Spelling suggestions: "subject:"anda distribution systems."" "subject:"ando distribution systems.""
241 |
Acquisition of electronic commerce capability : the cases of Compaq and Dell in SwedenKaplan, Michael January 2002 (has links)
Electronic commerce is in a state of growth and the number of firms engaging in electronic commerce has increased rapidly during the late 1990s. As a result, electronic commerce has become an essential part of commercial life. As firms have struggled to implement electronic commerce there have been successes and failures. Hence there is a need to improve our understanding of how electronic commerce can and should be deployed. In this thesis electronic commerce is explored and discussed in terms of what firms need to know and how they can acquire that knowledge in order to engage in electronic commerce to remain or become competitive. The focus is on the process of acquiring new capabilities for electronic commerce. Capabilities are regarded as high-performance routines that can reside within and between organisations and confer a firm with a temporary competitive advantage. These capabilities can be acquired by utilisation of four categories of means: in-house innovation, cloning, collaboration and firm purchasing. Four hypothesises for understanding and explaining capability acquisition are formulated with regard to how the means can be used. By surveying the literature, drawing on numerous research traditions in an eclectic manner, it is posited that the supply of capabilities, the current capability portfolio, the nature and maturity of the firm trajectory, and the performance of the firm influence the capability acquisition process. The cases of Compaq and Dell in Sweden are employed to investigate the issue of capability acquisition. Compaq has utilised an indirect approach working through intermediaries, while Dell has utilised a direct approach working directly with customers. The cases are analysed with the four hypothesises. Five capabilities are identified as critical for electronic commerce: addressability, interactivity, customisation, personalisation and postponement. It is shown that these capabilities are acquired in a process following a trajectory. This process involves suppliers, partners, customers and competitors. It is shown that firms working indirectly acquire capabilities mainly from competitors. In contrast, firms working directly acquire capabilities mainly from customers. Furthermore, working directly with customers – as opposed to working indirectly – is found to be a good vehicle for acquiring electronic commerce capability. / Diss. Stockholm : Handelshögsk., 2002
|
242 |
Despacho de reativos para regulação de tensão em redes de média tensão com geradores fotovoltaicos / Despacho de reactivos para regulación de tensión en redes de media tensión con generadores foto-voltaicosNegreiros Terrones, John William 06 September 2017 (has links)
Submitted by JOHN WILLIAM NEGREIROS TERRONES null (johneter@hotmail.com) on 2018-01-19T17:02:53Z
No. of bitstreams: 1
DissertaçãoJohn_JB (1).pdf: 14046795 bytes, checksum: deeec72b971c8015d40780ccc3ee8e37 (MD5) / Approved for entry into archive by Cristina Alexandra de Godoy null (cristina@adm.feis.unesp.br) on 2018-01-19T17:54:25Z (GMT) No. of bitstreams: 1
terrones_jwn_me_ilha.pdf: 14046795 bytes, checksum: deeec72b971c8015d40780ccc3ee8e37 (MD5) / Made available in DSpace on 2018-01-19T17:54:25Z (GMT). No. of bitstreams: 1
terrones_jwn_me_ilha.pdf: 14046795 bytes, checksum: deeec72b971c8015d40780ccc3ee8e37 (MD5)
Previous issue date: 2017-09-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho, propõe-se uma metodologia baseada nas incertezas da radiação solar para prever o despacho de demanda e reativos nos sistemas de distribuição radial com geradores fotovoltaicos (GFs). O objetivo dessa metodologia é melhorar o perfil da magnitude de tensão para o dia seguinte, sujeito a certas restrições operativas do sistema elétrico de distribuição. No desenvolvimento dos algoritmos de solução são considerados geradores distribuídos que têm forte dependência das variações da fonte primária de energia (principalmente sistemas fotovoltaicos), ou seja, os limites de injeção de potência dos GFs dependem das incertezas da radiação solar. Este grupo de geradores precisa de considerações que incluam as incertezas na geração de energia. Para isso, elaboram-se cenários de radiação baseado na função de distribuição de probabilidade beta. Assim, são realizados fluxos de potência probabilísticos em múltiplos cenários. Leva-se em consideração, os objetivos a serem otimizados por meio de técnicas multiobjetivo, observando principalmente, os desvios da tensão nos nós e as perdas de potência nas linhas do sistema. A metodologia proposta foi implementada em linguagem de modelagem algébrica com o AMPL para descrever o problema de otimização e resolvido usando o solver comercial CPLEX. Os sistemas testes de 34 e 123 nós foram utilizados para avaliar os modelos matemáticos e a eficiência da técnica de solução proposta para o problema de controle dos sistemas de distribuição radiais com GFs. / This work presents a methodology based on uncertainties of solar radiation to predict demand and reactive dispatch in the radial distribution systems with photovoltaic generators (GFs). The objective is to improve the voltage magnitude profile for a day ahead, subjecting to operation constraints of distribution system. In order to evaluate the optimization criteria for distribution networks, active power balance equations have to be solved. It is considered that distributed generators have a high coherence to variations of the primary energy source (mainly photovoltaic systems), where, the power injection limits of the GFs depend on the uncertainties of the solar radiation. Uncertainties in generation are needed to be considered for this type of generator. Thus, the beta probability distribution function has been employed to include different radiation scenarios in the problem formulation. The aim of this research evolves the development of an optimization tool to predict the reactive power dispatch of GFs considering the uncertainties of solar radiation. For this purpose, the probabilistic power flow is performed under various scenarios. The Multiobjective optimization problem is formulated by including the buses (nodes) voltage deviations and the power losses of distribution lines in two different objective functions. The proposed methodology was implemented in AMPL mathematical model language and solved using the commercial CPLEX solver. The 34 and 123 nodes test systems are applied to show efficiency of presented mathematical models, i.e. control of radial distribution systems with GFs, and the proposed solution method.
|
243 |
Despacho de reativos para regulação de tensão em redes de média tensão com geradores fotovoltaicos /Negreiros Terrones, John William January 2017 (has links)
Orientador: Antonio Padilha Feltrin / Resumo: Neste trabalho, propõe-se uma metodologia baseada nas incertezas da radiação solar para prever o despacho de demanda e reativos nos sistemas de distribuição radial com geradores fotovoltaicos (GFs). O objetivo dessa metodologia é melhorar o perfil da magnitude de tensão para o dia seguinte, sujeito a certas restrições operativas do sistema elétrico de distribuição. No desenvolvimento dos algoritmos de solução são considerados geradores distribuídos que têm forte dependência das variações da fonte primária de energia (principalmente sistemas fotovoltaicos), ou seja, os limites de injeção de potência dos GFs dependem das incertezas da radiação solar. Este grupo de geradores precisa de considerações que incluam as incertezas na geração de energia. Para isso, elaboram-se cenários de radiação baseado na função de distribuição de probabilidade beta. Assim, são realizados fluxos de potência probabilísticos em múltiplos cenários. Leva-se em consideração, os objetivos a serem otimizados por meio de técnicas multiobjetivo, observando principalmente, os desvios da tensão nos nós e as perdas de potência nas linhas do sistema. A metodologia proposta foi implementada em linguagem de modelagem algébrica com o AMPL para descrever o problema de otimização e resolvido usando o solver comercial CPLEX. Os sistemas testes de 34 e 123 nós foram utilizados para avaliar os modelos matemáticos e a eficiência da técnica de solução proposta para o problema de controle dos sistemas de distribuição radia... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work presents a methodology based on uncertainties of solar radiation to predict demand and reactive dispatch in the radial distribution systems with photovoltaic generators (GFs). The objective is to improve the voltage magnitude profile for a day ahead, subjecting to operation constraints of distribution system. In order to evaluate the optimization criteria for distribution networks, active power balance equations have to be solved. It is considered that distributed generators have a high coherence to variations of the primary energy source (mainly photovoltaic systems), where, the power injection limits of the GFs depend on the uncertainties of the solar radiation. Uncertainties in generation are needed to be considered for this type of generator. Thus, the beta probability distribution function has been employed to include different radiation scenarios in the problem formulation. The aim of this research evolves the development of an optimization tool to predict the reactive power dispatch of GFs considering the uncertainties of solar radiation. For this purpose, the probabilistic power flow is performed under various scenarios. The Multiobjective optimization problem is formulated by including the buses (nodes) voltage deviations and the power losses of distribution lines in two different objective functions. The proposed methodology was implemented in AMPL mathematical model language and solved using the commercial CPLEX solver. The 34 and 123 nodes test systems a... (Complete abstract click electronic access below) / Mestre
|
244 |
Uma nova metodologia para o desenvolvimento de projetos de proteção de redes ativas de distribuição de energia elétrica /Conceição, Katiani Pereira January 2018 (has links)
Orientador: Javier Sanz Contreras / Resumo: Neste trabalho, apresenta-se uma nova proposta de metodologia para alocar, determinar e es-pecificar os tipos de dispositivos de controle e proteção em redes de distribuição com geração distribuída (GD). Esta metodologia é baseada em técnicas de otimização multiobjetivo para efetuar a alocação otimizada, coordenada e seletiva destes dispositivos. O modelo é composto por duas funções objetivo que consideram aspectos econômicos e da confiabilidade da rede, e um conjunto de restrições composto por restrições físicas, operacionais e um subconjunto de restrições baseadas em regras práticas das empresas do setor de distribuição e previstas em normas técnicas nacionais e internacionais que estabelecem a especificação, coordenação e seletividade dos dispositivos de controle e proteção instalados na rede. No modelo considera-se a possibilidade de transferência de carga entre alimentadores vizinhos e a operação ilhada da GD. Dessa forma, obtém-se um modelo genérico de programação não linear inteira mista (PNLIM) cujo diferencial com relação a outros modelos matemáticos da literatura é propor que no mesmo processo de otimização seja realizada a alocação otimizada dos dispositivos de controle e proteção na rede juntamente com a coordenação do sistema de proteção. A eficiên-cia do modelo matemático é comprovada comparando-se os resultados obtidos entre dois tes-tes com o auxílio do algoritmo genético (AG) mono-objetivo que considera a ponderação dos objetivos, enquanto que para a solução ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This paper, presents a new methodology for placing, selecting and specifying the control and the protective devices system of distribution networks with distributed generation (DG). This methodology is based on multiobjective optimization techniques to perform the optimized, coordinated and selective allocation of the control and protective devices. The proposed mathematical model consists of two objective functions that consider economic factors and network continuity indexes. Physical and operational constraints are taken into account, with an emphasis on the set of constraints based on practical rules of distribution utilities defined in international technical standards, which require the specification, coordination, and selectivity of protective devices installed in the network. The possibility of load transfer from neighboring feeders and the islanded DG operation are also considered in the model. In this way, we obtain a generic model of mixed-integer nonlinear programming (MINLP) whose differential in relation to other mathematical models of the literature is to propose, in the same optimization process, the optimized allocation of the control and protective devices in the network along with the coordination of the protection system. The efficiency of the mathematical model is proven by comparing the results obtained in two tests with the aid of the genetic algorithm (GA) while for the solution of the multiobjective MINLP model the NSGA-II multiobjective genetic algor... (Complete abstract click electronic access below) / Doutor
|
245 |
Modelos matemáticos para otimização da confiabilidade de sistemas elétricos de distribuição com geração distribuídaFerreira, Gustavo Dorneles January 2013 (has links)
sensíveis têm requerido elevados níveis de confiabilidade dos sistemas de distribuição de energia. Em meio a este cenário, a proliferação de geradores distribuídos conectados próximos às cargas evidencia o surgimento de um novo paradigma na produção e utilização da energia elétrica. No entanto, muitos problemas decorrem do fato de que os sistemas de distribuição não foram projetados para incorporar unidades geradoras de energia. A estratégia completa de controle e proteção é definida sob o pressuposto do fluxo unidirecional de potência nos alimentadores. Um dos conflitos mais imediatos que surgem com a penetração da geração distribuída é relacionado ao sistema de proteção, resultado da alteração na magnitude das correntes de falta. Algumas consequências são a perda da sensibilidade e da coordenação da proteção. Se contornados estes problemas, a geração distribuída tem potencial para exercer impacto positivo sobre a confiabilidade, em especial no suporte ao restabelecimento da carga em situações de contingência. Tendo em vista estes fatores, a metodologia proposta adota uma perspectiva multicriterial para otimizar o desempenho dos sistemas de distribuição na presença da geração distribuída. Os indicadores SAIDI, SAIFI e MAIFI são formulados como modelos de otimização que possibilitam a adequação do sistema de proteção às condições operacionais impostas pela geração distribuída. Dentre os aspectos considerados incluem-se a alocação, a seletividade e a coordenação dos dispositivos de proteção. A alocação de chaves de manobras para reconfiguração do alimentador é a estratégia adotada para maximizar o efeito positivo da geração distribuída sobre a confiabilidade. As soluções dos modelos definem os locais de instalação dos dispositivos de proteção e manobras, e os ajustes dos religadores de forma independente para as unidades de fase e terra. A minimização simultânea dos indicadores é formulada como um problema de Programação Linear Inteira Mista por Metas, visando o balanço ótimo entre a redução das interrupções momentâneas e sustentadas nos sistemas de distribuição. Os modelos analíticos dos indicadores são solucionados utilizando um pacote de otimização de uso geral, baseado no método de Branch-and-Bound. A metodologia é avaliada a partir de um estudo de caso, considerando níveis crescentes de penetração da geração distribuída em um alimentador de distribuição real. Os modelos matemáticos são aplicados em cenários distintos de operação do sistema, associados à diferentes restrições econômicas. Os resultados possibilitam a avaliação do impacto da geração distribuída no restabelecimento e na proteção do sistema de forma independente. / The increasing automation of industrial processes and the sensitivity of electronic loads have required high levels of power distribution system’s reliability. In this scenario, the widespread use of distributed generators connected near the loads shows the emergence of a new paradigm in electric energy production and application. However, many problems arise from the fact that the distribution systems were not designed to deal with power generating units. The complete control and protection strategy is defined under the assumption of radial power flow. One of the most immediate conflicts that arise with the penetration of distributed generation is related to the protection system, a result of the change in fault currents magnitude. Some consequences are loss of protection coordination and sensitivity. By addressing these problems, distributed generation has the potential to have a positive impact on distribution reliability, especially in supporting load restoration during system’s contingencies. Considering these factors, the proposed methodology uses a multi-criteria approach to optimize the overall performance of distribution systems in the presence of distributed generation. The reliability indices SAIDI, SAIFI and MAIFI are formulated as optimization models that allow adequacy of the protection system in relation to the operating conditions imposed by distributed generation. The aspects considered include the allocation, selectivity and coordination of protective devices. The allocation of sectionalizing switches for feeder restoration is the strategy to maximize the positive impact of distributed generation on the system reliability. The model solutions provide the protective devices and switches locations, as well as reclosers’ settings for phase and ground units, independently. Reliability indices minimization is formulated as a Mixed Integer Linear Goal Programming problem, in order to establish the optimal trade-off between reducing momentary and sustained interruptions in distribution systems. The analytical models are solved using a general-use optimization package based on the Branch-and-Bound method. The methodology is evaluated through a case study considering increasing levels of distributed generation penetration on a real distribution feeder. The proposed mathematical models are applied in different scenarios of system operation and under different economic constraints. The results allow the evaluation of the impact of distributed generation on restoration and protection of the test system.
|
246 |
Développement de la gestion optimale de l'énergie électrique dans les îles Galápagos vers les Reséaux Intelligents / Development of optimal energy management in Galapagos Islands towards Smart GridMorales jadan, Diego 18 December 2017 (has links)
Les îles Galápagos sont un archipel d'îles volcaniques situées dans l'océan Pacifique, à 926 km à l'ouest de l'Equateur continental, dont elles font partie. Depuis 1978, les îles Galápagos sont déclarées patrimoine mondial. En raison de la croissance de la population, il existe plusieurs problèmes sociaux, économiques et environnementaux qui risquent la conservation de l'environnement des îles. Dans ce contexte, le gouvernement équatorien veut préserver son patrimoine écologique. Par conséquence, avec la participation de divers acteurs, principalement le ministère de l'Énergie et des Énergies renouvelables, il effectue plusieurs initiatives. Afin d'améliorer les services fournis sur les îles, cet objectif sera accompli grâce à la réduction de la consommation de carburants fossiles et donc des émissions de CO2. Donc, cette thèse a analysé l'impact des nouveaux services sur le réseau électrique, comme le remplacement obligatoire des véhicules conventionnels et des cuisinières pour des solutions efficaces et la proposition des solutions pour réduire les problèmes négatifs sur le réseau. En outre, une forte intégration de la génération distribuée a été considérée dans l'analyse. De plus, des solutions innovantes pour basse et moyenne tension ont été conçues et testées afin d’améliorer le service électrique sans affecter l'environnement et conserver ce patrimoine mondial. Par exemple, un programme DSM intelligent composé d'un schéma de temps d'utilisation (TOU) combiné avec la réponse de la demande (DR) a montré des résultats intéressants, l'installation d'un système de stockage d'énergie de batterie a également été testée, et les résultats de moyenne tension sont prometteurs. Un système de commutation automatique de phase a été adapté comme une solution pour réduire le déséquilibre en basse tension avec des résultats impressionnants. Le déploiement des réenclencheurs a démontré une amélioration considérable de la fiabilité avec un retour d’investissement très court. Considérant les technologies de l'information et de la communication, une pièce clé pour déployer Smart Grids, l'architecture de communication des réseaux de NAN/FAN/HAN a été abordée. Enfin, un Système de Gestion d’Energie pour la gestion optimale de l'énergie à Galápagos a été conçu. Toutes ces études représentent un défi important : la gestion optimale de l'électricité de réseau isolée sans énergie fossile. / The Galápagos Islands are an archipelago of volcanic islands located in the Pacific Ocean, 926 km west of continental Ecuador, of which they are a part. Since 1978, Galapagos Islands are accepted as Heritage World, due to the growth of the population, there are several social, economic and environmental problems, which endanger the environment conservation of the Islands.In this context, the Ecuadorian government desires to preserve its ecological heritage. Hence, with the participation of several stakeholders mainly the Ministry of Energy and Renewable Energy, it is releasing a lot of initiatives. In order to improve the general services that are provided in the islands, this goal will be achieved by means of reducing fossil fuel consumption and therefore CO2 emissions. Thus, this thesis has analyzed the impact of new services on the grid such as the mandatory replacement of conventional vehicles and cookers for efficient ones and to propose solutions for reducing negative issues originated on the network. Also, a strong integration of distributed generation is considered in the analysis.In addition, innovative solutions for both low and medium voltage have been designed and tested for improving the electrical service without affecting the environment and conserving this world heritage. For instance, a smart DSM program composed of Time of Use scheme combined with Demand Response has shown interesting results, the installation of a Battery Energy Storage System has been studied as well; the results in Medium Voltage are promising. An Automatic Phase Switching system is adapted like a solution for reducing unbalance in low voltage with impressive results. The deployment of reclosers has demonstrated a considerable improvement in the reliability with a Return on Investment very short.Considering the Information and Communication Technologies a key piece to deploy Smart Grids, the communication architecture of the Neighbor, Field and Home Area Networks is addressed. As last, an Energy Management System for performing optimal energy management within Galapagos is designed. All these studies have a significant challenge: the optimal management of electricity of isolated grid with zero fossil energy.
|
247 |
Percepção da enfermagem e avaliação da segurança do paciente na implantação de dispensários eletrônicosPozza, Camila Pereira Menezes January 2016 (has links)
Objetivos: Conhecer a satisfação e a percepção da equipe de enfermagem usuária dos dispensários eletrônicos com relação a estes equipamentos e adaptar transculturalmente o instrumento ISMP Medication Safety Self Assessment® for Automated Dispensing Cabinets para a realidade brasileira. Métodos: O estudo foi realizado em duas etapas. A primeira etapa consistiu de um estudo qualitativo, do tipo exploratório, através da realização de grupos focais com os técnicos de enfermagem e enfermeiros das unidades que possuem dispensários eletrônicos. Na segunda etapa foi realizado um estudo metodológico para tradução e validação do instrumento ISMP Medication Safety Self Assessment® for Automated Dispensing Cabinets através da realização das etapas de tradução por dois tradutores independentes, síntese das traduções, retrotradução, síntese da retrotradução, avaliação por especialistas e pré-teste. Resultados: Durante a realização dos grupos focais a equipe de enfermagem demonstrou estar satisfeita com o uso dos dispensários eletrônicos, necessitando de algumas adequações e melhorias no processo. As etapas de adaptação transcultural do instrumento foram realizadas obtendo-se um instrumento adaptado para a realidade brasileira que pode auxiliar no planejamento da implantação de dispensários eletrônicos. Faz-se necessária a realização de validação externa deste instrumento para utilização na realidade nacional. Conclusões: Neste estudo ficou evidente a satisfação dos usuários dos dispensários eletrônicos com o uso destes equipamentos e a importância de um planejamento adequado para a implantação de novas tecnologias. Demonstra-se a importância de um trabalho conjunto entre as equipes de farmácia e enfermagem na implantação e utilização de dispensários eletrônicos com foco na segurança do paciente. / Objectives: To know the satisfaction and perception of the user nursing staff of automated dispensing cabinets about this equipment and cross-culturally adapt the instrument ISMP Medication Safety Self Assessment® for Automated Dispensing Cabinets for the Brazilian reality. Methods: The study was conducted in two stages. The first stage consisted of a qualitative study, exploratory, by conducting focus groups with nursing technicians and nurses of the units that use automated dispensing cabinets. In the second stage it was carried out a methodological study for the translation and validation of the instrument ISMP Medication Safety Self Assessment® for Automated Dispensing Cabinets by performing the translation stages by two independent translators, synthesis of translations, back translation, synthesis of back translation, evaluation by experts and pretest. Results: During the course of the focus groups the nursing staff proved to be satisfied with the use of automated dispensing cabinets, requiring some adjustments and improvements in the process. The steps of cross-cultural adaptation of the instrument were carried out obtaining a tool that can assist in planning the implementation of automated dispensing cabinets adapted to the Brazilian reality. Conducting external validation of this instrument for use at the national reality is necessary. Conclusions: In this study it was evident the satisfaction of users of automated dispensing cabinets with the use of this equipment and the importance of proper planning for the deployment of new technologies. It demonstrates the importance of joint work between the pharmacy and nursing staff in the implementation and use of automated dispensing cabinets with a focus on patient safety.
|
248 |
Avaliação do impacto dos controladores de excitação na estabilidade transitória de geradores síncronos conectados em sistemas de distribuiçãoResener, Mariana January 2011 (has links)
A conexão de geradores em sistemas de distribuição, usualmente chamados de geradores distribuídos, traz novos aspectos técnicos que devem ser analisados pelas empresas distribuidoras, uma vez que os dispositivos de proteção e controle, bem como as técnicas de planejamento e otimização da operação destes sistemas consideram um sistema radial, ou seja, sem a presença de geradores. Em se tratando de geradores síncronos, sabe-se que os sistemas de excitação podem ser equipados com meios para o ajuste automático de tensão, potência reativa ou fator de potência, sendo que três diferentes modos de controle podem ser aplicados a geradores síncronos: regulação de tensão, regulação de potência reativa ou fator de potência e controle de potência reativa ou fator de potência. Ainda, sabe-se que não há um consenso entre as empresas distribuidoras de energia sobre qual o melhor modo de controle destas máquinas, e na maioria dos casos a estratégia de controle de excitação é definida através de um acordo operativo entre a empresa de distribuição de energia e o produtor independente ou autoprodutor que opera o gerador distribuído. Neste contexto, esta dissertação de mestrado tem como objetivo apresentar contribuições com relação à avaliação da estabilidade transitória de geradores síncronos conectados em sistemas de distribuição, avaliando o impacto que os diferentes modos de controle de excitação podem ocasionar, em diferentes condições de operação do sistema. Como parâmetro principal de análise tem-se o tempo crítico de eliminação de falta, obtido através de exaustivas simulações dinâmicas utilizando dados de um sistema real e considerando diferentes condições de operação do sistema, sendo estas: diferentes modos de controle da geração distribuída, modificação do ganho proporcional do controlador de fator de potência, diferentes pontos de operação da geração distribuída, diferentes cenários de carregamento do sistema e diferentes potências de geração. / The connection of generators in distribution systems, commonly called distributed generation, brings new technical issues that must be analyzed by the utilities, since protection and control devices, as well as techniques for system planning and operation optimizing consider radial systems, i.e. without the presence of generators. In the case of synchronous generators, it is known that the excitation systems can be equipped with means for automatic adjustment of voltage, reactive power or power factor, and three different control modes can be applied to synchronous generators: voltage regulation, reactive power or power factor regulation and reactive power or power factor control. It is also known that there is no consensus among the power distribution companies about which is the best control mode for use in these machines, and in most cases the excitation control strategy is defined by an operating agreement between the company and the energy producer that operates the distributed generator. In this context, this work aims to provide contributions about the transient stability of synchronous generators connected to distribution systems, evaluating the impacts that different control modes may result in different system operating conditions. The main analysis parameter is the critical clearing fault time, obtained through extensive simulations using real system data. The different system operating conditions considered in the simulations are: different control modes, variation of the power factor controller proportional gain, different operating points of the distributed generation, different system loadings and power generation.
|
249 |
Localização de faltas em alimentadores primários de distribuição de energia com a presença da geração distribuídaNunes, José Ubirajara Nuñez de January 2010 (has links)
A automatização dos sistemas de distribuição de energia e a integração de energias renováveis são duas importantes iniciativas atuais em sistemas elétricos de potência. A redução no impacto ambiental e o baixo custo comparado às grandes plantas convencionais são fatores que motivam a conexão da geração distribuída nos sistemas de distribuição. Apesar dos benefícios ambientais e econômicos obtidos com esta nova tecnologia, esta pode influenciar na operação do sistema, conduzindo a impactos técnicos que devem ser identificados. O impacto mais visível encontra-se na alteração do fluxo de potência. O alto nível de geração distribuída altera a natureza das redes de distribuição, de redes passivas, com um único sentido de fluxo de potência, para redes ativas, onde a potência flui em vários sentidos. Por conseqüência, a magnitude e a direção das correntes de falta no sistema também são modificadas. Este fato requer um ajuste dos sistemas de proteção, os quais são geralmente concebidos para operar em uma rede puramente passiva. Diversas abordagens sobre localização de faltas fundamentadas na impedância para sistemas radiais foram apresentadas em anos recentes na literatura. Estas técnicas apresentam limitações quando aplicadas a sistemas de distribuição com a presença da geração distribuída. Algumas técnicas de localização de faltas fundamentadas na impedância de seqüência positiva foram recentemente desenvolvidas a fim de incluir a presença da geração distribuída. No entanto, os sistemas de distribuição são inerentemente desequilibrados e esta característica diminui a exatidão das técnicas baseadas nas componentes modais ou de seqüência. Motivado por estes fatos, o presente trabalho ilustra os desenvolvimentos propostos em uma metodologia de localização de faltas baseada na impedância aparente utilizando a representação do sistema por coordenadas de fase. O algoritmo propõe um modelo ativo do sistema caso a falta ocorra a montante da geração distribuída, estimando a contribuição de corrente da extremidade remota da seção faltosa. Além disso, este trabalho fundamenta-se na análise pré-falta do sistema, utilizada para a determinação das impedâncias equivalentes e para a estimativa da tensão interna da máquina. O método considera a tensão interna da máquina constante entre os períodos pré-falta e durante a falta, a fim de estimar a corrente de falta do gerador, possibilitando a atualização correta das tensões e correntes faltosas do sistema. A análise numérica é realizada através de simulações computacionais em um alimentador teste sem a presença de ramificações laterais sob diferentes níveis de geração distribuída. Os resultados são comparados com técnicas atuais que compõem o estado da arte de localização de faltas a fim de avaliar o impacto da geração distribuída nas referidas metodologias. Com base nesses resultados é possível apresentar algumas melhorias obtidas através das extensões propostas. / The automation for power distribution systems and integration of renewable energy are two important current initiatives on electric power systems. The reduction in environmental impact and low cost compared to large conventional plants are factors that motivate the connection of distributed generation in distribution systems. Despite the environmental and economic benefits obtained with this new technology, this can affect the system operation, leading to technical impacts to be identified. The most visible impact is the change in the power flow. The high level of distributed generation changes the nature of distribution networks, from passive networks with a single direction of power flow, for active networks, where power flows in various directions. Consequently, the magnitude and direction of fault currents in the system are also modified. This requires an adjustment of the protection systems, which are generally designed to operate in a purely passive network. Several approaches to fault location based on impedance to radial systems were reported in the literature. These techniques have limitations when applied to distributed generation systems. Some recent positive-sequence impedance based fault location algorithms have been developed to consider the presence of distributed generation. However, the distribution systems are inherently unbalanced and this reduces the accuracy of modal or sequence components based techniques. Motivated by these, this presents proposed developments on a apparent impedance-based fault location methodology using the system representation by phase coordinates. The algorithm proposes an active system model if the failure occurs forward to the distributed generation, estimating the contribution of current from the remote end section of the fault. Moreover, this work is based on analysis of the pre-fault system, used to determine the equivalent impedances and to estimate the machine internal voltage. The method treats the machine internal voltage as constant between the pre and the fault period, in order to estimate the fault current infeed by generator. Numerical analysis is carried out through computer simulations on a test feeder without the presence of ramifications at different levels of distributed generation. The results are compared with current techniques that make up the state of the art of fault location in order to assess the impact of distributed generation in these methodologies. Based on these results it is possible to make some improvements resulting from the proposed extensions.
|
250 |
Localização de defeitos em alimentadores primários subterrâneos : formulação estendida baseada na impedância aparenteFilomena, André Darós January 2008 (has links)
O presente trabalho apresenta uma abordagem estendida para o diagnóstico de faltas em sistemas subterrâneos de distribuição de energia. O esquema proposto desenvolve modificações às técnicas de localização de defeitos em sistemas de distribuição aéreos baseadas no cálculo da impedância aparente, adaptando-as para a aplicação em alimentadores primários de topologia subterrânea. Sistemas subterrâneos estão associados à alta confiabilidade, com índices reduzidos de interrupção devido a suas características construtivas, que impedem a ocorrência de perturbações devido a fenômenos climáticos, mecânicos ou humanos. No entanto, as falhas em cabos subterrâneos são tipicamente permanentes, exigindo a substituição da seção de linha defeituosa para o restabelecimento do sistema. De forma distinta às redes aéreas, onde a localização de defeitos pode ser realizada por meio de inspeções visuais, a topologia subterrânea impossibilita a utilização desta abordagem. Embora o processo de digitalização dos esquemas de proteção de alimentadores primários tenha incentivado o desenvolvimento de inúmeras metodologias para a localização de defeitos em redes de distribuição aéreas, características típicas de redes de distribuição subterrâneas não foram contempladas. Nestes sistemas, a aplicação das técnicas desenvolvidas para sistemas aéreos resulta em estimativas errôneas da distância da falta. O esquema proposto visa a superar esta deficiência dos algoritmos de localização tradicionais, adaptando-os às características típicas de redes de distribuição subterrâneas. A formulação desenvolvida se baseia no cálculo da impedância aparente, o qual poderá ser incorporado como sub-rotina de relés de proteção de arquitetura digital. Além de disponibilizar a estimativa da distância da falta, o esquema de localização de defeitos proposto obtém uma estimativa das resistências de falta associadas à perturbação. A metodologia utiliza como dados de entrada os sinais de tensão e corrente referentes aos períodos de pré-falta e durante a perturbação, e propõe uma compensação da componente capacitiva, característica típica e não-desprezível de cabos subterrâneos. De modo a contemplar a existência de ramificações laterais, o esquema de localização propõe a utilização de sistemas radiais equivalentes, determinados a partir de rotinas de fluxo de potência trifásico. Tendo em vista o comportamento randômico do carregamento em sistemas de distribuição, a metodologia propõe, ainda, uma análise do perfil de carga durante o período pré-falta. Para possibilitar uma análise da eficiência do método proposto, testes comparativos com uma técnica de localização de defeitos para redes de distribuição de topologia aérea recentemente proposta foram realizados. De modo a validar o esquema de localização de defeitos proposto, foram executadas inúmeras simulações computacionais a partir de dados reais de um alimentador subterrâneo. O desempenho do esquema de diagnóstico de faltas foi avaliado frente aos aspectos de: resistência de falta, distância da falta, ângulo de incidência de falta, existência de cargas desequilibradas e variações no carregamento do sistema. Os resultados obtidos demonstram a viabilidade da aplicação da metodologia proposta para a localização de defeitos em sistemas de distribuição subterrâneos. / This work presents an extended approach for underground power distribution system fault location. The scheme develops modifications in the proposed impedance-based fault location techniques for overhead distribution systems, adapting it for underground feeders. Under-ground systems are associated to high reliability, with low interruption rates due to its con-struction characteristics, which avoid the fault occurrence from climatic, mechanics or human interference. However, the underground cables damages are typically permanent, requesting the damaged line section substitution before system restoration. Fault location on overhead systems can be assisted by visual inspection, on underground system, this approach can not used. Although the primary feeder protection scheme's digitalization process has stimulated the development of several fault location schemes for overhead feeders, typical underground's system characteristics were not considered. In these systems, the application of the techniques used on overhead systems results in erroneous fault distance estimates. The proposed methodology aims to overcome this limitation of traditional fault location algorithms, adapting it to the typical underground systems characteristics. The proposed formulation is based on the apparent impedance calculation, and can be included as a sub-routine in digital protection relays. Besides the fault distance estimates, the fault diagnosis scheme also calculates the fault resistances associated to each disturbance. The fault location scheme uses as input data the voltage's and current's signals before and during the fault, and also proposes a capacitive current compensation. The fault location technique also proposes the usage of equivalent radial systems, calculated through three-phase load flow techniques, to allow the algorithm coverage on laterals and sub-laterals. Due to the random load profile of distribution systems, the technique develops a load profile analysis during the pre-fault period. In order to provide efficiency analysis of the proposed formulation, comparative testes with a recently proposed fault location technique was realized. To validate the proposed fault location algorithm, several fault simulations were executed using real underground feeder data. The proposed fault location scheme performance was evaluated considering the following aspects: fault resistance, fault distance and inception fault angle. Also, the methodology was analyzed considering different load profiles, including unbalanced loads and load variation. The obtained results demonstrate the applicability of the proposed formulation for fault location in underground distribution systems.
|
Page generated in 0.1133 seconds