91 |
Injectable system and scaffolds to promote endochondral mechanism for bone regenerationOliveira, Serafim Paulo Melo de January 2008 (has links)
Tese de doutoramento. Engenharia Biomédica. Faculdade de Engenharia. Universidade do Porto, Department of Basic Sciences and Craniofacial Biology. New York University College of Dentistry. 2008
|
92 |
Bioactive ceramics with high specific surface area for osteoconductionTeixeira, Sandra Maria da Silva January 2008 (has links)
Tese de doutoramento. Ciências de Engenharia. Faculdade de Engenharia. Universidade do Porto, Faculdade de Ciências da Saúde. Universidade Fernando Pessoa. 2008
|
93 |
La enseñanza de la ética y bioética como eje transversal, Escuela de Enfermería, Universidad Católica Santo Toribio de Mogrovejo, Chiclayo-PerúSovero Ortiz, Elvia Rosa January 2012 (has links)
La presente investigación cualitativa tuvo como objetivos describir y analizar cómo es la enseñanza de la ética y bioética cómo eje transversal. El marco conceptual estuvo respaldado por León Correa Francisco Javier, Pastor García Luis Miguel, Polaino Lorente Aquilino y Tomás Gloria María y Garrido. Los sujetos de investigación lo conformaron 5 profesoras y 7 alumnas de enfermería, muestra obtenida por saturación, y con consentimiento informado. El escenario de estudio lo constituyó la escuela de enfermería de la Universidad Católica Santo Toribio de Mogrovejo. Para la recolección de datos se utilizó la entrevista semiestructurada a profundidad, los datos obtenidos fueron procesados por análisis de contenido; en el proceso de la investigación se consideraron los criterios éticos y de rigor científico; surgiendo las siguientes categorías: develando la ética y bioética como eje transversal en las asignaturas, como segunda categoría: falencias de la ética y bioética como eje transversal, con las subcategorías: necesidad de formación del profesor en ética y bioética; escasa uniformidad de los equipos de profesores y como última categoría: mejoras en la didáctica y metodología de la ética y bioética. Obteniendo como consideraciones finales que la ética y bioética requiere ser abordada desde la sumilla, competencias, temática y ser evaluada, para ello, los profesores requieren formación continua y actualizada.
|
94 |
Uma arquitetura de redes de sensores do corpo humano / A body sensor networks architectureBarbosa, Talles Marcelo Gonçalves de Andrade 02 1900 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2008. / Submitted by wesley oliveira leite (leite.wesley@yahoo.com.br) on 2009-09-22T18:23:57Z
No. of bitstreams: 1
Tese_TallesMarceloGABarbosa.pdf: 3499007 bytes, checksum: bd325b24cb8d866bd3a67728c5a245fc (MD5) / Approved for entry into archive by Luanna Maia(luanna@bce.unb.br) on 2009-09-23T14:08:39Z (GMT) No. of bitstreams: 1
Tese_TallesMarceloGABarbosa.pdf: 3499007 bytes, checksum: bd325b24cb8d866bd3a67728c5a245fc (MD5) / Made available in DSpace on 2009-09-23T14:08:39Z (GMT). No. of bitstreams: 1
Tese_TallesMarceloGABarbosa.pdf: 3499007 bytes, checksum: bd325b24cb8d866bd3a67728c5a245fc (MD5)
Previous issue date: 2008-02 / As Redes de Sensores do Corpo Humano (RSCH) devem ser projetadas para operar de maneira autônoma. Por outro lado, devem oferecer mecanismos que remetam o controle aos profissionais da saúde. Um grande desafio no projeto de RSCH é oferecer de forma adequada (com transparência) acesso às configurações internas da rede e dos sensores, sem excluir a capacidade de operação autônoma desses sistemas. A tarefa de configuração de RSCH é usualmente realizada por desenvolvedores especializados, profissionais da Computação. Entretanto, para que essa tecnologia se torne clinicamente viável, é necessário que os próprios profissionais da área de saúde possam fazê-la. Esses profissionais são os responsáveis legais pelas decisões acerca do monitoramento dos pacientes, mesmo que essas decisões tenham sido geradas pelo próprio sistema. Esta tese discute os pressupostos supracitados e propõe um modelo capaz de acomodar essas necessidades. Dois conceitos relacionados à programação de RSCH são tratados neste trabalho: (i) programação (em tempo de compilação) e (ii) configuração (em tempo de execução). A programação refere-se à definição dos artefatos de software e algoritmos que são embutidos dentro dos sensores. Em RSCH a inclusão dessa funcionalidade requer uma interface para programação adequada aos profissionais da saúde e também de compiladores inteligentes. O compilador inteligente é um conceito novo apresentado nesta tese. Tem como objetivo aumentar a eficiência no uso dos sensores, considerando os requisitos da aplicação, os recursos do hardware e, principalmente, o conhecimento especialista para formulação das políticas que organizam o funcionamento do sistema. Como exemplo, a inclusão de mecanismos e políticas para tratar da economia de energia podem ser ajustadas por essas estruturas. A configuração refere-se à capacidade de ajuste do sistema sem a necessidade de reiniciar o hardware. Esse conceito possibilita maior interatividade entre o profissional da saúde e o sistema. Como requisito, os sensores precisam de mecanismos que possibilitem maior controle acerca das tarefas executadas. Uma possível solução é a utilização de estruturas de dados que possibilitem a aplicação do conceito de multitarefa nos sensores. Como contribuição maior é apresentada uma arquitetura de software denominada SOAB (Software Architecture for Body-worn Sensor etworks Project). A arquitetura SOAB é constituída por quatro camadas independentes: (i) uma interface para programação; (ii) um middleware para interconexão da RSCH com a Internet; (iii) um servidor para execução dos serviços solicitados pelos usuários e (iv) um sistema operacional com suporte para multitarefa, que será embutido nos nós sensores. Esse sistema operacional foi chamado MedOS. Tem como uma de suas funcionalidades aumentar o tempo de funcionamento dos nós sensores, promovendo a redução do consumo de energia elétrica por meio do escalonamento de tarefas com base em políticas adaptadas para aplicações biomédicas. __________________________________________________________________________________ ABSTRACT / Body Sensor Networks (BSNs) must be designed to work autonomously. On the other hand, they must provide mechanisms that allow their control by healthcare personnel, as the clinical assessment of these professionals should always be the basis for the programming strategy. A great challenge in BSN software design is to provide, in a transparent way, access to the internal configurations of the networks and their sensor nodes without excluding their capability for autonomous operation. In order to provide such feature, specific models are needed in the design of software architectures for BSN’s, which include programmability as one of their functional requisites. The success of this approach can lead to a paradigm shift, since healthcare professionals will be able to act as the actual programmers and maintainers of the BSN. The programming of this type of system is usually performed by specialized engineers. However, if this technology is to become clinically useful, it is essential that the healthcare professionals are able to program the system. This thesis discusses the hypothesis abovementioned and proposes a model that will lead to the achievement of these objectives. Two important concepts related to programmability in BSNs are treated in this work: (i) deployment-time programmability and (ii) runtime set-up. The deployment-time programmability refers to the definition of software artifacts and algorithms that are embedded in the sensor node. In BSN’s, the inclusion of this functionality requires a programming interface that is suitable for healthcare personnel, as well as intelligent compilers. Intelligent compilers is a new concept presented in this thesis and its main purpose is to increase the effectiveness of the system’s use, considering the application’s requirements, the hardware possibilities and mainly the specialist’s knowledge to increase the applications lifetime. Consequently, it is possible to maintain the capability for autonomous operation of the BSN and still offer tools that can be used for people with little grasp on programming languages for programming of these systems. As an example, the inclusion of mechanisms and policies for energy saving could be treated by these structures. The runtime set-up refers to the capability for adjustments in run-time. The BSN should provide interactivity between the healthcare professional (the BSN manager) and the system. As a requisite, sensor nodes need mechanisms that allow a better control of the tasks that are being run. A possible solution is the use of data structures that allow preemptive multitasking. The main contribution of this work is the proposal of a software architecture named SOAB (Software Architecture for Body-worn Sensor Networks Project). The SOAB architecture is composed of four independent layers: (i) a programming interface; (ii) middleware for interconnecting BSN’s to the Internet; (iii) a server for processing users’ requests; (iv) a multitasking operating system. It helps to increase the lifetime of batteries by scheduling tasks based on customized policies, designed for taking into account the specificities of biomedical applications.
|
95 |
Aplicação do questionário EQ-5D em formato eletrônico : equivalência com a versão em português brasileiro do formato em papelBagattini, Ângela Maria January 2015 (has links)
Introdução: Entre os métodos de avaliação econômica em saúde, as avaliações de custo-utilidade ponderam custos e benefícios para comparar diferentes intervenções, utilizando como medida de desfecho índices de utilidade, que representam as preferências dos pacientes por determinados estados de saúde. O questionário de qualidade de vida EQ-5D gera este tipo de índice e foi criado para ser utilizado nas avaliações de custo-utilidade. Devido ao crescimento do uso de métodos eletrônicos para coleta e propagação de dados na área da saúde e pela facilidade de registro e manuseio dos dados em sistemas eletrônicos, o objetivo deste estudo foi verificar a equivalência de mensuração entre a versão em papel com a versão adaptada em tablet do questionário EQ-5D. Métodos: Foi realizado um estudo transversal com uma amostra composta por 509 indivíduos alfabetizados, com idade entre 18 e 64 anos, selecionados aleatoriamente da população geral das cidades de Porto Alegre e Belo Horizonte. Os sujeitos de pesquisa responderam ao questionário EQ-5D em dois momentos, com intervalo de no mínimo 24 horas e no máximo de 7 dias. Os participantes foram selecionados aleatoriamente em uma das tres amostras: uma com o grupo de teste re-teste, em que responderam nas duas ocasiões em meio eletrônico (tablet), e grupo crossover com uma amostra que respondeu papel e depois tablet e outra amostra que respondeu tablet e depois papel. Para avaliação da concordância dos métodos foi comparado os escores do EQ-5D e os valores da escala análogo visual (EAV) medidos por ambos os meios através do Coeficiente de Correlação Intra classe (CCI) e coeficiente Kappa. Resultados: Entre os entrevistados predominou o sexo feminino. Para o grupo crossover os resultados de concordância com CCI foram bastante satisfatórios, nos que responderam tablet-papel o CCI de 0,76 IC (0,58;0,89) no EQ-5D e 0,77 IC (0,68;0,84) na EAV e em papel- tablet o CCI foi de 0,75 IC (0,67;0,85) na EAV e 0,83 IC (0,75|0,89) no EQ-5D. Para o grupo teste re-teste (amostra tablet-tablet) CCI de 0,79 e intervalo de confiança IC (0,66;0,87), na EAV e no EQ-5D CCI de0,85 IC (0,73|0,91), e em com consistência interna semelhantes entre os métodos nos valores de utilidade e os valores da EAV. Conclusões: Os dois métodos de avaliação do EQ-5D são comparáveis e a aceitabilidade dos métodos é semelhante. / Background: Among the methods of economic evaluation in health, assessments of cost-utility are considering costs and benefits in order to compare different health interventions, through methods of assessing quality of life based on preferences, which are the result of utility scores that represent patient preference. The quality of life questionnaire EQ-5D is designed to be used in evaluations of cost-utility and is the most widely used and recommended in this type of analysis. Because of the growing use of electronic methods for collecting and propagation of information on health and ease of collection and handling of data in electronic systems, the aim of this study was to evaluate the measurement equivalence between the original paper version to version adapted tablet of EQ-5D questionnaire. Methods: Was conducted a cross-sectional study with a sample of 509 literates individuals aged 18-64 years were randomly from the general population of the cities of Porto Alegre and Belo Horizonte selected. Research subjects answered the questionnaire EQ-5D in two stages, with an interval of at least twenty four hours and a maximum of seven days to avoid the learning effect, carry-over. Participants were randomly selected to answer the test-retest group, which responded both times by electronic means (tablet) or were selected to answer the intersection group, cross over, which responded in the traditional method and also the electronic method, half group answered in the order paper / tablet and the other party in tablet / paper. To assess the concordance of the electronic method with the traditional means of the questionnaire compared the scores of the EQ-5D and the values of the visual analogue scale (VAS) through the Intra-class Correlation Coefficient (ICC). Results: Among respondents predominantly female. For the group crossover the results of agreement with ICC are satisfactory, who responded tablet-paper the ICC of 0.76 CI (0.58, 0.89) in the EQ-5D and 0.77 CI (0.68; 0.84) in the EAV and paper- tablet the ICC was 0.75 CI (0.67, 0.85) in the EAV and 0.83 CI (0.75 | 0.89) in the EQ-5D. For the test re-test group (tablet-tablet sample) ICC of 0.79 and confidence interval CI (0.66, 0.87) in VAS and EQ-5D CCI de0,85 IC (0.73 | 0.91), and with similar internal consistency between the methods in utility values and the values of VAS. Conclusions: The interviewed answers from the tablet and paper versions of the EQ-5D Quality of Life Questionnaire are comparable. The test-retest of the tablet version demonstrated reliability and both methods have high acceptability by the interviewed sample.
|
96 |
Generación de patrones de interferencia utilizando sonoelastografía cuantitativa bajo el principio de holografíaArroyo Barboza, Johnny Junior 15 February 2018 (has links)
Por lo general, la presencia o aparición de ciertas enfermedades está relacionada a la variación de las propiedades mecánicas (en particular, elásticas) del tejido blando. Entre las técnicas de caracterización de estas propiedades se encuentra la Sonoelastografía Cuantitativa, la cual se ha venido desarrollando en el Laboratorio de Imágenes Médicas de la PUCP, y cuyo funcionamiento está basado en la aplicación de vibraciones mecánicas de baja frecuencia sobre el tejido, con la finalidad de analizar la forma de propagación de la excitación inducida y caracterizar de manera cuantitativa las propiedades mecánicas mostradas.
Inicialmente se emplearon dos técnicas sonoelastográficas: Sonoelastografía de Crawling Waves (CWS) y Holografía de Onda de Corte (SWH), las cuales fueron aplicadas sobre un maniquí homogéneo de 10 % de concentración de gelatina y sobre uno de 15% de concentración de gelatina, estimando la velocidad de onda de corte en ambos maniquíes, así como la desviación estándar.
A continuación se propone la Sonoelastografía por Holografía Digital (DHS), una técnica que presenta un esquema experimental sencillo, con menor instrumentación y por ende con potencial para aplicaciones in vivo, a diferencia de las dos técnicas previamente analizadas. Se diseña un algoritmo para la formación de patrones de interferencia, a partir de los cuales se estimó la velocidad de propagación y la desviación estándar de un maniquí de 10% de concentración de gelatina y otro de 15% de concentración.
Por último, se comparan los resultados obtenidos con las tres técnicas, usando al tiempo de vuelo para poder calcular un valor de velocidad de referencia. Para el caso del maniquí de 10% de concentración, el valor de referencia es de 2.0064 m/s, con CWS se obtuvo 2.0111 ± 0.0383 m/s, con SWH 1.9167 ± 0.0477 m/s y con DHS 2.1067 ± 0.0691 m/s. Por otro lado, para el maniquí de 15% de concentración se obtuvo un valor de referencia de 2.7916 m/s, con CWS se obtuvo 2.8170 ± 0.0565 m/s, con SWH 2.8560 ± 0.1600 m/s y con DHS 2.1449 ± 0.0957 m/s. Para cuantificar la precisión de la estimación se calculó el error relativo entre el resultado obtenido con la técnica propuesta DHS y valor de referencia en cada caso. De esta manera, el error fue de 4.99% en el caso del maniquí de 10% de concentración, mientras que en el maniquí de 15% fue de 23.16%.
En tal sentido, se concluye que la técnica realiza una adecuada estimación de velocidad de corte para maniquíes de baja concentración, pues a medida que la concentración aumenta el error en la estimación también lo hace. / Tesis
|
97 |
Validação do guia de acolhimento com classificação de risco em pediatria na prática clínica / Validation of the guide with pediatric risk classification in clinical practiceVeras, Joelna Eline Gomes Lacerda de Freitas 30 December 2016 (has links)
VERAS, J. E. G. L. F. Validação do guia de acolhimento com classificação de risco em pediatria na prática clínica. 2016. 157 f. Tese (Doutorado em Enfermagem) - Faculdade de Farmácia, Odontologia e Enfermagem, Universidade Federal do Ceará, Fortaleza, 2016. / Submitted by Programa de Pós-graduação em Enfermagem PPGENF (pgenfermagem.ri@gmail.com) on 2017-07-24T12:22:29Z
No. of bitstreams: 1
2016_tese_jeglfveras.pdf: 3025292 bytes, checksum: 1e51fed633cdf99fd1e34b0f77458d42 (MD5) / Approved for entry into archive by Erika Fernandes (erikaleitefernandes@gmail.com) on 2017-07-24T13:23:47Z (GMT) No. of bitstreams: 1
2016_tese_jeglfveras.pdf: 3025292 bytes, checksum: 1e51fed633cdf99fd1e34b0f77458d42 (MD5) / Made available in DSpace on 2017-07-24T13:23:47Z (GMT). No. of bitstreams: 1
2016_tese_jeglfveras.pdf: 3025292 bytes, checksum: 1e51fed633cdf99fd1e34b0f77458d42 (MD5)
Previous issue date: 2016-12-30 / With overcrowding and prolonged waiting time in emergencies, the Risk Rating Reception (RRR) of patients, has become an important strategy to improve the quality of care. The Guide RRR in Pediatrics is a clinical evaluation technology, easy to handle and simple presentation, used by nurses in the evaluation of clinical indicators and biophysiological parameters from the main complaint, to adequately identify the priority of patient care, according to the five classification levels: red (Priority I), orange (priority II) yellow (priority III), green (priority IV) and blue (priority V). The objective of the study was to validate the Guide to RRR in Pediatrics in clinical practice. Methodological study, developed in three stages. In the first stage, the content of the first version of the guide was reviewed, through the analysis of two experts on the theme. In the second stage, the interobserver reliability of the 2nd version of the guide between the researcher and two nurses (E1 and E2) trained by the researcher with 206 children and / or adolescents in June 2016 at a pediatric municipal hospital in Fortaleza- CE. In the third stage, the second version of the guide was applied in clinical practice with 400 participants, exclusively by the researcher, in July and August of 2016, in that institution. Data were analyzed in SPSS 20.0, using the Kappa index with a 95% confidence interval (CI) for reliability analysis. The effect of the use of the guide in clinical practice was evaluated through the association between the risk classification and the variables age, sex, weight, risk discriminator, procedures performed and destination after discharge by Fisher-Freeman-Halton exact tests considering statistically significant when p <0.05 and the likelihood ratio with 95% CI. The variables that presented values of p <0.20 entered into the multivariate logistic regression model. The results showed a revised guide in its content, structure and layout, valid and reliable. There was high agreement (Kappa = 0.701) between the researcher and E1 and almost perfect (Kappa = 0.847) with E2, being p <0.001. There was a statistically significant association between risk classification and risk discriminators (p = 0.0001), emergency procedures (p <0.0001) and patient's destination (p = 0.0132). The prevalence of the risk discriminator was found to be respiratory change (207; 51.8%) at priority level IV (green color) (117; 56.5%). The odds ratio (RC) of risk discriminators to be more urgent (orange, yellow and green) compared to non-urgent (blue) ranged from 1 to 12.3 times and 95% CI [1-82,7]. Of the 15 items of greatest urgency analyzed in the guide, more than half (8; 53.3%) had a statistically significant association and 10 (66.7%) had CR> 1, that is, they were more likely to be classified at the level of priority. It was concluded that the Guide to RRR in Pediatrics is a reliable valid health technology,
capable of classifying the child's risk in emergency situations to establish the order of priority of care, in order to minimize errors of decision-making by nurses, making possible humanized and quality assistance. / Com a superlotação e o tempo de espera prolongado nas emergênicia, o Acolhimento com Classificação de Risco (ACCR) de pacientes, tornou-se importante estratégia de melhoria da qualidade do atendimento. O Guia de ACCR em Pediatria é uma tecnologia de avaliação clínica, de fácil manuseio e apresentação simples, usada por enfermeiros na avaliação de indicadores clínicos e parâmetros biofisiológicos a partir da queixa principal, para identificar, adequadamente, a prioridade de atendimento dos pacientes, conforme os cinco níveis de classificações: vermelho (prioridade I), laranja (prioridade II) amarelo (prioridade III), verde (prioridade IV) e azul (prioridade V). O objetivo do estudo foi validar o Guia de ACCR em Pediatria na prática clínica. Estudo metodológico, desenvolvido em três etapas. Na primeira etapa realizou-se a revisão do conteúdo da 1ª versão do guia, por meio da análise de dois experts na temática. Na segunda etapa, avaliou-se a confiabilidade interobservadores da 2ª versão do guia entre a pesquisadora e duas enfermeiras (E1 e E2) treinadas pela pesquisadora com 206 crianças e/ou adolescentes, em junho de 2016, em um hospital municipal pediátrico de Fortaleza-CE. Na terceira etapa, realizou-se a aplicação da 2ª versão do guia na prática clínica com 400 participantes, exclusivamente pela pesquisadora, em julho e agosto de 2016, na referida instituição. Os dados foram analisados no SPSS 20.0, utilizando-se o índice Kappa com intervalo de confiança (IC) de 95% para análise da confiabilidade. Avaliou-se o efeito do uso do guia na prática clínica, por meio da associação entre a classificação de risco e as variáveis idades, sexo, peso, discriminador de risco, procedimentos realizados e destino após alta pelos testes Fisher-Freeman-Halton exact considerando estatísticamente significantes quando p<0,05 e a razão de verossimilhança com IC95%. As variáveis que apresentaram valores de p<0,20 ingressaram no modelo multivariado de regressão logística. Os resultados evidenciaram um guia revisado em seu conteúdo, estrutura e layout, válido e confiável. Houve concordância alta (Kappa=0,701) entre a pesquisadora e a E1 e quase perfeita (Kappa=0,847) com a E2, sendo p<0,001. Houve associação estatisticamente significante entre a classificação de risco e os discriminadores de risco (p=0,0001), realização de procedimentos na emergência (p<0,0001) e destino do paciente (p=0,0132). Verificou-se a prevalência do discriminador de risco alteração respiratória (207; 51,8%) no nível de prioridade IV (cor verde) (117; 56,5%). A razão de chance (RC) dos discriminadores de risco em ser mais urgente (laranja, amarelo e verde) em comparação ao não urgente (azul) variou de 1 a 12,3 vezes e o IC95% [1-82,7]. Dos 15 itens de maior urgência analisados no guia, mais da metade (8; 53,3%) obteve associação estatisticamente significante e 10 (66,7%) obtiveram RC>1, ou seja, tinham mais chances de serem classificados no nível de prioridade adequado. Concluiu-se que o Guia de ACCR em Pediatria é uma tecnologia em saúde confiável, válida e capaz de classificar o risco da criança em situações de emergência para estabelecer a ordem de prioridade de atendimento, visando minimizar erros de tomada de decisão do enfermeiro, possibilitando assistência humanizada e de qualidade.
|
98 |
Desenvolvimento de sistema para análise biomecânica da tarefa de digitação / Development system for biomechanics analysis to the typing taskGertz, Luiz Carlos January 1997 (has links)
O teclado QWERTY é a interface mais utilizada para inserir dados no computador e os profissionais desta área, programadores e digitadores, trabalham nele muitas horas por dia . Esta tarefa sedentária, repetitiva e estática é árdua e traz sérios problemas á saúde. A L.E.R. (Lesões por Esforços Repetitivos) é uma lesão associada à postura, à repetitividade, ao esforço fisico, ao conteúdo do trabalho, a fatores psicológicos e a características individuais. Este problema deve ser abordado por uma equipe de profissionais de áreas distintas: (a) um ergonomista, para corrigir o mobiliário, visando boa postura; (b) um engenheiro, para desenvolver equipamentos de estudo dos parâmetros envolvidos no trabalho (força, torque, ângulo, etc ... ); (c) um profissional da área de educação fisica; ( d) um psicólogo, entre outros profissionais. A L.E.R. é tão associada ao profissionais que utilizam o teclado que um de seus primeiros nomes foi "Doença dos Digitadores". O objetivo deste trabalho é desenvolver um sistema que permita que os profissionais da área da saúde, em conjunto com engenheiros, fisicos, matemáticos, e outros, o utilizem como uma ferramenta para estudar as causas da lesões adquiridas por digitadores, ou atestar a eficiência de soluções para o problema. Foram desenvolvidos estudos em Eletromiografia (foi aprimorado para esse trabalho o eletromiógrafo multicanal desenvolvido no LMM - Laboratório de Medições Mecânicas), Dinamometria (foi projetada e desenvolvida uma célula de carga para teclado) e Cinemetria (Lapex-ESEF) com a finalidade de estudar postura de trabalho, acessórios utilizados em digitação e determinação dos níveis das grandezas fisicas envolvidas no ato de acionar uma tecla. O sistema desenvolvido mostrou-se confiável e apresentou-se como uma boa ferramenta para auxiliar no estudo da LER. Alguns estudos tiveram a oportunidade de ser comparados com trabalhos desenvolvidos em outros países e mostraram que os resultados são confiáveis e, em alguns casos, apresentaram maior nível de informação (EMG, Dinamometria e Cinemetria) que os estudos internacionais mais recentes (que usam apenas duas destas técnicas: EMG e Dinamometria) . / The QWERTY is the most used interface to send information to the computer, and the professional workers related to typing, usually work many hours a day, sitting on a chair, in front o f a computer screen. This operation is hard, repetitive and static, leading to serious health problerns. T.C.I. (Trauma Cumulative Disorder) is an injury associated to posture, physical work, repetitiveness, psychological factors and individual characteristics. This kind of problem has to be analysed by a professional group, which includes: (a) an ergonomist, to realise changes in the furniture, (b) an engineer, to develop equipment for the study of the parameters related to this kind ofwork, (a) physical education teachers, and (d) a psychologist, among other professionals . TCI is so associated to typists that one of the first name was "typist desease". The objective of this work is to develop an experimental system that will allow to the professionals related to health, working together with engineers and other professionals, to study injuries caused by typing, or to evaluate the proposed solutions for the problem. The Electromyography (E.M.G.) system was improved at LMM (Mechanics Measurements Laboratory), using a multichannel EMG microcomputer assisted. In Dynamometry was developed a special load cell for the keyboard, and Cinemetry (Lapex-ESEF) studies were realised with the main objective to study the work posture and accessories, used in typing operation, and the calculation of physical parameters. The developed system is reliable and is a good tool to help the evaluation of C.T.I. problerns. Some of the experimental results were compared to those of intemational papers and showed a great similarity. Although, none o f these international works showed the use for these three techniques at the same time.
|
99 |
Aplicação do questionário EQ-5D em formato eletrônico : equivalência com a versão em português brasileiro do formato em papelBagattini, Ângela Maria January 2015 (has links)
Introdução: Entre os métodos de avaliação econômica em saúde, as avaliações de custo-utilidade ponderam custos e benefícios para comparar diferentes intervenções, utilizando como medida de desfecho índices de utilidade, que representam as preferências dos pacientes por determinados estados de saúde. O questionário de qualidade de vida EQ-5D gera este tipo de índice e foi criado para ser utilizado nas avaliações de custo-utilidade. Devido ao crescimento do uso de métodos eletrônicos para coleta e propagação de dados na área da saúde e pela facilidade de registro e manuseio dos dados em sistemas eletrônicos, o objetivo deste estudo foi verificar a equivalência de mensuração entre a versão em papel com a versão adaptada em tablet do questionário EQ-5D. Métodos: Foi realizado um estudo transversal com uma amostra composta por 509 indivíduos alfabetizados, com idade entre 18 e 64 anos, selecionados aleatoriamente da população geral das cidades de Porto Alegre e Belo Horizonte. Os sujeitos de pesquisa responderam ao questionário EQ-5D em dois momentos, com intervalo de no mínimo 24 horas e no máximo de 7 dias. Os participantes foram selecionados aleatoriamente em uma das tres amostras: uma com o grupo de teste re-teste, em que responderam nas duas ocasiões em meio eletrônico (tablet), e grupo crossover com uma amostra que respondeu papel e depois tablet e outra amostra que respondeu tablet e depois papel. Para avaliação da concordância dos métodos foi comparado os escores do EQ-5D e os valores da escala análogo visual (EAV) medidos por ambos os meios através do Coeficiente de Correlação Intra classe (CCI) e coeficiente Kappa. Resultados: Entre os entrevistados predominou o sexo feminino. Para o grupo crossover os resultados de concordância com CCI foram bastante satisfatórios, nos que responderam tablet-papel o CCI de 0,76 IC (0,58;0,89) no EQ-5D e 0,77 IC (0,68;0,84) na EAV e em papel- tablet o CCI foi de 0,75 IC (0,67;0,85) na EAV e 0,83 IC (0,75|0,89) no EQ-5D. Para o grupo teste re-teste (amostra tablet-tablet) CCI de 0,79 e intervalo de confiança IC (0,66;0,87), na EAV e no EQ-5D CCI de0,85 IC (0,73|0,91), e em com consistência interna semelhantes entre os métodos nos valores de utilidade e os valores da EAV. Conclusões: Os dois métodos de avaliação do EQ-5D são comparáveis e a aceitabilidade dos métodos é semelhante. / Background: Among the methods of economic evaluation in health, assessments of cost-utility are considering costs and benefits in order to compare different health interventions, through methods of assessing quality of life based on preferences, which are the result of utility scores that represent patient preference. The quality of life questionnaire EQ-5D is designed to be used in evaluations of cost-utility and is the most widely used and recommended in this type of analysis. Because of the growing use of electronic methods for collecting and propagation of information on health and ease of collection and handling of data in electronic systems, the aim of this study was to evaluate the measurement equivalence between the original paper version to version adapted tablet of EQ-5D questionnaire. Methods: Was conducted a cross-sectional study with a sample of 509 literates individuals aged 18-64 years were randomly from the general population of the cities of Porto Alegre and Belo Horizonte selected. Research subjects answered the questionnaire EQ-5D in two stages, with an interval of at least twenty four hours and a maximum of seven days to avoid the learning effect, carry-over. Participants were randomly selected to answer the test-retest group, which responded both times by electronic means (tablet) or were selected to answer the intersection group, cross over, which responded in the traditional method and also the electronic method, half group answered in the order paper / tablet and the other party in tablet / paper. To assess the concordance of the electronic method with the traditional means of the questionnaire compared the scores of the EQ-5D and the values of the visual analogue scale (VAS) through the Intra-class Correlation Coefficient (ICC). Results: Among respondents predominantly female. For the group crossover the results of agreement with ICC are satisfactory, who responded tablet-paper the ICC of 0.76 CI (0.58, 0.89) in the EQ-5D and 0.77 CI (0.68; 0.84) in the EAV and paper- tablet the ICC was 0.75 CI (0.67, 0.85) in the EAV and 0.83 CI (0.75 | 0.89) in the EQ-5D. For the test re-test group (tablet-tablet sample) ICC of 0.79 and confidence interval CI (0.66, 0.87) in VAS and EQ-5D CCI de0,85 IC (0.73 | 0.91), and with similar internal consistency between the methods in utility values and the values of VAS. Conclusions: The interviewed answers from the tablet and paper versions of the EQ-5D Quality of Life Questionnaire are comparable. The test-retest of the tablet version demonstrated reliability and both methods have high acceptability by the interviewed sample.
|
100 |
Segmentação dos vasos sanguíneos pulmonares em imagens de tomografia computadorizada do tórax / Lung blood vessels segmentation in thoracic CT ScansRibeiro, Alyson Bezerra Nogueira January 2013 (has links)
RIBEIRO, A. B. N. Segmentação dos vasos sanguíneos pulmonares em imagens de tomografia computadorizada do tórax. 2013. 79 f. Dissertação (Mestrado em Engenharia de Teleinformática) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2013. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2014-01-03T13:15:14Z
No. of bitstreams: 1
2013_dis_abnribeiro.pdf: 12330820 bytes, checksum: 37c185e13781545433d38e785dac92dc (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2014-01-09T13:26:21Z (GMT) No. of bitstreams: 1
2013_dis_abnribeiro.pdf: 12330820 bytes, checksum: 37c185e13781545433d38e785dac92dc (MD5) / Made available in DSpace on 2014-01-09T13:26:21Z (GMT). No. of bitstreams: 1
2013_dis_abnribeiro.pdf: 12330820 bytes, checksum: 37c185e13781545433d38e785dac92dc (MD5)
Previous issue date: 2013 / Medical image analysis using computer vision techniques has become quite promising because of its improvement on the diagnostic accuracy of various pathologies. For this reason, pulmonology became an area of high concentration of projects involving methods of Digital Image Processing. The blood vessels segmentation in the lung is an important aid in the detection of pulmonary heart diseases. This process is performed by analyzing the results obtained with known diagnostic imaging exams, like chest Xrays, computed tomography (CT) scan, magnetic resonance imaging, scintigraphy and angiography. Pulmonary hypertension and cancer are examples of diseases that can be diagnosed with less subjectivity if performing vessels segmentation, three-dimensional visualization and attribute extraction of these images. Thus, several algorithms are developed with the objective of obtaining an optimal segmentation of these structures. Among those algorithms are active contours, fuzzy logic, 3D Region Growing, 3D multi-scale ltering algorithm and Expectation Maximization (EM). In this study, the blood vessels were extracted from lung CT scans of the chest using three methods. The rst is a combination of 3D Region Growing controlled by a Gaussian membership function and thresholding, the second is a hybrid segmentation by thresholding and Fuzzy Connectedness. Finally,the third refers to segmentation using the K-means classi er. The results and evaluation of applying these algorithms are presented. / A análise de imagens médicas por meio de técnicas de visão computacional tornou-se bastante promissora, principalmente pelo fato de aperfeiçoar a acurácia diagnóstica de diversas patologias. Por essas razão, a Pneumologia é considerada atualmente uma área de concentração de projetos que envolvem métodos de Processamento Digital de Imagens. A segmentação de vasos sanguíneos pulmonares é de bastante auxílio na detecção de cardiopatias pulmonares. Esse processo é realizado através da análise dos resultados obtidos por exame de diagnóstico por imagem, os quais se destacam as radiogra fias torácicas, tomografi a computadorizada (TC) do tórax, ressonância magnética, cintilografi a pulmonar e angiogra fia. A hipertensão pulmonar e o câncer são exemplos de doenças que podem ser diagnosticadas com menor subjetividade ao realizar a segmentação de vasos, visualização em três dimensões e extração de seus atributos. Devido a essa importância, diversos algoritmos são desenvolvidos com intuito de obter uma segmentação ótima destas estruturas. Dentre estes, encontram-se os métodos por contornos ativos, Lógica Fuzzy, Crescimento de Regiões, Filtragem Multi-escalar 3D e algoritmo Expectation Maximization (EM). Nesta dissertação, são segmentados os vasos sanguíneos pulmonares de imagens de tomogra fia computadorizada do tórax utilizando-se três métodos: uma combinação de Crescimento de Regiões 3D controlado por uma função de pertinência gaussiana e limiarização; um método híbrido de segmentação por Conectividade Fuzzy e limiarização; por m, a segmentação utilizando o classi cador K-médias. Os resultados obtidos pelas segmentações são analisados e comparados por meio de uma análise dos coe cientes de similaridade e sensibilidade. Os resultados da aplicação dos três métodos são caracterizados aceitáveis e compatíveis com os observados na literatura.
|
Page generated in 0.0622 seconds