• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Comportement mécanique sous sollicitations alternées de voiles béton armé renforcés par matériaux composites

Qazi, Samiullah 17 January 2013 (has links) (PDF)
Les enquêtes récentes sur les séismes ont fait ressortir l'importance des murs en béton armé en tant que partie intégrante des structures. L'évolution des règlements prend en compte ces considérations, par contre le bâti existant doit subir des renforcements dans l'objectif de leur mise en conformité. Dans cette thèse une étude expérimentale faite sur douze murs (six élancés et six courts) renforcés par un collage externe en composite a été conduite. Les murs ont été conçus en étant sous-renforcés à la flexion et cisaillement. Quatre de ces six échantillons ont été renforcés par des bandes de PRFC collées. Deux spécimens, un témoin et un renforcé, ont été soumis à un test de chargement statique et quatre échantillons, l'un témoin et trois rénovés, ont été soumis à des essais de charge cyclique. La discussion et l'analyse des tests incluent la description de la fissuration, l'analyse de la rigidité, de la capacité de charge ultime, de la ductilité.
2

Analyse systématique du concept de comportement linéaire équivalent en ingénierie sismique / Systematic analysis of the concept of equivalent linear behavior in sismic ingenierie

Nguyen, Thuong Anh 20 December 2017 (has links)
En ingénierie sismique, il est admis que le comportement d’une structure soumise à de forts séismes soit caractérisé par des boucles d’hystérésis qui peuvent être amples ou étroites selon le type de structure impactée. La prise en compte de ce type de comportement non-linéaire dans un calcul temporel présente des difficultés liées à l’identification des paramètres, au coût numérique élevé, au risque de non-convergence. Dans ce contexte, la méthode de linéarisation équivalente, a été introduite en géotechnique dès les années 70. Elle reste peu utilisée dans le domaine des structures malgré les efforts de nombreux auteurs. Ce travail de thèse a pour objet l’étude du comportement linéaire équivalent dans le contexte des méthodes simplifiées d'évaluation de la réponse non-linéaire d'une structure en ingénierie sismique. Nous passons en revue les critères de linéarisation adoptés par les différentes méthodes qui recherchent l’équivalence (1) du déplacement maximum ou (2) de la quantité d’énergie dissipée ou (3) de la force de rappel. Nos analyses montrent que ces trois critères ne sont pas pertinents et/ou efficaces, conduisant à des méthodes peu robustes qui conduisent dans certains cas à des résultats inexplicables. Nous montrons le rôle important, négligé par toutes les méthodes disponibles, du contenu fréquentiel respectif des signaux et du système dans la détermination de la ductilité appelée. Sur cette constatation, nous introduisons une nouvelle méthode de linéarisation équivalente basée sur la fonction de transfert. Nous utilisons cette méthode pour explorer un plan d’expérience numérique dans lequel nous calculons les caractéristiques de fréquence et d’amortissement équivalents en fonction de la ductilité appelée pour différente configurations caractérisées par (a) le rapport entre fréquence de l’oscillateur et fréquence centrale du signal excitateur, (b) la pente d’écrouissage et (c) le modèle de comportement qui varie continument de élastoplastique à endommageant. Nous proposons deux nouvelles approches du comportement linéaire équivalent. La première, visant à améliorer la procédure statique non-linéaire de l’ATC40, utilise la rigidité sécante et le déplacement maximal. Elle fait intervenir une estimation de l’amortissement différente de celle de l’ATC40. Sa pertinence est établie par le fait qu’elle permet d’évaluer avec exactitude le déplacement maximal de systèmes canoniques non-linéaires. La seconde consiste à restituer la dynamique de la réponse d'un oscillateur non-linéaire au travers de la fonction de transfert. Sa pertinence est démontrée au travers des critères d’Anderson, avec notamment un critère relatif au spectre transféré. La détermination du comportement linéaire équivalent par fonction de transfert est validée sur des structures réelles au travers des essais sur voiles en béton armé (SAFE) et sur systèmes des tuyauteries (BARC et EPRI) / In earthquake engineering, it is common that the behaviour of a structure undergoing a strong motion is characterized by wise or narrow hysteresis loops depending on the type of behaviour of the structure. Considering this non-linear behaviour in a transient calculation requires a huge need of resources in terms of calculation time and memory. In this context, the method of equivalent linearization, consisting in the evaluation of the non-linear response of the structure has been introduced by geotechnical engineers In the 1970s. Despite efforts of many authors, this method is still not used in structural field. The goal of this research is to examine the linear equivalent behaviour in the context of the simplified method of evaluating the non-linear response of a structure in earthquake engineering. We review the criteria of equivalence adopted by many methods searching for the equivalence of (1) the maximum of displacement or (2) quantity of dissipated energy or (3) the restore force. Our argumentative analyses carry out that these three criteria are not pertinent and/or efficient. This leads, in some cases, to some unexplained results. We show the important role, which is mostly neglected in existing method, of frequency content while evaluating the ductile demand. Based on this recognition, we introduce a new method of equivalent linearization based on the transfer function. We use this method in order to explore a numerical experimental plan in which we calculate the equivalent characteristics (frequency and damping) versus the ductile demand for different configuration characterized by (a) the ratio between the frequency of the oscillator and the central frequency of the input signal, (b) the hardening and (c) the behaviour which covers the elastoplastic and damaged ones. We propose two new approaches of the linear equivalent behaviour. The first one, aiming to improve the non-linear static procedure of ATC40, use the secant stiffness and the maximal displacement. This approach consists in an estimation of damping which is different to ATC40. Its pertinence is established by evaluating with accuracy the maximal displacement of the canonical non-linear systems. The second approach consists in restitution of the dynamic of the response of a non-linear oscillator by using the transfer function. The pertinence of this proposition is shown through the criteria of Anderson, especially in terms of transferred motion. In this effect, the linear equivalent behaviour based on the transfer function allows to cope the transferred motion through the non-linear oscillator without performing the non-linear transient calculation. The validation of the linear equivalent behaviour based on the transfer function has been examined on real structures through some experimental tests such as the reinforced concrete wall (SAFE) or piping systems (BARC and EPRI)
3

Comportement mécanique sous sollicitations alternées de voiles béton armé renforcés par matériaux composites / Mechanical behavior of RC walls under seismic activity strenghtened with CFRP

Qazi, Samiullah 17 January 2013 (has links)
Les enquêtes récentes sur les séismes ont fait ressortir l'importance des murs en béton armé en tant que partie intégrante des structures. L’évolution des règlements prend en compte ces considérations, par contre le bâti existant doit subir des renforcements dans l’objectif de leur mise en conformité. Dans cette thèse une étude expérimentale faite sur douze murs (six élancés et six courts) renforcés par un collage externe en composite a été conduite. Les murs ont été conçus en étant sous-renforcés à la flexion et cisaillement. Quatre de ces six échantillons ont été renforcés par des bandes de PRFC collées. Deux spécimens, un témoin et un renforcé, ont été soumis à un test de chargement statique et quatre échantillons, l'un témoin et trois rénovés, ont été soumis à des essais de charge cyclique. La discussion et l’analyse des tests incluent la description de la fissuration, l’analyse de la rigidité, de la capacité de charge ultime, de la ductilité. / Recent earthquake surveys have revealed the significance of RC walls as an integral part of structures. It reduces the structure damage to some extent. However, like other structural member they too are vulnerable. Researchers on basis of their post eartthquake survey and laboratary experiments have concluded that the RC wall buildings sustained damage, mainly due to design and construction work flaws. In this thesis experimental result of shear walls is discussed. They were designed under-reinforced to fail in shear in ase of short wall and in flexure for slender walls. Three out of these six specimens, in each case, were strengthened externally with CFRP strips bonded to wall panel and mesh anchors installed at wall foundation joint. Two specimens, one RC and one CFRP retrofitted (short and slender wall each), were subjected to static load test and three specimens, one RC and two to three CFRP retrofitted, were subjected to quasi static cyclic load tests. The test result analysis discussion includes failure mode, stiffness, ultimate load capacity, ductility, and energy dissipation.

Page generated in 0.0955 seconds