• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1581
  • 34
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 1651
  • 1140
  • 731
  • 478
  • 238
  • 237
  • 208
  • 201
  • 198
  • 163
  • 160
  • 151
  • 150
  • 141
  • 140
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
391

Níveis de dano econômico e planos de amostragem sequencial para Frankliniella schultzei em cultivos de melancia

Pereira, Poliana Silvestre 12 August 2016 (has links)
O tripes Frankliniella schultzei é uma importante praga da melancia. Porém, ainda não foram determinados níveis de dano econômico e planos de amostragem para esta praga nessa cultura. Assim, este trabalho teve por objetivo determinar níveis de dano econômico e planos de amostragem sequencial para F. schultzei em situações de preço baixo, médio e alto do fruto. O ataque de F. schultzei às plantas de melancia no estádio vegetativo reduziu a produtividade da cultura. Os níveis de dano econômico foram 0,09, 0,04 e 0,02 tripes por folha quando o preço da melancia é baixo, médio e alto, respectivamente. Os três planos de amostragem sequencial para F. schultzei, gerados para cada nível de dano econômico, tomam decisões semelhantes e mais rápidas do que o plano convencional, sobretudo quando a densidade da praga é alta. Os três níveis de dano econômico e os planos de amostragem sequencial gerados neste trabalho podem ser incorporados a programas de manejo integrado de pragas da cultura de melancia por eles possibilitarem uma decisão de controle rápida e adequada para F. schultzei. / The thrips Frankliniella schultzei is an important watermelon pest. Nevertheless, economic injury levels and sampling plans for this pest have not yet been determined for this crop. Thus, the objective of the present study was to determine the economic injury levels and develop sequential sampling plans for F. schultzei in conditions of low, medium, and high fruit prices. The attack of F. schultzei on watermelon plants during the vegetative stage reduced the crop’s productivity. The economic injury levels were 0.09, 0.04, and 0.02 thrips per leaf when the watermelon price was low, medium, and high, respectively. The three sequential sampling plans for F. schultzei generated for the economic injury levels resulted in similar and more rapid decisions compared to the conventional plan, especially when the pest density was high. The three economic injury levels and the sequential sampling plans generated in the present study can be incorporated into integrated pest management programs for watermelon crops because these plans provide a rapid and adequate control decision for F. schultzei.
392

Desenvolvimento e validação de um referencial metodológico para avaliação da cultura de segurança de organizações nucleares / Development and validation of a methodological framework for assessing the safety culture of nuclear organizations

Roberta Grazzielli Ramos Alves Passarelli Momesso 16 August 2017 (has links)
A cultura de segurança na área nuclear é definida como o conjunto de características e atitudes da organização e dos indivíduos que fazem que, com uma prioridade insuperável, as questões relacionadas à proteção e segurança nuclear recebam a atenção assegurada pelo seu significado. Até o momento, não existem instrumentos validados que permitam avaliar a cultura de segurança na área nuclear. Em vista disso, os resultados da definição de estratégias para o seu fortalecimento e o acompanhamento do desempenho das ações de melhorias tornam-se difíceis de serem avaliados. Este trabalho teve como objetivo principal desenvolver e validar um instrumento para a avaliação da cultura de segurança de organizações nucleares, utilizando o Instituto de Pesquisas Energéticas e Nucleares como unidade de pesquisa e coleta de dados. Os indicadores e variáveis latentes do instrumento foram definidos utilizando como referência modelos de avaliação de cultura de segurança da área da saúde e área nuclear. O instrumento de coleta de dados proposto inicialmente foi submetido à avaliação por especialistas da área nuclear e, posteriormente, ao pré-teste com indivíduos que pertenciam à população pesquisada. A validação do modelo foi feita por meio da modelagem por equações estruturais utilizando o método de mínimos quadrados parciais (Partial Least Square - Structural Equation Modeling PLS-SEM), no software SmartPLS. A versão final do instrumento foi composta por quarenta indicadores distribuídos em nove variáveis latentes. O modelo de mensuração apresentou validade convergente, validade discriminante e confiabilidade e, o modelo estrutural apresentou significância estatística, demonstrando que o instrumento cumpriu adequadamente todas as etapas de validação. / The safety culture in the nuclear area is defined as that assembly of characteristics and attitudes in organizations and individuals which establishes that, as an overriding priority, nuclear plant safety and protection issues receive the attention warranted by their significance. Until now, there are no validated instruments to evaluate the safety culture in the nuclear area. This fact makes it difficult to assess the results of strategies for its strengthening and of the improvement actions. The main objective of this work was to develop and validate an instrument for the evaluation of the safety culture of nuclear organizations, using the Instituto de Pesquisas Energéticas e Nucleares as a research unit and data collection. The indicators and latent variables of the instrument were defined using health and nuclear area models of safety culture evaluation as reference. The data collection instrument initially proposed was submitted to the evaluation by nuclear area experts and, subsequently, to the pretest with individuals who belonged to the researched population. The validation of the model was performed through structural equation modeling using the Partial Least Square - Structural Equation Modeling - PLS-SEM method in the SmartPLS software. The final version of the instrument was composed by forty indicators distributed in nine latent variables. The measurement model showed convergent validity, discriminant validity and composite reliability, and the structural model showed statistical significance. Therefore the overall model has successfully accomplished all the validation steps.
393

Otimização e validação de metodologia analítica para determinação de metais e semimetais em efluentes líquidos por espectrometria de emissão óptica com plasma de argônio (ICP-OES) / Optimization and validation of analytical methodology for determination of metals and semimetals in wastewater by inductively coupled plasma optical emission spectrometry (ICP-OES)

Joyce Rodrigues Marques 24 November 2015 (has links)
Além da Resolução CONAMA 430/11 definir limites para o lançamento de efluentes, também define que os laboratórios que realizam análises ambientais devem ser acreditados pelo INMETRO e também devem ter sistema de controle de qualidade implantado. Para o atendimento destes requisitos legais, o presente trabalho visa otimizar, validar e implantar a metodologia analítica desenvolvida e aplicada no Centro de Química e Meio Ambiente (CQMA) do Instituto de Pesquisas Energéticas e Nucleares (IPEN/ CNEN SP) para a quantificação dos elementos cádmio, chumbo, cobre, prata, crômio, zinco, estanho, níquel, ferro, bário, manganês e boro em amostras de efluentes líquidos por Espectrometria de Emissão Óptica com Plasma Acoplado Indutivamente (ICP-OES). Esta metodologia é utilizada para a determinação de metais e semimetais em amostras coletadas no Programa de Monitoramento Ambiental PMA-Q do IPEN. Todo o processo de validação desta dissertação foi baseado no guia Orientativo do INMETRO DOQ-CGCRE-008 - Orientação sobre Validação de Métodos Analíticos. No estudo de seletividade verificou-se que a matriz não interfere nas curvas analíticas do método em estudo; a faixa de trabalho foi determinada com base nos valores máximos permitidos (VMP) pelas legislações ambientais vigentes (Resolução CONAMA 430/11, DE 8.468/76 e DE 15.425/80) e no histórico de dados do PMA-Q e todas as curvas analíticas apresentam comportamento linear na faixa de trabalho abrangida pelo método; os limites de detecção e quantificação do método atendem aos limites definidos pelas legislações ambientais vigentes e à precisão e exatidão necessárias; a precisão e exatidão apresentaram resultados satisfatórios para a finalidade do método analítico; além do método demonstrar-se robusto, embora seja necessário que o analista se atente à variação de alguns fatores no momento da realização das análises. Também foi possível realizar a estimativa de incerteza do método de modo que fosse alcançado nível de confiança de 95% dos resultados, foram levadas em consideração todas as etapas de preparo e análise das amostras e foi possível obter incerteza global entre 4,6% e 12,23%. Através dos resultados obtidos nos testes estatísticos e pela avaliação do analista foi possível verificar que o método desenvolvido e aplicado no CQMA é adequado para o fim pretendido. / Beyond define limits to wastewater release, CONAMA Resolution n° 430/11 also define that laboratories, which perform environmental analysis, have to be accredited by INMETRO and must have quality control system deployed. In order to meet this legal requirements, this work aims to optimize, validate and deploy the analytical methodology developed and applied at the Centre of Environmental Science and Technology (CQMA) at Nuclear and Energy Research Institute (IPEN/ CNEN - SP), to the determination of the elements: cadmium, lead, copper, chromium, zinc, tin, nickel, iron, barium, manganese and boron in wastewater samples by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). This methodology is used to the determination of metals and semimetals in samples collected in the IPENs Environmental Monitoring Program PMA-Q. The entire process of validation in this dissertation relied on INMETRO guide DOQ-CGCRE- 008 Guidance for Validation of Analytical Methods. In the selectivity test it was possible to verify that the matrix cause no interferences in the calibration curves of the studied method; the working range determined was based on the Maximum Allowed Values (VMP) defined by the current environmental legislations (CONAMA Resolution 430/11, State Decree 8.468/76 and State Decree 15.425/80) and in the historical data from PMA-Q and all calibration curves presented linear behavior; the detection and quantification limits of this method also attend to the requirements of the current environmental legislation and to the required precision and accuracy; the precision and accuracy presented suitable results for the methodology objective; additionally, the analytical method presented satisfactory robustness, although the responsible for the test have to have attention to any instabilities in some factors. The measurement uncertainty was estimated as well, in order to obtain results with 95% of confidence, all steps of preparation and analysis of the samples were considered and was possible to reach global uncertainty between 4,6% and 12,23%. Through the results obtained in the statistics tests and the analyst evaluation, was possible to conclude that the analytical methodology developed at CQMA is adequate to the intended purpose.
394

Desenvolvimento e validação de metodologia para determinação de metais em amostras de água por espectrometria de emissão óptica com plasma de argônio (ICP-OES) / Development and validation of methodology for determination of metals in water samples by optical emission with argon plasma spectrometry (ICP-OES)

Mainara Generoso Faustino 05 November 2015 (has links)
Para atender a legislação ambiental do Conselho Nacional do Meio Ambiente (CONAMA), a Resolução CONAMA 357/2005, é necessário desenvolver metodologias que se aplicam na medição analítica de forma correta e para um controle de qualidade é necessário a aplicação da validação de metodologia. Para atender as exigências legais, o presente trabalho desenvolveu uma metodologia para a identificação de 12 elementos metálicos, tais como: Al, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na e Ni em águas, avaliando 14 pontos, sendo eles GU000-01 (23°46\'49.6\"S-46°47\'22\"0W), GU000-02 (23°45\'29.5\"S-46°46\'18.7\"W), GU000-03 (23°44\'52.2\"S-46°46\'13.6\"W), GU106-04 (23°44\'44.6\"S-46°45\'25.8\"W), GU000-05 (23°44\'57.5\"S-46°45\'24.2\"W), GU107-06 (23°45\'01.2\"S-46°43\'61.5\"W), GU108-07 (23°43\'64.7\"S-46°43\'42.3\"W), GU000-08 (23°42\'96.9\"S-46°43\'61.2\"W), GU109-09 (23°43\'04.6\"S-46°43\'34.0\"W), GU105-10 (23°42\'89.9\"S-46°44\'68.7\"W), GU108-11 (23°42\'53.4\"S-46°43\'44.9\"W), GU103-12 (23°41\'88.5\"S-46°44\'67.3\"W), GU102-13 (23°41\'58.0\"S-46°43\'57.3\"W), GU000-14 (23°40\'78.2\"S-46°43\'55.0\"W), distribuídos pela Represa Guarapiranga, situada no Estado de São Paulo, aplicando a metodologia validade, realizada com base no guia do Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO), Orientação sobre Validação de Métodos Analíticos - DOQ-CGCE-008. Foram avaliados os parâmetros: seletividade, faixa de trabalho/linearidade, limites de detecção e quantificação, tendência/recuperação, precisão, robustez e incerteza de medição. Foi utilizado a técnica de espectrometria de Emissão Óptica com Plasma de Argônio (ICP-OES). O teste de seletividade comprovou que a matriz não interfere nas curvas analíticas elaborada; a faixa de trabalho apresentou um comportamento linear, para as amostras com e sem a matriz de interesse, com um coeficiente de correlação (r), entre 0,9965 a 1,0; os limites de detecção e quantificação do método atendem aos valores máximos permitidos pela Resolução CONAMA 357/2005; com os testes de repetitividade e de recuperação o método demonstrou ser preciso e exato, além de robusto. Posteriormente foi estimado uma incerteza de medição do método. A incerteza expandida estimada variou entre 3 e 18% da concentração encontrada. A validação da metodologia permitiu a sua aplicação para a avaliação da distribuição dos 12 elementos, nas águas da represa Guarapiranga. Foram observados valores altos para Ca, Na e K, em todos os pontos de coletas analisados, evidenciando que são os elementos que fazem parte da característica geológica da área. Os elementos Fe e Al obtiveram valores acima da legislação nos pontos da Represa (G000-01, G000-02 e G000-03). Com os testes dos parâmetros para a validação, com os cálculos estatísticos aplicados, foi possível desenvolver e aplicar uma metodologia adequada para o uso pretendido. / To attend the environmental legislation of the National Environmental Council (CONAMA) CONAMAs Resolution 357/2005, it is necessary to develop methodologies that apply the analytical measurement correctly and to a quality control application of the methodology validation is required. To attend legal requirements, this study developed a methodology for identifying 12 metals, such as: Al, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na and Ni in water in 14 points, being them GU000-01 (23°46\'49.6\"S-46°47\'22\"0W), GU000-02 (23°45\'29.5\"S-46°46\'18.7\"W), GU000-03 (23°44\'52.2\"S-46°46\'13.6\"W), GU106-04 (23°44\'44.6\"S-46°45\'25.8\"W), GU000-05 (23°44\'57.5\"S-46°45\'24.2\"W), GU107-06 (23°45\'01.2\"S-46°43\'61.5\"W), GU108-07 (23°43\'64.7\"S-46°43\'42.3\"W), GU000-08 (23°42\'96.9\"S-46°43\'61.2\"W), GU109-09 (23°43\'04.6\"S-46°43\'34.0\"W), GU105-10 (23°42\'89.9\"S-46°44\'68.7\"W), GU108-11 (23°42\'53.4\"S-46°43\'44.9\"W), GU103-12 (23°41\'88.5\"S-46°44\'67.3\"W), GU102-13 (23°41\'58.0\"S-46°43\'57.3\"W), GU000-14 (23°40\'78.2\"S-46°43\'55.0\"W), distributed by Guarapiranga dam, in the State of São Paulo, applying the methodology of validation based on the National Institute of Metrology, Quality and Technology (INMETRO) guide, \"Guidance on Analytical Methods Validation - DOQCGCE- 008\". The parameters analyzed were: selectivity, working range/linearity, limits of detection and quantification, tendency/recovery, accuracy, robustness and measurement uncertainty. Was used the optical emission with argon plasma spectrometry (ICP-OES) technique. The selectivity test proved that the matrix does not interfere with elaborate analytical curves; the elaborate working range obtained demonstrate a linear behavior for samples with and without the matrix of interest, with a coefficient of correlation (r) between 0,9965 and 1,0; limits of detection and quantification of this method meet the maximum values allowed by CONAMA Resolution 357/2005; with repeatability of tests and recovery method proved to be precise and accurate, and robust. It was subsequently estimated uncertainty of measurement method. The estimated expanded uncertainty varied between 3 and 18% of the concentration found. The validation of the methodology allowed the application for the evaluation of the distribution of 12 elements in Guarapiranga dam waters. Were observed high values for Ca, Na and K, at every point analyzed collections, showing, which are, the elements that are part of the geological characteristic of the area. The iron and aluminum elements obtained values above the law in points Dam (G000-01, G000-02 and G000-03). With the parameters for the validation tests, with the statistical calculations applied, it was possible to develop and apply a methodology appropriate for the intended use.
395

Estudo da dissolução in vitro de cloridrato de diltiazem em cápsulas manipuladas

MENDONÇA, Taciane Ferreira 22 February 2010 (has links)
O cloridrato de diltiazem é um bloqueador de canal de cálcio pertencente ao grupo das benzotiazepinas, usado principalmente no tratamento de angina, hipertensão e arritmias supraventriculares, disponibilizado no mercado nacional na forma farmacêutica de comprimido simples e de liberação prolongada, cápsula de liberação imediata e de liberação prolongada e injetáveis. Até o presente momento, não há método oficial descrito em farmacopeia para quantificação do fármaco, em cápsula de liberação imediata. O objetivo deste estudo foi estabelecer as condições do ensaio de dissolução e validar o ensaio e a metodologia analítica para quantificação do cloridrato de diltiazem em cápsula de liberação imediata. A fim de estabelecer as condições de dissolução para o cloridrato de diltiazem 60 mg, em cápsulas, os medicamentos manipulados A, B e C, respectivamente, foram testados utilizando 900 mL de três meios de dissolução (água, HCl 0,1 mol L-1 e tampão fosfato pH 6,8), aparatos USP 1 e 2 e velocidades de agitação de 50, 75 e 100 rpm. Alíquotas de 10 mL das amostras foram retiradas em 5, 10, 15, 30 e 60 minutos de ensaio com reposição do meio de dissolução. As concentrações do fármaco no meio de dissolução foram determinadas tanto por espectrofotometria por UV a 237 nm quanto por cromatografia líquida de alta eficiência, utilizando coluna Hypersil BDS RP-18 (10,0 cm x 4,0 mm) com tamanho de partícula de 3 μm. A fase móvel foi acetonitrila – tampão fosfato pH 6,2 – trietilamina (45:55:0,2, v/v/v) na vazão de 1,0 mL min-1 e detecção UV a 240 nm. O uso de tampão fosfato pH 6,8 como meio de dissolução, pá como aparato a uma velocidade de agitação de 50 rpm e 30 minutos de teste forneceram resultados satisfatórios para a determinação da dissolução de cloridrato de diltiazem em cápsula de liberação imediata. Os métodos analíticos e o ensaio de dissolução foram validados e demonstraram ser estáveis, lineares, seletivos, precisos e exatos. Finalmente, a aplicação do ensaio às amostras A, B e C, respectivamente, mostraram-se condizentes aos parâmetros exigidos pelos órgãos regulatórios. / Diltiazem hydrochloride is a benzothiazepine calcium channel antagonist, mainly used in the treatment of angina, hypertension and supraventricular arrhythmias and is commercially available in tablets, extended release tablets, immediate release capsules, extended release capsules and injectable dosage forms. At the present moment, there is no official methods described in any pharmacopoeia for the quantification of the drug in immediate release capsules. The aim of this study was to establish dissolution conditions and to validate the analytical methods for diltiazem hydrochloride quantification in pharmaceutical immediate release capsules. Different conditions such as dissolution media (water, 0.1 mol L-1 HCl and pH 6.8 potassium phosphate buffer), apparatus (USP apparatus 1 and 2) and rotation speeds (50, 75 and 100 rpm) were evaluated in order to establish dissolution conditions for 60 mg diltiazem hydrochloride in pharmaceutical capsules. 10 mL sample aliquots were withdrawn at 5, 10, 15, 30 and 60 minutes and replaced. The drug concentrations in dissolution media were determined by both UV spectrophotometry at 237 nm and by a HPLC method, using a Hypersil BDS RP-18 (10.0 cm×4.0 mm), 3 μm particle size column. The mobile phase was acetonitrile-potassium phosphate buffer pH = 6.2- triethylamine (45:55:0.2, v/v/v), at a flowrate of 1.0 mL min-1 and UV detection at 240 nm. The use of potassium phosphate buffer pH 6.8 as dissolution medium, paddle as apparatus at the stirring speed of 50 rpm and 30 minutes of test provided satisfactory results for assessment of dissolution diltiazem hydrochloride immediate release capsules. The described analytical methods and dissolution procedures were validated presenting stability, linearity, selectivity, precision and accuracy. Finally, all the methods were used for quality control assays of the products tests A, B and C, which demonstrated to be in accordance to regulatory demands. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
396

Modelagem matemática do atuador pneumático de uma bancada para ensaio de estruturas

Viecelli, Sandra Edinara Baratto 06 August 2014 (has links)
O presente trabalho trata da modelagem matemática de um atuador pneumático responsável pelo acionamento de uma bancada para ensaios de estruturas mecânicas, a qual será utilizada no projeto de título “Concurso de Pórticos” (processo CNPq nº409998/2013-3, Chamada nº 18/2013 MCTI/CNPq/Secretaria de Políticas da Mulher-PR/Petrobras - Meninas e Jovens Fazendo Ciências Exatas, Engenharias e Computação). As contribuições principais deste trabalho são a modelagem e identificação das características não lineares do atrito no atuador utilizado para a aplicação de forças, bem como a sistematização do modelo matemático completo, sua simulação computacional e validação experimental. Os atuadores pneumáticos são utilizados na maioria das instalações industriais e nos campos da automação e da robótica pelas diversas vantagens que o caracterizam. Dentre estas vantagens considera-se uma tecnologia de baixo custo, manutenção fácil, boa relação peso/potência, rapidez de resposta e principalmente uma tecnologia limpa, que não polui o meio ambiente. Porém, para atuadores pneumáticos a modelagem matemática é complexa quando comparada a outros tipos de acionamentos, pois apresentam limitações no controle decorrente das características não lineares inerentes ao sistema. Estas características não lineares resultam da alta compressibilidade do ar e das não linearidades presentes em sistemas pneumáticos, tais como o comportamento não linear da vazão mássica nos orifícios da válvula e sua zona morta, além do atrito nas vedações do cilindro linear. A modelagem matemática é muito importante para entendimento e previsão do comportamento dinâmico de atuadores pneumáticos e pode contribuir para a adequada aplicação e desempenho em sistemas automáticos, principalmente na definição de estratégias de controle. Neste trabalho, desenvolveu-se a formulação de um modelo matemático não linear completo de 5ª ordem que representa o comportamento dinâmico do atuador pneumático. Com o objetivo de comparação com o modelo desenvolvido, apresenta-se também um modelo matemático não linear de 3ª ordem, validados experimentalmente. Por fim, foram realizados testes de controle de força em malha aberta variando-se a pressão de suprimento do sistema. Os resultados obtidos ilustram as características do modelo matemático desenvolvido. / 94 f.
397

Modelagem matemática de um robô gantry com acionamento pneumático

Maraschin, Leonardo Bortolon 13 April 2016 (has links)
Este trabalho apresenta a modelagem matemática e a estratégia de controle de posição de um robô pneumático para fins de aplicações industriais, incluindo-se os resultados de testes experimentais. Tal robô foi desenvolvido no Núcleo de Inovação em Máquinas Automáticas e Servo Sistemas (NIMASS) da Unijuí Câmpus Panambi. Atuadores pneumáticos são sistemas muito atrativos para diversas aplicações, em especial na robótica, porque eles têm a vantagem de baixo custo, leveza, durabilidade e são limpos, também possuem facilidade de manutenção, têm boa relação força/tamanho e flexibilidade de instalação, e além disso o ar comprimido está disponível na maioria das instalações industriais. Entretanto, sistemas de posicionamento pneumático possuem algumas características indesejáveis as quais limitam o uso destes em aplicações que requerem uma resposta precisa. Estas características indesejáveis são causadas pela compressibilidade do ar e pelas não linearidades presentes em sistemas pneumáticos, tais como o comportamento não linear da vazão mássica nos orifícios da válvula e sua zona morta, além do atrito nas vedações do cilindro pneumático. Neste trabalho obtém-se um modelo matemático não linear de 10ª ordem (total) para os dois primeiros graus de liberdade do robô que tem a estrutura cinemática do tipo Gantry. Os parâmetros da zona morta e do atrito foram obtidos experimentalmente e o modelo proposto foi validado em malha aberta para a primeira junta. É implementada uma estratégia de controle clássico com compensação da não linearidade da zona morta em testes experimentais com malha fechada e planejamento da trajetória desejada senoidal e trapezoidal, sem e com a compensação da zona morta, cujos resultados ilustram as características do controlador utilizado e a importância da compensação da zona morta. Este trabalho de pesquisa contribui para o desenvolvimento e o controle de posição de robôs pneumáticos de baixo custo para aplicação industrial. / 131 f.
398

Validação experimental de um sistema para ensaios modais.

André Moreno da Costa Moreira 22 August 2006 (has links)
Esse trabalho apresenta uma validação do sistema de análise modal experimental disponível no Instituto de Aeronáutica e Espaço. A análise modal experimental é uma técnica consagrada para investigação do comportamento dinâmico estrutural, caracterizado pelos parâmetros de freqüência natural, fatores de amortecimento e formas de vibração, associados a cada modo natural da estrutura investigada. Na condução de ensaios modais, sistemas constituídos por cadeias de excitação e de medição são empregados, envolvendo o uso de vibradores, transdutores de força, condicionadores de sinais, filtros, sample-holds, conversores analógico-digitais e uma unidade de aquisição e processamento digital dos sinais. Neste trabalho, cadeias de excitação e de medição são avaliadas e validadas experimentalmente através de dois casos estudados. O primeiro caso adotado foi a análise de uma placa quadrada, em alumínio, de comportamento amplamente conhecido, excitada por meio de um vibrador alimentado com um sinal aleatório, e tendo como sistema de medição de dados um vibrômetro a laser por varredura de imagem. O segundo caso adotado foi o ensaio modal de uma maquete de vigas conceitualmente representativa do Veículo Lançador de Satélites - VLS, levando em consideração três configurações distintas: a primeira configuração, utilizando um único vibrador como fonte de excitação; a segunda configuração adotando uma dupla excitação da maquete cujos vibradores foram posicionados num mesmo plano e, por fim, a última configuração analisada, cuja excitação da maquete utilizou dois vibradores situados em planos ortogonais, o que possibilitou a análise mais detalhada da estrutura, em função da complexidade do comportamento apresentado pelo sistema em estudo.
399

Desenvolvimento e validação de indicadores para avaliação da qualidade do acompanhamento farmacoterapêutico / Development and validation of indicators for quality assessment of medication management

Lima, Tacio de Mendonça 25 October 2018 (has links)
Um dos elementos para melhoria da qualidade dos serviços farmacêuticos clínicos é medir a qualidade do cuidado prestado e os indicadores podem ser usados nesta avaliação. O presente trabalho teve como objetivos identificar estudos sobre indicadores de qualidade para serviços farmacêuticos clínicos e desenvolver e validar um instrumento de indicadores para avaliação dos serviços de acompanhamento farmacoterapêutico prestados para pacientes ambulatoriais. Para tanto, uma busca abrangente da literatura foi conduzida nas bases de dados PubMed/Medline, Scopus, Lilacs e DOAJ por esses estudos. Os instrumentos apresentados pelos estudos foram avaliados em relação à qualidade das propriedades psicométricas. A seguir, foi desenvolvido um instrumento de indicadores-chave de desempenho. O grupo de pesquisa estabeleceu sete indicadores possíveis para avaliação de especialistas da área através de duas rodadas da técnica Delphi para validação de conteúdo. Ainda, farmacêuticos foram convidados a participar por meio de um questionário para validação de construto e confiabilidade do instrumento. A busca bibliográfica identificou 3.276 registros, dos quais 12 estudos completaram os critérios de inclusão. No geral, o maior número de estudos foi baseado em pesquisas para avaliar a satisfação dos pacientes e usou a revisão da literatura combinada com opinião de especialistas para o desenvolvimento do instrumento. Todos os estudos apresentaram algumas propriedades psicométricas do instrumento. A consistência interna e a validade de conteúdo foram os critérios mais relatados dos estudos, e nenhum deles apresentou o critério de estabilidade. Onze (68,8%) especialistas participaram da primeira rodada da técnica Delphi e nove (81,8%) especialistas completaram as 2 rodadas. Um novo indicador foi desenvolvido após a avaliação do painel de especialistas na primeira rodada. No geral, a validade de conteúdo e construto foi alcançada para o instrumento final. Os resultados desta tese apontam que os instrumentos dos estudos identificados na revisão sistemática apresentaram propriedades psicométricas, porém de forma incompleta ou não satisfatória. Ainda, um instrumento com seis indicadores foi desenvolvido e validado para o Serviço de Acompanhamento Farmacoterapêutico prestado para pacientes ambulatoriais. / One of the elements of quality improvement of medication management services is measuring the quality of care and key performance indicators (KPIs) can be used in this assessment. The study is aimed to identify quality indicators instruments in pharmaceutical care services and to develop and validate KPI instrument for medication management services provided for outpatients. For this, comprehensive literature search was performed in databases PubMed/Medline, Scopus, and Lilacs. The psychometric quality of the instruments was determined. In addition, a key performance indicators instrument was developed. A working group established 7 possible KPIs for assessment of the expert panel through an internet based 2-round Delphi approach. An internet questionnaire was developed for pharmacists in order to construct validity and reliability of the instrument. The literature search yielded 3,276 records, of which 12 studies satisfied the inclusion criteria. Overall, the greatest number of studies were based surveys to assess patients\' satisfaction and used literature review combined with expert\'s opinion for the instrument development. All studies presented some psychometrics properties of the instrument. Internal consistency and content validity were the most reported criteria of the studies and none of them presented stability. Eleven (68.8%) experts participated in the Delphi round 1 and nine (81.8%) experts completed the 2 Delphi rounds. A new KPI was develop after expert panel assessment in the first round. Overall, content and construct validity were reached for final instrument. The results of this thesis point out that instrument of the studies identified in the systematic review presented some psychometrics properties, but did not describe them satisfactorily. In addition, a set of six key performance indicators was developed and validated for medication management services provided for outpatients.
400

Adaptação cultural e validação para o Brasil do instrumento Comply with post-exposure management among health care workers para profissionais de enfermagem / Cultural adaptation and validation for Brazil of the instrument Comply with post-exposure management among health care workers for nursing professionals

Jansen, Adriane Corrêa 30 April 2014 (has links)
Os trabalhadores de enfermagem são expostos a riscos biológicos que podem causar-lhes adoecimento e/ou acidente de trabalho. Diante dessa realidade em vários países, e considerando que a adesão de muitos profissionais às condutas pós-exposição a material biológico, potencialmente contaminado, ainda não é satisfatória, buscou-se, na literatura nacional e internacional, instrumentos validados que quantificassem as variáveis psicossociais envolvidas no comportamento em saúde e, em especial, a adesão às condutas pós-exposição ocupacional a material biológico, internacionalmente recomendadas, necessárias à prevenção das infecções advindas dessa exposição ocupacional. Diante da inexistência de instrumentos brasileiros, validados, que abordassem as condutas pós- exposição a material biológico, selecionamos um instrumento chinês, estruturado no referencial da Teoria do Comportamento Planejado, para traduzi-lo e adaptá-lo para uso em nosso país. Assim, este estudo metodológico, quantitativo teve como objetivo traduzir, adaptar culturalmente e validar para Brasil o instrumento Comply with post-exposure management among health care workers, que avalia a intenção de cumprir as condutas pós- exposição ocupacional a material biológico. Trata-se de um instrumento autoaplicável, composto por questões de caracterização e dimensões relacionadas aos constructos da Teoria do Comportamento Planejado, distribuídas em 61 itens com opções de resposta em escala tipo Likert, específicas para cada uma das seis subescalas (Atitude, Normas Subjetivas, Conhecimento, Autoeficácia, Recursos e Intenção). O processo de adaptação seguiu as diretrizes recomendadas pela literatura. O estudo foi aprovado quanto aos aspectos da ética em pesquisa (Protocolo no 041/12). Os dados foram coletados em seis hospitais da cidade de Uberlândia, Minas Gerais, em amostra de 137 profissionais de enfermagem expostos a material biológico, sendo 119 técnicos de enfermagem (86,9%) e 18 enfermeiros (13,1%). Foi verificada a existência dos efeitos floor e ceiling e a fidedignidade foi avaliada pela consistência interna dos itens e pela estabilidade da medida (teste-reteste). A validade de construto foi avaliada por meio da análise multitraço-multimétodo. O valor do nível de significância adotado foi de 0,05. Foram verificados efeitos ceiling nas subescalas Autoeficácia e Intenção. Em relação às propriedades psicométricas, os resultados obtidos foram: consistência interna verificada pelo coeficiente alfa de Cronbach para as subescalas Atitude, Normas Subjetivas, Autoeficácia, Recursos e Intenção, com valores variando entre 0,81 e 0,91, resultados considerados satisfatórios e para a subescala Conhecimento, avaliada pelo coeficiente de Kuder-Richarson (0,37), considerado insatisfatório. A avaliação da estabilidade da medida obteve resultados positivos em relação à significância estatística, com valores do Coeficiente de Correlação Intraclasse, entre as duas medidas, variando de 0,301 a 0,727; a validade de construto convergente e divergente foi confirmada por meio da análise multitraço-multimétodo, com exceção da subescala Atitude, que apresentou valores insatisfatórios. Assim, podemos concluir que a versão adaptada do instrumento \"Adesão às Condutas Pós-Exposição entre Trabalhadores de Saúde\", para a realidade brasileira, apresenta resultados satisfatórios de validade e fidedignidade, excluindo-se a dimensão Atitude. Assim, após a redefinição da referida subescala com os autores do instrumento original, outros estudos devem ser realizados com amostras maiores. Este estudo resultou em novos conhecimentos científicos relevantes à prevenção do adoecimento de trabalhadores, relacionado às infecções veiculadas por material biológico potencialmente contaminado. / Nursing workers are exposed to biological risks that can cause occupational illness and/or accidents. In view of this reality in different countries, and considering that many professionals\' adherence to the conducts post-exposure to potentially contaminated biological material remains unsatisfactory, a search was undertaken in Brazilian and international literature for validated instruments to quantify the psychosocial variables involved in health behavior, and particularly in the adherence to internationally recommended conducts post-occupational exposure to biological material, necessary to prevent the infections originating in this occupational exposure. In view of the lack of Brazilian validated instruments focused on conducts post-exposure to biological material, we selected a Chinese instrument, structured in the framework of the Theory of Planned Behavior, for translation and adaptation to be used in Brazil. Hence, the objective in this methodological, quantitative study was to translate, culturally adapt and validate the instrument Comply with post-exposure management among health care workers for Brazil, which assesses the intention to comply with conducts post-occupational exposure to biological material. This self-applied instrument consists of characterization questions and dimensions related to the constructs of the Theory of Planned Behavior, distributed into 61 items with specific Likert-scale response alternatives for each of the six subscales (Attitude, Subjective Standards, Knowledge, Self-Efficacy, Resources and Intention). The adaptation process followed the guidelines recommended in the literature. The study received ethical clearance (Protocol 041/12). The data were collected at six hospitals in Uberlândia, Minas Gerais, in a sample of 137 nursing professionals exposed to biological material, including 119 nursing technicians (86.9%) and 18 nurses (13.1%). The existence of floor and ceiling effects was verified and the reliability was assessed through the internal consistency of the items and the stability of the measure (test-retest). The construct validity was assessed using the multitrait-multimethod analysis. Significance was set at 0.05. Ceiling effects were verified in the Self-efficacy and Intention subscales. As regards the psychometric properties, the obtained results were: internal consistency verified using Cronbach\'s alpha for the subscales Attitude, Subjective standards, Self-efficacy, Resources and Intention, ranging between 0.81 and 0.91, which are considered satisfactory, and for the Knowledge subscale, assessed using Kuder-Richarson\'s coefficient (0.37), considered unsatisfactory. The stability assessment of the measure found positive results for the statistical significance, with Intraclass Correlation Coefficients between the two measures ranging between 0.301 and 0.727; the convergent and divergent content validity was confirmed through the multitrait-multimethod analysis, except for the Attitude subscale, with unsatisfactory coefficient. Hence, it can be concluded that the adapted version of the instrument \"Adesão às Condutas Pós-Exposição entre Trabalhadores de Saúde\", for application in the Brazilian reality, presents satisfactory validity and reliability results, excluding the Attitude dimension. Hence, after redefining the subscale with the authors of the original instrument, further research is needed using larger samples. This study resulted in new scientific knowledge that is relevant to prevent occupational illness related to infections caused by potentially contaminated biological material.

Page generated in 0.0502 seconds