• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação comportamental de juntas soldadas de um aço estrutural do tipo SAC 50 sob fadiga.

Silva, José Geraldo Araújo January 2001 (has links)
Programa de Pós Graduação em Engenharia Civil. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto. / Submitted by giuliana silveira (giulianagphoto@gmail.com) on 2016-01-27T17:57:29Z No. of bitstreams: 1 DISSERTAÇÃO_AvaliaçãoComportamentalJuntas.pdf: 2736305 bytes, checksum: 846af5e9022cfd295e10b918bfddfd38 (MD5) / Approved for entry into archive by Oliveira Flávia (flavia@sisbin.ufop.br) on 2016-01-27T18:48:27Z (GMT) No. of bitstreams: 1 DISSERTAÇÃO_AvaliaçãoComportamentalJuntas.pdf: 2736305 bytes, checksum: 846af5e9022cfd295e10b918bfddfd38 (MD5) / Made available in DSpace on 2016-01-28T12:38:41Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO_AvaliaçãoComportamentalJuntas.pdf: 2736305 bytes, checksum: 846af5e9022cfd295e10b918bfddfd38 (MD5) Previous issue date: 2001 / Este trabalho apresenta o estudo do comportamento de juntas soldadas de um aço estrutural, do tipo SAC 50, sob fadiga. O material foi soldado através do emprego do processo ao arco elétrico com eletrodo revestido. Além dos ensaios mecânicos tradicionais, aplicou-se metodologias da Mecânica de Fratura, através de ensaios de tenacidade à fratura (COD e Integral J), e ensaios de propagação de trincas por fadiga. Avaliou-se as características comportamentais das três regiões do material: zona fundida, zona termicamente afetada e metal base. Verificou-se, em termos de tenacidade, que as três regiões do material, pelo efeito da soldagem, apresentaram comportamento semelhante. Correlacionou-se os valores obtidos nos ensaios de tenacidade com ensaios de impacto Charpy. A zona fundida apresentou valor de COD, δm, maior que a zona termicamente afetada e o metal base, o que significa maior resistência à propagação de trincas. O efeito do fator R não influenciou significativamente o posicionamento das curvas de propagação de trinca por fadiga na região II. No entanto, para R = 0,7, o valor limiar (threshold), ΔKth, sofreu uma alteração significativa, diminuindo para o caso do metal base. Pôde-se verificar, também, que para o ensaio de propagação de trinca por fadiga, o valor limiar, para o metal base foi inferior às outras regiões do CP, caracterizando um pior desempenho. A partir do ensaio de Integral J pôde-se estimar um valor de JQ para o metal base. E ainda, fez-se análises microfractográficas dos CPs ensaiados. Verificou-se o aspecto dúctil das fraturas do material, através de “dimples”. No entanto, para ensaios de impacto Charpy, em ‘baixas” temperaturas, o material apresentou o aspecto frágil das fraturas através da presença de facetas de clivagem. ______________________________________________________________________________________________ / ABSTRACT : This work studied the behavior of welded joints of structural steel type “SAC 50” under fatigue. The material was welded using the process of electric arc with coated electrodes. Besides using the traditional mechanical tests, methods of fractures mechanics were applied through tests of fracture resistance (COD and J integral) and of the fatigue crack propagation. The behavioral features of three areas of interest (cast zone, heat affected zone and base metal) were determined. In terms of strength, the conclusions were that the three areas presented similar behavior considering the welding effect. The values obtained from resistance tests were later related to those from Charpy impact tests. The cast zone presented a higher COD value than the base metal i.e. higher fracture toughness. The effect of the R factor did not present a strong influence in the position of the fatigue crack propagation curves caused by fatigue. However, for R = 0.7, the threshold value (ΔKth), was slightly altered, being reduced in the case of the base metal. For the fatigue crack propagation test, the threshold value for the base metal was lower than that in the another areas of the specimens, indicating a worse performance. Considering the J integral test, it is possible to estimate a JQ value for the base metal. Also, microfractography analyses of specimen were made. The ductile aspect of the material fractures was revealed by the existence of dimples, although, for the Charpy impact test performed under low temperature, the brittle aspect was revealed by.
2

Desenvolvimento e avaliação de revestimentos nanocompósitos de Ni-Co/SiC eletrodepositados sobre aço carbono

PEREIRA, Roseana Florentino da Costa 27 July 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-08-28T22:32:40Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Roseana Florentino Pereira.pdf: 5029115 bytes, checksum: 567d2593b0716a916a10f59de192c44d (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-09-06T22:58:01Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Roseana Florentino Pereira.pdf: 5029115 bytes, checksum: 567d2593b0716a916a10f59de192c44d (MD5) / Made available in DSpace on 2018-09-06T22:58:01Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Roseana Florentino Pereira.pdf: 5029115 bytes, checksum: 567d2593b0716a916a10f59de192c44d (MD5) Previous issue date: 2017-07-27 / No presente trabalho, revestimentos nanocompósitos de Ni-Co/SiC foram desenvolvidos por codeposição de nanopartículas de SiC em um banho eletrolítico com níquel e cobalto, utilizando o aço API 5L X80 como substrato. A influência da densidade de corrente catódica nas propriedades dos depósitos foi investigada e correlacionada com a eficiência de corrente. A morfologia e composição química da superfície e secção transversal dos revestimentos foi analisada por microscopia eletrônica de varredura acoplada com energia dispersiva de raios-X (MEV-EDS) e relacionadas aos resultados de microdureza Vickers (HV) e difração de raios-X (DRX). A adesividade foi verificada pela indentação Rockwell C. Medidas de potencial de circuito aberto (PCA), curvas de polarização potenciodinâmica (PP) e espectroscopia de impedância eletroquímica (EIE) foram realizadas em solução de NaCl 3,5% para investigar a resistência à corrosão. Os resultados mostraram que os revestimentos obtidos possuem morfologia de grãos ramificados em forma de agulha, com valores de microdureza mais elevados do que a microdureza do aço carbono e estrutura de fase cúbica de face centrada com orientação preferencial do plano (220). Através da análise da secção transversal dos depósitos, verificou-se que os mesmos eram formados por camadas intermediárias com composições e microdurezas distintas, de acordo com a densidade de corrente catódica aplicada. Os revestimentos nanocompósitos de Ni-Co/SiC deslocaram o potencial de corrosão para valores mais nobres e aumentaram a resistência à polarização, que resultou em taxas de corrosão mais baixas quando comparadas ao aço API 5L X80 sem revestimento. O revestimento obtido na condição de 55 mA/cm² obteve as melhores propriedades de resistência à corrosão e o estudo cinético realizado nesta corrente revelou que a formação do revestimento ocorre através da depositação de camadas com caráter autocatalítico. / In the present work, Ni-Co / SiC nanocomposite coatings were developed by codepositioning of SiC nanoparticles in an electrolytic bath with nickel and cobalt using API 5L X80 steel as substrate. The influence of cathodic current density on deposit properties was investigated and correlated with current efficiency. The morphology and chemical composition of the surface and cross-section of the coatings was analyzed by scanning electron microscopy coupled with X-ray dispersive energy (SEM-EDS) and related to the results of Vickers microhardness (HV) and X-ray diffraction (XRD ). The adhesiveness was verified by the Rockwell C indentation. Open circuit potential (PCA) measurements, potentiodynamic polarization curves (PP) and electrochemical impedance spectroscopy (EIS) were performed in a 3.5% NaCl solution to investigate corrosion resistance . The results showed that the coatings obtained have a needle shaped branched grain morphology, with microhardness values higher than the carbon steel microhardness and a cubic face structure with a preferred orientation of the plane 220. Through the cross-sectional analysis of the deposits, it was found that they were formed by intermediary layers with different compositions and microhardness, according to the applied cathodic current density. Ni-Co / SiC nanocomposite coatings shifted corrosion potential to nobler values and increased bias resistance, which resulted in lower corrosion rates when compared to uncoated API 5L X80 steel. The coating obtained under the condition of 55 mA / cm 2 obtained the best corrosion resistance properties and the kinetic study carried out in this chain revealed that the formation of the coating occurs through the deposition of layers with an autocatalytic character.

Page generated in 0.0843 seconds