• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência do cloreto de cálcio e da clorexidina em propriedades físico-químicas de um material retrobturador à base de Bis-EMA/MTA / Influence of calcium chloride and chlorhexidine on physical-chemical properties of a Bis-EMA/MTA-based root-end filling material

Farina, Giane Linhares 12 August 2016 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-19T14:45:14Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Influência do cloreto de cálcio e da clorexidina em propriedades físicoquímicas.pdf: 1059787 bytes, checksum: b05d8b93c55294e17664731b40cb68d7 (MD5) / Made available in DSpace on 2017-06-19T14:45:14Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Influência do cloreto de cálcio e da clorexidina em propriedades físicoquímicas.pdf: 1059787 bytes, checksum: b05d8b93c55294e17664731b40cb68d7 (MD5) Previous issue date: 2016-08-12 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / A incorporação de compostos resinosos fotopolimerizáveis ao MTA tem sido proposta para melhorar as suas propriedades e a reduzir o tempo de presa. O objetivo deste estudo foi avaliar a radiopacidade, sorção, solubilidade e atividade antibacteriana de um material retrobturador de cura dual à base de Bis-EMA/MTA (MTA-E) em comparação com o agregado trióxido mineral (MTA) e avaliar o efeito de CaCl2 sobre estas propriedades. Outro objetivo do estudo foi analisar a influência da clorexidina (CLX) sobre o pH, capacidade de liberação de ions de cálcio e tempo de presa do MTA-E em comparação com MTA-branco (MTA-B). Para análise de radiopacidade espécimes de cada material (MTA-B; MTA-E + 5% de CaCl2; MTA-E) foram preparados com anéis metálicos (6mm de diâmetro e espessura de 1mm). Os valores de radiopacidade foram determinados de acordo com a densidade radiográfica (mm Al). Para avaliar a sorção e solubilidade, espécimes (n = 10) de cada material foram preparados com o auxílio de uma matriz de acordo com as especificações ISO 4049/2009. O teste contato direto (TCD) foi utilizado para avaliar a atividade antibacteriana de cada material contra E. faecalis em 30 minutos e 24 horas após a manipulação. Um grupo contendo MTA-E + CLX 2% foi incluído para os testes a seguir. A liberação de íons de cálcio e o pH foram analisados com espectrofotômetro e peagâmetro, respectivamente. O tempo de presa de cada material foi verificado utilizando agulhas de Gilmore. Os dados foram analisados por análise de variância e teste de Tukey (P = 0,05). O MTA-E mostrou radiopacidade superior ao MTA (P <0,05) e a adição de 5% CaCl2 não alterou a sua radiopacidade (P> 0,05). Todos os materiais ganharam massa após 7 dias de imersão em água, enquanto que a adição de 5% de CaCl2 aumentou a absorção de água do MTA-E. O MTA-E + 5% de CaCl2 apresentou a maior solubilidade e foi estatisticamente diferente dos outros materiais (P <0,05). Todos os materiais foram 100% eficazes contra E. faecalis no prazo de 30 minutos após a manipulação (p = 0,005). Após 24 horas foi observada uma redução da atividade antibacteriana do MTA-E. O pH do MTA-E + CLX foi superior ao dos outros dois materiais após 7 dias e inferior após 30 dias (p <0,05). A adição de CLX aumentou a liberação de íons de cálcio do MTA-E para níveis estatisticamente semelhantes ao MTA-B. MTA-E mostrou um menor tempo de presa inicial e final em comparação com MTA-B (P <0,05). A adição de CLX 2% tanto no MTA como no MTA-E impediu a presa dos materiais. A adição de CLX ao MTA-E aumentou o seu pH e a liberação de íons cálcio. Enfim, o monómero Bis-EMA adicionado ao MTA formou um material (MTA-E) com maior radiopacidade e menor atividade antibacteriana do que o MTA-B. A adição de 5% de CaCl2 não alterou a sua radiopacidade enquanto aumentou a sua absorção de água, solubilidade e atividade antibacteriana. A adição de CLX ao MTA-E aumentou o pH e liberação de íons cálcio, mas impediu a presa do material. / The incorporation of resinous light-curable compounds to MTA has been proposed to improve the properties and to reduce the setting time. The aim of this study was to evaluate the radiopacity, sorption, solubility and antibacterial activity of a Bis-EMA / MTA based dual-cure retro-filling material (MTA-E) in comparison with mineral trioxide aggregate (MTA) and to evaluate the effect of CaCl2 on these properties. Another aim of the study was to evaluate the influence of 2% chlorhexidine (CHX) on pH, calcium ion release and setting time of an E-MTA compared to white-MTA (W-MTA). For radiopacity analysis specimens of each material (PCC; E-MTA + 5% CaCl2; E-MTA) were prepared with metal rings (6 mm diameter, and 1 mm thickness). The radiopacity values were determined according to the radiographic density (mm Al). To evaluate the sorption and solubility, specimens (n = 10) were prepared for each material with the aid of a matrix according to ISO 4049/2009 specifications. The direct contact test (DCT) was used to assess the antibacterial activity of each material against E. faecalis at 30 minutes and 24 hours after manipulation. A group of E-MTA + 2% CHX was included for the following tests. The calcium ions release and pH were analyzed with a spectrophotometer and pH meter, respectively. The setting time of each material was analyzed with Gilmore needles. Data were analyzed by analysis of variance and Tukey test (P = 0.05). E-MTA showed higher radiopacity than W-MTA (P <0.05) and the addition of 5% CaCl2 did not change its radiopacity (P> 0.05). All materials gained mass after 7 days in water immersion, while the addition of 5% CaCl2 increased water sorption of E-MTA. E-MTA + 5% CaCl2 showed the highest solubility and was statistically different (p <0.05) from the other materials. All materials were 100% effective against E. faecalis within 30 minutes of manipulation (p = 0.005). After 24, hours a reduction in the antibacterial activity was observed for E-MTA. However, the addition of CaCl2 increased the antibacterial activity of E-MTA. The pH of the E-MTA + CHX was higher than the other two materials after 7 days and lower after 30 days (p <0.05). The addition of CHX increased the calcium ion release of E-MTA to levels statistically similar to W-MTA. E-MTA showed shorter initial and final setting time, compared with W-MTA (P <0.05). The addition of 2% CHX to both MTA and E-MTA prevented setting of material. Finally, Bis-EMA monomer added to the MTA formed material (E-MTA) with higher radiopacity and lower antibacterial activity than the W-MTA. The addition of 5% CaCl2 did not change its radiopacity while increasing its water sorption, solubility and antibacterial activity. The addition of CHX to E-MTA increased its pH and calcium ion release, but prevented setting of the material.
2

Mapeamento tridimensional do ápice radicular em relação às corticais ósseas externas e estruturas anatômicas adjacentes /

Ferrari, Carlos Henrique. January 2017 (has links)
Orientador: Frederico Canato Martinho / Banca: Márcia Carneiro Valera Garakis / Banca: Cláudio Antonio Talge Carvalho / Banca: Luiz Alexandre Thomaz / Banca: Maria Rachel Figueiredo Penalva Monteiro / Resumo: O conhecimento da posição topográfica dos ápices dentários em relação às corticais ósseas externas e estruturas anatômicas é de importância para a endodontia, sobretudo quando da instituição de técnicas com sobreinstrumentação. A tomografia computadorizada de feixe cônico (TCFC) permite uma análise tridimensional da localização do ápice radicular, estimando os riscos em relação a essas estruturas. Os objetivos desta pesquisa foram: a) aferir a medida linear entre os ápices radiculares de dentes posteriores e canino superiores e o seio maxilar e entre os ápices de dentes posteriores inferiores e o canal mandibular, relacionando os achados com gênero e idade; b) comparar as medições realizadas em tomografias entre ápices e estruturas anatômicas, com as realizadas em radiografias panorâmicas; c) verificar a proximidade dos ápices radiculares dos dentes superiores com a respectiva cortical óssea externa adjacente e dos ápices radiculares dos dentes inferiores com as corticais ósseas externas vestibular e lingual; d) verificar a ocorrência de fenestrações apicais, em todos os grupos dentais e e) classificar riscos de sobreinstrumentação baseando-se nas medidas lineares entre ápices radiculares e estruturas anatômicas/ corticais ósseas externas. Foram selecionados 800 TCFCs e 200 radiografias panorâmicas obtidas de pacientes com indicações diversas. Na TCFC, foram encontradas médias entre os ápices radiculares e o seio maxilar, variando de 0,37mm até 6,22mm, e na mandíbula, entre o... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: It is important to know the topographic position of dental root apices in relation to external cortical bones and adjacent anatomical structures for endodontics, mainly regarding the use of over-instrumentation techniques. Cone beam computed tomography (CBCT) allows for analysis of the root apex position and estimation of the risks in relation to these structures. The objectives of this study were: a) to assess the linear measurement between root apices of posterior teeth and upper canine and maxillary sinus as well as between apices of lower posterior teeth and mandibular canal according to gender and age; b) to compare tomographic measurements of apices and anatomical structures to those from panoramic radiographs; c) to verify the proximities of the root apices of upper teeth to corresponding adjacent cortical bones and of lower teeth to buccal and lingual cortical bones; d) to verify the occurrence of apical fenestrations in all dental groups; and e) to assess the risks of overinstrumentation based on linear measurements between root apices and anatomical structures/external cortical bones. A total of 800 tomographs and 200 panoramic radiographs were selected. CBCT images showed mean distances between root apices and maxillary sinus ranging from 0.37mm to 6.22mm and between root apices and mental foramen ranging from 2.81mm to 4.92mm. By comparing the tomographs to panoramic radiographs, over-estimation and sub-estimation were found in the maxillary and mandibular measurements, respectively (P < 0.01). The distances between each root apex and corresponding cortical bone were ranked according to distance, with the majority of the apices located less than 1 mm from the cortical bone in the maxilla and greater than 3mm in the mandible. Higher rates of fenestrations were found in the maxilla, whereas lingual bone plate was more affected in the mandible. ...(Resumo completo, clicar acesso eletrônico abaixo) / Doutor

Page generated in 0.0564 seconds