• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 301
  • 56
  • 10
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 425
  • 425
  • 230
  • 136
  • 95
  • 94
  • 92
  • 84
  • 78
  • 75
  • 71
  • 71
  • 71
  • 62
  • 51
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Avaliação da resisténcia de união e caracterização da camada híbrida formada por adesivos experimentais a base de metacrilato hidrófobo ou solvatado em 10% e 30% de etanol, aplicados sobre dentina saturada com etanol em um estudo de longevi / Evaluation of bond strength and characterization of hybrid layer produced by an experimental adhesive based on hydrophobic methacrylate or dissolved in 10% and 30% ethanol, applied to ethanol-saturated dentin in a longevity study

Andre Guaraci De Vito de Moraes 20 May 2009 (has links)
A longevidade da interface adesiva é afetada pelos efeitos da degradação hidrolítica, cuja ocorrência está associada ao alto conteúdo de água presente no tecido dentinário. A hibridização da dentina com monômeros hidrófobos em um substrato isento de água poderia fazer com que a resistência de união dessas interfaces se mantivesse estável por um período de tempo prolongado. O objetivo deste estudo foi avaliar a resistência de união, através do teste de microtração, da interface adesiva em dentina saturada com etanol, sobre a qual se fez o uso de um adesivo hidrófobo, além de caracterizar a morfologia desta interface. Vinte e oito dentes molares foram cortados para que um flat de dentina do terço médio fosse obtido. Foram estudados quatro grupos experimentais: Grupo controle (Scotchbond MultiUso, 3M ESPE), cuja dentina foi saturada com água, grupo experimental 1, cuja dentina saturada com etanol foi hibridizada com o adesivo hidrófobo puro do sistema Scotchbond e grupos experimentais 2 e 3, cuja dentina saturada com etanol recebeu primers hidrofóbicos dissolvidos em etanol 10% e 30% respectivamente. Após a hibridização da dentina, os dentes foram restaurados de forma incremental com resina composta (Filtek Z350, 3M ESPE). As resistências adesivas imediata (24 horas) e tardia (6 meses) foram avaliadas por -tração (0.5 mm/min) de palitos obtidos por cortes perpendiculares à interface adesiva, com área de seção transversal de 1 mm2. O meio de armazenagem dos palitos foi saliva artificial a 37°C. Amostras dos palitos foram preparadas para caracterização da interface adesiva e avaliação do modo de fratura em microscopia eletrônica de varredura. Os dados foram submetidos à análise de variância de dois fatores, Técnica Adesiva e Tempo de Armazenamento, sendo este último vinculado. Os resultados encontrados não mostraram diferença estatística para todos os grupos estudados após 6 meses de armazenamento quando comparados com os dados obtidos de forma imediata (24 horas). Também não foram encontradas diferenças entre os grupos quando avaliados em 24 horas e em 6 meses separadamente. A camada híbrida formada em dentina saturada por etanol apresentou características similares, em relação à morfologia e dimensão, àquela formada pela técnica convencional. A técnica de substituição de água por etanol produziu interfaces tão resistentes quanto à técnica úmida convencional, pelo menos nos primeiros seis meses. / The longevity of an adhesive interface is affected by the effects of hydrolytic degradation, which is associated with high water content in the dentin tissue. The hybridization of dentin with hydrophobic monomers in a water-free substrate could make the bond strength of these interfaces remain stable for an extended period of time. The aim of this study was to evaluate the bond strength of the adhesive interface in ethanol-saturated dentin using a microtensile test, on which a hydrophobic adhesive was used, and also to characterize the morphology of this interface. Twenty-eight molar teeth were cut to a flat middle third of the dentin was obtained. We studied four experimental groups: control group (Scotchbond MultiPurpose, 3M ESPE), whose dentin was saturated with water; experimental group 1, whose dentin saturated with ethanol was hybridized with the pure hydrophobic adhesive from Scotchbond adhesive system and experimental groups 2 and 3, whose dentin saturated with ethanol received hydrophobic primers dissolved in ethanol 10% and 30%, respectively. After dentin hybridization, teeth were restored with the incremental technique with composite resin (Filtek Z350, 3M ESPE). The immediate (24 hours) and late (6 months) adhesive resistance was determined by - tensile (0.5 mm / min) of \"sticks\" obtained by perpendicular cuts on the adhesive interface, with cross section area of 1 mm2. The sticks storage medium was artificial saliva at 37 °C. Interface samples were prepared to characterize the adhesive interface and to assess the failure mode by scanning electron microscopy. The data were submitted to two factors analysis of variance, adhesive technique and storage time, the latter being dependent. The results showed no statistical differences for all groups after 6 months of storage when compared to data obtained from the immediate group (24 hours). Also, no differences were found between groups evaluated at 24 hours and 6 months separately. The hybrid layer formed in ethanolsaturated dentin had similar characteristics considering the morphology and size formed by conventional technique. The technique of water replacement for ethanol produced interfaces as strong as the conventional wet technique, at least in the first six months.
252

Emprego de agentes retardadores em substituição aos desmoldantes convencionais na moldagem de concreto para recebimento do revestimento de argamassas. / Use of retarding agents as a substitute for conventional release agents in concrete moulding for the application of rendering mortar.

Mirella Pennacchi Assali 09 October 2012 (has links)
As estruturas de concreto são moldadas em formas tratadas com desmoldantes e sua presença dificulta a adesão da argamassa fresca, com posterior descolamento no estado endurecido. Este estudo tem por objetivo explorar o potencial de uso de agentes retardadores em substituição aos desmoldantes convencionais na moldagem de concreto para obtenção de superfícies com maior capacidade de ancoragem das argamassas. A viabilidade do uso de agentes retardadores foi verificada determinando-se de modo comparativo a resistência de aderência à tração da argamassa e do chapisco aplicados sobre corpos de prova de concreto moldados em formas de madeira plastificada tratadas com agente retardador e com desmoldante convencional. O ensaio de aderência mostrou que a utilização de agentes retardadores possibilita maior facilidade para a remoção da camada superficial do concreto, resultando em aumento de rugosidade e absorção superficial, permitindo maior resistência de aderência da argamassa e chapisco. Posteriormente, foram coletados agentes retardadores do mercado e avaliados: desempenho na aplicação sobre as formas, impacto dos produtos na saúde do trabalhador e no meio ambiente, e o efeito retardador na hidratação do cimento. Também foram avaliados quanto: a aplicabilidade dos produtos e sua influência no preparo da superfície para o recebimento da argamassa quando tratadas com produtos retardadores e convencionais em três tipos de formas. O estudo mostrou que o uso de agente retardador pode ser uma técnica viável para reduzir os problemas de descolamento do revestimento aplicado sobre superfícies de concreto. Através dos ensaios específicos desenvolvidos e adaptados para esta pesquisa, foi possível identificar que existem diferenças de comportamentos entre os produtos, sendo eles convencionais ou retardadores, e que os tipos de forma influenciam nestes comportamentos. Foi verificado também que as formas mais simples e com custos menores podem ser mais apropriadas para utilização destes produtos. / The concrete structures are cast in molds treated with a release agent (demolding product), and its presence hinders the mortars initial adhesion in the plastic state, as well as the bond strength after hardening. The study aims is to explore the potential use of retarding agents to replace conventional release agents in the concrete formwork. The technical viability of using a retarding agent was verified by comparing the tensile bond strength of rendering mortars applied on concrete surfaces cast with a conventional release agent and on concrete surfaces cast with a retarding release agent. The results showed that, through the use of retarding products, the removal of the concrete surface layer was possible by increasing the surface roughness, the surface water absorption and the tensile bond strength of the mortar to this concrete. Performance tests were also done with retarding products commercially available in the Brazilian market to verify the behavior of such products during application on molds, their impact on workers health and on the environment, and the retarding effect in cement hydration. It was also evaluated the applicability of these products and their influence on surface preparation to receive mortar when treated with retarding and conventional products, in three types of molds. Retarding products showed to be a viable technique for reducing the detachment problems of rendering mortars applied on concrete surfaces. Through the specific tests developed and adapted for this study, it was observed that there are differences in behavior between the conventional or retarding products, and also observed how these types of molds can influence the performance of the products. It was also observed that the simplest molds with lower cost can be more suitable in this application.
253

Tratamento térmico em bases de bráquetes monocristalinos silicatizados e silanizados: efeito na adesão ao esmalte

Silva, Emília Adriane 15 September 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-13T13:59:40Z No. of bitstreams: 1 emiliaadrianesilva.pdf: 2213397 bytes, checksum: 9d1b10517697f8e5f79ea9e57c98368a (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T16:55:53Z (GMT) No. of bitstreams: 1 emiliaadrianesilva.pdf: 2213397 bytes, checksum: 9d1b10517697f8e5f79ea9e57c98368a (MD5) / Made available in DSpace on 2016-07-13T16:55:53Z (GMT). No. of bitstreams: 1 emiliaadrianesilva.pdf: 2213397 bytes, checksum: 9d1b10517697f8e5f79ea9e57c98368a (MD5) Previous issue date: 2011-09-15 / O objetivo deste trabalho foi avaliar o efeito do tratamento térmico na adesão de bráquetes monocristalinos silanizados após processo de silicatização. O estudo foi autorizado pelo comitê de ética da Universidade Federal de Juiz de Fora, parecer número 161/2010. Sessenta bráquetes de alumina monocristalina (Pure®, Orthotechnology, Tampa, FL, EUA) e sessenta dentes pré-molares superiores recém extraídos com finalidade ortodôntica foram randomicamente divididos em três grupos (n=20) de acordo com a estratégia de tratamento das superfícies adesivas: G1- sem tratamento (grupo controle); G2- jateamento com partículas de alumina revestidas por sílica-30 µm Cojet (3M ESPE, Irvine, CA, EUA) + aplicação do silano Monobond S (Ivoclar Vivadent, Shaan, Liechtenstein); e G3- jateamento com Cojet seguido de silanização e tratamento térmico da superfície com jato de ar (Secador Taiff Compacto Turbo, 6000W, São Paulo, SP) à 100ºC±1, a 1 cm por 60 s. Após os tratamentos de superfície, os bráquetes foram colados aos dentes com o adesivo ortodôntico Transbond XT Light Cure Adhesive (3M ESPE, Irvine, CA, EUA). Os espécimes foram armazenados em estufa com água destilada a 37ºC por 100 dias. Durante este período, metade dos espécimes de cada grupo foi submetida à termociclagem (-T) (6000 ciclos, 5ºC±1 e 55ºC±1) com banhos alternados de 30 s. Com o auxílio de uma máquina universal para ensaios mecânicos (EMIC - DL 1000, São José dos Pinhais, Paraná, Brasil – F.O. Unesp, São José dos Campos, SP) e um dispositivo tipo faca, os grupos foram submetidos ao ensaio de resistência adesiva ao cisalhamento (1mm/min) até que ocorresse o descolamento dos bráquetes. As superfícies fraturadas foram observadas sob microscopia óptica (30×) para categorização dos tipos de falha e determinação do índice de remanescente adesivo (IRA). Doze amostras representativas (n=2) foram também observadas em microscopia eletrônica de varredura. Os resultados foram submetidos à análise estatística ANOVA (2-fatores) e as médias foram comparadas pelo teste de Tukey com nível de significância em 5% para ambos os testes. Para os resultados de resistência adesiva, o teste ANOVA revelou significância estatística para a interação dos fatores tratamento de superfície e termociclagem (p= 0,013) e para o tratamento de superfície (p= 0,0). O fator termociclagem não influenciou estatisticamente os resultados (p = 0,6974). As maiores e menores médias de resistência adesiva com o desvio padrão foram encontradas respectivamente em G3-T (27,59 ± 6,4 MPa) e G2-T (8,45 ± 6,7 MPa). Na análise da superfície após o ensaio, foi constatada a fratura de esmalte e/ou dentina em dezesseis espécimes. Com exceção do grupo G2, todos os outros apresentaram fratura de estrutura dentária. O modo de falha tipo misto e IRA = 1 (49,12%) foram os mais frequentes. Conclui-se que o tratamento térmico das superfícies silanizadas após o jateamento com partículas de alumina revestidas por sílica produziu valores de resistência adesiva similares aos valores encontrados no grupo controle. / The objective of this study was to evaluate the effect of heat treatment on bond strength of monocrystalline brackets silica coating and silanization process. The study was approved by the ethics committee of the Federal University of Juiz de Fora, autorization number 161/2010. Sixty brackets monocrystalline alumina (Pure®, OrthoTechnology, Tampa, FL, EUA) and sixty premolars recently extracted for orthodontic were randomly, divided in three groups (n=20) according to the strategy of treating surfaces adhesive: G1 – no treatment (control group), G2 – blasting with alumina particles coated with silica 30 µm Cojet (3M ESPE/ Irvine, CA, EUA) + application of silane Monobond S (Ivoclar Vivadent, Shaan, Liechtenstein), and G3 – blasting (Cojet) + silanization + heat treatment with a hairdryer (Taiff Compact Turbo Dryer, 6000W, São Paulo, SP) to 100ºC ± 1, to 1 cm, for 60 s. After surface treatments, the brackets were bonded to teeth with orthodontic adhesive Transbond XT Light Cure Adhesive (3M ESPE, Irvine, CA, EUA). The specimens were stored in distilled water for 100 days. During this period, half of the specimens of each group was subjected to thermocycling (-T) (6000 cycles, 5ºC ± 1ºC and 55ºC ± 1) with baths of 30 seconds. With the support of a universal mechanical testing machine (EMIC – DL 1000, Pinhais, Paraná, Brazil – FO/UNESP, São José dos Campos, SP) an device like a knife, the groups were submitted a shear bond strength test (1mm/min) until failure. The fractured surfaces were observed under debonded specimen surfaces were examined with a stereomicroscope (30×) to classify the types of failure and determine the adhesive remnant index (ARI). Twelve representative samples (n=2) were also observed in scanning electron microscopy. The results were statically analyzed using ANOVA (two-way) and means were compared by Tukey test with significance level of 5% for both tests. For the results of bond strength, the ANOVA revealed statistical significance for the interaction of surface treatment and thermocycling (p= 0,013) and the surface treatment (p= 0,0). The factor thermocycling did not influence the results statistically (p= 0,6974). The highest and lowest mean bond strength including the standard deviation were found in G3T (27,59 ± 6,4 MPa) and G2T (8,45 ± 6,7MPa). In the analysis of the surface after test was found sixteen specimens with enamel/dentin fracture. Except for G2, all others groups had fractured tooth structure. The failure mode mixed and IRA=1 (49,12%) were the most frequent. The heat treatment of the silanized surfaces after blasting with alumina particles coated with silica produced bond strength values similar to those found in the control group.
254

Caracterização e propriedades mecânicas de uma resina microhíbrida e de uma nanoparticulada e avaliação da resistência de união em reparo por microtração / Characterisation and mechanical properties a microhybrid composite and a nanoparticulate and evaluation of bond strength in repair by microtensile

Rodrigues Junior, Sinval Adalberto 07 January 2008 (has links)
Made available in DSpace on 2014-08-20T14:30:06Z (GMT). No. of bitstreams: 1 tese_sinval_adalberto_rodrigues_junior.pdf: 7739591 bytes, checksum: ba6e2226913bf441bd344df7d625d1a0 (MD5) Previous issue date: 2008-01-07 / Repairing composite restorations instead of replacing them became possible with the development of adhesion. Nevertheless, a considerable number of Schools of Dentistry still refuses to consider the repair as a feseable procedure, mainly due to the lack of cientific evidence supporting it. Factors related to the composites, such as their microstructure and composition, are determining of their clinical performance, since they determine the composite s physical and mechanical properties. Likewise, they also influence the quality of the surface treatment of the aged composites in repair situations. Thus, this study aimed to characterize two commercial composites a microhybrid (Filtek Z250TM 3M/ESPE Z2) and a nanofill composite (Filtek SupremeTM 3M/ESPE SU) and test the influence of their microstructural and compositional characteristics on the bond strength to a repair composite with different surface treatments. The characterization of the composites microstructure and composition was performed through scanning electron microscopy (SEM) and electron dispersive spectroscopy (EDS). Several properties were determined: filler weight percentage (wt%), flexural strength (sf), Weibull modulus (m), characteristic strength (s0), fracture toughness (KIc), hardness (H), degree of conversion (DC) and dynamic elastic modulus (E). The critical defects (c) resulting from the flexural strength test were identified, characterized and measured. The repair bond strength (s) was tensile tested after the aging of the composites. The surfaces of the aged composites were conditioned with hydrofluoric acid (HA), bur abrasion (AB), sandblasting with aluminum oxide particles (AO) and silica coating (SC), and treated with silane (SI), adhesive system (SB) or the association of both (SI+SB). The fracture behavior (represented by sf and KIc) and the structural reliability (represented by m and s0) were similar for both composites. Z2 presented higher wt%, H and E than SU. The DC was similar in the top surface of the specimen. However, the DC of SU decreased at 2-mm depth. The s was affected by both, the type of composite and the surface treatment. Z2 presented higher repair s than SU. The surface treatments based on the sanblasting of particles (AO and SC) produced higher s, independent of the primer used. HA produced the lowest s values, and should be avoided in repair situations. The repair of composite restorations is dependent upon the microstructure and the composition of the composite and might be performed sandblasting the surface either with aluminum oxide particles or silica oxide particles associated to a primer. / O reparo de restaurações de resina composta como alternativa à substituição das mesmas foi possível a partir do desenvolvimento da adesão. Entretanto, um grande número de Escolas de Odontologia ainda se recusa a considerá-lo como procedimento factível, principalmente devido à escassez de evidência científica acerca do assunto. Fatores relativos às resinas compostas, como sua microestrutura e composição, são fundamentais na determinação de seu desempenho clínico, já que determinam suas propriedades físicas e mecânicas. Da mesma forma, tais fatores influenciam a qualidade do tratamento de superfície realizado em resinas compostas envelhecidas para reparo das restaurações. Assim, este estudo visou caracterizar duas resinas compostas disponíveis comercialmente, uma microhíbrida (Filtek Z250TM 3M/ESPE Z2) e uma nanoparticulada (Filtek SupremeTM 3M/ESPE SU) e testar a influência de suas características microestruturais e composicionais na resistência de união a uma resina de reparo com tratamentos de superfície diferentes. A caracterização da microestrutura e composição foi realizada através de microscopia eletrônica de varredura (MEV) e espectroscopia dispersiva de elétrons (EDS). Várias propriedades foram determinadas: percentual de carga em massa (wt%), resistência à flexão (sf), módulo de Weibull (m), resistência característica (s0), tenacidade de fratura (KIc), dureza (H), grau de conversão (GC) e módulo de elasticidade dinâmico (E). Os defeitos críticos (c) resultantes das fraturas do teste de flexão foram identificados, caracterizados e mensurados. A resistência de união em reparo (s) foi realizada após o envelhecimento das resinas, através do teste de microtração. As superfícies das resinas compostas envelhecidas foram condicionadas com ácido hidrofluorídrico (HA), abrasão com broca (AB), jateamento com óxido de alumínio (AO) e silicatização (silica coating SC), e tratadas com silano (SI), sistema adesivo (SB) ou a associação de ambos (SI+SB). O comportamento de fratura (representado pela (sf), e pela Kic) e a 10 confiabilidade estrutural (representada por m e s0) dos materiais foi similar. A Z2 apresentou maior wt%, H e E que a SU. O GC foi similar na superfície superior dos cp, porém na inferior (a 2mm de profundidade) o GC da SU foi significativamente menor. A s foi afetada tanto pelo tipo de resina composta quanto pelos tratamentos de superfície. A Z2 apresentou s maior que a SU em reparo. Os tratamentos de superfície baseados no jateamento de partículas (AO e SC) produziram os maiores valores de s, independente do primer utilizado. O HA produziu os menores valores de s, devendo ser evitado em situações de reparo. O reparo de restaurações de resina composta é dependente da microestrutura e da composição da resina a ser reparada e pode ser efetuado através das técnicas envolvendo o jateamento de partículas associadas a um primer
255

Tetrahidrofurano como solvente de adesivos odontológicos / Tetrahydrofuran as solvent in dental adhesive systems

Fontes, Silvia Terra 27 February 2009 (has links)
Made available in DSpace on 2014-08-20T14:30:16Z (GMT). No. of bitstreams: 1 Dissertacao_ Terra_Silvia_ Fontes.pdf: 826039 bytes, checksum: 1168fd40390593dc923413d4c46c356d (MD5) Previous issue date: 2009-02-27 / The aim of this study is to evaluate the performance of tetrahydrofuran (THF) as solvent in the primer composition of an experimental adhesive system on the resin-dentin microtensile bond strength after 24h and 6 months of water storage. Sixty bovine incisors will be randomly separated into ten groups, according to the solvent type: 1) THF, 2) acetone, 3) ethanol, 4) water, 5) THF/water, 6)acetone/water, 7) ethanol/water, 8) All Bond 2 (acetone/ethanol/water), 9) Opti Bond FL (ethanol/water) e 10) Scotch Bond (water). Vestibular enamel will be removed to, expose the superficial dentin and further polished with grit silicon-carbide under irrigation. After acid etching with 35% phosphoric acid (15s), the surfaces will be rinsed with water (30s) and the excess of superficial water will be removed with absorbent paper. Each experimental primer will be applied with agitation (30s) followed by a gently air stream (10s) at a distance of 10cm to help solvent evaporation. One coat of an experimental adhesive resin will be applied and lightactivated (20s). The marketed available adhesive systems will be used according manufacturer instructions. Resin composite restorations will be constructed incrementally. Each layer of composite will be light-activated individually at 1400mW/cm2. After water storage for 24h at 37oC, the restored teeth will be sectioned to obtain sticks with a cross-sectional area of approximately 0.5mm2. Half of specimens will be tested after 24 hours and the other half will be maintained in the same storage conditions to be evaluated after 6 months. Microtensile bond strength (MPa) will be evaluated with an universal testing machine (1.0mm/min/100N). The half corresponding to dentin will be evaluated in a light microscope (500X) and classified as: CD) cohesive in dentin, CC) cohesive in resin composite, A) adhesive, M) mixed or PD) premature debonded. Statistical significance will be set at α=0.05 / O objetivo deste estudo será avaliar o desempenho do tetrahidrofurano (THF) como solvente na composição do primer de um adesivo odontológico experimental através da resistência de união à microtração em dentina após 24h e 6 meses de armazenamento em água. Sessenta incisivos bovinos serão distribuídos aleatoriamente em dez grupos, conforme o tipo de solvente: 1) THF, 2) acetona, 3) etanol, 4) água, 5) THF/água, 6) acetona/água, 7) etanol/água, 8) All Bond 2 (acetona/etanol/água), 9) Opti Bond FL (etanol/água) e 10) Scotch Bond (água). O desgaste na face vestibular dos dentes será realizado até exposição da dentina superficial com lixas de carbeto de silício sob refrigeração. Depois que a superfície dentinária for condicionada com gel de ácido fosfórico a 35% (15s) e lavada com água (30s), o excesso de água superficial será removido com papel absorvente. Nos grupos experimentais, o primer será aplicado sob agitação constante (30s) seguido de jato de ar por (10s) a distância de 10cm, a fim de auxiliar a evaporação do solvente. Uma camada de resina adesiva experimental será aplicada e fotoativada (20s). Os sistemas adesivos de marcas comerciais serão aplicados conforme instruções dos fabricantes. As restaurações serão realizadas com compósito restaurador pela técnica incremental. Os incrementos serão fotoativados individualmente a 1400mW/cm2. Após o período de 24 horas de armazenamento em água a 37ºC, as amostras serão seccionadas obtendo-se uma área de secção transversal de aproximadamente 0,5mm2. Metade dos corpos de prova será testada imediatamente e a outra metade será mantida sob as mesmas condições de armazenamento para avaliação após 6 meses.A resistência de união à microtração (MPa) será testada através de uma máquina universal de ensaios mecânicos (1,0mm/min/100N). As porções correspondentes à dentina serão analisadas por microscopia de luz (500X) e classificadas de acordo com o padrão de fratura em: CD) falhas coesivas em dentina, CC) falhas coesivas em compósito restaurador, A) falhas adesivas, M) falhas mistas ou FP) falhas prematuras. Significância estatística será considerada quando α=0.05
256

ADESÃO ÀCERÂMICA Y-TZP: ESTUDO DA DEPOSIÇÃO DE NANOFILMES À BASE DE SÍLICA NA SUPERFÍCIE DA Y-TZP / ADHESION TO THE Y-TZP CERAMIC: STUDY OF SILICA NANO-FILM COATING ON THE YTZ-P SURFACE

Druck, Carolina Ceolin 15 August 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This study in vitro proposed to evaluate the influence of silica-based film coated on the Y-TZP surface on the durability bond strength (BS) between ceramic and resin cement. Eighty Y-TZP blocks (5x5x4 mm) were obtained, included in acrylic resin and were divided into four groups according to the surface treatments treatments (n=20): (TBS) tribochemical silica coating (Cojet, 3M/ESPE), (F-5) 5 nm SiO2 nanofilm and silanization, (F-500) 500 nm SiO2 nanofilm and silanization, and (F-500HF) 500 nm SiO2 nanofilm + HF + silanization. Specimen of composite resin were made with a metal matrix and cemented with resin cement (Relyx ARC) to Y-TZP blocks. Half of the specimens (n=10) of each treatment was tested 24 hours after adhesion (dry), and another half (n=10) will be subjected to the aging (storage for 90 days and 103 thermal cycles). The specimens were submitted to shear test (1min/min). After debonding, the surfaces will be analyzed by optical microscopy and scanning electron microscopy (SEM) to categorize the failure modes and the micro morphology of treated surfaces. Additional analyzes were made in X-ray dispersive energy analysis (EDS). Data were statistically analyzed for Kruskal-Wallis/Mann Whitney (α=0,05) tests. The surface treatment showed significant differences in conditions D (p=0.0001) and A (p=0.0000). In both test conditions , TBS and F-5 promoted the highest bond strength, significantly. Means (SD) for BS data (MPa) were: TBS/D: 10.2 (5.1)AB; F-5/D: 12.0 (3.9)A; F-500/D: 14.9 (4.7)A; F-500HF/D: 4.1 (5.6)B; TBS/A: 9.1 (4.4)a; F-5/A: 7.8 (5.3)a; F-500/A: 0.01 (0.0)b; F-500HF/A: 1.4 (2.3)b. The adhesion to zirconia can be improved if the surface receives a 5 nm layer of SiO2 nanofilm or is subjected to sandblasting with silica particles, followed by silanization. / O presente trabalho avaliou, in vitro, a influência da deposição de filmes à base de sílica sobre a superfície da Y-TZP na durabilidade da resistência de união entre essa cerâmica e um cimento resinoso. Foram confeccionados oitenta blocos (5x5x4 mm) de Y-TZP, estes foram incluídos em resina acrílica e divididos em 4 grupos de acordo com o tratamento de superfície (n=20): (TBS) tratamento triboquímico (Cojet, 3M/ESPE); (F-5) filme de SiO2 de 5 nm e silanização; (F-500) filme de SiO2 de 500 nm e silanização; (F-500HF) filme de SiO2 de 500 nm + HF + silanização. Sobre os blocos de Y-TZP foram cimentados (RelyX ARC) cilindros feitos com resina composta confeccionados com uma matriz metálica. Metade dos espécimes (n=10) de cada grupo foi testada após 24h de cimentação (S- sem envelhecimento) e a outra metade (n=10) foi submetida ao envelhecimento (TC, armazenagem por 90 dias e 103 ciclos térmicos). Então, os espécimes foram submetidos ao teste de cisalhamento (1min/min). Após o teste, as superfícies foram analisadas por Microscópio Óptico e MEV para categorizar o modo de falha. Também foram feitas análises adicionais em EDS. Os dados foram analisados estatisticamente pelo teste de Kruskal-Wallis/Mann Whitney (α=0,05). A resistência adesiva foi influencida pelo tipo de tratamento de superfície, nas condições S (p=0.0001) e TC (p=0.0000). Em ambas condições de armazenagem, os tratamentos TBS e F-5 promoveram mais alta resistência adesiva, significativamente. Médias (DP) de RU (MPa) foram: TBS/S: 10,2(5,1)AB; F-5/S: 12,0(3,9)A; F-500/S: 14,9(4,7)A; F-500HF/S: 4,1(5,6)B; TBS/TC: 9,1(4,4)a; F-5/TC: 7,8(5,3)a; F-500/TC: 0,01(0,0)b; F-500HF/TC: 1,4(2,3)b. Concluiu-se que a adesão a zircônia pode ser potencializada se a superfície receber a deposição do filme de SiO2 de 5 nm ou for submetida a jateamento com partículas de sílica, seguida de silanização.
257

AVALIAÇÃO DA EVAPORAÇÃO DO SOLVENTE DE SISTEMAS ADESIVOS CONTEMPORÂNEOS / ASSESSMENT OF SOLVENT EVAPORATION OF CONTEMPORARY ADHESIVES SYSTEM

Werle, Stefanie Bressan 09 March 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Objectives: The aim of this study was to evaluate the effect of air-drying time on degree of evaporation of solvent (DE), microtensile resin-dentin bond strength (μTBS) and degree of conversion (DC) of adhesive systems. Methods: Four two-steps etch-and-rinse (Adper Single Bond 2, XP Bond, Prime & Bond 2.1 and Opti Bond Solo) and one one-step self-etch (Adper Easy One) were tested. The DE was measured gravimetrically (n=6) after 3, 5, 10, 20, 30 and 60 seconds by air-drying. For μTBS flat dentin surfaces were obtained from fifty caries-free extracted molars (n=5). The adhesive systems were applied to dentin surfaces according to the manufacturer s instructions and subsequently air-drying for the time proposed by manufacturer (A) or for prolonged time (B), corresponding to maximum DE in the times evaluated. A composite resin was used for coronal build-up. After 24h water storage at 37ºC, the specimens were sectioned in x and y directions to obtain bonded sticks (0.9 mm2) which were immediately subjected to μTBS (1mm/min). The DC (n=3) was calculated by Fourier-transform infrared spectroscopy with attenuated total reflectance considering air-drying times A and B. The data of DE were statistically analyzed by ANOVA and Tukey´s test, μTBS and DC were analyzed by T-Test (α = 0.05). Results: The prolonged time (B) increased the DE for all materials compared to manufacturer´s times, however improved μTBS only for XP Bond and Adper Easy One. DC was not affected by evaluated air-drying times. There was no significant correlation between DC and μTBS. Conclusion: The evaporation of solvent from adhesive systems is affected by air-drying. The effect of air-drying time seems be material-dependent on parameters evaluated. Changes in protocols of use may be necessary to obtain better properties. / Objetivos: Avaliar o efeito de diferentes protocolos de aplicação de jato de ar no grau de evaporação do solvente (GE), resistência de união à dentina (RU) e grau de conversão (GC) de sistemas adesivos. Métodos: Quatro sistemas adesivos de dois passos com condicionamento ácido prévio (Adper Single Bond 2, XP Bond, Prime & Bond 2.1 e Opti Bond Solo) e um autocondicionante de passo único (Adper Easy One) foram testados. O GE foi mensurado gravimetricamente (n=6) após a aplicação de jato de ar durante 3, 5, 10, 20, 30 e 60 segundos. A RU à dentina foi mensurada através do teste de microtração. Para isso, cinquenta molares humanos hígidos (n=5) tiveram o esmalte e dentina superficial removidos. Os sistemas adesivos foram aplicados de acordo com as instruções dos fabricantes na superfície dentinária e subsequentemente foi aplicado jato de ar durante o tempo proposto pelo fabricante (A) ou por tempo prolongado (B), o qual resultou em evaporação máxima nos tempos considerados na avaliação do GE. Após a confecção de blocos de resina composta e armazenamento em água à 37ºC, por 24 horas, os espécimes foram seccionados em dois eixos a fim de obterem-se espécimes com área de secção transversal de aproximadamente 0,9 mm2. Os espécimes foram submetidos ao teste de microtração com velocidade de 1mm/min. O GC (n=3) foi analisado por espectroscopia de infravermelho transformada de Fourier (FTIR) considerando os tempos A e B. Os dados do GE foram submetidos à análise de variância de um fator e teste de Tukey. Os dados de RU e GC foram submetidos ao teste t de Student pareado. Todas as análises foram realizadas considerando o nível de significância de 5%. Resultados: A aplicação de jato de ar por tempo prolongado (B) aumentou o GE para todos os materiais em comparação ao tempo proposto pelo fabricante. Contudo, maiores valores de RU foram obtidos somente para os sistemas XP Bond e Adper Easy One. O GC não foi afetado pelos tempos de aplicação de jato de ar avaliados. Não houve correlação significante entre GC e RU. Conclusão: A evaporação do solvente dos sistemas adesivos testados é modulada pelo tempo de aplicação de jato de ar. A influência do tempo de aplicação do jato de ar nos parâmetros testados parece ser material dependente. Mudanças no protocolo de aplicação jato de ar podem ser necessárias a fim de se obterem as melhores propriedades dos sistemas adesivos.
258

EFEITOS DO PRÉ-TRATAMENTO DENTINÁRIO E TEMPERATURA DO ADESIVO NA RESISTÊNCIA ADESIVA DE UM SISTEMA ADESIVO UNIVERSAL / EFFECTS OF DENTIN PRETREATMENT AND ADHESIVE TEMPERATURE ON BOND STRENGTH OF A UNIVERSAL ADHESIVE SYSTEM

Sutil, Bruna Gabrielle da Silva 28 July 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This study aimed to evaluate the effects of dentin pretreatment and temperature on the bond strength of a universal adhesive system to dentin. Ninety-six extracted non-carious human third molars were randomly divided into 12 groups (n=8) according to Scotchbond Universal Adhesive (SbU) applied in self-etch (SE) and total-etch (TE) mode, adhesive temperature (20ºC or 37ºC) and sodium bicarbonate or aluminum oxide air abrasion. After composite build up, bonded sticks with cross-sectional area of 1 mm² were obtained to evaluate the microtensile bond strength (μTBS). The specimens were tested at a crosshead speed of 0.5 mm/min on a universal testing machine until failure. Fractured specimens were analyzed under stereomicroscope to determine the failure patterns in adhesive, cohesive (dentin or resin) and mixed fractures. The microtensile bond strength data was analyzed using to two-way ANOVA and Tukey s test (p<0.01). Interaction between treatment and temperature was statistically significant to SbU applied in SE technique. Both dentin treatments showed higher bond strength to TE mode, regardless of adhesive temperature. When compared to control group, sodium bicarbonate increased bond strength of SbU in SE mode. Adhesive temperature did not significantly affect the μTBS of tested groups. Predominantly, adhesive failure was observed for all groups. Thus, the dentin pretreatment may be an alternative to improve the adhesive properties of the Scotchbond Universal adhesive system. / O presente estudo avaliou os efeitos do jateamento de partículas abrasivas e da temperatura sobre a resistência adesiva de um sistema adesivo universal à dentina. Utilizou-se 96 terceiros molares humanos hígidos e extraídos, divididos aleatoriamente em 12 grupos (n=8) de acordo com o adesivo Scotchbond Universal (SBU) aplicado no modo autocondicionante (SE) ou condicionamento ácido total (TE), temperatura do adesivo (20ºC ou 37ºC) e jateamento da dentina com partículas de óxido de alumínio ou bicarbonato de sódio. Após a realização das restaurações, foram obtidos espécimes em forma de palito com área seccional de 1 mm² para avaliar a resistência adesiva através do teste de microtração. O teste foi realizado em uma máquina de ensaio universal, a uma velocidade de 0,5 mm/min até a fratura ocorrer. As fraturas foram analisadas sob estereomicroscopia para classificar as falhas em adesiva, coesiva (resina ou dentina) e mista. Os dados foram submetidos ao teste ANOVA a dois fatores e ao teste de Tukey. A interação entre tratamento e temperatura foi estatisticamente significante (p<0,01) para SBU SE. Ambos os tratamentos da dentina resultaram em valores maiores de resistência adesiva para SBU no modo TE, independente da temperatura do adesivo. Já para SBU aplicado na técnica autocondicionante, apenas o jateamento com bicarbonato de sódio foi significativamente diferente quando comparado ao grupo que não recebeu tratamento. O adesivo aquecido não teve influência significativa sobre a resistência adesiva à microtração, para todos os grupos testados. As fraturas adesivas foram predominantes para todos os grupos. Dessa forma, o pré-tratamento dentinário pode ser uma alternativa para melhorar as propriedades adesivas do sistema adesivo Scotchbond Universal.
259

EFEITO DO CLAREAMENTO DENTAL NA RESISTÊNCIA DE UNIÃO DE SISTEMAS ADESIVOS AO ESMALTE / THE EFFECT OF THE TOOTH WHITENING IN BOND STRENGTH OF ADHESIVE SYSTEMS TO ENAMEL.

Steglich, Ana Guerreiro 24 July 2014 (has links)
With the increasing demand of the population for dental bleaching and concomitant evolution of adhesive systems, has increasingly sought to know more about the relationship between bleaching and esthetic restorations. Because of that this work aims to evaluate the influence of in-office bleaching challenge the bond strength of adhesive systems to dental enamel. To this were randomly divided 40 permanent human molars were divided into 4 groups (n = 10) teeth in accordance with the Single Bond (3M ESPE) and Universal Single Bond (3M ESPE) and treatment (bleaching and whitening without). The teeth were prepared and had their root surface removed in the transverse direction with diamond disk, the coronal portion was sectioned along the axis of the tooth in the mesial - distal direction, resulting in two sections, which were embedded in acrylic resin in PVC rings, the eixar mode exposed enamel surface. The smooth surfaces were ground with 600-grit sandpaper under water cooling, so you obtain a flat surface. On the surface enamel adhesive system according to the group indicated and in accordance with the manufacturers recommendations was applied and after that the adhesive was light cured for 10 seconds. After light curing of the adhesive was a cylinder made of composite resin, with dimensions of 2.0 x1, 09mm, with the aid of an all perforated starch. The specimens of groups with whitening underwent 2 sessions of office bleaching with carbamide peroxide gel 37 % with an interval of 7 days between them. After that were stored in a thermal oven at 37 º C for 24h and then the mechanical test microshear was performed to measure the bond strength. Have the groups without bleaching were stored in a thermal oven 37 º C for 24h and then subjected to testing microshear. The data relating to test microshear, expressed in MPa, were subjected to statistical analysis. The sampling distribution of the data was assumed to follow normal after completion of the Kolmogorov - Smirnov test. The values of bond strength in MPa were subjected to analysis of variance of two factors in order to check the influence of the bleaching procedure after challenge adhesive and adhesive system. The significance level for all analyzes was 5% and these were performed in Minitab 17 software (Minitab Inc., State College, PA, USA). Analysis of variance was not able to point to significant differences factors prior treatment with acid or with self-etching adhesive conditioning. As for tooth whitening there were no significant differences (p = 0.272) .Also there were no significant differences in the adhesive system employed , SBU or BSA (p = 0.187) nor for the interaction between the two factors (p = 0.758 ) . So the thooth whitening is a safe procedure in this conditions. / Com o aumento da procura da população pelo clareamento dental e concomitantemente com a evolução dos sistemas adesivos, cada vez tem se buscado mais saber sobre a relação entre o clareamento e as restaurações estéticas. Frente a isso esse trabalho tem o objetivo de avaliar a influência clareamento dental de consultório na resistência de união de sistemas adesivos ao esmalte dentário. Para isso foram divididos aleatoriamente 40 dentes molares humanos permanentes que foram distribuídos em 4 grupos (n=10), de acordo com o sistema adesivo Single Bond (3M ESPE) e Single Bond Universal (3M ESPE) e tratamento (com clareamento e sem clareamento). Os dentes foram preparados e tiveram sua superfície radicular removida no sentido transversal com disco diamantado, a porção coronária foi seccionada ao longo eixo do dente no sentido mésio-distal, resultando em duas secções, que foram embutidas em resina acrílica em anéis de PVC, a modo de deixar exposta a superfície do esmalte. As faces lisas foram abrasionadas com lixa d água de granulação 600 sob refrigeração, para que se obtivesse uma superfície plana. Sobre a superfície de esmalte foi aplicado o sistema adesivo de acordo com o grupo indicado e com as recomendações dos fabricantes e após isso o adesivo foi fotopolimerizado por 10 segundos. Após a fotopolimerização do adesivo foi confeccionado um cilindro de resina composta, com dimensões de 2,0 x 1,09 mm, com o auxílio de um tubo de amido perfurado. Os espécimes dos grupos com clareamento foram submetidos a duas sessões de clareamento de consultório com gel de peróxido de carbamida 37% com intervalo de 7 dias entre elas. Após isso foram armazenados em estufa térmica a 37º C por 24 h e então foi realizado o ensaio mecânico de microcisalhamento para mensurar a resistência de união. Já os grupos sem clareamento foram armazenados em estufa térmica 37º C por 24 h e depois submetidos a ensaio de microcisalhamento. Os dados referentes ao ensaio de microcisalhamento, expressos em MPa, foram submetidos a análise estatística. A distribuição amostral dos dados foi assumida como seguindo a normal, após a realização do teste de Kolmogorov Smirnov. Os valores de resistência de união em MPa foram submetidos a análise de variância de dois fatores a fim de verificar a influência do desafio clareador após procedimento adesivo e sistema adesivo. O nível de significância considerado em todas as análises foi de 5% e essas foram realizadas no programa Minitab 17 (Minitab Inc., State College, PA, EUA). A análise de variância não foi capaz de apontar diferenças significativas para os fatores tratamento com condicionamento ácido prévio ou com adesivo autocondicionante. Quanto ao clareamento dental não houve diferenças significativas (p=0,272). Também não houve diferenças significativas quanto ao sistema adesivo empregado, SBU ou ASB (p=0,187), nem para a interação entre os dois fatores (p=0,758). Sendo assim o clareamento dental um procedimento seguro nas condições abordadas.
260

Photoinitiated cyanoacrylates for fast underwater bonding

Cloete, William Edward 21 October 2009 (has links)
Strong underwater bonds between polycarbonate sheet and various other substrates were achieved using ethyl 2-cyanoacrylate gel cured with an anionic photoinitiator (dibenzoylferrocene). The gel reacts quickly with water on contact and forms a protective polyethyl cyanoacrylate (PECA) skin. This provides a diffusion barrier that protects the inner monomer from further reaction with or polymerisation by water (hydroxide ions). The PECA skin is, however, permeable to water and the inner monomer slowly reacts as water diffuses through the PECA skin. The application procedure for this adhesive is critical because of the fast reaction with water. The adhesive should be applied at the centre of the bond area in such a way as to cover the smallest exposed surface area and that it should not be spread out over the entire surface area. The PECA skin will rupture when the substrates are pressed together, exposing unreacted monomer to the fresh new surface between the two substrates. The adhesive displaces water as it propagates towards the joint edges. In this way it is able to form a strong underwater bond. Without a photoinitiator, ethyl cyanoacrylate adhesives will form strong bonds to smooth underwater surfaces. The addition of a photoinitiator (dibenzoylferrocene), however, increases the rate at which the bond strength develops. Photo differential scanning calorimetric (photo-DSC) analysis was used to determine the optimum photoinitiator concentration. A concentration of between 0.3% (m/m) and 0.1% (m/m) was found to be optimum for adhesive films between 0.5 and 1.2 mm thick. Epoxy-based underwater adhesives have the disadvantage that the cure rate is very slow at low water temperatures. In contrast, the current system features a negative temperature dependence. Therefore, the curing rate is faster at lower water temperatures, making it highly suitable for very cold environmental conditions. The underwater bonding properties of cyanoacrylate adhesive were measured on a wide range of metallic and non-metallic materials. Bond strengths ranged from 1 to 5 MPa respectively. Bond strength (0.2 mm film thickness) develops in a very short time (less than a minute) using a 5 mW/cm2 blue LED light source as trigger for the photo initiator. Water temperatures between 1.5 and 40 °C did not influence the ultimate bond strength achieved following 50 seconds of illumination. The reduction in bond strength due to the ethyl cyanoacrylates reacting with water was measured in artificial sea water and potable water. A 20% reduction in bond strength was found after 10 minutes of water exposure. The underwater bond should therefore be made as soon as possible following exposure to water. Bond ageing studies on both steel and polycarbonate showed an initial decrease in bond strength (during the first 50 hours); thereafter the bond strength stabilises. / Dissertation (MEng)--University of Pretoria, 2011. / Chemical Engineering / unrestricted

Page generated in 0.0436 seconds