• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Reator de Arco Elétrico submerso em meio líquido para Síntese de Nanotubos de Carbono.

Trevisan, Luciano Schons 30 March 2009 (has links)
Submitted by MARCIA ROVADOSCHI (marciar@unifra.br) on 2018-08-14T17:19:59Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_LucianoSchonsTrevisan.pdf: 2258349 bytes, checksum: f8fa9fb772187e33211210fbbb5722df (MD5) / Made available in DSpace on 2018-08-14T17:19:59Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_LucianoSchonsTrevisan.pdf: 2258349 bytes, checksum: f8fa9fb772187e33211210fbbb5722df (MD5) Previous issue date: 2009-03-30 / This paper explain about the design and construction of an electric arc discharge reactor to synthesis of carbon nanotubes, using graphite rods as precursors. Unlike the conventional method, it uses the water into open vessel to isolate the reaction of external environment, without needing a sealed and pressurized chamber immersed in inert gas. The project is divided into three parts: mechanical, electronics and software. Preliminary tests provided initial values for the electric current applied to the graphite electrodes during the cycles of synthesis. It was performed in order to ensure the operation of electromechanical system. The samples formed in the reactor were characterized by Raman spectroscopy and Thermal Gravimetric Analysis techniques. Different types of nanostructures were observed in colected samples. The results indicated the presence of low percentage of amorphous carbon in the material formed, as well as the presence of multiple wall carbon nanotubes. The apparatus allows the easy manipulation of the parameters involved in synthesis therefore is able to promot the growth of nanostructured materials so selective and controlled. / Este trabalho aborda o projeto e a construção de um reator de arco elétrico para síntese de nanotubos de carbono, empregando como precursores bastões de grafite. Diferente do método convencional, o proposto reator utiliza água, em uma cuba aberta para garantir o isolamento da reação do meio externo dispensando com isso uma câmara selada, pressurizada e imersa em um gás inerte. O projeto divide-se em três partes: mecânica, eletrônica e o software. Testes preliminares forneceram os valores iniciais para a corrente elétrica aplicada aos eletrodos de grafite durante os ciclos de síntese que foram executados no intuito de certificar o funcionamento do conjunto eletromecânico. As amostras formadas no reator foram caracterizadas por técnicas de espectroscopia Raman e análise termo gravimétrica. Nas amostras coletadas diferentes tipos de nanoestruturas foram observadas. Os resultados indicaram a presença de baixa porcentagem de carbono amorfo junto ao material formado, assim como a presença de nanotubos de carbono de múltiplas paredes. O aparato permite a fácil manipulação dos parâmetros envolvidos na síntese, sendo assim capaz de promover o crescimento de materiais nanoestruturados de forma seletiva controlada.
2

Estudo e desenvolvimento de dosímetros luminescentes opticamente estimulados de a-Al2O3 com nanoestruturas de carbono e óxidos terras-raras para aplicação em radioterapia / Study and development of optically stimulated luminescent dosimeters of -Al2O3 with carbon nanostructures and rare-earth oxides for use in Radiotherapy

Schuch, Franciely Fernanda 17 August 2016 (has links)
A alta sensibilidade e a reprodutibilidade de sinal são características de dosímetros luminescentes opticamente estimulados, que instigam seu uso no controle da qualidade e dosimetria in vivo em Radioterapia. Nesse trabalho, amostras de Al2O3, Al2O3 (1%C) e Al2O3 com diferentes concentrações de terras-raras e de nanoestruturas de carbono foram estudadas para aplicação em Radioterapia. As amostras foram obtidas pelo processo manual de mistura e maceração e inseridas em cápsulas transparentes, com exceção do material Al2O3 (1%C), que foi obtido na forma de pastilhas. Os sinais OSL para todos os materiais testados apresentaram crescimento de resposta com a dose de radiação. A concentração de 0,02% apresentou maior intensidade de sinal para todos os materiais inseridos na alumina, com exceção do carbono grafite (1%). Os materiais foram caracterizados por diferentes técnicas, para análises espectroscópicas e estruturais. A sensibilidade OSL do material Al2O3 (1%C) foi investigada para feixes de elétrons de 5 a 12 MeV, para feixe de fótons de 6 MV e para uma fonte de Irídio-192. Diferentes características dosimétricas OSL dos materiais Al2O3 (0,02%Eu), Al2O3 (0,02%Tb), Al2O3 (0,02%ntC), Al2O3 (0,02%npC) foram investigadas para feixes de fótons de 50 kVp, de 6 MV e para uma fonte de Irídio-192, em um amplo intervalo de doses. Todos os materiais apresentaram reprodutibilidade de sinal OSL (desvios menores que 1%) e homogeneidade de resposta em grupo de até ±95% (conferida para o dosímetro de Al2O3 (0,02%ntC). Todos os materiais estudados apresentaram sensibilidade satisfatória para doses de interesse clínico. Amostras OSL de Al2O3 (1% C), Al2O3 (0,02%ntC) e Al2O3 (0,02%npC) foram utilizadas para um estudo piloto de dosimetria in vivo em Radioterapia. A dosimetria in vivo sugere o possível uso dos dosímetros na rotina clínica em Radioterapia, através do estabelecimento de um protocolo de medidas, calibrações para cada feixe e energia utilizada e controle do sistema de planejamento utilizado para os cálculos de dose. / High sensitivity and signal reproducibility are characteristics of optically stimulated luminescent dosimeter, instigating it use in quality control and in vivo dosimetry in Radiotherapy. In this work, samples of Al2O3, Al2O3 (1%C) and Al2O3 with different concentrations of rare-earth and carbon nanostructures, have been studied and developed for application in Radiotherapy. Samples were obtained by manual mixing and maceration and inserted into transparent capsules, except those of Al2O3 (1%C) which were produced as pellets. The OSL signals for all tested materials showed increasing response with radiation dose. The 0.02% concentration showed the highest signal intensity for all materials inserted into alumina, with exception to carbon graphite (1%). Materials were characterized by various techniques, through spectroscopic and structural analysis. The OSL sensitivity of Al2O3 (1%C) was investigated for electron beams from 5 to 12 MeV, 6 MV photons and an Iridium-192 source. Different dosimetric characteristics of some OSL materials Al2O3 (0.02%Eu), Al2O3 (0.02%Tb), Al2O3 (0.02%ntC), Al2O3 (0.02% npC) were investigated for photons beams of 50 kVp and 6 MV and a source of Iridium-192, in a wide dose range. All materials showed reproducibility of OSL signal (deviations less than 1%) and response homogeneity up to ± 95% (conferred for the dosimeter Al2O3 (0.02%ntC). All studied materials showed satisfactory sensitivity. Samples of Al2O3 (1%C), Al2O3 (0.02%ntC) and Al2O3 (0.02% npC) were used in a in vivo dosimetry pilot study in radiotherapy. The in vivo dosimetry performed with the developed OSL dosimeters suggest its possible use in clinical practice in Radiotherapy by establishing a measure protocol, calibrations for each beam and energy used and control of the planning system used for dose calculations.
3

Estudo e desenvolvimento de dosímetros luminescentes opticamente estimulados de a-Al2O3 com nanoestruturas de carbono e óxidos terras-raras para aplicação em radioterapia / Study and development of optically stimulated luminescent dosimeters of -Al2O3 with carbon nanostructures and rare-earth oxides for use in Radiotherapy

Franciely Fernanda Schuch 17 August 2016 (has links)
A alta sensibilidade e a reprodutibilidade de sinal são características de dosímetros luminescentes opticamente estimulados, que instigam seu uso no controle da qualidade e dosimetria in vivo em Radioterapia. Nesse trabalho, amostras de Al2O3, Al2O3 (1%C) e Al2O3 com diferentes concentrações de terras-raras e de nanoestruturas de carbono foram estudadas para aplicação em Radioterapia. As amostras foram obtidas pelo processo manual de mistura e maceração e inseridas em cápsulas transparentes, com exceção do material Al2O3 (1%C), que foi obtido na forma de pastilhas. Os sinais OSL para todos os materiais testados apresentaram crescimento de resposta com a dose de radiação. A concentração de 0,02% apresentou maior intensidade de sinal para todos os materiais inseridos na alumina, com exceção do carbono grafite (1%). Os materiais foram caracterizados por diferentes técnicas, para análises espectroscópicas e estruturais. A sensibilidade OSL do material Al2O3 (1%C) foi investigada para feixes de elétrons de 5 a 12 MeV, para feixe de fótons de 6 MV e para uma fonte de Irídio-192. Diferentes características dosimétricas OSL dos materiais Al2O3 (0,02%Eu), Al2O3 (0,02%Tb), Al2O3 (0,02%ntC), Al2O3 (0,02%npC) foram investigadas para feixes de fótons de 50 kVp, de 6 MV e para uma fonte de Irídio-192, em um amplo intervalo de doses. Todos os materiais apresentaram reprodutibilidade de sinal OSL (desvios menores que 1%) e homogeneidade de resposta em grupo de até ±95% (conferida para o dosímetro de Al2O3 (0,02%ntC). Todos os materiais estudados apresentaram sensibilidade satisfatória para doses de interesse clínico. Amostras OSL de Al2O3 (1% C), Al2O3 (0,02%ntC) e Al2O3 (0,02%npC) foram utilizadas para um estudo piloto de dosimetria in vivo em Radioterapia. A dosimetria in vivo sugere o possível uso dos dosímetros na rotina clínica em Radioterapia, através do estabelecimento de um protocolo de medidas, calibrações para cada feixe e energia utilizada e controle do sistema de planejamento utilizado para os cálculos de dose. / High sensitivity and signal reproducibility are characteristics of optically stimulated luminescent dosimeter, instigating it use in quality control and in vivo dosimetry in Radiotherapy. In this work, samples of Al2O3, Al2O3 (1%C) and Al2O3 with different concentrations of rare-earth and carbon nanostructures, have been studied and developed for application in Radiotherapy. Samples were obtained by manual mixing and maceration and inserted into transparent capsules, except those of Al2O3 (1%C) which were produced as pellets. The OSL signals for all tested materials showed increasing response with radiation dose. The 0.02% concentration showed the highest signal intensity for all materials inserted into alumina, with exception to carbon graphite (1%). Materials were characterized by various techniques, through spectroscopic and structural analysis. The OSL sensitivity of Al2O3 (1%C) was investigated for electron beams from 5 to 12 MeV, 6 MV photons and an Iridium-192 source. Different dosimetric characteristics of some OSL materials Al2O3 (0.02%Eu), Al2O3 (0.02%Tb), Al2O3 (0.02%ntC), Al2O3 (0.02% npC) were investigated for photons beams of 50 kVp and 6 MV and a source of Iridium-192, in a wide dose range. All materials showed reproducibility of OSL signal (deviations less than 1%) and response homogeneity up to ± 95% (conferred for the dosimeter Al2O3 (0.02%ntC). All studied materials showed satisfactory sensitivity. Samples of Al2O3 (1%C), Al2O3 (0.02%ntC) and Al2O3 (0.02% npC) were used in a in vivo dosimetry pilot study in radiotherapy. The in vivo dosimetry performed with the developed OSL dosimeters suggest its possible use in clinical practice in Radiotherapy by establishing a measure protocol, calibrations for each beam and energy used and control of the planning system used for dose calculations.
4

DESENVOLVIMENTO DE DIFERENTES DISPOSITIVOS ELETROQUÍMICOS A BASE DE OURO APLICADOS COMO SENSORES E BIOSSENSORES

Santos, Cleverson Siqueira 06 May 2016 (has links)
Made available in DSpace on 2017-07-20T12:40:17Z (GMT). No. of bitstreams: 1 Cleverson Santos.pdf: 2904178 bytes, checksum: 85140c2fc4cb486fe6c03e6a011296a3 (MD5) Previous issue date: 2016-05-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This thesis describes the preparation, characterization and application of electrochemical sensors and biosensors, using different modification techniques, based on Au as transducer. The enzymatic biosensor applied on the detection of pesticide carbaryl was built on a gold electrode functionalized with a monolayer of polyamidoamine dendrimer of fourth generation with a cystamine core (PAMAM-G4) on which it was immobilized the acetylcholinesterase enzyme (AChE), with the aid of glutaraldehyde. After evaluate and determine the best conditions for immobilization of the AChE enzyme (glutaraldehyde concentration of 1% (v/v) and the concentration of enzyme units 496 U. mL-1) on the monolayer of PAMAM, the catalytic activity of the enzyme was evaluated by chronoamperometry in presence of enzymatic substrate AChI obtaining = 2.9 . −1 . The biosensor response for carbaryl detection was based on the inhibition of the enzymatic activity caused by the pesticide. It was verified that 5 min in the pesticide solution is sufficient to block the enzyme active sites. After determining the best conditions for the construction of the biosensor, it was applied for carbaryl detection in the concentration range from 1.0 to 9.0 mol. L-1. The detection and quantification limits were found to be 0.0108 mol. L-1 and 0.032 mol. L-1, respectively. In the second chapter, it is reported the development of an immunosensor applied to qualitative detection of antibodies (AB) T. cruzi. The sensor was built on gold electrode modified with the thiol 3-mercaptopropionic acid (MPA) and the antigens (AG) T. cruzi were covalently immobilized on this surface by the reaction with EDC and NHS. The influence of concentration and of immersion time in the AG solution were evaluated using the techniques of cyclic voltammetry and electrochemical impedance spectroscopy in presence of [Fe(CN)6]3-/4- and the results showed that the best conditions were immersion time of 15 minutes and AG concentration of 0.5 g. L-1.The possible sites of non-specific binding were blocked with bovine serum albumin (BSA). The immersion time in the solution (AB) was also evaluated and the results showed that 30 minutes are sufficient for all specific bonds sites were occupied by AB T. cruzi. Selectivity tests in the absence of AB, only in the serum sample, and in the presence of AB Toxoplasma were performed. The results demonstrated that the immunosensor is selective, since it presented charge transfer resistance (Rct) values in the presence of AB T. cruzi 70% higher than the Rct values in presence of possible interferences.Therefore, the immunosensor presents itself as an alternative to qualitative diagnosis of american trypanosomiasis. In the third chapter, it is reported the modification of carbon graphite electrodes (CG) obtained from dry batteries zinc/carbon with Au microparticles obtained by potentiostatic electrodeposition. The variables involved in the electrodeposition process, such as the gold salt concentration, time and deposition potential were evaluated and optimized using cyclic voltammetry technique in the presence of redox couple [Fe(CN)6]3-/4-. The best conditions for the Au deposition were electrodeposition time of 700 s, potential of +0.3 V and concentration of 10.0 mmol. L-1. In these conditions, Au spherical particles were obtained with an average size of 420 nm, which were homogeneously deposited on the surface of GC electrode and promoted the increase of the electroactive area (GC electrode showed an area of 0.12 cm2 and GC/Au electrode presented an area of 0.25 cm2). The GC/Au electrode was applied for the separation and quantification of dopamine and uric acid present in a mixture. The voltammetric results showed that the GC/Au sensor is selective, once the potential peak separation between the DA and UA species was 370 mV. The detection and quantification limits were found to be 1.86 mol. L-1 and 6.09 mol. L-1 for dopamine and uric acid 17.5 mol. L-1 and 58.5 mol. L-1, respectively. In the development of the three electrochemical devices gold electrodes were used. From the results obtained for the three developed electrochemical devices it can be concluded that high electric conductivity, chemical stability, biocompatibility, ability to miniaturization in the form of microstructures and ease of functionalization of Au electrodes make them suitable conductive matrixes for construction of electrochemical sensors and particularly biosensors. / Esta tese descreve a preparação, caracterização e aplicação de sensores e biossensores eletroquímicos, utilizando diferentes técnicas de modificação baseadas no Au como transdutor. O biossensor enzimático aplicado na detecção do pesticida carbaril foi construído sobre um eletrodo de ouro funcionalizado com uma monocamada do dendrímero poliamidoamina de quarta geração com núcleo de cistamina (PAMAMG4),sobre o qual foi imobilizada com o auxílio de glutaraldeído a enzima acetilcolinesterase (AChE).Após avaliar e determinar as melhores condições de imobilização da enzima AChE (concentração de GLUT 1% (v/v) e concentração de unidades enzimáticas 496 U. mL-1) sobre a monocamada de PAMAM,a atividade catalítica da enzima AChE imobilizada foi avaliada por cronoamperometria na presença do substrato enzimático (AChI) obtendo-se o = 2,9 . −1. A resposta do biossensor na detecção de carbaril foi baseada na inibição da atividade enzimática causada pelo pesticida. Foi constatado que 5 min de imersão na solução do pesticida foram suficientes para que os sítios ativos da enzima fossem bloqueados. Após determinar as melhores condições de construção do biossensor, este foi aplicado na detecção de carbaril na faixa de 1,0 a 9,0 mol. L-1. Os limites de detecção e quantificação encontrados foram de 0,0108 mol. L-1 e 0,032 mol. L-1, respectivamente. No segundo capítulo é relatado o desenvolvimento de um imunossensor aplicado na detecção qualitativa de anticorpos (AB) T. cruzi. O sensor foi construído sobre eletrodo de ouro modificado com o tiol ácido 3-mercaptopropiônico (MPA) e sobre esta superfície foram imobilizados covalentemente pela reação com EDC e NHS, os antígenos (AG) T. cruzi. A influência da concentração da solução de AG e do tempo de imersão nesta solução para a construção do imunossensor foram avaliadas utilizando as técnicas de voltametria cíclica e espectroscopia de impedância eletroquímica na presença de [Fe(CN)6]3-/4- e os resultados demonstraram que as melhores condições foram: tempo de 15 min e concentração de 0,5 g. L-1. Os possíveis sítios de ligações não específicas foram bloqueados com albumina de soro bovino (BSA). O tempo de imersão na solução de AB também foi avaliado. Os resultados mostraram que 30 min são suficientes para que todos os sítios de ligações específicos fossem ocupados pelos AB T. cruzi. Testes de seletividade na ausência de AB,apenas em amostra de soro e também na presença de AB de Toxoplasma foram realizados. Os resultados demonstraram que o imunossensor é seletivo, pois este apresentou valores de resistência de transferência de carga (Rct) na detecção de AB T. cruzi 70% maiores do que na detecção dos possíveis interferentes. Portanto, o imunossensor apresenta-se como uma alternativa no diagnóstico qualitativo de tripanossomíase americana. No terceiro capítulo é descrito a modificação de eletrodos de carbono grafite (CG) obtidos de pilhas secas de zinco/carbono com micropartículas de Au obtidas pela eletrodeposição potenciostática. As variáveis envolvidas no processo de eletrodeposição, tais como concentração do sal de ouro, potencial e tempo de deposição foram avaliadas e otimizadas utilizando a técnica de voltametria cíclica na presença do par redox [Fe(CN)6]3-/4-. As melhores condições foram: tempo de 700 s, potencial de +0,3 V e concentração de 10,0 mmol. L-1. Nestas condições, foram obtidas partículas de Au esféricas com tamanho médio de 420 nm, as quais se apresentaram homogeneamente dispersas sobre toda a superfície do eletrodo de CG e promoveram o aumento da área eletroativa, (o eletrodo CG apresentou uma área de 0,12 cm2 e o eletrodo CG/Au uma área 0,25 cm2). O desempenho do eletrodo CG/Au foi avaliado na separação e quantificação de dopamina e ácido úrico presentes em uma mistura. Os resultados voltamétricos demonstraram que o sensor CG/Au é seletivo, pois apresentou separação de potencial pico de 370 mV entre as duas espécies. Os limites de detecção e quantificação encontrados foram de 1,86 mol. L-1 e 6,09 mol. L-1 para dopamina, e 17,5 mol. L-1 e 58,5 mol. L-1 para ácido úrico, respectivamente. A partir dos resultados obtidos para os três dispositivos eletroquímicos desenvolvidos pode-se concluir que a elevada condutividade elétrica, estabilidade química, biocompatibilidade, possibilidade de miniaturização na forma de microestruturas e a facilidade de funcionalização dos eletrodos de Au fazem destes matrizes condutoras apropriadas para construção de sensores e particularmente biossensores eletroquímicos.

Page generated in 0.0645 seconds