• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 86
  • Tagged with
  • 86
  • 86
  • 44
  • 43
  • 24
  • 23
  • 17
  • 17
  • 16
  • 13
  • 13
  • 13
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Estimativa  da carga de exposição diária a material particulado em indivíduos expostos a poluição ambiental de origem veicular / Daily exposure load estimate of particulate matter in individuals exposed to environmental vehicular pollution

Izabela Campos Cozza 04 November 2013 (has links)
Introdução: O uso de amostradores individuais de poluentes e a medida da ventilação (Ve) tem sido avaliados para estimar a dose de exposição a poluição. Por ser a Ve uma medida de difícil mensuração em campo, tem-se estimado a Ve a partir da frequência cardíaca (FC) utilizando equações de regressão construídas em teste de esforço cardiopulmonar (TECP). Entretanto, ainda persistem dúvidas quanto à sua aplicabilidade para estimar a Ve em indivíduos com características semelhantes, porem que não realizaram o TECP. O objetivo do estudo foi avaliar modelos para a estimativa da Ve a partir da FC, construído a partir de TECP, e testar sua aplicabilidade com o uso de medidas da FC em campo, em diferentes grupos expostos a poluentes. Métodos: Avaliados 60 homens, não tabagistas, 33 que trabalham em vias públicas (Grupo Via Publica - GVP), 17 que trabalham em um Parque (Grupo Parque - GP) e 10 outros participantes (Grupo teste - GT) para validação dos modelos utilizados. Todos tiveram registros da FC e da concentração de MP2,5, durante 24 horas, e realizaram TECP. Resultados: Foram encontradas grandes variações nas equações de regressão entre os indivíduos, e entre os grupos avaliados, mas o emprego de equações de regressão médias, para estimar a carga de exposição com registro da FC de 24 horas em campo revelou-se adequado para situações de FC média abaixo de 80 bpm. Conclusão: Equações individuais estimam de maneira mais precisa a Ve e a carga inalada de poluentes, mas equações construídas em um grupo de indivíduos podem ser empregadas para estimar a Ve em atividades onde a FC média não é elevada, como ocorre com a maioria das situações habituais de atividades de vida diárias / Background: To evaluate the degree of exposure to air pollutants, ventilation (Ve) measurements and individual pollutant sampler have been used. Given that Ve is difficult to measure in field studies, it has been estimated based on the heart rate (HR) using regression equations that were built with cardiopulmonary exercise test (CPET) results. However, doubt still exists as to its applicability to estimate Ve in groups of individuals who did not perform the CPET. The purpose of this study was to evaluate different models for estimating Ve based on HR, constructed from CPET, and to test the models\' applicability using HR measurements in the field, in different groups exposed to pollutants. Methods: We evaluated 60 men, nonsmokers: 33 public streets workers (Public Street Group - GPS), 17 park workers (Park Group - GP), and 10 other participants (Test Group - GT) for model validation. All subjects underwent HR and PM2.5 concentration recording throughout 24 hours and CPET. Results: We found wide variations in the regression equations between individuals and the assessed groups. Nonetheless, the use of average regression equations to estimate the exposure load within the 24-hour HR monitoring proved to be suitable for situations of average HR, under 80 bpm. Conclusion: Individual equations estimate Ve and pollutant load inhaled more accurately, but equations constructed based on a group of individuals can be used to estimate Ve in activities where the HR remains lower
72

Análise dos diagnósticos de enfermagem padrão respiratório ineficaz e ventilação espontânea prejudicada apresentados por pacientes adultos com oxigenoterapia em UTI / Analysis of nursing diagnosis ineffective breathing pattern and impaired spontaneous ventilation presented by adult patients with oxygen therapy in ICU / Análisis de los diagnósticos de enfermería patrón respiratorio ineficaz y deterioro de la ventilación espontánea presentados por pacientes adultos con oxigenoterapia en unidad de cuidados intensivos

Seganfredo, Deborah Hein January 2016 (has links)
O objetivo deste estudo foi analisar como se manifestam as características definidoras (CD) dos diagnósticos de enfermagem (DE) Padrão Respiratório Ineficaz (PRI) e Ventilação Espontânea Prejudicada (VEP) e as CD identificadas na literatura para o conceito “ventilação” em pacientes adultos hospitalizados em unidade de terapia intensiva com uso de oxigenoterapia. Tratou-se de um estudo de validação clínica diagnóstica realizado com 626 pacientes. Foram utilizadas as técnicas estatísticas de Análise de Correspondências Múltiplas para realizar o diagnóstico diferencial e Análise de Classe Latente para determinar três níveis de gravidade a partir das CD de PRI, VEP e do conceito “ventilação”, relacionando-os com o modo ventilatório empregado: a) pacientes com menor gravidade em uso de oxigenoterapia através de ventilação espontânea (VE); b) pacientes com gravidade intermediária em uso de oxigenoterapia através de ventilação mecânica não invasiva (VMNI) e; c) pacientes com maior gravidade em uso de oxigenoterapia através de ventilação mecânica invasiva (VMI). As CD que apresentaram maiores valores de sensibilidade para a subamostra em VE foram “fadiga”, “alterações no volume corrente”, “pressão inspiratória diminuída” e “pressão expiratória diminuída”. As CD que apresentaram maiores valores de sensibilidade para a subamostra em VMNI foram “alterações na frequência respiratória”, “alterações no volume corrente”, “relação ventilação/perfusão alterada”, “gases sanguíneos arteriais alterados” e “pressão expiratória diminuída”. As CD que apresentaram maiores valores de sensibilidade para a subamostra em VMI foram “cooperação diminuída”, “inquietação aumentada”, “alterações na frequência respiratória”, “gases sanguíneos arteriais alterados” e “hipóxia”. A partir destes achados, sugere-se que o DE VEP seja excluído da NANDA-I e que sejam incorporadas as CD de VEP que constituíram parte do modelo de classe latente com melhor ajuste ao DE PRI. / The objective of this study was to analyze the behavior of the defining characteristics (DC) of Nursing diagnosis (ND) Ineffective Breathing Pattern (IBP) and Impaired Spontaneous Ventilation (ISV) and DC found in the literature for "ventilation" concept in adult patients hospitalized in intensive care unit in oxygen therapy. The study was a diagnostic clinical validation conducted with 626 patientes. Multiple Correspondence Analysis was used to perform a differential diagnosis and Latent Class Analysis was used to determine three severity levels from the DC of PRI, VEP and of the concept “ventilation", relating them to the ventilation mode used: a) patients with minor oxygen therapy through spontaneous ventilation (SV); b) patients with intermediate severity oxygen therapy through noninvasive mechanical ventilation (NIMV) and; c) patients with severe oxygen therapy through invasive mechanical ventilation (IMV). The DC that showed higher sensitivity for the class in SV were "fatigue", "changes in tidal volume", "decreased inspiratory pressure" and "decreased expiratory pressure”. The DC that showed higher sensitivity for the class in NIMV were "changes in respiratory rate", "changes in tidal volume", "altered ventilation/perfusion ratio", "altered arterial blood gases" and "decreased expiratory pressure". The DC that showed higher sensitivity for the class in IMV were “decreased cooperation", "increased restlessness", "changes in respiratory rate", "altered arterial blood gases" and "hypoxia." Finally, it is suggested that the VEP diagnosis be excluded from the NANDA-I and its DC which formed part of the latent class model with best adjustment be incorporate as DC to ND PRI. / Esta investigación tiene como objetivo analizar cómo se manifiestan las características definidoras (CD) de los diagnósticos de enfermería (DE) Patrón Respiratorio Ineficaz (PRI) y Deterioro de la Ventilación Espontánea (DVE) y las CD identificadas en la literatura para el concepto "ventilación" en pacientes adultos hospitalizados en unidad de cuidados intensivos con oxigenoterapia. Fue un estudio de validación clínica de diagnósticos de enfermería. Compusieron la muestra 626 pacientes. Se utilizaron técnicas estadísticas de Análisis de Correspondencias Múltiple para hacer el diagnóstico diferencial y Análisis de Clase Latente para determinar tres niveles de gravedad desde las CD de PRI, DVE y del concepto "ventilación", relacionándolos con el modo de ventilación empleado: a) pacientes con menos gravedad en uso de oxigenoterapia a través de ventilación espontánea (VE); b) pacientes con gravedad intermedia en uso de oxigenoterapia a través de ventilación mecánica no invasiva (VMNI) y, c) pacientes con mayor gravedad en uso de oxigenoterapia a través de ventilación mecánica invasiva (VMI). Las CD que mostraron mayor sensibilidad para la clase en VE fueron “fatiga”, “cambios en el volumen tidal”, “disminución de la presión inspiratoria” y “disminución de la presión espiratoria”. Las CD que mostraron mayor sensibilidad para la clase en VMNI fueron “cambios en la frecuencia respiratoria”, “cambios en el volumen tidal”, “relación ventilación/ perfusion cambiada”, “gases en sangre arterial cambiados” y “disminución de la presión espiratoria”. Las CD que mostraron mayor sensibilidad para la clase en VMI fueron “cooperación disminuida”, “inquietación demasiada”, “cambios en la frecuencia respiratoria”, “gases en sangre arterial cambiados” y “hipoxia”. A partir de estos resultados, se sugiere que el DE DVE se suprimido de la NANDA-I y que las CD del DE DVE que constituían parte del modelo de clase latente con mejor ajuste se incorporan al DE PRI.
73

Determinação da PEEP ideal e avaliação de atelectasia pulmonar com o uso da ultrassonografia durante intraoperatório de cirurgias eletivas / Ideal PEEP and evaluation of pulmonary atelectasia with the use of ultrasonography during intraoperatory of elective surgeries

Bruno Francisco de Freitas Tonelotto 03 December 2018 (has links)
Introdução: A atelectasia intraoperatória ocorre imediatamente após a indução anestésica e pode ser detectada por ultrassom pulmonar (LUS). No entanto, até o momento o LUS não é utilizado para avaliar a hiperdistensão pulmonar. Neste estudo, descreveu-se um método para detectar hiperdistensão pulmonar usando LUS. A tomografia de impedância elétrica (TIE) foi a referência para comparação dos métodos. Métodos: Dezoito (18) pacientes, com 63 ± 6 anos de idade, com pulmões normais, submetidos à cirurgia abdominal inferior. O TIE foi calibrado, realizada a indução anestésica, intubação e ventilação mecânica. Para reverter a atelectasia posterior, realizou-se uma manobra de recrutamento alveolar com o uso de pressão expiratória final positiva (PEEP) 20 cmH20 e pressão aérea do platô 40 cmH2O durante 120 segundos. A titulação PEEP foi então obtida com valores descendentes: 20, 18, 16, 14,12,10, 8, 6 e 4 cmH2O. Os dados de ultrassom e TIE foram coletados em cada nível PEEP e interpretados por dois observadores independentes. O número de linhas H foi contado usando um filtro especial. O teste de correlação de Spearman e a curva ROC foram utilizados para comparar os dados do LUS e TIE. Resultados: O número de linhas H aumentou linearmente com PEEP: de 3 em PEEP 4 cmH2O a 10 em PEEP 20 cmH2O. Cinco linhas H foram o limiar para a detecção de hiperdistensão pulmonar, definida como hiperdistensão na TIE >= 24,5%. A área sob a curva ROC foi 0,947 (IC 95% 0.901-0.976). Conclusão: O LUS intraoperatório detectou hiperdistensão pulmonar em valores descendentes de PEEP. A presença de cinco ou mais linhas H podem ser consideradas como indicando hiperdistensão pulmonar / Purpose: Intraoperative atelectasis occurs immediately after anaesthetic induction and can be detected by lung ultrasound (LUS). However, LUS is considered as unable to assess pulmonary hyperinflation. In this study, we propose a method to detect pulmonary hyperinflation using LUS. Electrical impedance tomography (EIT) was the reference method. Methods: We included 18 patients, 63 ± 6-year old, with normal lungs, undergoing lower abdominal surgery. The following protocol was used: EIT was calibrated, followed by anaesthetic induction, intubation and mechanical ventilation. To reverse posterior atelectasis, a recruitment maneuver - positive end-expiratory pressure (PEEP) 20 cmH20 and plateau airway pressure 40 cmH2O during 120 sec was performed. PEEP titration was then obtained during a descending trial: 20, 18, 16, 14,12,10, 8, 6 and 4 cmH2O. Ultrasound and EIT data were collected at each PEEP level and analyzed by two independent observers. The number of H lines was counted using a special filter. Spearman correlation test and ROC curve were used to compare LUS and EIT data. Results: The number of H lines increased linearly with PEEP: from 3 at PEEP 4 cmH2O to 10 at PEEP 20 cmH2O. Five H lines was the threshold for detecting pulmonary hyperinflation, defined as a mean decrease in maximum EIT compliance >= 24,5 %. The area under the ROC curve was 0.947 (CI 95% 0.901-0.976). Conclusion: Intraoperative transthoracic LUS can detect pulmonary hyperinflation during a PEEP descending trial. Five or more H lines can be considered as indicating pulmonary hyperinflation in normally aerated lung regions
74

Efeitos da adição de polietilenoglicol ao surfactante exógeno no tratamento da síndrome de aspiração de mecônio em coelhos recém-nascidos / Effects of polyethylene glycol added to exogenous surfactant for meconium aspiration syndrome treatment in newborn rabbits

João Cesar Lyra 06 March 2007 (has links)
O mecônio é um potente inativador da função do surfactante pulmonar, porém a reposição de surfactante exógeno para tratamento da síndrome de aspiração de mecônio em recém-nascidos tem efeito limitado e não diminui a mortalidade. Estudos mostram que a adição de polímeros como o polietilenoglicol (PEG) ao surfactante melhora sua atividade \"in vitro\" mantendo baixa tensão superficial. No presente estudo, avaliamos os efeitos da adição de PEG ao surfactante exógeno sobre a mecânica pulmonar e sobre a regularidade da expansão do parênquima pulmonar em coelhos recém-nascidos. Coelhos da raça New-Zealand-White, nascidos de parto cesáreo aos 30 dias de gestação, foram submetidos a traqueostomia e randomizados em 3 grupos de estudo de acordo com o tipo de tratamento administrado no décimo minuto de ventilação: grupo com aspiração de mecônio, sem tratamento com surfactante exógeno (MEC); grupo com aspiração de mecônio e tratamento com surfactante -100 mg/kg (S100); e grupo com aspiração de mecônio e tratamento com surfactante - 100 mg/kg adicionado de PEG -5% / 15 kDa (PEG). Mecônio humano foi administrado via traqueostomia na dose de 6 ml/kg e concentração de 65 mg/ml. Os animais dos três grupos foram submetidos à ventilação mecânica com pressão positiva no final da expiração de 3 cmH2O; freqüência respiratória de 60 incursões por minuto, fração inspiratória de O2 de 1,0 e pico de pressão inspiratória necessário para se manter volume-corrente fixo de 8 ml/kg. Os valores de complacência dinâmica, pressão ventilatória e volume-corrente foram obtidos a cada 5 minutos até o sacrifício com 20 minutos, com auxílio de um transdutor de pressão associado a um pneumotacógrafo, sendo analisados por um \"software\" específico. O surfactante foi produzido pelo Instituto Butantan (São Paulo, Brasil). Após a ventilação, foi realizada a curva pressão-volume e os pulmões foram fixados com formalina a 10%. A análise histológica foi feita calculando o diâmetro alveolar médio (Lm) e o índice de distorção através do desvio padrão do Lm. Análise estatística foi feita pela ANOVA One Way, com nível de significância de 0,05. Após 20 minutos de ventilação, os valores de complacência dinâmica (ml/cm H2O.kg) foram: 0,44±0,05 (MEC*); 0,68±0,12 (S100) e 0,59± 0,05 (PEG) e de pressão ventilatória (cm H2O): 18,40±2,02 (MEC*); 11,84±1,82 (S100) e 13,60±1,39 (PEG). Ambos os grupos tratados apresentaram padrão de expansão do parênquima mais homogêneo em relação aos animais não tratados: índice de distorção de 18,53±4,71 (MEC*); 8,41±2,35 (S100) e 11,73±4,28 (PEG) (*p < 0,05 vs outros grupos). Concluímos que os animais tratados com surfactante mostraram melhora significativa da mecânica pulmonar, com melhora da complacência pulmonar, menores valores de pressão ventilatória necessários para se manter o volume-corrente pré-estabelecido, maior volume pulmonar máximo e maior homogeneidade do padrão de expansão pulmonar, comparados ao grupo sem tratamento. Não houve influência da adição de polietilenoglicol ao surfactante com relação aos parâmetros avaliados. / Meconium is known to be a potent inactivator of pulmonary surfactant, and exogenous surfactant treatment for meconium aspiration syndrome failed to decrease mortality. A number of studies have shown, in vitro, that the addition of polymers such as polyethylene glycol (PEG) to the surfactant maintains good surface activity in the presence of meconium. In the present study we evaluated the effects of the (PEG) addition to the exogenous surfactant in the pulmonary mechanics and in the regularity of pulmonary parenchyma inflation in newborn rabbits. New-Zealeand-White rabbits born by c-section were submitted to tracheotomy and soon after human meconium (6 ml/kg - 65 mg/ml) was administrated through tracheotomy. A randomization was done after 10 minutes ventilation, into 3 study groups according to the surfactant treatment used: MEC (no treatment), S100 (100 mg/kg) and PEG (100 mg/kg added with PEG 5% / 15kDa). The animals were ventilated with 100 % oxygen, respiratory rate of 60 / minute and positive end-expiratory pressure of 3 cm H2O. Peak inspiratory pressure was adjusted to keep a steady tidal volume of 8 ml/kg. A ventilator-plethysmograph system was used and values of dynamic compliance, ventilatory pressure and tidal volume were recorded every 5 minutes, using specific software, within a period of 20 minutes. The surfactant was produced by Butantan Institute (Sao Paulo, Brazil). After the ventilation period, a PV-curve was performed and the lungs were fixed in 10% formalin. Histological analysis was assessed calculating the mean linear intercept (Lm) and lung tissue distortion (SDI) by the standard deviation of the Lm. Statistical analysis was made by ANOVA One Way, significance was set at 0.05. After 20 minutes of ventilation, dynamic compliance (ml/kg.cmH2O) was 0.44±0.05 (MEC*); 0.68±0.12 (S100) and 0.59±0.05 (PEG) and ventilatory pressure (cmH2O) was 18.40±2.02 (MEC*); 11.84±1.82 (S100) and 13.60±1.39 (PEG). Both groups receiving surfactant had lower mean linear intercept and more homogeneity in the lung parenchyma when compared with MEC group: SDI = 18.53±4.71 (MEC*), 8.41±2.35 (S100) and 11.73±4.28 (PEG) (*p < 0,05 vs all the other groups). We concluded that animals treated with surfactant showed significant improvement in pulmonary mechanics and more regularity of the lung parenchyma compared with non-treated animals. This improvement was found in both studied groups (independently of the PEG addition) without differences between them.
75

Dependência de ventilação pulmonar mecânica na assistência pediátrica no Município do Rio de Janeiro

Costa, Maria Tereza Fonseca da January 2011 (has links)
Submitted by Luis Guilherme Macena (guilhermelg2004@gmail.com) on 2013-07-05T17:39:56Z No. of bitstreams: 1 Maria Tereza Fonseca da Costa.pdf: 3605712 bytes, checksum: d115f31efe017f3b85af7f13d23776d3 (MD5) / Made available in DSpace on 2013-07-05T17:39:56Z (GMT). No. of bitstreams: 1 Maria Tereza Fonseca da Costa.pdf: 3605712 bytes, checksum: d115f31efe017f3b85af7f13d23776d3 (MD5) Previous issue date: 2011 / Fundação Oswaldo Cruz. Instituto Fernandes Figueira. Departamento de Ensino. Programa de Pós-Graduação em Saúde da Criança e da Mulher. Rio de Janeiro, RJ, Brasil / Internações hospitalares de crianças e adolescentesportadores de alguma condição crônica de saúde têm evoluído de modo crescente em diferentes países e também apresentam-se como uma situação de saúde que deve ser considerada no planejamento de ações e organização de serviços de saúde, no Brasil. O exemplo das internações por dependência crônica de ventilação pulmonar mecânica é apresentado no presente estudo,a partir da observação inicial de que constituem-se situações que determinam longa permanência hospitalar em leitos de alta complexidade, como nosde terapia intensiva pediátrica, sendo também alvo de solicitações através de sentenças judiciais para cobertura de assistência domiciliar ainda precariamente estabelecida no âmbito do sistema de saúde brasileiro. Há mais de três décadas que têm sido realizados estudos em outros países, na tentativa de ampliar-se o conhecimento sobre este problema de saúde, sendo analisados diferentes aspectos relacionados ao mesmo, como alternativas de locais seguros para cuidados em saúde oferecidos a estes pacientes crônicos e as diferenças de resultados médicos e sociais entre as alternativas possíveis. Com o objetivo de conhecer e analisar a ocupação de leitos de terapiaintensiva pediátrica por pacientes com dependência crônica de ventilação pulmonar mecânica, foi realizado um estudo seccional do tipo levantamento censitário de casos, de janeiro a março de 2011, em 29 hospitais públicos localizados na Cidade do Rio de Janeiro. O estudo permitiu identificar 31 pacientes de 0 a 18 anos, internados e em ventilação mecânica invasiva há 3 meses ou mais, em 10 dos 29 hospitais consultados. Nas unidades de terapia intensiva havia 14 internações justificadas por esse tipo de dependência tecnológica, caracterizando uma ocupação de 21% do total de leitos disponíveis de terapia intensiva, no período de estudo. O conhecimento desse quantitativo permite aprofundamento da discussão sobre aspectos éticos, técnicos e normativos que devem ser considerados no desenvolvimento de propostas à assistência de pacientes crônicos, visando a melhor relação entre investimentos e resultados, para os pacientes, seus familiares e a sociedade. / Children and adolescents with chronic health conditions hospitalizations are increasingly evolved in different countries and presented as a health situation that must be considered in planning and organizing action of health services in Brazil. The hospital chronic dependency on mechanical ventilation is an example presented in this study, from the initial observation situation which determining long stay high complexity hospital beds, as in the pediatric intensive care, is also the subject of requests through sentences legal coverage for home care, still precariously established within Brazilian health system. Studies in others countries to expand knowledge about this health problem had been for over three last decades, analyzing different aspects related as alternative safe places for health care offered tothese chronic patients and differences between medical and social results from possible alternatives. With the aim to understand and analyze the occupation ofpediatric intensive care beds with ventilator-dependent patients, a survey was realized from January to March, 2011, in 29 public hospitals located in the city of Rio de Janeiro. The study identified 31 patients from zero to 18 years,hospitalized and on invasive mechanical ventilation for 3 months or more, in 10 of the 29 investigated hospitals. In 14 stays in intensive care units werejustified for this type of technological dependency, characterizing a 21% rateoccupancy of total intensive care beds available, along the research period. Knowledge that quantitative conduct to in-depth discussion on ethical, technical and legal standards should be considered when developing proposals aimed assistance for chronic patients, seeking the best value between investments and outcomes for patients, their family and society.
76

Análise dos diagnósticos de enfermagem padrão respiratório ineficaz e ventilação espontânea prejudicada apresentados por pacientes adultos com oxigenoterapia em UTI / Analysis of nursing diagnosis ineffective breathing pattern and impaired spontaneous ventilation presented by adult patients with oxygen therapy in ICU / Análisis de los diagnósticos de enfermería patrón respiratorio ineficaz y deterioro de la ventilación espontánea presentados por pacientes adultos con oxigenoterapia en unidad de cuidados intensivos

Seganfredo, Deborah Hein January 2016 (has links)
O objetivo deste estudo foi analisar como se manifestam as características definidoras (CD) dos diagnósticos de enfermagem (DE) Padrão Respiratório Ineficaz (PRI) e Ventilação Espontânea Prejudicada (VEP) e as CD identificadas na literatura para o conceito “ventilação” em pacientes adultos hospitalizados em unidade de terapia intensiva com uso de oxigenoterapia. Tratou-se de um estudo de validação clínica diagnóstica realizado com 626 pacientes. Foram utilizadas as técnicas estatísticas de Análise de Correspondências Múltiplas para realizar o diagnóstico diferencial e Análise de Classe Latente para determinar três níveis de gravidade a partir das CD de PRI, VEP e do conceito “ventilação”, relacionando-os com o modo ventilatório empregado: a) pacientes com menor gravidade em uso de oxigenoterapia através de ventilação espontânea (VE); b) pacientes com gravidade intermediária em uso de oxigenoterapia através de ventilação mecânica não invasiva (VMNI) e; c) pacientes com maior gravidade em uso de oxigenoterapia através de ventilação mecânica invasiva (VMI). As CD que apresentaram maiores valores de sensibilidade para a subamostra em VE foram “fadiga”, “alterações no volume corrente”, “pressão inspiratória diminuída” e “pressão expiratória diminuída”. As CD que apresentaram maiores valores de sensibilidade para a subamostra em VMNI foram “alterações na frequência respiratória”, “alterações no volume corrente”, “relação ventilação/perfusão alterada”, “gases sanguíneos arteriais alterados” e “pressão expiratória diminuída”. As CD que apresentaram maiores valores de sensibilidade para a subamostra em VMI foram “cooperação diminuída”, “inquietação aumentada”, “alterações na frequência respiratória”, “gases sanguíneos arteriais alterados” e “hipóxia”. A partir destes achados, sugere-se que o DE VEP seja excluído da NANDA-I e que sejam incorporadas as CD de VEP que constituíram parte do modelo de classe latente com melhor ajuste ao DE PRI. / The objective of this study was to analyze the behavior of the defining characteristics (DC) of Nursing diagnosis (ND) Ineffective Breathing Pattern (IBP) and Impaired Spontaneous Ventilation (ISV) and DC found in the literature for "ventilation" concept in adult patients hospitalized in intensive care unit in oxygen therapy. The study was a diagnostic clinical validation conducted with 626 patientes. Multiple Correspondence Analysis was used to perform a differential diagnosis and Latent Class Analysis was used to determine three severity levels from the DC of PRI, VEP and of the concept “ventilation", relating them to the ventilation mode used: a) patients with minor oxygen therapy through spontaneous ventilation (SV); b) patients with intermediate severity oxygen therapy through noninvasive mechanical ventilation (NIMV) and; c) patients with severe oxygen therapy through invasive mechanical ventilation (IMV). The DC that showed higher sensitivity for the class in SV were "fatigue", "changes in tidal volume", "decreased inspiratory pressure" and "decreased expiratory pressure”. The DC that showed higher sensitivity for the class in NIMV were "changes in respiratory rate", "changes in tidal volume", "altered ventilation/perfusion ratio", "altered arterial blood gases" and "decreased expiratory pressure". The DC that showed higher sensitivity for the class in IMV were “decreased cooperation", "increased restlessness", "changes in respiratory rate", "altered arterial blood gases" and "hypoxia." Finally, it is suggested that the VEP diagnosis be excluded from the NANDA-I and its DC which formed part of the latent class model with best adjustment be incorporate as DC to ND PRI. / Esta investigación tiene como objetivo analizar cómo se manifiestan las características definidoras (CD) de los diagnósticos de enfermería (DE) Patrón Respiratorio Ineficaz (PRI) y Deterioro de la Ventilación Espontánea (DVE) y las CD identificadas en la literatura para el concepto "ventilación" en pacientes adultos hospitalizados en unidad de cuidados intensivos con oxigenoterapia. Fue un estudio de validación clínica de diagnósticos de enfermería. Compusieron la muestra 626 pacientes. Se utilizaron técnicas estadísticas de Análisis de Correspondencias Múltiple para hacer el diagnóstico diferencial y Análisis de Clase Latente para determinar tres niveles de gravedad desde las CD de PRI, DVE y del concepto "ventilación", relacionándolos con el modo de ventilación empleado: a) pacientes con menos gravedad en uso de oxigenoterapia a través de ventilación espontánea (VE); b) pacientes con gravedad intermedia en uso de oxigenoterapia a través de ventilación mecánica no invasiva (VMNI) y, c) pacientes con mayor gravedad en uso de oxigenoterapia a través de ventilación mecánica invasiva (VMI). Las CD que mostraron mayor sensibilidad para la clase en VE fueron “fatiga”, “cambios en el volumen tidal”, “disminución de la presión inspiratoria” y “disminución de la presión espiratoria”. Las CD que mostraron mayor sensibilidad para la clase en VMNI fueron “cambios en la frecuencia respiratoria”, “cambios en el volumen tidal”, “relación ventilación/ perfusion cambiada”, “gases en sangre arterial cambiados” y “disminución de la presión espiratoria”. Las CD que mostraron mayor sensibilidad para la clase en VMI fueron “cooperación disminuida”, “inquietación demasiada”, “cambios en la frecuencia respiratoria”, “gases en sangre arterial cambiados” y “hipoxia”. A partir de estos resultados, se sugiere que el DE DVE se suprimido de la NANDA-I y que las CD del DE DVE que constituían parte del modelo de clase latente con mejor ajuste se incorporan al DE PRI.
77

Análise dos diagnósticos de enfermagem padrão respiratório ineficaz e ventilação espontânea prejudicada apresentados por pacientes adultos com oxigenoterapia em UTI / Analysis of nursing diagnosis ineffective breathing pattern and impaired spontaneous ventilation presented by adult patients with oxygen therapy in ICU / Análisis de los diagnósticos de enfermería patrón respiratorio ineficaz y deterioro de la ventilación espontánea presentados por pacientes adultos con oxigenoterapia en unidad de cuidados intensivos

Seganfredo, Deborah Hein January 2016 (has links)
O objetivo deste estudo foi analisar como se manifestam as características definidoras (CD) dos diagnósticos de enfermagem (DE) Padrão Respiratório Ineficaz (PRI) e Ventilação Espontânea Prejudicada (VEP) e as CD identificadas na literatura para o conceito “ventilação” em pacientes adultos hospitalizados em unidade de terapia intensiva com uso de oxigenoterapia. Tratou-se de um estudo de validação clínica diagnóstica realizado com 626 pacientes. Foram utilizadas as técnicas estatísticas de Análise de Correspondências Múltiplas para realizar o diagnóstico diferencial e Análise de Classe Latente para determinar três níveis de gravidade a partir das CD de PRI, VEP e do conceito “ventilação”, relacionando-os com o modo ventilatório empregado: a) pacientes com menor gravidade em uso de oxigenoterapia através de ventilação espontânea (VE); b) pacientes com gravidade intermediária em uso de oxigenoterapia através de ventilação mecânica não invasiva (VMNI) e; c) pacientes com maior gravidade em uso de oxigenoterapia através de ventilação mecânica invasiva (VMI). As CD que apresentaram maiores valores de sensibilidade para a subamostra em VE foram “fadiga”, “alterações no volume corrente”, “pressão inspiratória diminuída” e “pressão expiratória diminuída”. As CD que apresentaram maiores valores de sensibilidade para a subamostra em VMNI foram “alterações na frequência respiratória”, “alterações no volume corrente”, “relação ventilação/perfusão alterada”, “gases sanguíneos arteriais alterados” e “pressão expiratória diminuída”. As CD que apresentaram maiores valores de sensibilidade para a subamostra em VMI foram “cooperação diminuída”, “inquietação aumentada”, “alterações na frequência respiratória”, “gases sanguíneos arteriais alterados” e “hipóxia”. A partir destes achados, sugere-se que o DE VEP seja excluído da NANDA-I e que sejam incorporadas as CD de VEP que constituíram parte do modelo de classe latente com melhor ajuste ao DE PRI. / The objective of this study was to analyze the behavior of the defining characteristics (DC) of Nursing diagnosis (ND) Ineffective Breathing Pattern (IBP) and Impaired Spontaneous Ventilation (ISV) and DC found in the literature for "ventilation" concept in adult patients hospitalized in intensive care unit in oxygen therapy. The study was a diagnostic clinical validation conducted with 626 patientes. Multiple Correspondence Analysis was used to perform a differential diagnosis and Latent Class Analysis was used to determine three severity levels from the DC of PRI, VEP and of the concept “ventilation", relating them to the ventilation mode used: a) patients with minor oxygen therapy through spontaneous ventilation (SV); b) patients with intermediate severity oxygen therapy through noninvasive mechanical ventilation (NIMV) and; c) patients with severe oxygen therapy through invasive mechanical ventilation (IMV). The DC that showed higher sensitivity for the class in SV were "fatigue", "changes in tidal volume", "decreased inspiratory pressure" and "decreased expiratory pressure”. The DC that showed higher sensitivity for the class in NIMV were "changes in respiratory rate", "changes in tidal volume", "altered ventilation/perfusion ratio", "altered arterial blood gases" and "decreased expiratory pressure". The DC that showed higher sensitivity for the class in IMV were “decreased cooperation", "increased restlessness", "changes in respiratory rate", "altered arterial blood gases" and "hypoxia." Finally, it is suggested that the VEP diagnosis be excluded from the NANDA-I and its DC which formed part of the latent class model with best adjustment be incorporate as DC to ND PRI. / Esta investigación tiene como objetivo analizar cómo se manifiestan las características definidoras (CD) de los diagnósticos de enfermería (DE) Patrón Respiratorio Ineficaz (PRI) y Deterioro de la Ventilación Espontánea (DVE) y las CD identificadas en la literatura para el concepto "ventilación" en pacientes adultos hospitalizados en unidad de cuidados intensivos con oxigenoterapia. Fue un estudio de validación clínica de diagnósticos de enfermería. Compusieron la muestra 626 pacientes. Se utilizaron técnicas estadísticas de Análisis de Correspondencias Múltiple para hacer el diagnóstico diferencial y Análisis de Clase Latente para determinar tres niveles de gravedad desde las CD de PRI, DVE y del concepto "ventilación", relacionándolos con el modo de ventilación empleado: a) pacientes con menos gravedad en uso de oxigenoterapia a través de ventilación espontánea (VE); b) pacientes con gravedad intermedia en uso de oxigenoterapia a través de ventilación mecánica no invasiva (VMNI) y, c) pacientes con mayor gravedad en uso de oxigenoterapia a través de ventilación mecánica invasiva (VMI). Las CD que mostraron mayor sensibilidad para la clase en VE fueron “fatiga”, “cambios en el volumen tidal”, “disminución de la presión inspiratoria” y “disminución de la presión espiratoria”. Las CD que mostraron mayor sensibilidad para la clase en VMNI fueron “cambios en la frecuencia respiratoria”, “cambios en el volumen tidal”, “relación ventilación/ perfusion cambiada”, “gases en sangre arterial cambiados” y “disminución de la presión espiratoria”. Las CD que mostraron mayor sensibilidad para la clase en VMI fueron “cooperación disminuida”, “inquietación demasiada”, “cambios en la frecuencia respiratoria”, “gases en sangre arterial cambiados” y “hipoxia”. A partir de estos resultados, se sugiere que el DE DVE se suprimido de la NANDA-I y que las CD del DE DVE que constituían parte del modelo de clase latente con mejor ajuste se incorporan al DE PRI.
78

Retenção de conhecimentos e habilidades após treinamento de ressuscitação cardiopulmonar em alunos de uma faculdade de medicina / Medical students\' knowledge and skill retention following cardiopulmonary resuscitation training

Rafael Saad 05 June 2018 (has links)
Introdução: Apesar do desenvolvimento tecnológico, permanece baixa a sobrevida hospitalar das vítimas de parada cardiorrespiratória extra-hospitalar. Há importante dúvida na literatura quanto à retenção de habilidades de ressuscitação cardiopulmonar (RCP) e a periodicidade adequada de treinamento para manutenção dessas habilidades. O presente estudo investigou a retenção, em alunos a partir de treinamento no primeiro semestre de ingresso no curso médico, das habilidades práticas de RCP até 42 meses após o referido treinamento. Métodos: Estudo de corte transversal, realizado com 298 alunos de graduação de uma faculdade de Medicina, treinados com base nas diretrizes de ressuscitação de 2010 da American Heart Association. Foram avaliados 205 alunos sem retreinamento das habilidades, divididos em quatro grupos conforme o tempo decorrido desde o treinamento de ingresso: 73 alunos após 1 mês, 55 após 18 meses, 41 após 30 meses e 36 após 42 meses. A análise da retenção das habilidades foi comparada com 93 alunos que referiram ter realizado retreinamento em RCP. Dezenove habilidades de RCP e nove potenciais erros de técnica na execução das ventilações pulmonares e compressões torácicas foram avaliados por meio de simulação realística e revisados com utilização de filmagem e avaliadores independentes. Resultados: A média de retenção das dezenove habilidades nos alunos sem retreinamento foi: 90% após 1 mês, 74% após 18 meses, 62% após 30 meses e 61% após 42 meses (p < 0,001). Nos alunos que referiram retreinamento, a retenção foi de 74% após 18 meses, 70% após 30 meses e 66% após 42 meses do treinamento inicial. Realizada curva de predição da retenção de habilidades, com estimativa de 80% das habilidades mantidas após 10 meses, 70% após 21 meses e 60% após 42 meses. A profundidade das compressões torácicas foi a habilidade com maior retenção ao longo do tempo (87,8%), sem diferença estatística entre os quatro grupos. Houve aumento da prevalência de compressões realizadas com menos de 5 cm de profundidade quando realizadas em frequência maior que 120 por minuto. A média da frequência de compressões torácicas obtidas nos grupos após 1, 18, 30 e 42 meses foi, respectivamente, 114, 114, 104 e 108 compressões por minuto; 104 (50,7%) alunos mantiveram frequência média entre 100-120 por minuto. As ventilações pulmonares apresentaram diminuição progressiva de retenção, de 93% após 1 mês até 19% após 42 meses (p < 0,001). Todos os alunos efetivaram o choque com o desfibrilador externo automático, porém com o grupo após 1 mês do treinamento com menor tempo para efetivação do choque e maior prevalência de posicionamento adequado das pás do desfibrilador. Conclusões: O presente estudo demonstrou diferentes níveis de retenção para as habilidades de RCP e diferentes níveis de decréscimo de tais habilidades ao longo de 42 meses. A profundidade das compressões torácicas e o uso do desfibrilador externo automático foram as habilidades com maior retenção ao longo do tempo. Treinamentos adicionais ao longo do curso de Medicina atenuaram a perda de habilidades, mas sem retorno ao desempenho observado após 1 mês do treinamento. Sugerimos que o intervalo mínimo de retreinamento para manutenção de pelo menos 70% das habilidades deva ser de 18 a 24 meses / Introduction: Despite technological development, the survival of victims of out-ofhospital cardiac arrest remains low. There are important questions in the literature regarding the retention of cardiopulmonary resuscitation (CPR) skills and the ideal frequency of retraining required to enhance retention of skills. This study investigated the retention of practical CPR skills by medical students over 42 months after training in the first semester of admission to the medical course. Methods: A cross-sectional study was conducted with 298 undergraduate medical students who were trained based on the 2010 American Heart Association resuscitation guidelines. A total of 205 students divided into four groups according to the time elapsed since the entrance training were evaluated without retraining (73 students after 1 month, 55 students after 18 months, 41 students after 30 months and 36 students after 42 months). The analysis of the retention of skills was compared to 93 students who reported having performed retraining in CPR. Nineteen CPR skills and nine potential technical errors in ventilations and chest compressions were evaluated by realistic simulation and reviewed using filming by independent examiners. Results: The mean retention of the nineteen skills in not retrained students was: 90% after 1 month, 74% after 18 months, 62% after 30 months and 61% after 42 months (p < 0.001). In retraining students, retention was 74% after 18 months, 70% after 30 months, and 66% after 42 months of initial training, with statistical difference between the students with and without retraining in the 30-month group (p=0.005). The estimation of mean skill retention was 80% after 10 months, 70% after 21 months and 60% after 42 months. The depth of chest compressions was the skill with greater retention over time (87.8%), with no statistical difference among groups. There was an increase in the prevalence of compressions performed with less than 5 cm depth when performed at a frequency greater than 120 per minute. The mean chest compressions rate obtained in the groups after 1, 18, 30 and 42 months were 114, 114, 104 and 108 per minute, respectively, and 104 (50.7%) students maintained a mean frequency of 100-120 per minute. Pulmonary ventilation showed a progressive decrease in retention from 93% after 1 month to 19% after 42 months (p < 0.001). All students delivered the shock with the automated external defibrillator; however, for the group one month post-training, the time for the application of the shock was lower, and the prevalence of adequate positioning of the defibrillator pads was greater. Conclusion: This study showed different retention levels for CPR skills and different decrease levels of these skills over 42 months. Depth of chest compressions and use of automated external defibrillator were the skills with the highest retention over time. Additional training throughout the medical course attenuated the loss of skills, but no return to the initial performance achieved after 1 month. We suggest that the minimum retraining interval for maintenance of at least 70% of skills should be 18 to 24 months
79

Análise regional da dinâmica ventilatória em transplante pulmonar com tomografia de impedância elétrica / Assessment of regional ventilatory dynamics in lung transplantation, using electrical impedance tomography

José Eduardo Afonso Júnior 23 August 2010 (has links)
INTRODUÇÃO: A monitorização da ventilação em transplante pulmonar depende de medidas estáticas e globais a partir de testes de função pulmonar e tomografia computadorizada, o que não é suficiente para detectar alterações regionais no parênquima pulmonar, que podem ser relevantes na avaliação de diferentes causas de comprometimento funcional. Tomografia de Impedância Elétrica (TIE) é uma técnica não-invasiva e livre de radiação com base na medição do potencial elétrico na superfície da parede torácica. O comportamento dinâmico e as informações quantitativas extraídas de imagens da TIE tornam possível avaliar as diferenças regionais na ventilação pulmonar. OBJETIVOS: Avaliar a ventilação regional com a TIE, em pacientes submetidos a transplante pulmonar unilateral ou bilateral e avaliar as variações ventilatórias em várias posições diferentes. MÉTODOS: A TIE foi realizada em 18 pacientes transplantados de pulmão (7 pacientes com transplante de pulmão bilateral, 6 pacientes com transplante unilateral por enfisema e 5 pacientes com transplante unilateral por fibrose), nas posições: sentada, supina, prona e decúbitos lateral direito e esquerdo. Os pacientes foram orientados a realizar 30 ciclos de ventilação espontânea e, em seguida, uma manobra de capacidade vital lenta. RESULTADOS: A comparação entre os grupos mostrou que houve diferença entre porcentagem de ventilação referente ao melhor pulmão (nos unilaterais o melhor pulmão era o transplantado e nos bilaterais o pulmão com maior ventilação na posição sentada). Na ventilação espontânea os transplantes unilaterais por enfisema e fibrose tinham 79% e 83% da ventilação gerada pelo pulmão transplantado, enquanto para os bilaterais o melhor pulmão contribuía com 57% da ventilação. Houve redução significativa na desproporção da ventilação quando comparada a ventilação espontânea com a capacidade vital (p = 0,001). Na ventilação espontânea houve variação da ventilação de acordo com a posição analisada, o que não aconteceu na capacidade vital. A medida do ângulo de fase foi próxima a zero para os bilaterais, negativa para os unilaterais por enfisema e positiva para os unilaterais por fibrose, mostrando que nos bilaterais havia sincronia entre o esvaziamento dos dois pulmões e nos grupos unilaterais havia dissincronia (diferentes constantes de tempo). CONCLUSÃO: A TIE pode ser uma ferramenta útil para o estudo pacientes transplantados de pulmão, evidenciando diferenças ocultas na dinâmica ventilatória entre os pulmões nativos e os de pulmões transplantados. Como esperado, os pacientes de transplante de pulmão unilateral exibiram uma ventilação muito mais heterogênea regionalmente. O decúbito lateral e a ventilação espontânea amplificam tais diferenças. / INTRODUCTION: Ventilation monitoring in lung transplantation is still depending on static and global measurements from lung function testing and computed tomography, what is not enough to detect regional changes in lung parenchyma, which may be relevant in evaluating different causes of functional impairment. Electrical Impedance Tomography (EIT) is a noninvasive and radiation-free technique based on the measurement of electric potentials at the chest wall surface. The dynamic behavior and the quantitative information extracted from EIT images make it possible to assess regional differences in lung ventilation. OBJECTIVES: To assess regional ventilation with EIT, in patients who underwent single or bilateral lung transplantation and to evaluate ventilatory variations in several different body positions. METHODS: We performed the EIT in 18 lung transplanted patients (7 bilateral lung transplantation patients, 6 single lung transplantation patients with emphysema and 5 single lung transplantation patients with fibrosis), in seated, supine, right, left and ventral positions. Patients were asked to perform 30 cycles of spontaneous ventilation and then a slow vital capacity maneuver. RESULTS: The comparison between groups showed that there was difference between the percentage of ventilation related to the best lung (the best lung in single lung patients was the transplanted lung and in the bilateral patients was the lung with best ventilation in the sitting position). The ventilation generated by the transplanted lung on spontaneous ventilation in single lung patients for emphysema and fibrosis were 79% and 83% respectively, whereas for the bilateral group better lung contributed with 57% of ventilation. Significant reduction in the disparity of ventilation occurred comparing the spontaneous ventilation and the vital capacity maneuver (p = 0.001). Ventilation changed in accordance with the position analyzed in spontaneous ventilation, what did not happen in vital capacity. The measurement of phase angle was close to zero for the bilateral, negative for single lung emphysema group and positive for single lung fibrosis group, showing that we had synchronicity between the emptying of both lungs in the bilateral group and disynchronicity in the single lung groups (different time constants). CONCLUSION: EIT can be a useful tool to study lung transplant patients, evidencing occult differences in lung dynamics between the native and the transplanted lung. As expected, single lung transplant patients exhibited a much more disturbed regional ventilation. The lateral decubitus and the spontaneous ventilation amplified such differences
80

Comparação da assincronia toracoabdominal ao repouso e ao exercício em pacientes com doença pulmonar obstrutiva crônica utilizando diferentes metodologias / Comparison of thoracoabdominal asynchrony at rest and during exercise in chronic obstructive pulmonary disease patients by applying different methodologies

Porras, Desiderio Cano 23 July 2014 (has links)
Pacientes portadores de doença pulmonar obstrutiva crônica (DPOC) podem apresentar assincronia toracoabdominal (ATA). Existem diversos métodos de estimativa da ATA, porém, não há um consenso sobre qual é o mais adequado. O objetivo deste estudo foi comparar dois métodos de estimativa da assincronia toracoabdominal e avaliar a ineficiência ventilatória em pacientes DPOC no repouso e durante o exercício. Foram avaliados 22 pacientes com DPOC (VEF1 40,2±10,5% predito) e 13 indivíduos controle (GC) pareados por idade, gênero e índice de massa corpórea. A cinemática toracoabdominal foi avaliada utilizando pletismografia optoeletrônica no repouso e durante o exercício leve e moderado (70% da carga máxima) no ciclo ergômetro. A ATA foi calculada entre a caixa torácica superior (CTS) e inferior (CTI) e o abdome (ABD) utilizando os métodos de ângulo de fase (AF) e relação de fase (RF). A ineficiência ventilatória foi calculada em cada compartimento como a diferença entre o volume máximo (VM) e o volume calculado (VC) de acordo com o ciclo respiratório (determinado pela soma de volume dos três compartimentos) dividida pelo volume máximo (VM-VC)/VM. Os pacientes com DPOC foram classificados como assíncronos (grupo AT) ou não assíncronos (grupo NA) utilizando como referência os valores do GC. Foi utilizado o teste qui-quadrado ou de Fisher para avaliar a discriminação de pacientes entre os métodos e o ANOVA de dois fatores para comparações entre os grupos. O nível de significância foi ajustado para 5%. O método AF determinou maior número de pacientes com ATA quando comparado com RF no repouso (respectivamente, 15 vs. 7) e no exercício leve (11 vs. 3) e moderado (14 vs. 8). Os valores de assincronia no grupo AT entre CTS-CTI e CTI-ABD foram maiores no repouso (AF: 35,7±45,4° e -42,2±42,5° e RF: 61,8±29,1° e -66,9±27,4°, respectivamente) e no exercício leve (AF: 53,3±35,6° e -55,8±40,4°; RF: 106,1±40,3° e - 124,8±17,2°) e moderado (AF: 61,6±55,1° e -75,9±44,8°; RF: 85,9±23,6° e -81,8±42,2°) quando comparados com os grupos NA (p < 0,05) e GC (p < 0,05). Na análise entre CTSABD não houve diferença entre os grupos. Observou-se que o grupo AT apresentou menor contribuição e maior ineficiência ventilatória da CTI em todos os momentos de avaliação e, durante o exercício moderado, menor volume corrente quando comparado com os grupos NA e GC. Os nossos resultados sugerem que o ângulo de fase apresenta maior detecção de ATA nos pacientes com DPOC. A presença de assincronia parece ocorrer principalmente na caixa torácica inferior e associada com menor contribuição e maior ineficiência ventilatória deste compartimento / Chronic obstructive pulmonary disease (COPD) patients can present thoracoabdominal asynchrony (TAA). There are several TAA estimation techniques, however, there is no consensus about which is the most appropriate. The aim of this study was to compare two thoracoabdominal asynchrony quantification techniques and to assess chest wall ventilatory inefficiency in COPD patients at rest and during exercise. We evaluated 22 COPD patients (FEV1 40,2±10,5% predicted) and 13 healthy controls (CG) matched by age, gender and body mass index. Thoracoabdominal kinematics was assessed via optoelectronic plethysmography at rest and during mild and moderate exercise (70 % maximum workload) in a cycle ergometer. TAA was calculated among upper (URC) and lower ribcage (LRC) and abdomen (ABD) by using the phase angle (PA) and phase relation (PR) approaches. Ventilatory Inefficiency was estimated in each compartment as the difference between the maximal volume (VM) and the volume (VC) calculated according to respiratory timing (sum of volume in the 3 compartments) divided by the maximal volume (VM-VC)/VM. COPD patients were classified as asynchronous (AT group) or not (NA group) by using as reference the values on the controls. Chi-square or Fisher\'s exact test was used for assessing the patients differentiation between the two TAA quantification approaches and two-way ANOVA was used to compare respiratory parameters among groups (CG, AT and NA). Statistical significance was set at 5% level. PA approach determined more patients as asynchronous when compared to RF at rest (respectively, 15 vs. 7) and during mild (11 vs. 3) and moderate (14 vs. 8) exercise. Asynchrony values in AT group among URC-LRC and LRC-ABD were greater at rest (respectively, 35.7±45.4° and -42.2±42.5° with PA and 61.8±29.1° and -66.9±27.4° with PR) and during mild (PA: 53.3±35.6° and -55.8±40.4°; PR: 106.1±40.3° and -124.8±17.2°) and moderate exercise (PA: 61.6±55.1° and - 75.9±44.8°; PR: 85.9±23.6° and -81.8±42.2°) when compared to NA (p < 0.05) and CG (p < 0.05). Analysis among URC-ABD presented no difference between groups. It was observed that AT group presented a smaller LRC contribution and greater ventilatory inefficiency during all assessing moments and, during moderate exercise, had a lower tidal volume when compared to NA and CG. Our results suggest that phase angle approach presents larger TAA detection in COPD patients. This asynchrony seems to occur mainly in the lower ribcage and be associated with decreased contribution and increased ventilatory inefficiency of this compartment

Page generated in 0.084 seconds