• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • Tagged with
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

An study of the vertical dimension and centric relation thesis submitted as a partial fulfillment ... prosthetic dentistry /

Rios, Carlos M. January 1956 (has links)
Thesis (M.S.)--University of Michigan, 1956.
2

A cephalometric analysis of mandibular postural change between rest position and occlusion thesis submitted as partial fulfillment ... orthodontics ... /

Vedder, Robert L. January 1956 (has links)
Thesis (M.S.)--University of Michigan, 1956.
3

Comparação entre o efeito do aumento da dimensão vertical de oclusão e do avanço mandibular na qualidade do sono em pacientes idosos portadores de próteses totais bimaxilares / Comparison between the vertical dimension of occlusion increase and mandibular advance effects on sleep quality in elderly patients wearing maxilar and mandibular complete dentures

Fróes, Thiago Carôso 10 August 2011 (has links)
A população idosa possui alta prevalência de edentulismo e, conseqüentemente, é afetada pelos problemas a ele associados. A perda da dimensão vertical de oclusão (DVO) é um destes problemas que compromete, entre outros fatores, o desempenho do sistema estomatognático. Logo, doenças relacionadas ao colapso da musculatura da via aérea superior (VAS), como a síndrome da apnéia obstrutiva do sono (SAOS), tornam-se enfermidades relevantes para pacientes nesta faixa etária. Sendo assim, medidas terapêuticas eficazes e de baixo custo, como a utilização de aparelhos intraorais (AIOs) para liberação do fluxo aéreo, podem ser empregadas contribuindo para a qualidade do sono destes pacientes. O objetivo deste estudo foi avaliar parâmetros subjetivos e objetivos do sono, em 10 pacientes idosos portadores de Próteses totais (PTs) bimaxilares, após a utilização de novas PTs confeccionadas no Programa Envelhecer Sorrindo e após o uso de dois AIOs: um dispositivo intraoral (DIO), especialmente desenvolvido para aumentar a DVO sem provocar avanço mandibular, e um aparelho de avanço mandibular (AAM). Para isso, questionários de rastreamento da qualidade do sono e polissonografias (PSGs) foram realizados, em quatro momentos distintos: sem as PTs, com as PTs, com o DIO e com o AAM. Foram realizadas, também, telerradiografias em norma lateral (TNL) dos pacientes com as PTs, com o DIO e com o AAM a fim de avaliar alterações no diâmetro da VAS e o posicionamento mandibular nesses três momentos. Concluiu-se que, o AAM testado promove maior porcentagem de sono no estágio 1, podendo contribuir para a melhora na qualidade subjetiva do sono dos pacientes, uma vez que ajudou a diminuir o tempo necessário para iniciar o sono, além de facilitar a manutenção do estado de vigília. / There is a high prevalence of edentulism and problems associated to it in the elderly population. A decrease in vertical dimension of occlusion (VDO) is one of these problems that may compromise the stomatognathic system. Therefore, it is important to investigate diseases related to upper airway (UA) musculature collapse, such as the syndrome of obstructive sleep apnea (OSAS). Therapeutic measures of low cost and high efficacy, such as intraoral appliances (IAs) to release the air flow may be employed, contributing to patients sleep quality. The aim of this study was to evaluate subjective and objective sleep parameters in 10 elderly patients who wore maxilar and mandibular complete dentures (CD). The analyses were performed after the use of a new pair of CD and after using two IAs: an intraoral device (ID), especially developed to increase the VDO without causing mandibular advance, and a mandibular advance device (MAD). For this purpose, questionnaires and polysomnography (PSG) were performed in four distinct stages: patients not wearing CD, wearing CD, wearing ID and wearing MAD. In addition, lateral cephalograms (LC) of patients wearing FD, wearing ID and wearing MAD were performed to assess changes in UAs diameter and in the mandibular positioning. It was concluded that the MAD tested promotes higher percentage of stage 1 sleep and and may contribute to the improvement in patients subjective sleep quality, as it helped to decrease the time needed to fall asleep, and facilitate the maintenance of wakefulness.
4

Comparação entre o efeito do aumento da dimensão vertical de oclusão e do avanço mandibular na qualidade do sono em pacientes idosos portadores de próteses totais bimaxilares / Comparison between the vertical dimension of occlusion increase and mandibular advance effects on sleep quality in elderly patients wearing maxilar and mandibular complete dentures

Thiago Carôso Fróes 10 August 2011 (has links)
A população idosa possui alta prevalência de edentulismo e, conseqüentemente, é afetada pelos problemas a ele associados. A perda da dimensão vertical de oclusão (DVO) é um destes problemas que compromete, entre outros fatores, o desempenho do sistema estomatognático. Logo, doenças relacionadas ao colapso da musculatura da via aérea superior (VAS), como a síndrome da apnéia obstrutiva do sono (SAOS), tornam-se enfermidades relevantes para pacientes nesta faixa etária. Sendo assim, medidas terapêuticas eficazes e de baixo custo, como a utilização de aparelhos intraorais (AIOs) para liberação do fluxo aéreo, podem ser empregadas contribuindo para a qualidade do sono destes pacientes. O objetivo deste estudo foi avaliar parâmetros subjetivos e objetivos do sono, em 10 pacientes idosos portadores de Próteses totais (PTs) bimaxilares, após a utilização de novas PTs confeccionadas no Programa Envelhecer Sorrindo e após o uso de dois AIOs: um dispositivo intraoral (DIO), especialmente desenvolvido para aumentar a DVO sem provocar avanço mandibular, e um aparelho de avanço mandibular (AAM). Para isso, questionários de rastreamento da qualidade do sono e polissonografias (PSGs) foram realizados, em quatro momentos distintos: sem as PTs, com as PTs, com o DIO e com o AAM. Foram realizadas, também, telerradiografias em norma lateral (TNL) dos pacientes com as PTs, com o DIO e com o AAM a fim de avaliar alterações no diâmetro da VAS e o posicionamento mandibular nesses três momentos. Concluiu-se que, o AAM testado promove maior porcentagem de sono no estágio 1, podendo contribuir para a melhora na qualidade subjetiva do sono dos pacientes, uma vez que ajudou a diminuir o tempo necessário para iniciar o sono, além de facilitar a manutenção do estado de vigília. / There is a high prevalence of edentulism and problems associated to it in the elderly population. A decrease in vertical dimension of occlusion (VDO) is one of these problems that may compromise the stomatognathic system. Therefore, it is important to investigate diseases related to upper airway (UA) musculature collapse, such as the syndrome of obstructive sleep apnea (OSAS). Therapeutic measures of low cost and high efficacy, such as intraoral appliances (IAs) to release the air flow may be employed, contributing to patients sleep quality. The aim of this study was to evaluate subjective and objective sleep parameters in 10 elderly patients who wore maxilar and mandibular complete dentures (CD). The analyses were performed after the use of a new pair of CD and after using two IAs: an intraoral device (ID), especially developed to increase the VDO without causing mandibular advance, and a mandibular advance device (MAD). For this purpose, questionnaires and polysomnography (PSG) were performed in four distinct stages: patients not wearing CD, wearing CD, wearing ID and wearing MAD. In addition, lateral cephalograms (LC) of patients wearing FD, wearing ID and wearing MAD were performed to assess changes in UAs diameter and in the mandibular positioning. It was concluded that the MAD tested promotes higher percentage of stage 1 sleep and and may contribute to the improvement in patients subjective sleep quality, as it helped to decrease the time needed to fall asleep, and facilitate the maintenance of wakefulness.

Page generated in 0.1502 seconds