Spelling suggestions: "subject:"water - reuse"" "subject:"water - keuse""
441 |
Eficácia do tratamento biológico em gotejadores operando com água residuária doméstica tratada / Effectiveness of biological treatment in drippers operating with domestic wastewater treatedCosta, Danniely de Oliveira 28 August 2014 (has links)
Made available in DSpace on 2016-08-16T13:31:37Z (GMT). No. of bitstreams: 1
DannielyOC_DISSERT.pdf: 2303659 bytes, checksum: 0a8a4e23e67c6b7ec7713ce05f41d2e4 (MD5)
Previous issue date: 2014-08-28 / Water scarcity and environmental degradation in semiarid region are factors that increase the use of treated domestic wastewater aiming its agricultural use. The drip irrigation becomes more sustainable method for this purpose, due to high application efficiency and low risk of contamination of agricultural produce and operators in the field. However, they have a high susceptibility of obstruction the emitters, particularly when operating with wastewaters, because of the biofouling's formation. In this context, the present study seeked to employ biological treatment aimed at the drippers' unblocking that operate with treated domestic wastewater. For that, we assembled an experimental bench in the Experimental Unit for Water Reuse (EUWR), which has a total area of 793.13 m2, installed on the Zoo and Botanical Park located at the Universidade Federal Rural do Semi-Árido (UFERSA), Mossoró campus. To assessment of hydraulic performance and clogging of three types of drippers applying wastewater treated for 400 h, was mounted an experiment with four irrigation units, equipped with three types of emitters (G1, G2 and G3), with three replicates (three lateral lines by type of dripper). Every 80 h of operation evaluated the CUC, CUD, Us, CVQ, RQR and Q. After the operation time of 400 h, was held the second experiment, characterized by the use of biological treatment that consisted of catalyst enzymatic brand Byosol Swift, line FA (Aseptic Fosse) and powder concentrate of bacteria MaxBio brand, used together . The experiment was mounted with three factors, being the first factor the three types of emitters, the second factor the three treatments T1 (without application of the product), T2 (first application of the product) and T3 (second application of the product) and the third factor the dosages DOS1 (80 mg L-1), DOS2 (160 mg L-1), DOS3 (240 mg L-1) and DOS4 (320 mg L-1) the product MaxBio in three replicates (three lateral lines by type of dripper in each irrigation unit). The data were submitted to analysis of simple and multiple regression, mean test and parametric Pearson correlations test. The results indicated that the formation of biofouling resulting from the interaction between the physical, chemical and biological agents led to partial and total clogging of emitters and hence reduction in the hydraulic performance of irrigation units which operate with domestic wastewater treated. The dripper G1 was more susceptible to clogging than the drippers G2 and G3. In dripper G1, the dosage of 80 mg L-1 MaxBio showed more positive results, as the recovery of hydraulic performance, this being more expressive effect with the completion of the second application of the product. A dosage of 80 mg L-1 MaxBio also showed the best results in clearing the dripper G3, the first application of the product is required, only / A escassez hídrica e a degradação ambiental no semiárido são fatores que potencializam a utilização de águas residuárias domésticas tratadas visando seu aproveitamento agrícola. A irrigação localizada torna-se o método mais sustentável para este fim, devido à elevada eficiência de aplicação e do baixo risco de contaminação do produto agrícola e de operadores no campo. No entanto, apresentam alta susceptibilidade ao entupimento de emissores, particularmente quando operam com águas residuárias, em função da formação de bioincrustação. Neste contexto, o presente trabalho teve por objetivo empregar o tratamento biológico visando à desobstrução de gotejadores que operam com água residuária doméstica tratada. Para isso, foi montada uma bancada experimental na Unidade Experimental de Reuso de Água (UERA), a qual apresenta uma área total de 793,13 m2, instalada no Parque Zoobotânico da Universidade Federal Rural do Semi-Árido (UFERSA), campus Mossoró. Para avaliação do desempenho hidráulico e do entupimento dos três tipos de gotejadores aplicando água residuária tratada, durante 400 h, montou-se um experimento com quatro unidades de irrigação, dotadas de três tipos de gotejadores (G1, G2 e G3), em três repetições (três linhas laterais por tipo de gotejador). A cada 80 h de funcionamento avaliou-se o CUC, CUD, Us, CVQ, RQR e Q. Decorrido o tempo de operação de 400 h, realizou-se o segundo experimento, caracterizado pelo emprego do tratamento biológico que constou de catalisador enzimático da marca Byosol Swift, linha FA (Fossa Asséptica) e de pó concentrado de bactérias da marca MaxBio, utilizados conjuntamente. O experimento foi montado com três fatores, sendo o primeiro fator os três tipos de gotejadores, o segundo fator os três tratamentos T1 (sem aplicação do produto), T2 (1ª aplicação do produto) e T3 (2ª aplicação do produto) e o terceiro fator as dosagens DOS1 (80 mg L-1), DOS2 (160 mg L-1), DOS3 (240 mg L-1) e DOS4 (320 mg L-1) do produto MaxBio, em três repetições (três linhas laterais por tipo de gotejador em cada unidade de irrigação). Os níveis de desobstrução dos gotejadores pelos produtos biológicos foram avaliados. Os dados foram submetidos às análises de regressão simples e múltipla, teste de média e teste de correlações paramétricas de Pearson. Os resultados indicaram que a formação de bioincrustação resultante da interação entre os agentes físico-químicos e biológicos propiciou o entupimento parcial e total dos gotejadores e, consequentemente, redução no desempenho hidráulico das unidades de irrigação que operaram com água residuária doméstica tratada. O gotejador G1 foi mais suscetível ao entupimento do que os gotejadores G2 e G3. No gotejador G1, a dosagem de 80 mg L-1 de MaxBio apresentou resultados mais positivos, quanto à recuperação do desempenho hidráulico, sendo este efeito mais expressivo com a realização da segunda aplicação do produto. A dosagem de 80 mg L-1 de MaxBio, também, apresentou os melhores resultados na desobstrução do gotejador G3, sendo necessária, apenas, a primeira aplicação do produto
|
442 |
Reúso de efluentes industriais gerados durante a produção de água purificada na Central de Tratamento de Água do Centro Tecnológico de Vacinas de Bio-Manguinhos/FIOCRUZ / Reuse of waste water generated during production of purified water in the Water Treatment Center of the Technological Center of Bio- Manguinhos Vaccine / FIOCRUZAndrade, Bárbara de Azevedo Scangarelli de January 2014 (has links)
Made available in DSpace on 2015-08-19T13:52:54Z (GMT). No. of bitstreams: 2
16.pdf: 932960 bytes, checksum: b1d8e89ad8512d3f98cec245642f5d48 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2014 / Fundação Oswaldo Cruz. Instituto de Tecnologia em Fármacos/Farmanguinhos. Rio de Janeiro, RJ, Brasil. / Um dos maiores problemas ambientais é a preocupação mundial com a manutenção da qualidade da água para o uso humano. O seu uso intensivo nos setores agrícolas e industriais tem reduzido a sua disponibilidade para o uso doméstico. Uma das alternativas para a redução da extração de água e da poluição hídrica é a prática do reúso. Embora o Brasil não possua uma legislação específica que incentive essa prática, algumas indústrias já possuem em sua política interna o reúso e/ou recuperação de água para a redução de seus custos de fornecimento e de descarte de águas residuárias. Este trabalho estudou a viabilidade de reúso direto das águas residuárias industriais provenientes do processo de produção de água purificada por osmose reversa do Centro Tecnológico de Vacinas (CTV) de Bio-Manguinhos/FIOCRUZ. Foi realizado um levantamento do consumo, da qualidade e do custo da água que abastece os diferentes setores do CTV bem como a qualidade e a quantidade dos rejeitos do sistema de osmose reversa (P1), do analisador de COT (P2) e do gerador de ozônio (P3). Embora esse assunto seja importante no âmbito ambiental, econômico e social, poucos artigos científicos foram encontrados nos principais bancos de dados consultados, principalmente nos termos de reúso direto no setor industrial farmacêutico. A produção de água purificada é a atividade que demanda maior quantidade de água seguida pelas torres de resfriamento e pela produção de vapor industrial. A qualidade dos rejeitos da osmose reversa foi superior a água que abastece os sistemas de refrigeração, além disso, o volume descartado equivale ao necessário para atender às necessidades desses sistemas.A redução no consumo estimado com a aplicação deste projeto poderá ser de até17% de toda água consumida pelo CTV correspondendo a uma economia bruta direta em torno de R$ 500.000,00 por ano. / The great environmental problem is a worldwide preoccupation with maintaining the water quality for human use. Its intensive use in the agricultural and industrial sectors has reduced its availability for domestic use. An alternative to reduce of water extraction and pollution is the reuse practice. Although Brazil has no specific legislation that encourages this practice, some industries already have in their internal politics for water reuse and/or recovery t
o reduce their costs of supply and
disposal of wastewater. This work studied the feasibility of direct reuse of industries
wastewater from the water purified production process by reverse osmosis of the Technological Centre Vaccines (TCV) in Bio-Manguinhos/FIOCRUZ. A survey of consumption, quality and cost of water supplied to different sectors of the CTV and
the quality and quantity of the wastewater of Reverse Osmosis System (P1), the TOC
analyzer (P2) and the ozone generator (P3). Although this issue is important in
environmental, economic and social context, few articles were found in the main
banks of data consulted, especially in terms of direct reuse in the pharmaceutical
industry. The production of purified water is the activity that demands more water
followed by cooling towers and the production of industrial steam. The quality of the wastewater from the reverse osmosis was superior to that water that supplies cooling systems, furthermore, the volume discarded equal to that necessary to meet the needs of these systems. The reduction in the estima ted consumption with the application of this project may be up to 17% of all water consumed by CTV corresponding to a direct gross savings of around R$ 500,000.00 per year.
|
443 |
The effectiveness of implementing eco initiatives to recycle water and food waste in selected Cape Town hotelsDe Lange, Ruan January 2012 (has links)
Thesis submitted in fulfillment of the requirements for the degree
Master of Technology: Tourism and Hospitality Management
in the Faculty of Business
at the Cape Peninsula University of Technology, 2012 / The objective of the research study was to investigate how effective an eco initiative to recycle water and food waste would be when implemented in selected Cape Town hotels. Earthworm farms are able to convert organic food waste into usable compost as an alternative to landfills. Harvesting rainwater as a direct method for the reuse of waste water makes it possible to store captured rainwater for future use. This serves as an alternative source of surface water. The study further investigated whether implementing these initiatives would be successful as a future endeavour.
Environmental movements were the instigators of the high demand for recycling initiatives. These movements aimed to address the deteriorating quality of water supplies, as well as growth in landfills. In South Africa, a decrease in the availability and quality of surface water has been coupled with an annual increase of 3.7 % in the demand for water. Landfills furthermore release toxic smoke when burned. Within the Hospitality Industry, travelers are increasingly seeking out environmentally friendly hotels as part of their corporate travel policy. This has occurred as a result of the increased focus on environmental initiatives by the International community. The researcher therefore aimed to provide practical examples of how existing theory regarding these initiatives is applicable to operations within hotels.
The research methodology was determined through analysing the research strategy, the design and the research instruments. The research strategy was based on gathering facts relevant to the theory of the study. A descriptive approach was therefore adopted as the “-what-” question that was asked when measuring data to answer the research questions. The research design utilised a multi-strategy approach whereby both quantitative and qualitative data were gathered. This resulted in questionnaires, interviews and case studies forming part of the research instruments. The researcher found it effective to corroborate the findings from both quantitative and qualitative data: that is, the findings from the questionnaires were enhanced by the findings from the interviews. The case studies were conducted to provide a practical context to the theory. Recommendations have been made according to technological and social developments. Ultimately, this study illustrates the success of eco initiatives aimed at recycling water and food waste produced by selected hotels in Cape Town and a reduction in the waste generated by the hotels.
|
444 |
Estudo comparativo da qualidade da água de chuva coletada em cobertura convencional e em telhado verdeBudel, Marcel Aramis 31 March 2014 (has links)
CAPES / O estudo consiste em uma comparação da qualidade da água da chuva coletada em duas formas distintas de captação: um sistema composto por um telhado inclinado com telhas de concreto, nomeada (casa 1) e o outro composto por uma cobertura plana com telhado verde, ou seja, vegetado, nomeada (casa 2). Tem por objetivo caracterizar os sistemas utilizados nas duas formas de cobertura, analisar a qualidade da água da chuva captada nos dois sistemas e fazer o acompanhamento da qualidade da água armazenada para posterior uso ao longo do estudo com o intuito de verificar a eficiência e comportamento dos sistemas de captação. Objetiva ainda encontrar relações nas variáveis envolvidas e apresentar os resultados de forma a estabelecer uma comparação qualitativa no desempenho das duas coberturas. O estudo foi realizado em duas casas localizadas na região noroeste da cidade de Curitiba, capital do Paraná. Na casa 1, com telhas de concreto, a água da chuva que escoa pelo telhado é primeiramente coletada por uma calha, seguindo por um duto vertical até o nível do solo, no qual se encontra um filtro simples, então a água é encaminhada para uma cisterna, onde é armazenada, para posterior uso na torneira externa para onde a água é bombeada. Já na casa 2, com cobertura plana vegetada, a água da chuva após passar pelo telhado verde é conduzida por dutos verticais até a cisterna de concreto no nível do solo, então uma eletrobomba recalca a água até um reservatório localizado na cobertura, acima do nível do telhado verde, para armazenamento e posterior uso na torneira externa. As amostras coletadas em nove eventos (17/05/2013 a 03/12/2013) foram analisadas quanto à: pH, turbidez, oxigênio dissolvido e temperatura, que foram medidos no próprio local. Demanda química de oxigênio (DQO), amônia, nitrito, nitrato e fosfato foram amostrados e analisados no laboratório de Saneamento da UTFPR, Campus Ecoville. Ainda quanto à presença de coliformes totais e termotolerantes (E. Coli), foram realizados em um laboratório terceirizado. Observou-se que o telhado convencional da casa 1 apresentou maior qualidade no parâmetro turbidez e demanda química de oxigênio (DQO), já o telhado verde diminuiu a acidez natural da água da chuva. As duas coberturas se mostraram eficientes pela concentração de amônia e nitrato, contudo indicaram concentrações elevadas de fosfato. Nos parâmetros microbiológicos os dois telhados não obtiveram qualidade suficiente para atender a NBR 15.527/2007. Desta forma, tomadas as devidas precauções, se recomenda o uso da água proveniente dos telhados, vegetados e convencional, para descargas de bacias sanitárias, irrigação de gramados e plantas ornamentais, lavagem de veículos, limpeza de calçadas e ruas, limpeza de pátios, espelhos d'água e usos industriais, conforme estabelecido na norma. / The study consists of a comparison of the quality of rainwater collected in two distinct ways of catchments: a system composed of a pitched roof with concrete tiles and another consisted of a vegetated flat coverage, as known as green roof. It aims to characterize the systems used in both forms of coverage, to analyze the quality of rainwater captured in the two systems and to monitor the quality of water stored for later use throughout the study in order to verify the efficiency and performance of catchment systems. It also aims to find relations in the involved variables and to present the results in order to establish a qualitative comparison in the performance of two coverages. The study was conducted in two houses located in the northwest region of the city of Curitiba, capital of Paraná. The appointee, house 1, has a pitched roof with concrete tiles, the rainwater that seeps through the roof is first collected by a trough, followed by a vertical duct to the ground level, with a simple filter, then the water is sent into a tank where it is stored for later use in the external faucet where the water is pumped. However, at house 2, with vegetated flat roof, after passing through the green roof the rainwater is driven by vertical ducts to the concrete tank at ground level, then an electric pump represses the water to a reservoir located on the roof, above the green roof ́s level for storage and later use on the external tap. Samples collected in nine events (17/05/2013 to 03/12/2013) were analyzed for pH, turbidity, dissolved oxygen and temperature, they were measured in situ. Chemical oxygen demand (COD), ammonia, nitrite, nitrate and phosphate were sampled and analyzed in the laboratory of Sanitation UTFPR Campus Ecoville. Nevertheless, for the presence of total and fecal coliforms (E. coli), tests were performed on an outsourced laboratory. As for the results obtained, the conventional roof house 1 rainwater had higher quality in turbidity and chemical oxygen demand (COD) parameter, whereas in house 2 the green roof reduced the natural acidity of rainwater. The two covers were effective in the concentration of ammonia and nitrate, though indicated high concentrations of phosphate. Microbiological parameters in neither roofs met the NBR 15.527/2007 quality. Thus, taken due precautions, it is recommend the use of water from roofs, vegetated and conventional, to flush toilets, to irrigate lawns and ornamental plants, to wash vehicles, to clean sidewalks and streets, to clean patios, water mirrors and to industrial uses, as defined in the standards.
|
445 |
Estudo comparativo da qualidade da água de chuva coletada em cobertura convencional e em telhado verdeBudel, Marcel Aramis 31 March 2014 (has links)
CAPES / O estudo consiste em uma comparação da qualidade da água da chuva coletada em duas formas distintas de captação: um sistema composto por um telhado inclinado com telhas de concreto, nomeada (casa 1) e o outro composto por uma cobertura plana com telhado verde, ou seja, vegetado, nomeada (casa 2). Tem por objetivo caracterizar os sistemas utilizados nas duas formas de cobertura, analisar a qualidade da água da chuva captada nos dois sistemas e fazer o acompanhamento da qualidade da água armazenada para posterior uso ao longo do estudo com o intuito de verificar a eficiência e comportamento dos sistemas de captação. Objetiva ainda encontrar relações nas variáveis envolvidas e apresentar os resultados de forma a estabelecer uma comparação qualitativa no desempenho das duas coberturas. O estudo foi realizado em duas casas localizadas na região noroeste da cidade de Curitiba, capital do Paraná. Na casa 1, com telhas de concreto, a água da chuva que escoa pelo telhado é primeiramente coletada por uma calha, seguindo por um duto vertical até o nível do solo, no qual se encontra um filtro simples, então a água é encaminhada para uma cisterna, onde é armazenada, para posterior uso na torneira externa para onde a água é bombeada. Já na casa 2, com cobertura plana vegetada, a água da chuva após passar pelo telhado verde é conduzida por dutos verticais até a cisterna de concreto no nível do solo, então uma eletrobomba recalca a água até um reservatório localizado na cobertura, acima do nível do telhado verde, para armazenamento e posterior uso na torneira externa. As amostras coletadas em nove eventos (17/05/2013 a 03/12/2013) foram analisadas quanto à: pH, turbidez, oxigênio dissolvido e temperatura, que foram medidos no próprio local. Demanda química de oxigênio (DQO), amônia, nitrito, nitrato e fosfato foram amostrados e analisados no laboratório de Saneamento da UTFPR, Campus Ecoville. Ainda quanto à presença de coliformes totais e termotolerantes (E. Coli), foram realizados em um laboratório terceirizado. Observou-se que o telhado convencional da casa 1 apresentou maior qualidade no parâmetro turbidez e demanda química de oxigênio (DQO), já o telhado verde diminuiu a acidez natural da água da chuva. As duas coberturas se mostraram eficientes pela concentração de amônia e nitrato, contudo indicaram concentrações elevadas de fosfato. Nos parâmetros microbiológicos os dois telhados não obtiveram qualidade suficiente para atender a NBR 15.527/2007. Desta forma, tomadas as devidas precauções, se recomenda o uso da água proveniente dos telhados, vegetados e convencional, para descargas de bacias sanitárias, irrigação de gramados e plantas ornamentais, lavagem de veículos, limpeza de calçadas e ruas, limpeza de pátios, espelhos d'água e usos industriais, conforme estabelecido na norma. / The study consists of a comparison of the quality of rainwater collected in two distinct ways of catchments: a system composed of a pitched roof with concrete tiles and another consisted of a vegetated flat coverage, as known as green roof. It aims to characterize the systems used in both forms of coverage, to analyze the quality of rainwater captured in the two systems and to monitor the quality of water stored for later use throughout the study in order to verify the efficiency and performance of catchment systems. It also aims to find relations in the involved variables and to present the results in order to establish a qualitative comparison in the performance of two coverages. The study was conducted in two houses located in the northwest region of the city of Curitiba, capital of Paraná. The appointee, house 1, has a pitched roof with concrete tiles, the rainwater that seeps through the roof is first collected by a trough, followed by a vertical duct to the ground level, with a simple filter, then the water is sent into a tank where it is stored for later use in the external faucet where the water is pumped. However, at house 2, with vegetated flat roof, after passing through the green roof the rainwater is driven by vertical ducts to the concrete tank at ground level, then an electric pump represses the water to a reservoir located on the roof, above the green roof ́s level for storage and later use on the external tap. Samples collected in nine events (17/05/2013 to 03/12/2013) were analyzed for pH, turbidity, dissolved oxygen and temperature, they were measured in situ. Chemical oxygen demand (COD), ammonia, nitrite, nitrate and phosphate were sampled and analyzed in the laboratory of Sanitation UTFPR Campus Ecoville. Nevertheless, for the presence of total and fecal coliforms (E. coli), tests were performed on an outsourced laboratory. As for the results obtained, the conventional roof house 1 rainwater had higher quality in turbidity and chemical oxygen demand (COD) parameter, whereas in house 2 the green roof reduced the natural acidity of rainwater. The two covers were effective in the concentration of ammonia and nitrate, though indicated high concentrations of phosphate. Microbiological parameters in neither roofs met the NBR 15.527/2007 quality. Thus, taken due precautions, it is recommend the use of water from roofs, vegetated and conventional, to flush toilets, to irrigate lawns and ornamental plants, to wash vehicles, to clean sidewalks and streets, to clean patios, water mirrors and to industrial uses, as defined in the standards.
|
446 |
Controle sanit?rio e ambiental de um projeto de re?so em um complexo de pr?dios corporativosSantos, Jobson Luiz Prazeres dos 22 February 2011 (has links)
Made available in DSpace on 2014-12-17T15:03:26Z (GMT). No. of bitstreams: 1
JobsonLPS_DISSERT.pdf: 2767919 bytes, checksum: e1bb0574f00691c579728b1cd1f3c247 (MD5)
Previous issue date: 2011-02-22 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / The study that resulted in this dissertation was developed at OU RNCE
PETROBRAS, in Natal, which implemented a project of rational use and reuse of
water, including use of wastewater from a Sewage Treatment Plant (STP) already in
place, diluted with water from own wells for irrigation of green area of the building
complex corporate enterprise. Establish a methodology that can serve as guidelines
for future projects controlled reuse of water like this was the objective of this
research. Been proposed, implemented and evaluated three instruments of sanitary
and environmental control: 1) adaptation of sewage treatment plant and quality
control of the treated effluent 2) analysis of soil-nutrient interaction in the irrigated
area, 3) knowledge of the local hydrogeology, especially with regard to the direction
of flow of the aquifer and location of collection wells of Companhia de ?guas e
Esgotos do Rio Grande do Norte (CAERN) situated in the surroundings. These
instruments have proven sufficient and appropriate to ensure the levels of sanitary
and environmental control proposed and studied, which were: a) control of water
quality off the STP and the output of the irrigation reservoir, b) control of water quality
sub surface soil and assessment of progress on soil composition, c) assessment of
water quality in the aquifer. For this, we must: 1) establishing the monitoring plan of
the STP and its effluent quality sampling points and defining the parameters of
analysis, improve the functioning of that identifying the adequacy of flow and
screening as the main factors of operational control, and increase the efficiency of
the station to a relatively low cost, using additional filters, 2) propose, implement and
adapt simple collectors to assess the quality of water percolating into the soil of the
irrigated area, 3) determine the direction of groundwater flow in the area study and
select the wells for monitoring of the aquifer. / A pesquisa da qual resultou esta disserta??o desenvolveu-se na UO RNCE da
PETROBRAS, em Natal, que implantou um projeto de uso racional e re?so de
?guas, com aproveitamento do efluente de uma Esta??o de Tratamento de Esgotos
(ETE) j? existente no local, dilu?do com ?gua de po?os, para irriga??o da ?rea verde
do complexo de pr?dios corporativo da empresa. Estabelecer uma metodologia que
possa servir de orienta??o para futuros projetos de re?so controlado de ?guas
semelhantes a esse foi o objetivo desta pesquisa. Foram propostos, implementados
e avaliados tr?s instrumentos de controle sanit?rio e ambiental: 1) adequa??o da
esta??o de tratamento de esgotos e controle da qualidade do efluente tratado; 2)
an?lise da intera??o nutrientes-solo na ?rea irrigada; 3) conhecimento da
hidrogeologia local, principalmente no que diz respeito ? dire??o do fluxo do
aqu?fero, e localiza??o dos po?os de capta??o da Companhia de ?guas e Esgotos
do Rio Grande do Norte (CAERN) situados no entorno. Estes instrumentos
mostraram-se suficientes e adequados para assegurar os n?veis de controle sanit?rio
e ambiental propostos e estudados, que foram: a) controle da qualidade da ?gua na
sa?da da ETE e na sa?da do reservat?rio de irriga??o; b) controle da qualidade da
?gua no solo sub superficialmente e avalia??o da evolu??o da composi??o do solo;
c) avalia??o da qualidade da ?gua no aq??fero. Para isso, foi necess?rio: 1)
estabelecer o plano de monitoramento da ETE e da qualidade do seu efluente
definindo pontos de amostragem e par?metros de analise, melhorar o funcionamento
da mesma identificando a adequa??o da vaz?o e do peneiramento como principais
fatores do controle operacional, e aumentar a efici?ncia da esta??o a um custo
relativamente baixo, com uso de filtros adicionais; 2) propor, implantar e adequar
coletores simples para avaliar a qualidade da ?gua percolada no solo da ?rea
irrigada; 3) determinar a dire??o do fluxo subterr?neo na ?rea de estudo e selecionar
os po?os para monitoramento da ?gua do aq??fero.
|
447 |
Recarga gerenciada do aqüífero do Aeroporto Internacional Governador André Franco Montoro, Guarulhos/SP: estudo piloto do sistema solo-aqüífero. / Managed aquifer recharge of the Governor André Franco Montoro International Airport, Guarulhos/SP: pilot study of soil-aquifer system.Walter Onyebuchi Okpala 15 February 2011 (has links)
O Aeroporto Internacional Governador André Franco Montoro (GRU), São Paulo, depende inteiramente da água subterrânea para suprir sua demanda. Entretanto, a prática de extração excessiva, que aumenta continuamente para atender à demanda de um número cada vez maior de passageiros e às dificuldades envolvidas com a recarga natural do aqüífero, levou a Empresa Brasileira de Infraestrutura Aeroportuária (Infraero) a procurar outras fontes de abastecimento. Embora a busca de solução para o problema da escassez da água, passe pela opção de recarga gerenciada do aqüífero, a falta da experiência nacional nessa área restringe a tomada da decisão na adoção dessa prática no país. Objetivando contribuir com estudos de viabilidade técnica da recarga gerenciada de aqüíferos em geral e, em particular, do Aeroporto Internacional Governador André Franco Montoro, este trabalho tem o objetivo de verificar, em escala piloto, a capacidade do solo-aqüífero do aeroporto em tratar adequadamente o esgoto gerado localmente. Para atingir esse objetivo, uma área adequada foi selecionada entre as diversas avaliadas, para a construção de uma unidade piloto de recarga de aqüífero. No local selecionado, amostras indeformadas da camada não saturada foram coletadas, caracterizadas e, posteriormente, montadas em colunas experimentais especiais, pelas quais o esgoto foi infiltrado de maneira controlada. Como os resultados desta primeira fase experimental não foram adequadamente atendidos, foi decidido efetuar coletas de amostras indeformadas em uma segunda área do aeroporto, que indicou a existência de uma camada vadosa mais profunda, mas perfil de solo semelhante ao perfil anterior. Os ensaios de colunas foram efetuados com amostras de ambas as áreas, indicando que o solo superficial do aeroporto deverá ser eliminado, ou substituído por uma camada de areia grossa para permitir uma recarga gerenciada que permita a produção de águas com qualidade adequada para os usos preconizados. Os diferentes cenários utilizados nesta pesquisa envolveram a infiltração nas colunas de recarga com esgotos secundários produzidos no aeroporto, após passagem por duas lagoas de retenção, a infiltração do mesmo efluente tratado por um processo físico-químico de coagulação/floculação/sedimentação e pelo mesmo efluente das lagoas de retenção após tratamento por um sistema de membranas de ultrafiltração. Os resultados obtidos são considerados como resultados parciais, uma vez que toda a profundidade do aqüífero não foi utilizada e pelo fato de que, face às restrições acadêmicas vigentes o tempo disponível para a realização da pesquisa foi extremamente restringido. Entretanto, considera-se este trabalho como pioneiro, pelo fato dele se constituir na primeira pesquisa sobre recarga gerenciada no Brasil e, ainda, por fornecer subsídios teóricos e práticos para suportar outros estudos semelhantes que se farão necessários para compreender e promover a prática de recarga gerenciada de aqüíferos no Brasil. / The Governor André Franco Montoro International Airport, São Paulo, entirely depends on groundwater to meet its demand. However, excessive extraction practice which increase continuously in order to attend the demand of increasing number of passengers and the difficulty involved with natural recharge of its aquifer led the Federal Airport Administration Agency (Infraero) to search for other sources of water supply. Although the search for solution for water scarcity problem goes through managed aquifer recharge, lack of national experience in this area restricts decision making in adopting this practice in the country. Contributing to the technical feasibility studies of managed aquifer recharge in general and the Governor André Franco Montoro International Airport in particular, this research has the objective of verifying at the pilot scale level, the capacity of airport soil-aquifer in adequately treating wastewater generated locally. In order to reach this objective, an adequate location was selected within the alternatives evaluated for the construction of a pilot unit for aquifer recharge. Undeformed samples were collected from the unsaturated layer of the selected place, characterized and afterwards, recharged through special experimental columns with wastewater which was filtered in a controlled form. As the results of the first experimental phase were not adequately met, a decision was made to collect undeformed samples from a second location in the airport. The collection indicated the existence of deep unsaturated layer with the soil profile being similar to the profile of the soil layer from which the first samples were collected. The soil column tests were carried out with samples from both areas, indicating that superficial part of airport soil will be eliminated or substituted with a coarse sandy layer in order to permit a managed aquifer recharge which allows production of water that meets the quality of its required uses. Of the different scenarios verified in this research was infiltration of secondary wastewater produced at the airport through soil columns. Another was infiltration of wastewater after its pre-treatment by physicalchemical processes of coagulation/flocculation/sedimentation and still a third scenario, through pre-treatment of secondary effluent by ultrafiltration membrane. The results obtained are considered partial since the total aquifer depth was not used and the fact that academic restrictions limited excessively the time period of the research. However, considering this as a pioneer work, and the fact that it constitutes the first research about managed aquifer recharge in Brazil, and with it, bringing theoretical and practical contributions to support other similar studies which would be necessary in understanding and promoting managed aquifer recharge practice in Brazil.
|
448 |
Estudo de degradação fotoquímica para reúso de águas de processo em complexo industrial petroquímico. / Study of photochemical degradation to reuse of process water at petrochemical industry.Daniella Cristina Barbosa de Lira 06 December 2006 (has links)
A racionalização dos recursos hídricos tem sido uma das metas das indústrias em vários setores. Tais metas exigem inovações tecnológicas tanto para novos processos produtivos quanto para novas técnicas de tratamento e reutilização de água na cadeia de produção. Os custos elevados de água industrial no Brasil, particularmente nas regiões metropolitanas, têm estimulado as indústrias nacionais a avaliar as possibilidades de reúso. O objetivo deste trabalho é a aplicação do tratamento de águas de processo contendo polipropileno utilizando radiação ultravioleta e peróxido de hidrogênio, isto é, o sistema UV/H2O2, visando adequá-las para reúso no próprio processo, reduzindo a necessidade de captação de água pré-tratada e de descarte de efluente. A primeira parte do estudo consistiu na realização de experimentos em um sistema fotoquímico de batelada, empregando quatro diferentes correntes efluentes de processo, para a avaliação da viabilidade técnico-econômica do tratamento fotoquímico, bem como para a obtenção de dados referentes à cinética das reações fotoquímicas. Com base nas informações obtidas, na segunda parte do estudo foram realizados experimentos em um sistema fotoquímico contínuo, a fim de obter dados para o aumento de escala para aplicação industrial do processo de tratamento contínuo. Os resultados experimentais indicaram a viabilidade técnica de aplicação do sistema UV/H2O2 utilizando fonte de luz artificial para todas as correntes de processo estudadas, tendo sido alcançados níveis de remoção de matéria orgânica acima de 90%. No entanto, sob o ponto de vista econômico, apenas as correntes com baixo teor de carbono orgânico total dissolvido (COT), entre 6 e 12 mgC L-1, mostraram-se adequadas ao reúso, após o tratamento. / Rationalization of water use has been one of the goals in many industrial activities, and, in particular, in the petrochemical industry. Such goals demand technological innovations in the productive processes and in techniques for treatment and reuse of water in the production chain. The high costs of industrial water, particularly in some metropolitan regions, have stimulated the industries to evaluate the possibilities of water reuse. The objective of this work is to evaluate the feasibility of the UV/H2O2 photochemical process applied to the treatment of process waste water containing polypropylene, aiming at the reuse of the waste water in the as process water in the industrial complex, thus reducing the need for tap water supply and waste water generation rate. The first part of this study consisted of laboratory-scale experiments in a batch photochemical reactor with four different waste water streams to perform the technical and economical feasibility of the photochemical treatment, as well to obtain data on the degradation rate. Based on the results of the first part, the second part of this study consisted of experiments in a continuous photochemical reactor, aimed at obtaining experimental data for reactor scale-up. Experimental results indicate that the UV/H2O2 photodegradation process is able to remove more than 90% of the organic compounds contained in the waste water. However, only waste waters containing relatively low contaminant levels (between 6 and 12 mgC L-1) can be treated at economically favourable costs.
|
449 |
Quality indices of the final effluents of two sub-urban-based wastewater treatment plants in Amathole District Municipality in the Eastern Cape Province of South AfricaGcilitshana, Onele January 2014 (has links)
Worldwide, water reuse is promoted as an alternative for water scarcity, however, wastewater effluents have been reported as possible contaminants to surface water. The failure of some wastewater treatment processes to completely remove organic matter and some pathogenic microorganisms allows them to initiate infections. This manifests more in communities where surface water is used directly for drinking. To assess water quality, bacteria alone cannot be used as it may be absent in virus-contaminated water. This study was carried out to assess the quality of two wastewater treatment plant effluents from the Eastern Cape Province of South Africa. Physicochemical parameters and microbiological parameters like faecal coliforms, adenovirus, rotavirus, hepatitis A virus, norovirus and enterovirus were evaluated over a projected period of one year. Physicochemical parameters were measured on site using multiparameters, faecal coliforms enumerated using culture-based methods and viruses are detected using both conventional and real-time PCR. Physicochemical parameters like electrical conductivity, turbidity, free chlorine and phosphates were incompliant with the standards set by the Department of Water affairs for effluents to be discharged. Faecal coliform counts were nil for one plant (WWTP-R) where they correlated inversely (P < 0.01) with the high free chlorine. For WWTP-K, faecal coliforms were detected in 27% of samples in the range of 9.9 × 101 to 6.4× 104 CFU/100ml. From the five viruses assessed, three viruses were detected with Rotavirus being the most abundant (0-2034176 genome copies/L) followed by Adenovirus (0–275 genome copies/L) then Hepatitis A virus (0–71 genome copies/L) in the WWTP-K while none of the viruses was detected in WWTP-R. Species B, species C and Adv41 serotypes were detected from the May 2013 and June 2013 samples where almost all parameters were incompliant in the plant. The detection of these viruses in supposedly treated effluents is suggestive of these being the sources of contamination to surface water and therefore renders surface waters unsafe for direct use and to aquatic life. Although real-time PCR is more sensitive and reliable in detection of viruses, use of cell-culture techniques in this study would have been more efficient in confirming the infectivity of the viruses detected, hence the recommendation of these techniques in future projects of this nature.
|
450 |
Hierarquização de ações pré avaliatórias para o gerenciamento dos sistemas de abastecimento de água / Hierarchy of pre evaluative actions for the management of water supply systemsManca, Ricardo da Silva, 1977- 22 January 2015 (has links)
Orientadores: José Gilberto Dalfré Filho, Antonio Carlos Zuffo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-27T05:15:29Z (GMT). No. of bitstreams: 1
Manca_RicardodaSilva_D.pdf: 9827173 bytes, checksum: 450008bf7cf24543fd46e355c0e9e892 (MD5)
Previous issue date: 2015 / Resumo: A discussão acerca do gerenciamento dos recursos hídricos torna-se mais complexa e importante à medida que ocorre a integração entre todas as medidas cabíveis, tanto na oferta quanto na demanda, que permitem o uso eficiente da água. No entanto, ainda há um longo caminho a percorrer para assegurar a distribuição eficiente e equitativa da água. Se os planos voltados à distribuição de água buscavam somente novas captações, atualmente, precisam incorporar novas ferramentas de gestão, tais como a redução das perdas de água, o reúso, o racionamento, a bonificação e tarifação, as campanhas de incentivo à redução do consumo. Mesmo que todas as alternativas do gerenciamento da demanda sejam importantes, é preciso que se definam quais as ações que realmente podem ser valoradas e mensuradas de acordo com a responsabilidade do gestor do sistema, ou seja, há uma enorme dificuldade em se ponderar opções que poderiam contribuir com o aumento da disponibilidade de água de uma região, mas que dependem de fatores externos não controláveis, como fatores climáticos e conscientização da sociedade. Nesse sentido, o objetivo desta pesquisa foi identificar e hierarquizar as principais ações de atuação na demanda hídrica que podem contribuir para o aumento da disponibilidade de água da Região Metropolitana de São Paulo. Fazendo uso do método de tomada de decisão Delphi e das metodologias multicriteriais AHP, CP e CGT, a avaliação dos resultados mostra que medidas como o reúso e a redução de perdas são aliados importantes e que podem contribuir para a diminuição da escassez hídrica nesta região. Dessa forma, conhecendo-se as duas principais medidas prioritárias para a Região Metropolitana de São Paulo, o trabalho propõe a criação do Gerenciamento Integrado da Demanda de Água Prioritário (GIDAP), que avalia todas as medidas no estudo da demanda, porém, com valoração maior para o reúso e a redução de perdas de água / Abstract: The discussion about the management of water resources becomes more complex and important as the integration occurs between all appropriate measures, both supply and demand, which allow the efficient use of water. However, there is still a long way to go to ensure the efficient and equitable distribution of water. If the trend of the traditional planning of water distribution is only the search for new funding nowadays it is necessary to incorporate new management tools, such as the reduction of water losses, reuse, rationing, the subsidy and pricing, incentive campaigns to reduction of consumption. Even if all the demand management alternatives are important, it is necessary to define what actions can actually be valued and measured in accordance with the system manager's responsibility, ie, there is a huge difficulty in considering options that could contribute to the increased availability of water in a region, but that depend on uncontrollable external factors such as climatic factors and awareness of society. In this sense, the objective of this research was to identify and prioritize the key working actions in water demand that may contribute to the increased availability of water in the Metropolitan Region of São Paulo. Making use of the decision-making method Delphi and multicriteria methodologies AHP, CP and CGT, the evaluation of the results shows that measures such as the reuse and waste reduction are important allies and that can contribute to the reduction of water scarcity in the region. Thus, knowing the two main priorities for the Metropolitan Region of São Paulo, the paper proposes the creation of the Integrated Management of Water Demand Priority (GIDAP), which assesses all the measures on the demand study, however, with valuation highest to reuse and reduction of water losses / Doutorado / Recursos Hidricos, Energeticos e Ambientais / Doutor em Engenharia Civil
|
Page generated in 0.0836 seconds