjo em U para 16 placas. Realizaram-se testes de troca de calor com escoamento em paralelo e contra-corrente, para duas condições de fração mássica de gelo e números de Reynolds para a pasta de gelo entre 150 e 425, com diferentes condições de carga térmica. Dos testes foram observados aumentos de até 25% no coeficiente global de troca calor, ao se incrementar a vazão e, conseqüentemente, o número de Reynolds da pasta de gelo. Com o aumento da fração de gelo melhora-se a capacidade de resfriamento, diminuindo o número de Nusselt da pasta de gelo. O coeficiente global de troca, porém, começa a diminuir. Na literatura esta relação ainda não está bem definida. Alguns autores relatam ganhos, perdas ou indiferença no coeficiente global. Resultados do coeficiente global e do número de Nusselt, nos modos paralelo e contra-corrente, não apresentaram grande diferença. A capacidade de resfriamento em contra-corrente foi maior, apresentando valores de efetividade cerca 10% acima dos resultados observados no modo paralelo. Os fatores de atrito encontrados variaram entre 0,030 a 0,085, o que concorda com os resultados apresentados por outros pesquisadores. Como era de se esperar, o fator de atrito diminui com o aumento da vazão mássica e de maneira inversa com o aumento da fração de gelo. / [en] Ice slurry is an aqueous solution from which ice crystals are formed. These crystals possess high energy density, in the form of latent heat. Furthermore, the fact of being a slurry makes it an excellent energy carrier, for it can be easily pumped. The present work presents an experimental procedure to assess the heat transfer and the pressure loss, with phase change, using a mixture of propyleneglycol and water, 13.8% weight, in a U-plate heat exchanger with 16 plates. Tests were carried out for both parallel and counter-flow configurations of the heat exchanger, for two different mass fractions of ice and with Reynolds numbers between 150 and 425 for the slurry. Different thermal loads were considered. The experiments showed increases of up to 25% in the overall heat transfer coeficiente when the slurry flow is increased, with consequent increase in the Reynolds number. By increasing the ice fraction the cooling capacity is improved, reducing the Nusselt number. In the literature, this relationship is not clearly defined, as some authors show gains in the heat exchange coefficient, losses, and some others did not observe any influence on this parameter. Regarding the heat Exchange configuration, i.e., parallel or counter-flow, neither the heat exchange coefficient, nor the Nusselt number suffered major influence. The effectiveness is up to 10% higher for the counter-flow configuration in comparison with the parallel configuration. The figures found for the friction coefficient, between 0,030 and 0,085, are in good agreement with the literature. As expected, the friction coefficient decreases when the mass flow is increased, and increases when the ice fraction is increased.
86

[pt] AVALIAÇÃO METROLÓGICA DE UM DISPOSITIVO SERVO-HIDRÁULICO PARA MITIGAÇÃO DE INCRUSTAÇÃO EM TROCADORES DE CALOR INDUSTRIAIS / [en] METROLOGICAL EVALUATION OF A SERVO-HYDRAULIC DEVICE TO MITIGATE FOULING IN INDUSTRIAL HEAT EXCHANGERS

JEFFERSON LUIZ RANGEL RIOS 23 February 2021 (has links)
[pt] Incrustações em trocadores de calor são inevitáveis e provocam a redução da sua efetividade térmica e aumento nos custos de bombeamento. Esta dissertação objetiva validar um dispositivo alternativo de limpeza de trocadores de calor, que automatiza o processo e não requer a interrupção do processo industrial que faz uso de trocadores. A motivação da pesquisa resultou do desafio imposto ao Programa de Metrologia da PUC-Rio para conceber uma solução inovadora para realizar a limpeza on-line de trocadores de calor de hidrogeradores, viabilizada com financiamento do setor elétrico e que motivou esta dissertação. A metodologia de desenvolvimento da pesquisa de mestrado perseguiu duas estratégias de otimização: (i) aprimorar a hidrodinâmica dos circuitos hidráulicos do dispositivo de limpeza concebido, visando reduzir custos de bombeamento e (ii) simular o número de ciclos mínimos de limpeza para assegurar que todos os tubos do trocador de calor sejam visitados por artefatos de limpeza. Dentre os resultados consolidados, destacam-se: (i) melhoria dos fluxos hidrodinâmicos nos distintos tramos hidráulicos do dispositivo servo-hidráulico de limpeza; (ii) confiabilidade metrológica do sistema de medição embarcada no equipamento e (iii) desenvolvimento de modelagem probabilística capaz de prever o número de ciclos de limpeza capaz de assegurar eficácia do procedimento de limpeza do trocador, o que contribui para o seu entendimento. Os ensaios de desempenho realizados em laboratório suportam a conclusão de que a pesquisa de mestrado foi capaz de validar e disponibilizar uma versão hidrodinamicamente mais eficiente e operacionalmente mais eficaz do dispositivo de limpeza originalmente concebido. / [en] Fouling in heat exchangers is inevitable and causes a reduction in their thermal effectiveness and an increase in pumping costs. This dissertation aims to validate an alternative heat exchanger cleaning device, which automates the process and does not require the interruption of the industrial process that uses exchangers. The motivation for the research resulted from the challenge imposed on the Metrology Program at PUC-Rio to devise an innovative solution to perform the online cleaning of hydrogenerator heat exchangers, made possible with financing from the electricity sector and which motivated this dissertation. The master s research development methodology pursued two optimization strategies: (i) improving the hydrodynamics of the hydraulic circuits of the designed cleaning device, aiming to reduce pumping costs and (ii) simulating the number of minimum cleaning cycles to ensure that all the tubes of the heat exchanger are visited by cleaning artefacts. Among the consolidated results, the following stand out: (i) improvement of hydrodynamic flows in the different hydraulic sections of the servo-hydraulic cleaning device; (ii) metrological reliability of the measurement system embarked in the equipment and (iii) development of probabilistic modeling capable of predicting the number of cleaning cycles capable of ensuring the efficiency of the exchanger cleaning procedure, which contributes to its understanding. The performance tests performed in the laboratory support the conclusion that the master s research was able to validate and make available a hydrodynamically more efficient and operationally more effective version of the cleaning device originally designed.
87

Estudo de integração energética de rede de trocador de calor e emissão de gases de efeito estufa em processos industriais

Liem, Rosana Maria 19 June 2013 (has links)
Made available in DSpace on 2016-06-02T19:56:51Z (GMT). No. of bitstreams: 1 5317.pdf: 4354756 bytes, checksum: c3428f42cdc8f5cda6298342a6938dab (MD5) Previous issue date: 2013-06-19 / In light of the scientific evidence for global warming, the United Nations established the Framework Convention on Climate Change and defined the Kyoto Protocol that provided opportunities for sustainable social and economic development. The Clean Development Mechanism (CDM) is one of the protocols applicable to developing countries such as Brazil. Opportunities for industries to reduce greenhouse gas (GHG) emissions can be led by thermal energy integration studies. In addition, sustainable processes can result in energy savings as well as help to mitigate GHG emissions. This work presents a study of heat exchanger network (HEN) synthesis in order to reduce energy consumption and GHG emissions, and the benefits are evaluated in terms of energy savings and carbon credits for CDM projects. It was proposed to two case studies using HEN data from literature, one concerns burning fossil fuels, and other one was evaluated the bagasse combustion. Both studies were applied the Aspen Energy Analyzer® software and its performance of the design of the HEN employed the Automatic Retrofit and Automatic Recommend Designs features were evaluated too. GHG emissions were mitigated; the first case confirmed that the carbon credits improve Capital Expenditure Index, returning 13% less in payback depending on fossil fuel price. The second case presents a maximum value of reduction of 26.2% burning bagasse, 7.7% GHG emissions, 30% increase power generation, together with 19,411 carbon credits per year. / Em virtude da constatação inequívoca do aquecimento global, foi estabelecida pela Organização das Nações Unidas (ONU) a Convenção-Quadro sobre Mudança do Clima. No seu âmbito, foi criado o Protocolo de Quioto, que define mecanismos que enquadram responsabilidades e obrigações, abrindo oportunidades de desenvolvimento social e econômico sustentável. Um dos mecanismos estabelecido é o Mecanismo de Desenvolvimento Limpo (MDL), o único aplicável a países em desenvolvimento como o Brasil. Assim, no âmbito industrial existem várias oportunidades de redução das emissões de gases de efeito estufa (GEE) aliados a trabalhos de integração energética. Além do comprometimento sustentável, é possível obter cenários economicamente viáveis devido à redução de energia associada à mitigação das emissões de GEE. O objetivo deste trabalho foi estudar a síntese de rede de trocadores de calor (RTC) na redução do consumo de utilidades e de emissões de GEE, além de contabilizar os benefícios gerados na economia de combustíveis e a obtenção de créditos de carbono ligados a projetos que promovem o desenvolvimento limpo. Foram realizados dois estudos de casos com os dados da RTC obtidos da literatura, um referente à queima de combustíveis fósseis e outro referente à combustão do bagaço. Em ambos os estudos foi utilizado o software Aspen Energy Analyzer®, tendo como opções as ferramentas Automatic Retrofit e Automatic Recommend Designs, sendo estas avaliadas quanto ao seu desempenho na otimização da RTC. Foram mitigadas as emissões dos GEE, sendo que o primeiro caso foi comprovado que os créditos de carbono promovem um retorno financeiro mais rápido de até 13% dependendo do combustível fóssil e no segundo foi obtida uma redução de até 26,2% da queima do bagaço, 7,7% das emissões de GEE, geração extra de energia elétrica de até 30% e crédito de carbono de até 19.411 t CO2 ao ano.
88

[en] CFD SIMULATION OF THE FLOW IN THE HYDRAULIC CIRCUITS OF AN ONLINE HEAT EXCHANGER CLEANING DEVICE / [pt] SIMULAÇÃO CFD DO ESCOAMENTO NOS CIRCUITOS HIDRÁULICOS DE UM DISPOSITIVO DE LIMPEZA ONLINE DE TROCADORES DE CALOR

SERGIO LUIS DE LA HOZ TRUYOLL 09 July 2024 (has links)
[pt] Trocadores de calor são equipamentos essenciais do sistema de resfriamento de equipamentos de processo, visando assegurar a sua eficácia e eficiência operacional. O objetivo do trabalho é a simulação computacional do escoamento do fluido de transporte dos artefatos de limpeza de uma alternativa tecnológica de trocadores de calor que dispensa a interrupção do processo industrial. A motivação resultou do potencial da ferramenta computacional CFD em gerar resultados numéricos de interesse, complementando a base de dados experimentais em locais críticos do escoamento difíceis de serem instrumentados. A simulação foi realizada pelo Fluent/Ansys 2023 R2, utilizando-se o modelo de turbulência κ-ômega SST (Transporte da tensão de cisalhamento), baseado na abordagem média de Reynolds (RANS - Reynolds-Averaged Navier-Stokes). Os resultados da simulação (campos de velocidade, pressão e estruturas da turbulência) orientaram ajustes e melhorias localizadas no projeto construtivo da alternativa tecnológica de limpeza online proposta, permitindo eliminar zonas de recirculação e uma redução de 62,2 por cento nas perdas de carga localizadas, que tão drasticamente impactam nos custos de bombeamento do fluido de transporte dos artefatos de limpeza. A pressão simulada reproduziu o resultado da medição com 2,5 por cento de concordância. Como conclusão, a ferramenta computacional provou ser estratégica para orientar a melhoria do projeto construtivo do dispositivo inovador de limpeza online. Se por um lado os dados experimentais provêm uma referência confiável fundamentada em medições rastreáveis a padrões de referência, por outro, a simulação numérica provê relevantes informações em todo o domínio do escoamento. / [en] Heat exchangers are essential equipment in the cooling system of various process equipment, aiming to ensure its effectiveness and operational efficiency. The objective of the work is the computational simulation of the fluid flow transporting cleaning artifacts from a technological alternative for heat exchangers that does not require interruption of the industrial process. The motivation resulted from the potential of the CFD computational tool to generate numerical results of interest, complementing the experimental database in critical flow locations that are difficult to instrument. The simulation was carried out by Fluent/Ansys 2023 R2, using the κ-omega SST (Shear Stress Transport) turbulence model based on the Reynolds average approach (RANS - Reynolds-Averaged Navier-Stokes). The simulation results (velocity, pressure fields, and turbulence structures) guided adjustments and localized improvements in the constructive design of the proposed online cleaning technological alternative, allowing the elimination of recirculation zones and a 62.2 percent reduction in localized pressure losses that so drastically impact the costs of pumping the fluid to transport cleaning artifacts. The simulated pressure reproduced the measurement results with 2.5 percent agreement. In conclusion, the computational tool proved to be strategic in guiding the improvement of the constructive design of the innovative online cleaning device. If, on the one hand, experimental data provides a reliable reference based on measurements traceable to reference standards, numerical simulation provides relevant information across the entire flow domain.

Page generated in 0.0774 seconds