• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 38
  • Tagged with
  • 38
  • 38
  • 28
  • 14
  • 13
  • 13
  • 12
  • 10
  • 10
  • 9
  • 8
  • 7
  • 7
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Validação de processos

Ribeiro, Sonia Hilst 12 February 1999 (has links)
Orientador: Jose Ferreira de Carvalho / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Matematica, Estatistica e Computação Cientifica / Made available in DSpace on 2018-07-26T17:14:51Z (GMT). No. of bitstreams: 1 Ribeiro_SoniaHilst_M.pdf: 4463796 bytes, checksum: d18c1ed5b2b75696da01b02f49c3e800 (MD5) Previous issue date: 1999 / Resumo: A qualificação ou caracterização de processos produtivos, seguida da validação, será apresentada neste trabalho como uma ferramenta para o gerenciamento efetivo de um processo, que deve ser visto como parte da estratégia de sucesso de negócio em uma indústria. Esse sistema: pode ser utilizado para qualquer tipo de processo, desde que sejam feitas as adequações necessárias ao nível de qualidade requerido. O sistema aqui abordado contempla os requisitos necessários para os processos de fabricação de produtos farmacêuticos e / ou medical devices, cujas exigências são especificadas pelo FDA. O trabalho apresentado segue o seguinte esquema: Caracterização do sistema de medidas que, para processos farmacêuticos, significa validação do sistema analítico e da metodologia analítica. Como é possível perceber, sem o conhecimento da qualidade do sistema de medidas, é impossível separar o sinal do processo do erro normalmente presente em qualquer sistema de medidas. Validação do processo, que inclui a qualificação da instalação, da operação e do desempenho dos equipamentos e, em seguida, validação de processo e produto. Esta etapa é também um requisito do FDA e visa assegurar a estabilidade de produção, eliminando-se todas as fontes,. de variabilidade devido a causas assinaláveis. É a etapa de caracterização do processo em que todo o processo deve ser contemplado e documentado,. de forma especificada, pelo FDA. A estabilidade do processo é determinada nesta etapa e documentada para referência futura. As próximas etapas seriam otimização do processo e validação de limpeza. Otimização é a fase em que as variáveis do processo são estudadas, e seus efeitos avaliados para buscar as alterações que forneçam melhor resposta com menor custo e em menor tempo. E a "validação de limpeza", que previne a contaminação cruzada. Estes dois últimos itens não foram incluídos neste trabalho por serem ambos assuntos tão extensos que justificariam um outro trabalho de tese / Abstract: Not informed / Mestrado / Mestre em Qualidade
2

Conceitos de validação de metodos cromatograficos, aplicados na determinação de Omeprazol e impurezas em capsulas e comprimidos

Ribani, Marcelo 03 August 2018 (has links)
Orientador: Carol H.Collins / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-03T21:01:03Z (GMT). No. of bitstreams: 1 Ribani_Marcelo_M.pdf: 3845224 bytes, checksum: a4ef0a9577a81af2074343864b9bde8c (MD5) Previous issue date: 2004 / Mestrado
3

Determinação de residuos de herbicidas em aguas utilizando extração em fase solida seguida de separaçaõ por cromatografia liquida e alta eficiencia

Pinto, Glaucia Maria Ferreira 25 July 2018 (has links)
Orientador: Isabel Cristina Sales Fontes Jardim / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-25T00:06:55Z (GMT). No. of bitstreams: 1 Pinto_GlauciaMariaFerreira_M.pdf: 2660436 bytes, checksum: ff08d259972360edc1f0679136068d33 (MD5) Previous issue date: 1999 / Mestrado
4

Padronização de metodo utilizando a cromatografia liquida de alta eficiencia para a determinação de nicotina e cotinina em plasma de tabagistas

Barbieri, Deise 26 February 2003 (has links)
Orientador: Heitor Moreno Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-04T01:16:59Z (GMT). No. of bitstreams: 1 Barbieri_Deise_M.pdf: 2646493 bytes, checksum: 13275acee4df394e8a7125b74cbe54eb (MD5) Previous issue date: 2003 / Resumo: O tabagismo é considerado um problema de saúde pública, uma vez que é responsável por cerca de 4 milhões de morte anualmente em todo o mundo. Nos últimos anos tem ocorrido um aumento dramático na procura por métodos de quantificação da nicotina e outros derivados do tabaco, na intenção de se avaliar as terapias de cessação do hábito de fumar. Nesse trabalho foram feitas a padronização e a validação de uma metodologia para a quantificação da nicotina e de seu principal metabólito, cotinina, em 1 mL de. plasma de tabagistas com adesivo transdérmico de nicotina, após submetidos a um período de abstinência ao tabaco de 24 horas. O plasma foi extraído com diclorometano e analisado por cromatografia líquida de alta eficiência (CLAE) em sistema cromatográfico da Shimadzu, Japão, em coluna LUNA (Phenomenex , USA), 150 mm de comprimento, 4,6 mm de diâmetro interno e 5 f.tm de partícula. Nas condições padronizadas a nicotina, a cotinina e o 2-fenilimidazol (padrão interno) eluíram em 4,6 :t 0,1 min., 6,2 :t 0,1 mino e 15,2 :t 0,1 min., respectivamente. A linearidade do método foi observada com amostras de plasma adicionadas com padrões nas concentrações de 10 a 50 ng/mL para a nicotina e de 10 a 500 ng/mL para a cotinina, mostraram -se adequadas aos propósitos do estudo, com coeficientes de determinação de 0,9928 para a nicotina e 0,9978 para a cotinina. A recuperação média do estudo foi de 75,8% e 77,7% para a nicotina e a cotinina, respectivamente. A precisão intra-ensaio teve coeficiente de variação médio de 6,3% (:tO,01) para a nicotina e 7,0% (:tO,01) para a cotinina, e a precisão interensaio apresentou coeficientes de variação médios de 7,1 (:t 0,02) e 7,6 (:t 0,02) para a nicotina e a cotinina, respectivamente. Os limites de detecção foram 5 e 3 ng/mL e de quantificação 10 e 5 ng/mL para a nicotina e a cotinina. O método mostrou-se adequado aos estudos de exatidão por apresentar variação entre a concentração teórica e a calculada pelo método inferior a 10 %. O estudo de estabilidade comprovou que as amostras podem ser armazenadas em geladeira por um período de até 3 meses sem apresentarem perdas dos princípios ativos maior que 10%. O método forneceu uma separação adequada da cafeína, considerada o principal contaminante da amostra. A técnica padronizada e validada permitiu a análise de amostras de tabagistas com adesivo transdérmico de 21 mg e a possibilidade de realização de estudos futuros correlacionando a farmacocinética e a farmacodinâmica da nicotina com o rítmo circadiano da pressão arterial / Mestrado / Farmacologia / Mestre em Farmacologia
5

Validação de metodos laboratoriais : avaliação do sistema BAX'Marca Registrada' de analise de Salmonella sp em alimentos por reação de polimerase em cadeia (PCR) / Laboratorial method validation : evaluation of BAX system'Trade Mark' for Salmonella sp in food for polymerase chain reaction

Kushida, Marta Mitsui 15 August 2005 (has links)
Orientador: Lucia Regina Durrant / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-05T00:51:57Z (GMT). No. of bitstreams: 1 Kushida_MartaMitsui_D.pdf: 1944227 bytes, checksum: 5343a021abfd5cdca334152ade81151c (MD5) Previous issue date: 2005 / Resumo: Salmonella é uma das principais causas de doenças transmitidas por alimentos (DTAs) em todo o mundo, sendo objeto de preocupação dos principais organismos internacionais relacionados com a saúde pública. A análise deste patógeno faz parte da rotina de qualquer laboratório de controle de qualidade de alimentos e, embora exista uma grande variedade de métodos alternativos, a maioria desses laboratórios ainda utiliza o método cultural tradicional, caro, lento e trabalhoso. A principal barreira à disseminação dos métodos alternativos é o fato de serem presuntivos e, em caso positivo, exigirem o retorno ao método tradicional, para confirmação. Recentemente, entretanto, foi introduzida no Brasil uma técnica que não padece dessa desvantagem, o sistema BAX® de análise de Salmonella por reação de polimerase em cadeia (PCR). Além de ser confirmativo, o BAX® ainda é bem mais rápido, permitindo a obtenção dos resultados em 30h e com o mínimo de manipulação, pois é totalmente automatizado. A substituição do método tradicional pelo BAX® pode elevar significativamente a capacidade de análise dos laboratórios, porém, é um sistema novo, ainda pouco utilizado no país, sendo importante uma avaliação do seu desempenho na análise de produtos brasileiros, objetivo do presente trabalho. Para tanto realizou-se uma avaliação do Sistema BAX® em comparação com o método cultural tradicional, analisando 708 amostras de 22 categorias de alimentos em relação à presença de Salmonella pelos dois métodos, o que permitiu a determinação dos parâmetros de desempenho do sistema BAX®. Os resultados obtidos indicaram sensibilidade de 100%, especificidade de 98,6%, taxa de falsos positivos de 1,4% e taxa de falsos negativos de 0% / Abstract: Salmonella sp is one of most important food born microorganism in all the world, and it always has been focused among international public health organs. The food analysis for this pathogen is a subject of routine in all food quality control laboratories, and, besides there are several alternative methods for Salmonella sp detection, but most of the laboratories still work with the traditional technique of detection, which is very expensive and time consuming. The barrier to alternatives methods is the fact that most of them are considered presumptive, and need the traditional technique to confirm the positives results. An alternative technique that does not present the step of confirmation was recently, introduced in Brazil, the BAX¿ System for Salmonella sp, which works by polymerase chain reaction (PCR). It is a very quick detection method, safety, accurate which shows the analysis result in 30 hours, utilizing very few manipulation of samples, since is automatized. The substitution of traditional Salmonella sp detection method for BAX¿ system, can increase significantly the laboratories analysis capacity, but as it is a very new technique, is still unknown in our country. In despite of this, it is important to evaluate its performance in Brazilian food products, which is the aim of this research. A evaluation of BAX¿ system, compared with the Salmonell traditional method was then carried out, using 708 samples of 22 different food categories. The results showed sensibility of 100%, specificity of 98,6%, falsepositives ratio of 1,4% and false-negatives ratio of 0% for BAX¿ system / Doutorado / Doutor em Ciência de Alimentos
6

Metodologia para acreditação dos métodos de análise de sólidos suspensos e dissolvidos em águas

Gonçalves, Rute Isabel Landeiro de Sousa January 2009 (has links)
Estágio realizado na Instituto Nacional de Saúde Doutor Ricardo Jorge, I.P. (INSA, I.P.). e orientado pelo Doutora Ana Margarida Heitor / Tese de mestrado integrado. Engenharia Química. Faculdade de Engenharia. Universidade do Porto. 2009
7

Desenvolvimento e validação de metodos para a determinação de agrotoxicos em agua e solo das areas de recarga de Aquifero Guarani, na região das nascentes do Rio Araguaia, MT/GO / Development and validation of methods for determination of pesticides in water and soil from the Guarani Aquifer recharging, area, near the source Araguaia River, MT/GO

Morais, Lais Sayuri Ribeiro de 15 August 2018 (has links)
Orientadore: Isabel Cristina Sales Fontes Jardim, Sonia Claudia do Nascimento de Queiroz / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-15T20:18:30Z (GMT). No. of bitstreams: 1 Morais_LaisSayuriRibeirode_D.pdf: 1161986 bytes, checksum: 39b7f874268f505aa38cca5ac6e52461 (MD5) Previous issue date: 2009 / Resumo: A região das nascentes do Rio Araguaia, na divisa dos estados de Goiás e Mato Grosso abriga uma porção das áreas de recarga do Aquifero Guarani, o qual é um dos maiores sistemas aquíferos do mundo e representa a principal fonte de água potável na região. Este reservatório pode estar comprometido pelo uso crescente de agrotóxicos nas plantações de soja e de milho da região. Diante deste cenário, neste trabalho foram desenvolvidos métodos analíticos para a determinação dos agrotóxicos imazetapir, nicossulfurom, imazaquim, carbofuram, atrazina, linurom, clorimurom-etil e diflubenzurom, utilizados em culturas de milho ou de soja. Para separação, identificação e quantificação dos agrotóxicos foram utilizadas a Cromatografia Líquida de Alta Eficiência com detecção por arranjo de diodos e a Cromatografia Líquida acoplada por Fonte de Ionização por Eletronebulização à Espectrometria de Massas em série. A extração em fase sólida (SPE), com cartuchos C18, foi selecionada e otimizada para a extração dos agrotóxicos em amostras de água. Para o preparo das amostras de solo foram estudadas as técnicas de extração por agitação mecânica, por banho ultrassônico e assistida por micro-ondas industrial e caseiro. Os métodos desenvolvidos foram validados obtendo-se limites de quantificação (LQ) em água, na faixa de 0,015-0,1 ng mL empregando SPE-HPLCDAD e 0,01 ng mL com SPE-LC-ESI-MS/MS. Com a extração assistida por micro-ondas caseiro e LC-ESI-MS/MS foram obtidos LQ de 1 ng mL para todos os agrotóxicos em solo. Em todos os métodos validados, os valores de recuperação dos agrotóxicos em um mesmo dia e em dias diferentes, ficaram dentro da faixa aceitável de 70-120 %. Os ensaios de repetitividade e de precisão intermediária para todos agrotóxicos apresentaram coeficientes de variação inferiores ao limite aceito de 15 %. Os métodos SPE-HPLC-DAD e SPE-LC-ESI-MS/MS foram aplicados em análises de amostras de água da região em estudo, verificando-se que a maioria dos agrotóxicos analisados encontrava-se abaixo do limite máximo de resíduos de 0,1 ng mL. Não foram detectados agrotóxicos nas amostras de solo coletadas em outras duas regiões com cultivo de milho e soja, empregando a extração assistida por micro-ondas caseiro e LC-ESIMS/ MS. Os parâmetros físico-químicos determinados para o imazetapir, imazaquim, nicossulfurom e clorimurom-etil mostraram que eles apresentam pouca afinidade pelo solo estudado, tendo grande disponibilidade para lixiviação, em conformidade com o índice de GUS / Abstract: The area near the Araguaia River, between Goiás and Mato Grosso States, is the location of a portion of the recharging of the Guarani Aquifer, which is one of the world¿s largest aquifer systems and an important source of drinking water. This reservoir could be threatened by the widespread use of pesticides in maize and soybean cultivation in this area. Thus, this work developed analytical methods for the determination of imazethapyr, nicosulfuron, imazaquin, carbofuran, atrazine, linuron, clorimuronethyl and diflubenzuron, pesticides used in maize and soybean cultivation. Pesticide separation, identification and quantification were performed using High-Performance Liquid Chromatography with Diode Array Detection (HPLC-DAD) and Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry (LC-ESI-MS/MS). Solid Phase Extraction (SPE) with C18 sorbents was optimized for sample extraction from water. Soil samples were extracted by mechanical shaking, sonication or microwave-assisted extraction with industrial and home microwave ovens. Methods were validated resulting in limits of quantification (LOQ) for the pesticides in water in the range of 0.015-0.1 ng mL, using SPE-HPLC-DAD, and 0.01 ng mL using LC-ESI-MS/MS. LOQ of 1 ng mL for all pesticides in soil were achieved using the home microwave oven and LC-ESI-MS/MS. Recoveries for pesticides with all methods were in the range 70-120 %. Relative standard deviations for repeatability and intermediate precision were less than 15 %. SPEHPLC- DAD and LC-ESI-MS/MS were employed for the analysis of samples of water from the recharge area and most of the pesticides were detected at concentrations below the minimum residue limit (MRL) of 0.1 ng mL established by the European Community. The home microwave oven and LC-ESI-MS/MS were used for the analysis of soil samples from two other regions of Brazil and the pesticides were not detected in these samples. Adsorption and desorption parameters were determined for imazethapyr, imazaquin, nicosulfuron and chlorimuron-ethyl, indicating that these pesticides have little affinity for the soil of the region of the Guarani Aquifer recharge, and show significant leaching potential, according to the ground water ubiquity score (GUS index) for these pesticides / Doutorado / Quimica Analitica / Doutor em Ciências
8

Tradução, adaptação cultural e validação do Female Sexual Function Index (FSFI) para lingua portuguesa / Validation of Famale Sexual Function Index into the Portuguese

Thiel, Rosane do Rocio Cordeiro 25 June 2008 (has links)
Orientadores: Paulo Cesar Rodrigues Palma, Miriam Dambros / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-11T11:35:32Z (GMT). No. of bitstreams: 1 Thiel_RosanedoRocioCordeiro_D.pdf: 1514733 bytes, checksum: edd855efa491eefd2b54bddb5c81e6be (MD5) Previous issue date: 2008 / Resumo: A avaliação da qualidade de vida tem sido cada vez mais utilizada na área da saúde e tornou-se uma ferramenta de mensuração desde que foi considerada medida válida e reprodutível. Uma das formas mais empregadas de avaliação são os questionários. A grande maioria dos instrumentos foi formulada na língua inglesa mas, em virtude do crescente número de ensaios clínicos multicêntricos, surgiu a necessidade de desenvolver medidas para utilização em outros idiomas. Também não basta que o instrumento seja simplesmente traduzido, é necessário realizar, além da tradução e da adaptação transcultural, a avaliação de suas propriedades de medida. Tendência atual propõe a utilização de instrumentos validados em oposição ao desenvolvimento de novas escalas. O crescente interesse pelo estudo da sexualidade encontra como obstáculo, além da dificuldade de avaliar os diferentes aspectos da resposta sexual, grande diversidade de métodos, o que dificulta a generalização de informações e compromete as propostas de tratamento. O intuito desse trabalho foi realizar a validação de um questionário para avaliar a resposta sexual feminina de mulheres e desse processo resultou um artigo científico. A escolha do instrumento considerou a literatura científica até junho de 2006 e até essa data não havia registro de instrumento específico e validado na Língua Portuguesa para avaliar a resposta sexual na mulher. O ¿Female Sexual Function Index (FSFI)¿ foi escolhido porque é questionário breve e multidimensional que avalia a resposta sexual feminina, considerando seus domínios. O questionário original foi traduzido para Língua Portuguesa por dois tradutores brasileiros, retrovertido por dois tradutores nativos na língua inglesa. As diferenças foram harmonizadas por profissionais da saúde bilíngües e a versão originada foi pré-testada. A versão final em português (do Brasil) foi aplicada em 100 mulheres, juntamente com um questionário de avaliação da qualidade de vida SF-36. A mediana de idade foi de 21 anos (variou de 19 a 69 anos). Foram testadas propriedades psicométricas: confiabilidade [consistência interna (Alfa de Cronbach), re-teste (Coeficiente de Correlação Intraclasses)], validade de constructo (Coeficiente de Correlação de Pearson) e concorrente (Mann-Whitney e Kruskal-Wallis). Após quatro semanas da primeira entrevista, foi realizado o re-teste (FSFI). O Alfa de Cronbach geral foi 0,96 e a confiabilidade foi 1,00. Dados finais mostraram que a versão do FSFI em Português é válida para avaliação da resposta sexual em mulheres brasileiras e está indicado para uso em pesquisas clínicas / Abstract: The evaluation of the quality of life (QoL) has been increased in use in the Health area and has become a measurement tool since it was considered as a valuable and reproducible measure. One of the most used ways of evaluation is the questionnaire. The majority of the instruments were questioned in the English language but considering the multicentrics clinical essays, it emerged the need of developing measures of usage in other languages. It is not enough that the instrument would be simply translated, it is necessary to adequate the evaluation of the properties of the measurement, besides the translation and the transcultural adaptations implied. The actual trend proposes the usage of instruments validated in contrast of the development of new scales. The increased interest in the study of sexuality is seen as an obstacle, not mentioning the difficulty in evaluate the different aspects of the sexual response, big diversity of methods that come as a complexity of the generalization of information and endangers the proposals of the treatment. The aim of this work is to achieve the validation of a questionnaire to evaluate the female sexual response of women and, from this process it comes out a scientific article. The choice of the instrument considered the scientific literature until June 2006 and, until this present date, there was no register of a specified instrument and validated in Portuguese language to evaluate the sexual response in women. The ¿Female Sexual Function Index (FSFI)¿ was chosen because it is a brief and multidimensional questionnaire that evaluates the female sexual response, considering its domains. The original questionnaire was translated to Portuguese language by two Brazilian translators, retroverted by two English translators. Health bilingual professionals harmonized the differences and the original version was pre-tested. The final version in Portuguese (from Brazil) was applied in a hundred women, as well as the evaluation questionnaire of life quality SF-36. The age average was 21 years old (it varied from 19 to 69). It was also tested psychometrical properties: reliability [internal consistency (Alpha of Cronbach), re-test (Interclass Correlation Coefficient)], validation of constructo (Pearson Correlation Coefficient), and competence (Mann-Whitney and Kruskal-Wallis). After four weeks of the first interview, the re-test was re-applied (FSFI). The general Alpha of Cronbach was 0,96 and the reliability was 1,00. Final datas showed that the version of FSFI in Portuguese is valid for the evaluation of sexual response in Brazilian women and it is certainly indicated to the use in clinical researches / Doutorado / Pesquisa Experimental / Doutor em Cirurgia
9

Obtenção e aplicação de padrões de isoflavonas de soja / Obtention and application of isoflavone standards from soybeans

Ribani, Marcelo 12 August 2018 (has links)
Orientadores: Carla Beatriz Grespan Bottoli, Carol Hollingworth Collins / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-12T11:07:55Z (GMT). No. of bitstreams: 1 Ribani_Marcelo_D.pdf: 2298112 bytes, checksum: 0ec75ae8ab9c973ad70afa69a5098302 (MD5) Previous issue date: 2008 / Resumo: O uso de padrões analíticos em análises cromatográficas é de fundamental importância para obter resultados analíticos confiáveis tanto em processos de validação de métodos quanto em análises rotineiras. Porém, o custo dos padrões de referência e sua disponibilidade para comercialização tornam o processo analítico muito caro e demorado. Neste trabalho foram obtidos padrões analíticos de isoflavonas de soja através da cromatografia líquida preparativa. Inicialmente foi desenvolvida uma método analítica por cromatografia líquida de alta eficiência, para separação e identificação de isoflavonas em extrato seco de soja. A seguir, foi realizada a transposição da escala analítica para a escala preparativa, iniciando pelo método da transposição direta. A caracterização e a pureza das isoflavonas obtidas foram verificadas a partir da pureza cromatográfica e pelos espectros na região do ultra violeta e visível, complementados pela espectrometria de massas e pela ressonância magnética nuclear. Os padrões obtidos por cromatografia preparativa apresentaram um teor de pureza de 93,1 % para daidzina, 99,8 % para daidzeína, 89,5 % para genisteína e 87,7 % para glicitina, permitindo, assim, o seu uso como padrões em análises rotineiras. Para demonstrar a aplicabilidade dos padrões obtidos, foi desenvolvido e validado um método para extração, hidrólise ácida e determinação das isoflavonas agliconas contidas em grãos de soja. Os resultados do conteúdo total de isoflavonas foram 283,5 ± 10,7 mg/100 g para soja não transgênica (BRS133) e 228,2 ± 13,8 mg/100 g para soja transgênica (BRS245RR), demonstrando diferenças significativas no conteúdo destas duas variedades de soja. / Abstract: The use of analytical standards in chromatographic analyses is very important to get trustworthy analytical results for validation of methodologies and for routine analyses. However, the cost of the available reference standards is high, prejudicing the overall analytical process. In this work, a transposition from analytical to preparative scale was carried out to obtain analytical standards of isoflavones from soybeans. An analytical methodology using high performance liquid chromatography (HPLC) was developed for separation and identification of isoflavones in dry soy extract. The transposition of the analytical parameters to the preparative scale was done initially through direct transposition. The characterization and purity of the isoflavones was determined by HPLC with spectra from a DAD detector, complemented by mass (MS+/-) and nuclear magnetic resonance spectrometries. The resulting isoflavone purities, after preparative separation and lyophilization, were 93.1 % for daidzin, 99.8 % for daidzein, 89.5 % for genistein and 87.7 % for glycitin, allowing their use as standards in routine analyses. To demonstrate the applicability of the standards obtained, an approach for extraction, acid hydrolysis and determination of the total amounts of isoflavone aglicones in soybeans was developed and validated. The results indicated total isoflavone contents of 283.5 ± 10.7 mg/100 g for non-transgenic (BRS133) and 228.2 ± 13.8 mg/100 g for transgenic (BRS245RR) soybeans, demonstrating significant differences in the isoflavone content of these two different soybeans. / Doutorado / Quimica Analitica / Doutor em Ciências
10

Validação de métodos para análise e estudos de estabilidade de anti-retrovirais em preparações farmacêuticas / Validation of analytical methods for analysis and stability studies of anti-retrovirais in pharmaceutical preparations.

Taborianski, Andréia Montoro 11 August 2003 (has links)
A síndrome da imunodeficiência adquirida é causada pelo vírus da imunodeficiência humana e é caracterizada por provocar depleção física e funcional do sistema imune do organismo, através da infecção citopática de células CD4+. Muitos fármacos anti-retrovirais tem sido desenvolvidos e estão disponíveis comercialmente. Para atuar no controle de qualidade de medicamentos deve-se continuamente estudar o desenvolvimento e a validação de novas metodologias para quantificação de fármacos, para serem aplicadas nos estudos de estabilidade de formulações farmacêuticas e na análise de produtos de degradação. Neste trabalho foram utilizadas duas técnicas analíticas, a espectrofotometria direta no UV/VIS e a cromatografia líquida de alta eficiência (CLAE), para a determinação quantitativa de zidovudina (AZT) e estavudina (d4T).em medicamentos. Ambos os métodos foram validados com relação à linearidade, exatidão, precisão, especificidade e limite de detecção e quantificação. O método validado para a CLAE foi também empregado para a determinação quantitativa da timina, produto de degradação do AZT e da d4T. A metodologia validada por CLAE foi utilizada na realização de estudos de estabilidade acelerada dos anti-retrovirais contidos nas diferentes preparações farmacêuticas. Realizou-se o estudo da estabilidade em três diferentes condições: temperatura ambiente, 40 oC / 75% UR e 50 oC / 90% UR. Tanto a zidovudina (Fabricante A) e estavudina (Fabricante B) apresentaram decaimento cinético de zero ordem com prazos de validade a 50 oC / 90% UR de 10, 3 e 2 meses, respectivamente. / The acquired immunodeficiency syndrome is characterized by causing physical and functional depletion of the organism’s immune system, through the cytophatic infection of CD4+ cells. Several antiretroviral drugs has been developed and commercially made available. In order to assure the quality control of drugs it is necessary to develop and validate new analytical methodologies to perform the quantitative determination of drugs and stability studies of pharmaceutical formulations by determining the drug itself and its degradation products. In this research two analytical techniques, direct UV/VIS spectrophotometry and high performance liquid chromatography (HPLC), were used for the quantitative determination of zidovudine (AZT) and stavudine (d4T) in pharmaceutical preparations. Both methods were validated and parameters like linearity, precision, accuracy, specificity, limit of detection and limit of quantification, were determined. The validated HPLC method was also applied for quantitative determination of timine, a degradation product of AZT and d4T. The validated HPLC method was applied to accelerate stability studies of AZT and d4T in different pharmaceutical preparations. The stability studies were performed at three different conditions: room temperature, 40 oC / 75% RH and 50 oC / 90% RH. Both AZT and d4T (Industry A) and d4T (Industry B) pharmaceutical preparations presented a zero order degradation reaction. The three formulations presented a shelf-life of 10, 3 and 2 months, respectively, at 50 oC / 90% RH.

Page generated in 0.1322 seconds