1 |
DISTRESS AND HEALTH INFORMATION INTERESTS OF WOMEN FOLLOWING A BENIGN BREAST BIOPSYSteffens, Rachel Fancher 01 January 2008 (has links)
Benign breast biopsy (BBB) can be a stressful experience for many women. Few studies have examined the specific aspects of the BBB more and less distressing. However, no research studies have examined demographic and clinical variables as they relate to distress associated with specific aspects of the BBB or the informational interests of women following a BBB. This study evaluated the magnitude of distress associated with each aspect of the BBB (additional mammography, waiting for the results of the mammography, being informed of needing a biopsy, etc.) as well as the clinical (family history of BC in first degree relative, history of BBB, and type of biopsy) and demographic (age and education) variables as correlates of distress associated with each aspect of a BBB. Additionally, we examined health information interests in women following a BBB and the manner in which women preferred to have this health information communicated.
|
2 |
Tissue Stabilization in MRI-Guided Breast BiopsyIranpanah, Behzad 09 September 2014 (has links)
<p>Breast cancer is the most common form of cancer in women in the United States. Histopathological examination through breast biopsy is considered as the "Gold Standard" for a definitive diagnosis. Contrast-enhanced Magnetic Resonance Imaging (MRI) is often used for guiding the biopsy in those cases in which the tumor may not be detectable under Ultrasound or X-ray mammography. Stabilization of the breast tissue during the biopsy is critical for its success to ensure that the target would not be displaced due to the patient movement or tissue deformation. Conventionally, the breast tissue is immobilized by firmly compressing it between two parallel plates. However, high compression forces causes significant patient discomfort and can reduce the intake of the contrast agent, which negatively impact the image quality.</p> <p>This thesis introduces devices and control methodologies for active tissue stabilization in magnetic resonance imaging (MRI)-guided breast biopsy. Pneumatic and piezoelectric actuators have been considered for developing concept designs for MRI-compatible tissue stabilization devices. Only the pneumatic device has been prototyped and tested. The device is comprised of two pneumatically-actuated support plates that would stabilize the biopsy target movements during needle insertion. An optimized geometry for the support plates allows for a good degree of tissue stabilization without relying on large compression forces. The plate configuration can also be adjusted inside the magnet bore using pneumatic actuators driven by pressure-controlled valves that are placed in the MR control room. This capability allows for the compensation of the target displacement based on MR image feedback. When combined with a separate needle drive mechanism, this stabilization device would enable in-bore MR-guided breast biopsy in combination with an in-bore needle driver system. The proposed approach offers improved target stabilization at reduced compression force and patient discomfort, that may also enhance MR image quality as result of greater intake of contrast agent. The open-front design of the stabilization plates provides greater flexibility in selecting the needle insertion entry point, and active adjustment of the support plates based on MR feedback improves the targeting accuracy.</p> <p>A concept design for a MR-compatible needle driver mechanism using piezoelectric actuators is also proposed. Experiments performed on chicken breast tissue with a prototype of the device demonstrate the effectiveness of this mechanism in increasing needle targeting accuracy using two simple error correction strategies. Furthermore, MRI compatibility tests are carried out to asses the performance of the device inside MRI.</p> / Master of Applied Science (MASc)
|
3 |
Impacto do Mindfulness em mulheres submetidas a biópsia de mama avaliação de parâmetros quantitativos e qualitativos dos marcadores de estresse /Coelho, Bertha Andrade. January 2018 (has links)
Orientador: Agnaldo Lopes da Silva Filho / Resumo: Introdução: Anualmente milhões de mulheres em todo o mundo são rastreadas para câncer de mama, sendo que algumas delas serão submetidas a procedimentos adicionais, entre eles a biópsia mamária. A biópsia de fragmento (core biopsy) guiada por ultrassonografia é um método minimamente invasivo para o diagnóstico de lesões mamárias suspeitas, e possui inúmeras vantagens quando comparada às biópsias cirúrgicas. A core biopsy é um procedimento ambulatorial no qual raramente é necessário o uso de medicações analgésicas após o procedimento. No entanto, qualquer procedimento invasivo, por menor que seja, vem acompanhado de experiências de ansiedade, dor e medo do desconhecido. A Medicina Anti-Estresse entende que os pensamentos, sentimentos, níveis de ansiedade e capacidade de lidar com eventos estressores podem afetar a saúde e a percepção de saúde. Programas de Medicina Anti Estresse reduzem o estresse e auxiliam os praticantes a terem atitudes positivas em seu cotidiano. O objetivo deste estudo controlado e randomizado foi avaliar o impacto das intervenções baseadas em Mindfulness (MBIs) em parâmetros quantitativos e qualitativos de estresse em pacientes submetidas a biópsias de mama guiadas por imagem. Métodos: Após assinarem o consentimento informado, 82 mulheres com indicação de biópsia de mama guiada por imagem foram randomizadas em dois grupos: grupo MBI ou grupo controle de cuidados padrão. Na semana anterior à biópsia, minutos antes na sala de espera e durante o procedimento... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Introduction: Each year worldwide millions of women are screened for breast cancer and some of them will undergo additional investigations, including breast biopsy. Ultrasound guided core needle biopsy is a minimally invasive method for the diagnosis of suspected mammary lesions and has many advantages when compared to surgical biopsies. Core biopsy is an outpatient procedure and analgesic medication is rarely necessary after tissue removal. Nevertheless, any invasive procedure, however small it may be, is accompanied by experiences of anxiety, pain and fear of the unknown. Anti Stress Medicine recognizes that thoughts, feelings, levels of anxiety, and ability to cope with stressful events can affect health and health perception. Anti-Stress Medicine programs reduce stress and help practitioners to have positive attitudes in their daily lives. The purpose of this randomized controlled trial was to evaluate the impact of Mindfulness-based interventions (MBIs) on quantitative and qualitative stress parameters on patients undergoing imaging-guided breast biopsies. Methods: After giving informed consent, 82 women that needed percutaneous imaging-guided breast biopsy were randomized into two groups: MBI group or standard care control group. One week before the biopsy procedure, minutes prior to the biopsy procedure on the waiting room and during the biopsy procedure, the MBI group was exposed to audio guided meditations and relaxing music and the standard care control group receiv... (Complete abstract click electronic access below) / Doutor
|
4 |
Impacto do Mindfulness em mulheres submetidas a biópsia de mama: avaliação de parâmetros quantitativos e qualitativos dos marcadores de estresse / Mindfulness impact on women undergoing breast biopsy: evaluation of quantitative and qualitative stress markers parametersCoelho, Bertha Andrade [UNESP] 02 March 2018 (has links)
Submitted by Bertha Andrade Coelho (budcoelho@gmail.com) on 2018-04-24T15:22:24Z
No. of bitstreams: 1
Bertha Andrade Coelho IMPACTO DO MINDFULNESS EM MULHERES SUBMETIDAS A BIÓPSIA DE MAMA.pdf: 1828688 bytes, checksum: 411e3a6c3f67a774ee619b21e9f0f534 (MD5) / Approved for entry into archive by ROSANGELA APARECIDA LOBO null (rosangelalobo@btu.unesp.br) on 2018-04-26T17:07:04Z (GMT) No. of bitstreams: 1
coelho_ba_dr_bot.pdf: 1828688 bytes, checksum: 411e3a6c3f67a774ee619b21e9f0f534 (MD5) / Made available in DSpace on 2018-04-26T17:07:04Z (GMT). No. of bitstreams: 1
coelho_ba_dr_bot.pdf: 1828688 bytes, checksum: 411e3a6c3f67a774ee619b21e9f0f534 (MD5)
Previous issue date: 2018-03-02 / Introdução: Anualmente milhões de mulheres em todo o mundo são rastreadas para câncer de mama, sendo que algumas delas serão submetidas a procedimentos adicionais, entre eles a biópsia mamária. A biópsia de fragmento (core biopsy) guiada por ultrassonografia é um método minimamente invasivo para o diagnóstico de lesões mamárias suspeitas, e possui inúmeras vantagens quando comparada às biópsias cirúrgicas. A core biopsy é um procedimento ambulatorial no qual raramente é necessário o uso de medicações analgésicas após o procedimento. No entanto, qualquer procedimento invasivo, por menor que seja, vem acompanhado de experiências de ansiedade, dor e medo do desconhecido. A Medicina Anti-Estresse entende que os pensamentos, sentimentos, níveis de ansiedade e capacidade de lidar com eventos estressores podem afetar a saúde e a percepção de saúde. Programas de Medicina Anti Estresse reduzem o estresse e auxiliam os praticantes a terem atitudes positivas em seu cotidiano. O objetivo deste estudo controlado e randomizado foi avaliar o impacto das intervenções baseadas em Mindfulness (MBIs) em parâmetros quantitativos e qualitativos de estresse em pacientes submetidas a biópsias de mama guiadas por imagem. Métodos: Após assinarem o consentimento informado, 82 mulheres com indicação de biópsia de mama guiada por imagem foram randomizadas em dois grupos: grupo MBI ou grupo controle de cuidados padrão. Na semana anterior à biópsia, minutos antes na sala de espera e durante o procedimento, o grupo MBI foi exposto a meditações guiadas por áudio e músicas relaxantes e o grupo controle recebeu suporte da equipe de biópsia por meio de diálogo. As participantes preencheram questionários que avaliam depressão, ansiedade e estresse (DASS-21), dados demográficos e histórico médico, além de terem avaliado sua experiência de dor por meio de uma Escala Visual Analógica de Dor (EVA) e tiveram sua pressão arterial sistólica e diastólica, temperatura inicial e final, frequência cardíaca, saturação de oxigênio e cortisol salivar medidos. Resultados: A participação no grupo de intervenção foi associada a níveis reduzidos de estresse, pressão arterial, frequência cardíaca e saturação de oxigênio em comparação com a participação no grupo de cuidados padrão (valores de P < 0,05). Não houve diferença em relação aos níveis salivares de cortisol, temperatura periférica e percepção de dor entre os dois grupos estudados. Conclusão: Os resultados indicam que intervenções extremamente breves em Mindfuness são viáveis e aceitáveis, sugerindo que programas baseados em atenção plena podem ser benéficos para reduzir o desconforto em situações de estresse agudo. / Introduction: Each year worldwide millions of women are screened for breast cancer and some of them will undergo additional investigations, including breast biopsy. Ultrasound guided core needle biopsy is a minimally invasive method for the diagnosis of suspected mammary lesions and has many advantages when compared to surgical biopsies. Core biopsy is an outpatient procedure and analgesic medication is rarely necessary after tissue removal. Nevertheless, any invasive procedure, however small it may be, is accompanied by experiences of anxiety, pain and fear of the unknown. Anti Stress Medicine recognizes that thoughts, feelings, levels of anxiety, and ability to cope with stressful events can affect health and health perception. Anti-Stress Medicine programs reduce stress and help practitioners to have positive attitudes in their daily lives. The purpose of this randomized controlled trial was to evaluate the impact of Mindfulness-based interventions (MBIs) on quantitative and qualitative stress parameters on patients undergoing imaging-guided breast biopsies. Methods: After giving informed consent, 82 women that needed percutaneous imaging-guided breast biopsy were randomized into two groups: MBI group or standard care control group. One week before the biopsy procedure, minutes prior to the biopsy procedure on the waiting room and during the biopsy procedure, the MBI group was exposed to audio guided meditations and relaxing music and the standard care control group received supportive dialogue from the biopsy team. Participants completed questionnaires measuring depression, anxiety and stress (DASS-21), demographics, and medical history, evaluated their pain experience through a Visual Analogue Scale for Pain (VAS) and had their systolic and diastolic blood pressure, initial and final temperate, heart rate, oxygen saturation and cortisol salivary measured. Results: Participation in the mindfulness intervention group was associated with reduced levels of perceived stress, blood pressure, heart rate and oxygen saturation compared to participation in the standard care group (P values < 0.05). No difference was observed regarding salivary cortisol levels, peripheral temperature and pain perception between the two studied groups. Conclusion: Results indicate that an extremely brief mindfulness intervention is a feasible and acceptable intervention, suggesting that Mindfulness-based programs may be beneficial to reduce discomfort in acutely stressful settings.
|
5 |
Optimisation de l’angiomammographie et de l’angiotomosynthèse double-énergie / Optimization of contrast enhanced digital mammography and contrast enhanced digital breast tomosynthesisDromain, Clarisse 07 January 2015 (has links)
Objectifs : L’objectif a été de d’optimiser les protocoles d’acquisition des examens d’angiomammographie double-énergie, d’étudier la faisabilité de l’angiotomosynthèse pour la détection et la caractérisation des tumeurs mammaires, et d’étudier la faisabilité des biopsies stéréotaxiques sous guidage de l’angiomammographie. Méthodes : Une étude d’optimisation des paramètres d’acquisition de l’angiomammographie a été réalisée dans 4 situations cliniques pour lesquelles la qualité diagnostique requise des images de basse énergie et la dose totale délivrée à la patiente ne sont pas identiques. L’optimisation des paramètres d'exposition (anode/filtre, kVp, mAs) des images de basse énergie (BE) et haute énergie (HE) a été réalisée à partir d’une modélisation théorique de la chaîne d’acquisition. Une validation a été effectuée par mesures expérimentales sur des images de fantôme d’inserts d’iode. Nous avons ensuite étudié la technique d’angiotomosynthèse mammaire basée sur une approche double-énergie. Un nouveau fantôme anthropomorphique numérique du sein et de ses lésions, basé sur l’utilisation de primitives géométriques complexes et d’une technique de maillage surfacique, a été amélioré et utilisé pour évaluer les performances de l’angiomammographie optimisée, puis de l’angiotomosynthèse en comparaison à l’angiomammographie. Enfin, nous avons proposé un scénario pour la réalisation d’un examen de stéréotaxie avec injection d’un agent de contraste iodé et étudié la faisabilité de recombinaison d’image de haute et de basse énergie acquises à des temps différents de l’injection.Résultats et conclusion : Les optima des paramètres d’exposition trouvés par simulation avec les valeurs de SDNRpixel et SDNR2pixel /Dosetotale qui en résultent, ont été confirmés expérimentalement. Les valeurs de SDNR par pixel dans les images recombinées sont augmentées pour toutes les indications cliniques en comparaison à celle obtenues avec SenoBright ® (produit commercial de référence). L'impact sur la qualité de l’image de BE, évalué par des expérimentations sur fantôme CDMAM, a montré que les paramètres optimisés fournissent une détection similaire ou acceptable par rapport à la mammographie standard, à l’exception de l'indication de dépistage lorsque l’on considère les objets de très petits diamètres.L’étude de lecture humaine d’images simulées d’un fantôme anthropomorphique du sein incluant le rehaussement glandulaire physiologique et différents modèle tumoraux n’a pas montré d’augmentation significative de sensibilité de détection des acquisition 3D d’angiotomosynthèse comparativement aux acquisitions 2D d’angiomammographie. Les deux paramètres qui influençaient le plus la sensibilité était la concentration en iode des tumeurs et la densité du sein. L’angiomammographie était par ailleurs significativement plus spécifique que l’angiotomosynthèse. Une perspective d’amélioration pour l’angiotomosynthèse pourrait donc être l’utilisation d’algorithmes de reconstruction 3D spécifiques de cette modalité qui minimiseraient le bruit de reconstruction. Le scénario proposé pour la réalisation de biopsies sous guidage de l’angiomammographie, a mis en évidence deux contraintes techniques que sont l’échauffement du tube à rayons X et le surcroit de dose dû à la répétition des paires d’acquisitions en haute et basse énergies. Une des solutions envisagées a été de limiter le nombre d’acquisitions de BE. Notre étude a montré que la recombinaison d’une image HE avec une image BE acquise antérieurement modifiait le SDNR des lésions simulées comparativement à une recombinaison appariée d’images BE et HE acquises au même temps de l’injection. Ces modifications dépendaient du temps du pic de rehaussement maximal et du washout de la lésion. / Objectives: The purpose was to optimize the exposure parameters of CESM examinations, to assess the feasibility of contrast-enhanced DBT (CE-DBT) for the detection and the characterization of breast tumors, and to assess CESM-guided stereotactic biopsies. Methods: At first, we optimized the CESM exposure parameters in four different clinical applications for which different levels of average glandular dose and different low energy image quality are required. The optimization of exposure parameters (anode/filter, kVp, mAs) for low energy (LE) and high energy (HE) images at different levels of average glandular dose and different ratios between LE and total doses has been conducted using a simulator of the x-ray mammographic image chain. An experimental validation was then performed through phantom experiments. Secondly, we assessed the potential of CE-DBT based on a dual-energy approach. A new mesh-based anthropomorphic breast phantom was improved and used to evaluate the performance of CESM and then to compare CESM and CE-DBT. Finally, we evaluated the technical feasibility of CESM-guided biopsy. After identifying some technical constraints, we assessed the performance of the recombination of LE and HE images acquired at different times after injection, using simulated images of a geometric phantom with uniform texture, and simulated images of an anthropomorphic textured phantom with and without motion artifacts.Results and conclusion : For the four different clinical indications, optima found by simulation, with resulting SDNRpixel and SDNR2pixel/Dosetotal, were confirmed through real acquisition of images on phantoms. Our results indicate that the SDNR per pixel in recombined CESM images increased in all of the four clinical indications compared to recombined images obtained using SenoBright ® (commercial product used as reference). This result suggests the possibility to detect more subtle contrast enhancements and to decrease the number of false negatives found in clinical CESM examinations. The impact of a new dose allocation between LE and HE exposures was also evaluated on LE image quality. Results from CDMAM phantom experiments indicate that optimized parameters provide similar or acceptable detection compared to standard mammography, except for screening indication when considering the very small diameter objects.The human observer study on anthropomorphic phantom images, taking into account tumor and breast parenchyma enhancement, revealed that detection and characterization sensitivity of iodine-enhanced lesions are not statistically different between 2D CESM and 3D CE-DBT. The most influencing parameters for the detectability and the lesion size assessment were the lesion iodine concentration and the breast density. CESM was significantly more specific than CE-DBT. One of the assumptions to explain this result is the presence of higher noise in CE-DBT than in CESM images. A future improvement for CE-DBT could therefore be the design of a specific reconstruction algorithm minimizing reconstructed noise.With respect to CESM-guided biopsy the proposed scenario pointed out two major constraints, one related to the thermal load of the x-ray tube, the second related to the increased dose due to the repetition of LE and HE images. One proposed solution was to limit the number of LE exposures, requiring the possibility to recombined LE and HE images acquired at different injection time points. Our study showed that the recombination of a HE image with a LE image acquired earlier leads to SDNR changes compared to paired recombination. These changes are function of the enhancement time to peak and the washout of the lesion, and had a limited impact on the lesion detectability.
|
6 |
Established and suspected risk factors for breast cancer: A case-control study in Vancouver, BC and Kingston, ONPARKINSON, MATTHEW RAMCHARAN 15 August 2011 (has links)
More than half of all cases of breast cancer occur among women without any known risk factors. More research is needed on suspected risk factors in order to refine current breast cancer screening tools. The objectives of this thesis were: to determine the breast cancer risk associated with known risk factors (ethnicity, family history, breast biopsy, age at menarche, age at first birth, alcohol, HRT, and BMI), suspected risk factors (smoking, second-hand smoke exposure, smoked/grilled foods, and NSAID use), and to examine the above associations according to tumour receptor status, histologic grade, and menopausal status, with potential confounders also considered. This thesis project was conducted within the framework of the Molecular Epidemiology of Breast Cancer study, a case-control study of women in Vancouver, BC and Kingston, ON, with 1140 cases and 1169 controls recruited from 2005-2010. Information was collected from a detailed questionnaire.
Cases and controls were similar in terms of age at menarche, age at first birth, smoking history, second-hand smoke exposure, lifetime smoked/grilled food consumption, HRT, and BMI. Among cases, there were significantly less Europeans and more Chinese, Japanese, and Filipino subjects compared to controls. Cases were more likely to have a first degree relative with breast cancer, as well as a previous benign breast biopsy. Alcohol consumption and past NSAID usage was higher among controls. The level of education completed was higher among controls. Cases were also more likely to be postmenopausal.
Family history was associated with breast cancer risk (OR=1.59, CI=1.30-1.94), as was BMI (OR=1.28, CI=1.05-1.58 for overweight and OR=2.28, CI=1.35-3.86 for obese class II). Second-hand smoke was also found to be associated with breast cancer risk (OR=1.42, CI=1.02-1.97 for individuals with a less than 10 pack-year smoking history). Due to reduced sample size with stratification and marginally significant results, it is not possible to draw definitive conclusions regarding pathology sub-types.
In summary, these results provide support for the association between several risk factors and breast cancer risk. More research is needed to ascertain how receptor status, histologic grade, and menopausal status affect these associations. / Thesis (Master, Community Health & Epidemiology) -- Queen's University, 2011-08-15 19:43:06.689
|
Page generated in 0.0462 seconds