• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • 1
  • Tagged with
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Tecnologia de fachada: cortina com placas de grês porcelanato. / Technology of porcelain tiles curtain wall.

Amaury Antunes de Siqueira Junior 28 February 2003 (has links)
O trabalho apresenta o estado-da-arte das fachadas-cortina executadas com placas de grês porcelanato, discutindo os principais parâmetros para a elaboração de projetos e produção desta tipologia de revestimentos. Acredita-se ser este um dos primeiros trabalhos acadêmicos elaborados no Brasil sobre o assunto, pretendendo-se contribuir quando da implantação desse sistema no país. Procura-se estabelecer os principais conceitos e definições sobre as fachadas-cortina e fachadas ventiladas, objetivando fundamentar a utilização desses termos que vêm sendo empregados sem precisão pelo meio técnico brasileiro. São abordadas as principais características e propriedades dos componentes, elementos construtivos e dispositivos empregados, como também os principais requisitos a serem considerados quando da elaboração do projeto. São destacadas as vantagens relativas desta tecnologia construtiva quando comparada aos revestimentos tradicionais aderidos, ressaltando-se sua importância como alternativa e potencialidades quando comercializado como um sistema de produção. / This report approaches the state-of-art of the porcelain tiles curtain wall. Both design and installations methods are discussed, including main features and properties of the components, elements and devices necessary. Main requirements considered to the design process are also take into consideration. It is believed that this study is one of the first academic studies developed in Brazil concerning this theme, and it is intended to contribute to the implementation of this system in the country. It aims at establishing the main concepts and the definitions on the curtain walls and ventilated facades. The prime objective is to base the correct use of these terms, since they have been used without accuracy by the Brazilian technicians. main features and properties of the components, elements and devices necessary. Main requirements considered to the design process are also take into consideration. Several advantages concerning this type of cladding are emphasized when compared with traditional coverings, standing out the comportance of the method as an interesting technology alternative.
2

Tecnologia de fachada: cortina com placas de grês porcelanato. / Technology of porcelain tiles curtain wall.

Siqueira Junior, Amaury Antunes de 28 February 2003 (has links)
O trabalho apresenta o estado-da-arte das fachadas-cortina executadas com placas de grês porcelanato, discutindo os principais parâmetros para a elaboração de projetos e produção desta tipologia de revestimentos. Acredita-se ser este um dos primeiros trabalhos acadêmicos elaborados no Brasil sobre o assunto, pretendendo-se contribuir quando da implantação desse sistema no país. Procura-se estabelecer os principais conceitos e definições sobre as fachadas-cortina e fachadas ventiladas, objetivando fundamentar a utilização desses termos que vêm sendo empregados sem precisão pelo meio técnico brasileiro. São abordadas as principais características e propriedades dos componentes, elementos construtivos e dispositivos empregados, como também os principais requisitos a serem considerados quando da elaboração do projeto. São destacadas as vantagens relativas desta tecnologia construtiva quando comparada aos revestimentos tradicionais aderidos, ressaltando-se sua importância como alternativa e potencialidades quando comercializado como um sistema de produção. / This report approaches the state-of-art of the porcelain tiles curtain wall. Both design and installations methods are discussed, including main features and properties of the components, elements and devices necessary. Main requirements considered to the design process are also take into consideration. It is believed that this study is one of the first academic studies developed in Brazil concerning this theme, and it is intended to contribute to the implementation of this system in the country. It aims at establishing the main concepts and the definitions on the curtain walls and ventilated facades. The prime objective is to base the correct use of these terms, since they have been used without accuracy by the Brazilian technicians. main features and properties of the components, elements and devices necessary. Main requirements considered to the design process are also take into consideration. Several advantages concerning this type of cladding are emphasized when compared with traditional coverings, standing out the comportance of the method as an interesting technology alternative.
3

Remoção de matéria orgânica e nitrogênio em reator compartimentado anaeróbio / anóxico e aeróbio tratando esgoto doméstico

MORAIS, Juliana Cardoso de 28 August 2015 (has links)
Submitted by Haroudo Xavier Filho (haroudo.xavierfo@ufpe.br) on 2016-01-08T17:59:09Z No. of bitstreams: 1 Tese doutorado - Juliana Morais 8 jan 16.pdf: 3582789 bytes, checksum: 7e2f32c8ce5f016b636e0075bfc783bd (MD5) / Made available in DSpace on 2016-01-08T17:59:09Z (GMT). No. of bitstreams: 1 Tese doutorado - Juliana Morais 8 jan 16.pdf: 3582789 bytes, checksum: 7e2f32c8ce5f016b636e0075bfc783bd (MD5) Previous issue date: 2015-08-28 / CNPq / Avaliou-se a remoção de matéria orgânica e a conversão da matéria nitrogenada em esgoto doméstico através de um sistema de tratamento composto por dois reatores verticais compartimentados, visando o uso em sistemas descentralizados. Os reatores foram construídos em tubo PVC tipo comercial fofo com diâmetro de 0,40 m, altura útil de 3,10 m e volume total de 390 litros, cada. Cada reator tinha dois compartimentos, o primeiro, anaeróbio/anóxico, foi utilizado para remoção de matéria orgânica e desnitrificação; o segundo, aeróbio, foi preenchido com biomédia comercial no intuito de promover a nitrificação. O efluente nitrificado foi recirculado para o compartimento anaeróbio a fim de promover a desnitrificação, utilizando o próprio esgoto bruto como doador de elétrons. Os reatores compartimentados operaram com tempo de detenção hidráulico de 12, 10 e 8h, sendo aplicado uma taxa de recirculação de 1,5 para o reator compartimentado 1 e de 3,0 para o reator compartimentado 2. O desempenho operacional mais satisfatório foi encontrado na fase operada com tempo de detenção hidráulico de 12 h e taxa de recirculação de 1,5 e 3,0 para o reator 1 e 2, respectivamente. A eficiência média de remoção e matéria orgânica do reator compartimentado 1 foi de 52 ± 15 e 81 ± 7 %, para demanda química de oxigênio (DQO) total e DQO filtrada do efluente, respectivamente e de 60 % para N-NTK; os valores médios para os efluentes foram de 119 ± 47 mg DQO/L, 50 ± 23 mg DQO/L e 15 ± 5 mg N-NTK/L, respectivamente. No reator compartimentado 2, a eficiência média alcançada foi 51 ± 15 e 83 ± 6 % para a DQO total e DQO filtrada do efluente, respectivamente e de 57% para N-NTK; os valores médios efluentes de 132 ± 58 mg DQO/L, 46 ± 24 mg DQO/L e 16 ± 3 mg N-NTK/L, respectivamente. Portanto, não houve grande diferença na remoção simultânea de DQO e nitrogênio entre ambos os reatores com diferentes taxas de recirculação. A análise de confiabilidade indicou níveis de confiabilidade satisfatórios de DQO, sólidos suspensos totais, N-amoniacal e eficiência de remoção de matéria orgânica. A dinâmica da população microbiana revelada por PCR-DGGE (Polymerase Chain Reaction - Denaturing Gradient Gel Electrophoresis), sugere um biofilme estratificado, onde nas camadas mais externas existe a presença de micro-organismos aeróbios heterotróficos responsáveis pela degradação da matéria orgânica, e uma camada mais interna com micro-organismos responsáveis pela nitrificação. O estudo de viabilidade econômica do sistema de tratamento proposto apresentou um custo anual de R$ 70,68/habitante e de R$ 6,70/m³ de esgoto tratado. / It was evaluated the removal of organic matter and the conversion of the nitrogenated matter into domestic sewage through a treatment system consisted of two vertical compartmented reactors, aiming the use in decentralized systems. The reactors were built in Polyvinyl chloride with a diameter, height and total volume of 0.40 m, 3.10 m and 390 liters, each. Each reactor had two compartments, the first, anaerobic/anoxic, aimed the removal of organic matter and denitrification; the second, aerobic, was filled with commercial biomedia in order to promote the nitrification. The nitrified effluent was recirculated to the anaerobic compartment in order to promote the denitrification, without the addiction of electron donor. The compartmented reactors operated with hydraulic retention time of 12, 10 and 8 hours, with a recycle ratio of 1.5 to reactor 1 and 3.0 to reactor 2. The most satisfactory operating results were found for hydraulic retention time HRT of 12 h and recycle ratio of 1.5 to the reactor 1 and 3.0 to the reactor 2. The average efficiencies of organic matter for the reactor 1 were 52 ± 15, 81 ± 7 %, for chemical oxygen demand (COD) total and COD filtered effluent, respectively and 60 % for N-TKN; the average effluent was 119 ± 47 mgCOD/L, 50 ± 23 mgCOD/L and 15 ± 5 mgN-TKN/L, respectively. In reactor 2, the average efficiency was 51 ± 15, 83 ± 6 % for COD total and COF filtered effluent, respectively and 57% for N-TKN; the average effluent was 132 ± 58 mgCOD/L, 46 ± 24 mgCOD/L and 16 ± 3 mgN-TKN/L, respectively. Therefore, there was no great difference in the removal of COD and nitrogen between both reactors with different recycle ratios. The reliability analysis indicated satisfactory reliability levels of COD, TSS, N-ammonia and organic matter removal efficiency. The microbial population dynamics revealed by PCR-DGGE (Polymerase Chain Reaction - Denaturing Gradient Gel Electrophoresis) suggests a stratified biofilm. On the outer layers, it is noticed the presence of aerobic heterotrophic microorganisms responsible for the degradation of organic matter, whilst on the inner layer, the microorganisms responsible for nitrification reside. The economic feasibility study of the proposed treatment system presented an annual cost of R$70,68/inhabitant and R$ 6,70/m³ of treated sewage.
4

Adaptación de un proceso de lodos activados en una planta de celulosa utilizando elementos de crecimiento adherido / Adaptação de um proceso de lodos ativados em uma fábrica de celulose utilizando elementos de crescimento aderido

Mansilla, Jorge Patricio Mesa 23 July 2011 (has links)
Made available in DSpace on 2015-03-26T14:01:10Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1432014 bytes, checksum: 44e1ce5d560cc0a4992a09962885b874 (MD5) Previous issue date: 2011-07-23 / Celulosa Arauco y Constitución S.A., Planta Constitución, possui, desde 2001 de uma Estação de Tratamento de Efluentes (ETE) de lodos ativados cujo decantador secundário foi inabilitado devido ao terremoto de grau 8,8 na escala Richter no ano de 2010. Enquanto está sendo construído um novo sistema de decantação secundária, o sistema tem sido operado abertamente sem esta unidade de separação e recirculação de lodo o que reduz a sua eficiência de tratamento. A queda de eficiência se traduz em uma menor remoção de DQO e fenóis ficando a ETE vulnerável a aumentos de carga orgânica que limita a produção de celulose. Uma alternativa para buscar manter a biomassa retida no reator seria a adoção de um sistema de crescimento aderido denominado MBBR (Moving Bed Bioreactor), ou seja, transformar o reator convencional de lodos ativados em um reator com crescimento aderido, permitindo um aumento de eficiência e estabilidade do processo. O presente trabalho estudou em uma planta piloto, especialmente, projetado para este fim, que simula a ETE industrial. Verificou-se que com a aplicação de elementos de suporte de 10 e 20% (v/v) foi suficiente para aumentar em 6 e 12 pontos percentuais, respectivamente, a remoção de DQO solúvel para condições normais de carga, valores estatisticamente significativos. A remoção de fenóis também se demonstrou efetiva com uso de suporte aderido. / Celulosa Arauco y Constitución S.A., Planta Constitución, dispone desde el año 2007 de una Planta de Tratamiento de Efluentes de lodo activado, cuyo clarificador secundario quedó inhabilitado por un terremoto grado 8.8 en escala Richter el año 2010; mientras se reconstruye, el sistema opera abierto, con una reducida cantidad de biomasa en el biorreactor y por tanto con menores eficiencias de tratamiento, fundamentalmente reflejado en la demanda química de oxígeno y el índice de fenol, siendo una planta vulnerable a incrementos de carga orgánica, lo cual ha generado una limitante en la producción de celulosa. Una alternativa evaluada para soportar este período es la incorporación de tecnología MBBR, es decir soporte en suspensión en cuya superficie crece una biopelícula, lo cual incrementa la concentración de biomasa en el sistema y cuyas características entregan mayor resistencia a variaciones en el medio. El estudio en una planta piloto a escala, especialmente diseñada para este objeto, permite corroborar que con un 10% y 20% de soporte se obtiene un incremento en torno al 6 y 12 puntos porcentuales respectivamente de eficiencia de remoción medida como demanda química de oxígeno soluble para condiciones normales de carga, valores estadísticamente significativos. El abatimiento de fenol demostró ser muy efectivo y estadísticamente significativo con un sistema de biopelícula.
5

Estudo comparativo entre reatores de crescimento aderido e disperso pós tanques sépticos tratando esgotos domiciliares

Oliveira, Jose Dorivaldo Florencio de 27 March 2014 (has links)
Made available in DSpace on 2015-05-14T12:09:28Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 3492986 bytes, checksum: cb918a3cba1ca29e84bfc06dbb5b6d70 (MD5) Previous issue date: 2014-03-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The efficiency of removal of the biochemical oxygen demand (BOD5), chemical oxygen demand (COD), total suspended solids (TSS) and volatile suspended solid (SSV) were studied in two anaerobic reactors which received semi-settled effluent (flow limited around 3.2 times the average flow) of a septic tank, one being adhered growth (R1, with bed of gravel Nº. 4) and the other dispersed growth (R3 without support material for microbial growth). This system was installed in the University Residence at UFPB in João Pessoa-PB. The treated sewage came from two bathrooms that catered to a theoretical population of 4 inhabitants. Eleven samples of the effluent from the septic tank and the effluent from the reactors 1 and 3 were performed in the period between 28/02/2013 and 10/12/2013. The temperature and pH of the reactors were presented in the range 24.5 to 28.1 ° C and 7.3 to 8.1, respectively. Those values are from the anaerobic treatment of household sewage. The BOD5 removal efficiencies (32.8 and 27.1% in R1 and R3, respectively), COD (43.4 and 33.0% in R1 and R3, respectively), SST (56.2 and 48.0% in R1 and R3, respectively) and VSS (54.7 and 46.2% in R1 and R3, respectively) were high. It demonstrates a good applicability of these low-cost housing units which are devoid of collective sewage system in the reduction of pollution load released in water bodies systems. An analysis of variance showed no significant difference of 5% between the average of the corresponding parameters of the two reactors, suggesting that reactor that receives discharges from the attenuation peaks, there is no need of support means, which may represent a reduction in costs involved. / Estudou-se a eficiência de remoção de demanda bioquímica de oxigênio (DBO5), demanda química de oxigênio (DQO), sólidos suspensos totais (SST) e sólidos suspensos voláteis (SSV) em dois reatores anaeróbios que recebiam efluentes semi-regularizados (vazão limitada a algo em torno de 3,2 vezes a vazão média) de um tanque séptico, sendo um deles de crescimento aderido (R1, com leito de brita n°4) e o outro de crescimento disperso (R3, sem material suporte para crescimento microbiano). Este sistema foi instalado na Residência Universitária da UFPB, em João Pessoa-PB. O esgoto a ser tratado era proveniente de dois banheiros que atendiam a uma população teórica de 4 habitantes. Foram realizadas 11 coletas do efluente do tanque séptico e dos efluentes dos reatores 1 e 3, no período compreendido entre 28/02/2013 e 10/12/2013. A temperatura e o pH nos reatores se apresentaram na faixa 24,5 - 28,1 °C e 7,3 - 8,1, respectivamente, valores estes, propícios ao tratamento anaeróbio de esgotos domiciliares. As eficiências de remoção de DBO5 (32,8 e 27,1%, em R1 e R3, respectivamente), DQO (43,4 e 33,0%, em R1 e R3, respectivamente), SST (56,2 e 48,0%, em R1 e R3, respectivamente) e SSV (54,7 e 46,2%, em R1 e R3, respectivamente) foram elevadas. Isto demonstra a aplicabilidade desses sistemas de baixo custo a unidades habitacionais desprovidas de sistema coletivo de esgotamento sanitário, na redução da carga poluidora lançada em corpos aquáticos. Um teste de análise de variância demonstrou não haver diferenças significativas ao nível de 5% entre as médias dos parâmetros correspondentes nos dois reatores, sugerindo que, para reatores que recebam vazões com atenuação dos picos, não há necessidade do meio suporte, podendo representar diminuição nos custos envolvidos.

Page generated in 0.4313 seconds