• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 619
  • 6
  • 5
  • 5
  • 5
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 628
  • 175
  • 167
  • 134
  • 124
  • 122
  • 121
  • 87
  • 85
  • 83
  • 83
  • 66
  • 57
  • 50
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

Emissão de CO2 do solo associado à calagem em área de conversão de laranja para cana-de-açúcar

Silva, Eliton de Freitas [UNESP] 13 December 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-12-13Bitstream added on 2014-06-13T20:50:10Z : No. of bitstreams: 1 000747108.pdf: 1427981 bytes, checksum: 39687bf609957df2e9dace8180945d42 (MD5) / A emissão de CO2 do solo (FCO2) em áreas agrícolas é resultante da interação de diversos fatores, sendo alterada pela prática de manejos do solo e da cultura, além das condições edafoclimáticas locais. Neste estudo, objetivou-se quantificar a FCO2 em função da aplicação de calcário e posição de plantio (linha e entrelinha) da cultura de laranja em área de implantação da cultura da cana-de-açúcar no município de Frutal-MG. Os tratamentos avaliados foram: Linha/CC (linha de plantio com aplicação de calcário), Entrelinha/CC (entrelinha de plantio com aplicação de calcário), Linha/SC (linha de plantio sem aplicação de calcário) e Entrelinha/SC (entrelinha de plantio sem aplicação de calcário). FCO2, temperatura do solo (Ts) e umidade do solo (Us) foram avaliadas durante 12 dias. O maior valor médio da FCO2 ao longo do período de estudo foi observado no tratamento Linha/CC (9,63 μmol m-2 s-1) e o menor no tratamento Entrelinha/CC (5,92 μmol m-2 s-1) segundo teste de Tukey. A FCO2 foi negativamente correlacionada a Us na Linha/CC (r = -0,56; p < 0,05) e na Linha/SC (r = -0,66; p < 0,05). Entre a FCO2 e a Ts verificou-se correlação positiva e significativa na Linha/CC (r = 0,76; p < 0,001), na Linha/SC (r = 0,89; p < 0,001) e na Entrelinha/SC (r = 0,66; p < 0,05). Observou-se que a calagem e a posição (Linha e Entrelinha) influenciaram nas emissões de CO2 do solo / The soil CO2 emission (FCO2) in agricultural areas is resulting from the interaction of several factors, as amended by the practice of soil management practices and crop, in addition to the local edaphoclimatic conditions. In this study aimed to quantify FCO2 depending on liming and planting position (row and interrow) of the orange crop in areas of deployment of the culture of cane sugar in the city of Frutal-MG. The treatments evaluated were: Row/CC (row planting with lime application), Interrow/CC (interrows with application of lime), Row/SC (row planting without liming) and Interrow/SC (interrows without liming). FCO2, temperature (Ts) and water content of soil moisture (Ms) were evaluated over 12 days. The highest average value of FCO2 over the study period was observed in the treatment Row/CC (9.63 μmol m-2 s-1) and the lowest in Interrow/CC (5.92 μmol m-2 s-1) according to the Tukey test. The FCO2 was negatively correlated with Us in Row/CC (r = -0.56, p < 0.05) and in Row/SC (r = -0.66, p < 0.05). It was also observed a significant and positive correlation between FCO2 and Ts in Row/CC (r = 0.76, p < 0.001), Row/SC (r = 0.89, p < 0.001) and in Interrow/SC (r = 0.66, p < 0.05). It was observed that liming and position (Row and Interrow) influenced the soil CO2 emissions
262

Curva de retenção de água no solo estimado pelo método da câmara de Richards e psicrômetro

Davalo, Marcelo Jara [UNESP] 31 July 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-31Bitstream added on 2014-06-13T19:50:06Z : No. of bitstreams: 1 000725696.pdf: 1833888 bytes, checksum: 06054a4f250b9da8bfbc1a84910037e3 (MD5) / A curva de retenção de água no solo é um atributo físico que expressa à relação entre o potencial mátrico e o conteúdo de água no solo, é um importante indicador de qualidade física do solo. Diante disso, o objetivo desta pesquisa foi determinar a curva de retenção de água utilizando a câmara de Richards e o psicrômetro WP4-T. Foram coletadas em um Neossolo Quartzarênico (RQ), Latossolo Vermelho Distófico (LVd1), Latossolo Vermelho Distófico (LVd2) e Latossolo Vermelho Eutroférrico (LVef), nas camadas de 0 a 0,1; 0,1 a 0,2 e 0,2 a 0,3 m, 40 amostras de solos indeformadas e deformadas que foram utilizadas para determinação das curvas de retenção de água do solo com a câmara de Richards, utilizando as pressões de 0, -0,001, -0,003, -0,006, -0,01, -0,033, -0,06, -0,1 e -0,3 MPa e com o psicrômetro WP4-T. As curvas de retenção de água no solo estimada pela câmara de Richards foram ajustadas pela equação de van Genuchten, obtendo-se os coeficientes θs, θr, α, m e n. Também foram mensuradas as variáveis porosidade total, macroporosidade, microporosidade, densidade do solo, granulometria, matéria orgânica, óxidos de ferro e de alumínio no solo. Essas variáveis e o conteúdo de água no solo estimada pela câmara de Richards foram submetidos às análises de correlações de Pearson. Verificou-se na região mais úmida da curva elevada dispersão dos pontos de pressão versus umidade obtidos com o psicrômetro WP4-T. As variáveis estruturais do solo apresentaram alta correlação com o maior conteúdo de água, porem com o aumento da sucção da água os atributos granulométricos juntamente com a matéria orgânica e os óxidos de ferro e alumínio apresentaram maior grau de relação com o conteúdo de água no solo. O método mais indicado para determinar a curva de retenção de água é a câmara de Richards e o psicrômetro WP4-T pode ser utilizado com precisão para determinar o conteúdo... / The retention curve of soil water is a physical attribute that expresses the relationship between the matric potential and water content in the soil is an important indicator of soil physical quality. Thus, the objective of this research was to determine the water retention curve using the camera Richards and psychrometer WP4-T. Were collected in a Quartzipsamments and oxisols, in layers from 0 to 0.1, 0.1 to 0.2 and 0, 2 to 0.3 m, 40 soil samples and undisturbed that were used to determine the retention curves of soil water with the camera Richards, using pressures of 0, -0.001, -0.003, -0.006, -0 , 01, -0.033, -0.06, -0.1 and -0.3 MPa and the psychrometer WP4-T. The retention curves of soil water estimated by camera Richards were adjusted by the van Genuchten equation, obtaining the coefficients θs, θr, α, n me. Variables were also measured total porosity, macroporosity, microporosity, bulk density, soil texture, organic matter, oxides of iron and aluminum in the soil. These variables and the water content in soil estimated by camera Richards were analyzed for Pearson correlations. It was found in the more humid high dispersion curve of the pressure points versus moisture psychrometer obtained with the WP4-T. Soil structural variables strongly correlated with higher water content but with the increase of the water suction texture attributes together with the organic matter and the oxides of iron and aluminum showed a higher degree of relation to the water content in soil. The most appropriate method to determine the water retention curve is camera Richards psychrometer and WP4-T can be used to accurately determine the water content at low potentials matrix
263

Otimização da tecnologia de assistência de ar em pulverizador de barras através da umidificação do fluxo de ar

Stanislavski, Wilson Marcos [UNESP] 29 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-08-29Bitstream added on 2014-06-13T20:12:49Z : No. of bitstreams: 1 stanislavski_wm_me_botfca.pdf: 539468 bytes, checksum: 9eeb49e3eba11e828c08973394be034e (MD5) / Universidade Estadual Paulista (UNESP) / A aplicação terrestre com assistência de ar é bastante difundida e tem sido incentivada devido ao potencial de maior eficiência quando comparada a aplicação terrestre convencional. Pulverizador com barra assistida a ar são amplamente utilizados em culturas de grandes extensões e em algumas situações de difícil penetração das gotas no dossel de culturas como soja e algodão. Entretanto, devido às grandes variações climáticas que ocorrem durante o período de aplicação, o rendimento operacional é prejudicado pelas paradas devido à baixa umidade relativa do ar e altas temperaturas. O objetivo deste trabalho foi pesquisar uma forma de umidificar o ar e avaliar a interferência desta umidificação na temperatura e umidade relativa na cortina de vento em pulverizador com tecnologia de assistência de ar. Os tratamentos corresponderam a diferentes ajustes e vazões de água de um dispositivo de umidificação, os quais foram relacionados às condições climáticas no momento da pesquisa. A pesquisa foi dividida em duas fases. Numa fase inicial exploratória o sistema de umidificação foi montado próximo a parede interna do duto de ar, pulverizando água com os bicos fixados a 45° em relação à direção do fluxo de ar. Nesta fase verificou-se que as gostas não seguiam o fluxo de ar, sendo direcionadas para a parede do duto, causando escorrimento e não obtendo alteração na temperatura e umidade na cortina de ar. Na segunda fase montou-se um ramal umidificador no centro do duto de ar, com os bicos pulverizando no sentido do fluxo. Os resultados mostraram que houve redução significativa da temperatura e aumento significativo da umidade relativa do ar na cortina de ar. A vazão de 0,48 L.min.-1 no sistema de umidificação proporcionou a melhor eficiência em relação à redução da temperatura na cortina de ar... / Air assisted ground applications are widespread and have been encouraged due to the potential for greater efficiency when compared to conventional ground application. Sprayers with airassisted boom are widely used in large-area cultures and in some situations of difficult penetration of droplets in the canopy of cultures, such as soybean and cotton. However, due to large climatic variations that occur during the application period, the operational return is affected by interruptions caused by low relative air humidity and high temperatures. This study aimed to investigate a way to humidify the air and to assess the interference of this humidification in the temperature and relative humidity in the air flow of air-assisted sprayers. The treatments corresponded to different water adjustments and flow rates of a humidification device, which were related to climatic conditions at the time of the survey. The study was divided into two phases. In an initial exploratory phase, the humidification system was mounted near the intern wall of the air duct, spraying water with nozzles set at 45° in relation to the direction of the air flow. At this stage, it was verified that the droplets did not follow the air flow, being directed towards the duct wall causing dripping and getting no alteration in temperature and in humidity of the air flow. In the second stage, a humidifier extension was mounted in the center of the air duct, with nozzles spraying in the flow direction. Results showed a significant reduction in temperature and a significant increase in the relative humidity of the air flow. A flow rate of 0.48 L.min.-1 in the humidification system provided the best efficiency regarding temperature reduction in the air flow, resulting in... (Complete abstract click electronic access below)
264

Umidificação e aquecimento do gás inalado em estação de anestesia com baixo fluxo de gases frescos com ou sem isolamento térmico do circuito ventilatório e com ou sem permutador de umidade e temperatura / The temperature and humidity of the inhaled gas in an anesthesia workstation using a low fresh gas flow with or without thermal insulation or heat and moisture exchanger

Oliveira, Sergius Arias Rodrigues de [UNESP] 27 August 2015 (has links) (PDF)
Made available in DSpace on 2016-06-07T17:12:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-08-27. Added 1 bitstream(s) on 2016-06-07T17:17:00Z : No. of bitstreams: 1 000857965.pdf: 2282169 bytes, checksum: f4ac41e4c98620fe8780047f83bd30b6 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Justificativa e objetivos: A intubação traqueal limita as funções normais de aquecimento e umidificação das vias aéreas superiores do paciente. Uma umidade mínima de gás inalado de 20 mgH2O.L-1 é recomendada para reduzir os efeitos deletérios do gás seco nas vias aéreas. A estação de anestesia Fabius GS Premium (Dräger Medical, Lübeck, Alemanha) tem placa de aquecimento embutida para aquecimento dos gases no circuito respiratório. A utilização de baixo fluxo de gás fresco (FGF) no circuito respiratório aumenta a temperatura e umidade do gás inalado, e um permutador de calor e umidade (PCU) pode ser usado também para umidificar e aquecer ainda mais o gás inalado. Os tubos corrugados do circuito respiratório são compostos de material com baixo isolamento térmico (IT), e a temperatura e a umidade dos gases no circuito são influenciadas pela temperatura fria da sala de operação. O objetivo deste estudo foi comparar a temperatura e a umidade dos gases inalados utilizando baixo FGF na estação de anestesia Fabius GS Premium com ou sem IT do circuito respiratório e com ou sem um PCU. Método: Quarenta e um pacientes adultos do sexo feminino foram distribuídos aleatoriamente, de acordo com os dispositivos acoplados ao circuito respiratório circular da estação de anestesia Dräger Fabius com baixo FGF (1 L.min-1), em quatro grupos: controle (n = 11), com IT (n = 10), com PCU (n = 10) ou com IT e PCU (ITPCU) (n = 10). A temperatura e umidade dos gases inalados foram mensuradas junto ao tubo traqueal utilizando um termo-higrômetro. As medições foram obtidas aos 10, 30, 60, 90 e 120 minutos da conexão das pacientes ao circuito respiratório. Resultados: Ao longo do experimento, a temperatura média do gás inalado foi maior nos grupos PCU e ITPCU (29,2 ± 1,3°C e 30,1 ± 1,2°C, respectivamente) em comparação com os grupos controle e IT (27,5 ± 1,0°C e 27,2 ± 1,1°C, respectivamente; p = 0,003). A umidade... / Background: Tracheal intubation limits the normal warming and humidifying functions of a patient's upper airways. An inhaled gas minimum moisture target of 20 mgH2O.L­1 is recommended to reduce the deleterious effects of dry gas on the airways. The Fabius GS Premium anesthesia workstation (Dräger Medical, Lübeck, Germany) has a built-in hotplate to heat gases in the breathing circuit. The use of a low fresh gas flow (FGF) in the breathing circuit increases the temperature and humidity of the inhaled gas and a heat and moisture exchanger (HME) can be used to further heat and humidify the inhaled gas. The corrugated tubes of the breathing circuit are composed of materials with low thermal insulation (TI), and the temperature and humidity of the gases in the circuit are influenced by the cold operating room temperature. The aim of this study was to compare the temperature and humidity of the inhaled gases from a low-flow Fabius anesthesia workstation with or without TI of the breathing circuit and with or without an HME. Methods: Forty-one adult female patients were randomly allocated into four groups according to the devices coupled to the breathing circuit from a Dräger Fabius GS Premium anesthesia workstation, used to ventilate their lungs using a breathing circle system with a low FGF (1 L.min­1): control (n = 11), with TI (n = 10), with an HME (n = 10) or with TI and an HME (TIHME) (n = 10). The temperature and humidity of the inhaled gases were measured close to the tracheal tube using a thermo-hygrometer. Measurements were obtained at 10, 30, 60, 90 and 120 minutes after connecting the patients to the breathing circuit. Results: The mean inhaled gas temperature was higher in the HME and TIHME groups (29.2 ± 1.3°C and 30.1 ± 1.2°C, respectively) compared with the control and TI groups (27.5 ± 1.0°C and 27.2 ± 1.1°C, respectively; P = 0.003). The mean inhaled gas absolute humidity was ...
265

Fisiologia, qualidade e produtividade da videira cv Syrah em diferentes estratégias de irrigação no semiárido / Physiology and yield of vine and grape quality of cv. syrah in different irrigation strategies in semiarid

Teixeira, Rafael Pombo [UNESP] 27 November 2015 (has links) (PDF)
Made available in DSpace on 2016-06-07T17:12:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-11-27. Added 1 bitstream(s) on 2016-06-07T17:17:12Z : No. of bitstreams: 1 000865199.pdf: 1408867 bytes, checksum: e3981c5854c46096bd529397e35281fb (MD5) / Para elaboração de vinhos finos de qualidade são necessários estudos aprofundados de diversas práticas agronômicas. Uma delas é o manejo da irrigação, principalmente quando a videira é cultivada em regiões com baixo índice pluvial como o Semiárido brasileiro. Hipoteticamente, o déficit hídrico a partir da fase fenológica de cacho fechado melhoraria a qualidade da uva para vinho. Com isso, o objetivo do trabalho foi avaliar a influência de estratégias de irrigação com restrição hídrica sobre a fisiologia e produtividade da videira e qualidade da uva para vinho cv. Syrah no Vale do Submédio São Francisco. O experimento foi realizado na Embrapa Semiárido, em Petrolina - PE, durante três consecutivos ciclos de produção (10 de abril a 9 de agosto de 2013 - ciclo 5, 8 de outubro de 2013 a 28 de janeiro de 2014 - ciclo 6, e 7 de maio a 3 de setembro de 2014 - ciclo 7), com 3 tratamentos e 4 repetições. Os tratamentos foram: irrigação plena (IP), onde a aplicação de água foi realizada por gotejamento com base na reposição da evapotranspiração da cultura, durante todo o ciclo de produção; irrigação com déficit controlado (IDC), onde a irrigação por gotejamento foi interrompida na fase de cacho fechado, mas eventualmente realizada conforme o monitoramento da umidade do solo na zona efetiva do sistema radicular da videira, e irrigação com déficit (ID), onde a irrigação por gotejamento foi interrompida na fase de cacho fechado, continuando sem irrigação até a colheita. Foram determinados o potencial hídrico foliar, trocas gasosas, composição isotópica do carbono na videira; os sólidos solúveis totais, pH, acidez total, antocianinas totais, flavonóides, polifenóis totais, taninos e atividade antioxidantes nas bagas; e o número de cachos por planta, massa de cachos por planta, massa média do cacho, e produtividade da videira. A IDC e ID ... / The production of fine quality wines requires detailed studies of various agronomic practices. One is the irrigation management, especially when the vine is grown in areas with low rainfall as the Brazilian semiarid. Hypothetically, the water deficit from the phenological stage of closed cluster improves grape quality for wine. Thus, the objective was to evaluate the effect of irrigation strategies with water deficit on plant physiology and yield, and berry quality of wine vine cv. Syrah in the Lower Middle São Francisco Valley. The experiment was carried out at Embrapa Tropical Semi-Arid, in Petrolina, State of Pernambuco, Brazil, for three growing seasons (April 10 to August 9, 2013 - seson 5, October 8, 2013 to January 28, 2014 - season 6, and 7 May to September 3, 2014 - season 7), with 3 treatments and 4 repetitions. The treatments were: full irrigation (FI), where the application of water by drippers was based on the replacement of the crop evapotranspiration throughout the whole season; regulated deficit irrigation (RDI), where irrigation was interrupted in the closed cluster phenological phase, but eventually performed as the soil moisture monitoring in the effective rooting depth of vine, and deficit irrigation (DI), where irrigation was interrupted in closed cluster phase, continuing without water application to harvesting. Measurements of leaf water potential, gas exchange, and carbon isotopic composition in the vine, total soluble solids, pH, titratable acidity, anthocyanins, flavonoids, total polyphenols, tannins, and antioxidants activity in the berries, and number of cluster per plant, cluster mass per plant, average cluster mass, and vine yield were performed. The irrigation strategies RDI e DI promoted moderate water stress in plants, reducing water consumption and weight of 100 berries for the three seasons, reducing the titratable acidity in seasons 5 and 6, and increasing ...
266

Utilização das equações de Navier Stokes com a parametrização convectiva BMJ para prognóstico de temperatura, umidade e vento sobre diferentes condições de estabilidade atmosférica utilizando o modelo regional ETA / Use of the Navier - Stokes BMJ with convective parameterization for forcast temperature, moisture and wind on different conditions of atmospheric stability using ETA regional model

Araújo, Janduy Guerra 26 October 2012 (has links)
Made available in DSpace on 2015-05-08T14:59:46Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2136442 bytes, checksum: 3d0ee50f2ecd5dc62121187d1ce4c080 (MD5) Previous issue date: 2012-10-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Here an approach is made on the impact of convective parameterization Bettes - Miller - Janjic (BMJ) on temperature, moisture and wind predicted by the model ETA. There are several papers in the literature that focus on this topic, few directed in particular to the state of Paraiba, but none of them uses the methodology described herein. It is known that below the cloud base (850hPa) profiles of temperature and moisture are not affected by the BMJ parameterization scheme because it does not consider the downdrafts of cold air to lower levels. Given this assumption, the methodology implemented in this work is to compare temperature, moisture and wind series provided by ETA with the respective synoptic analyzes of convective ERA-INTERIM/ECMWF for two contrasting situations. The model was configured with a horizontal resolution of 12 km and 30 vertical levels, covering the northeastern Brazil and the adjacent Atlantic and the focus of analysis is for three cities in the state of Paraiba. The results revealed that the predicted temperature to Joao Pessoa was slightly underestimated for low levels, while for the other two cities the model significantly overestimated the temperature at 1000 mb and slightly underestimated in 900 and 800mb. The predictions of moisture and wind were considered satisfactory when compared with the Analysis, and the best results were found at low levels. There were no significant differences between the estimates in both contrasting situations. / Nesta pesquisa é feita uma abordagem sobre o impacto da parametrização convectiva de Bettes Miller Janjic (BMJ) na temperatura, umidade e vento prognosticados pelo modelo ETA. Há vários trabalhos na literatura que focalizam este tema, poucos direcionados, em particular, para o estado da Paraíba, mas nenhum deles usa a metodologia descrita neste. É sabido que abaixo da base da nuvem (850hPa) os perfis de temperatura e umidade não são afetados pelo esquema de parametrização BMJ, pois ele não considera as correntes descendentes de ar frio para os baixo níveis. Diante deste pressuposto, a metodologia executada neste trabalho consiste em comparar as séries de temperatura, umidade e vento previstas pelo ETA com os respectivos dados sinóticos das análises do ERA-INTERIM/ECMWF para duas situações convectivas contrastantes. O modelo foi executado com resolução horizontal de 12 km e 30 níveis verticais, cobrindo o nordeste brasileiro e Oceano Atlântico adjacente e o foco das análises é para três cidades do estado da Paraíba. Os resultados revelaram que a temperatura prevista para João Pessoa foi ligeiramente subestimada para baixos níveis, enquanto que para as outras duas cidades o modelo superestimou significativamente a temperatura em 1000 mb e ligeiramente subestimou em 900 e 800mb. Os prognósticos de umidade e vento foram considerados satisfatórios quando comparados com as Analises, sendo que os melhores resultados foram encontrados em baixos níveis. Não houve diferenças significativas entre as previsões nos dois períodos analisados.
267

Análise crítica de incubadoras neonatais a partir de medições de parâmetros dos ambientes interno e externo / ASSESSMENT OF NEWBORN INCUBATORS BY MEASURING THE INTERNAL AND EXTERNAL ENVIRONMENT PARAMETERS

Costa, Enilson José Lima 02 October 2009 (has links)
Made available in DSpace on 2015-05-08T14:59:52Z (GMT). No. of bitstreams: 1 parte1.pdf: 1244500 bytes, checksum: 9e31d0b3f9a62bc311b6d1d5422ceaf4 (MD5) Previous issue date: 2009-10-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The survival chances of premature newborns increases when the air temperature and relative humidity of the incubator environment are under control. Newborn incubator is an electromedical equipment used for life maintenance of premature newborns. It provides a thermo-neutral environment, achieved by keeping the air temperature and relative humidity within a suitable range. This allows the baby to maintain the normal body temperature without excessive metabolic losses and contributes to a faster development and a smaller incidence of diseases. In this thesis, a measurement system capable to assess newborn incubators by measuring the internal and external environment parameters was designed and development. Also, it was developed a system to control the relative humidity of the incubator environment. In additional, a data acquisition software was developed to manager measured parameters inside the newborn incubator such as: air temperature, relative humidity, sound level and air flow velocity. Thus, it is possible to check if an incubator, under analysis, meets the requirements established by the NBR IEC 601-2-19 standard. Experimental tests were carried out in a time period of 96 hours and the measured data were collected at each 2 minutes. The results showed that all newborn incubators, which were assessed by the developed system, do not provide adequate environment for premature newborns as these incubators do not meet the NBR IEC 601-2-19 standard requirements. / As chances de sobrevivência dos recém-nascidos prematuros aumentam quando eles são colocados em um ambiente em que são controladas a temperatura e a umidade relativa do ar. A incubadora neonatal é um equipamento médico assistencial que serve para manter a vida de bebês prematuros onde estes encontram condições semelhantes às existentes no útero materno. Neste trabalho foi desenvolvido um sistema de aquisição de dados de temperatura e umidade, baseado em microcontrolador, para verificar as condições do ambiente proporcionado ao recém-nascido pela incubadora neonatal de acordo com a norma NBR IEC 601-2-19 e, um sistema de controle de umidade, baseado em microcontrolador, utilizando um motor de passo, com a finalidade de manter a umidade no interior da incubadora dentro de uma faixa pré-estabelecida. Isto tem por finalidade melhorar a qualidade de vida de recém-nascidos prematuros. Um software foi desenvolvido com a finalidade de unificar os dados coletados pelos sistemas de aquisição. A incubadora analisada é dotada de sistema de umidificação passivo. Realizaram-se medidas dos parâmetros temperatura, umidade, velocidade do fluxo de ar, concentração de oxigênio e nível sonoro no interior da incubadora, com água e sem água no reservatório de umidificação. Foram realizadas, também, medidas desses parâmetros no ambiente da Unidade de Tratamento Intensivo Neonatal. As medidas foram coletadas a cada 2 minutos durante 96 horas. Efetuaram-se testes para controlar a umidade relativa do ar no interior da incubadora. Verificou-se que os parâmetros analisados estão inter-relacionados e que os recém-nascidos prematuros foram expostos a níveis de ruídos intensos. Constatou-se que o sistema desenvolvido manteve a umidade controlada na faixa de 45 a 55 %UR. As incubadoras analisadas não oferecem um ambiente adequado à recuperação do recémnascido com base na norma.
268

Variabilidade espaço-temporal da emissão de CO2 do solo em curto período sob influência de eventos de precipitação /

Silva, Elienai Ferreira da. January 2016 (has links)
Orientador: Newton La Scala Júnior / Banca: Alan Rodrigo Panosso / Banca: Glauco de Souza Rolim / Resumo: A emissão de CO2 do solo (FCO2) em áreas agrícolas é um processo resultante da interação de diferentes fatores, tais como as condições de clima e solo. Nesse sentido, objetivou-se, com este estudo, investigar a variabilidade espaço-temporal da FCO2, temperatura (Tsolo), umidade (Usolo) e porosidade livre de água (PLA) do solo e suas interações, em área de reforma do canavial. O estudo foi conduzido em área de cana-de-açúcar sob reforma, na qual foi instalada malha amostral de 90 × 90 m2 contendo 100 pontos espaçados entre si em 10 m. Nestes pontos foram avaliadas a FCO2, Tsolo e Usolo em 10 avaliações ao longo de um período de 28 dias. Para as avaliações da FCO2, foi utilizado o sistema portátil LI-8100A. Concomitantemente à avaliação de FCO2, foram determinadas a Tsolo (termômetro integrante do sistema LI-8100A) e a Usolo (aparelho TDR). A emissão de CO2 e a Usolo foi maior no dia 276, com maior valor médio de 4,67 µmol m-2 s-1 e 31,75% em função das precipitações na área de estudo. Contrariamente os menores valor médios foram observados para PLA 19,17% e para a Tsolo 20,90 ºC. Os modelos de regressão linear utilizando somente a Usolo e a PLA explicaram 85% e 80%, respectivamente, da variabilidade temporal da FCO2, indicando que ao longo do tempo, a emissão de CO2 foi controlada pela variação do conteúdo de água e aeração do solo. Por outro lado, não foram encontrados modelos lineares ou quadráticos significativos (p>0,05) entre a FCO2 e a Tsolo. Os modelos ajustados para de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Soil CO2 emission (FCO2) in agricultural areas is a process thatresults of the interaction of different factors such as climate and soil conditions. In thissense, the aim of this study was to investigate the spatial and temporal variability ofFCO2, soil temperature (Tsoil), soil moisture (Msoil) and air-filled pore space (AFPS) andtheir interactions in a sugarcane field reform. This study was conducted in a 90 × 90-m sampling grid with 100 points spaced at distances of 10 m; at these points, 10measurements were performed over a period of 28 days. In order to measure theFCO2, it was used a LI-8100A. Along with the measurements of FCO2, Tsoil and Msoilwere also measured. It was observed an increase of 78% in FCO2 due to the rainfallin the study area. The linear regression models using only Msoil and AFPS explained85% and 80%, respectively, of the variability of FCO2, indicating that over the time, theemission of CO2 was controlled by varying the content of water and soil aeration. Theadjusted models to describe the spatial variability of FCO2, Tsoil, Msoil and AFPS werespherical and exponential. However, the spherical model was more predominant. Wedid not identify spatial variability using the maps for some days. Probably thishappened because we used the small scale. It can have collaborated for randombehavior. The spatiotemporal variability of CO2 emission, temperature, moisture andair-filled pore space was affected by rainfall in the study ar... (Complete abstract click electronic access below) / Mestre
269

Influência da umidade do solo na nodulação da soja (Glycine max (L.) Merril) /

Herdani, Egberto Egon de, 1956- January 2002 (has links)
Orientador: Raimundo Leite Cruz / Resumo: O presente trabalho teve por objetivo estudar os efeitos, de seis níveis de água no solo, na nodulação da soja (Glycine max (L.) Merril). Foi instalado um experimento em casa de vegetação localizada junto à Área experimental do Departamento de Engenharia Rural, da Faculdade de Ciências Agronômicas (FCA) - Campus Botucatu - SP, UNESP, durante os meses de novembro a dezembro/2001, em solo Latossolo Vermelho Escuro, textura média. O delineamento experimental foi de blocos casualizados com tratamentos em esquema fatorial 2 X 6 (dois níveis de inoculação - com e sem inoculação e seis níveis de irrigação - 30 %, 40 %, 50 %, 60 %, 70 % e 80 % da capacidade de campo), com seis repetições e uma variedade (IAC -18) um tipo de solo. As diferentes unidades experimentais, foram formadas por vasos plásticos impermeáveis contendo uma planta em cada vaso, onde foram avaliados, na floração, quando o processo de fixação de N2 atinge o ponto máximo, número e massa seca dos nódulos. Na planta, foram avaliados, massa seca da parte aérea e das raízes e nitrogênio na planta, pode-se concluir que as plantas responderam positivamente ao aumento do nível de água no solo em relação ao desenvolvimento da parte aérea e radicular . Quando inoculadas apresentaram maior teor de nitrogênio da parte aérea. / Abstract: The aiming of the work was study the efects of six soil moisture levels on soy nodulation (Glycine max (L.) Merril). A greenhouse experiment was installed at Department of Field Engineering of Faculdade de Ciências Agronômicas (FCA) in campus Botucatu-SP, UNESP, during november/2001 until december/2001, in na Oxisol medium texture. The experimental design was randomized blocks with 2 X 6 outlined treatments ( 2 inoculation levels- with and without inoculation and 6 irrigation levels: 30%, 40%, 50% 60%, 70% and 80% of field capacity), it was used 6 repetitions with IAC-18 variety. The different experimental units were formed by impermeable vases with one plant each. These vases were used for avaliation of, during flowering, N fixation (maximum rate) levels, number and dry mass of the nodules. It was analyzed as well, the dry matter and N levels of the aerial part of the plant and the root system. It could be concluded that there were, in all treatments, a plant positive response with the increment of water available in soil and a better development in inoculated plants. / Mestre
270

Irrigação deficitária em videira de vinho cv. Syrah durante o período chuvoso no semiárido /

Correia, Joselina de Souza, 1978. January 2012 (has links)
Orientador: Luís Henrique Bassoi / Banca: Raimundo Leite Cruz / Banca: Antonio Odair Santos / Resumo: As disponibilidades de radiação solar e de água para irrigação contribuem para a produção de uvas ao longo do ano no Vale do Submédio São Francisco. Diante da expansão da vitivinicultura nesta região, a demanda por pesquisas em relação ao manejo adequado e prático da videira para a região semiárida brasileira tem aumentado. Desta forma, o presente trabalho teve o objetivo de avaliar a influência de estratégias de irrigação na cultura da videira de vinho, e suas possíveis influências na produtividade e qualidade das uvas. O experimento foi conduzido na Embrapa Semiárido, em Petrolina -PE, entre 10 de novembro de 2010 a 28 de fevereiro de 2011, com a videira cv. Syrah/Paulsen 1103, plantada em espaçamento de 1 x 3 m, em um Argissolo Vermelho Amarelo Eutrófico Latossólico. O sistema de irrigação utilizado foi o gotejamento, com emissores espaçados em 0,5 m na linha de plantio, com vazão de 2,5 L.h-1. O delineamento utilizado foi o de blocos casualizados, com 3 tratamentos e 4 repetições. Os tratamentos foram: 1- irrigação plena (IP), irrigação realizada com base na reposição da evapotranspiração da cultura (ETc), durante todo o ciclo de produção; 2 - irrigação com déficit controlado (IDC), irrigação interrompida aos 65 dias após a poda de produção (dapp), porém com irrigações aos 91, 92 e 93 dapp; e 3 - irrigação deficitária (ID), irrigação interrompida aos 65 dapp até a colheita aos 110 dapp. A ETc foi estimada pela relação entre evapotranspiração de referência (ETo), e o coeficiente de cultura (Kc). O potencial hídrico foliar (Ψfoliar) foi medido em cada tratamento, do estádio fenológico de maturação até o estádio de cachos maduros. Durante o experimento, ocorreu uma precipitação total de 252 mm. A ETc durante... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The availability of solar radiation and water for irrigation contribute to the wine grape production throughout the year in the Lower Middle São Francisco Valley. In consequence of increase of vine growing area in this region, the research demand about suitable and feasible vine water management in the Brazilian semi-arid region has increased. Thus, this study aimed to evaluate the influence of irrigation strategies in vineyards, and their possible effects on yield and quality of wine grapes. The experiment was carried out at Embrapa Tropical Semi-arid, in Petrolina, State of Pernambuco, Brazil, from November 10, 2010, to February 28, 2011. The grapevive cv. Syrah, grafted on Paulsen 1103, was planted at a spacing grid of 1 x 3 m, in a Argissolo Vermelho Amarelo Eutrófico Latossólico. Drip irrigation was used, with emitters spaced 0.5 m within the plant row, with 2.5 L.h-1 flow. The design was a randomized complete block with three treatments and four replications. The treatments were: 1 - full irrigation (FI), where irrigation was performed based on crop evapotranspiration (ETc, mm) during all growing season, without water restriction to the vines; 2 - regulated deficit irrigation (RDI), where irrigation was performed based on ETc until 65 days after pruning (dap), but performed at 91, 92, and 93 dap and 3 - deficit irrigation (ID) - where irrigation interrupted at 65 dap until harvest at 110 dap. The ETc was estimated by the relationship between reference evapotranspiration (ETo), and crop coefficient (kc) for each phenological phase of vine. The leaf water potential (Ψpd) was measured... (Complete abstract click electronic access below) / Mestre

Page generated in 0.0362 seconds