• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A modelling methodology to quantify the impact of plant anomalies on ID fan capacity in coal fired power plants

Khobo, Rendani Yaw-Boateng Sean 13 September 2020 (has links)
In South Africa, nearly 80 % of electricity is generated from coal fired power plants. Due to the complexity of the interconnected systems that make up a typical power plant, analysis of the root causes of load losses is not a straightforward process. This often leads to losses incorrectly being ascribed to the Induced Draught (ID) fan, where detection occurs, while the problem actually originates elsewhere in the plant. The focus of this study was to develop and demonstrate a modelling methodology to quantify the effects of major plant anomalies on the capacity of ID fans in coal fired power plants. The ensuing model calculates the operating point of the ID fan that is a result of anomalies experienced elsewhere in the plant. This model can be applied in conjunction with performance test data as part of a root cause analysis procedure. The model has three main sections that are integrated to determine the ID fan operating point. The first section is a water/steam cycle model that was pre-configured in VirtualPlantTM. The steam plant model was verified via energy balance calculations and validated against original heat balance diagrams. The second is a draught group model developed using FlownexSETM. This onedimensional network is a simplification of the flue gas side of the five main draught group components, from the furnace inlet to the chimney exit, characterising only the aggregate heat transfer and pressure loss in the system. The designated ID fan model is based on the original fan performance curves. The third section is a Boiler Mass and Energy Balance (BMEB) specifically created for this purpose to: (1) translate the VirtualPlant results for the steam cycle into applicable boundary conditions for the Flownex draught group model; and (2) to calculate the fluid properties applicable to the draught group based on the coal characteristics and combustion process. The integrated modelling methodology was applied to a 600 MW class coal fired power plant to investigate the impact of six major anomalies that are typically encountered. These are: changes in coal quality; increased boiler flue gas exit temperatures; air ingress into the boiler; air heater inleakage to the flue gas stream; feed water heaters out-of-service; and condenser backpressure degradation. It was inter alia found that a low calorific value (CV) coal of 14 MJ/kg compared to a typical 17 MJ/kg reduced the fan's capacity by 2.1 %. Also, having both HP FWH out of service decreased the fan's capacity by 16.2 %.
2

Study of interactions between processing capacities and language development in children with specific language impairment/ Etude des interactions entre les capacités de traitement et le développement du langage chez des enfants dysphasiques

Leclercq, Anne-Lise 18 February 2011 (has links)
Ce travail est consacré à lévaluation de lhypothèse selon laquelle une limitation des capacités de traitement est à lorigine des troubles langagiers et non langagiers des enfants dysphasiques (ou enfants avec troubles spécifiques du langage, TSL). Les enfants présentant ces troubles montrent des limitations importantes de leurs compétences langagières sans raison apparente (absence de troubles auditifs, intellectuels et affectifs ou de lésions neurologiques). Ces dernières années, la spécificité des troubles langagiers a été remise en cause par de nombreuses études révélant lexistence de difficultés non spécifiquement linguistiques chez les enfants avec TSL, tels que des troubles attentionnels, exécutifs et moteurs. Certains auteurs ont formulé l'hypothèse quune limitation des capacités de traitement est à lorigine des troubles langagiers et non langagiers des enfants avec TSL. Selon cette hypothèse, les troubles langagiers observés chez ces enfants ne sont pas dus à un déficit des représentations linguistiques, mais reflètent une performance limitée par des difficultés à mobiliser lensemble des ressources, linguistiques et/ou non linguistiques, nécessaires à la réalisation de la tâche. Les recherches réalisées ont permis dévaluer si une telle hypothèse permet dexpliquer les performances observées dans deux épreuves linguistiques considérées par plusieurs auteurs comme des marqueurs comportementaux des TSL, les traitements morphosyntaxiques et la répétition de non-mots, en manipulant les processus recrutés ou la quantité de ressources nécessaires lors de la réalisation de la tâche. Nous avons également manipulé la complexité dans une épreuve non linguistique afin détudier si les limitations des capacités de traitement peuvent être considérées comme générales ou si elles savèrent limitées aux traitements linguistiques. Globalement, nos résultats ne sont pas compatibles avec lhypothèse dune limitation des capacités de traitement à lorigine des troubles linguistiques des enfants avec TSL. Ces enfants ne présentent pas de limitation importante de leurs capacités de traitements qui permette dexpliquer leurs troubles langagiers.

Page generated in 0.1131 seconds